TY - CONF A1 - Sötebier, Carina T1 - Analysis of Silver Nanoparticles Using AF4 Coupled to ICP-MS: Investigating Sample Loss and Recovery Rates T2 - 10th International Conference on the Environmental Effects of Nanoparticles and Nanomaterials ICEENN 2015 CY - Vienna, Austria DA - 2015-09-06 PY - 2015 AN - OPUS4-34098 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sötebier, Carina T1 - Analysis of Silver Nanoparticles Using AF4 Coupled to ICP-MS: Investigating Sample Loss and Recovery Rates T2 - 3rd Workshop on Field-Flow Fractionation - Mass Spectrometry CY - Vienna, Austria DA - 2015-09-05 PY - 2015 AN - OPUS4-34106 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Ralph-Peter T1 - Beiträge zur Charakterisierung von synthetischen Si-Polymeren durch Kopplung von HPLC-Trennmethoden mit der MALDI-TOF-MS T2 - InCom´01 CY - Düsseldorf, Germany DA - 2001-03-27 PY - 2001 AN - OPUS4-3351 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Ralph-Peter T1 - Charakterisierung von synthetischen Polymeren durch Kopplung flüssigchromato-graphischer Trennmethoden mit der MALDI-TOF-Massenspektrometrie T2 - 1. Berliner Werkstofftag CY - Berlin, Germany DA - 1999-09-16 PY - 1999 AN - OPUS4-3444 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Liquid Chromatography at Critical Conditions - advantages and shortcomings T2 - Arbeitskreis Polymeranalytik CY - Fraunhofer-Institut für Betriebsfestigkeit und Systemzuverlässigkeit LBF Darmstadt DA - 2015-03-20 PY - 2015 AN - OPUS4-32937 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Characterization of polylactides by coupling of chromatographic methods with MALDI-TOF-MS T2 - ISPAC CY - Enschede, Netherlands DA - 2002-06-17 PY - 2002 AN - OPUS4-3454 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Challenges of SEC and the necessity of round robin tests N2 - Size exclusion chromatography (SEC) is still the method of choice for determining the molar mass and molar mass distribution of macromolecules. It is a liquid chromatographic technique that separates molecules based on their size, respectively their hydrodynamic volume using a porous stationary phase that allows smaller molecules to pass through the pores while excluding larger molecules. The chromatogram from the size separation can be calibrated using polymers of known molar mass resulting in a relative molar mass distribution curve. From this distribution curve molar mass averages and the oligomer content (percentage of peak area smaller than 1000 g/mol and 500 g/mol) of polymers can be derived. The determination of oligomer content is important, because it is often used in regulatory contexts as a measure of small, mobile and potentially more toxic parts of the polymer. Polymer regulations are of increasing political and societal importance. Regulations often strive for narrow limits. But SEC has rather large error margins of 10-20% for the molar mass determination performed in different laboratories or on different instruments. These variances are well known to all experts and users and have been investigated in several round robin tests in the past. These resulted in DIN and ISO standards which, in our opinion, no longer meet today's requirements. Gaps have been identified that require further harmonization. Different polymer types or classes require different methods. On the other hand, as far as we know, the margins of error in determining oligomer content have not yet been investigated. It is expected that the variation will be rather high. This is because it depends on many factors related to the experimental conditions (column sets used, solvent, temperatures, sample preparation) on the one hand, and the data evaluation mechanisms (choice of baseline and peak limits) on the other. In order to actually measure the error margins and to support this with actual data a round robin test has been performed from June to November 2024 with approx. 40 participating laboratories. Three different solvents were selected, namely THF, DMAc or DMF and water. The samples were selected taking into account a wide range of practical aspects far from narrowly distributed standards: e.g higher distribution range, reduced solubility, included side components, copolymers and dispersions with gel content. In this contribution we will present the detailed concept of this round robin test and first impressions. T2 - 11th International Symposium on the Separation and Characterization of Natural and Synthetic Macromolecules CY - Amsterdam, Netherlands DA - 21.01.2025 KW - Size exclusion chromatography KW - Round robin tests PY - 2025 AN - OPUS4-62533 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Error margins in the Determination of Molar Mass and Oligomer Content of Polymers N2 - Size exclusion chromatography (SEC) is still the method of choice for determining the molar mass and molar mass distribution of macromolecules. It is a liquid chromatographic technique that separates molecules based on their size, respectively their hydrodynamic volume using a porous stationary phase that allows smaller molecules to pass through the pores while excluding larger molecules. The chromatogram from the size separation can be calibrated using polymers of known molar mass resulting in a relative molar mass distribution curve. From this distribution curve molar mass averages and the oligomer content (percentage of peak area smaller than 1000 g/mol and 500 g/mol) of polymers can be derived. The determination of oligomer content is important, because it is often used in regulatory contexts as a measure of small, mobile and potentially more toxic parts of the polymer. Polymer regulations are of increasing political and social importance. Regulations often set very narrow limits. SEC has rather large error margins of 10-20% for the molar mass determination performed in different laboratories or on different instruments. These variances are well known to all experts and users and have been investigated in several round robin tests in the past. These resulted in DIN and ISO standards which, in our opinion, no longer meet today's requirements. As far as we know, the margins of error in determining oligomer content have not yet been investigated. It is expected that the variation will be rather high. This is because it depends on many factors related to the experimental conditions (column sets used, solvent, temperatures, sample preparation) on the one hand, and the data evaluation mechanisms (choice of baseline and peak limits) on the other. In order to actually measure the error margins and to support this with actual data a round robin test has been performed from June to November 2024 with approx. 40 participating laboratories. Three different solvents were selected, namely THF, DMAc or DMF and water. The samples were selected together with all the experts, taking into account a wide range of practical aspects far from narrowly distributed standards: e.g higher distribution range, reduced solubility, included side components, copolymers and dispersions with gel content. In this contribution we will present the detailed concept of this round robin test and first results. T2 - SETAC Europe 35th Annual Meeting CY - Vienna, Austria DA - 11.05.2025 KW - Size exclusion chromatography KW - REACH KW - Polymers KW - Round Robin Tests PY - 2025 AN - OPUS4-63307 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - 30 years LC-MS of synthetic macromolecules – an old story or something left to discover? N2 - Structure elucidation of complex synthetic copolymers still represents a challenge. A one-dimensional separation technique cannot give the answer to the question: What are the molar mass distribution (MMD), the functionality distribution (FTD), the chemical composition distribution (CCD), the monomer sequence distribution (MSD), the topology differences within a single broad distributed polymer sample? Is the coupling of liquid chromatographic separation techniques to mass spectrometry able to fill the gaps to a certain degree? Different LC separation techniques as size exclusion chromatography (SEC), liquid adsorption chromatography (LAC), liquid chromatography at critical conditions (LCCC) and gradient elution liquid chromatography (GELC) combined with Matrix assisted Laser Desorption Ionization (MALDI) respectively Electrospray Ionization (ESI) Time of Flight (TOF) mass spectrometry are able to give information which otherwise are completely inaccessible. In some cases, CID tandem mass spectrometry is applied. Fragmentation of suitable precursor ions resulted in typical fragment ion patterns. This technique enables an additional information on e.g. sequences, structural defects and topology of complex polymer mixtures. Often the deficiencies of stand-alone methods can be bridged. LC, blind to structural information needs mass spectrometry as one of the most powerful detectors able to give detailed information on e.g. the repeat units, functionalization or copolymer composition of the chromatographic separated constituents. A separation prior to MS reduces radical the dispersity which is one of the reasons for failing of MS. Also problems with different ionization probabilities in complex mixtures can partly be overcame. The lecture will provide a series of examples where LC-MS has been applied to evaluate complex macromolecules and mixtures of these. On- and offline coupling principles will be compared and the pros and cons of both mass spectrometric techniques will be discussed. T2 - SCM-8; International Symposium on the CY - Amsterdam, The Netherlands DA - 30.01.2017 KW - Characterization of polymers KW - HPLC KW - UPLC/ESI-TOF-MS KW - LC/MALDI-TOF-MS KW - Coupling techniques PY - 2017 AN - OPUS4-39276 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - You, Zengchao T1 - Nanoparticles separation using capillary electrophoresis N2 - Nowadays, different nanoparticles have been developed for commercial applications. However, since data on toxicity are barely available, their increasing application in cosmetic products, food and their release in the environment might cause severe problems. An accurate separation, identification and characterization of nanoparticles becomes increasingly important. A common method for nanoparticle separation, which was introduced in 1976 by Giddings, represents asymmetrical field-flow fractionation (AF4). It is a flow based separation method, which can be theoretically used to separate particles range from 1 nm to 50 µm. However, when the particles are smaller than 10 nm, separation with AF4 will become difficult to perform. Because in this case strong separation force, which induces aggregation of particles, should be applied. This will decrease recoveries of analytes and limit its application in accurate quantitative analysis. Capillary electrophoresis (CE) is another well-developed separation technique, in which samples will be separated in relation to their electrophoretic mobility. In recent years, CE has been used to separate different kinds of nanoparticles like, gold colloids or CdSe Quantum dots. However, till now only separation of particles smaller than 50 nm was reported. Because large size distribution of bigger particles will result in strong peak broadening and long separation time. A two-dimensional coupling of AF4 and CE might provide us a new separation method, which can extend the separation ranges of both methods and be a way to characterise particles with large size distributions. T2 - ESAS-CANAS Konferenz CY - Berlin, Germany DA - 21.03.2018 KW - Nanoparticles separation capillary electrophoresis asymmetrcial flow field flow fractionation PY - 2018 AN - OPUS4-47188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Ralph-Peter T1 - Beiträge zur Charakterisierung von synthetischen Si-Polymeren durch Kopplung von HPLC-Trennmethoden mit der MALDI-TOF-Massenspektrometrie T2 - Berliner Polymerentage 2000 CY - Berlin, Germany DA - 2000-10-09 PY - 2000 AN - OPUS4-3388 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Coupling techniques for copolymer characterization with focus on LC-MC T2 - ISPAC, 26th Int. Symposium on Polymer Analysis and Characterization CY - New Orleans, LA, USA DA - 2013-06-09 PY - 2013 AN - OPUS4-28631 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hoskins, Jessica T1 - MALDI-TOF MS of Hyperbranched Polymers Aided by Liquid Chromatography Separation T2 - American Society for Mass Spectrometry Annual Conference 2013 CY - Minneapolis, MN, USA DA - 2013-06-08 PY - 2013 AN - OPUS4-28782 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sötebier, Carina T1 - Characterization of Ag nanoparticles: limitation and advantages of field-flow fractionation N2 - Silver nanoparticles (Ag NPs) are widely used in consumer products due to their excellent antibacterial properties. Their broad application has led to a variety of recent regulation on their use and labelling. Thus, a highly specific analytical method for their characterization and quantification is needed. Due to their large separation range, field-flow fractionation (FFF) techniques are repeatedly applied for the analysis of NP. Limitations of FFF include quantification, sample loss and insufficient recovery rates. Another challenge can be non-ideal elution behavior of particles in complex and unknown matrices. The possible sources for sample losses of Ag NP have been studied using an asymmetric flow FFF (AF4) in combination with inductively coupled plasma mass spectrometry (ICP-MS). The influence of different parameters, for example the sample concentration, on the recovery rates and sample loss has been investigated. Using laser ablation ICP-MS, the Ag deposition on the membrane was located and quantified. Our results identified ionic silver as the main sources of sample loss. These results can be useful for further method improvement. However, when a Ag NP sample containing an unknown complex matrix is analyzed, FFF method optimization is challenging as the sample might show a shift in the retention times and lower recovery rates. In this case, ICP-MS experiment in the single particle mode (sp-ICP-MS) can be a useful addition to the FFF measurement. Here, upon assumption of spherical particles, the geometric diameters can be calculated. This fast and easy approach can be helpful in order to interpret the FFF fractograms and advice the FFF method optimization process. T2 - 18th International Symposium on Field- and Flow-Based Separations CY - Dresden, Germany DA - 22.05.2016 KW - Silver KW - Nanoparticles KW - Field-flow fractionation KW - ICP-MS PY - 2016 AN - OPUS4-36352 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zeegers, G. P. T1 - Evidence for laser-induced redox reactions between added trifluoroacetate salts and substrate material during polystyrene/DCTB MALDI N2 - Polymers, such as polystyrene, have been successfully analyzed with matrix-assisted laser desorption/ionization (MALDI) through the addition of e.g. copper or silver salts. This method is often used to establish the polydispersity index of polymer blends. However, the mechanism of cation addition and the possible interactions between the added salts and the chosen target material are still points of interest. Therefore, the addition of several trifluoroacetate salts to a mixture of polystyrene and matrix on a range of different target plate materials was systematically investigated, revealing several new interesting aspects of MALDI. Polystyrene (Mw 1,920 Da) was mixed with a range of trifluoroacetate salts (Li, Na, K, Cs, Ba, Cr, Pd, Cu, Ag, Zn, Al and In, as well as trifluoroacetic acid) and analyzed with MALDI using 2 -[2E-3-4-tert-butylphenyl)- 2- methylprop-2-enylidene]ma lononitrile DCTB) as matrix on different target plate materials (chrome, copper, silver, gold, Ti90/Al6/V4, Inconel® 625, Zinc and stain less steel) to evaluate the occurrence of redox-reactions. Polystyrene/salt/matrix solutions were deposited through pneumatic-assisted spraying on microscope slide -shaped target plate insets of varying material, which, secured with copper tape, fitted a milled out structure from the original target plate. Spectra, obtained on a Bruker Autoflex I MALDI-Time -of-Flight mass spectrometer, were processed with MATLAB to obtain polystyrene-and matrix -adduct ion signal intensities for direct comparison between chosen conditions. The resulting spectra shed light on the MALDI adduct formation process and the cation-polystyrene interactions. It was found that the following cation -polystyrene adducts were formed on stainless steel: Al, Li, Na, Cu and Ag, where the yield was found to depend on the sample layer thickness and possibly the cation’s ability to form a complex with either one or two of polystyrene’s phenyl rings, based on the ligand-field and the valence bond theory. With the exception of Al, these salts also formed adducts and in case of Cu and Ag also sandwich adducts with DCTB. Some alkali salts (e.g. potassium) formed clusters rather than interacting with polystyrene or DCTB, which can be explained with the HSAB theory. Application of TFA salts on a copper surface led to copper cation formation, resulting in DCTB and polystyrene copper-adduct formation. The same effect occurred for silver substrate. In the absence of copper or silver salts, it is therefore still possible to form their respective adducts by choosing the proper alternative salt (e.g. Li, Cs, Ba, Cr) in combination with either a silver or a copper substrate surface. Incubation tests with copper beads in various salt solutions, before matrix and polystyrene addition, support that copper ions are not generated during the deposition process before the MALDI experiment is carried out, except when trifluoroacetic acid, indium and aluminium trifluoroacetate are used. For all other salts used on a copper plate, it can therefore be concluded that these copper cation forming redox-reactions are enabled by the input of laser photon energy. Furthermore, it was discovered that copper beads can successfully sequester polystyrene from the sample mixture, indicating the strong bonding of polystyrene to the copper surface. These findings support that the redox-reactions occur (almost) instantaneously with laser pulse impact at the sample-coated substrate surface. T2 - Jahrestagung der DGMS 2016 CY - Hamburg, Germany DA - 28.02.2016 KW - MALDI KW - Redox-reactions KW - Substrate KW - Cations PY - 2016 AN - OPUS4-36937 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Synthesis of Polylactides and thier characterization by coupling of liquid chromatographic mathods with MALDI-TOF-MS T2 - 7th International Symposium on Polymers for Advanced Technologies CY - Fort Lauderdale, FL, USA DA - 2003-09-21 PY - 2003 AN - OPUS4-3542 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Ralph-Peter T1 - Zur Chracterisierung von bioabbaubaren Polyestern durch Kopplung von chromatographischen Methoden mit der MALDI-Flugzeitmassenspektrometrie T2 - 11. Internationale Fachtagung Polymerwerkstoffe 2004 CY - Halle (Saale), Germany DA - 2004-09-29 PY - 2004 AN - OPUS4-3540 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Ralph-Peter T1 - Calixarene in Photoresisten (Kopplung von flüssigchromatographischen Methoden mit der MALDI-TOF-MS) T2 - Fachgruppenvollversammlung BAM CY - Berlin, Germany DA - 2002-01-29 PY - 2002 AN - OPUS4-3418 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Ralph-Peter T1 - Zur Synthese und Charakterisierung von Polylactiden T2 - Analytica Conference 2004 CY - Munich, Germany DA - 2004-05-11 PY - 2004 AN - OPUS4-3539 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - You, Zengchao T1 - Nanoparticles separation using capillary electrophoresis (CE) and asymmerical flow-field flow fractionation (AF4) N2 - Nowadays, different nanoparticles have been developed for commercial applications. However, since data on toxicity are barely available, their increasing application in cosmetic products, food and their release in the environment might cause severe problems. An accurate separation, identification and characterization of nanoparticles becomes increasingly important. A common method for nanoparticle separation, which was introduced in 1976 by Giddings, represents asymmetrical field-flow fractionation (AF4). It is a flow based separation method, which can be theoretically used to separate particles range from 1 nm to 50 µm. However, when the particles are smaller than 10 nm, separation with AF4 will become difficult to perform. Because in this case strong separation force, which induces aggregation of particles, should be applied. This will decrease recoveries of analytes and limit its application in accurate quantitative analysis. Capillary electrophoresis (CE) is another well-developed separation technique, in which samples will be separated in relation to their electrophoretic mobility. In recent years, CE has been used to separate different kinds of nanoparticles like, gold colloids or CdSe Quantum dots. However, till now only separation of particles smaller than 50 nm was reported. Because large size distribution of bigger particles will result in strong peak broadening and long separation time. A two-dimensional coupling of AF4 and CE might provide us a new separation method, which can extend the separation ranges of both methods and be a way to characterise particles with large size distributions. T2 - BAM PhD seminar CY - PhD seminar, Berlin, Germany DA - 22.06.2018 KW - Nanoparticles separation capillary electrophoresis asymmetrcial flow field flow fractionation PY - 2018 AN - OPUS4-47187 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weidner, Steffen T1 - MALDI-MS zur Aufklärung des Mechanismus der homogen katalysierten Polymerisation flüssigkristalliner Seitengruppenmethacrylate T2 - III. BAM-Kolloquium zu "Anwendung von MALDI-MS zur Charakterisierung von synthetischen Polymeren" CY - Berlin, Germany DA - 1999-05-17 PY - 1999 AN - OPUS4-11301 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weidner, Steffen T1 - Erste Untersuchungen zur Infrarot-MALDI-MS von Polymeren T2 - II. BAM-Kolloquium zu "Anwendung von MALDI-MS zur Charakterisierung von synthetischen Polymeren" CY - Berlin, Germany DA - 1998-05-04 PY - 1998 AN - OPUS4-11281 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Copolymer structure elucidation by multidimensional techniques with focus on UPLC x ESI-TOF-MS N2 - Structure elucidation of complex synthetic copolymers still represents a challenge. An one-dimensional separation technique cannot give the answer to the question: What are the molar mass distribution (MMD), the functionality distribution (FTD), the chemical composition distribution (CCD), the monomer sequence distribution (MSD), the topology differences within a single broad distributed polymer sample? Since the first LC/ ESI-MS experiment of the Nobel prize winner John B. Fenn in 1984, the coupling of liquid chromatographic to mass spectrometric techniques gained a continuous rapid development. Often the deficiencies of stand-alone methods can be bridged. LC, blind to structural information needs mass spectrometry as one of the most powerful detectors able to give detailed information on e.g. the repeat units, functionalization or copolymer composition of the chromatographic separated constituents. A separation prior to MS reduces radical the dispersity which is one of the reasons for failing of MS. Also problems with different ionization probabilities in complex mixtures can partly be overcame. Different LC separation techniques as size exclusion chromatography (SEC), liquid adsorption chromatography (LAC), liquid chromatography at critical conditions (LCCC) and gradient elution liquid chromatography (GELC) combined with Matrix assisted Laser Desorption Ionization (MALDI) respectively Electrospray Ionization (ESI) Time of Flight (TOF) mass spectrometry are able to give information which otherwise are completely inaccessible. In some cases CID tandem mass spectrometry is applied. Fragmentation of suitable precursor ions resulted in typical fragment ion patterns. This technique enables an additional information on e.g. sequences, structural defects and topology of complex polymer mixtures. Herein a new approach is demonstrated to provide evidence of different functionalities and short block sequences in statistical EO-PO copolymers. Furthermore silsesquioxane mixtures and Polyglycerols are investigated concerning occurring topology effects. T2 - 253rd ACS National Meeting CY - San Francisco, CA, USA DA - 02.04.2017 KW - Copolymer KW - Microstructure KW - Liquid chromatography KW - Mass spectrometry PY - 2017 AN - OPUS4-43372 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -