TY - JOUR A1 - Kalbe, Ute A1 - Piechotta, Christian A1 - Bandow, Nicole T1 - Comparing PFAS analysis in batch leaching and column leaching tests N2 - Laboratory leaching tests are tools to assess the mobility of environmental contaminants released from granular materials. Comparative leaching tests were performed using four PFAS-contaminated soils whose concentration patterns of 10 selected perfluoroalkyl and polyfluoroalkyl substances (PFAS) differed due to the two types of contamination sources. This study aimed to evaluate the equivalence of two usual laboratory-scale leaching test procedures, batch and column percolation tests, at liquid-to-solid ratios (L/S) of 2 l/kg, which is the current practice within the German assessment framework, and 10 l/kg (relevant for some EU regulations such as the landfill directive). The differences between the replicates of leaching tests investigating PFAS were smaller for column percolation tests than for batch tests, probably mainly due to the greater sample size and the better representativeness of the sample portion analyzed. It was observed that batch tests overestimate the release of shorter-chain PFAS, whereby the effect was greater with carboxylic than with sulfonic acids. Currently, the limits of detection of analyses given by the DIN standard with regard to PFCA and PFSA in soils are partly not sufficient to detect very low contents, whereas the detection of selected PFCA and PFSA in eluates is more sensitive, in accordance with the available standards. This results in limitations when calculating mass balances. KW - PFAS KW - Leaching KW - Column percolation test KW - Batch test KW - Soil PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-618187 DO - https://doi.org/10.1007/s11356-024-35510-0 SN - 1614-7499 VL - 31 IS - 57 SP - 65233 EP - 65251 PB - Springer Science and Business Media LLC AN - OPUS4-61818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rosen, Andrew S. A1 - Gallant, Max A1 - George, Janine A1 - Riebesell, Janosh A1 - Sahasrabuddhe, Hrushikesh A1 - Shen, Jimmy-Xuan A1 - Wen, Mingjian A1 - Evans, Matthew L. A1 - Petretto, Guido A1 - Waroquiers, David A1 - Rignanese, Gian-Marco A1 - Persson, Kristin A. A1 - Jain, Anubhav A1 - Ganose, Alex M. T1 - Jobflow: Computational Workflows Made Simple N2 - We present Jobflow, a domain-agnostic Python package for writing computational workflows tailored for high-throughput computing applications. With its simple decorator-based approach, functions and class methods can be transformed into compute jobs that can be stitched together into complex workflows. Jobflow fully supports dynamic workflows where the full acyclic graph of compute jobs is not known until runtime, such as compute jobs that launch other jobs based on the results of previous steps in the workflow. The results of all Jobflow compute jobs can be easily stored in a variety of filesystem- and cloud-based databases without the data storage process being part of the underlying workflow logic itself. Jobflow has been intentionally designed to be fully independent of the choice of workflow manager used to dispatch the calculations on remote computing resources. At the time of writing, Jobflow workflows can be executed either locally or across distributed compute environments via an adapter to the FireWorks package, and Jobflow fully supports the integration of additional workflow execution adapters in the future. KW - Automation KW - Workflow KW - Computational Materials Science KW - Computations KW - Software PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-593104 DO - https://doi.org/10.21105/joss.05995 VL - 9 IS - 93 SP - 1 EP - 7 PB - The Open Journal AN - OPUS4-59310 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ghosh, Sheuly A1 - Ueltzen, Katharina A1 - George, Janine A1 - Neugebauer, Jörg A1 - Körmann, Fritz T1 - Chemical ordering and magnetism in face-centered cubic CrCoNi alloy N2 - AbstractThe impact of magnetism on chemical ordering in face-centered cubic CrCoNi medium entropy alloy is studied by a combination of ab initio simulations, machine learning potentials, and Monte Carlo simulations. Large magnetic energies are revealed for some mixed L12/L10 type ordered configurations, which are rooted in strong nearest-neighbor magnetic exchange interactions and chemical bonding among the constituent elements. There is a delicate interplay between magnetism and stability of MoPt2 and L12/L10 type of order, which may explain opposing experimental and theoretical findings. KW - Chemically complex materials KW - Alloys KW - Magnetism KW - Bonding analysis KW - Machine learning KW - Machine-learned interatomic potentials PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-623114 DO - https://doi.org/10.1038/s41524-024-01439-8 SN - 2057-3960 VL - 10 IS - 1 SP - 1 EP - 10 PB - Springer Science and Business Media LLC AN - OPUS4-62311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nicolicea, Alberto A1 - Oliveros-Mata, E. S. A1 - Zabila, Y. A1 - Makarov, D. A1 - Melzer, Michael A1 - Pelkner, Matthias T1 - Flexible anisotropic magnetoresistive sensors for novel magnetic flux leakage testing capabilities N2 - Rigid magnetic field sensors such as anisot Hall sensors have been used for years and have become industry standard for electromagnetic non-destructive testing (NDT). Recent technological developments in the field of flexible electronics allow for the fabrication of reshapeable magnetic field sensors on flexible substrates via thin-film deposition or printing. The magnetic properties of these sensors have comparable characteristics to industry-standard rigid magnetic field sensors, with the added ability of adapting to the surface of complex components and scanning in contact with the sample surface. This improves defect detectability and magnetic signal strength by minimizing the scanning lift-off (LO) distance. In this article flexible AMR sensors mounted on a rotative mechanical holder were used to scan a semi-circular ferromagnetic sample with 3 reference defects via magnetic flux leakage (MFL) testing, thus demonstrating the applicability of this type of sensors for the scanning of curved samples. In order to benchmark the performance of these sensors in comparison to industry standard rigid magnetic field sensors, a ferromagnetic sample with 10 reference defects of different depths was scanned employing flexible AMR and rigid GMR sensors. Defects with depths ranging from 110 μm up to 2240 μm were detected with an signal-tonoise ratio (SNR) of 2.7 up to 27.9 (for flexible AMR sensors) and 6.2 up to 72.3 (for rigid GMR sensors), respectively. A 2D magnetometer mapping of the sample with a spatial scanning step of 10 × 50 μm2 (flexible AMR) and 16 × 100 μm2 (rigid GMR) was obtained. The results show that this type of sensor can be used for high-resolution and high-detail mapping of defects on the surface of planar and non-planar ferromagnetic samples since the scanning lift-off distance is equal to the substrate thickness of 20 μm for in-contact scanning. The SNR comparison between flexible and rigid sensors shows that the performance of the flexible AMR sensors employed is not very far behind the performance of the rigid GMR sensors used. KW - Flexible magnetic field sensors KW - Non-destructive testing KW - Magnetic flux leakage KW - Thin film sensor fabrication KW - Defect detection PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-603931 DO - https://doi.org/10.1016/j.ndteint.2024.103160 SN - 0963-8695 VL - 146 SP - 1 EP - 15 PB - Elsevier CY - Amsterdam AN - OPUS4-60393 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidinger, J. A1 - Barkov, V. A1 - Tavakoli, H. A1 - Correa, J. A1 - Ostermann, Markus A1 - Atzmueller, M. A1 - Gebbers, R. A1 - Vogel, S. T1 - Which and how many soil sensors are ideal to predict key soil properties: A case study with seven sensors N2 - Soil sensing enables rapid and cost-effective soil analysis. However, a single sensor often does not generate enough information to reliably predict a wide range of soil properties. Within a case-study, our objective was to identify how many and which combinations of soil sensors prove to be suitable for high-resolution soil mapping. On a subplot of an agricultural field showing a high spatial soil variability, six in-situ proximal soil sensors (PSSs) next to remote sensing (RS) data from Sentinel-2 were evaluated based on their capabilities to predict a set of soil properties including: soil organic carbon, pH, moisture as well as plant-available phosphorus, magnesium and potassium. The set of PSSs consisted of ion-selective pH electrodes, a capacitive soil moisture sensor, an apparent soil electrical conductivity measuring system as well as passive gamma-ray-, X-ray fluorescence- and nearinfrared spectroscopy. All possible combinations of sensors were exhaustively evaluated and ranked based on their predict KW - XRF KW - Soil KW - Remote Sensing KW - Precision agriculture PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613920 DO - https://doi.org/10.1016/j.geoderma.2024.117017 VL - 450 SP - 1 EP - 17 PB - Elsevier B.V. AN - OPUS4-61392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Andrea A1 - Liestmann, Zoe A1 - Zaenker, Steffen A1 - Vogel, Kristin A1 - Broszies, Tanja A1 - Ostermann, Markus T1 - How reliable is the X‐ray fluorescence‐based differentiation between glass wool and rock wool and the age classification of rock wool? N2 - AbstractA prerequisite for the recycling of mineral wool is information about the type of material, that is, whether it is glass wool or rock wool. As mineral wool produced before the year 2000 can be potentially carcinogenic, it is furthermore important to distinguish between “old” and “new” wool when handling the material. Based on VDI 3492, it is possible to determine the material and, in the case of rock wool, the age by analyzing the mass fractions of eight oxides, which are the main components of mineral wool. This study presents the X‐ray fluorescence (XRF) analyses of 141 man‐made mineral fibers collected in Germany. Only in a few cases it was not possible to clearly assign the material type. In contrast, the identification of “old” and “new” rock wool posed a challenge as there were many borderline samples. Based on the available data, a chemometric model was developed that can classify “old” and “new” RW with a sensitivity of 93% and 89% and with a specificity of 100% in both cases. However, care must be taken when oxide contents are close to the specification limits. The reason for this mainly lies in the overlapping intervals of key oxides as suggested by VDI 3492, and, to a lesser extent, in the uncertainties typically occurring in the XRF‐based analysis of oxides. With this study, a comprehensive collection and evaluation of XRF data on mineral wool is made available, which can serve as a reference database for future users. KW - Mineral wool KW - RFA KW - Multivariate data analysis KW - VDI 3492 PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-610285 DO - https://doi.org/10.1002/xrs.3451 SN - 1097-4539 SP - 1 EP - 11 PB - Wiley CY - New York, NY AN - OPUS4-61028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thiele, Isabel A1 - Santolin, Lara A1 - Meyer, Klas A1 - Machatschek, Rainhard A1 - Bölz, Uwe A1 - Tarazona, Natalia A. A1 - Riedel, Sebastian L. T1 - Microbially synthesized poly(hydroxybutyrate-co-hydroxyhexanoate) with low to moderate hydroxyhexanoate content: Properties and applications N2 - Plastic pollution is the biggest environmental concern of our time. Breakdown products like micro- and nanoplastics inevitably enter the food chain and pose unprecedented health risks. In this scenario, bio-based and biodegradable plastic alternatives have been given a momentum aiming to bridge a transition towards a more sustainable future. Polyhydroxyalkanoates (PHAs) are one of the few thermoplastic polymers synthesized 100 % via biotechnological routes which fully biodegrade in common natural environments. Poly(hydroxybutyrate-cohydroxyhexanoate) [P(HB-co-HHx)] is a PHA copolymer with great potential for the commodity polymers industry, as its mechanical properties can be tailored through fine-tuning of its molar HHx content. We have recently developed a strategy that enables for reliable tailoring of the monomer content of P(HB-co-HHx). Nevertheless, there is often a lack of comprehensive investigation of the material properties of PHAs to evaluate whether they actually mimic the functionalities of conventional plastics. We present a detailed study of P(HB-co-HHx) copolymers with low to moderate hydroxyhexanoate content to understand how the HHx monomer content influences the thermal and mechanical properties and to link those to their abiotic degradation. By increasing the HHx fractions in the range of 2 – 14 mol%, we impart an extension of the processing window and application range as the melting temperature (Tm) and glass temperature (Tg) of the copolymers decrease from Tm 165 ◦C to 126 ◦C, Tg 4 ◦C to − 5.9 ◦C, accompanied by reduced crystallinity from 54 % to 20 %. Elongation at break was increased from 5.7 % up to 703 % at 14 mol% HHx content, confirming that the range examined was sufficiently large to obtain ductile and brittle copolymers, while tensile strength was maintained throughout the studied range. Finally, accelerated abiotic degradation was shown to be slowed down with an increasing HHx fraction decreasing from 70 % to 55 % in 12 h. KW - Molecular Biology KW - General Medicine KW - Biochemistry KW - Structural Biology PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-595636 DO - https://doi.org/10.1016/j.ijbiomac.2024.130188 VL - 263 SP - 1 EP - 9 PB - Elsevier B.V. AN - OPUS4-59563 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Villajos Collado, José Antonio A1 - Balderas‐Xicohténcatl, Rafael A1 - Al Shakhs, Ali N. A1 - Berenguer‐Murcia, Ángel A1 - Buckley, Craig E. A1 - Cazorla‐Amorós, Diego A1 - Charalambopoulou, Georgia A1 - Couturas, Fabrice A1 - Cuevas, Fermin A1 - Fairen‐Jimenez, David A1 - Heinselman, Karen N. A1 - Humphries, Terry D. A1 - Kaskel, Stefan A1 - Kim, Hyunlim A1 - Marco‐Lozar, Juan P. A1 - Oh, Hyunchul A1 - Parilla, Philip A. A1 - Paskevicius, Mark A1 - Senkovska, Irena A1 - Shulda, Sarah A1 - Silvestre‐Albero, Joaquin A1 - Steriotis, Theodore A1 - Tampaxis, Christos A1 - Hirscher, Michael A1 - Maiwald, Michael T1 - Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study N2 - AbstractHydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material. KW - Physical and theoretical chemistry KW - Atomic and molecular physics, and optics PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-594788 DO - https://doi.org/10.1002/cphc.202300794 SN - 1439-7641 SP - 1 EP - 7 PB - Wiley CY - Weinheim AN - OPUS4-59478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhuang, Y. A1 - Spahr, S. A1 - Lutze, H.V. A1 - Reith, C.J. A1 - Hagemann, N. A1 - Paul, Andrea A1 - Haderlein, S.B. T1 - Persulfate activation by biochar and iron: Effect of chloride on formation of reactive species and transformation of N,N-diethyl-m-toluamide (DEET) N2 - Fenton-like processes using persulfate for oxidative water treatment and contaminant removal can be enhanced by the addition of redox-active biochar, which accelerates the reduction of Fe(III) to Fe(II) and increases the yield of reactive species that react with organic contaminants. However, available data on the formation of non-radical or radical species in the biochar/Fe(III)/persulfate system are inconsistent, which limits the evaluation of treatment efficiency and applicability in different water matrices. Based on competition kinetics calculations, we employed different scavengers and probe compounds to systematically evaluate the effect of chloride in presence of organic matter on the formation of major reactive species in the biochar/Fe(III)/persulfate system for the transformation of the model compound N,N‑diethyl-m-toluamide (DEET) at pH 2.5. We show that the transformation of methyl phenyl sulfoxide (PMSO) to methyl phenyl sulfone (PMSO2) cannot serve as a reliable indicator for Fe(IV), as previously suggested, because sulfate radicals also induce PMSO2 formation. Although the formation of Fe(IV) cannot be completely excluded, sulfate radicals were identified as the major reactive species in the biochar/Fe(III)/persulfate system in pure water. In the presence of dissolved organic matter, low chloride concentrations (0.1 mM) shifted the major reactive species likely to hydroxyl radicals. Higher chloride concentrations (1 mM), as present in a mining-impacted acidic surface water, resulted in the formation of another reactive species, possibly Cl2•−, and efficient DEET degradation. To tailor the application of this oxidation process, the water matrix must be considered as a decisive factor for reactive species formation and contaminant removal. KW - Water treatment KW - Organic contaminants KW - Fenton-like systems KW - Radicals KW - ESR PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-608677 DO - https://doi.org/10.1016/j.watres.2024.122267 SN - 0043-1354 VL - 265 SP - 1 EP - 8 PB - Elsevier Ltd. AN - OPUS4-60867 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Zengchao A1 - Winckelmann, Alexander A1 - Vogl, Jochen A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Determination of calcium, iron, and selenium in human serum by isotope dilution analysis using nitrogen microwave inductively coupled atmospheric pressure plasma mass spectrometry (MICAP-MS) N2 - In this study, we demonstrate the applicability of nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) for Ca, Fe, and Se quantification in human serum using isotope dilution (ID) analysis. The matrix tolerance of MICAP-MS in Na matrix was investigated, uncovering that high Na levels can suppress the signal intensity. This suppression is likely due to the plasma loading and the space charge effect. Moreover, 40Ca and 44Ca isotopic fractionation was noted at elevated Na concentration. Nine certified serum samples were analyzed using both external calibration and ID analysis. Overestimation of Cr, Zn, As, and Se was found in the results of external calibration, which might be resulted from C-induced polyatomic interference and signal enhancement, respectively. Further investigations performed with methanol showed a similar enhancement effect for Zn, As, and Se, potentially supporting this assumption. The mass concentrations determined with ID analysis show metrological compatibility with the reference values, indicating that MICAP-MS combined with ID analysis can be a promising method for precise Ca, Fe, and Se determination. Moreover, this combination reduces the influences of matrix effects, broadening the applicability of MICAP-MS for samples with complex matrix. KW - Selenium KW - Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry KW - Isotope dilution KW - Human serum KW - Calcium KW - Iron PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-598664 DO - https://doi.org/10.1007/s00216-024-05274-0 SN - 1618-2642 SP - 3117 EP - 3125 PB - Springer CY - Berlin AN - OPUS4-59866 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -