TY - CONF A1 - Bäßler, Ralph A1 - Sarmiento Klapper, Helmuth A1 - Feigl, Michael A1 - Hilker, Nico T1 - Suitability of high-alloyed or alternative non-metallic materials in high saline artificial geothermal waters T2 - Corrosion-2014 - XIIth International conference "Problems of corrosion and corrosion protection of structural materials" (Proceedings) N2 - Many technologies have been developed to take advantage of geothermal energy, which became a feasible energy source to replace fossil fliel supply. Nevertheless, Service conditions in geothermal facilities are due to the Chemical composition of hydrothermal fluids and involved high temperatures, in many cases, extreme in terms of corrosion. Therefore, materials selection based on preliminary material qualification is essential to guarantee a secure and reliable Operation ofthe facilities. This contribution deals with the evaluation of the corrosion behavior of two high-alloyed metallic materials and a-A1203 in an artificial geothermal fluid simulating the conditions in the Northern German Basin, a location with high geothermal potential. The suitability of the super austenitic stainless Steel, alloy 31, and the nickel base alloy 59 in this geothermal fluid obtained by electrochemical measurements and exposure tests is addressed. As an alternative to the suitable but costly alloy 59 that showed excelient corrosion resistance against pitting corrosion, ceramic made of a-A1203 represents an interesting possibility for selected components to be used in the construction of geothermal facilities. T2 - Corrosion-2014 - XIIth International conference "Problems of corrosion and corrosion protection of structural materials" CY - Lviv, Ukraine DA - 11.06.2014 KW - Localized corrosion KW - Steel KW - Ni-alloy KW - Ceramic KW - Geothermal energy PY - 2014 SP - 18 EP - 22 AN - OPUS4-32743 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -