TY - CONF A1 - Hülagü, Deniz A1 - Ermilova, Elena A1 - Weise, Matthias A1 - de Préville, Sophie A1 - Hoffmann, Johannes A1 - Morán-Meza, José A1 - Piquemal, Francois A1 - Hertwig, Andreas T1 - Characterization of electrical properties in microstructured ITO layers using spectroscopic ellipsometry N2 - Thin indium tin oxide (ITO) layers are essential in optoelectronics due to their good electrical conductivity, optical transparency in the visible and near infrared regions, substrate adherence and chemical stability. They are widely used in photovoltaic cells, displays, and organic LEDs, and as low emissivity coatings in smart windows and energy-efficient buildings. For nanophotonic devices, understanding the interplay of ITO’s optical and electrical properties is crucial. Electrical resistivity can be tuned by modifying deposition conditions and layer thickness. However, measuring these properties, especially on microstructured surfaces, remains challenging due to the issues like homogeneity and instability during etching. Spectroscopic ellipsometry (SE), a non-destructive and phase-sensitive optical technique, offers precise measurement of thin film thickness and dielectric properties. In this study, we investigated the layer thickness, optical constants, and sheet resistance of unstructured and microstructured ITO thin layers using SE. Unstructured layers were deposited via DC-magnetron sputtering on silicon (Si) substrates in argon (Ar) atmospheres with varying oxygen (O2) flows. This multi-technique approach enhances the understanding of ITO layer structuring and provides robust methodologies for correlating optical and electrical properties, advancing metrology for nanotechnology applications and material science. It also opens the pathway to new reference samples and calibration methods for electrical properties involving device-like structured samples. T2 - ICSE10 - 10th International Conference on Spectroscopic Ellipsometry CY - Boulder, CO, USA DA - 08.06.2025 KW - Ellipsometry KW - Indium tin oxide (ITO) KW - Scanning microwave microscopy (SMM) KW - Sheet resistance calibration standards KW - ITO wet etching PY - 2025 AN - OPUS4-63631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fink, Friedrich A1 - Stawski, Tomasz M. A1 - Emmerling, Franziska A1 - Falkenhagen, Jana T1 - A novel machine-learning approach to unlock technical lignin classification by NIR spectroscopy - bench to handheld N2 - In this research, the utilization of near-infrared (NIR) spectroscopy in conjunction with advanced machine learning methods is investigated for categorizing technical lignins obtained from different biomass sources and industrial procedures. Technical lignins, such as kraft, organosolv and lignosulfonates, have different chemical compositions, which continue to make uniform characterization and application in sustainable sectors extremely difficult. Fast, universally accessible analytics combined with data analysis is still an open question. For the first time three distinct NIR spectrometers—a high-performance benchtop system, a mid-priced compact device, and an economical handheld unit—were utilized to record NIR spectra of 31 unique lignin samples. The spectra underwent pre-processing through standard normal variate (SNV) transformation and Savitzky-Golay derivatives to amplify spectral features and decrease noise. Principal component analysis (PCA) was employed to reduce data complexity and extract crucial characteristics for classification purposes. Subsequently, four machine learning algorithms—Support Vector Machines (SVM), Gaussian Naive Bayes (GNB), Gaussian Process Classification (GPC), and Decision Tree Classification (DTC)—were implemented for the classification of the lignin samples. The DTC model exhibited the highest accuracy among them across different spectrometers. Although the benchtop spectrometer produced the most precise outcomes, the compact NeoSpectra system also displayed potential as a cost-efficient option. Nonetheless, the restricted spectral coverage of the handheld NIRONE spectrometer resulted in reduced classification accuracy. Our discoveries highlight the capability of NIR spectroscopy, combined with robust data analysis techniques, for the swift and non-destructive classification of technical lignins, facilitating their improved utilization in sustainable fields. KW - Technical lignins KW - NIR spectroscopy KW - Classification KW - Machine-learning KW - PCA PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-634518 DO - https://doi.org/10.1016/j.chemolab.2025.105467 SN - 0169-7439 VL - 264 SP - 1 EP - 10 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-63451 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Goedecke, Caroline A1 - Bannick, C.-G. A1 - Abusafia, A. A1 - Scheid, C. A1 - Steinmetz, H. A1 - Paul, Andrea A1 - Beleites, C. A1 - Braun, U. T1 - Identification of microplastic pathways within a typical European urban wastewater system N2 - In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other. KW - Microplastics KW - Microplastic analysis KW - TED-GC/MS KW - Microplastic pathways KW - Mass contents PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568289 DO - https://doi.org/doi.org/10.1002/appl.202200078 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, U. T1 - Detection of plastics in soil N2 - Soil acts as a final sink for pollutants. Microplastics from different sources such as plastic mulching, littering, compost, sewage sludge, sedimentary deposition, and tyre abrasion are expected to be found in soil. However, representative and comprehensive information is missing on the sources, transport, and fate. Therefore, a reliable analysis method for microplastics in soils needs to be developed. The presented work describes the development of a procedure for microplastics analysis in soils. A representative sampling based on the on-site conditions and a sample preparation method was established and comprised of a drying step, the separation of microplastic particles > 1 mm, and a density separation for particles < 1 mm. The detection of the large microplastic particles (> 1 mm) was conducted with Attenuated Total Reflection - Fourier Transform infrared Spectroscopy (ATR-FTIR) , while Thermal Extraction Desorption - Gas Chromatography / Mass Spectrometry (TED-GC/MS) was applied for particles < 1 mm, gaining information on the type of polymer and mass fraction. Based on the established method, 14 environmental soil samples ? with different exposure of microplastics from agriculture, industrial sites, roads, and floods were investigated. Due to the arbitrary microplastic particle distribution among the samples for large microplastics, it was reasoned that the found particles were unrepresentative. In contrast, microplastic particles < 1 mm were discovered in a high mass in soil samples exposed to plastic mulching or fertilization with sewage sludge or compost (0 – 115 mg/kg). On average, microplastic contents detected in soil samples taken from a construction site and an inner-city lake were higher (13 – 238 mg/kg). As expected, microplastic content in soil sampled in proximity to roads was more pronounced in the upper soil layers. In contrast, very remote sampling sites, expectably uncontaminated, did not lead to the detection of microplastic regarding to thermoanalytical detection method. In a proof of concept experiment several in vivo and in vitro ecotoxicological tests were applied to evaluate the effect of microplastics (tyre abrasion, polystyrene containing hexabromocyclododecane) in natural soils. In summary, while no effects of the examined probes could be detected on higher levels of biological organization after exposures to earthworm E. andrei, significant changes in several oxidative stress related biomarkers were observed. T2 - SETAC Europe 2022 CY - Kopenhagen, Denmark DA - 15.05.2022 KW - Microplastic KW - TED-GC/MS KW - Soil PY - 2022 AN - OPUS4-55872 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Plastik in Böden: Mikroplastik-Ergebnisse N2 - In diesem Vortrag geht um die Vorstellung der Ergebnisse des UBA Projektes Plastik in Böden. Es werden Mikroplastik-Gehalte in verschiedenen Böden präsentiert. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - Mikroplastik Böden KW - Mikroplastik-Analytik PY - 2022 AN - OPUS4-54648 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik an der BAM: TED-GC/MS und Referenzmaterialien N2 - Thema ist die Funktionsweise der TED-GC/MS als Methode für die Mikroplastik-Detektion sowie die Herstellung dazugehöriger Referenzmaterialien an der BAM T2 - 25. Kolloquium Massenspektrometrie von Polymeren CY - Online meeting DA - 17.06.2021 KW - Mikroplastik KW - TED-GC/MS KW - Referenzmaterial PY - 2021 AN - OPUS4-52835 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Linberg, Kevin T1 - Controlled Polymorphism by Elevated Temperature Ball Milling N2 - Mechanochemistry provides polymorphs that are difficult to obtain by conventional solution-based methods. Based on the nicotinamide and pimelic acid cocrystal, we demonstrated that the ball size, frequency, and temperature are essential parameters. Our results indicate that fine-tuning the energy input during a mechanochemical reaction can provide control over polymorphism. T2 - Bessy User Meeting 2023 CY - Berlin, Germany DA - 22.06.2023 KW - Mechanochemistry KW - Temperature KW - Cocrystal KW - Energy input KW - Polymorph PY - 2023 AN - OPUS4-57985 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Reference material candidates for microplastic analysis N2 - Every day, there are new headlines in the media about microplastics (1-1000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) findings all over the planet with high variations in particle number and mass. The challenges in analytics are very complex, e.g. representative sampling, non-destructive sample preparation with concentrated particles and homogeneous distribution and true detection. All together lead to lacks in harmonization and results, which are hardly comparable. On the other hand, monitoring of microplastics is mandatory in the future strictly regulated by the EU commission in the Drinking water and Wastewater Framework Directive. One step to accurate and precise results will be the development of suitable reference materials mimicking particles in the environment. BAM developed test materials, which are produced by mixing a small portion of microplastic particles with a water-soluble matrix. After solid phase dilution and homogenisation small portions are pressed into tablets and bottled in glass vials (Figure 1). These tablets are well characterized with particle size distribution and SEM images. Additionally, they are tested as reference material candidate according to homogeneity and stability for particle number with µ-IR and µ-Raman as well as on particle mass with Py-GC/MS and TED-GC/MS after ISO Guide 35. Results are promising. The material passed the homogeneity control. No changes are observed within 6 months of storage. The same tested reference material is finally used in sample preparation experiments, where environmental suspended particular matter from surface water or baby milk powders are spiked with the tablets. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polymer 3R KW - Tablets PY - 2024 AN - OPUS4-61017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Rapid sample preparation to detect microplastics in baby milk powder N2 - Microplastics, ubiquitous as it is, could be released into food during production chain, through packaging and by consumer´s use. To determinate human exposure to microplastics is crucial to monitor microplastics in food matrices. The current absence of standard sample preparation procedures to identify and quantify different microplastics according to number and mass have generate time-consuming protocols and lack of comparability among different analytical methods, laboratories and time scales. Monitoring microplastics in complex matrices as food, and in particular in baby milk powder, requires an accurate approach that need to be validate, to ensure the comparability of results. Bottled drinking water or surface waters, for example, can be measured with mass-based methods (TED-GC/MS or Py-GC/MS) directly after filtration. Baby milk powder, instead is more challenging, due to the proteins and fatty acid that clog the filters and contaminate the measuring devices with heavy carry over. In this study, we characterize the baby milk powder by thermogravimetric analysis (TGA) and we tested different treatments for matrix reduction: water, H2O2, citric acids. In particular, the use of citric acid was tested for protein reduction before filtration. Our hypothesis was that citric acid will induce the precipitation of proteins and amino acids, leading to a strong matrix reduction. In fact, this sample pre treatment, allowed us to use a higher intake, necessary for representative quantification. Finally, the milk powder was spiked with reference material tablets containing polyethylene terephthalate (PET). The PET was not degraded by the citric acid and high recovery rate was achieved by TED-GC/MS and Py-GC/MS methods. Considering the simplicity and accessibility of this sample preparation and its robust results, this procedure could be easily proposed as a simple sample preparation approach to monitor microplastics by mass-based methods. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Milk KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Plastik in Böden: Mikroplastik-Analytik N2 - Im Vortrag wir eine Methode zur Analyse von Mikroplastik in Böden dargestellt. Es geht dabei um die Probenvorbereitung und Detektion. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik KW - Methodenentwicklung Böden PY - 2022 AN - OPUS4-54646 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Qualitätssicherung bei der Analyse von Mikroplastik per TED GC/MS N2 - Die Thermo Extraktion Desorption Gas Chromatograpie Massen Spektrometrie (TED-GC/MS) ist ein schnelles thermoanalytisches Verfahren zur Bestimmung von Gehalten an Mikroplastik (MP). Die Kombination aus teils schwerflüchtigen Analyten und Kältebrücken führt zu Memory-Effekten, denen u.a. durch häufige Blindwertmessungen begegnet werden muss. Reduzierte Probedurchsätze sind die Folge. Um Messergebnisse abzusichern und den Gerätestatus bei gleichzeitig hoher Messleistung überwachen zu können, wurde die sequentielle Standardmethode überarbeitet. T2 - Tagung der Wasserchemischen Gesellschaft 2022 CY - Online meeting DA - 23.05.2022 KW - Mikroplastik KW - Thermoanalytik KW - TED-GC/MS KW - Qualitätssicherung PY - 2022 AN - OPUS4-55087 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Harmonisation efforts of the CUSP projects N2 - The talk is about harmonisation approaches within CUSP. First the five H2020 projects for research on risk assessment regarding microplastics topic were presented. Secondly, harmonisation process were discussed. T2 - VAMAS SC 47 Meeting CY - Turin, Italy DA - 19.10.2022 KW - Microplastics KW - Harmonisation KW - Nanoplastics KW - H2020 KW - Risk assessment PY - 2022 AN - OPUS4-56077 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bauer, J. A1 - Miclea, P.-T. A1 - Braun, U. A1 - Altmann, Korinna A1 - Turek, M. A1 - Hagendorf, C. T1 - Microplastic detection and analysis in water samples N2 - Microplastic detection in water samples becomes important for tracing microplastic sources. Microplastic may harm desalination facilities by blocking filters and disturbing the marine food chain. Thermo analytical methods such as pyrolysis gas chromatography mass spectroscopy, and spectroscopic methods like (micro) Raman spectroscopy or (micro) Fouriertransform infrared spectroscopy in combination with appropriate filters and sample preparation are suitable for analyzing microplastics on a scale from 1 µm to 1000 µm fast and unambiguous. While the thermo analytical methods are suitable for larger sample volumes, Raman spectroscopy and Fouriertransform infrared spectroscopy are able to detect and analyze single microplastic particles for instance in bottled water. Machine learning algorithms ensure a reliable classification of different plastic materials. T2 - International Conference on Sustainable Energy-Water-Environment Nexus in Desert Climate 2019 CY - Ar-Rayyan, Qatar DA - 02.12.2019 KW - Microplastics KW - Water samples PY - 2022 SP - 111 EP - 113 PB - Springer AN - OPUS4-56240 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Detektion von Mikroplastik N2 - In dem Vortrag geht es um die Möglichkeiten der Detektion von Mikroplastik im Allgemeinen. Es werden Beispiele für die Luft gezeigt. T2 - VDI-Workshop „Mikroplastik in der Außenluft – Was wir wissen und was wir (noch) nicht wissen CY - Online meeting DA - 15.11.2022 KW - Mikroplastik KW - Mikroplastik in Luft KW - Detektion von Mikroplastik PY - 2022 AN - OPUS4-56289 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, U. T1 - Thermoanalytical methods to measure mass in microplastics N2 - The talk adresses the use of thermoanalytical methods in microplastics analysis. T2 - EUROLAB webinar: MICROPLASTICS: regulations, standards and the role of laboratories CY - Online meeting DA - 15.02.2023 KW - TED-GC/MS KW - Thermoanalytical methods KW - Microplastic mass PY - 2023 AN - OPUS4-57009 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Stakeholder Workshop – Plastictrace WP1 N2 - The talk is about WP1 in the PlasticTrace project funded by Euromat. The projects harmonizes microplastic analysis by developing SOPs and reference materials. WP1 is responsible for material selection and preparation. All particles are homogeneity and stability checked according to ISO guide 35. T2 - Stakeholder workshop of PlasticTrace project CY - Online meeting DA - 14.12.2022 KW - Microplastic KW - Microplastics standardisation KW - Reference materials PY - 2022 AN - OPUS4-56772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna A1 - Abusafia, A A1 - Bannick, C-G A1 - Braun, U A1 - Crasselt, Claudia A1 - Dittmar, S A1 - Fuchs, M A1 - Gehde, M A1 - Hagendorf, C A1 - Heller, C A1 - Herper, D A1 - Heymann, S A1 - Kerndorff, A A1 - Knefel, M A1 - Jekel, M A1 - Lelonek, M A1 - Lunkenbein, T A1 - Obermaier, N A1 - Manhart, M A1 - Meurer, Maren A1 - Miclea, P-T A1 - Paul, A A1 - Richter, S A1 - Ricking, M A1 - Rohner, C A1 - Ruhl, A A1 - Sakai, Y A1 - Saravia Arzabe, C A1 - Scheid, C A1 - Schmitt, M A1 - Schnarr, M A1 - Schwertfirm, F A1 - Steinmetz, H A1 - Wander, Lukas A1 - Wiesner, Yosri A1 - Zechmeister, L T1 - RUSEKU - Repräsentative Untersuchungsstrategien für ein integratives Systemverständnis von spezifischen Einträgen von Kunststoffen in die Umwelt : Abschlussbericht N2 - Im Verbundprojekt RUSEKU wurde die Probenahme von Wasserproben entscheidend weiterentwickelt. Wichtig ist hierbei zu gewährleisten, dass genügend Merkmalsträger in jeder Probe untersucht werden. Es muss daher eine für den Probenahmeort repräsentative Beprobung hinsichtlich des Wasservolumens in Abhängigkeit der Partikelanzahl gewährleistet sein. Das Hauptaugenmerk lag im vorliegenden Projekt auf einer praxisnahen Beprobungsstrategie. Es wurden verschiedene Konzepte ausprobiert. • Grundsätzlich hat sich gezeigt, dass eine Stichprobe eine Momentaufnahme des MP-Massengehaltes zeigt. Es wird eine hohe Statistik, also eine Vielzahl an Messungen am gleichen Probenahmeort, benötigt, um eine valide Aussage über den MP-Gehalt zu machen. • Es zeigt sich, dass eine integrale Probenahme über mehrere Wochen mit dem SK routinemäßig möglich ist. Die erfassten MP-Massen sind reproduzierbar und robust. • Die DFZ ist für Stichproben geeignet. Partikel < 50 µm werden eventuell unterschätzt • Die fraktionierte Filtration kann für Stich- und Mischproben direkt im Feld genutzt werden. Fraktionen von 10 und 5 µm werden später im Labor Vakuum filtriert. Es erfolgt eine Fraktionierung der Probe mit Siebmaschenweiten von 1000, 500, 100, 50, 10 und 5 µm. • Die fraktionierte Filtration kann auch anschließend an die Beprobung mit dem SK zur Anwendung kommen. Wird die mit dem SK gewonnene Wasserprobe fraktioniert filtriert, kann neben einem MP-Gesamtgehalt auch eine Einschätzung über die Partikelgrößen gewonnen werden. • Für Wässer mit geringen Partikelzahlen wurde ein Messfiltertiegel entwickelt. Dieser hat eine Maschenweite von 6 µm. Seine Anwendung kann mögliche Verluste beim Transferieren vom Probenahmetool zum Messgefäß und mögliche Kontaminationen reduzieren. Die Optimierung der Probenahmestrategie wurde durch Modellversuche und Simulationen unterstützt. Modellversuche zum Sinkverhalten und Simulationen von MP in realen Gewässern verdeutlichten das komplexe Verhalten der Partikel. Es konnte gezeigt werden, dass Partikel ab einer bestimmten Größe (und kleiner) bei genügend starker Turbulenz sich in der Wassersäule unabhängig von ihrer Dichte verhalten und so auch MP mit kleiner Dichte (z.B. PE) in der gesamten Wassersäule zu finden sind. Es konnte mit dem TEM die Existenz von NP gezeigt werden. Ein wesentlicher Aspekt des RUSEKU Projektes war die Beprobung realer Kompartimente. Beprobt wurde neben Oberflächengewässern, das urbane Abwassersystem der Stadt Kaiserslautern, Waschmaschinenabwasser und Flaschenwasser. • In Oberflächengewässern wurde hauptsächlich PE gefunden. Je nach Probe und Gewässer konnten auch PP, PS, PET, PA, SBR und Acrylate nachgewiesen werden. • Im urbanen Abwassersystem der Stadt Kaiserslautern konnte an allen Probenahmestandorten MP nachgewiesen werden. Es wurde hauptsächlich PE, neben geringeren Mengen an PP, PS und SBR gefunden. Nach einem Regenereignis war der SBR Anteil deutlich erhöht. • Die Beprobung eines realen Wäschepostens, bestehend aus T-Shirts und Hemden mit PA/CO oder PES/CO Mischgewebe, zeigte einen PA- und PES-Austrag im Waschwasser. Der überwiegende Teil der detektierten Fasern ist aber auf Baumwolle zurückzuführen. Reine gravimetrische Messungen zur Detektion von MP führen zu einer starken Überschätzung. • In Flaschenwasser (PET-Flaschen) konnte MP detektiert werden. PET wurde nur im stillen Mineralwasser, nicht in Mineralwasser mit Kohlensäure gefunden werden. Teilweise wurde auch das MP-Material des Verschlusses im Wasser detektiert. • Für Luftproben konnte ein Aufbau zur größenselektiven Beprobung getestet werden. Neben der Probenahme hat das Projekt auch gezeigt, dass die TED-GC/MS geeignet für die MP-Detektion im Routinebetrieb ist. Die TED-GC/MS konnte weiter optimiert werden. Es wurden MP-Massen bestimmt. Im Projekt wurden erste realitätsnahe Referenzmaterialien für die MP Detektion hergestellt. Die Herstellung von realitätsnahen Polymeren in ausreichender Homogenität und Menge hat sich als große Herausforderung herausgestellt. KW - Mikroplastik KW - Probennahme KW - TED-GC/MS KW - Fraktionierte Filtration KW - Mikroplastikreferenzmaterial PY - 2022 SP - 1 EP - 201 AN - OPUS4-57800 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiesner, Yosri T1 - Erfassung von Degradationsprodukten und Additiven sowie temperaturspezifische Pyrolyseprodukte mittels TED-GC/MS N2 - Im der Präsentation werden, neben der Möglichkeit der Mikroplastikquantifizierung, auf weitere Anwendungsfelder der Methode TED-GC/MS eigegangen. Dies beinhaltet die Erfassung von Degradationsprodukten UV/O2 geschädigter Polymere und die Detektion von Additiven. Die Optimierung der Methode betreffend Messzeit und materialspezifischer Messanforderung sind ebenfalls Gegenstand. T2 - Kolloquium Massenspektrometrie von Polymeren CY - Berlin, Germany DA - 09.05.2023 KW - TED-GC/MS KW - Polymere KW - Degradation KW - Additive PY - 2023 AN - OPUS4-57480 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Improvements in micro- & nanoplastic mass detection by TED-GC/MS N2 - Introduction to microplastics, definition, relevance, analytical approaches & challenges. TED-GC/MS working principle, features & performance. Optimisation in TED-GC/MS methodology, new validation data. Replacement of Internal Standard, outlook towards upcoming publication and application within EU´s revised drinking water directive. T2 - SETAC 2023 CY - Dublin, Ireland DA - 01.05.2023 KW - Microplastics KW - Thermoanalytics KW - Validation KW - Internal Standard PY - 2023 AN - OPUS4-57421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Real-life airborne micro- and nano-plastic particles and fibres on a porous membrane filter system from a textile factory suitable for both: vibrational and mass spectrometry N2 - The poster presents an application of Si wafer filter system on indoor air sampling. A textile factory producing PP fibres was sampled. T2 - SETAC Europe 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - Microplastics KW - Polymer 3R KW - Textile fibres KW - Si wafer filter KW - Microplastics sampling PY - 2023 AN - OPUS4-57462 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Micro- and nanoplastic particle number and mass-based analysis on a plastic-free size-selective two stage Si membrane filtration cascade N2 - The poster presents a Si wafer filter development as two stage cascade and the adapter for microplastics filtration. T2 - SETAC Europe 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - Microplastics KW - Filtration KW - TED-GC/MS KW - Polymer 3R KW - Cascade filtration PY - 2023 AN - OPUS4-57461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Bednarz, Marius A1 - Braun, Ulrike A1 - Bannick, Claus Gerhard A1 - Ricking, Mathias A1 - Altmann, Korinna T1 - A promising approach to monitor microplastic masses in composts N2 - Inputs of plastic impurities into the environment via the application of fertilizers are regulated in Germany and the EU by means of ordinances. Robust and fast analytical methods are the basis of legal regulations. Currently, only macro- and large microplastic contents (>1 mm) are measured. Microplastics (1–1,000 µm), are not yet monitored. Thermal analytical methods are suitable for this purpose, which can determine the mass content and can also be operated fully automatically in routine mode. Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) allows the identification of polymers and the determination of mass contents in solid samples from natural environments. In accordance with the German or European Commission (EC) Fertiliser Ordinance, composting plants should be monitored for microplastic particles with this method in the future. In this context a compost plant was sampled. At the end of the rotting process, the compost was sieved and separated in a coarse (>1 mm) and a fine fraction (<1 mm). The fine fraction was processed using density separation comparing NaCl and NaI as possible salt alternative and screened for microplastic masses by TED-GC/MS with additional validation and quality assurance experiments. With TED-GC/MS total microplastics mass contents of 1.1–3.0 μg/mg in finished compost could be detected with polyethylene mainly. What differs much to the total mass of plastics in the coarse fraction with up to 60 μg/mg, which were visually searched, identified via ATR-FTIR and gravimetrically weighted. KW - Microplastics KW - TED-GC/MS KW - Compost KW - Monitoring KW - Soil PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-586688 DO - https://doi.org/10.3389/fenvc.2023.1281558 SN - 2673-4486 VL - 4 SP - 1 EP - 12 PB - Frontiers Media CY - Lausanne AN - OPUS4-58668 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik Detektion mit Thermoanalytischen Methoden: Analytik, Referenzmaterial, Ringversuche N2 - Ich dem Vortrag geht es um die Vorstellung von thermoanalytischen Methoden für die Mikroplastik-Detektion. Verschiedene Kopplungsmöglichkeiten werden gezeigt und die Funktionsweise der TED-GC/MS wird erklärt. Im zweiten Teil werden Referenzmaterialien für die Mikroplastik-Analytik diskutiert. PET -Tabletten des PlasticTrace Projektes werden vorgestellt. Am Ende wird der VAMAS Ringversuch zur Mikroplastik-Detektion gezeigt. T2 - Plastik, Mikroplastik, Nanopartikel, PFAS und Verunreinigungen (Agilent Workshop) CY - Hamburg, Germany DA - 28.05.2024 KW - Mikroplastik KW - TED-GC/MS KW - Polymer 3R KW - Ringversuche KW - Referenzmaterial PY - 2024 AN - OPUS4-60155 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Béalu, Zoé A1 - Walther, Johanna A1 - Abusafia, Attaallah A1 - Altmann, Korinna A1 - Meurer, Maren A1 - Gretzschel, Oliver A1 - Schäfer, Michael A1 - Steinmetz, Heidrun T1 - Removal of Organic Micropollutants and Microplastics via Ozonation Followed by Granular Activated Carbon Filtration N2 - Discharge from Wastewater Treatment Plants (WWTPs) can result in the emission of organic micropollutants (OMPs) and microplastics (MPs) into the aquatic environment. To prevent this harmful release, a pilot plant consisting of an ozonation followed by a granular activated carbon (GAC) filter was operated at a WWTP in Germany, and its side-effects on the concentrations of nitrogen (N) and phosphorous (P) compounds were measured. Over 80% of OMPs and transformation products were removed during the operating time (around 6000 bed volumes) no matter the ozone dose (from around 0.1 to 0.5 mgO3/mgDOC), except for Diatrizoic acid, whose breakthrough appeared at 3500 BV. Formation of the oxidation by-product, NDMA, increased with higher ozone doses, but the concentration remained below 100 ng/L. Bromate was formed at a higher ozone dose (0.4 mgO3/mgDOC) but at a low concentration—below 10 µg/L. The MP particles detected in the inflow (PE, SBR, PP, and PS) were effectively eliminated to a high degree, with a removal rate of at least 92%. Carbon parameters (COD, DOC, and SAC254) were removed further by the pilot plant, but to different extents. As expected, nitrate was formed during ozonation, while nitrite’s concentration decreased. Further, nitrite decreased and nitrate increased within the GAC filter, while ammonium was eliminated by at least 90%. Total P concentration decreased after the pilot, but the concentration of PO4-P increased. KW - Microplastics KW - TED-GC/MS KW - Granular Activated Carbon Filtration KW - Removal of Organic Micropollutants KW - Wastewater treatment plant PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615209 DO - https://doi.org/10.3390/environments11110241 VL - 11 IS - 11 SP - 1 EP - 38 PB - MDPI AG AN - OPUS4-61520 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik heute: Was haben wir in den letzten Jahren erreicht? N2 - In diesem Vortrag geht es um eine Übersicht über die Thematik der Mikroplastik, Was ist Mikroplastik, wie entsteht es und wo kommt es her. Es wird beschrieben wie eine repräsentative Probenahme erfolgen kann und wie welche Herausforderungen bei der Probenvorbereitung existieren. Die Detektion wird ausführlich beschrieben, sowohl mit Partikelanzahl als auch Masse. Im weiteren werden erste Referenzmaterialien und ihre Anwendung in internationalen Ringversuchen beschrieben. Der zweite Teil zeigt die Normungsaktivitäten im Bereich der Mikroplastik. T2 - Mitgliederversammlung der GdCh Lackchemie CY - Online Meeting DA - 20.09.2024 KW - Mikroplastik KW - TED-GC/MS KW - Polymer 3R KW - Reference material KW - ILC on detection methods PY - 2024 AN - OPUS4-61087 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Seasonal microplastic concentrations along the rivers Rhine and Danube N2 - Over the last 20 years, many researchers, politicians and citizens have become increasingly aware of the growing plastic problem of our time. A lack of recycling concepts and plastic collection points as well as careless dumping lead to accumulation of plastic products in the environment. Natural weathering can cause these plastics to degrade and fractionate, meaning that microplastics (1 1,000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) of various synthetic polymer materials can now be detected in all parts of the world. Whether microplastics or nanoplastics pose a toxicological hazard is being investigated in a variety of ways. Valid results are still pending. However, the EU precautionary principle applies to micro- and nanoplastics. Monitoring of microplastics is already required in the revision of the Drinking Water and Wastewater Framework Directive. Reliable monitoring of rivers can be carried out by sampling with sedimentation boxes and microplastic detection by using thermal extraction desorption gas chromatography/mass spectrometry (TED-GC/MS) in routine operation (Figure 1). The river Rhine was sampled for microplastic masses at three different sampling locations over a period of one year and in addition the Danube at randomized sampling locations The TED-GC/MS results showed that various synthetic polymers frequently produced in industry, such as polyethylene, polypropylene or polystyrene as well as the tire compound styrene-butadiene rubber were found. The work not only shows a possible workflow for monitoring concepts, but also provides information on environmentally relevant concentrations of microplastics and tire components in surface waters. This in turn is necessary for ecotoxicological studies. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Polymer 3R PY - 2024 AN - OPUS4-61016 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Visileanu, Emilia A1 - Catalin Grosu, Marian A1 - Tiberiu Miclea, Paul A1 - Altmann, Korinna A1 - Brossell, Dirk T1 - Methods for the collection and characterization of airborne particles in the textile industry N2 - Airborne particulate matter is one of the main air pollutants. Their impact on mortality, and the occurrence of pulmonary and cardiovascular complications, have been the subject of numerous studies. Airborne particles are complex mixtures of organic and inorganic substances from different sources of particle emissions. Particulate Matter (PM) particles are classified according to their aerodynamic diameter expressed in µm and can vary from coarse (PM 10) to fine (less than PM 2.5). These diameter considerations are fundamental because they condition the penetration of particles into the bronchopulmonary system and the body. In recent years, there has been an interest in so-called “ultra-fine” particles, with a diameter of 0.1 µm (or 100 nm), or PM 0.1. They are nanoparticles and their impact on human health is not yet clear.With more than 1.5 million employees, textiles and clothing is a diverse sector that plays an important role in the European manufacturing industry, producing a turnover of €162 billion.An important component of the solid particles that generate air pollution in the textile industry is microplastics (MP) and nano plastics (NP), which also include microfibers (<5mm) and nanofibers (<100 nm), respectively. The particles released into the air during fiber and yarn processing range from 1 µg/m3 to 50 µg/m3.The paper presents the results of the determination of indoor and outdoor air concentration levels in textile companies, to identify the areas with the highest concentration level, by using an online recording system such as the Laser Aerosol Spectrometer MINI LAS model 11-E. The total concentration level TSP (µg/m3), the fractions PM 10(µg/m3), PM 2.5(µg/m3), PM1(µg/m3), as well as the total number of particles TC (1/l), were shown. It was noted that TSP is approximately at the same level both indoors and outdoors, but the fractions of PM10, PM2.5, and PM1 have much higher values indoors than outdoors with possible consequences on workers' health.The next step was the collection of fibers, namely micro and nano plastic particles from the vicinity of the workplaces of polyester, polyamide, and polypropylene fibers processing units in the textile industry in Romania, to obtain a sufficient quantity for laboratory analysis to determine the size and shape of the particles as well as their chemical composition. Two types of pumps were used, differentiated by their operating parameters: TECORA SKYPOST with airflow of 38 l/min and GILAIRPLUS with airflow 2l/min. Filters made of different materials with different diameters and pore sizes were used, namely: quartz filters (ø 47 mm, and ø 37 mm) on a TECORA SKYPOST type pump, polycarbonate nucleopore coated with a gold membrane (ø 25 mm) and silica filter (ø 9 mm) on GILAIRPLUS type pump.Using descriptive statistics, the calculation of correlation coefficients highlighted a strong correlation between the variables: "Collected mass/ Air concentration" and "Collected mass/ Air volume" for all diameters of the filters.The highest collected particle volume, determined by weighing the filters before and after collection, was obtained with the quartz filters (ø 47 mm) at an airflow of 38 l/min. The particles collected (polyester, polyamide, polypropylene) in the first stage were analyzed by SEM and thermogravimetric and it was found that the quartz filters absorbed the particles inside, with very few remaining on the surface. Thus no known methods can be used to perform analysis for particles collected on quartz filters. The number of particles on the filters was insufficient for analysis either because of the collection parameters used or because of the loss of particles during transport. As a result, in the next step, the use of 9 mm Si filters using the GILAIRPLUS pump at an airflow rate of 2l/min was chosen.To improve the transport conditions and avoid the loss of the particles and keep them on the surface of the filters, two methods were applied:- after weighing the filters were reintroduced into the collection pump holder;- a filtration system for airborne micro-nano plastics was designed and manufactured to selectively collect and transport PM10 and PM1 particles collected on SI filters.In both cases, SEM, Raman mapping, and GS-MS microscopy were used for analysis.Several times more PM10 than PM1 (74.5µg compared to 12.5 µg) was found. In all cases, both particles and fibers showed the same Raman fingerprint.The GS-MS analyses showed some contamination of the workspaces with particles other than the processed fibers. The presence of non-notifiable substances was also observed.The most viable filters are Si filters with a pore size of 10 microns to 1 micron and the use of the selected collection and transport filter system. In the following a filter system will be applied for collection on Au membrane-coated polycarbonate filters. T2 - 5th International Conference on Human Systems Engineering and Design: Future Trends and Applications (IHSED 2023) KW - Microplastics KW - Textiles PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-624442 DO - https://doi.org/10.54941/ahfe1004132 VL - 112 SP - 212 EP - 223 PB - AHFE International AN - OPUS4-62444 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Braun, U. A1 - Herper, D. A1 - Knefel, M. A1 - Bednarz, M. A1 - Bannick, C.-G. T1 - Smart filters for the analysis of microplastic in beverages filled in plastic bottles N2 - The occurrence of microplastic (MP) in food products, such as beverages in plastic bottles, is of high public concern. Existing analytical methods focus on the determination of particle numbers, requiring elaborate sampling tools, laboratory infrastructure and generally time-consuming imaging detection methods. A comprehensive routine analysis of MP in food products is still not possible. In the present work, we present the development of a smart filter crucible as sampling and detection tool. After filtration and drying of the filtered-off solids, a direct determination of the MP mass content from the crucible sample can be done by thermal extraction desorption gas chromatography mass spectroscopy (TED-GC/MS). The new filter crucible allows a filtration of MP down to particle sizes of 5 µm. We determined MP contents below 0.01 µg/L up to 2 µg/L, depending on beverages bottle type. This may be directly related to the bottle type, especially the quality of the plastic material of the screw cap. Dependent on the plastic material, particle formation increases due to opening and closing operations during the use phase. However, we have also found that some individual determinations of samples were subjected to high errors due to random events. A conclusive quantitative evaluation of the products is therefore not possible at present. KW - Microplastic KW - TED-GC/MS KW - Plastic bottles KW - Bbeverages KW - Filter crucible PY - 2021 DO - https://doi.org/10.1080/19440049.2021.1889042 SN - 1944-0057 VL - 38 IS - 4 SP - 691 EP - 700 PB - Taylor & Francis AN - OPUS4-52323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Repräsentative Untersuchungsstrategien für ein integratives Systemverständnis von spezifischen Einträgen von Kunststoffen in die Umwelt (RUSEKU) N2 - Der Vortrag wurde im Rahmen der Abschlusskonferenz des Forschungsschwerpunktes "Plastik in der Umwelt" des BMBF gehalten. Er fasst die Ergebnisse des Verbundprojektes RUSEKU zusammen. Es wurde die Herstellung verschiedener Testmaterialien für die Mikroplastik (MP) Analytik beschrieben. Im weiteren geht es um verschiedene Ansätze MP kostengünstig und schnell zu detektieren, z.B. mit Nahinfrarotspektroskopie. Nanoplastik konnte mit der Transmissionselektronenmikroskopie sichtbar gemacht werden. Für die praxisnahe Beprobung von Gewässern wurde die Fraktionierte Filtration entwickelt. Integrale Beprobungen können mit dem Sedimentationskasten erfolgen. Als Beispiele für die Beprobung realer Gewässer wurde das urbane Abwassersystem Kaiserslautern, Getränkewasser und Waschmaschinenwasser gezeigt. T2 - Abschlusskonferenz des Forschungsschwerpunktes "Plastik in der Umwelt" des BMBF CY - Online meeting DA - 20.04.2021 KW - Mikroplastik KW - TED-GC/MS KW - Probennahme KW - RUSEKU PY - 2021 AN - OPUS4-52546 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - BAM activities on microplastics N2 - The presentation is about BAM's activities on the topic of microplastics. It describes what BAM has done in this field in recent years. On the one hand, TED-GC/MS is presented as an analytical method, on the other hand, currently available microplastic reference materials are presented. T2 - JRC/BAM Workshop on ILC CY - Online meeting DA - 11.02.2021 KW - Microplastic KW - TED-GC/MS KW - Microplastic particles KW - Reference materials PY - 2021 AN - OPUS4-52120 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Microplastics at BAM: TED-GC/MS and reference materials N2 - Thsi talk aims to present the activities of microplastic analysis at BAM according to TED-GC/MS and reference materials developement. T2 - Webinar BAM / University of Birmingham CY - Online meeting DA - 15.06.2021 KW - Microplastic KW - TED-GC/MS KW - Reference materials PY - 2021 AN - OPUS4-53738 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Fast quantitative detection of microplastics using TED-GC/MS, an innovative thermoanalytical method N2 - Im Vortrag wird die BAM vorgestellt und die Motivation für Engagement im Feld der Mikroplastikanalysen dargelegt. Die Herausforderungen bei der Analyse werden aufgezeigt und der Umgang mit ihnen. Das Arbeitsprinzip der TED-GC/MS sowie Leistungsparameter werden erläutert sowie das Vorgehen zur Identifikation und Quantifizierung von Polymeren in er Umwelt. An ausgewählten Beispielen werden interessante Ergebnisse präsentiert und die Mikroplastikreferenzmaterialien der BAM vorgestellt. N2 - In the talk, the BAM is introduced and the motivation for our engagement in the field of microplastic analysis is explained. The challenges in the analysis of microplastics are shown and how we deal with them. The working principle of TED-GC/MS and its performance parameters are presented, as well as the procedure for identifying and quantifying polymers in environmental samples. Interesting results are shown using selected examples. Finally, BAM's microplastic reference materials are highlighted. T2 - National Environmental Monitoring Conference CY - Online meeting DA - 02.08.2021 KW - Microplastic KW - TED-GC/MS KW - Environmental analysis PY - 2021 AN - OPUS4-53081 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik – Ein Problem für die Menschheit? N2 - Mikroplastik findet sich in Ozeanen, Seen, Flüssen und Bächen. Es kann in unserem Boden, in der Luft und sogar in Organismen nachgewiesen werden. Jedes Jahr werden weltweit Millionen Tonnen freigesetzt. Doch wo und wie landet Mikroplastik in der Umwelt? Und wie können wir diese winzigen Partikel nachweisen? T2 - Berlin Science Week CY - Berlin, Germany DA - 01.11.2021 KW - Mikroplastik KW - TED-GC/MS PY - 2021 AN - OPUS4-53734 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna A1 - Braun, U. T1 - Monitoring von Mikroplastik N2 - Der Vortrag gibt einen Überblick was bei der Analyse von Mikroplastik zu beachten ist und beschreibt die Vor- und Nachteile der TED-GC/MS. T2 - Abschlusstreffen MikroPlaTas CY - Online meeting DA - 23.06.2021 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik PY - 2021 AN - OPUS4-52916 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - DACHS/MOFs/AutoMOFs_2/Synthesis N2 - The DACHS (Database for Automation, Characterization and Holistic Synthesis) project aims to create completely traceable experimental data, covering syntheses, measurements, analyses, and interpretations. DACHS_MOFs focuses on the synthesis and characterisation of metal-organic frameworks, across multiple, automation-assisted experimental series (AutoMOFs), with the overall goal of producing reproducible MOF samples through tracking of the synthesis parameters. DACHS_MOFs is simultaneously used to test the DACHS principles. This upload contain synthesis data from AutoMOFs_2 in HDF5 format (.h5). Each .h5 file contains detailed information on the chemical, experimenal, and synthesis parameters used during the synthesis of a single AutoMOF sample. KW - Automation KW - Procedure KW - Synthesis KW - Traceability PY - 2024 DO - https://doi.org/10.5281/zenodo.11236074 PB - Zenodo CY - Geneva AN - OPUS4-60611 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - DACHS/MOFs/AutoMOFs_1/Synthesis N2 - The DACHS (Database for Automation, Characterization and Holistic Synthesis) project aims to create completely traceable experimental data, covering syntheses, measurements, analyses, and interpretations. DACHS_MOFs focuses on the synthesis and characterisation of metal-organic frameworks, across multiple, automation-assisted experimental series (AutoMOFs), with the overall goal of producing reproducible MOF samples through tracking of the synthesis parameters. DACHS_MOFs is simultaneously used to test the DACHS principles. This upload contain synthesis data from AutoMOFs_1 in HDF5 format (.h5). Each .h5 file contains detailed information on the chemical, experimenal, and synthesis parameters used during the synthesis of a single AutoMOF sample. KW - Synthesis KW - Automation KW - Traceability KW - Procedure PY - 2024 DO - https://doi.org/10.5281/zenodo.11236031 PB - Zenodo CY - Geneva AN - OPUS4-60243 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob A1 - Moeez, A. A1 - Hörmann, Anja A1 - Breßler, Ingo T1 - Example configurations and test cases for the Python HDF5Translator framework. N2 - This is a set of use examples for the HDF5Translator framework. This framework lets you translate measurement files into a different (e.g. NeXus-compatible) structure, with some optional checks and conversions on the way. For an in-depth look at what it does, there is a blog post here. The use examples provided herein are each accompanied by the measurement data necessary to test and replicate the conversion. The README.md files in each example show the steps necessary to do the conversion for each. We encourage those who have used or adapted one or more of these exampes to create their own conversion, to get in touch with us so we may add your example to the set. KW - Measurement data conversion KW - Data conversion KW - HDF5 KW - NeXus KW - NXsas KW - Framework KW - Python PY - 2024 DO - https://doi.org/10.5281/zenodo.10925971 PB - Zenodo CY - Geneva AN - OPUS4-59796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falqueto, J. B. A1 - Clark, A. H. A1 - Štefančič, A. A1 - Smales, Glen Jacob A1 - Vaz, C. A. F. A1 - Schuler, A. J. A1 - Bocchi, N. A1 - Kazzi, M. E. T1 - High performance doped Li-rich Li1+xMn2–xO4 cathodes nanoparticles synthesized by facile, fast, and efficient microwave-assisted hydrothermal route N2 - Li-rich nanoparticles of Li1+xMn2–xO4 doped with Al, Co, or Ni are successfully synthesized using a facile, fast, and efficient microwave-assisted hydrothermal route. Synchrotron X-ray diffraction confirms the formation of the crystalline cubic spinel phase type. X-ray absorption spectroscopy analysis at the Co and Ni K- and L-edges verifies that the dopants are within the Li1+xMn2–xO4 spinel structure and are inactive during cycling in the bulk and at the surface. Moreover, we demonstrate that nanocrystallinity and cationic doping play an important role in improving the electrochemical performance with respect to LiMn2O4 microparticles. They significantly reduce the charge-transfer resistance, lower the first cycle irreversible capacity loss to 6%, and achieve a capacity retention between 85 and 90% after 380 cycles, with excellent Coulombic efficiency close to 99% without compromising the specific charge at a 5C cycling rate. Furthermore, the Mn K- and L-edges attest that after long cycling, the Mn oxidation state in the bulk differs from that at the surface caused by the Mn disproportion reaction; however, the cationic doping helps mitigate the Mn dissolution with respect to the undoped Li1+xMn2–xO4 nanoparticles, as indicated by inductively coupled plasma atomic emission spectrometry. KW - XAS KW - SAXS KW - Li-ion battery KW - Cathode material KW - Spinel KW - The MOUSE PY - 2022 DO - https://doi.org/10.1021/acsaem.2c00902 SN - 2574-0962 VL - 5 IS - 7 SP - 8357 EP - 8370 PB - ACS Publ. CY - Washington, DC AN - OPUS4-55359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - X-ray scattering for nanostructure quantification, and the quest for the perfect experiment N2 - Measuring an X-ray scattering pattern is relatively easy, but measuring a steady stream of high-quality, useful patterns requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). With the MOUSE, we have combined a comprehensive and highly automated laboratory workflow with a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. This talk will briefly introduce the foundations of X-ray scattering, present the MOUSE project, and will highlight the proven utility of the methodology for materials science. Upgrades to the methodology will also be discussed, as well as possible avenues for transferring this holistic methodology to other instruments T2 - SNI 2022 CY - Berlin, Germany DA - 05.09.2022 KW - Methodology KW - X-ray scattering KW - Laboratory management KW - Instrumentation utilization KW - MOUSE KW - SAXS KW - WAXS KW - Automation PY - 2022 AN - OPUS4-55760 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - PE-Rezyklat Einsatz in Gefahrgutbehältern? N2 - In diesem Vortrag geht es darum zu beschreiben, ob Rezyklat für PE Behälter gefüllt mit Gefahrgut Anwendung finden darf. Kanister aus Neuware und Rezyklat wurden verschiedenen Untersuchungen unterzogen. Es wurde der Feststoff und Leachable getestet. Methoden sind TED-GC/MS und GC-HRMS. Proben der Leachable wurden nach 1 und 4 Wochen genommen und die Peakanzahl vergleichen dargestellt. Als Lösemittel wurden Wasser, Ethanol, EtOAc, Ammoniak und HNO3 verwendet. T2 - Fachaustausch Projekt GeSKAR CY - Dessau, Germany DA - 10.01.2025 KW - Gefahrgutbehälter KW - Rezyklat PY - 2025 AN - OPUS4-62396 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Textile Fibers as Reference Materials for Microplastic Release N2 - Fibers of textile origin are named as high contributor for microplastic pollution in the environment next to e.g. plastics from packaging, tire wear and paints. Small fibers and fragments (microplastics: 1-1000 µm) can be released from textiles by mechanical abrasion during application (e.g. wearing) or washing. To date, the occurrence, transport pathways, and impacts of such small fibers on the environment and human health remain unclear. The European Commission revised the Urban Wastewater Treatment Directive (Directive (EU) 2024/3019) and made monitoring of microplastics mandatory in the next years. Additionally, standards for microplastic detection are developed in the ISO standardization body ISO/TC 147/SC 2 with the documents ISO/DIS 16094-2 and ISO/DIS 16094-3. Detection mainly occurs by thermoanalytical methods for mass or vibrational methods with microscopes for numbers. Such standards and regulatory efforts need validated methods, which themselves need reference materials for validation. Reference materials are well characterized materials that are produced for a specific purpose and are homogeneous and stable within one property of interest. The shape and the composition of the reference particles/fibers will affect the detection, hence it is important to validate the instruments with fibers, if this is the task for monitoring campaigns. This work describes the production of realistic fibers as reference material for microplastic analysis. The individual samples contain of a small number (< 1000) and mass (< 20 µm) of fibres. Homogeneity and stability control occurred by thermogravimetric analysis and µ-Raman. Further characteristics were determined for type, shape and size distribution. T2 - TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Reference materials KW - Microfibers KW - Microfiber release PY - 2025 AN - OPUS4-64620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - PlasticTrace WP1 – Stakeholder Workshop N2 - The talk summarizes the achievments of WP1 of the PlasticTrace project. Microplastic reference materials were developed by producing tablets. Different preparation methods were compared. Characterisation of the tablets was done after filtration with µFTIR, QCL, µRaman, Py-GC/MS and TED-GC/MS after ISO standards ISO 16094-2 and ISO/FDIS 16094-3. Polymer types are polypropylene and polyethylene terephthalate. T2 - Stakeholder Workshop PlasticsTrace CY - Online meeting DA - 09.09.2025 KW - Microplastics KW - Reference materials KW - TED-GC/MS KW - PET PY - 2025 AN - OPUS4-64258 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Putzu, Mara A1 - Barbaresi, Marta A1 - Fadda, Marta A1 - Sacco, Alessio A1 - Piergiovanni, Maurizio A1 - Masino, Matteo A1 - Bianchi, Federica A1 - Altmann, Korinna A1 - Benismail, Nizar A1 - Coïc, Laureen A1 - Fenoglio, Ivana A1 - Mattarozzi, Monica A1 - Rossi, Andrea Mario A1 - Careri, Maria A1 - Giovannozzi, Andrea Mario T1 - Accuracy assessment of a micro-Raman spectroscopy method for small microplastic particles in infant milk formula N2 - The presence of microplastics (MPs) in the food chain is increasingly documented, raising concerns over potential risks to human health. Despite growing efforts, standardized methods for MPs detection in food matrices remain limited. This study presents an interlaboratory comparison (ILC) aimed at assessing the accuracy and comparability of an analytical approach for the identification and quantification of small MPs (5–100 μm) in infant milk powder using μ-Raman spectroscopy and a representative polyethylene terephthalate (PET) reference material (RM). The RM, formulated as water-soluble tablets, was designed to replicate the morphology, size distribution, and polymer composition of environmentally relevant MPs, and was previously assessed for homogeneity and stability for mass fraction and particle numbers. The approach was assessed using two PET RM batches with different MPs particle numbers (high load batch: 1759 ± 141 MPs; low load batch: 160 ± 22 MPs), subjected to an enzymatic–chemical digestion, followed by μ-Raman analysis performed independently in two laboratories with different instruments and operators. Results are reported as absolute particle counts per analyzed sample and demonstrated excellent recovery across all size classes, including the smallest particles (down to 5 μm), with recovery rates ranging from 82 % to 88 %, in good agreement with the RM reference values. The analytical approach proved to be robust, reproducible, and suitable for low-level MPs quantification in complex food matrices, supporting ongoing efforts toward method harmonization and standardization for reliable MPs monitoring in the food sector. KW - Microplastics KW - Milk KW - Raman microspectroscopy PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646239 DO - https://doi.org/10.1016/j.talo.2025.100586 SN - 2666-8319 VL - 12 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-64623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dinter, Adelina-Elisa T1 - Development of a single cell-ICP-ToF-MS-method for multielement analysis of MIC organisms grown on solid steel samples N2 - The latest ICP-MS technology - ICP-ToF (time of flight)-MS – enables the analysis of the multi-element fingerprint of individual cells. The interface between material and environmental analysis thus receives special attention, e.g., when considering corrosion processes. Microbiologically influenced corrosion (MIC) is a highly unpredictable phenomenon due to the influence of the environment, microbial communities involved and the respective electron source. However, the interaction pathway between cells and the metal surface remains unclear. The development of the MIC-specific ICP-ToF-MS analytical method presented here at the single cell level, in combination with the investigation of steel-MIC interactions, contributes significantly to progress in instrumental MIC analysis and will enable clarification of the processes taking place. For this, a MIC-specific staining procedure was developed. It allows the analysis of archaea at a single cell level and provides information about the interaction of the cells with the staining agent which is extremely scarce compared to other well characterized organisms. Additionally, the single cell ICP-ToF-MS is used for the analysis of archaea involved in MIC of steel. Hence, the possible uptake of individual elements from different steel samples is investigated - the information obtained will be used in the future to elucidate underlying mechanisms and develop possible material protection concepts, thus combining modern methods of analytical sciences with materials. T2 - DAAS Doktorandenseminar 2021 CY - Online meeting DA - 20.09.2021 KW - Sc-ICP-ToF-MS KW - Single cell analysis KW - Microbiologically influenced corrosion KW - Archaea PY - 2021 AN - OPUS4-53340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Wessen Problem ist Mikroplastik eigentlich? N2 - In den letzten 20 Jahren ist die Aufmerksamkeit vieler Forschender sowie der Politik und der Bürger selbst auf ein wachsendes Kunststoffproblem unserer Zeit stark gestiegen. Mangelnde Wertstoffkonzepte, Sammelstellen und unbedachtes Einbringen von Kunststoffprodukten in die Umwelt führen dort zu einer Anreicherung. Durch äußere Witterungseinflüsse können diese Produkte degradieren und fraktionieren, so dass heute in allen Teilen der Welt Mikroplastik (1-1000 µm, ISO/TR 21960:2020) unterschiedlicher Polymermaterialien nachgewiesen werden kann. Bei Mikroplastik gilt das Vorsorgeprinzip. Die Partikel können weiter zerfallen in Nanoplastik (< 1 µm, ISO/TR 21960:2020). Ob eine toxikologische Gefährdung von Mikro- oder Nanoplastik ausgeht, wird vielfältig untersucht. Bisher stehen valide Ergebnisse aus. Untersuchungen zur Häufigkeit, dem Transport und möglicher Senken und Eintragspfade muss aber Rechenschafft getragen werden, so dass ein Monitoring von Mikroplastik bereits in der Revision der Trinkwasserrahmen-Richtlinie und der Abwasserrahmen-Richtlinie gefordert wird. Bedenklich ist auch die Verordnung über Mindestanforderungen an die Wasserwiederverwendung (2020/741), in welcher nicht verbindlich gesagt wird, Wasser welcher Reinigungsstufe eines Klärwerks auf die Felder zur Wiederverwendung aufgebracht werden darf. Einer Regulierung über die EU-Plastikstrategie hinaus mit z.B. Verboten für Einwegplastik-Produkte und Rezyklingquoten kann nur entgegengewirkt werden, wenn valide Messmethoden, Referenzmaterialien und Standards existieren, die das tatsächliche Ausmaß von Mikroplastik-Konzentrationen in Luft, Wasser, Boden und Biota zuverlässig und genau aufzeigen. T2 - Technomer CY - Chemnitz, Germany DA - 06.11.2025 KW - Mikroplastik KW - Referenzmaterial KW - TED-GC/MS PY - 2025 AN - OPUS4-64618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Alasonati, E A1 - Bartczak, D A1 - Altmann, Korinna A1 - Giovannozzi, A T1 - Towards Standardised Micro and Nanoplastics Analysis via Interlaboratory Comparisons: First Outlook of the VAMAS TWA 45 P3 Project N2 - This talk is part of the stakeholder workshop of the PlasticTrace project held in September 2025 in Oslo. The presentation shows first results of the VAMAS ILC on nanoplastics. PP nanoparticles were given to the participants. These were asked to measure the mass or particle number or size of the PP nanoplastics. Various techniques such as DLS, FFF, Py-GC/MS, TED-GC/MS, PTA were used. T2 - Stakeholder Workshop PlasticsTrace CY - Online meeting DA - 09.09.2025 KW - Nanoplastics KW - ILC KW - DLS KW - Polypropylene PY - 2025 AN - OPUS4-64714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, Paul T1 - Microanalysis of Airborne Nano/Microplastic Particles in an Textile Industrial Environment N2 - Micro- and nanoplastics (MNPs) are emerging global contaminants, present in air, soil, and water. The textile industry is potentially a major contributor, releasing synthetic particles like polyamide, polyester, and acrylic during production. This study assessed MNP levels outside and inside a textile-processing facility using online air samplers with silicon (Si) and quartz filters. Real-time particle counts (PM0.3–PM10) were obtained via a laser detector. Si filters (9 mm, 10/1 µm pores) and quartz filters (25 mm, 1.2 µm pores, pre-calcined at 800°C) were used for sampling. Custom holders allowed selective sampling for PM10 and PM1 on Si filters. Sampling conditions included a 3-hour collection at 2 L/min (GilAir Plus pump) starting at 7:00 AM (T1) and 2:00 PM (T2), with intermittent ventilation, 23.3 °C average temperature, and 52.5% humidity. Particle weights collected (µg) were: quartz – 4.9E-05 (T1), 5.1E-05 (T2); Si – 3.2E-05 (T1), 5E-06 (T2). Outside particle counts ranged from 3,584 (T1) to 15,165 (T2); inside: 9,901 (T1) to 12,921 (T2). Maximum indoor PM10 and PM0.3 levels were 72/m³ and 71,979/m³, respectively. Particles were analyzed using electron microscopy and µRaman spectroscopy, confirming high concentrations of irregularly shaped PP-based particles (1–5 µm). T2 - 12th TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Airborne particles KW - Raman microspectroscopy PY - 2025 AN - OPUS4-64485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Portela, Raquel A1 - Barbero, Francesco A1 - Breuninger, Esther A1 - Camassa, Laura Maria Azzurra A1 - Velickovic, Tanja Cirkovic A1 - Charitidis, Costas A1 - Costa, Anna A1 - Fadda, Marta A1 - Fengler, Petra A1 - Fenoglio, Ivana A1 - Giovannozzi, Andrea M. A1 - Haugen, Øyvind Pernell A1 - Kainourgios, Panagiotis A1 - von der Kammer, Frank A1 - Kirchner, Markus J. A1 - Lomax-Vogt, Madeleine A1 - Lujic, Tamara A1 - Milczewski, Frank A1 - Moussawi, Mhamad Aly A1 - Ortelli, Simona A1 - Parac-Vogt, Tatjana N. A1 - Potthoff, Annegret A1 - Jimenez Reinosa, Julian J. A1 - Röschter, Sophie A1 - Sacco, Alessio A1 - Wimmer, Lukas A1 - Zanoni, Ilaria A1 - Dailey, Lea Ann T1 - Characterizing nanoplastic suspensions of increasing complexity: inter-laboratory comparison of size measurements using dynamic light scattering N2 - Understanding the potential human health risks associated with micro- and nanoplastic exposure is currently a priority research area. Nanoplastic toxicity studies are complicated by the lack of available, well-characterized test and reference materials. Further, many nanoplastic test materials are inherently more polydisperse and heterogenous in shape compared to polystyrene beads, making accurate and representative size distribution measurements particularly challenging. The aim of this study was to conduct an inter-laboratory comparison of dynamic light scattering measurements, the most commonly used particle sizing method for nanomaterials. Using a published standard operating procedure, size measurements in water and a standardized cell culture medium (CCM) were generated for spherical, carboxy-functionalized polystyrene nanoparticles (PS-COOH; 50 nm; benchmark material), and for increasingly complex in-house produced spherical poly(ethylene terephthalate) (nanoPET) and irregular shaped polypropylene (nanoPP) test materials. The weighted mean of hydrodynamic diameters of PS-COOH dispersed in water (55 ± 5 nm) showed moderate variation between labs (coefficient of variation, CV = 8.2%) and were similar to literature reports. Measurements of nanoPET (82 ± 6 nm) and nanoPP (182 ± 12 nm) in water exhibited similar CV values (nanoPET: 7.3% and nanoPP; 6.8%). Dispersion of PS-COOH and nanoPET in CCM increased the CV to 15.1 and 14.2%, respectively, which is lower than literature reports (CV = 30%). We conclude with a series of practical recommendations for robust size measurements of nanoplastics in both water and complex media highlighting that strict adherence to a standard operating procedure is required to prevent particle agglomeration in CCM KW - Nanoplastics KW - Reference materials KW - Polypropylene PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-644571 DO - https://doi.org/10.1039/d5en00645g SN - 2051-8153 SP - 1 EP - 15 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64457 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna T1 - Reference material BAM-P206 polyethylene terephthalate (powder) N2 - This report contains detailed information on the preparation of the reference material as well as on homogeneity and stability investigations of the property of interest, the equivalent particle diameter, and on the analytical methods to determine the additional properties. The values for particle size distribution are based on the results from laser diffraction measurements of 3 different devices with at least 3 replicate measurements of 4 randomly chosen units of the reference material P206. KW - Microplastic KW - Reference material KW - PET PY - 2023 DO - https://doi.org/10.26272/opus4-59778 SP - 1 EP - 23 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-59778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kittner, Maria A1 - Altmann, Korinna A1 - Hamann, Sven A1 - Weyer, Rüdiger A1 - Kalbe, Ute T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis - Abschlussbericht N2 - Die Europäische Kommission hat 2023 ein Verbot zum bewussten Austrag von Mikroplastik (MP) in die Umwelt beschlossen, das auch für die Verwendung von synthetischen Gummi-Granulaten (v. a. EPDM) in Sportböden gilt. In Deutschland gibt es laut DFB ca. 5100 Kunstrasenplätze. In der EU beläuft sich die Anzahl laut ECHA auf 13,000 Kunstrasen- und 47,000 Bolzplätze, Tendenz steigend. Das Hauptziel des Projektes war es daher, eine Massenbilanz für die Freisetzung von MP zu erstellen, um so eine Schätzung des MP-Austrags pro Kunstrasenplatz und Jahr zu ermöglichen. Dafür werden die MP-Emissionen von drei Kunstrasenszenarien in verschiedenen Zuständen (ungealtert, künstlich gealtert und in Echtzeit gealtert) verglichen: die Vergangenheit (Kunstrasen: fossilbasiert, EPDM-Füllung), die Gegenwart (der in Europa am häufigsten installierte Rasen) und die Zukunft (Rasen mit recycelten Grasfasern, keine synthetische Füllung sondern z.B. Quarzsand oder Korkschrott). Dazu werden fabrikneue Kunststoffrasen und EPDM-Granulat unter Laborbedingungen beschleunigt gealtert, um die Freiland-Beanspruchung eines Kunststoffrasens in circa 15 Jahren abzubilden. Die Verwendung spezieller Mikrofiltertiegel in Lysimeter-Experimenten ermöglicht die Abschätzung der Partikelgrößen des emittierten MP, was eine Grundbedingung für die Bewertung einer potenziellen Gesundheitsgefährdung für Menschen ist. Ergänzend wurden weitere umweltrelevante Schadstoffausträge aus den Kunststoffrasen quantifiziert. KW - Mikroplastik KW - Kunststoffrasen KW - Schadstoffe KW - Bewitterung KW - Lysimeter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633114 DO - https://doi.org/10.26272/opus4-63311 N1 - Das Projekt wurde gefördert vom Bundesinstitut für Bau-, Stadt- und Raumforschung (BBSR) im Auftrag des Bundesministeriums für Wohnen, Stadtentwicklung und Bauwesen (BMWSB) aus Mitteln des Innovationsprogramms Zukunft Bau. Aktenzeichen: FKZ 10.08.18.7-22.02. Projektlaufzeit: 09.2022 bis 03.2025. SP - 1 EP - 75 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-63311 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -