TY - JOUR A1 - Becker, Roland A1 - Scholz, Philipp A1 - Jung, Christian A1 - Weidner, Steffen T1 - Thermo-Desorption Gas Chromatography-Mass Spectrometry for investigating the thermal degradation of polyurethanes JF - Analytical Methods N2 - Thermo-Desorption Gas Chromatography-Mass Spectrometry (TD-GC-MS) was used to investigate the thermal degradation of two different polyurethanes (PU). PU samples were heated at different heating rates and the desorbed products were collected in a cold injection system and thereafter submitted to GC-MS. Prospects and limitations of the detection and quantification of semi-volatile degradation products were investigated. A temperature dependent PU depolymerization was found at temperatures above 200 °C proved by an increasing release of 1,4-butanediol and methylene diphenyl diisocyanate (MDI) representing the main building blocks of both polymers. Their release was monitored quantitatively based on external calibration with authentic compounds. Size Exclusion Chromatography (SEC) of the residues obtained after thermodesorption confirmed the initial competitive degradation mechanism indicating an equilibrium of crosslinking and depolymerization as previously suggested. Matrix-Assisted Laser Desorption Ionization (MALDI) mass spectrometry of SEC fractions of thermally degraded PUs provided additional hints on degradation mechanism. KW - Thermo-desorption KW - Mass spectrometry KW - Polyurethanes KW - Thermal degradation PY - 2023 DO - https://doi.org/10.1039/D3AY00173C SN - 1759-9660 SP - 1 EP - 6 PB - Royal Society for Chemistry AN - OPUS4-57307 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lörchner, Dominique A1 - Tang, Ductri A1 - Mauch, Tatjana A1 - Jung, Christian A1 - Hofmann, Andrea A1 - Kroh, L.W. T1 - Development and validation of a liquid chromatography-mass spectrometry method for simultaneous analysis of triazine-based brominated flame retardants in environmental samples JF - Analytical and Bioanalytical Chemistry N2 - In the present study, a novel and reliable analytical method was developed and validated for the simultaneous determination of 1,3,5-tris(2,3-dibromopropyl)-1,3,5-triazine-2,4,6(1H,3H,5H)-trione (TDBP-TAZTO) and 2,4,6-tris(2,4,6-tribromophenoxy)-1,3,5-triazine (TTBP-TAZ) in environmental samples using high-performance liquid chromatography coupled to a tandem mass spectrometer. Firstly, for optimization of the liquid chromatography separation, mobile phases, oven temperatures, modifiers, and buffers were varied. Afterwards, the extraction efficiency of sediment and fish samples was tested with different techniques (pressurized liquid, solid-liquid, ultrasound-assisted, and Soxhlet extraction). Additionally, cleanup using modified multilayer silica gel (sediment) and gel permeation chromatography as well as Florisil® columns (fish) with several solvent mixtures were performed. The best results were obtained with the pressurized liquid extraction (optimal conditions: extraction solvent 100% toluene, extraction time 20 min, cycles two, extraction temperature 100 °C, and flushing volume 60%) compared to other solvent extraction methods. On the basis of this optimized analytical procedure, the method was validated with satisfactory values of correlation coefficient (R2) between 0.998 and 0.999 for both matrices in the calibration range of 2.0–502.0 μg kg−1 for TDBP-TAZTO and 16.6–770.6 μg kg−1 for TTBP-TAZ in sediment samples as well as 4.8–303.5 μg kg−1 and 47.4–742.5 μg kg−1 in fish samples (bream), respectively.Mean recoveries (n=5) were calculated for both analytes with spiked matrices at one concentration level (100 μg kg−1) between 98 and 114% with intra-day relative standard deviations less than 11%. The inter-day precision (n = 15) was also acceptable for both compounds < 11%. It was found that the limit of detection and limit of quantification were in the range of 0.4–1.3 μg kg−1 for TDBP-TAZTO and 10–28 μg kg−1 for TTBP-TAZ in surface sediment samples and 7–25 μg kg−1 and 22–80 μg kg−1 in fish samples (bream), respectively. The results indicated that these analytical methods could provide reliable and efficient approaches for quantification of TDBP-TAZTO and TTBPTAZ in sediment and fish samples. KW - Brominated flame retardants KW - Pressurized liquid extraction KW - TDBP-TAZTO KW - TTBP-TAZ KW - Sediment and fish samples PY - 2020 DO - https://doi.org/10.1007/s00216-020-03057-x VL - 413 IS - 4 SP - 987 EP - 998 PB - Springer AN - OPUS4-51685 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Piechotta, Christian A1 - Iznaguen, Hassan A1 - Traub, Heike A1 - Feldmann, Ines A1 - Köppen, Robert A1 - Witt, Angelika A1 - Jung, Christian A1 - Becker, Roland A1 - Oleszak, Katrin A1 - Bücker, Michael A1 - Urban, Klaus A1 - Reger, Christian A1 - Ostermann, Markus T1 - Bewitterungsszenarien im Vergleich – Veränderungen in der Oberflächenmorphologie von Polypropylen (PP) und Polystyrol (PS) unter dem Aspekt des Austrags von polybromierten Flammschutzmitteln T2 - Umwelteinflüsse erfassen, simulieren, bewerten N2 - Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden. T2 - 47. Jahrestagung der GUS CY - Blankenloch-Stutensee, Germany DA - 21.03.2018 KW - Schadstoffaustrag KW - Umweltsimulation KW - Bewitterung PY - 2018 SN - 978-981-18507-2-7 VL - 47 SP - 115 EP - 128 AN - OPUS4-49802 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schallschmidt, Kristin A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Nehls, Irene A1 - Leschber, G. A1 - Frese, S. A1 - Walles, T. A1 - Neudecker, J. T1 - Comparison of volatile organic compounds from lung cancer patients and healthy controls—challenges and limitations of an observational study JF - Journal of Breath Research N2 - The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates. KW - Breath KW - Volatile organic compounds KW - Marker KW - Cancer KW - Gas chromatography KW - Solid phase microextraction KW - Volatilome PY - 2016 DO - https://doi.org/10.1088/1752-7155/10/4/046007 SN - 1752-7155 SN - 1752-7163 VL - 10 IS - 4 SP - Article 046007, 1 EP - 17 PB - IOP Publishing AN - OPUS4-37801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schallschmidt, Kristin A1 - Becker, Roland A1 - Jung, Christian A1 - Rolff, J. A1 - Fichtner, I. T1 - Investigation of cell culture volatilomes using solid phase micro extraction: options and pitfalls exemplified with adenocarcinoma cell lines JF - Journal of chromatography B N2 - Three strategies to sample volatile organic compounds (VOC) from lung cancer cell lines cultured in vitro were compared. Headspace solid phase microextraction was applied in situ to culture flasks and alternatively to subsamples of headspace gas or to nutrient solution subsamples followed by gas chromatography–mass spectrometry. The direct quantification of 55 VOC in the headspace of cell cultures was validated and is discussed with respect to reproducibility and system-related interferences. The role of the VOC background from culture media and usually employed polystyrene culture vessels is examined and was seen to invoke potentially misleading conclusions. The commercial A549 and two further adenocarcinoma cell lines displayed largely similar VOC profiles with distinct differences regarding certain individual substances. There is evidence for the inappropriateness of the standard cell culturing methods in the search for volatile cancer markers. KW - A549 KW - Lung cancer cell culture KW - GC–MS KW - SPME KW - VOC KW - Volatilome KW - Alcohol marker KW - Micropulverization KW - HPLC-MS/MS KW - Fortification KW - Long term stability PY - 2015 DO - https://doi.org/10.1016/j.jchromb.2015.10.004 SN - 0378-4347 SN - 1570-0232 SN - 1387-2273 SN - 1873-376X VL - 1006 SP - 158 EP - 166 PB - Elsevier B.V. CY - Amsterdam [u.a.] AN - OPUS4-34991 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Becker, Roland A1 - Jung, Christian A1 - Nehls, Irene T1 - The homogeneity testing of EtG in hair reference materials: A high-throughput procedure using GC-NCI-MS JF - Forensic science international N2 - The validation of a robust quantification procedure for EtG in hair using GC–NCI–MS is presented. Aqueous extraction is followed by complete lyophylization of the extract and derivatization with pentafluoropropionic anhydride (PFPA) under controlled temperature and duration. Clean-up of extracts was dispensable and standard single quadrupole MS displayed sufficient selectivity and sensitivity. The method displayed a wide linearity range and enabled LOD of 0.68 pg/mg, LOQ of 2.4 pg/mg, and precision below 8.12%. Since EtG was seen to display prolonged stability in the aqueous extracts and after derivatization with PFPA this straightforward procedure allows a routine throughput of large quantities of samples with little proneness to procedural scatter of results. The method was applied to demonstrate the homogeneity of two hair reference materials with mean EtG contents of 8.48 pg/mg and 22.0 pg/mg. Aside from the application in homogeneity studies of hair reference materials predominantly in the concentration range of 10–50 pg/mg the method was also designed for daily routine quantification of real-world sample with regard to drinking behavior assessment. KW - Extraction KW - Derivatization KW - High-throughput analysis KW - Reference materials KW - Homogeneity KW - Measurement uncertainty PY - 2013 DO - https://doi.org/10.1016/j.forsciint.2013.01.018 SN - 0379-0738 SN - 1872-6283 VL - 226 IS - 1-3 SP - 202 EP - 207 PB - Elsevier Ltd. CY - Amsterdam [u.a.] AN - OPUS4-27998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Jung, Christian A1 - Schröter-Kermani, C. A1 - Bremser, Wolfram A1 - Nehls, Irene T1 - Temporal trend (1988-2008) of hexabromocyclododecane enantiomers in herring gull eggs from the german coastal region JF - Chemosphere N2 - Levels of α-, β-, and γ-hexabromocyclododecane (HBCD) were determined in pooled eggs from herring gulls (Larus argentatus) sampled on three bird sanctuaries near the German North Sea coast between 1988 and 2008 (Mellum and Trischen) and the German Baltic Sea coast between 1998 and 2008 (Heuwiese) and archived by the German Environmental Specimen Bank. Pressurized fluid extraction, gel permeation chromatography, and LC–MS/MS using 13C12-labelled isotope standards and a chiral column were applied. α-HBCD was the dominating diastereomer and ranged between 3.7 and 107 ng g-1 lw while β- and γ-HBCD were throughout close to LOQ. The highest α-HBCD concentration was found in eggs from Mellum sampled in the year 2000. Interestingly, HBCD in eggs from the three islands displayed similar time courses with levels increasing to a peak contamination around 2000 and decreasing levels ever since. Chiral signatures of α-HBCD in eggs differed among the islands but indicated a preferential enrichment of the first eluting enantiomer (-)-α-HBCD. KW - Brominated flame retardant KW - Chiral separation KW - HPLC-ESI-MS/MS KW - Enantiomer-specific bioaccumulation PY - 2011 DO - https://doi.org/10.1016/j.chemosphere.2010.12.047 SN - 0045-6535 SN - 0366-7111 VL - 83 IS - 2 SP - 161 EP - 167 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-23351 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -