TY - CONF A1 - Hosseini, Seyed M. H. A1 - Heckel, Thomas A1 - Boehm, Rainer A1 - Brackrock, Daniel A1 - Gohlke, Dirk A1 - Riemer, Stefanie A1 - Gaal, Mate T1 - Gegenüberstellung der Performance verschiedener Ultraschallsensorsysteme bei der Untersuchung von CFK-Platten T1 - Comparison of performance of different ultrasonic systems for inspection of CFRP plates N2 - Die Zahl der industriellen Anwendungen mit Einsatz von Faserverbundwerkstoffen wächst kontinuierlich vor allem wegen der exzellenten Materialeigenschaften und des geringen Gewichtes dieses Werkstoffes. Entsprechend steigen die Anforderungen an zerstörungsfreie Prüfsysteme zur Gewährleistung des sicheren Betriebes von Komponenten und Strukturen bestehend aus Verbundwerkstoffen. Im Rahmen des EU-Projekes VITCEA (Validated Inspection Techniques for Composites in Energy Applications) wird das Ziel verfolgt, neue Prüfverfahren für moderne Verbundwerkstoffe zu entwickeln und zu validieren. Im Vordergrund steht hierbei als Applikation im Industriesektor Energieversorgung die Prüfung von sicherheitsrelevanten Komponenten von onshore und offshore Windkraftanlagen, wie z.B. deren Rotorblätter und tragende Strukturen. Eine Teilaufgabe innerhalb des Projektes stellen der Vergleich und die Validierung verschiedener Ultraschallprüfmethoden bezüglich ihrer Fähigkeit zum Nachweis der typischen Herstellungs- und betriebsbedingten Materialschädigungen von CFK und GFK dar. Neben verschiedenen konventionellen Ultraschall-Prüftechniken, werden die Phased-Array-Prüfung, insbesondere die Prüfung mit Matrixarrays, sowie die Untersuchung mit berührüngsloser Luftultraschalltechnik bezüglich ihrer Nachweisgrenzen und der Möglichkeiten zur Fehlercharakterisierung an Faserverbundwerkstoffen untersucht. Die Ergebnisse werden mit Untersuchungen mit thermographischen Methoden und Mikrowellentechnik verglichen. N2 - Applications of fiber-reinforced plastic (FRP) composites in modern industries are increasing due to their considerable advantages such as light weight and excellent mechanical properties. Accordingly, importance of operational safety of modern structures made of advanced composites by ensuring the material quality has led to increasing demands for development of non-destructive evaluation (NDE) systems. In the context of a European-project entitled 'Validated Inspection Techniques for Composites in Energy Applications' (VITCEA), the aim is to develop and validate traceable procedures for novel NDE techniques with contrasting damage detection capabilities in energy related applications such as wind and marine turbine blades, nacelles, oil and gas flexible risers. As a part of VITCEA, the present study focuses on application of ultrasonic tests (UTs) including conventional, matrix array, immersion and air-coupled, for quantitative defect detection and quality characterization of FRP structures. Results of UTs are subjected to be compared with other NDE approaches which are applicable for inspection of FRPs such as thermography and microwave techniques. Within the present report, the initial results obtained from conventional and immersion UTs are presented and their capabilities as well as limitations are discussed. In order to validate theoretical predictions and simulation results, further experimental tests will be performed in the framework of the project using reference defect artefacts in which the defect sizes and locations are well defined and controlled. T2 - DGZfP Seminar des Fachausschusses Ultraschallprüfung CY - Saarbrücken, Germany DA - 03.11.2015 KW - Ultraschallsensorsysteme KW - Faserverbundwerkstoffe KW - Kontakttechnik Technik KW - Tauchtechnik KW - Phased-Array-Prüfung KW - Luftultraschall PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-349264 UR - https://www.dgzfp.de/Portals/ultraschall2015/BB/3.pdf SP - Vortrag 3, 1 EP - 10 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-34926 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Viefhues, Eva A1 - Döhler, M. A1 - Hille, Falk A1 - Mevel, L. T1 - Fault detection for linear parameter varying systems under changes in the process noise covariance N2 - Detecting changes in the eigenstructure of linear systems is a comprehensively investigated subject. In particular, change detection methods based on hypothesis testing using Gaussian residuals have been developed previously. In such residuals, a reference model is confronted to data from the current system. In this paper, linear output-only systems depending on a varying external physical parameter are considered. These systems are driven by process noise, whose covariance may also vary between measurements. To deal with the varying parameter, an interpolation approach is pursued, where a limited number of reference models – each estimated from data measured in a reference state – are interpolated to approximate an adequate reference model for the current parameter. The problem becomes more complex when the different points of interpolation correspond to different noise conditions. Then conflicts may arise between the detection of changes in the eigenstructure due to a fault and the detection of changes due to different noise conditions. For this case, a new change detection approach is developed based on the interpolation of the eigenstructure at the reference points. The resulting approach is capable of change detection when both the external physical parameter and the process noise conditions are varying. This approach is validated on a numerical simulation of a mechanical system. T2 - 21st IFAC World Congress CY - Online meeting DA - 13.07.2020 KW - Linear parameter varying systems KW - Fault detectionchanging KW - Process noise KW - Subspace-based residual KW - Model interpolation PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-524652 DO - https://doi.org/10.1016/j.ifacol.2020.12.868 SN - 2405-8963 VL - 53 IS - 2 SP - 13668 EP - 13673 PB - Elsevier AN - OPUS4-52465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüllmann, Dino A1 - Kohlhoff, Harald A1 - Neumann, Patrick P. ED - Bársony, I. ED - Zolnai, Z. ED - Battistig, G. T1 - Embedded control of a PMSM servo drive without current measurements N2 - A permanent-magnet synchronous motor (PMSM) servo drive for lightweight robotic platforms that have a high torque demand at low rotational speeds has been developed. First, a current-independent torque controller is derived and cascaded with a speed and position controller, while merely an encoder is used as a sensor device in combination with a speed estimator. Finally, the speed estimator output is compared to gyroscope measurements and the overall functioning is verified on a real system. T2 - 30th Eurosensors Conference - Eurosensors 2016 CY - Budapest, Hungary DA - 04.09.2016 KW - BLDC KW - PMSM KW - Motor control KW - Servo drive KW - Optical incremental encoder PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-388973 DO - https://doi.org/10.1016/j.proeng.2016.11.487 SN - 1877-7058 VL - 168 SP - 1671 EP - 1675 PB - Elsevier B.V. CY - Amsterdam, Netherlands AN - OPUS4-38897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pfennig, Anja A1 - Wolf, Marcus A1 - Gröber, Andre A1 - Böllinghaus, Thomas A1 - Kranzmann, Axel T1 - Corrosion fatigue of 1.4542 exposed to a laboratory saline aquifer water CCS-environment N2 - X5CrNiCuNb16-4 has been proven to be sufficient resistant in corrosive environments, but shows rather unusual corrosion behaviour in CCS environment. Therefore a series of 30 specimens was tested at stress amplitudes between 150 MPa and 500 MPa (sinusoidal dynamic test loads, R=-1; resonant frequency ∼ 30 Hz). Due to the rather heterogeneous fine machined surfaces (Rz=4) the specimens are comparable with prefabricated parts. X5CrNiCuNb16-4 reached the maximum number of cycles (10 x 106) at a stress amplitude of 150 MPa and lies 60% below the stress amplitude measured in air. The scatter range TN = 1:34 is disproportionately large. Although the fracture surface exhibited the typical striations and corroded surface areas no significant differences were found. The hardness was found to be homogeneous in all specimens tested at 335 HV10. Non-metallic inclusions were found within the microstructure, but no correlation could be found between the inclusions and early rupture. Still specimens that showed inclusions at the fracture surface and its cross section endured lower number of cycles. Additionally Aluminium was analysed in specimens with low number of cycles and may be cause for early rupture during corrosion fatigue tests. These findings reveal a very high sensitivity on a homogeneous microstructure upon the corrosion and corrosion fatigue behaviour of X5CrNiCuNb16-4 and needs to be taken into account when regarding this steel as pipe steel during injection of CO2 into saline aquifers. T2 - 13th International Conference on Greenhouse Gas Control Technologies CY - Lausanne, Switzerland DA - 14.11.2016 KW - Steel KW - Corrosion fatigue KW - Electrochemistry KW - Reliability KW - CCS KW - CO2-storage PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-418525 DO - https://doi.org/10.1016/j.egypro.2017.03.1678 SN - 1876-6102 VL - 114 SP - 5219 EP - 5228 AN - OPUS4-41852 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kromm, Arne A1 - Rhode, Michael A1 - Launert, B. A1 - Dixneit, Jonny A1 - Kannengießer, Thomas A1 - Pasternak, H. ED - Olden, T.-M. ED - Muransky, O. ED - Edwards, L. T1 - Combining sectioning method and X-ray diffraction for evaluation of residual stresses in welded high strength steel components N2 - Residual stresses and distortions in welded I-girders for steel construction are relevant when evaluating the stability of steel beams and column members. The application of high strength steels allows smaller wall thicknesses compared to conventional steels. Therefore, the risk of buckling has to be considered carefully. Due to the lack of knowledge concerning the residual stresses present after welding in high strength steel components conservative assumptions of their level and distribution is typically applied. In this study I-girders made of steels showing strengths of 355 MPa and 690 MPa were welded with varying heat input. Due to the dimension of the I-girders and the complex geometry the accessibility for residual stress measurement using X-ray diffraction was limited. Therefore, saw cutting accompanied by strain gauge measurement has been used to produce smaller sections appropriate to apply X-ray diffraction. The stress relaxation measured by strain gauges has been added to residual stresses determined by X-ray diffraction to obtain the original stress level and distribution before sectioning. The combination of both techniques can produce robust residual stress values. From practical point of view afford for strain gauge application can be limited to a number of measuring positions solely to record the global amount of stress relaxation. X-ray diffraction can be applied after sectioning to determine the residual stresses with sufficient spatial resolution. T2 - ICRS 2016 - 10th International Conference on Residual Stresses CY - Sydney, Australia DA - 03.07.2016 KW - Welding KW - Residual Stress KW - Sectioning Method KW - X-Ray Diffraction KW - Component Testing PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-389206 SN - 978-1-94529117-3 SN - 978-1-94529117-6 DO - https://doi.org/10.21741/9781945291173-28 SN - 2474-395X VL - 2 SP - 163 EP - 168 PB - Materials Research Forum LLC CY - Millersville (PA), USA AN - OPUS4-38920 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - D'Accardi, E. A1 - Ulbricht, Alexander A1 - Krankenhagen, Rainer A1 - Palumbo, D. A1 - Galietti, U. T1 - Capability of active thermography to detect and localize pores in Metal Additive Manufacturing materials N2 - Active thermography is a fast, contactless and non-destructive technique that can be used to detect internal defects in different types of material. Volumetric irregularities such as the presence of pores in materials produced by the Additive Manufacturing processes can strongly affect the thermophysical and the mechanical properties of the final component. In this work, an experimental investigation aimed at detecting different pores in a sample made of stainless AISI 316L produced by Laser Powder Bed Fusion (L-PBF) was carried out using pulsed thermography in reflection mode. The capability of the technique and the adopted setups in terms of geometrical and thermal resolution, acquisition frequency and energy Density of the heating source were assessed to discern two contiguous pores as well as to detect a single pore. Moreover, a quantitative indication about the minimum resolvable pore size among the available and analysed defects was provided. A powerful tool to assess the Limits and the opportunities of the pulsed technique in terms of detectability and localizability was provided by comparing active thermography results to Computed Tomography as well as a related Finite Element Analysis (FEA) to simulate the pulsed heating transfer with Comsol. T2 - 49th Italian Association for Stress Analysis Conferencee (AIAS 2020) CY - Online meeting DA - 02.09.2020 KW - Additive manufacturing KW - Laser powderbed fusion KW - Pores KW - Thermography KW - Micro-CT PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-519231 DO - https://doi.org/10.1088/1757-899X/1038/1/012018 VL - 1038 SP - 1 EP - 17 PB - Institute of Physics CY - London AN - OPUS4-51923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Burgholzer, P. A1 - Berer, T. A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Ahmadi, Samim A1 - Gruber, J. A1 - Mayr, G. A1 - Hendorfer, G. T1 - Blind structured illumination as excitation for super-resolution photothermal radiometry N2 - Using an infrared camera for radiometric imaging allows the contactless temperature measurement of multiple surface pixels simultaneously. From the measured surface data, a sub-surface structure, embedded inside a sample or tissue, can be reconstructed and imaged when heated by an excitation light pulse. The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The ground-breaking concept of super-resolution can be transferred from optics to thermographic imaging. T2 - Conference QIRT 2018 CY - Berlin, Germany DA - 25.06.2018 KW - Thermography KW - Laser thermography KW - Super resolution PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-454506 SN - 978-3-940283-94-8 DO - https://doi.org/10.1080/17686733.2019.1655247 SP - We.3.A.2, 1 EP - 7 AN - OPUS4-45450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüsken, Götz A1 - Wagner, L.-C. A1 - Gluth, Gregor A1 - Pirskawetz, Stephan A1 - Kühne, Hans-Carsten T1 - Application of Steel Fibres in Alkali-Activated Mortars N2 - Alkali-activated materials are ideal for the repair of concrete structures in harsh environmental conditions due to their high durability in chemically aggressive environments. However, slag-based mortars, in particular, are prone to shrinkage and associated cracks. In this respect, the application of steel fibres is one solution to reduce the formation of shrinkage induced cracks and to improve post cracking behaviour of these mortars. This study investigated the influence of two different types of steel fibres on the tensile properties of two alkali-activated mortars. Direct tensile tests and single fibre pull-outs were performed to analyse the determining failure modes both on macro and micro scale. Mechanical testing was accompanied by non-destructive testing methods such as digital image correlation and acoustic emission for a detailed analysis of the fracture process. T2 - Local Mechanical Properties - LMP 2019 CY - Prague, Czech Republic DA - 06.11.2019 KW - Alkali-activated materials KW - Fibre pull-out KW - Steel fibres KW - Tensile strength PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509291 UR - https://ojs.cvut.cz/ojs/index.php/APP/article/view/6695 DO - https://doi.org/10.14311/APP.2020.27.0090 VL - 27 SP - 90 EP - 95 CY - Prague, Czech Republic AN - OPUS4-50929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Metz, Christian A1 - Franz, Philipp A1 - Fischer, C. A1 - Wachtendorf, Volker A1 - Maierhofer, Christiane T1 - Active thermography for quality assurance of 3D-printed polymer structures N2 - Additively manufactured test specimens made of polyamide 12 (PA 12) by Laser Sintering (LS) as well as of acrylnitril-butadien-styrol (ABS) by Fused Layer Modeling (FLM), were tested with active thermography. For this, two different excitation methods (flash and impulse excitation) were used and compared, regarding the suitability for the detection of constructed and imprinted defects. To increase the quality of the thermograms, data processing methods like thermal signal reconstruction (TSR) and Fourier-Transformation were applied. Furthermore, the long-term stability of the probes towards environmental stress, like UV-radiation, heat, water contact and frost is being investigated in the presented project with artificial weathering tests. T2 - 14th Quantitative InfraRed Thermography Conference CY - Berlin, Germany DA - 25.06.2018 KW - Additive manufacturing KW - Active thermography KW - Artificial weathering PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-453919 SP - Tu.3.A.2, 1 EP - 9 AN - OPUS4-45391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kemmler, Samuel A1 - Cuéllar, Pablo A1 - Rettinger, C. A1 - Köstler, H. T1 - A Fluid-Solid Coupled Micromechanical Simulation for the Analysis of Piping Erosion During the Seabed Installation of a Suction Bucket Foundation N2 - Suction buckets are a promising concept for the foundations of offshore wind turbines. During the installation process of a suction bucket, localized fluidization of the granular soil, so-called piping erosion, may lead to installation failure. A 3D fluid-solid coupled micromechanical simulation is presented to study the occurrence of piping. An Euler-Lagrangian coupling employs momentum exchange between the fluid phase and the geometrically resolved particles. We investigate the behavior of the soil for three cases with varying prescribed suction velocities. We observe piping in the case with the highest suction velocity by analyzing the deformation of the granular fabric and monitoring the differential pressure. The grains under the bucket wall-tip show the highest hydraulic gradients and forces at the onset of piping. This approach permits a detailed analysis of piping phenomena and brings novel insights on the triggering conditions for piping failure of suction-aided foundations. T2 - TC 105 International Symposium CY - Grenoble, France DA - 23.09.2024 KW - Micromechanical simulation KW - Piping erosion KW - Suction bucket foundation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-629461 DO - https://doi.org/10.1088/1755-1315/1480/1/012024 SN - 1755-1307 VL - 1480 IS - 1 SP - 1 EP - 4 PB - IOP Publishing AN - OPUS4-62946 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -