TY - CONF A1 - Altmann, Korinna T1 - Microplastics at BAM: TED-GC/MS and reference materials N2 - Thsi talk aims to present the activities of microplastic analysis at BAM according to TED-GC/MS and reference materials developement. T2 - Webinar BAM / University of Birmingham CY - Online meeting DA - 15.06.2021 KW - Microplastic KW - TED-GC/MS KW - Reference materials PY - 2021 AN - OPUS4-53738 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Fast quantitative detection of microplastics using TED-GC/MS, an innovative thermoanalytical method N2 - Im Vortrag wird die BAM vorgestellt und die Motivation für Engagement im Feld der Mikroplastikanalysen dargelegt. Die Herausforderungen bei der Analyse werden aufgezeigt und der Umgang mit ihnen. Das Arbeitsprinzip der TED-GC/MS sowie Leistungsparameter werden erläutert sowie das Vorgehen zur Identifikation und Quantifizierung von Polymeren in er Umwelt. An ausgewählten Beispielen werden interessante Ergebnisse präsentiert und die Mikroplastikreferenzmaterialien der BAM vorgestellt. N2 - In the talk, the BAM is introduced and the motivation for our engagement in the field of microplastic analysis is explained. The challenges in the analysis of microplastics are shown and how we deal with them. The working principle of TED-GC/MS and its performance parameters are presented, as well as the procedure for identifying and quantifying polymers in environmental samples. Interesting results are shown using selected examples. Finally, BAM's microplastic reference materials are highlighted. T2 - National Environmental Monitoring Conference CY - Online meeting DA - 02.08.2021 KW - Microplastic KW - TED-GC/MS KW - Environmental analysis PY - 2021 AN - OPUS4-53081 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik – Ein Problem für die Menschheit? N2 - Mikroplastik findet sich in Ozeanen, Seen, Flüssen und Bächen. Es kann in unserem Boden, in der Luft und sogar in Organismen nachgewiesen werden. Jedes Jahr werden weltweit Millionen Tonnen freigesetzt. Doch wo und wie landet Mikroplastik in der Umwelt? Und wie können wir diese winzigen Partikel nachweisen? T2 - Berlin Science Week CY - Berlin, Germany DA - 01.11.2021 KW - Mikroplastik KW - TED-GC/MS PY - 2021 AN - OPUS4-53734 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna A1 - Braun, U. T1 - Monitoring von Mikroplastik N2 - Der Vortrag gibt einen Überblick was bei der Analyse von Mikroplastik zu beachten ist und beschreibt die Vor- und Nachteile der TED-GC/MS. T2 - Abschlusstreffen MikroPlaTas CY - Online meeting DA - 23.06.2021 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik PY - 2021 AN - OPUS4-52916 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - DACHS/MOFs/AutoMOFs_2/Synthesis N2 - The DACHS (Database for Automation, Characterization and Holistic Synthesis) project aims to create completely traceable experimental data, covering syntheses, measurements, analyses, and interpretations. DACHS_MOFs focuses on the synthesis and characterisation of metal-organic frameworks, across multiple, automation-assisted experimental series (AutoMOFs), with the overall goal of producing reproducible MOF samples through tracking of the synthesis parameters. DACHS_MOFs is simultaneously used to test the DACHS principles. This upload contain synthesis data from AutoMOFs_2 in HDF5 format (.h5). Each .h5 file contains detailed information on the chemical, experimenal, and synthesis parameters used during the synthesis of a single AutoMOF sample. KW - Automation KW - Procedure KW - Synthesis KW - Traceability PY - 2024 DO - https://doi.org/10.5281/zenodo.11236074 PB - Zenodo CY - Geneva AN - OPUS4-60611 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - DACHS/MOFs/AutoMOFs_1/Synthesis N2 - The DACHS (Database for Automation, Characterization and Holistic Synthesis) project aims to create completely traceable experimental data, covering syntheses, measurements, analyses, and interpretations. DACHS_MOFs focuses on the synthesis and characterisation of metal-organic frameworks, across multiple, automation-assisted experimental series (AutoMOFs), with the overall goal of producing reproducible MOF samples through tracking of the synthesis parameters. DACHS_MOFs is simultaneously used to test the DACHS principles. This upload contain synthesis data from AutoMOFs_1 in HDF5 format (.h5). Each .h5 file contains detailed information on the chemical, experimenal, and synthesis parameters used during the synthesis of a single AutoMOF sample. KW - Synthesis KW - Automation KW - Traceability KW - Procedure PY - 2024 DO - https://doi.org/10.5281/zenodo.11236031 PB - Zenodo CY - Geneva AN - OPUS4-60243 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob A1 - Moeez, A. A1 - Hörmann, Anja A1 - Breßler, Ingo T1 - Example configurations and test cases for the Python HDF5Translator framework. N2 - This is a set of use examples for the HDF5Translator framework. This framework lets you translate measurement files into a different (e.g. NeXus-compatible) structure, with some optional checks and conversions on the way. For an in-depth look at what it does, there is a blog post here. The use examples provided herein are each accompanied by the measurement data necessary to test and replicate the conversion. The README.md files in each example show the steps necessary to do the conversion for each. We encourage those who have used or adapted one or more of these exampes to create their own conversion, to get in touch with us so we may add your example to the set. KW - Measurement data conversion KW - Data conversion KW - HDF5 KW - NeXus KW - NXsas KW - Framework KW - Python PY - 2024 DO - https://doi.org/10.5281/zenodo.10925971 PB - Zenodo CY - Geneva AN - OPUS4-59796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falqueto, J. B. A1 - Clark, A. H. A1 - Štefančič, A. A1 - Smales, Glen Jacob A1 - Vaz, C. A. F. A1 - Schuler, A. J. A1 - Bocchi, N. A1 - Kazzi, M. E. T1 - High performance doped Li-rich Li1+xMn2–xO4 cathodes nanoparticles synthesized by facile, fast, and efficient microwave-assisted hydrothermal route N2 - Li-rich nanoparticles of Li1+xMn2–xO4 doped with Al, Co, or Ni are successfully synthesized using a facile, fast, and efficient microwave-assisted hydrothermal route. Synchrotron X-ray diffraction confirms the formation of the crystalline cubic spinel phase type. X-ray absorption spectroscopy analysis at the Co and Ni K- and L-edges verifies that the dopants are within the Li1+xMn2–xO4 spinel structure and are inactive during cycling in the bulk and at the surface. Moreover, we demonstrate that nanocrystallinity and cationic doping play an important role in improving the electrochemical performance with respect to LiMn2O4 microparticles. They significantly reduce the charge-transfer resistance, lower the first cycle irreversible capacity loss to 6%, and achieve a capacity retention between 85 and 90% after 380 cycles, with excellent Coulombic efficiency close to 99% without compromising the specific charge at a 5C cycling rate. Furthermore, the Mn K- and L-edges attest that after long cycling, the Mn oxidation state in the bulk differs from that at the surface caused by the Mn disproportion reaction; however, the cationic doping helps mitigate the Mn dissolution with respect to the undoped Li1+xMn2–xO4 nanoparticles, as indicated by inductively coupled plasma atomic emission spectrometry. KW - XAS KW - SAXS KW - Li-ion battery KW - Cathode material KW - Spinel KW - The MOUSE PY - 2022 DO - https://doi.org/10.1021/acsaem.2c00902 SN - 2574-0962 VL - 5 IS - 7 SP - 8357 EP - 8370 PB - ACS Publ. CY - Washington, DC AN - OPUS4-55359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - X-ray scattering for nanostructure quantification, and the quest for the perfect experiment N2 - Measuring an X-ray scattering pattern is relatively easy, but measuring a steady stream of high-quality, useful patterns requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). With the MOUSE, we have combined a comprehensive and highly automated laboratory workflow with a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. This talk will briefly introduce the foundations of X-ray scattering, present the MOUSE project, and will highlight the proven utility of the methodology for materials science. Upgrades to the methodology will also be discussed, as well as possible avenues for transferring this holistic methodology to other instruments T2 - SNI 2022 CY - Berlin, Germany DA - 05.09.2022 KW - Methodology KW - X-ray scattering KW - Laboratory management KW - Instrumentation utilization KW - MOUSE KW - SAXS KW - WAXS KW - Automation PY - 2022 AN - OPUS4-55760 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - PE-Rezyklat Einsatz in Gefahrgutbehältern? N2 - In diesem Vortrag geht es darum zu beschreiben, ob Rezyklat für PE Behälter gefüllt mit Gefahrgut Anwendung finden darf. Kanister aus Neuware und Rezyklat wurden verschiedenen Untersuchungen unterzogen. Es wurde der Feststoff und Leachable getestet. Methoden sind TED-GC/MS und GC-HRMS. Proben der Leachable wurden nach 1 und 4 Wochen genommen und die Peakanzahl vergleichen dargestellt. Als Lösemittel wurden Wasser, Ethanol, EtOAc, Ammoniak und HNO3 verwendet. T2 - Fachaustausch Projekt GeSKAR CY - Dessau, Germany DA - 10.01.2025 KW - Gefahrgutbehälter KW - Rezyklat PY - 2025 AN - OPUS4-62396 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Textile Fibers as Reference Materials for Microplastic Release N2 - Fibers of textile origin are named as high contributor for microplastic pollution in the environment next to e.g. plastics from packaging, tire wear and paints. Small fibers and fragments (microplastics: 1-1000 µm) can be released from textiles by mechanical abrasion during application (e.g. wearing) or washing. To date, the occurrence, transport pathways, and impacts of such small fibers on the environment and human health remain unclear. The European Commission revised the Urban Wastewater Treatment Directive (Directive (EU) 2024/3019) and made monitoring of microplastics mandatory in the next years. Additionally, standards for microplastic detection are developed in the ISO standardization body ISO/TC 147/SC 2 with the documents ISO/DIS 16094-2 and ISO/DIS 16094-3. Detection mainly occurs by thermoanalytical methods for mass or vibrational methods with microscopes for numbers. Such standards and regulatory efforts need validated methods, which themselves need reference materials for validation. Reference materials are well characterized materials that are produced for a specific purpose and are homogeneous and stable within one property of interest. The shape and the composition of the reference particles/fibers will affect the detection, hence it is important to validate the instruments with fibers, if this is the task for monitoring campaigns. This work describes the production of realistic fibers as reference material for microplastic analysis. The individual samples contain of a small number (< 1000) and mass (< 20 µm) of fibres. Homogeneity and stability control occurred by thermogravimetric analysis and µ-Raman. Further characteristics were determined for type, shape and size distribution. T2 - TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Reference materials KW - Microfibers KW - Microfiber release PY - 2025 AN - OPUS4-64620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - PlasticTrace WP1 – Stakeholder Workshop N2 - The talk summarizes the achievments of WP1 of the PlasticTrace project. Microplastic reference materials were developed by producing tablets. Different preparation methods were compared. Characterisation of the tablets was done after filtration with µFTIR, QCL, µRaman, Py-GC/MS and TED-GC/MS after ISO standards ISO 16094-2 and ISO/FDIS 16094-3. Polymer types are polypropylene and polyethylene terephthalate. T2 - Stakeholder Workshop PlasticsTrace CY - Online meeting DA - 09.09.2025 KW - Microplastics KW - Reference materials KW - TED-GC/MS KW - PET PY - 2025 AN - OPUS4-64258 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Putzu, Mara A1 - Barbaresi, Marta A1 - Fadda, Marta A1 - Sacco, Alessio A1 - Piergiovanni, Maurizio A1 - Masino, Matteo A1 - Bianchi, Federica A1 - Altmann, Korinna A1 - Benismail, Nizar A1 - Coïc, Laureen A1 - Fenoglio, Ivana A1 - Mattarozzi, Monica A1 - Rossi, Andrea Mario A1 - Careri, Maria A1 - Giovannozzi, Andrea Mario T1 - Accuracy assessment of a micro-Raman spectroscopy method for small microplastic particles in infant milk formula N2 - The presence of microplastics (MPs) in the food chain is increasingly documented, raising concerns over potential risks to human health. Despite growing efforts, standardized methods for MPs detection in food matrices remain limited. This study presents an interlaboratory comparison (ILC) aimed at assessing the accuracy and comparability of an analytical approach for the identification and quantification of small MPs (5–100 μm) in infant milk powder using μ-Raman spectroscopy and a representative polyethylene terephthalate (PET) reference material (RM). The RM, formulated as water-soluble tablets, was designed to replicate the morphology, size distribution, and polymer composition of environmentally relevant MPs, and was previously assessed for homogeneity and stability for mass fraction and particle numbers. The approach was assessed using two PET RM batches with different MPs particle numbers (high load batch: 1759 ± 141 MPs; low load batch: 160 ± 22 MPs), subjected to an enzymatic–chemical digestion, followed by μ-Raman analysis performed independently in two laboratories with different instruments and operators. Results are reported as absolute particle counts per analyzed sample and demonstrated excellent recovery across all size classes, including the smallest particles (down to 5 μm), with recovery rates ranging from 82 % to 88 %, in good agreement with the RM reference values. The analytical approach proved to be robust, reproducible, and suitable for low-level MPs quantification in complex food matrices, supporting ongoing efforts toward method harmonization and standardization for reliable MPs monitoring in the food sector. KW - Microplastics KW - Milk KW - Raman microspectroscopy PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646239 DO - https://doi.org/10.1016/j.talo.2025.100586 SN - 2666-8319 VL - 12 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-64623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dinter, Adelina-Elisa T1 - Development of a single cell-ICP-ToF-MS-method for multielement analysis of MIC organisms grown on solid steel samples N2 - The latest ICP-MS technology - ICP-ToF (time of flight)-MS – enables the analysis of the multi-element fingerprint of individual cells. The interface between material and environmental analysis thus receives special attention, e.g., when considering corrosion processes. Microbiologically influenced corrosion (MIC) is a highly unpredictable phenomenon due to the influence of the environment, microbial communities involved and the respective electron source. However, the interaction pathway between cells and the metal surface remains unclear. The development of the MIC-specific ICP-ToF-MS analytical method presented here at the single cell level, in combination with the investigation of steel-MIC interactions, contributes significantly to progress in instrumental MIC analysis and will enable clarification of the processes taking place. For this, a MIC-specific staining procedure was developed. It allows the analysis of archaea at a single cell level and provides information about the interaction of the cells with the staining agent which is extremely scarce compared to other well characterized organisms. Additionally, the single cell ICP-ToF-MS is used for the analysis of archaea involved in MIC of steel. Hence, the possible uptake of individual elements from different steel samples is investigated - the information obtained will be used in the future to elucidate underlying mechanisms and develop possible material protection concepts, thus combining modern methods of analytical sciences with materials. T2 - DAAS Doktorandenseminar 2021 CY - Online meeting DA - 20.09.2021 KW - Sc-ICP-ToF-MS KW - Single cell analysis KW - Microbiologically influenced corrosion KW - Archaea PY - 2021 AN - OPUS4-53340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Wessen Problem ist Mikroplastik eigentlich? N2 - In den letzten 20 Jahren ist die Aufmerksamkeit vieler Forschender sowie der Politik und der Bürger selbst auf ein wachsendes Kunststoffproblem unserer Zeit stark gestiegen. Mangelnde Wertstoffkonzepte, Sammelstellen und unbedachtes Einbringen von Kunststoffprodukten in die Umwelt führen dort zu einer Anreicherung. Durch äußere Witterungseinflüsse können diese Produkte degradieren und fraktionieren, so dass heute in allen Teilen der Welt Mikroplastik (1-1000 µm, ISO/TR 21960:2020) unterschiedlicher Polymermaterialien nachgewiesen werden kann. Bei Mikroplastik gilt das Vorsorgeprinzip. Die Partikel können weiter zerfallen in Nanoplastik (< 1 µm, ISO/TR 21960:2020). Ob eine toxikologische Gefährdung von Mikro- oder Nanoplastik ausgeht, wird vielfältig untersucht. Bisher stehen valide Ergebnisse aus. Untersuchungen zur Häufigkeit, dem Transport und möglicher Senken und Eintragspfade muss aber Rechenschafft getragen werden, so dass ein Monitoring von Mikroplastik bereits in der Revision der Trinkwasserrahmen-Richtlinie und der Abwasserrahmen-Richtlinie gefordert wird. Bedenklich ist auch die Verordnung über Mindestanforderungen an die Wasserwiederverwendung (2020/741), in welcher nicht verbindlich gesagt wird, Wasser welcher Reinigungsstufe eines Klärwerks auf die Felder zur Wiederverwendung aufgebracht werden darf. Einer Regulierung über die EU-Plastikstrategie hinaus mit z.B. Verboten für Einwegplastik-Produkte und Rezyklingquoten kann nur entgegengewirkt werden, wenn valide Messmethoden, Referenzmaterialien und Standards existieren, die das tatsächliche Ausmaß von Mikroplastik-Konzentrationen in Luft, Wasser, Boden und Biota zuverlässig und genau aufzeigen. T2 - Technomer CY - Chemnitz, Germany DA - 06.11.2025 KW - Mikroplastik KW - Referenzmaterial KW - TED-GC/MS PY - 2025 AN - OPUS4-64618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Alasonati, E A1 - Bartczak, D A1 - Altmann, Korinna A1 - Giovannozzi, A T1 - Towards Standardised Micro and Nanoplastics Analysis via Interlaboratory Comparisons: First Outlook of the VAMAS TWA 45 P3 Project N2 - This talk is part of the stakeholder workshop of the PlasticTrace project held in September 2025 in Oslo. The presentation shows first results of the VAMAS ILC on nanoplastics. PP nanoparticles were given to the participants. These were asked to measure the mass or particle number or size of the PP nanoplastics. Various techniques such as DLS, FFF, Py-GC/MS, TED-GC/MS, PTA were used. T2 - Stakeholder Workshop PlasticsTrace CY - Online meeting DA - 09.09.2025 KW - Nanoplastics KW - ILC KW - DLS KW - Polypropylene PY - 2025 AN - OPUS4-64714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, Paul T1 - Microanalysis of Airborne Nano/Microplastic Particles in an Textile Industrial Environment N2 - Micro- and nanoplastics (MNPs) are emerging global contaminants, present in air, soil, and water. The textile industry is potentially a major contributor, releasing synthetic particles like polyamide, polyester, and acrylic during production. This study assessed MNP levels outside and inside a textile-processing facility using online air samplers with silicon (Si) and quartz filters. Real-time particle counts (PM0.3–PM10) were obtained via a laser detector. Si filters (9 mm, 10/1 µm pores) and quartz filters (25 mm, 1.2 µm pores, pre-calcined at 800°C) were used for sampling. Custom holders allowed selective sampling for PM10 and PM1 on Si filters. Sampling conditions included a 3-hour collection at 2 L/min (GilAir Plus pump) starting at 7:00 AM (T1) and 2:00 PM (T2), with intermittent ventilation, 23.3 °C average temperature, and 52.5% humidity. Particle weights collected (µg) were: quartz – 4.9E-05 (T1), 5.1E-05 (T2); Si – 3.2E-05 (T1), 5E-06 (T2). Outside particle counts ranged from 3,584 (T1) to 15,165 (T2); inside: 9,901 (T1) to 12,921 (T2). Maximum indoor PM10 and PM0.3 levels were 72/m³ and 71,979/m³, respectively. Particles were analyzed using electron microscopy and µRaman spectroscopy, confirming high concentrations of irregularly shaped PP-based particles (1–5 µm). T2 - 12th TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Airborne particles KW - Raman microspectroscopy PY - 2025 AN - OPUS4-64485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Portela, Raquel A1 - Barbero, Francesco A1 - Breuninger, Esther A1 - Camassa, Laura Maria Azzurra A1 - Velickovic, Tanja Cirkovic A1 - Charitidis, Costas A1 - Costa, Anna A1 - Fadda, Marta A1 - Fengler, Petra A1 - Fenoglio, Ivana A1 - Giovannozzi, Andrea M. A1 - Haugen, Øyvind Pernell A1 - Kainourgios, Panagiotis A1 - von der Kammer, Frank A1 - Kirchner, Markus J. A1 - Lomax-Vogt, Madeleine A1 - Lujic, Tamara A1 - Milczewski, Frank A1 - Moussawi, Mhamad Aly A1 - Ortelli, Simona A1 - Parac-Vogt, Tatjana N. A1 - Potthoff, Annegret A1 - Jimenez Reinosa, Julian J. A1 - Röschter, Sophie A1 - Sacco, Alessio A1 - Wimmer, Lukas A1 - Zanoni, Ilaria A1 - Dailey, Lea Ann T1 - Characterizing nanoplastic suspensions of increasing complexity: inter-laboratory comparison of size measurements using dynamic light scattering N2 - Understanding the potential human health risks associated with micro- and nanoplastic exposure is currently a priority research area. Nanoplastic toxicity studies are complicated by the lack of available, well-characterized test and reference materials. Further, many nanoplastic test materials are inherently more polydisperse and heterogenous in shape compared to polystyrene beads, making accurate and representative size distribution measurements particularly challenging. The aim of this study was to conduct an inter-laboratory comparison of dynamic light scattering measurements, the most commonly used particle sizing method for nanomaterials. Using a published standard operating procedure, size measurements in water and a standardized cell culture medium (CCM) were generated for spherical, carboxy-functionalized polystyrene nanoparticles (PS-COOH; 50 nm; benchmark material), and for increasingly complex in-house produced spherical poly(ethylene terephthalate) (nanoPET) and irregular shaped polypropylene (nanoPP) test materials. The weighted mean of hydrodynamic diameters of PS-COOH dispersed in water (55 ± 5 nm) showed moderate variation between labs (coefficient of variation, CV = 8.2%) and were similar to literature reports. Measurements of nanoPET (82 ± 6 nm) and nanoPP (182 ± 12 nm) in water exhibited similar CV values (nanoPET: 7.3% and nanoPP; 6.8%). Dispersion of PS-COOH and nanoPET in CCM increased the CV to 15.1 and 14.2%, respectively, which is lower than literature reports (CV = 30%). We conclude with a series of practical recommendations for robust size measurements of nanoplastics in both water and complex media highlighting that strict adherence to a standard operating procedure is required to prevent particle agglomeration in CCM KW - Nanoplastics KW - Reference materials KW - Polypropylene PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-644571 DO - https://doi.org/10.1039/d5en00645g SN - 2051-8153 SP - 1 EP - 15 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64457 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna T1 - Reference material BAM-P206 polyethylene terephthalate (powder) N2 - This report contains detailed information on the preparation of the reference material as well as on homogeneity and stability investigations of the property of interest, the equivalent particle diameter, and on the analytical methods to determine the additional properties. The values for particle size distribution are based on the results from laser diffraction measurements of 3 different devices with at least 3 replicate measurements of 4 randomly chosen units of the reference material P206. KW - Microplastic KW - Reference material KW - PET PY - 2023 DO - https://doi.org/10.26272/opus4-59778 SP - 1 EP - 23 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-59778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kittner, Maria A1 - Altmann, Korinna A1 - Hamann, Sven A1 - Weyer, Rüdiger A1 - Kalbe, Ute T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis - Abschlussbericht N2 - Die Europäische Kommission hat 2023 ein Verbot zum bewussten Austrag von Mikroplastik (MP) in die Umwelt beschlossen, das auch für die Verwendung von synthetischen Gummi-Granulaten (v. a. EPDM) in Sportböden gilt. In Deutschland gibt es laut DFB ca. 5100 Kunstrasenplätze. In der EU beläuft sich die Anzahl laut ECHA auf 13,000 Kunstrasen- und 47,000 Bolzplätze, Tendenz steigend. Das Hauptziel des Projektes war es daher, eine Massenbilanz für die Freisetzung von MP zu erstellen, um so eine Schätzung des MP-Austrags pro Kunstrasenplatz und Jahr zu ermöglichen. Dafür werden die MP-Emissionen von drei Kunstrasenszenarien in verschiedenen Zuständen (ungealtert, künstlich gealtert und in Echtzeit gealtert) verglichen: die Vergangenheit (Kunstrasen: fossilbasiert, EPDM-Füllung), die Gegenwart (der in Europa am häufigsten installierte Rasen) und die Zukunft (Rasen mit recycelten Grasfasern, keine synthetische Füllung sondern z.B. Quarzsand oder Korkschrott). Dazu werden fabrikneue Kunststoffrasen und EPDM-Granulat unter Laborbedingungen beschleunigt gealtert, um die Freiland-Beanspruchung eines Kunststoffrasens in circa 15 Jahren abzubilden. Die Verwendung spezieller Mikrofiltertiegel in Lysimeter-Experimenten ermöglicht die Abschätzung der Partikelgrößen des emittierten MP, was eine Grundbedingung für die Bewertung einer potenziellen Gesundheitsgefährdung für Menschen ist. Ergänzend wurden weitere umweltrelevante Schadstoffausträge aus den Kunststoffrasen quantifiziert. KW - Mikroplastik KW - Kunststoffrasen KW - Schadstoffe KW - Bewitterung KW - Lysimeter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633114 DO - https://doi.org/10.26272/opus4-63311 N1 - Das Projekt wurde gefördert vom Bundesinstitut für Bau-, Stadt- und Raumforschung (BBSR) im Auftrag des Bundesministeriums für Wohnen, Stadtentwicklung und Bauwesen (BMWSB) aus Mitteln des Innovationsprogramms Zukunft Bau. Aktenzeichen: FKZ 10.08.18.7-22.02. Projektlaufzeit: 09.2022 bis 03.2025. SP - 1 EP - 75 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-63311 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -