TY - JOUR A1 - Cervino, C. A1 - Knopp, D. A1 - Weller, Michael G. A1 - Niessner, R. T1 - Novel Aflatoxin derivatives and protein conjugates N2 - Aflatoxins, a group of structurally related mycotoxins, are well known for their toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein conjugates are needed for diverse analytical applications. This work describes a reliable and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine serum albumin conjugates were prepared and characterised by UV absorption and MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens for the generation of aflatoxin selective antibodies with novel specificities. KW - Aflatoxin KW - Mycotoxin KW - Hapten KW - Protein conjugation KW - Immunogen KW - Antigen KW - Antibody PY - 2007 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-147572 UR - http://www.mdpi.org/molecules/papers/12030641.pdf UR - http://www.mdpi.org/molecules/papers/12030641sm.pdf DO - https://doi.org/10.3390/12030641 SN - 1420-3049 VL - 12 IS - 3 SP - 641 EP - 653 PB - MDPI CY - Basel AN - OPUS4-14757 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gaebler, A. A1 - Moessinger, A. A1 - Goelden, F. A1 - Manabe, A. A1 - Goebel, M. A1 - Follmann, R. A1 - Koether, D. A1 - Modes, C. A1 - Kipka, A. A1 - Deckelmann, M. A1 - Rabe, Torsten A1 - Schulz, Bärbel A1 - Kuchenbecker, Petra A1 - Lapanik, A. A1 - Mueller, S. A1 - Haase, W. A1 - Jakoby, R. T1 - Liquid crystal-reconfigurable antenna concepts for space applications at microwave and millimeter waves N2 - Novel approaches of tunable devices for millimeter wave applications based on liquid crystal (LC) are presented. In the first part of the paper, a novel concept of a tunable LC phase shifter realized in Low Temperature Cofired Ceramics technology is shown while the second part of the paper deals with a tunable high-gain antenna based on an LC tunable reflectarray. The reflectarray features continuously beam scanning in between ±25°. Also first investigations on radiation hardness of LCs are carried out, indicating that LCs might be suitable for space applications. KW - Tunable antenna KW - Phase shifter KW - Liquid crystal KW - LTCC PY - 2009 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-194273 DO - https://doi.org/10.1155/2009/876989 SN - 1687-5877 VL - 2009 IS - Article ID 876989 SP - 1 EP - 7 PB - Hindawi Publishing Corporation CY - New York, NY, USA AN - OPUS4-19427 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ruibal, C. A1 - Gueidan, C. A1 - Selbmann, L. A1 - Gorbushina, Anna A1 - Crous, P.W. A1 - Groenewald, J.Z. A1 - Muggia, L. A1 - Grube, M. A1 - Isola, D. A1 - Schoch, C.L. A1 - Staley, J.T. A1 - Lutzoni, F. A1 - De Hoog, G.S. T1 - Phylogeny of rock-inhabiting fungi related to Dothideomycetes N2 - The class Dothideomycetes (along with Eurotiomycetes) includes numerous rock-inhabiting fungi (RIF), a group of ascomycetes that tolerates surprisingly well harsh conditions prevailing on rock surfaces. Despite their convergent morphology and physiology, RIF are phylogenetically highly diverse in Dothideomycetes. However, the positions of main groups of RIF in this class remain unclear due to the lack of a strong phylogenetic framework. Moreover, connections between rock-dwelling habit and other lifestyles found in Dothideomycetes such as plant pathogens, saprobes and lichen-forming fungi are still unexplored. Based on multigene phylogenetic analyses, we report that RIF belong to Capnodiales (particularly to the family Teratosphaeriaceae s.l.), Dothideales, Pleosporales, and Myriangiales, as well as some uncharacterised groups with affinities to Dothideomycetes. Moreover, one lineage consisting exclusively of RIF proved to be closely related to Arthoniomycetes, the sister class of Dothideomycetes. The broad phylogenetic amplitude of RIF in Dothideomycetes suggests that total species richness in this class remains underestimated. Composition of some RIF-rich lineages suggests that rock surfaces are reservoirs for plant-associated fungi or saprobes, although other data also agree with rocks as a primary substrate for ancient fungal lineages. According to the current sampling, long distance dispersal seems to be common for RIF. Dothideomycetes lineages comprising lichens also include RIF, suggesting a possible link between rock-dwelling habit and lichenisation. KW - Arthoniomycetes KW - Capnodiales KW - Dothideomycetes KW - Evolution KW - Extremotolerance KW - Multigene phylogeny KW - Rock-inhabiting fungi PY - 2009 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-219821 DO - https://doi.org/10.3114/sim.2009.64.06 SN - 0166-0616 VL - 64 IS - 1 SP - 123 EP - 133 PB - Centraalbureau voor Schimmelcultures CY - Utrecht, The Netherlands AN - OPUS4-21982 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kannengießer, Thomas A1 - Kromm, Arne T1 - Formation of welding residual stresses in low transformation temperature (LTT) materials N2 - For the safety and cost efficiency of welded high-strength steel structures, precise knowledge of the level and distribution of welding- and cooling-specific stresses and residual stresses is essential, since they exert a decisive influence on strength, crack resistance, and finally on the bearable service load. This paper presents innovative filler materials, of which the phase transformation temperature was deliberately adjusted via the chemical composition. The transformation behaviour of these martensitic Low Transformation Temperature (LTT-) filler materials shows direct effects on the local residual stresses in the weld and the HAZ. These effects can purposefully be exploited to counteract the thermally induced shrinkage of the material and to produce significant compressive residual stresses in the weld. Comparative welding experiments were carried out on 690 MPa high-strength base materials using various LTT-filler materials. High energy synchrotron radiation was used for residual stress measurement. Particularly the use of high energy synchrotron radiation makes it possible to detect the residual stress condition fast without destruction of material. Thereby, residual stress depth gradients can be determined simultaneously without removing material. In steel, gradients of up to 150 µm can be resolved in such a way. Furthermore, the application of high energy radiation permits determination of residual stresses of any available residual austenite contents. Results show significant dependence of transformation temperatures on the resulting residual stress level and distribution. KW - Phase specific residual stresses KW - Phase transformation KW - Low transformation temperature filler wire KW - Energy dispersive diffraction KW - High strength steel PY - 2009 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-205909 DO - https://doi.org/10.1590/S0104-92242009000100009 SN - 0104-9224 SN - 1980-6973 VL - 14 IS - 1 SP - 74 EP - 81 PB - Associação Brasileira de Soldagem, ABS CY - Rio de Janeiro AN - OPUS4-20590 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kromm, Arne A1 - Kannengießer, Thomas T1 - In-situ-phase analysis using synchrotron radiation of low transformation temperature (LTT) welding material N2 - Cold cracking resistance is a relevant evaluation criterion for welded joints and affected by residual stresses which result from the welding procedure. Compressive residual stresses can thereby have a positive influence on preventing cracking. A unique possibility of generating compressive residual stresses already during the welding procedure is offered by the so-called Low Transformation Temperature (LTT) filler wires. Compared to conventional wires, these materials show decreased phase transformation temperatures which can work against the cooling-specific contraction. In consequence, distinct compressive residual stresses can be observed within the weld and adjacent areas. The strength of these fillers makes them potentially applicable to high-strength steel welding. Investigations were carried out to determine the phase transformation behaviour of different LTT-filler materials. Transformation temperatures were identified using Single Sensor Differential Thermal Analysis (SS-DTA). Additionally Synchrotron radiation was used to measure the transformation kinetics of all involved crystalline phases during heating and cooling of a simulated weld thermal cycle. KW - In-situ phase analysis KW - Energy dispersive diffraction KW - Phase transformation KW - Low Transformation Temperature filler wire PY - 2009 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-205922 DO - https://doi.org/10.1590/S0104-92242009000100010 SN - 0104-9224 SN - 1980-6973 VL - 14 IS - 1 SP - 82 EP - 88 PB - Associação Brasileira de Soldagem, ABS CY - Rio de Janeiro AN - OPUS4-20592 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shokouhi, Parisa A1 - Zoëga, Andreas A1 - Wiggenhauser, Herbert T1 - Nondestructive investigation of stress-induced damage in concrete N2 - The changes in the sonic surface wave velocity of concrete under stress were investigated in this paper. Surface wave velocities at sonic frequency range were measured on a prismatic concrete specimen undergoing several cycles of uniaxial compression. The loading was applied (or removed) gradually in predefined small steps (stress-controlled). The surface wave velocity was measured at every load step during both loading and unloading phases. Acoustic Emission (AE) test was conducted simultaneously to monitor the microcracking activities at different levels of loading. It was found that the sonic surface wave velocity is highly stress dependent and the velocity-stress relationship follows a particular trend. The observed trend could be explained by a combination of acoustoelasticity and microcracking theories, each valid over a certain range of applied stresses. Having measured the velocities while unloading, when the material suffers no further damage, the effect of stress and damage could be differentiated. The slope of the velocity-stress curves over the elastic region was calculated for different load cycles. This quantity was normalized to yield a dimensionless nonlinear parameter. This parameter generally increases with the level of induced damage in concrete. KW - Nondestructive testing (NDT) KW - Surface wave velocity KW - Concrete KW - Acoustoelasticity KW - Microcracking PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-215943 UR - http://downloads.hindawi.com/journals/ace/2010/740189.pdf DO - https://doi.org/10.1155/2010/740189 SN - 1687-8094 SN - 1687-8086 VL - 2010 IS - Article ID 740189 SP - 1 EP - 9 PB - Hindawi Publ. Corp. CY - New York, NY, USA AN - OPUS4-21594 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schartel, Bernhard T1 - Phosphorus-based flame retardancy mechanisms - Old hat or a starting point for future development? N2 - Different kinds of additive and reactive flame retardants containing phosphorus are increasingly successful as halogen-free alternatives for various polymeric materials and applications. Phosphorus can act in the condensed phase by enhancing charring, yielding intumescence, or through inorganic glass formation; and in the gas phase through flame inhibition. Occurrence and efficiency depend, not only on the flame retardant itself, but also on its interaction with pyrolysing polymeric material and additives. Flame retardancy is sensitive to modification of the flame retardant, the use of synergists/adjuvants, and changes to the polymeric material. A detailed understanding facilitates the launch of tailored and targeted development. KW - Fire retardancy KW - Red phosphorus KW - Phosphate KW - Phosphonate KW - Phosphinate KW - Phosphine oxide KW - Flame inhibition KW - Charring KW - Intumescence PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-220368 DO - https://doi.org/10.3390/ma3104710 SN - 1996-1944 VL - 3 IS - 10 SP - 4710 EP - 4745 PB - MDPI CY - Basel AN - OPUS4-22036 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Moreira, E.V. A1 - Rabello, J.M.B. A1 - Pereira, M.d.S. A1 - Lopes, R.T. A1 - Zscherpel, Uwe T1 - Digital radiography using digital detector arrays fulfills critical applications for offshore pipelines N2 - Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines. KW - Zerstörungsfreie Prüfung von Schweißnähten KW - Durchstrahlungsprüfung KW - Digitale Radiologie PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-225319 DO - https://doi.org/10.1155/2010/894643 SN - 1687-6172 VL - 2010 IS - Article ID 894643 SP - 1 EP - 7 PB - Hindawi Publ. CY - New York, NY, USA AN - OPUS4-22531 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tölle, Florian A1 - Gumenyuk, Andrey A1 - Gebhardt, Moritz Oliver A1 - Rethmeier, Michael T1 - Post-weld residual stress mitigation by scanning of a defocused laser beam N2 - High welding residual stresses can cause service life reducing consequences. Even though many processes have been developed to reduce these stresses, they are only applicable for wider welds and simple component geometries or are cost-intensive, respectively. The presented method uses a defocused beam after welding for heating the material regions on both sides of the weld. In this way, the welding stresses are decreased without contacting the surfaces using the available equipment. Different process parameters could be used depending on the component geometry and the laser power. The mechanism and the influence of the process parameters were investigated by FEM-simulation and experiments on S355J2+N steel and showed a stress reduction of about 73%. T2 - Lasers in Manufacturing 2011 - Proceedings of the Sixth International WLT Conference on Lasers in Manufacturing CY - Munich, Germany DA - 23.05.2011 KW - Residual stresses KW - Stress reduction KW - High energy beam welding KW - Post-weld heat treatment KW - Laser scanner optics PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-238482 DO - https://doi.org/10.1016/j.phpro.2011.03.052 SN - 1875-3892 VL - 12 IS - 1 SP - 410 EP - 418 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-23848 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wolf, S. A1 - McMahon, Dino Peter A1 - Lim, K.S. A1 - Pull, C.D. A1 - Clark, S.J. A1 - Paxton, R.J. A1 - Osborne, J.L. T1 - So near and yet so far: harmonic radar reveals reduced homing ability of Nosema infected honeybees N2 - Pathogens may gain a fitness advantage through manipulation of the behaviour of their hosts. Likewise, host behavioural changes can be a defence mechanism, counteracting the impact of pathogens on host fitness. We apply harmonic radar technology to characterize the impact of an emerging pathogen - Nosema ceranae (Microsporidia) - on honeybee (Apis mellifera) flight and orientation performance in the field. Honeybees are the most important commercial pollinators. Emerging diseases have been proposed to play a prominent role in colony decline, partly through sub-lethal behavioural manipulation of their hosts. We found that homing success was significantly reduced in diseased (65.8%) versus healthy foragers (92.5%). Although lost bees had significantly reduced continuous flight times and prolonged resting times, other flight characteristics and navigational abilities showed no significant difference between infected and non-infected bees. Our results suggest that infected bees express normal flight characteristics but are constrained in their homing ability, potentially compromising the colony by reducing its resource inputs, but also counteracting the intra-colony spread of infection. We provide the first high-resolution analysis of sub-lethal effects of an emerging disease on insect flight behaviour. The potential causes and the implications for both host and parasite are discussed. PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-328827 DO - https://doi.org/10.1371/journal.pone.0103989 SN - 1932-6203 VL - 9 IS - 8 SP - e103989, 1 EP - 15 PB - PubMed Central AN - OPUS4-32882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Christina A1 - Zorn, R. A1 - Frick, B. A1 - Schönhals, Andreas T1 - Quasi- and inelastic neutron scattering to investigate the molecular dynamics of discotic molecules in the bulk N2 - In- and quasielastic neutron scattering is employed to investigate both the vibrational density of states and the molecular dynamics of two homologous discotic liquid crystals (DLC) with different length of the alkyl side chain based on a triphenylene derivate. For both compounds characteristic low frequency excess contributions to the vibrational density of states are found. Therefore it is concluded that these liquid crystals show a glass-like behaviour. Elastic scans further show that in these materials a rich molecular dynamics takes place. T2 - QENS/WINS 2014 - 11th International Conference on Quasielastic Neutron Scattering and 6th International Workshop on Inelastic Neutron Spectrometers CY - Autrans, France DA - 2014-05-11 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-325477 DO - https://doi.org/10.1051/epjconf/20158302017 SN - 2100-014X VL - 83 SP - 02017-1 EP - 02017-4 PB - EDP Sciences CY - Les Ulis AN - OPUS4-32547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mirtschin, Nikolaus A1 - Pretsch, Thorsten T1 - Designing temperature-memory effects in semicrystalline polyurethane N2 - Temperature-memory polymers are able to generate a substantial mechanical response when heated above the temperature, at which a preceding deformation was carried out. Here we show how to design the temperature-memory effect (TME) by thermomechanical treatment. As a model polymer, phase segregated poly(ester urethane) (PEU) containing crystallizable segments of poly(1,4-butylene adipate) (PBA) was used. For programming, strain elongation was applied at temperatures within the PBA melting transition area, before temperature holding, unloading and cooling were carried out. Upon heating under stress-free or constant strain recovery conditions, precisely set temperature-memory onsets could be witnessed. Most importantly, strain fixities and recoverabilities the same as maximum recovery stresses turned out to be controllable by strain rate and temperature holding time after deformation, while transition temperatures remained largely unaffected. The tailoring of thermoresponsiveness was structurally enabled by different PBA crystallinities in the programmed state as verified by wide-angle X-ray scattering (WAXS). The reported studies intend to design TMEs in semicrystalline polyurethanes according to user-defined needs to make this technology broadly applicable. KW - Poly(ester urethane) KW - Shape memory polymer KW - Temperature-memory effect KW - Thermo-responsiveness KW - Temperature-memory polymer KW - Programming KW - Thermomechanical properties PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-332856 DO - https://doi.org/10.1039/c5ra05492c SN - 2046-2069 VL - 5 IS - 57 SP - 46307 EP - 46315 PB - RSC Publishing CY - London AN - OPUS4-33285 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Cotic, P. A1 - Niederleithinger, Ernst A1 - Stoppel, Markus T1 - Unsupervised fusion of scattered data collected by a multi-sensor robot on concrete N2 - At BAM a multi-sensor robot system BetoScan is used for the investigation of reinforced concrete floors affected by corrosion in parking garages. Potential maps, as well as the distribution of concrete cover and moisture can be assessed simultaneously and data can be collected contactlessly. In order to evaluate the extent of degradation adequately and to divide the investigated structure into zones with defined damage classes, large data sets have to be collected and interpreted manually. Thus, to promote an efficient data evaluation framework, which could speed up and simplify the evaluation of large data sets, an unsupervised data fusion is of major interest. However, taking into account that collected data do not certainly coincide in space, a scattered data interpolation method should be applied prior data fusion. In the paper, a case study involving a BetoScan data set acquired from a reinforced concrete floor of a parking garage in Germany is presented. The data set includes potential mapping, covermeter based on eddy current, as well as microwave moisture measurements. Among the examined methods for interpolation of scattered data, kriging shows to yield smooth interpolated data plots even in the case of very sparse data. In the post-processing step, the investigated structure is efficiently segmented into zones using clustering based data fusion methods, which prove to be robust enough also for handling noisy data. Based on the minimization of the XB validity index, an unsupervised selection of optimal segmentation into damage classes is derived. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Robot KW - Data fusion KW - Ultrasonics KW - Radar KW - Potential method PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-337943 UR - http://www.ndt.net/article/dgzfp2014/papers/di2c1.pdf SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Di.2.C.1, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-33794 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Douma, J. A1 - Niederleithinger, Ernst A1 - Snieder, R. T1 - Improved focusing using deconvolution within a concrete block N2 - Time reversal techniques are used in ocean acoustics, medical imaging and non-destructive evaluation to backpropagate recorded signals to the source of origin. We demonstrate experimentally a technique which improves the temporal focus achieved at the source location. The experiment consists of propagating a signal from a transducer within a concrete block to a single receiver on the surface, and then applying time reversal or deconvolution to focus the energy back at the source location. The results show that we are able to generate a focus in time at the correct location. The proposed method is simple and proven to be robust. Additionally, its costs are negligible due to deconvolution being a preprocessing step to the recorded data. The technique can be applied for detailed investigation of the source mechanisms (e. g. cracks) but also for monitoring purposes. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Ultrasonics KW - Acoustic emission KW - Time reversal KW - Deconvolution PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-337953 UR - http://www.ndt.net/article/dgzfp2014/papers/di2c2.pdf SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Di.2.C.2, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-33795 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klykov, Oleg A1 - Weller, Michael G. T1 - Quantification of N-hydroxysuccinimide and N-hydroxysulfosuccinimide by hydrophilic interaction chromatography (HILIC) N2 - N-Hydroxysuccinimide (NHS) esters are the most important activated esters used in many different bioconjugation techniques, such as protein labelling by fluorescent dyes and enzymes, surface activation of chromatographic supports, microbeads, nanoparticles, and microarray slides, and also in the chemical synthesis of peptides. Usually, reactions with NHS esters are very reliable and of high yield, however, the compounds are sensitive to air moisture and water traces in solvents. Therefore, the quantification of NHS would be a very helpful approach to identify reagent impurities or degradation of stored NHS esters. No robust and sensitive method for the detection of NHS (or the more hydrophilic sulfo-NHS) has been reported yet. Here, a chromatographic method based on HILIC conditions and UV detection is presented, reaching a detection limit of about 1 mg L-1, which should be sensitive enough for most of the applications mentioned above. Exemplarily, the hydrolytic degradation of a biotin-NHS ester and a purity check of a fluorescent dye NHS ester are shown. An important advantage of this approach is its universality, since not the structurally variable ester compound is monitored, but the constant degradation product NHS or sulfo-NHS, which avoids the necessity to optimize the separation conditions and facilitates calibration considerably. KW - NHS KW - Sulfo-NHS KW - NHS-Ester KW - Qualitätskontrolle KW - Reinheitsbestimmung KW - HPLC PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-337833 DO - https://doi.org/10.1039/c5ay00042d SN - 1759-9660 SN - 1759-9679 VL - 7 IS - 15 SP - 6443 EP - 6448 PB - RSC Publ. CY - Cambridge AN - OPUS4-33783 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Siebler, Daniel A1 - Rohwetter, Philipp A1 - Brusenbach, R. A1 - Plath, R. T1 - Optical-only detection of partial discharge with fluorescent polymer optical fiber sensors N2 - This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position. T2 - EUROSENSORS 2015 CY - Freiburg, Germany DA - 06.09.2015 KW - Partial discharge KW - Silicone rubber KW - High voltage cable accessories KW - Polymer optical fiber POF KW - Fluorescence KW - Coincidence PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-337881 DO - https://doi.org/10.1016/j.proeng.2015.08.711 SN - 1877-7058 VL - 120 SP - 845 EP - 848 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-33788 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, Franziska A1 - Scholz, G. A1 - Benemann, Sigrid A1 - Rademann, K. A1 - Emmerling, Franziska T1 - Evaluation of the formation pathways of cocrystal polymorphs in liquid-assisted syntheses N2 - The synthesis of the polymorphic cocrystal caffeine:anthranilic acid was investigated to obtain a better understanding of the processes leading to the formation of different polymorphic forms. In the case of these cocrystal polymorphs synthesized by liquid-assisted grinding a distinct influence of the dipole moment of the solvent was found. A pre-coordination between the solvent molecules and the caffeine:anthranilic acid cocrystal could be identified in the formation of form II. In the case of form II the solvent can be regarded as a catalyst. The formation pathway of each polymorph was evaluated using synchrotron X-ray diffraction. KW - cocrystal KW - synchrotron X-ray diffraction KW - caffeine PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-313222 DO - https://doi.org/10.1039/c4ce00472h SN - 1466-8033 VL - 16 IS - 35 SP - 8272 EP - 8278 CY - London, UK AN - OPUS4-31322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ecker, Melanie A1 - Pretsch, Thorsten T1 - Novel design approaches for multifunctional information carriers N2 - Two design approaches for multifunctional information carriers are introduced. In the first one, quick response (QR) code carriers, which were composed of poly(ester urethane) (PEU) and microencapsulated thermochromic pigments (T-PIGs), differing in color and color switching temperature (CST), were prepared. The obtained material systems exhibited machine-readable QR codes at 23 °C and a two-stage decolorization when heated, culminating in unreadable QR codes at temperatures above the highest CST of the employed T-PIGs. In the second scenario, information carriers were sealed with a dark, thermochromic PEU layer. As a result, the QR codes were hidden at 23 °C and became readable upon heating due to color fading. Beyond the characterization of the employed components, preparation methods, functionality analyses and durability investigations are reported. When heated after thermo-mechanical programming, pronounced shape memory properties could be verified. The thermo-responsiveness of such multifunctional material systems may qualify them for usage in anti-counterfeiting applications. KW - Poly(ester urethane) KW - Shape memory polymer KW - Thermo-responsiveness KW - Information carrier KW - QR code carrier KW - Thermochromic properties KW - Microencapsulated thermochromic pigments KW - Anti-counterfeiting KW - Smart label KW - Difficult-to-copy KW - Durability KW - Multifuncitonal material systems PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-315176 DO - https://doi.org/10.1039/c4ra08977d SN - 2046-2069 VL - 4 IS - 87 SP - 46680 EP - 46688 PB - RSC Publishing CY - London AN - OPUS4-31517 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - New X-ray backscatter imaging technique for nondestructive testing of aerospace components N2 - Critical parts in aircraft manufacturing such as stringers are very commonly used in modern aircraft structures to resist the compressive loads caused by the aerodynamic effects. They are generally made-up of thin aluminium (Al) metal sheets and are one of the key components in the aircraft wings. Any defects in the stringer leads to weakening of the stiffness of the whole wing structure and consequently, failures may occur. Hence, the structural integrity of the stringers should be evaluated using reliable non-destructive testing (NDT) methods. Due to the complex shaped structure of the stringer, the one-sided access NDT method such as X-ray backscatter technique is more preferable for the non-destructive imaging. In this paper, we present a new X-ray backscatter technique to image the internal sections of the stringer with only a single-sided access. The whole object was inspected by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (> 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray backscatter imaging KW - Twisted-slit collimator KW - NDT KW - Digital detector array (DDA) KW - Stringer KW - Aerospace applications PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322376 UR - https://www.ndt.net/?id=16431 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-32237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Deresch, Andreas A1 - Redmer, Bernhard A1 - Ewert, Uwe T1 - Dual high-energy X-ray digital radiography for material discrimination in cargo containers N2 - In this contribution, we present a dual high-energy X-ray imaging technique for cargo container inspection using the 'spectral high-energy X-ray attenuation method'. This method is based on attenuation of continuous highenergy spectra. The developed experimental technique consists of a betatron as high-energy (up to 7.5 MeV) X-ray source and a matrix detector with high spatial resolution (400 ìm) for digital X-ray imaging. In order to evaluate the material discrimination capability using dual high-energy X-ray imaging, a test specimen is proposed, comprising step wedges of different low and high atomic number (Z) materials. The selected X-ray spectra for the dual-energy experiments correspond to 3 MV and 7.5 MV acceleration potential of the betatron. We evaluated the ratio between low- and high-energy X-ray attenuation coefficients quantitatively based on simulated poly-energetic high-energy X-ray source spectra and the detector sensitivity using the 'analytical Radiographic Testing inspection simulation tool' (aRTist) developed at BAM. The simulated effective attenuation coefficients are compared with corresponding experimental results in order to establish a method for identification of low- and high-Z materials in the container. Finally, important applications of the proposed technique in the context of aviation security are discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Digital radiography KW - NDT KW - High-energy X-ray imaging KW - Betatron KW - Digital detector array (DDA) KW - Container inspection KW - Material discrimination KW - Effective attenuation coefficient PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322394 UR - https://www.ndt.net/?id=16430 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 10 PB - NDT.net CY - Kirchwald AN - OPUS4-32239 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wrobel, Norma A1 - Kolkoori, Sanjeevareddy A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Innovative X-ray backscatter technique for security applications: Detection of dangerous materials N2 - Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Radiography KW - X-ray backscatter imaging KW - Irradiation geometry KW - Detection of dangerous materials KW - Security applications PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322429 UR - https://www.ndt.net/?id=16432 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-32242 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schick, D. A1 - Herzog, M. A1 - Bojahr, A. A1 - Leitenberger, W. A1 - Hertwig, Andreas A1 - Shayduk, R. A1 - Bargheer, M. T1 - Ultrafast lattice response of photoexcited thin films studied by X-ray diffraction N2 - Using ultrafast X-ray diffraction, we study the coherent picosecond lattice dynamics of photoexcited thin films in the two limiting cases, where the photoinduced stress profile decays on a length scale larger and smaller than the film thickness. We solve a unifying analytical model of the strain propagation for acoustic impedance-matched opaque films on a semi-infinite transparent substrate, showing that the lattice dynamics essentially depend on two parameters: One for the spatial profile and one for the amplitude of the strain. We illustrate the results by comparison with high-quality ultrafast X-ray diffraction data of SrRuO3 films on SrTiO3 substrates. KW - Festkörperphysik KW - Dünnschichttechnik KW - Ellipsometrie KW - Röntgenbeugung KW - Optische Konstanten PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322471 DO - https://doi.org/10.1063/1.4901228 SN - 2329-7778 VL - 1 IS - 6 SP - 064501-1 - 064501-13 PB - AIP Publishing LLC CY - Melville, NY AN - OPUS4-32247 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lexow, Jürgen T1 - Industrial safety - Public demand and an answer of BAM the federal German institute for materials research and testing N2 - Safe industrial operation is expected by the public. It contributes to a clean environment, innovation and prosperity. BAM the Federal German Institute for Materials Research and Testing has its responsibility in further developing safety in technology and chemistry by research, testing and expert advice. The basic reasoning for this activity and examples of current work are provided. Particular attention is given to the unique BAM Test site Technical Safety. Acceptance of fi ndings and transfer of results are based on collaboration and exchange of personal. Modes of cooperation are described. KW - Industrial safety KW - Large test fecility KW - Structural integrity KW - Dangerous substance PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322519 DO - https://doi.org/10.2478/tvsbses-2014-0010 SN - 1805-3238 VL - 9 IS - 2 SP - 40 EP - 45 PB - VSB - Sborník vedeckých prací Vysoké Skoly Bánské - Technické Univerzity Ostrava CY - Ostrava AN - OPUS4-32251 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stegemann, Robert A1 - Sonntag, Nadja A1 - Kreutzbruck, Marc A1 - Skrotzki, Birgit ED - Brune, M. ED - Buffière, J.Y. ED - Morel, F. ED - Nadot, Y. T1 - Self-magnetic-leakage field detection using magneto-optical sensor technique N2 - Measurement of spontaneous magnetic stray field signals has been reported to be a promising tool for capturing macro-scale information of deformation states, defects and stress concentration zones in a material structure. This paper offers a new method for self-magnetic leakage field detection using a magneto-optical (MO) hand-held microscope. Its sensor has a dynamic field range between ±0.05 and ±2 kA/m and a lateral optical resolution of approx. 10 µm. We examined flat tensile test specimens of metastable austenitic steel AISI 304. Static tensile tests were repeatedly interrupted at various predetermined states of strain and the magnetic information was measured by the MO system. Comparative measurements using a high-precision magnetic field GMR-sensor, verify the outstanding capability of the MO microscope regarding spatial resolution of magnetic fields. T2 - FDMDII-JIP 2014 - 14th International spring meeting CY - Paris, France DA - 06.11.2014 KW - Magneto-optical sensor KW - Metal magnetic memory KW - GMR KW - NDT PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-326911 SN - 978-2-7598-1274-5 DO - https://doi.org/10.1051/matecconf/20141204010 N1 - Serientitel: Materials science, Engineering and Chemistry – Series title: Materials science, Engineering and Chemistry VL - 12 SP - 04010-1 EP - 04010-3 PB - EDP Sciences AN - OPUS4-32691 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guo, Y. A1 - Lippitz, Andreas A1 - Saftien, P. A1 - Unger, Wolfgang A1 - Kemnitz, E. T1 - Tuning the surface properties of novel ternary iron(III) fluoride-based catalysts using the template effect of the matrix N2 - Sol–gel prepared ternary FeF3–MgF2 materials have become promising heterogeneous catalysts due to their porosity and surface Lewis/Brønsted acidity (bi-acidity). Despite the good catalytic performance, nanoscopic characterisations of this type of material are still missing and the key factors controlling the surface properties have not yet been identified, impeding both a better understanding and further development of ternary fluoride catalysts. In this study, we characterised the interaction between the bi-acidic component (FeF3) and the matrix (MgF2) on the nano-scale. For the first time, the formation pathway of FeF3–MgF2 was profiled and the template effect of MgF2 during the synthesis process was discovered. Based on these new insights two novel materials, FeF3–CaF2 and FeF3–SrF2, were established, revealing that with decreasing the atomic numbers (from Sr to Mg), the ternary fluorides exhibited increasing surface acidity and surface area but decreasing pore size. These systematic changes gave rise to a panel of catalysts with tuneable surface and bulk properties either by changing the matrix alkaline earth metal fluoride or by adjusting their ratios to Fe or both. The template effect of the alkaline earth metal fluoride matrix was identified as the most probable key factor determining the surface properties and further influencing the catalytic performance in ternary fluoride based catalysts, and paves the way to targeted design of next-generation catalysts with tunable properties. KW - Catalysis KW - Surface analysis KW - XPS PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-327410 DO - https://doi.org/10.1039/c4dt03229b SN - 1477-9226 SN - 1477-9234 SN - 1364-5447 VL - 44 IS - 11 SP - 5076 EP - 5085 PB - RSC CY - Cambridge AN - OPUS4-32741 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Radtke, Martin A1 - Renno, A.D. A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Wedell, R. T1 - Sub-pixel resolution with a color X-ray camera N2 - The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed. KW - Color X-ray camera KW - Sub pixel analysis PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-334948 DO - https://doi.org/10.1039/c5ja00028a SN - 0267-9477 SN - 1364-5544 SP - 1890 EP - 1897 PB - Royal Society of Chemistry CY - London AN - OPUS4-33494 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lukowiak, M.C. A1 - Wettmarshausen, Sascha A1 - Hidde, Gundula A1 - Landsberger, Petra A1 - Boenke, Viola A1 - Rodenacker, K. A1 - Braun, Ulrike A1 - Friedrich, Jörg Florian A1 - Gorbushina, Anna A1 - Haag, R. T1 - Polyglycerol coated polypropylene surfaces for protein and bacteria resistance N2 - Polyglycerol (PG) coated polypropylene (PP) films were synthesized in a two-step approach that involved plasma bromination and subsequently grafting hyperbranched polyglycerols with very few amino functionalities. The influence of different molecular weights and density of reactive linkers were investigated for the grafted PGs. Longer bromination times and higher amounts of linkers on the surface afforded long-term stability. The protein adsorption and bacteria attachment of the PP-PG films were studied. Their extremely low amine content proved to be beneficial for preventing bacteria attachment. PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-325406 DO - https://doi.org/10.1039/c4py01375a SN - 1759-9954 SN - 1759-9962 VL - 6 IS - 8 SP - 1350 EP - 1359 AN - OPUS4-32540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiggenhauser, Herbert A1 - Naus, D.J. T1 - NDE of thick and highly reinforced concrete structures: state of the art N2 - The objective of the report is to present the state-of-the art of non-destructive testing methods and technologies for the inspection of thick, heavily-reinforced structures, (e.g. found in nuclear power plants). Wall thicknesses can be in excess of one meter and the structures often have increased steel reinforcement density. The accessibility for any testing method may be limited due to the presence of liners and other components such as cast-in-place items. Testing methods have to provide solutions for tasks such as locating failure (inclusions, corrosion, voids, delaminations) in the structures or the assessment of the condition of the structure in general. KW - Non-destructuive testing KW - Inspection KW - Nuclear power plant KW - State-of-the-art KW - Highly reinforced concrete KW - NDE KW - Engineering PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-329674 DO - https://doi.org/10.1016/j.proeng.2014.11.055 SN - 1877-7058 VL - 86 SP - 420 EP - 426 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-32967 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Saathoff, F. T1 - Geosynthetics in geoenvironmental engineering N2 - Geosynthetics are planar polymeric products, which are used in connection with soil, rock or other soil-like materials to fulfill various functions in geoenvironmental engineering. Geosynthetics are of ever-growing importance in the construction industry. Sealing of waste storage facilities to safely prevent the emission of wastewater, landfill gas and contaminated dust as well as the diffusion of pollutants into the environment and coastal protection against storms and floods and reconstruction after natural disaster are important fields of application. We will give an overview of the various geosynthetic products. Two examples of the material problems related to geosynthetics are discussed in detail: the effect of creep on the long-term performance of geocomposite drains and the numerical simulation of the interaction of soil with geogrids. Both issues are of importance for the use of these products in landfill capping systems. The various functions, which geosynthetics may fulfill in the protection of coastal lines, are illustrated by case studies. The geosynthetic market is evaluated and economical and environmental benefits, as well as environmental side effects related to the use of geosynthetics, are discussed. KW - Geosynthetics KW - Geoenvironmental engineering KW - Landfill capping system KW - Coastal protection KW - Geocomposite drain KW - Geogrid KW - Geotextile PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-332014 DO - https://doi.org/10.1088/1468-6996/16/3/034605 SN - 1468-6996 VL - 16 IS - 3 SP - 034605-1 EP - 034605-20 PB - Elsevier Science CY - Amsterdam [u.a.] AN - OPUS4-33201 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schütz, Roman A1 - Bertinetti, L. A1 - Rabin, Ira A1 - Fratzl, P. A1 - Masic, A. T1 - Quantifying degradation of collagen in ancient manuscripts: the case of the Dead Sea Temple Scroll N2 - Since their discovery in the late 1940s, the Dead Sea Scrolls, some 900 ancient Jewish texts, have never stopped attracting the attention of scholars and the broad public alike, because they were created towards the end of the Second Temple period and the 'time of Christ'. Most of the work on them has been dedicated to the information contained in the scrolls' text, leaving physical aspects of the writing materials unexamined. They are, however, crucial for both historical insight and preservation of the scrolls. Although scientific analysis requires handling, it is essential to establish the state of degradation of these valued documents. Polarized Raman Spectroscopy (PRS) is a powerful tool for obtaining information on both the composition and the level of disorder of molecular units. In this study, we developed a non-invasive and non-destructive methodology that allows a quantification of the disorder (that can be related to the degradation) of protein molecular units in collagen fibers. Not restricted to collagen, this method can be applied also to other protein-based fibrous materials such as ancient silk, wool or hair. We used PRS to quantify the degradation of the collagen fibers in a number of fragments of the Temple Scroll (11Q19a). We found that collagen fibers degrade heterogeneously, with the ones on the surface more degraded than those in the core. KW - Dead Sea Scrolls KW - Collagen KW - Raman spectroscopy PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-331769 DO - https://doi.org/10.1039/c3an00609c SN - 0003-2654 SN - 1364-5528 VL - 138 IS - 19 SP - 5594 EP - 5599 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-33176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Matzen, Melissa A1 - Kandola, B. A1 - Huth, Christian A1 - Schartel, Bernhard T1 - Influence of flame retardants on the melt dripping behaviour of thermoplastic polymers N2 - Melt flow and dripping of the pyrolysing polymer melt can be both a benefit and a detriment during a fire. In several small-scale fire tests addressing the ignition of a defined specimen with a small ignition source, well-adjusted melt flow and dripping are usually beneficial to pass the test. The presence of flame retardants often changes the melt viscosity crucially. The influence of certain flame retardants on the dripping behaviour of four commercial polymers, poly(butylene terephthalate) (PBT), polypropylene (PP), polypropylene modified with ethylene-propylene rubber (PP-EP) and polyamide 6 (PA 6), is analysed based on an experimental monitoring of the mass loss due to melt dripping, drop size and drop temperature as a function of the furnace temperature applied to a rod-shaped specimen. Investigating the thermal transition (DSC), thermal and thermo-oxidative decomposition, as well as the viscosity of the polymer and collected drops completes the investigation. Different mechanisms of the flame retardants are associated with their influence on the dripping behaviour in the UL 94 test. Reduction in decomposition temperature and changed viscosity play a major role. A flow limit in flame-retarded PBT, enhanced decomposition of flame-retarded PP and PP-EP and the promotion of dripping in PA 6 are the salient features discussed. KW - Fire retardant KW - Viscosity KW - Melt dripping KW - Reaction-to-small-flame KW - UL 94 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-338941 DO - https://doi.org/10.3390/ma8095267 SN - 1996-1944 VL - 8 IS - 9 SP - 5621 EP - 5646 PB - MDPI CY - Basel AN - OPUS4-33894 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schukar, Vivien A1 - Kusche, Nadine A1 - Kalinka, Gerhard A1 - Habel, Wolfgang T1 - Field deployable fiber bragg grating strain patch for long-term stable health monitoring applications N2 - A fiber Bragg grating (FBG) strain patch specially adapted for long-term and high-strain applications has been developed and characterized. The design concept for the patch is based on a glass-fiber reinforced plastic (gfrp) carrier material. The developed concept for the FBG integration into the carrier material was derived from reliable integration procedure of FBG sensors into composite structures. The patches' temperature sensitivity, strain gauge factor, fiber–matrix interface adhesion and fatigue behavior were characterized. As a result, FBG strain patches with linear temperature and strain behavior, as well as excellent fatigue resistance, were developed and can be used as part of a monitoring system for advanced composite materials in aerospace structures or wind turbine power plants. KW - Fiber Bragg grating KW - Patch KW - Strain gauge factor KW - Temperature sensitivity KW - Push-out test KW - Validation KW - Fatigue behavior PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-276271 DO - https://doi.org/10.3390/app3010039 SN - 2076-3417 VL - 3 IS - 1 SP - 39 EP - 54 PB - MDPI CY - Basel AN - OPUS4-27627 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Würth, Christian A1 - Grabolle, Markus A1 - Pauli, Jutta A1 - Spieles, Monika A1 - Resch-Genger, Ute T1 - Relative and absolute determination of fluorescence quantum yields of transparent samples N2 - Luminescence techniques are among the most widely used detection methods in the life and material sciences. At the core of these methods is an ever-increasing variety of fluorescent reporters (i.e., simple dyes, fluorescent labels, probes, sensors and switches) from different fluorophore classes ranging from small organic dyes and metal ion complexes, quantum dots and upconversion nanocrystals to differently sized fluorophore-doped or fluorophore-labeled polymeric particles. A key parameter for fluorophore comparison is the fluorescence quantum yield (Φf), which is the direct measure for the efficiency of the conversion of absorbed light into emitted light. In this protocol, we describe procedures for relative and absolute determinations of Φf values of fluorophores in transparent solution using optical methods, and we address typical sources of uncertainty and fluorophore class-specific challenges. For relative determinations of Φf, the sample is analyzed using a conventional fluorescence spectrometer. For absolute determinations of Φf, a calibrated stand-alone integrating sphere setup is used. To reduce standard-related uncertainties for relative measurements, we introduce a series of eight candidate quantum yield standards for the wavelength region of ~350–950 nm, which we have assessed with commercial and custom-designed instrumentation. With these protocols and standards, uncertainties of 5–10% can be achieved within 2 h. PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-294202 DO - https://doi.org/10.1038/nprot.2013.087 SN - 1754-2189 SN - 1750-2799 VL - 8 IS - 8 SP - 1535 EP - 1550 PB - Nature Publishing Group CY - Basingstoke AN - OPUS4-29420 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilhelm, Stefan A1 - Kaiser, Martin A1 - Würth, Christian A1 - Heiland, J. A1 - Carrillo-Carrion, C. A1 - Muhr, V. A1 - Wolfbeis, Otto S. A1 - Parak, W.J. A1 - Resch-Genger, Ute A1 - Hirsch, T. T1 - Water dispersible upconverting nanoparticles: effects of surface modification on their luminescence and colloidal stability N2 - We present a systematic study on the effect of surface ligands on the luminescence properties and colloidal stability of β-NaYF4:Yb3+,Er3+ upconversion nanoparticles (UCNPs), comparing nine different surface coatings to render these UCNPs water-dispersible and bioconjugatable. A prerequisite for this study was a large-scale synthetic method that yields ~2 g per batch of monodisperse oleate-capped UCNPs providing identical core particles. These ~23 nm sized UCNPs display an upconversion quantum yield of ~0.35% when dispersed in cyclohexane and excited with a power density of 150 W cm-2, underlining their high quality. A comparison of the colloidal stability and luminescence properties of these UCNPs, subsequently surface modified with ligand exchange or encapsulation protocols, revealed that the ratio of the green (545 nm) and red (658 nm) emission bands determined at a constant excitation power density clearly depends on the surface chemistry. Modifications relying on the deposition of additional (amphiphilic) layer coatings, where the initial oleate coating is retained, show reduced non-radiative quenching by water as compared to UCNPs that are rendered water-dispersible via ligand exchange. Moreover, we could demonstrate that the brightness of the upconversion luminescence of the UCNPs is strongly affected by the type of surface modification, i.e., ligand exchange or encapsulation, yet hardly by the chemical nature of the ligand. KW - upconverting nanoparticles (UCNPs) KW - Luminescence KW - surface modification PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324071 DO - https://doi.org/10.1039/c4nr05954a SN - 2040-3364 SN - 2040-3372 VL - 7 IS - 4 SP - 1403 EP - 1410 PB - RSC Publ. CY - Cambridge AN - OPUS4-32407 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mielke, Johannes A1 - Hanke, F. A1 - Peters, M.V. A1 - Hecht, S. A1 - Persson, M. A1 - Grill, L. T1 - Adatoms underneath single porphyrin molecules on Au(111) N2 - The adsorption of porphyrin derivatives on a Au(111) surface was studied by scanning tunneling microscopy and spectroscopy at low temperatures in combination with density functional theory calculations. Different molecular appearances were found and could be assigned to the presence of single gold adatoms bonded by a coordination bond underneath the molecular monolayer, causing a characteristic change of the electronic structure of the molecules. Moreover, this interpretation could be confirmed by manipulation experiments of individual molecules on and off a single gold atom. This study provides a detailed understanding of the role of metal adatoms in surface–molecule bonding and anchoring and of the appearance of single molecules, and it should prove relevant for the imaging of related molecule–metal systems. PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324144 UR - http://pubs.acs.org/doi/pdf/10.1021/ja510528x DO - https://doi.org/10.1021/ja510528x SN - 0002-7863 SN - 1520-5126 VL - 137 IS - 5 SP - 1844 EP - 1849 PB - American Chemical Society CY - Washington, DC AN - OPUS4-32414 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hemmann, Felix A1 - Jäger, Christian A1 - Kemnitz, E. T1 - Comparison of acidic site quantification methods for a series of nanoscopic aluminium hydroxide fluorides N2 - Quantitative determination of acidic surface sites is highly important for the characterization of solid acids because the activity of a catalyst is often related to the concentration of these sites. A recently developed method using 15N Nuclear Magnetic Resonance spectroscopy (NMR) for the quantification of acidic Lewis and Brønsted sites has been tested for a series of nanoscopic aluminum hydroxide fluorides. Comparison with other methods for the quantitative determination of acidic sites shows that this 15N NMR quantification method is a promising technique for the comprehensive investigation of acidic sites. Three different acidic sites, one Brønsted and two Lewis sites, can be distinguished by their 15N chemical shifts of pyridine and simultaneously quantified under conditions corresponding to catalytic reaction conditions. Determination of the individual concentrations of acidic sites allows further insight into the catalytic process. It was found that the concentration of Brønsted sites correlates with catalyzed conversion of citronellal to isopulegol in the investigated series of catalysts. Additionally, investigations indicate that one of the Lewis sites become blocked during the reaction of citronellal. KW - Solid acids KW - TOF KW - NH3-TPD KW - Progressive catalyst poisoning KW - FTIR KW - Quantitative NMR KW - Solid state NMR PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323280 DO - https://doi.org/10.1039/c4ra09477h SN - 2046-2069 VL - 4 IS - 100 SP - 56900 EP - 56909 PB - RSC Publishing CY - London AN - OPUS4-32328 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Bellon, Carsten A1 - Hohendorf, Stefan A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Nusser, A. A1 - Freitag, M. A1 - Bücherl, T. A1 - Bar, D. A1 - Mor, I. A1 - Tamin, N. A1 - Weiss-Babai, R. A1 - Bromberger, B. A1 - Dangendorf, V. A1 - Tittelmeier, K. T1 - Computed tomography with X-rays and fast neutrons for restoration of wooden artwork N2 - The objects of this investigation were sculptures taken from a ca. three hundred years old baroque epitaph of a church in Tonning, a town in Northern Germany. Around 1900 it was found in a disastrous state heavily damaged by wood-worm. At that time, the whole artwork was treated with the tar extract carbolineum as a remedy. Nowadays, this substance has been identified as carcinogenic, and its presence can be perceived by its stench and visually at certain spots on the surface where it has penetrated the covering paint. A gold-painted sculpture of a massive wooden skull was interrogated with X-rays and fast neutrons to investigate the internal distribution of the carbolineum. The X-ray tomography, with its excellent spatial resolution revealed galleries left over from the worm infestation in the outer areas and cracks in the central region. The golden color coating appeared as a thick and dense layer. In comparison the tomography with fast neutrons, though being of lower resolution and yet unresolved artefacts revealed sections of slightly different densities in the bulk of the wood. These differences we attribute to the differences in the distribution of the impregnant in the wood, visible due to its higher hydrogen content making it less transparent for neutrons. T2 - WCNR-10 - 10th World conference on neutron radiography CY - Grindelwald, Switzerland DA - 05.10.2014 KW - Computed tomography KW - Neutron radiology KW - Conservation of wooden artwork PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323050 DO - https://doi.org/10.1016/j.phpro.2015.07.066 SN - 1875-3892 VL - 69 SP - 472 EP - 477 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-32305 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zscherpel, Uwe A1 - Schumacher, David A1 - Redmer, Bernhard A1 - Ewert, Uwe A1 - Ullberg, C. A1 - Weber, N. A1 - Pantsar, T. T1 - Digital radiology with photon counting detectors N2 - The progress in X-ray detector electronics (sensitivity and speed) allows meanwhile fast single photon detection by a matrix detector. Combined photon counting and energy discrimination is implemented in the electronic circuit of each detector pixel. The company XCounter developed detectors based on CdTe single crystals, which can be tiled to larger areas and have a pixel size of 100ìm. The largest area available in beginning of 2014 is 50x75 mm². These detectors have very promising properties, which make them very suitable for NDT applications: 1. A CdTe attenuation layer of 750 µm thickness allows efficient X-ray detection up to ca. 300 keV. In counting mode only photon noise is important; no other detector noise sources need to be considered. There is no Offset signal without radiation. 2. Each of the detector pixels has two energy thresholds. These can be used for dual energy imaging for materials separation. Also the suppression of scattered radiation by energy thresholding will improve the image contrast sensitivity. First experiments will be presented which demonstrate the advantages of this new detector technology over the conventional charge integrating detectors. A challenge is the development of a modified detector calibration procedure, which becomes critical at longer exposure times. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Materials characterization KW - Radiographic testing (RT) KW - Digital detector array KW - Photo counting KW - Image quality KW - Calibration KW - Dual-energy KW - Energy discrimination KW - Digital radiology KW - Detectors PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323063 UR - https://www.ndt.net/?id=16709 SN - 1435-4934 N1 - Geburtsname von Schumacher, David: Walter, D. - Birth name of Schumacher, David: Walter, D. VL - 19 IS - 12 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-32306 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schumm, A. A1 - Martin, E. A1 - Beaumont, M. A1 - Ewert, Uwe A1 - Kolkoori, Sanjeevareddy A1 - Zscherpel, Uwe A1 - Wrobel, Norma A1 - Redmer, Bernhard T1 - A comparative study on the performance of digital detector systems for high energy applications N2 - For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Radiography KW - Image quality KW - Betatron KW - Digital detector array (DDA) KW - Casting KW - Standards KW - High energy radiography KW - Comparison of detectors KW - Steel weldment PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323075 UR - https://www.ndt.net/?id=16394 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 6 PB - NDT.net CY - Kirchwald AN - OPUS4-32307 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe T1 - Minimum requirements for digital radiography equipment and measurement procedures by different industries and standard organizations N2 - The digital photography has almost completely substituted the film photography. The film replacement is also fast progressing in medical X-ray radiography. This process is slower in NDT and especially in Europe. Reasons for the hesitating change to digital radiography (RT-D) in NDT are the necessary time for adoption of standards and the conservative request for film RT by auditors and NDT managers for applications in large plants and at construction areas. The fast serial inspection for small castings is already almost completely dominated by RT-D due to the cost effective short exposure and interpretation times. Standards were developed in parallel at CEN, ISO, ASTM and ASME. Unfortunately, the standard practices are different and the requirements on image quality and useable hardware are different too. The first standard series on Computed Radiography were developed and published by CEN and ASTM in 2005. Harmonized classification and qualification standards are available but the published practices are different. ASTM has developed the first standards for application of Digital Detector Arrays (DDA) in 2010. The first digital RT ISO standard practice is ISO 17636-2 (2013), which describes the practice for application of DDAs and Imaging Plates for weld inspection. At the first time this standard provides requirements for the selection of suitable hardware. Minimum image quality requirements are specified in analogy to film radiography and 3 Compensation Principles are defined to enable the application of a wider range of digital detectors. A comparison of the different international digital RT standards is given and first experiences with ISO 17636-2 are discussed. New standards on RT wall thickness and corrosion measurements (EN 16407, film and digital) have been developed recently. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - NDT KW - X-Ray KW - Digital detectors KW - Standards KW - Radiographic procedures KW - Unsharpness KW - Basic spatial resolution KW - Requirements KW - Digital industrial radiology PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323081 UR - https://www.ndt.net/?id=16708 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 18 PB - NDT.net CY - Kirchwald AN - OPUS4-32308 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppe, Enrico A1 - Augustin, D. A1 - Bartholmai, Matthias A1 - Daum, Werner T1 - Air-based multi-hop sensor network for the localization of persons N2 - In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions. T2 - EuroSensors 2014, 28th European Conference on Solid-State Transducers CY - Brescia, Italy DA - 07.09.2014 KW - WSN KW - Mesh routing KW - Air-based KW - Multi-hop KW - Localization PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324294 DO - https://doi.org/10.1016/j.proeng.2014.11.540 SN - 1877-7058 VL - 87 SP - 528 EP - 531 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-32429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Curado, Jessica A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. T1 - Slicing - a new method for non destructive 3D elemental sensitive characterization of materials N2 - Recent advances in synchrotron sources and detector technology have led to substantial improvements in spatial resolution and detection limits for X-ray fluorescence analysis (XRF). However, the non-destructive three-dimensional elemental sensitive characterization of samples remains a challenge. We demonstrate the use of the so-called 'Color X-ray Camera' (CXC) for 3D measurements for the first time. The excitation of the sample is realized with a thin sheet-beam. The stepwise movement of the sample allows getting the elemental distribution for each layer with one measurement. These layers can be combined to a full 3D dataset for each element afterwards. Since the information is collected layer by layer, there is no need to apply reconstruction techniques, which quite often are the reason for artifacts in the results achieved by computed tomography (CT). The field of applications is wide, as the 3D elemental distribution of a material contains clues to processes inside the samples from a variety of origins. The technique is of special interest and well suited for biological specimens, because their light matrix minimizes restricting absorption effects. Measurement examples of a hornet and the teeth of a Sorex araneus are shown. KW - SR-microXRF KW - 3D KW - CXC PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324330 DO - https://doi.org/10.1039/c4ja00085d SN - 0267-9477 SN - 1364-5544 VL - 29 IS - 8 SP - 1339 EP - 1344 PB - Royal Society of Chemistry CY - London AN - OPUS4-32433 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, Franziska A1 - Scholz, G. A1 - Batzdorf, Lisa A1 - Wilke, Manuel A1 - Emmerling, Franziska T1 - Synthesis, structure determination, and formation of a theobromine: oxalic acid 2:1 cocrystal N2 - The structure and the formation pathway of a new theobromine : oxalic acid (2 : 1) cocrystal are presented. The cocrystal was synthesised mechanochemically and its structure was solved based on the powder X-ray data. The mechanochemical synthesis of this model compound was studied in situ using synchrotron XRD. Based on the XRD data details of the formation mechanism were obtained. The formation can be described as a self-accelerated ('liquid like') process from a highly activated species. KW - ssNMR spectroscopy KW - Synchrotron measurements KW - API molecule PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-331567 DO - https://doi.org/10.1039/c4ce02066a SN - 1466-8033 VL - 17 IS - 4 SP - 824 EP - 829 CY - London, UK AN - OPUS4-33156 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kramer, Claus A1 - Ried, Peter A1 - Mahn, Stefan A1 - Richter, Silke A1 - Langhammer, Nicole A1 - Kipphardt, Heinrich T1 - Design and application of a versatile gas calibration for non-metal determination by carrier gas hot extraction N2 - In carrier gas hot extraction the calibration of low amounts of non-metals with masses of a few micrograms with small uncertainty remains a challenge. To achieve high flexibility a high precision gas mixture pump was combined with an automated syringe drive. The gas mixing pump allows filling the syringe with different gas compositions; the automated syringe drive allows matching to modulate the signal profiles to those of real samples. The system was designed and its experimental potential explored. The resulting calibration curves were comparable to those obtained by calibration using solid materials of sufficient purity and stoichiometry. However smaller uncertainties and lower limits of quantification (i.e. 0.5 µg and 0.6 µg for O and N, respectively) were found using the gas calibration device. KW - Non-metal determination KW - CGHE KW - Gas calibration PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-336130 DO - https://doi.org/10.1039/c5ay00845j SN - 1759-9660 SN - 1759-9679 VL - 7 IS - 13 SP - 5468 EP - 5475 PB - RSC Publ. CY - Cambridge AN - OPUS4-33613 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A1 - Bierkandt, Frank A1 - Rades, Steffi A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Sample loss in asymmetric flow field-flow fractionation coupled to inductively coupled plasma-mass spectrometry of silver nanoparticles N2 - In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study. KW - Asymmetric flow filed-flow fractionation KW - ICP-MS KW - Nanoparticles KW - Sample loss KW - Quantification PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-336171 DO - https://doi.org/10.1039/c5ja00297d SN - 0267-9477 SN - 1364-5544 VL - 30 IS - 10 SP - 2214 EP - 2222 PB - Royal Society of Chemistry CY - London AN - OPUS4-33617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hansen, Ulf A1 - Thünemann, Andreas T1 - Characterization of silver nanoparticles in cell culture medium containing fetal bovine serum N2 - Nanoparticles are being increasingly used in consumer products worldwide, and their toxicological effects are currently being intensely debated. In vitro tests play a significant role in nanoparticle risk assessment, but reliable particle characterization in the cell culture medium with added fetal bovine serum (CCM) used in these tests is not available. As a step toward filling this gap, we report on silver ion release by silver nanoparticles and on changes in the particle radii and in their protein corona when incubated in CCM. Particles of a certified reference material, p1, and particles of a commercial silver nanoparticle material, p2, were investigated. The colloidal stability of p1 is provided by the surfactants polyethylene glycol-25 glyceryl trioleate and polyethylene glycol-20 sorbitan monolaurate, whereas p2 is stabilized by polyvinylpyrrolidone. Dialyses of p1 and p2 reveal that their silver ion release rates in CCM are much larger than in water. Particle characterization was performed with asymmetrical flow field-flow fractionation, small-angle X-ray scattering, dynamic light scattering, and electron microscopy. p1 and p2 have similar hydrodynamic radii of 15 and 16 nm, respectively. The silver core radii are 9.2 and 10.2 nm. Gel electrophoresis and subsequent peptide identification reveal that albumin is the main corona component of p1 and p2 after incubation in CCM that consists of Dulbecco's modified Eagle medium with 10% fetal bovine serum added. PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-335510 DO - https://doi.org/10.1021/acs.langmuir.5b00687 SN - 0743-7463 SN - 1520-5827 VL - 31 IS - 24 SP - 6842 EP - 6852 PB - American Chemical Society CY - Washington, DC AN - OPUS4-33551 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Andrae, K. A1 - Merkel, Stefan A1 - Durmaz, V. A1 - Fackeldey, K. A1 - Köppen, Robert A1 - Weber, M. A1 - Koch, Matthias T1 - Investigation of the ergopeptide epimerization process N2 - Ergopeptides, like ergocornine and a-ergocryptine, exist in an S- and in an R-configuration. Kinetic experiments imply that certain configurations are preferred depending on the solvent. The experimental methods are explained in this article. Furthermore, computational methods are used to understand this configurational preference. Standard quantum chemical methods can predict the favored configurations by using minimum energy calculations on the potential energy landscape. However, the explicit role of the solvent is not revealed by this type of methods. In order to better understand its influence, classical mechanical molecular simulations are applied. It appears from our research that 'folding' the ergopeptide molecules into an intermediate state (between the S- and the R-configuration) is mechanically hindered for the preferred configurations. KW - Ergopeptide KW - Epimerization KW - Hybrid monte carlo KW - Molecular dynamics KW - Conformation KW - Quantum mechanics PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324632 DO - https://doi.org/10.3390/computation2030102 SN - 2079-3197 VL - 2 IS - 3 SP - 102 EP - 111 PB - MDPI CY - Basel AN - OPUS4-32463 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cordeiro, F. A1 - Llorente-Mirandes, T. A1 - López-Sánchez, J.F. A1 - Rubio, R. A1 - Sánchez-Agullo, A. A1 - Raber, G. A1 - Scharf, Holger A1 - Vélez, D. A1 - Devesa, V. A1 - Fiamegos, Y. A1 - Emteborg, H. A1 - Seghers, J. A1 - Robouch, P. A1 - De la Calle, M.B. T1 - Determination of total cadmium, lead, arsenic, mercury and inorganic arsenic in mushrooms: outcome of IMEP-116 and IMEP-39 N2 - The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39. KW - Inorganic arsenic KW - Trace elements KW - Mushrooms KW - Proficiency test PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-326092 DO - https://doi.org/10.1080/19440049.2014.966336 SN - 1944-0057 SN - 1944-0049 VL - 32 IS - 1 SP - 54 EP - 67 PB - Taylor & Francis CY - London [u.a.] AN - OPUS4-32609 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kotschate, Daniel A1 - Gohlke, Dirk A1 - Heckel, Thomas T1 - Three dimensional examination of directivity pattern in immersion tank testing N2 - High resolution examination of safety-relevant parts in immersion tank testing with focussing probes is forming a main topic of modern non-destructive testing. For the usage of complex reconstruction methods and algorithms, an individual and detailed knowledge about the transmission behaviour of the used probes is essential, as this has a significant influence on the results of data reconstruction. Especially the knowledge about position and diameter of the focal point is needed to achieve the highest possible sensitivity. Through the individual position of the beam axis within the examined volume, a four dimensional metro logical determination of the acoustical pressure (x, y, z, t) is necessary. With the measured data it is possible to draw interferences about the sound field and acoustical pressure distribution. The presented work realized a method of automatic determination of the beam axis, the position of focal point and the focal diameter to support individual testing setups and transducer characterization. T2 - 7th International Symposium on NDT in Aerospace CY - Bremen, Germany DA - 16.11.2015 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-339995 AN - OPUS4-33999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Manke, I. A1 - Kardjilov, N. A1 - Schäfer, R. A1 - Hilger, A. A1 - Grothausmann, R. A1 - Strobl, M. A1 - Dawson, M. A1 - Grünzweig, C. A1 - Tötzke, C. A1 - David, C. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Banhart, J. T1 - Three-dimensional imaging of magnetic domains with neutron grating interferometry N2 - This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique. KW - Neutron imaging KW - Tomography KW - Magnetic domains KW - Grating interferometry KW - Darkfield imaging KW - Shearing gratings KW - Talbot-Lau KW - Three-dimensional data quantification KW - Tomographic reconstruction PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-341919 DO - https://doi.org/10.1016/j.phpro.2015.07.057 SN - 1875-3892 VL - 69 SP - 404 EP - 412 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-34191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -