TY - CONF A1 - Moufid, M. A1 - Tiebe, Carlo A1 - El Bari, N. A1 - Bartholmai, Matthias A1 - Bouchikhi, B. T1 - Combining of TD-GC-MS and home developed electronic nose for road traffic air monitoring N2 - In this work, we demonstrate the ability of an electronic nose system based on an array of six-semiconductor gas sensors for outdoor air quality monitoring over a day at a traffic road in downtown of Meknes city (Morocco). The response of the sensor array reaches its maximum in the evening of the investigated day which may due to high vehicular traffic or/and human habits resulting in elevated concentrations of pollutants. Dataset treatment by Principal Component Analysis and Discriminant Function Analysis shows a good discrimination between samples collected at different times of the day. Moreover, Support Vector Machines were used and reached a classification success rate of 97.5 %. Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS) technique was used to validate the developed e-nose system by identifying the composition of the analyzed air samples. The discrimination obtained by e-nose system was in good agreement with the TD-GC-MS results. This study demonstrates the usefulness of TD-GC-MS and e-nose, providing high accuracy in discriminating outdoor air samples collected at different times. This demonstrates the potential of using the e-nose as a rapid, easy to use and inexpensive environmental monitoring system. T2 - 2021 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS) CY - Sfax, Tunisia DA - 07.06.2021 KW - GC-MS KW - Electronic nose KW - Gas sensors KW - Urban air monitoring PY - 2021 DO - https://doi.org/10.1109/DTS52014.2021.9498110 SP - 1 EP - 6 AN - OPUS4-54401 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Johann, Sergej A1 - Baensch, Franziska A1 - Sturm, Patrick A1 - Tiebe, Carlo A1 - Pötschke, Samuel A1 - Lay, Vera ED - Holl, H. T1 - HF RFID-based measurement comparison for method optimization in M2 concrete and alkali-activated mortars N2 - Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling. T2 - 37th Danubia - Adria Symposium on Advances in Experimental Mechanics CY - Linz, Austria DA - 21.09.2021 KW - Alkali-activated mortars KW - Passive sensor interface KW - RFID KW - Structural health monitoring KW - Smart structures PY - 2022 DO - https://doi.org/10.1016/j.matpr.2022.03.465 SN - 2214-7853 VL - 62 IS - 5 SP - 2571 EP - 2576 PB - Elsevier CY - Amsterdam AN - OPUS4-54697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sarif, Raduan A1 - Tiebe, Carlo A1 - Herglotz, Christian T1 - Early Response Prediction for H2 Sensors N2 - Green hydrogen (H2) is essential for the global transition to clean energy; it will significantly reduce emissions from heavy industry and the long-distance transport system. H2 can be used as fuel in fuel cells, storing surplus renewable energy, and as a feedstock in industrial processes. However, H2 faces significant safety challenges during storage and transportation. Accidents due to H2 leakage and explosions raise serious concerns due to its high flammability, rapid diffusion in air, and extremely low ignition energy. To mitigate risks associated with H2 leakages, reliable and automated H2 safety systems are essential for emergency repairs or shutdown. An early response from H2 sensors is crucial for early warning in accidents. The earlier response time of H2 sensors is often constrained by their sensor principle, which is heavily influenced by the sensor material’s properties. This study explores methods for earlier sensor response through predictive algorithms. Specifically, we investigate transient response predictions using a First-Order (FO) model and propose improvements through the First-Order with early response and the First-Order with adapted early response model. Both models can predict the stable value of the H2 sensor response from a small time window, which is 70.89% and 83.72% earlier, respectively, than the time required for the sensor hardware to reach it physically. The model’s performance is evaluated by calculating the fitting error with a 2 % threshold. Our current research lays the groundwork for future advancements in real-time sensor response predictions for hydrogen leakage. T2 - IARIA Congress 2025 : The 2025 IARIA Annual Congress on Frontiers in Science, Technology, Services, and Applications CY - Venice, Italy DA - 06.07.2025 KW - H2 Safety KW - H2 leakage detection KW - First-Order (FO) model KW - H2 Sensor data analysis KW - H2 sensor response predictions PY - 2025 AN - OPUS4-64195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Repeatable Testing of a Cryogenic Storage Tank with Variable Insulation Material in Fire Like Conditions N2 - For decarbonizing the energy industry and transport, cryogenic energy carriers have great potential. The storage takes place in tanks with thermal super-insulations, which are in application for decades, but there is only limited knowledge about its behaviour in a fire scenario. This represents a major incident that may generate extraordinary loads on the tank and its insulation system, and that eventually lead to a sudden tank failure. This paper presents a test rig called the Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC), which can be used to test typical thermal superinsulation’s under cryogenic and fire-like conditions in parallel. The test method makes it possible to measure the heat flow through the thermal superinsulation over time and to investigate the degradation behaviour of the insulation within a test. In the paper results from the first tests are presented. T2 - 18th Cryogenics 2025, IIR Conference CY - Prague, Czech Republic DA - 07.04.2025 KW - LH2 KW - LNG KW - Fire KW - Insulation PY - 2025 AN - OPUS4-62979 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Prewitz, M. A1 - Gaber, M. A1 - Müller, Ralf A1 - Marotzke, C. A1 - Holtappels, Kai T1 - Polymer coated glass capillaries and structures for high-pressure hydrogen storage: Permeability and hydrogen tightness N2 - The hydrogen tightness of high-pressure hydrogen storage is a Basic criterion for long-term storage. The H2 permeation coefficients of epoxy resin and a glass lacquer were determined to enable the geometric optimization of a glass capillary storage. It was found that the curing conditions have no significant influence on the H2 permeation coefficient of resin. The H2 permeation coefficient of epoxy resin is only about three orders of Magnitude greater than that of borosilicate glass. This suggests that the initial pressure of 700 bar takes about 2.5 years to be halved in capillary array storage. Therefore, a high-pressure hydrogen storage tank based on glass capillaries is ideally suited for long-term storage in mobile applications. KW - Permeability KW - Glass capillaries KW - Coating KW - Hydrogen storage KW - Long-term calculation KW - Epoxy resin PY - 2018 DO - https://doi.org/10.1016/j.ijhydene.2017.12.092 SN - 0360-3199 VL - 43 IS - 11 SP - 5637 EP - 5644 PB - Elsevier AN - OPUS4-44327 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Holtappels, Kai T1 - Trust in Hydrogen Technologies - Safety Issues in the Hydrogen Value Chain N2 - In June 2020, updated in July 2023, the German government presented the National Hydrogen Strategy (NHS), its first strategy for achieving the goals of its hydrogen policy. The NHS sets out a coherent framework for action for the future production, transportation and use of hydrogen and its derivatives, including the corresponding research, innovations and investments. Various measures have been defined to achieve goals such as the decarbonization of various sectors and the market introduction of hydrogen technologies. This will ultimately lead to the introduction of many “new” technologies in many areas of our daily lives, which will only be successful if decision-makers and the public are convinced that these technologies are safe. Therefore, the safety of hydrogen technologies is an important pillar in gaining and maintaining confidence in these new technologies. Safety must keep pace with, or better still anticipate, trends in technological development in order to avoid overly conservative and expensive s T2 - 10th World Energy Congress (WEC 2024) CY - Singapore DA - 12.11.2024 KW - Hydrogen Safety KW - Trustworthiness KW - Safety research KW - Accidents PY - 2024 AN - OPUS4-62174 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Melzer, Michael A1 - Nattuveettil, Keerthana T1 - Automated generation and utilization of accredited temperature DCCs N2 - The accredited calibration laboratory of the German Federal Institute for Materials Research and Testing (BAM) has established verified XML digital calibration certificates for calibrations of resistance thermometers within the scope of its accreditation. Hence, all necessary information according to ISO/IEC 17025 and the DKD-R 5-1 calibration rule is provided in a machine-readable and machine-interpretable form. For the automated DCC generation, a self-implemented middleware is compiling the metadata (i.e. customer-, order-, item- and method data) and combines it with the measured calibration data and influence conditions into a process- and lab-specific DCC template. This DCC software is able to handle both, single probe calibrations (e.g. Pt 100) as well as measurement chains (e.g. thermometers and temperature loggers) and also supports multiple item calibrations with the automated creation of individual DCC files. All generated DCCs can be readily validated against the DCC scheme (v.3.2.1). The validated and authorized DCCs are equipped with the novel digital accreditation symbol, that was recently piloted with the German national accreditation body (DAkkS), to form `eAttestations´. This advanced electronic seal with a qualified certificate, after successful validation by the receiver, provides three basic functionalities in a DCC: 1. Authenticity: It confirms that the issued certificate actually originates from the BAM calibration laboratory (D-K-11075-08) 2. Integrity: It protects all the data and information in the DCC from change and manipulation 3. Accreditation: It verifies the active accreditation status of the issuing body at the time of sealing (authorization) Thus, this accreditation seal can fully replace an electronic signature on an accredited DCC. In order to demonstrate the added value of DCCs also on the receiver side, the BAM DCC-team started to develop a simple but capable DCC demonstrator. For the use case of thermal process monitoring, the software reads out the metrological data of an incoming DCC, performs a linear regression of the temperature calibration values, uses the obtained calibration function to correct the raw sensor readings, extends the DCC measurement uncertainty values with further contributions (e.g. from the correction and the hysteresis) and adjusts the process-defined acceptance limits to account for the measurement uncertainty, all in real-time. Hence, it automatically utilizes a DCC to obtain metrological traceability and a quality-assured process conformity assessment, practically at the push of a button. In the talk, the automated DCC generation in the scope of our accreditation, including the electronic sealing with the digital accreditation symbol, as well as the one-click DCC utilization with our demonstrator will be presented. The work was performed within the national QI-Digital initiative. T2 - 4th International DCC Conference CY - Online meeting DA - 27.02.2024 KW - Digital Calibration Certificate KW - DCC KW - E-Attestation KW - Calibration KW - Digital Metrology PY - 2024 UR - https://www.dcc-conference-2024.ptb.de/home N1 - Video file from minute 28 on AN - OPUS4-61867 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Theiler, Geraldine A1 - Halder, Karabi A1 - Balasooriya, Winoj T1 - Effect of high-pressure hydrogen environment on the physical and mechanical properties of elastomers N2 - This paper deals with the exposure of HBNR rubbers to high pressure hydrogen (100 MPa) at 120 °C for 7 and 21 days under static conditions followed by characterization of their physical and mechanical properties. T2 - EHEC European Hydrogen Energy Conference 2022 CY - Madrid, Spain DA - 18.05.2022 KW - Rubbers KW - Hydrogen KW - Characterization PY - 2022 SP - 1 EP - 2 AN - OPUS4-62085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Harwege, Finn T1 - Testing of vacuum insulation panels for liquefied hydrogen storage tanks N2 - For the future use of liquefied hydrogen (LH2) as a green energy carrier, new concepts for storage tanks and in particular their insulation are necessary. The methodology applied in current LH2 tanks has some disadvantages while manufacturing and operation of large tanks that may be required in the future. While liquefied natural gas tanks exist in the necessary capacities, they are incompatible with LH2 due to its significantly lower storage temperature. In this paper, the possibility of using vacuum insulation panels (VIPs) as an alternative to the conventional double walled, powder filled vacuum insulation is presented. The two systems are introduced and compared on a conceptual level with a focus on the loss of vacuum failure mode. Furthermore, a test rig that enables the testing and quantification of thermal properties of VIP based insulations in ordinary and loss of vacuum conditions is presented. The test rig is a boil-off calorimeter using liquefied nitrogen and features a square cold surface with a side length of 2 m. An overview over the planned testing and its goals is given. T2 - 18th International Symposium on Loss Prevention and Safety Promotion in the Process Industries CY - Bologna, Italy DA - 08.06.2025 KW - Liquefied Hydrogen KW - LH2 KW - Cryogenics KW - Vacuum KW - Vacuum Insulation Panel PY - 2025 AN - OPUS4-63426 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Gawlitza, Kornelia T1 - Gas standards for the calibration of novel fluorescence sensors for ammonia N2 - Ammonia and its conversion product ammonium have a strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the molar fraction range (0.5 to 500) nmol/mol. There is a need for reliable traceable ammonia gas standards as well as in situ analytical procedures for the monitoring of ammonia in ambient air. The permeation method is an effective tool for dynamically generating precise gas standards with a low uncertainty in the concentration range of a few nmol/mol to several µmol/mol in an inert carrier gas, e. g. pure nitrogen or purified ambient air. Here, we present our ammonia gas standard generator as well as results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. In order to detect ammonia in the nmol/mol-range, a suitable sensor has to be developed. In this contribution, we therefore additionally present first approaches on the development of such a sensor using optical fluorescence as transduction mechanism due to its intrinsically high sensitivity and high spatial resolution. Incorporation of a fluorescent dye, which shows fluorescence enhancement in the presence of ammonia, into a polymer matrix allows to reversibly recognize low amounts of ammonia. It can be concluded that fluorescence sensor is a robust tool for measurements of ammonia; however it needs calibration for the planed use. T2 - MetNH3-workshop on the progress in ammonia metrology CY - Braunschweig, Germany DA - 24.02.2016 KW - Ammonia KW - Fluorescence sensor KW - Permeation KW - Test gas generation PY - 2016 AN - OPUS4-35810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hildebrandt, Jana T1 - Aqueous dispersions of polypropylene: towards referencematerials for nanoplastics characterization N2 - Plastic pollution in the environment is a rising concern for the health of our planet. The plastic litter that pollutes our environment leads to microplastic particles. They can be found (nearly) everywhere. The processes that lead to microplastic can also form nanoplastic particles, which have a size below 1 µm. Because of the small size they can penetrate tissue more easily. Only few risk assessment studies of nanoplastics were carried out so far. Using polystyrene (PS) nanoparticles to test effects on organisms is easy because it is commercially available. However, this falls a little short, as the polyolefins i.e., polypropylene (PP) and polyethylene (PE), are produced in a larger proportion than PS. Moreover, these plastics are mainly used for disposable products, which means that they also account for a large proportion of plastic waste. Therefore, the percentage of polyolefins in environmental nanoplastic is presumably high. It is important to test the toxicological effects also with nanoplastics made of PP and PE to have more realistic results. Herein, we present an easy and repeatable method to prepare an aqueous dispersion of polypropylene nanoplastics (nano-PP). They are stabilized electrostatically, resulting in a strongly negative zeta potential of -43 mV (± 2 mV) and making no surfactant necessary to keep the dispersion stable. The size and the size distribution were determined via Dynamic Light Scattering (DLS) and gives a hydrodynamic diameter of 180.5 nm (± 5.8 nm) and a PDI of 0.084 (± 0.023). Finally, ca. 480 bottles of the dispersion with a volume of 10 mL each were prepared to serve as a potential reference material for further testing of detection methods or risk assessments. T2 - International Conference on Microplastic Pollution in the Mediterranean Sea CY - Neapel, Italy DA - 25.09.2022 KW - Nanoplastic PY - 2022 AN - OPUS4-55963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thünemann, Andreas T1 - Characterization of (bio)macromolecules and polymeric materials with modern scattering methods N2 - The analysis of polymers, biopolymers and polymeric materials is of great interest in biomaterials science. Here small-angle x-ray scattering (SAXS), static light scatterin (SLS) and dynamic light scattering (DLS) are described. Current efforts for digitalization of this methods are explaind with respect to modern data science in biomedical research. T2 - MacroBio Summer School 2018: Biomaterial Science in View of Digitalization CY - Teltow, Germany DA - 24.09.2018 KW - Small-angle x-ray scattering KW - SAXS KW - Static light scattering KW - SLS KW - Dynamic light scattering KW - DLS KW - Biomaterials PY - 2018 AN - OPUS4-46051 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Böttcher, Nils T1 - Nominal and Off-Nominal Battery / High Energy Storage Testing Off-Nominal cell and battery testing at BAM N2 - The abuse testing of electrochemical energy storage systems poses a major safety challenge. Thanks to its core competence in ensuring safety in technology and chemistry, BAM has the capabilities to carry out safety tests from small to large scale. Tests up to approx. 200Wh (lithium-ion batteries) can be carried out in the cell test center and abuse tests up to 20kWh are possible in the open field test on the TTS. T2 - Europe Energy Storage Safety Summit CY - Petten, Netherlands DA - 08.10.2024 KW - Battery Safety KW - Abuse testing KW - Lithium-ion batteries KW - Safety critical tests PY - 2024 AN - OPUS4-62321 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fuhrmann, A. T1 - Conditional repair by locally switching the thermal healing ability of dynamic covalent polymers ON and OFF with light N2 - Healable materials are able to repair inflicted damages, herin often applied: dynamic covalent polymer networks. We have shown in this study that light of different colors shift the Diels-Alder and retro Diels-Alder crosslinking and decrosslinking equilibrium. This effect was utilized for self-healing of a polymer film. Small-angle X-ray scattering was used to quantifiy the polymeric mesh size on a nanoscale. T2 - Polydays 2016 CY - Potsdam, Germany DA - 28.09.2016 KW - Polymer KW - Small-angle X-ray scattering KW - SAXS KW - Self-healing PY - 2016 AN - OPUS4-37570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -