TY - CONF A1 - Scheidemann, Robert A1 - Kasparek, Eva Maria A1 - Müller, Karsten A1 - Droste, Bernhard A1 - Völzke, Holger T1 - Model-sized and full-scale dynamic penetration tests on damping concrete N2 - Mechanical loading conditions of transport and storage casks for radioactive materials in accidental scenarios are highly affected by the behavior of both: the impact limiters and the footing materials. To minimize potential damages during the handling of casks, a so called damping concrete is frequently used for the footings in interim nuclear facilities. It obtains its shock absorbing properties through admixing of polymer cells. For a comprehensive mechanical evaluation of casks, advanced material models are also needed for damping concrete. In order to characterize the mechanical properties and to develop numerical material models, penetration tests were carried out at different test facilities of BAM. The tests contain static and dynamic penetration tests on cubic specimen with an edge length of 100 mm as well as mortared specimen with a size of 240 x 240 x 50 cm³. Indenters with different geometries and diameters were used for these model-sized penetration tests. Subsequently a full-scale cylindrical cast-iron indenter with a diameter of 110 cm was dropped of 5 m height on a realistic damping concrete footing. T2 - PATRAM 2013 - 17th International symposium on the packaging and transportation of radioactive materials CY - San Francisco, CA, USA DA - 18.08.2013 KW - Drop test KW - Dynamic KW - Penetration KW - Damping concrete PY - 2013 SP - 1 EP - 10 PB - Omnipress AN - OPUS4-30233 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zencker, Uwe A1 - Qiao, Linan A1 - Völzke, Holger T1 - Influence of impact angle and real target properties on drop test results of cubic containers N2 - Drop test scenarios with cubic containers without impact limiters at interim storage sites or in a final repository have been investigated by numerical simulations. An ideally flat drop is impossible to conduct as a free fall of a container even under laboratory conditions. Dynamic stresses and strains inside the container structure are sensitive to the impact angle. Even very small impact angles cause remarkable changes in the experimental or numerical results when a flat bottom or wall of a container hits a flat target. For drop tests with transport packages the International Atomic Energy Agency (IAEA) regulations define an essentially unyielding target. In contrast, potential accident scenarios for storage containers are derived from site-specific safety analyses or acceptance criteria in Germany. Each interim storage site or repository has a yielding or so-called real target with individual structural and material properties. The real target acts as a kind of impact limiter. A more conservative container design is required if the impact limiting effect of the target is not considered. T2 - ASME 2017 Pressure Vessels and Piping Conference CY - Waikoloa, Hawaii, USA DA - 16.07.2017 KW - Finite element method KW - Simulation KW - Drop test KW - Impact angle KW - Real target KW - Yielding target PY - 2017 SN - 978-0-7918-5802-8 DO - https://doi.org/10.1115/PVP2017-65731 VL - 7 SP - Article UNSP V007T07A039, 1 EP - 9 AN - OPUS4-43631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Auersch, Lutz T1 - Impacts Between Different Drop Masses and Different Targets in Different Scales N2 - The Federal Institute of Material Research and Testing has performed many impact tests from very small laboratory tests to very big “free-field” tests with heavy containers on stiff foundations. The first measurements have been done on a big foundation where it should be guaranteed that the foundation is rigid and the container is tested properly. Later on, a smaller drop test facility has been built on the ground inside an existing building. It had to be controlled by prediction and measurements that the drop test will not damage the building. Tests from different heights on soft, medium, and stiff targets have been done to find out rules which allow to identify acceptable and unacceptable drop tests. Later on, the biggest drop test facility has been built for masses up to 200 t. It was necessary for the design of the foundation to estimate the forces which oc-cur during the drop tests. In addititon, the acceptable tests should be selected and controlled by measurements where the impact duration is important. Dif-ferent sensors, accelerometers, accelerometers with mechanical filters, geo-phones (velocity transducers), strain gauges, and pressure cells have been ap-plied for these tasks. Signal transformations and model calculations have been used to check and understand the dynamic measurements. The simplest law is the conservation of the momentum which is a good approximation if the impact is short. If the soil under the foundation has an influence on the deceleration of the container, the maximum foundation velocity is lower than the simple esti-mation. T2 - Experimental Vibration Analysis for Civil Engineering Structures (EVACES 2023) CY - Milano, Italy DA - 30.08.2023 KW - Drop test KW - Vibration measurements KW - Container loading KW - Foundation load PY - 2023 SN - 978-3-031-39116-3 DO - https://doi.org/10.1007/978-3-031-39117-0_60 SN - 2366-2557 SP - 592 EP - 602 PB - Springer Nature Switzerland CY - Cham, Schweiz AN - OPUS4-58503 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -