TY - JOUR A1 - Herter, Sven-Oliver A1 - Haase, Hajo A1 - Koch, Matthias T1 - Semisynthesis of Stable Isotope-Labeled Ergot Alkaloids for HPLC-MS/MS Analysis N2 - Ergot alkaloids (EAs) are prevalent food contaminants affecting cereals, such as rye, wheat, and barley worldwide. To ensure EU safety standards, the six most common EAs: ergometrine, ergotamine, ergosine, ergocornine, ergocristine, and ergocryptine, and their epimers, are quantified using HPLC-MS/MS, as described in the European Standard Method EN 17425:2021. However, this can be challenging and time-consuming in food matrices without appropriate internal standards and highlights the need for more robust and precise analytical tools to support their monitoring. The development of isotope-labeled EAs directly addresses this gap, offering improved accuracy and leading to more consistency across laboratories and consequently to more consumer safety. Therefore, we developed a semisynthetic approach, building upon our previous work where native ergotamine was N6-demethylated to norergotamine and subsequently remethylated using iodomethane (13CD3-I). Herein, we are now able to present the successful synthesis of all of the isotopically labeled priority EAs. These isotope-labeled standards were tested against their native counterparts using HPLC coupled with HR-MS/MS. The chromatographic and mass spectrometric properties of the unlabeled and isotopically labeled EAs match exactly, confirming their successful synthesis and structure. These standards can now be utilized to enhance the accuracy and reliability of EA quantification in food and feed. KW - Reference Material KW - HPLC-MS/MS KW - Mycotoxins KW - Ergot Alkaloids KW - Stable Isotope Dilution Analysis KW - Semisynthesis PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639692 DO - https://doi.org/10.1021/acs.jafc.5c03345 SN - 0021-8561 VL - 73 IS - 29 SP - 18412 EP - 18419 PB - American Chemical Society (ACS) AN - OPUS4-63969 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stiegler, L. M. S. A1 - Wegner, Karl David A1 - Weigert, Florian A1 - Peukert, W. A1 - Resch-Genger, Ute A1 - Walter, J. T1 - Analysis of Giant-Shell CdSe/CdS Quantum Dots via Analytical Ultracentrifugation Combined with Spectrally Resolved Photoluminescence N2 - Knowledge of the structure–property relationships of functional nanomaterials, including, for example, their size- and composition-dependent photoluminescence (PL) and particle-to-particle variations, is crucial for their design and reproducibility. Herein, the Angstrom-resolution capability of an analytical ultracentrifuge combined with an in-line multiwavelength emission detection system (MWE-AUC) for measuring the sedimentation coefficient-resolved spectrally corrected PL spectra of dispersed nanoparticles is demonstrated. The capabilities of this technique are shown for giant-shell CdSe/CdS quantum dots (g-QDs) with a PL quantum yield (PL QY) close to unity capped with oleic acid and oleylamine ligands. The MWE-AUC PL measurements are calibrated and validated with certified fluorescence standards. The spectrally corrected and size-dependent PL spectra of the g-QDs derived from a single MWE-AUC experiment are then analyzed and compared with the results of single-particle spectroscopic studies, yielding the PL spectra, decay kinetics, and blinking behavior of individual g-QDs. This study underlines the vast potential of MWE-AUC with in-line optical detection for the characterization of advanced nanomaterials with a complex structure. KW - Quantum dots KW - Analytical ultracentrifugation KW - Photoluminescence KW - Advanced nanomaterial characterization KW - Calibrated fluorescence measurements KW - Reference materials PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-624357 DO - https://doi.org/10.1002/smtd.202401700 SN - 2366-9608 SP - 1 EP - 7 PB - Wiley VHC-Verlag AN - OPUS4-62435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Maria A1 - Güttler, Arne A1 - Pauli, Jutta A1 - Vogel, K. A1 - Homann, Christian A1 - Würth, Christian A1 - Resch-Genger, Ute T1 - Extending certified spectral fluorescence standards for the calibration and performance validation of fluorescence instruments to the NIR—closing the gap from 750 to 940 nm with two novel NIR dyes N2 - Fluorescence techniques such as fluorescence spectroscopy, microfluorometry, and fluorescence microscopy, providing spectral, intensity, polarization, and lifetime information, are amongst the most broadly utilized analytical methods in the life and materials sciences. However, the measured fluorescence data contain sample- and instrument-specific contributions, which hamper their comparability across instruments and laboratories. Comparable, instrument-independent fluorescence data require the determination of the fluorescence instrument’s wavelength-dependent spectral responsivity, also termed emission correction curve, for the same instrument settings as those used for the fluorescence measurements as a prerequisite for the subsequent correction of the measured instrument-specific data. Such a spectral correction is essential for the performance comparison of different fluorescent labels and reporters, quantitative fluorescence measurements, the determination of the fluorescence quantum yield, and the spectroscopic measure for the fluorescence efficiency of a fluorophore. Simple-to-use tools for obtaining emission correction curves are chromophore-based reference materials (RMs), referred to as fluorescence standards, with precisely known, preferably certified instrument-independent fluorescence spectra. However, for the increasingly used near-infrared (NIR) wavelength region >700 nm, at present, no spectral fluorescence standards are available. To close this gap, we developed two novel spectral fluorescence standards, BAM F007 and BAM-F009, with broad emission bands from about 580 to 940 nm in ethanolic solution. These liquid fluorescence standards currently under certification, which will be released in 2025, will expand the wavelength range of the already available certified Calibration Kit BAM F001b-F005b from about 300–730 to 940 nm. In this research article, we will detail the criteria utilized for dye and matrix selection and the homogeneity and stability tests accompanying dye certification as well as the calculation of the wavelength-dependent uncertainty budgets of the emission spectra BAM F007 and BAM-F009, determined with the traceably calibrated BAM reference spectrofluorometer. These fluorescence standards can provide the basis for comparable fluorescence measurements in the ultraviolet, visible, and NIR for the fluorescence community. KW - Quality assurance KW - Reference material KW - Fluorescence KW - Dye KW - Traceability KW - Metrology KW - Calibration KW - Reference data KW - Reference product KW - Digital certificate KW - NIR KW - Instrument performance validation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-626317 DO - https://doi.org/10.1007/s00216-024-05723-w SN - 1618-2650 SP - 1 EP - 15 PB - Springer AN - OPUS4-62631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krappe, Alexander R. A1 - Mayer, Jacob C. A1 - Zhang, Wuai A1 - Filla, Lina M. A1 - Ligorio, Giovanni A1 - Hermerschmidt, Felix A1 - Eitelhuber, Larissa S. A1 - Güttler, Arne A1 - Weber, Manuela A1 - Paulus, Beate A1 - Resch-Genger, Ute A1 - List-Kratochvil, Emil J.W. A1 - Eigler, Siegfried T1 - Highly Emissive Hexa-peri-benzocoronene-fluoranthene Hybrid as Easily Processable and Stable OLED Material N2 - We report the synthesis of a fluorescent polycyclic aromatic hydrocarbon dye with a “symmetry-broken” core, derived from the related hexa-peri-benzocoronene (HBC) core with fluoranthene subunit. The fluorophore is composed of a pure Carbon skeleton without heteroatoms and exhibits remarkable photo luminescence properties with a photoluminescence Quantum yield (PLQY) of up to 67% in toluene, exceeding that of theparent HBC by a factor of 30. The single crystal X-ray structure reveals the distorted polycyclic aromatic hydrocarbon structure, which is responsible for the optoelectronic properties, as supported by density functional theory calculations. We show that the new fluorescent dye can be readily used for the fabrication of organic light-emitting diodes (OLED) without extensive optimization, whereby solubility in a variety of solvents and successful film formation are decisive. KW - Quantum Yield KW - OLED KW - Fluorescence KW - Synthesis PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-631298 DO - https://doi.org/10.1002/chem.202500742 SN - 1521-3765 SP - 1 EP - 7 PB - John Wiley & Sons, Inc AN - OPUS4-63129 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Frenzel, F. A1 - Fiedler, S. A1 - Bardan, A. A1 - Güttler, Arne A1 - Würth, Christian A1 - Resch-Genger, Ute T1 - Influence of Measurement Geometry and Blank on Absolute Measurements of Photoluminescence Quantum Yields of Scattering Luminescent Films N2 - For a series of 500 μm-thick polyurethane films containing different concentrations of luminescent and scattering YAG:Ce microparticles, we systematically explored and quantified pitfalls of absolute measurements of photoluminescence quantum yields (Φf) for often employed integrating sphere (IS) geometries, where the sample is placed either on a sample holder at the bottom of the IS surface or mounted in the IS center. Thereby, the influence of detection and illumination geometry and sample position was examined using blanks with various scattering properties for measuring the number of photons absorbed by the sample. Our results reveal that (i) setup configurations where the scattering sample is mounted in the IS center and (ii) transparent blanks can introduce systematic errors in absolute Φf measurements. For strongly scattering, luminescent samples, this can result in either an under- or overestimation of the absorbed photon flux and hence an under- or overestimation of Φf. The size of these uncertainties depends on the scattering properties of the sample and instrument parameters, such as sample position, IS size, wavelength-dependent reflectivity of the IS surface coating, and port configuration. For accurate and reliable absolute Φf measurements, we recommend (i) a blank with scattering properties closely matching those of the sample to realize similar distributions of the diffusely scattered excitation photons within the IS, and (ii) a sufficiently high sample absorption at the excitation wavelength. For IS setups with center-mounted samples, measurement geometries should be utilized that prevent the loss of excitation photons by reflections from the sample out of the IS. KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Quantum yield KW - Characterization KW - Silica KW - Scattering KW - Uncertainty KW - Film KW - Pphosphor KW - YAG:Ce KW - LED KW - Converter material KW - Solid material KW - Polymer KW - Composite material KW - Advanced material PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-638304 DO - https://doi.org/10.1021/acs.analchem.4c06726 SN - 1520-6882 SP - 1 EP - 8 PB - ACS Publications AN - OPUS4-63830 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tavernaro, Isabella A1 - Simon, Fabian A1 - Gehrenkemper, Lennart A1 - Tobias, Charlie A1 - Resch-Genger, Ute A1 - Meermann, Björn T1 - Quantification of the amount of surface groups of aminated silica nano- and microparticles utilizing a fluorine tag and HR-CS-GFMAS N2 - The performance, bioavailability, and safe use of engineered nanomaterials (NMs) depends not only on properties such as size, shape, and surface area, but largely on surface chemistry. While many sizing methods have been established, there is still a lack of validated screening methods for determining NM surface functional groups (FGs). In this context, we present a fast and simple method for FG quantification using high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and assess its applicability for the surface analysis of representatively chosen aminated silica nanoparticles (NPs) and microparticles (MPs) in conjunction with amino FG labeling with a fluorine tag. For this proof-of-concept study, first surface amino FG screening of the silica NPs and MPs was done with a potentiometric back titration method, providing the total amount of protonatable surface FGs, and two optical assays relying on reporter dyes with sizes and spatial requirements, i.e., surface binding areas smaller or larger than that of the fluorine tag to estimate the maximum and reporter-accessible number of amino FGs. Subsequently, the surface amino FGs were labeled with the fluorine tag 4-(trifluoromethyl)benzoic acid (TFMB) and the amount of fluorine originating from the bound TFMB molecules was quantified by HR-CS-GFMAS in two common organic solvents, i.e., dimethyl sulfoxide (DMSO) or ethanol (EtOH) to assess possible interferences from organic matrices. Our study revealed limits of detection (LODs) and quantification (LOQs) for fluorine of 1.0 µg/L and 3.5 µg/L in EtOH and 1.5 µg/L and 5.0 µg/L in DMSO, respectively. Overall, a quick and simple method for analyzing surface FGs on NPs and MPs was presented utilizing broadly available fluorine tags and HR-CS-GFMAS for fluorine quantification, which can be applied, e.g., for homogeneity, stability, and aging studies of surface-modified particles. This could contribute to ease the understanding of property-safety relationships for surface-functionalized NMs. KW - Fluorine Analysis KW - Nano- and microparticles KW - Surface group quantification PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-641965 DO - https://doi.org/10.1007/s00216-025-06107-4 SN - 1618-2642 SP - 1 EP - 11 PB - Springer Science and Business Media LLC CY - Berlin ; Heidelberg AN - OPUS4-64196 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharek, Vera M. A1 - Kröger, Tommy A1 - Keil, Karin A1 - Traub, Heike A1 - Meermann, Björn T1 - A new elemental analytical approach for microplastic sum parameter analysis—ETV/ICP-MS with CO2 N2 - Microplastics (MPs) are pervasive environmental pollutants and are considered one of the main challenges of our time. However, a fast and comprehensive analytical approach for MP analysis in complex matrices traceable to SI units is still lacking. In this context, we report a fast screening tool for the sum parameter analysis of MPs using electrothermal vaporization (ETV) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). In our proof-of-concept study, we observed size-independent detection of MPs as peaks above the 13C+ signal background in the nano- to micrometer range without limitations regarding the polymer type. Quantification of the 13C+ MP signals was accomplished via an external gas calibration utilizing dynamic dilution of carbon dioxide with argon, yielding recovery rates of 80–96% for MP reference material (RM) of polymer types commonly found in the environment. The applicability to a soil sample was demonstrated through spiking experiments with a polyethylene (PE) MP RM in soil. The limit of detection (LOD) was estimated to be 0.13 µg C, equaling the detection of a single spherical low-density-PE particle of about 70 µm, and a limit of quantification (LOQ) of 0.42 µg C. KW - ETV/ICP-MS KW - Mikroplastik KW - Summenparameter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646418 DO - https://doi.org/10.1007/s00216-025-06146-x SN - 1618-2642 SP - 1 EP - 10 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-64641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bayerl, C. A1 - Shahryari, M. A1 - Reiter, R. A1 - Proß, V. A1 - Lehmann, K. A1 - Kühl, A. A. A1 - Becker, Dorit A1 - Schulz, Andreas A1 - Infante Duarte, C. A1 - Taupitz, M. A1 - Geisel, D. A1 - Tzschätzsch, H. A1 - Saatz, Jessica A1 - Traub, Heike A1 - Asbach, P. T1 - Quantitative Analysis of Gadolinium Deposits in Liver Tissue of Patients After Single or Multiple Gadolinium-based Contrast Agent Application N2 - Gadolinium-based contrast agents (GBCAs) are widely used in magnetic resonance imaging. Concerns exist regarding gadolinium deposition and its potential histopathologic tissue alterations, especially after repeated administrations of linear, less stable GBCAs. This study aimed to quantify gadolinium mass fractions in liver specimens of subjects exposed to GBCAs in correlation with histopathologic features. In this study, mass fractions of gadolinium in human liver specimens from 25 subjects who underwent liver tumor resection surgery and had received GBCA (1 to 9 times over 4 years), were quantitatively analyzed using inductively coupled plasma–mass spectrometry (ICP-MS). Histomorphology was assessed based on the nonalcoholic fatty liver disease activity score (NAS). Our results suggest that after intravenous administration of GBCA, a small fraction of gadolinium is retained in the liver over a time period of at least several weeks. A relationship was observed between Gadolinium retention and the number of GBCA administrations, but not with the cumulative dose and the degree of fatty liver disease. KW - ICP-MS KW - Contrast agent KW - Gadolinium KW - Liver PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646608 DO - https://doi.org/10.1097/RLI.0000000000001254 SN - 1536-0210 SP - 1 EP - 10 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. AN - OPUS4-64660 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lozano-Martín, Daniel A1 - Tuma, Dirk A1 - Chamorro, César R. T1 - Evaluation of Reference Equations of State for Density Prediction in Regasified LNG Mixtures Using High-Precision Experimental Data N2 - This study evaluates the performance of three reference equations of state (EoS), AGA8-DC92, GERG-2008, and SGERG-88, in predicting the density of regasified liquefied natural gas (RLNG) mixtures. A synthetic nine-component RLNG mixture was gravimetrically prepared. High-precision density measurements were obtained using a single-sinker magnetic suspension densimeter over a temperature range of (250 to 350) K and pressures up to 20 MPa. The experimental data were compared with EoS predictions to evaluate their accuracy. AGA8-DC92 and GERG-2008 showed excellent agreement with the experimental data, with deviations within their stated uncertainty. In contrast, SGERG-88 exhibited significantly larger deviations for this RLNG mixture, particularly at low temperatures of (250 to 260) K, where discrepancies reached up to 3 %. Even at 300 K, deviations larger than 0.4 % were observed at high pressures, within the model’s uncertainty, but notably higher than those of the other two EoSs. The analysis was extended to three conventional 11-component natural gas mixtures (labeled G420 NG, G431 NG, and G432 NG), previously studied by our group using the same methodology. While SGERG-88 showed reduced accuracy for the RLNG mixture, it performed reasonably well for these three mixtures, despite two of them have a very similar composition to the RLNG. This discrepancy is attributed to the lower CO2 and N2 content typical in RLNG mixtures, demonstrating the sensitivity of EoS performance to minor differences in composition. These findings highlight the importance of selecting appropriate EoS models for accurate density prediction in RLNG applications. KW - Regasified LNG KW - Equation of state KW - Density KW - Gravimetric preparation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646506 DO - https://doi.org/10.1007/s10765-025-03669-4 SN - 0195-928X VL - 46 SP - 1 EP - 25 PB - Springer Science and Business Media LLC CY - Heidelberg AN - OPUS4-64650 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Heide, Maximilian A1 - Reifenrath, Jonas A1 - Herrmann, Alexander A1 - Engelhard, Carsten T1 - Fast and Sustainable Active Pharmaceutical Ingredient (API) Screening in Over-the-Counter and Prescription Drug Products by Surface-Assisted Plasma-Based Desorption/Ionization High-Resolution Mass Spectrometry N2 - Fast chemical analysis of pharmaceutical preparations is important for quality assurance, counterfeit drug detection, and consumer health. While quantitative methods such as high-performance liquid chromatography mass spectrometry (HPLC-MS) are powerful, there is a need for sustainable and environmentally friendly methods, which require less chemicals and produce less waste. Here, solvent-free ambient desorption/ionization (ADI) MS methods are attractive because they do not require time-consuming chromatography, produce little to no chemical waste, and, thus, contribute to green chemistry practice. In addition, sample throughput can be higher compared to HPLC-MS. In this study, a method for direct analysis of single- and multi agent drugs using a plasma-based ADI source (flowing atmospheric-pressure afterglow, FAPA) coupled to high-resolution (HR) MS was developed and optimized for best performance. The approach is rapid and only requires analytes to be in solution (only a few µL) before application onto thin-layer chromatography (TLC) surfaces, specifically dimethyl (RP2-) and cyano (CN-) modified silica, for surface-assisted (SA) FAPA-HRMS measurements. No chromatographic separation was required, and the TLC plates served only as sample carriers. A broad variety of 19 active pharmaceutical ingredients (APIs) was carefully selected to cover analgesics, anesthetics, antibiotics, antiepileptics, calcium channel blockers, diuretics, expectorants, opioids, peripheral vasodilators, stimulants, and sympathomimetics. Fast screening and identification of APIs was performed by SA-FAPA-HRMS. Typically, the protonated molecular ion ([M+H]+) was the most abundant species, while some compounds (codeine, metamizole, phenoxymethylpenicillin, and torasemide) did show some degree of fragmentation. As a proof-of-principle application, benzocaine was directly detected in saliva samples post-intake of a lozenge. Time-resolved semi-quantitative screening was performed. The limit of detection for benzocaine in saliva was 8 ng/mL (48.4 fmol) using internal standard calibration and CN-HPTLC plates. In addition, direct quantification of artificially spiked saliva was performed with minimal sample preparation. Here, SA-FAPA-HRMS with a CN-HPTLC sample substrate yielded best performance (20.02±0.52 µg/mL, RSD=2.6%, deviation of -1.9% from the theoretical value) compared to RP2-TLC (18.97±1.37 µg/mL, RSD=7.2%, -7.0%), and HPLC-UV (18.51±0.03 µg/mL, RSD=0.2%, -9.3%) results. In conclusion, SA FAPA HRMS is considered attractive for rapid and sustainable analysis of pharmaceuticals with potential in non-invasive patient monitoring. KW - Mass Spectrometry KW - Pharmaceuticals KW - Green Chemistry KW - Ambient Desorption/Ionization PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640718 DO - https://doi.org/10.1039/D5AY01050K SN - 1759-9660 VL - 17 IS - 18 SP - 7799 EP - 7809 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64071 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -