TY - JOUR A1 - Kricheldorf, H. R. A1 - Weidner, Steffen A1 - Scheliga, F. T1 - Synthesis of cyclic polymers and flaws of the Jacobson–Stockmayer theory N2 - Cyclic poly(L-lactide)s were prepared by ring-opening polymerization combined with simultaneous polycondensation (ROPPOC) in bulk at 160 ° with dibutyltin bis(4-cyanophenoxide) as catalyst. It is demonstrated by MALDI TOF mass spectrometry and 1H NMR end group analyses that cycles are formed by endto-end cyclization in addition to “back-biting” transesterification. Formation of high molar mass cyclic poly L-lactide)s by means of several more reactive ROPPOC catalysts presented previously and in new experiments is discussed. These experimental results, together with theoretical arguments, prove that part of the Jacobson–Stockmayer theory is wrong. The critical monomer concentration, above which end-toend cyclization is seemingly impossible, does not exist and reversible like irreversible polycondensations can theoretically proceed up to 100% conversion, so that finally all reaction products will necessarily adopt a cyclic architecture. KW - Polylactide KW - MALDI-TOF MS KW - Cyclization PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-506419 DO - https://doi.org/10.1039/d0py00226g VL - 11 IS - 14 SP - 2595 EP - 2604 PB - Royal Society for Chemistry AN - OPUS4-50641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de O. Primo, J. A1 - Horsth, D.F. A1 - de S. Correa, J. A1 - Das, A. A1 - Bittencourt, C. A1 - Umek, P. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Yusenko, Kirill A1 - Zanetta, C. A1 - Anaissi, F.J. T1 - Synthesis and Characterization of Ag/ZnO Nanoparticles for Bacteria Disinfection in Water N2 - n this study, two green synthesis routes were used for the synthesis of Ag/ZnO nanoparticles, using cassava starch as a simple and low-cost effective fuel and Aloe vera as a reducing and stabilizing agent. The Ag/ZnO nanoparticles were characterized and used for bacterial dis- infection of lake water contaminated with Escherichia coli (E. coli). Characterization indicated the formation of a face-centered cubic structure of metallic silver nanoparticles with no insertion of Ag into the ZnO hexagonal wurtzite structure. Physicochemical and bacteriological analyses described in “Standard Methods for the Examination of Water and Wastewater” were used to evaluate the efficiency of the treatment. In comparison to pure ZnO, the synthesized Ag/ZnO nanoparticles showed high efficiencies against Escherichia coli (E. coli) and general coliforms present in the lake water. These pathogens were absent after treatment using Ag/ZnO nanoparticles. The results indicate that Ag/ZnO nanoparticles synthesized via green chemistry are a promising candidate for the treatment of wastewaters contaminated by bacteria, due to their facile preparation, low-cost synthesis,and disinfection efficiency. KW - Synchrotron KW - BAMline PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-562440 DO - https://doi.org/10.3390/nano12101764 SN - 2079-4991 VL - 12 IS - 10 SP - 1 EP - 18 PB - MDPI CY - Basel AN - OPUS4-56244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Weidner, Steffen T1 - Syntheses of cyclic polylactides and the problem of catenane formation N2 - Cyclic poly(L-lactide)s (PLAs) were prepared in bulk either by ring-expansion polymerization (REP) or by ring-opening polymerization (ROP) with simultaneous polycondensation (ROPPOC). In contrast to REP the latter method involves formation of linear chains and thus, may involve formation of polydisperse catenanes that affect crystallization. The reprecipitated PLAs were annealed at 120 °C and compared with regard to melting temperature (Tm) and melting enthalpy (ΔHm). For similar molar masses the PLAs prepared by REP and ROPPOC had almost identical Tm's and crystallinities. Furthermore, the influence of REP and ROPPOC catalysts on the morphology of the virgin reaction products was compared. KW - MALDI-TOF MS KW - Catenane KW - Polylactide PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625061 DO - https://doi.org/10.1039/d4ra08683j VL - 15 IS - 5 SP - 3686 EP - 3692 PB - RSC AN - OPUS4-62506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Sweetening the (microplastics) pill: PET tablets (1-100µm) as candidate reference material for the validation of microplastics measurement N2 - The lack of validation and standard procedures in microplastics studies has led to the inability to compare and harmonise data from different analytical methods, laboratories and time scales. To monitor and regulate exposure to microplastics in the environment and in food for human health, it is crucial to ensure their comparability and to validate the analytical methods used in microplastics studies. Monitoring microplastics requires complex approaches for accurate determination otherwise it can lead to an over- or underestimation in environmental and food-relevant matrices. Moreover, to support the need of reliable measurement required by the European legislation directive on drinking water (EU 2020/2184) or the revision of the urban waste water directive, which will be finalised in 2024 the production and validation of polymeric reference materials with environmentally relevant concentrations, irregular shapes, defined aging status and different sizes is essential. The production of reference material with acceptable uncertainties in homogeneity need to be balanced, considering the low microplastics concentrations detected in the environment and in food. The aim of the project PLASTICTRACE and of this study, is to propose a “easy-to-use PET tablet ” (PET particle size mainly 1-100 µm) for routine applications as a candidate general reference material for detection methods. Batches of water-soluble matrix containing different concentrations of PET powder were produced. Results of imaging and counting methods (SEM, Laser diffraction), including production´s challenges; together with thermo-analytical methods (TED-GC/MS and Py-GC/MS) and vibrational spectroscopy (µ-Raman and µ-FTIR), will be presented. These data are useful to assess homogeneity and stability of the particles over time according to ISO 33405:2024. In addition, we will show some insights on the application of the PET-tablets in complex matrices, as milk powder and suspended solid from surface water, that could be easily used for routine microplastics analysis. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Reference materials KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Soraya T1 - Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine (TMB) in Amperometric Assays N2 - Electrochemical methods make great promise to meet the demand for user-friendly on-site devices for monitoring important parameters. Food industry often runs own lab procedures, e.g. for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with miniaturized technologies. Enzyme-linked immunosorbent assays, with photometric detection of the horseradish peroxidase (HRP) substrate, 3,3’,5,5’-tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straight-forward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. It was found that screen-printed gold electrodes and a highly acidic pH value (pH 1) are well-suited to perform the electrochemical detection of TMB, due to the reversible character of the redox reaction under these conditions. This set-up provides a good signal stability over several measuring cycles, providing the basis for analysing multiple samples. In contrast to this, for carbon screen-printed electrodes, it was found that the signal response has changed after the electrochemical reaction with TMB at pH 1. At a weakly acidic pH value (pH 4), neither with carbon nor with gold electrodes a reproducible electrochemical detection of TMB could be achieved [1]. Based on these findings we created a smartphone-based, electrochemical, immunomagnetic assay for the detection of ochratoxin A and ergometrine in real samples. Therefore, a competitive assay was performed on magnetic beads using HRP and TMB/H2O2 to generate the signal. Enzymatically oxidized TMB was quantified after addition of H2SO4 by amperometry with screen-printed gold electrodes in a custom-made wall-jet flow cell. The results are in good correlation with the established photometric detection method, providing a solid basis for sensing of further analytes in HRP-based assays using the newly developed miniaturized smartphone-based, electrochemical, immunomagnetic assay. T2 - Electrochemistry 2022 CY - Berlin, Germany DA - 28.09.2022 KW - Cylic Voltammetry KW - Immunoassay KW - TMB KW - Amperometry PY - 2022 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. AN - OPUS4-55876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Meyer, Andreas A1 - Weidner, Steffen A1 - Kricheldorf, Hans R. T1 - Star-shaped poly(l-lactide)s based on pentaerythritol: About crystallization and polycondensation plus disproportionation and ring formation in the solid state N2 - Star-shaped poly( L-lactide)s (s-PLAs), were prepared by ring-opening polymerization of with pentaerythritol and catalyzed by tin(II) 2-ethylhyexanoate (SnOct out in bulk at either 120 ◦ C or 160 ◦ L-lactide (LA) initiated 2 ). Two small series of ROPs were carried C with variation of the LA/initiator ratio. Matrix-assisted laser desorption/ ionization time-of-flight (MALDI-TOF) mass spectra revealed traces of cycles in 120 ◦ C samples only at low initiator/catalyst ratios. In contrast, higher fractions of cycles were detected in samples prepared at 160 C, suggesting a "back-biting" origin. The influence of arm length and thermal history on crystallinity was investigated by differential scanning calorimetry (DSC) and wide-angle x-ray scattering (WAXS). It was shown that annealing increased the melting temperature (T ◦ ◦ m ) and crystallinity. However, annealing at 140 ◦ C for 14 d also caused significant solid-state transesterification. In addition, crystallites composed of s-PLAs with extended arms and, simultaneously, crystallites composed exclusively of extended rings were formed, identified by their typical "sawtooth" pattern in the MALDI mass spectra. Small angle x-ray scattering (SAXS) indicated that the crystal thickness was lower than that of linear PLAs annealed under identical conditions, but increased upon annealing at 140 C. KW - MALDI-TOF MS KW - Polylactide KW - Crystallisation KW - AStar-shaped polymers PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-636832 DO - https://doi.org/10.1016/j.polymer.2025.128709 SN - 0032-3861 VL - 334 SP - 1 EP - 11 PB - Elsevier Ltd. AN - OPUS4-63683 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Standardized Measurements of Surface Functionalities on Nanoparticles - F. Synthesis and characterization of functional nanocomposite materials N2 - Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely and commonly fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage. NP function, their interaction with biological species, and also their environmental fate are largely determined by the surface functionalities of the particles. Reliable, reproducible, and standardized surface characterization methods are therefore vital for quality control of NPs, determination of their applicability, and mandatory to meet increasing concerns regarding their safety. In addition, industry as well as international standardization organizations, regulatory agencies, and policymakers need validated and standardized measurement methods and reference materials. However, methodologies for determining NP surface properties, including the amount, chemical composition, and homogeneity of surface functionalities and coatings are largely non-standardized up until now. Suitable methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques such as traceable quantitative nuclear magnetic resonance (qNMR), as well as X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods. The latter, typically less costly methods are often used by SMEs, e.g., for quality control. To validate methods, establish measurement uncertainties, test reference materials, and produce reference data, international interlaboratory comparisons (ILC) on NP surface functionalization measurements are required to provide well characterized test and reference nanomaterials including benchmark values.[1] These needs are addressed by the current European metrology project SMURFnano, involving 12 partners from different National Metrology Institutes, designated and research institutes, two university groups as well as one large company and one SME producing NPs. This project, as well as first results derived from the development of test and reference materials with a well characterized surface chemistry, and ongoing interlaboratory comparisons, will be presented. T2 - Shift 2025 CY - La Laguna, Tenerife DA - 13.10.2025 KW - Nano KW - Particle KW - Silica KW - Iron oxide KW - Lanthanide KW - Metrology KW - Quality assurance KW - Reference material KW - Surface chemistry KW - Size KW - Shape KW - Particle number concentration KW - Method KW - Optical assay KW - qNMR KW - Validation KW - Potentiometry KW - XPS KW - ILC KW - Standardization PY - 2025 AN - OPUS4-64370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Scholtz, Lena T1 - Standardized Measurements of Surface Functionalities on Nanoparticles N2 - Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely and commonly fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage. NP function, their interaction with biological species, and also their environmental fate are largely determined by the surface functionalities of the particles. Reliable, reproducible, and standardized surface characterization methods are therefore vital for quality control of NPs, determination of their applicability, and mandatory to meet increasing concerns regarding their safety. In addition, industry as well as international standardization organizations, regulatory agencies, and policymakers need validated and standardized measurement methods and reference materials. However, methodologies for determining NP surface properties, including the amount, chemical composition, and homogeneity of surface functionalities and coatings are largely non-standardized up until now. Suitable methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques such as traceable quantitative nuclear magnetic resonance (qNMR), as well as X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods. The latter, typically less costly methods are often used by SMEs, e.g., for quality control. To validate methods, establish measurement uncertainties, test reference materials, and produce reference data, international interlaboratory comparisons (ILC) on NP surface functionalization measurements are required to provide well characterized test and reference nanomaterials including benchmark values.[1] These needs are addressed by the current European metrology project SMURFnano, involving 12 partners from different National Metrology Institutes, designated and research institutes, two university groups as well as one large company and one SME producing NPs. This project, as well as first results derived from the development of test and reference materials with a well characterized surface chemistry, and ongoing interlaboratory comparisons, will be presented. T2 - eMRS - Fall Meeting 2025 CY - Warsaw, Poland DA - 15.09.2025 KW - Nano KW - Particle KW - Silica KW - Polymer KW - Metrology KW - Quality assurance KW - Reference material KW - Surface chemistry KW - Size KW - Shape KW - Particle number concentration KW - Method KW - Optical assay KW - qNMR KW - Validation KW - Potentiometry KW - XPS PY - 2025 AN - OPUS4-64243 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Standardized Measurements of Surface - Functionalities on Nanoparticles N2 - Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, optoelectronics, and information storage. NP function, interaction with biological species, and environmental fate are largely determined by surface functionalities. Reliable, reproducible, and standardized surface characterization methods are therefore vital for quality control of NPs, and mandatory to meet increasing concerns regarding their safety. Also, industry, international standardization organizations, regulatory agencies, and policymakers need validated and standardized measurement methods and reference materials. However, methodologies for determining NP surface properties, including the amount, chemical composition, and homogeneity of surface functionalities and coatings are largely non-standardized. Suitable methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques such as traceable quantitative nuclear magnetic resonance (qNMR) as well as X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods. The latter less costly methods are often used by SMEs, e.g., for quality control. To validate methods, establish measurement uncertainties, test reference materials, and produce reference data, international interlaboratory comparisons (ILC) on NP surface functionalization measurements are required and well characterized test and reference nanomaterials providing benchmark values.[1] These needs are addressed by the recently started European metrology project SMURFnano involving 12 partners from different National Metrology Institutes, designated institutes, and research institutes, two university groups as well as one large company and one SME producing NPs. This project as well as first results derived from the development of test and reference materials with a well characterized surface chemistry and ongoing interlaboratory comparisons will be presented. T2 - eMRS CY - Strasbourg, France DA - 27.05.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Silica KW - Upconversion nanoparticles KW - Optical assay KW - qNMR KW - Surface analysis KW - Ligand KW - Quantification KW - Functional group KW - XPS KW - ToF-SIMS KW - Polymer particle KW - Surface modification KW - Potentiometry KW - Metrology KW - Method KW - Validation KW - ILC PY - 2025 AN - OPUS4-63339 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Giovannozzi, A T1 - Standardization and Harmonization Effort on Microplastics Analysis by Spectroscopic Methods N2 - This talk presents the EU funded project PlasticTrace. It shows the challenges in micro- and nanoplastic reference materials and gives some solutions regarding spectroscipc methods such as Raman or IR microscopy to determine the particle numbers. Materials are prepared by cryo milling to get some powder that is later pressed into tablets. The polymer type used is PET, because that is highly important for drinking water directive of EU commission. T2 - International Conference on Raman Spectroscopy (ICORS) CY - Roma, Italy DA - 28.07.2024 KW - Microplastics KW - Reference materials KW - Polymer 3R PY - 2024 AN - OPUS4-60881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Stakeholder Workshop – Plastictrace WP1 N2 - The talk is about WP1 in the PlasticTrace project funded by Euromat. The projects harmonizes microplastic analysis by developing SOPs and reference materials. WP1 is responsible for material selection and preparation. All particles are homogeneity and stability checked according to ISO guide 35. T2 - Stakeholder workshop of PlasticTrace project CY - Online meeting DA - 14.12.2022 KW - Microplastic KW - Microplastics standardisation KW - Reference materials PY - 2022 AN - OPUS4-56772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Peters, Stefan A1 - Bartling, Stephan A1 - Parlinska-Wojtan, Magdalena A1 - Wotzka, Alexander A1 - de Oliveira Guilherme Buzanich, Ana A1 - Wohlrab, Sebastian A1 - Abdel-Mageed, Ali M. T1 - Stabilization of intermediate Mo oxidation states by Nb doping enhancing methane aromatization on Mo/HZSM-5 catalysts N2 - The dehydroaromatization of methane is a promising process to produce aromatics and ultra-pure hydrogen. Increased yields and stability of Mo/HZSM-5 against irreversible deactivation were achieved via a redox interaction by doping with otherwise inert Nb. KW - General Materials Science KW - Sustainability and the Environment KW - General Chemistry KW - Renewable Energy PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597670 DO - https://doi.org/10.1039/D3TA07532J SN - 2050-7488 SP - 1 EP - 16 PB - Royal Society of Chemistry (RSC) AN - OPUS4-59767 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - SRXRF examples from the BAMline N2 - Synchrotron radiation sources with their unique properties in terms of intensity, polarization and adjustability offer a wide range of possibilities in materials research. A basic introduction about the creation and special properties of synchrotron radiation will be given. Examples of current work at BAMline, the high-energy measuring facility of the Federal Institute for Materials Research and Testing at the synchrotron BESSY, are used to illustrate the possibilities and limitations of existing measuring methods. T2 - Better with Scattering CY - Online meeting DA - 16.03.2020 KW - Synchrotron KW - BAMline KW - XRF PY - 2020 AN - OPUS4-51895 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dalgic, Mete-Sungur A1 - Weidner, Steffen T1 - Solvent-free sample preparation for matrix-assisted laserdesorption/ionization time-of-flight mass spectrometry ofpolymer blends N2 - Solvent-free sample preparation offers some advantages over solvent-based techniques, such as improved accuracy, reproducibility and sensitivity, for matrix-assisted laser desorption/ionization (MALDI) analysis. However, little or no information is available on the application of solvent-free techniques for the MALDI analysis of polymer blends. Solvent-free sample preparation by ball milling was applied with varying sample-to-matrix ratios for MALDI time-of-flight mass spectrometry analysis of various polymers, including polystyrenes, poly(methyl methacrylate)s and poly(ethylene glycol)s. The peak intensity ratios were compared with those obtained after using the conventional dried droplet sample preparation method. In addition, solvent-assisted milling was also applied to improve sample homogeneities. Depending on the sample preparation method used, different peak intensity ratios were found, showing varying degrees of suppression of the signal intensities of higher mass polymers. Ball milling for up to 30 min was required to achieve constant intensity ratios indicating homogeneous mixtures. The use of wet-assisted grinding to improve the homogeneity of the blends was found to be disadvantageous as it caused partial degradation and mass-dependent segregation of the polymers in the vials.The results clearly show that solvent-free sample preparation must be carefully considered when applied to synthetic polymer blends, as it may cause additional problems with regard to homogeneity and stability of the blends. KW - MALDI TOF MS KW - Sample preparation KW - Polymer blends KW - Solvent-free PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-598570 DO - https://doi.org/10.1002/rcm.9756 SN - 0951-4198 VL - 38 IS - 12 SP - 1 EP - 9 PB - Wiley online library AN - OPUS4-59857 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Meyer, A. A1 - Falkenhagen, Jana A1 - Kricheldorf, H. R. T1 - SnOct2-catalyzed and alcohol-initiated ROPs of L-lactide – About the influence of initiators on chemical reactions in the melt and the solid state N2 - SnOct2 (Sn(II) 2-ethylhexanoate) catalyzed ROPs of L-lactide were performed in bulk with eight different alcohols as initiators. The time was varied between 1 h and 24 h for all initiators. For two initiators the temperature was also lowered to 115 ◦C. Even-numbered chains were predominantly formed in all polymerizations at short times, but the rate of transesterification (e.g. even/odd equilibration) and the molecular weight distribution were found to depend significantly on the nature of the initiator. Observed transesterification reactions also continued in solid poly (L-lactide), and with the most active initiator, almost total equilibration was achieved even at 130 ◦C. This means that all chains including those of the crystallites were involved in transesterification reactions proceeding across the flat surfaces of the crystallites. The more or less equilibrated crystalline polylactides were characterized by DSC and SAXS measurements with regard to their melting temperature (Tm), crystallinity and crystal thickness. KW - Polylactide KW - MALDI-TOF MS KW - Crystallization KW - Catalysts KW - SAXS PY - 2021 DO - https://doi.org/10.1016/j.eurpolymj.2021.110508 VL - 153 SP - 110508 PB - Elsevier Ltd. AN - OPUS4-52633 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Braun, U. A1 - Herper, D. A1 - Knefel, M. A1 - Bednarz, M. A1 - Bannick, C.-G. T1 - Smart filters for the analysis of microplastic in beverages filled in plastic bottles N2 - The occurrence of microplastic (MP) in food products, such as beverages in plastic bottles, is of high public concern. Existing analytical methods focus on the determination of particle numbers, requiring elaborate sampling tools, laboratory infrastructure and generally time-consuming imaging detection methods. A comprehensive routine analysis of MP in food products is still not possible. In the present work, we present the development of a smart filter crucible as sampling and detection tool. After filtration and drying of the filtered-off solids, a direct determination of the MP mass content from the crucible sample can be done by thermal extraction desorption gas chromatography mass spectroscopy (TED-GC/MS). The new filter crucible allows a filtration of MP down to particle sizes of 5 µm. We determined MP contents below 0.01 µg/L up to 2 µg/L, depending on beverages bottle type. This may be directly related to the bottle type, especially the quality of the plastic material of the screw cap. Dependent on the plastic material, particle formation increases due to opening and closing operations during the use phase. However, we have also found that some individual determinations of samples were subjected to high errors due to random events. A conclusive quantitative evaluation of the products is therefore not possible at present. KW - Microplastic KW - TED-GC/MS KW - Plastic bottles KW - Bbeverages KW - Filter crucible PY - 2021 DO - https://doi.org/10.1080/19440049.2021.1889042 SN - 1944-0057 VL - 38 IS - 4 SP - 691 EP - 700 PB - Taylor & Francis AN - OPUS4-52323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Small-angle scattering for everyone: How to unlock the power of this ancient technique N2 - The obscure, yet fundamental technique of scattering can unlock essential information on the fine structure of materials. For you, it can help you understand how your batteries charge, how squid backbones work, or how hundreds of small variations in your syntheses affect your samples. As a nondestructive technique, it also measures your materials *in situ* or operando, as you pull it, heat it, electrify it, or align it one way or another. Scattering can be done using light, X-rays, neutrons, and even electrons, giving you the choice on which probe is best for you. The only downside? Scattering will always remain a complicated technique to do right. The technique gives you only one piece of information: the length distribution of density in your sample. How you interpret this (rather abstract) piece of information is up to you and your samples. Unlike microscopy, where the real-space image can be interpreted almost intuitively and artefacts are easier to spot, in scattering you cannot always easily identify artefacts. Therefore, the only way to do scattering experiments correctly is through rigour and care. For those of us with that particular eccentricity, seeing the rigour and care pay off is exhilarating, and opens the door to a life of happiness and excitement. This lecture will introduce scattering (in particular using X-rays and neutrons), what it is, what you can (and cannot) get out of it, and how to approach your scattering experiment. Regarding the experimental section, it will discuss the five parts that make up a successful scattering experiment based on real-life examples: Preparation: which and how you prepare your samples affects what you can get out of the interpretation Measurement: The machine design and your measurement choices dictates the final quality of your data Correction: Obtaining trustworthy scattering curves will greatly improve the speed and quality of your analysis. Analysis: Do you linearize, use generic scattering models, perform classical least-squares fitting, play with Monte-Carlo analysis or transform your data.. Some tips to help you make a choice. Interpretation: what does the analysis of all your samples tell you? Can you fit the puzzle pieces together to form a piece of knowledge? For further information, please feel free to explore the https://lookingatnothing.com/ weblog, the https://youtube.com/drheaddamage video channel, or by asking me in person or by email for specific questions at brian.pauw@bam.de . Some introductory reading can be found in the following papers: Pauw, B. R. (2013): Everything SAXS: small-angle scattering pattern collection and correction. _J. Phys.: Condens. Matter_ 25: 383201. DOI: [10.1088/0953-8984/25/38/383201](http://dx.doi.org/10.1088/0953-8984/25/38/383201) B. R. Pauw, A. J. Smith, T. Snow, N. J. Terrill, A. F. Thünemann, (2017): The modular SAXS data correction sequence for solids and dispersions, _Journal of Applied Crystallography_, 50: 1800–1811, DOI: [10.1107/S1600576717015096](https://doi.org/10.1107/S1600576717015096) G. J. Smales, B. R. Pauw (2021): The MOUSE project: a meticulous approach for obtaining traceable, wide-range X-ray scattering information. _Journal of instrumentation_ 16 (6) P06034. DOI: [10.1088/1748-0221/16/06/P06034](https://doi.org/10.1088/1748-0221/16/06/P06034) T2 - SAS School at the XIX International Small Angle Scattering Conference CY - Taipei, Taiwan DA - 02.11.2024 KW - X-ray scattering KW - Neutron scattering KW - Scattering KW - X-ray KW - Neutron KW - Introduction KW - Methodology PY - 2024 AN - OPUS4-61623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Affinity Extraction KW - Affinity Separation KW - Protein Purification KW - Down Stream Processing KW - Antibody Purification KW - Diagnostic Antibodies KW - Therapeutic Antibodies KW - Automated Purification KW - HPLC KW - FPLC KW - IgG determination KW - Concentration step KW - Monoclonal Antibodies KW - Polyclonal Antibodies KW - Human Plasma KW - Glass Support KW - Borosilicate Glass KW - Monolith KW - Sintered Material KW - Additive Manufacturing KW - Column holder KW - Construction KW - Open Science KW - Citizen Science KW - Protein A KW - Regeneration KW - High-Speed Separations KW - Robustness PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527581 DO - https://doi.org/10.3390/separations8050056 SN - 2297-8739 N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. VL - 8 IS - 5 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-52758 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as new supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 minute. Due to the glass material's excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nanofiltration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Glass KW - Purification KW - Antibodies KW - Solid support KW - HPLC KW - FPLC KW - Separation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529117 DO - https://doi.org/10.20944/preprints202103.0298.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-52911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Weyrauch, Steffen A1 - Reemtsma, Thorsten A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Ruhl, Aki S. A1 - Jekel, Martin T1 - Settling Velocities of Tire and Road Wear Particles: Analyzing Finely Graded Density Fractions of Samples from a Road Simulator and a Highway Tunnel N2 - The terminal settling velocity is considered the most critical parameter determining the transport of tire and road wear particles (TRWP) in aquatic environments. Nonetheless, no respective empirical data has been reported so far. In this study, particle samples from a road simulator and a highway tunnel were investigated with a validated imaging method. Different density and size fractions of both samples were measured separately, acquiring sizes and settling velocities of more than 30,000 individual particles. In addition, tire marker polymers were analyzed for each fraction via thermal extraction desorption-gas chromatography/mass spectrometry. Finally, the acquired particle data was combined according to the fractions’ estimated tire contents in order to deduce detailed probability distributions of particle size and settling velocity for the actual TRWP from both samples. Weighted by TRWP-incorporated tire mass, median diameters of 54 and 44 μm as well as median settling velocities of 0.65 and 0.22 mm/s were found for TRWP from the road simulator and highway tunnel, respectively. This study thus provides the first ever empirical data on TRWP settling velocities in water, which can be highly valuable input for modeling the environmental transport of TRWP and for dimensioning TRWP retention systems. KW - Microplastics KW - TED-GC/MS KW - Sinking velocities KW - Transport PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635449 DO - https://doi.org/10.1021/acs.est.5c04165 SN - 0013-936X VL - 59 IS - 26 SP - 13434 EP - 13446 PB - American Chemical Society (ACS) AN - OPUS4-63544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Zengchao A1 - Nirmalananthan-Budau, Nithiya A1 - Resch-Genger, Ute A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Separation of polystyrene nanoparticles bearing different carboxyl group densities and functional groups quantification with capillary electrophoresis and asymmetrical flow field flow fractionation N2 - Two sets of polystyrene nanoparticles (PSNPs) with comparable core sizes but different carboxyl group densities were made and separated using asymmetric flow field flow fractionation (AF4), capillary electrophoresis (CE), and the off-line hyphenation of both methods. Our results revealed the significant potential of two-dimensional off-line AF4-CE hyphenation to improve the separation and demonstrated for the first time, the applicability of CE to determine the functional group density of nanoparticles (NPs). Compared to the result acquired with conductometric titration, the result obtained with synthesized 100 nm sized PSNPs revealed only a slight deviation of 1.7%. Commercial 100 nm sized PSNPs yielded a deviation of 4.6 %. For 60 nm sized PSNPs, a larger deviation of 10.6 % between both methods was observed, which is attributed to the lower separation resolution. KW - Nanoparticle KW - A4F KW - Capillary electrophoresis KW - Carboxyl group PY - 2020 DO - https://doi.org/10.1016/j.chroma.2020.461392 VL - 1626 SP - 461392 PB - Elsevier B.V. AN - OPUS4-51080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - You, Zengchao T1 - Separation of polysterene nanoparticles with different coatings using 2D off-line coupling of asymmetrical flow field flow fractionation and capillary electrophoresis N2 - The successful off-line coupling of asymmetrical flow field flow fractionation (AF4) and capillary electrophoresis (CE) for Separation of nanoparticles (NPs) with different surface coatings was shown. Two mixtures of polystyrene nanoparticles (PS-NPs) with comparable core sizes (20 nm and 50 nm) but different coatings (no coating/carboxyl-coated) were studied. Separation in either method resulted in non-baseline resolved or non-separated peaks. In contrast, two-dimensional off-line coupling of AF4 and CE resulted in clearly separated regions in their 2 D plots and can obviouly improve separation resolution. T2 - FFF 2020 CY - Wien, Austria DA - 23.02.2020 KW - Capillary electrophoresis KW - Nanoparticle PY - 2020 AN - OPUS4-50487 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Seasonal microplastic concentrations along the rivers Rhine and Danube N2 - Over the last 20 years, many researchers, politicians and citizens have become increasingly aware of the growing plastic problem of our time. A lack of recycling concepts and plastic collection points as well as careless dumping lead to accumulation of plastic products in the environment. Natural weathering can cause these plastics to degrade and fractionate, meaning that microplastics (1 1,000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) of various synthetic polymer materials can now be detected in all parts of the world. Whether microplastics or nanoplastics pose a toxicological hazard is being investigated in a variety of ways. Valid results are still pending. However, the EU precautionary principle applies to micro- and nanoplastics. Monitoring of microplastics is already required in the revision of the Drinking Water and Wastewater Framework Directive. Reliable monitoring of rivers can be carried out by sampling with sedimentation boxes and microplastic detection by using thermal extraction desorption gas chromatography/mass spectrometry (TED-GC/MS) in routine operation (Figure 1). The river Rhine was sampled for microplastic masses at three different sampling locations over a period of one year and in addition the Danube at randomized sampling locations The TED-GC/MS results showed that various synthetic polymers frequently produced in industry, such as polyethylene, polypropylene or polystyrene as well as the tire compound styrene-butadiene rubber were found. The work not only shows a possible workflow for monitoring concepts, but also provides information on environmentally relevant concentrations of microplastics and tire components in surface waters. This in turn is necessary for ecotoxicological studies. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Polymer 3R PY - 2024 AN - OPUS4-61016 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna A1 - Abusafia, A A1 - Bannick, C-G A1 - Braun, U A1 - Crasselt, Claudia A1 - Dittmar, S A1 - Fuchs, M A1 - Gehde, M A1 - Hagendorf, C A1 - Heller, C A1 - Herper, D A1 - Heymann, S A1 - Kerndorff, A A1 - Knefel, M A1 - Jekel, M A1 - Lelonek, M A1 - Lunkenbein, T A1 - Obermaier, N A1 - Manhart, M A1 - Meurer, Maren A1 - Miclea, P-T A1 - Paul, A A1 - Richter, S A1 - Ricking, M A1 - Rohner, C A1 - Ruhl, A A1 - Sakai, Y A1 - Saravia Arzabe, C A1 - Scheid, C A1 - Schmitt, M A1 - Schnarr, M A1 - Schwertfirm, F A1 - Steinmetz, H A1 - Wander, Lukas A1 - Wiesner, Yosri A1 - Zechmeister, L T1 - RUSEKU - Repräsentative Untersuchungsstrategien für ein integratives Systemverständnis von spezifischen Einträgen von Kunststoffen in die Umwelt : Abschlussbericht N2 - Im Verbundprojekt RUSEKU wurde die Probenahme von Wasserproben entscheidend weiterentwickelt. Wichtig ist hierbei zu gewährleisten, dass genügend Merkmalsträger in jeder Probe untersucht werden. Es muss daher eine für den Probenahmeort repräsentative Beprobung hinsichtlich des Wasservolumens in Abhängigkeit der Partikelanzahl gewährleistet sein. Das Hauptaugenmerk lag im vorliegenden Projekt auf einer praxisnahen Beprobungsstrategie. Es wurden verschiedene Konzepte ausprobiert. • Grundsätzlich hat sich gezeigt, dass eine Stichprobe eine Momentaufnahme des MP-Massengehaltes zeigt. Es wird eine hohe Statistik, also eine Vielzahl an Messungen am gleichen Probenahmeort, benötigt, um eine valide Aussage über den MP-Gehalt zu machen. • Es zeigt sich, dass eine integrale Probenahme über mehrere Wochen mit dem SK routinemäßig möglich ist. Die erfassten MP-Massen sind reproduzierbar und robust. • Die DFZ ist für Stichproben geeignet. Partikel < 50 µm werden eventuell unterschätzt • Die fraktionierte Filtration kann für Stich- und Mischproben direkt im Feld genutzt werden. Fraktionen von 10 und 5 µm werden später im Labor Vakuum filtriert. Es erfolgt eine Fraktionierung der Probe mit Siebmaschenweiten von 1000, 500, 100, 50, 10 und 5 µm. • Die fraktionierte Filtration kann auch anschließend an die Beprobung mit dem SK zur Anwendung kommen. Wird die mit dem SK gewonnene Wasserprobe fraktioniert filtriert, kann neben einem MP-Gesamtgehalt auch eine Einschätzung über die Partikelgrößen gewonnen werden. • Für Wässer mit geringen Partikelzahlen wurde ein Messfiltertiegel entwickelt. Dieser hat eine Maschenweite von 6 µm. Seine Anwendung kann mögliche Verluste beim Transferieren vom Probenahmetool zum Messgefäß und mögliche Kontaminationen reduzieren. Die Optimierung der Probenahmestrategie wurde durch Modellversuche und Simulationen unterstützt. Modellversuche zum Sinkverhalten und Simulationen von MP in realen Gewässern verdeutlichten das komplexe Verhalten der Partikel. Es konnte gezeigt werden, dass Partikel ab einer bestimmten Größe (und kleiner) bei genügend starker Turbulenz sich in der Wassersäule unabhängig von ihrer Dichte verhalten und so auch MP mit kleiner Dichte (z.B. PE) in der gesamten Wassersäule zu finden sind. Es konnte mit dem TEM die Existenz von NP gezeigt werden. Ein wesentlicher Aspekt des RUSEKU Projektes war die Beprobung realer Kompartimente. Beprobt wurde neben Oberflächengewässern, das urbane Abwassersystem der Stadt Kaiserslautern, Waschmaschinenabwasser und Flaschenwasser. • In Oberflächengewässern wurde hauptsächlich PE gefunden. Je nach Probe und Gewässer konnten auch PP, PS, PET, PA, SBR und Acrylate nachgewiesen werden. • Im urbanen Abwassersystem der Stadt Kaiserslautern konnte an allen Probenahmestandorten MP nachgewiesen werden. Es wurde hauptsächlich PE, neben geringeren Mengen an PP, PS und SBR gefunden. Nach einem Regenereignis war der SBR Anteil deutlich erhöht. • Die Beprobung eines realen Wäschepostens, bestehend aus T-Shirts und Hemden mit PA/CO oder PES/CO Mischgewebe, zeigte einen PA- und PES-Austrag im Waschwasser. Der überwiegende Teil der detektierten Fasern ist aber auf Baumwolle zurückzuführen. Reine gravimetrische Messungen zur Detektion von MP führen zu einer starken Überschätzung. • In Flaschenwasser (PET-Flaschen) konnte MP detektiert werden. PET wurde nur im stillen Mineralwasser, nicht in Mineralwasser mit Kohlensäure gefunden werden. Teilweise wurde auch das MP-Material des Verschlusses im Wasser detektiert. • Für Luftproben konnte ein Aufbau zur größenselektiven Beprobung getestet werden. Neben der Probenahme hat das Projekt auch gezeigt, dass die TED-GC/MS geeignet für die MP-Detektion im Routinebetrieb ist. Die TED-GC/MS konnte weiter optimiert werden. Es wurden MP-Massen bestimmt. Im Projekt wurden erste realitätsnahe Referenzmaterialien für die MP Detektion hergestellt. Die Herstellung von realitätsnahen Polymeren in ausreichender Homogenität und Menge hat sich als große Herausforderung herausgestellt. KW - Mikroplastik KW - Probennahme KW - TED-GC/MS KW - Fraktionierte Filtration KW - Mikroplastikreferenzmaterial PY - 2022 SP - 1 EP - 201 AN - OPUS4-57800 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Falkenhagen, Jana A1 - Beskers, Timo. F. A1 - Myxa, Anett A1 - Pursch, Matthias T1 - Round-robin test for size exclusion chromatography – Data summary N2 - Size exclusion chromatography (SEC or GPC) is one critical component of polymer analysis to meet the increasing requirements in regulatory context – namely, determination of Mn, as well as oligomers of less than 500 g mol-1 and 1000 g mol-1. The underlying test methods (OECD 118/119 and DIN EN ISO 13885 1 to 3) provide a framework for SEC measurements; however, they lack sufficient specificity to obtain accurate results. Previous SEC round robin tests were mostly performed on homopolymers and did not collect data on oligomer contents. A new round robin test was initiated and conceptualized within the Task force “Method Evaluation for Polymer REACh (MeEP)”, an initiative of “Industrieforum Analytik” within the German Chemical Society (GDCh). Samples for this study were selected to represent both easy benchmark polymers as well as real-life, industry-relevant polymer materials. Data collection focused on the regulatory requirements. Distribution of samples, gathering of individual results and evaluation were carried out by BAM. A data summary as initial result is reported here. Further evaluation and interpretation are a part of ongoing research. KW - Size exclusion chromatography KW - Polymers KW - Oligomer content KW - Round-robin test PY - 2026 DO - https://doi.org/10.26272/opus4-65587 SP - 1 EP - 84 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-65587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kricheldorf, H. R. T1 - Reversible Polycondensations and the Jacobson-Stockmayer Theory N2 - Reversible polycondensations are polycondensations that include equilibration reactions at any stage of the process. Syntheses of Polyesters in bulk involving transesterification reactions and syntheses of polyamides in bulk involving transamidation are typical examples. In 1950, Jacobson and Stockmayer published a first theory of reversible polycondensations based on experimental studies with aliphatic polyesters.[1,2] They explained the reversibility by the reversible formation of cyclic oligomers and low molar mass polymers from an active chain end (so-called “back-biting”). The formation of cycles via end-to-end cyclization was excluded in agreement with Flory´s theory of irreversible polycondensations.[3] The reinvestigation of the Jacobson-Stockmayer experiments by the authors in combination with theoretical considerations shows that the JS theory is wrong. [4,5] It turned out that the experimental scenario is far from the reality. In real polycondensations, intermolecular equilibration is faster than “back-biting”, and end-to-end cyclization is quite normal. The revised theory of step-growth polymerization predicts that in the ideal case of 100% conversion, all reaction products are cycles, regardless, of whether the step-growth polymerization is reversible or not. T2 - Polycondensation 2024 CY - Lyon, France DA - 15.09.2024 KW - Polycondensation KW - Cyclisation KW - MALDI TOF MS PY - 2024 UR - https://polycond-2024.sciencesconf.org/ AN - OPUS4-61070 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reifschneider, O. A1 - Vennemann, A. A1 - Buzanich, Günter A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Hogeback, J A1 - Köppen, C. A1 - Großgarten, M. A1 - Sperling, M. A1 - Wiemann, M. A1 - Karst, U. T1 - Revealing Silver Nanoparticle Uptake by Macrophages Using SR-μXRF and LA-ICP-MS N2 - To better study the impact of nanoparticles on both in vitro and in vivo models, tissue distribution and cellular doses need to be described more closely. Here silver nanoparticles were visualized in alveolar macrophages by means of synchrotron radiation micro X-ray fluorescence spectroscopy (SR-μXRF) with high spatial resolution of 3 × 3 μm2. For the spatial allocation of silver signals to cells and tissue structures, additional elemental labeling was carried out by staining with eosin, which binds to protein and can be detected as bromine signal with SR-μXRF. The method was compatible with immunostaining of macrophage antigens. We found that the silver distribution obtained with SR-μXRF was largely congruent with distribution maps from a subsequent laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) of the same tissue sites. The study shows a predominant, though not exclusive uptake of silver into alveolar macrophages in the rat lung, which can be modeled by a similar uptake in cultured alveolar macrophages. Advantages and limitations of the different strategies for measuring nanoparticle uptake at the single cell level are discussed. KW - Synchrotron KW - BAMline KW - XRF KW - Nanoparticle KW - Macrophagen PY - 2020 DO - https://doi.org/10.1021/acs.chemrestox.9b00507 VL - 33 IS - 5 SP - 1250 EP - 1255 PB - American Chemical Society AN - OPUS4-50855 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Results of the Plastic in the environment comparative test N2 - The talk describes the sturcture and the results of the "plastics in the environment" comparative test of 2019. T2 - Symposium "Challenges of microplastic analysis – Bridging state of the art and policy needs” CY - Online meeting DA - 09.09.2021 KW - Microplastic KW - Comparative test KW - ILC PY - 2021 AN - OPUS4-53236 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Repräsentative Untersuchungsstrategien für ein integratives Systemverständnis von spezifischen Einträgen von Kunststoffen in die Umwelt (RUSEKU) N2 - Der Vortrag wurde im Rahmen der Abschlusskonferenz des Forschungsschwerpunktes "Plastik in der Umwelt" des BMBF gehalten. Er fasst die Ergebnisse des Verbundprojektes RUSEKU zusammen. Es wurde die Herstellung verschiedener Testmaterialien für die Mikroplastik (MP) Analytik beschrieben. Im weiteren geht es um verschiedene Ansätze MP kostengünstig und schnell zu detektieren, z.B. mit Nahinfrarotspektroskopie. Nanoplastik konnte mit der Transmissionselektronenmikroskopie sichtbar gemacht werden. Für die praxisnahe Beprobung von Gewässern wurde die Fraktionierte Filtration entwickelt. Integrale Beprobungen können mit dem Sedimentationskasten erfolgen. Als Beispiele für die Beprobung realer Gewässer wurde das urbane Abwassersystem Kaiserslautern, Getränkewasser und Waschmaschinenwasser gezeigt. T2 - Abschlusskonferenz des Forschungsschwerpunktes "Plastik in der Umwelt" des BMBF CY - Online meeting DA - 20.04.2021 KW - Mikroplastik KW - TED-GC/MS KW - Probennahme KW - RUSEKU PY - 2021 AN - OPUS4-52546 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eisentraut, Paul A1 - Altmann, Korinna T1 - Repräsentative Mikroplastik-Detektion in Umweltproben - Weiterentwicklung der TED-GC/MS N2 - Die große Herausforderung in der Detektion von Mikroplastik (MP)‑Partikeln (1-1000 µm) besteht darin, sie neben Millionen von natürlichen Partikeln in Umweltproben nachzuweisen. Zum Aufspüren von Senken, Eintragspfaden und für Monitoring-Kampagnen ist ein schnelles, automatisiertes Verfahren unerlässlich. Ein solches Verfahren wurde an der Bundesanstalt für Materialforschung und -prüfung (BAM) mit der ThermoExtraktion/Desorption-Gaschromatographie-Massenspektrometrie (TED-GC/MS) in den letzten Jahren entwickelt. KW - Mikroplastik KW - TED-GC/MS PY - 2021 UR - https://analyticalscience.wiley.com/do/10.1002/was.0004000195 SN - 0016-3538 SP - 2 EP - 5 PB - Wiley-VCH CY - Weinheim AN - OPUS4-54266 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Béalu, Zoé A1 - Walther, Johanna A1 - Abusafia, Attaallah A1 - Altmann, Korinna A1 - Meurer, Maren A1 - Gretzschel, Oliver A1 - Schäfer, Michael A1 - Steinmetz, Heidrun T1 - Removal of Organic Micropollutants and Microplastics via Ozonation Followed by Granular Activated Carbon Filtration N2 - Discharge from Wastewater Treatment Plants (WWTPs) can result in the emission of organic micropollutants (OMPs) and microplastics (MPs) into the aquatic environment. To prevent this harmful release, a pilot plant consisting of an ozonation followed by a granular activated carbon (GAC) filter was operated at a WWTP in Germany, and its side-effects on the concentrations of nitrogen (N) and phosphorous (P) compounds were measured. Over 80% of OMPs and transformation products were removed during the operating time (around 6000 bed volumes) no matter the ozone dose (from around 0.1 to 0.5 mgO3/mgDOC), except for Diatrizoic acid, whose breakthrough appeared at 3500 BV. Formation of the oxidation by-product, NDMA, increased with higher ozone doses, but the concentration remained below 100 ng/L. Bromate was formed at a higher ozone dose (0.4 mgO3/mgDOC) but at a low concentration—below 10 µg/L. The MP particles detected in the inflow (PE, SBR, PP, and PS) were effectively eliminated to a high degree, with a removal rate of at least 92%. Carbon parameters (COD, DOC, and SAC254) were removed further by the pilot plant, but to different extents. As expected, nitrate was formed during ozonation, while nitrite’s concentration decreased. Further, nitrite decreased and nitrate increased within the GAC filter, while ammonium was eliminated by at least 90%. Total P concentration decreased after the pilot, but the concentration of PO4-P increased. KW - Microplastics KW - TED-GC/MS KW - Granular Activated Carbon Filtration KW - Removal of Organic Micropollutants KW - Wastewater treatment plant PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615209 DO - https://doi.org/10.3390/environments11110241 VL - 11 IS - 11 SP - 1 EP - 38 PB - MDPI AG AN - OPUS4-61520 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - Reference Materials at BAM N2 - A introduction into reference materials, the certification process and brief over current reference projects at BAM is given. T2 - AK-Postdoc seminar CY - BAM Berlin, Germany DA - 02.02.2021 KW - Referenzmaterialien KW - Reference material KW - Homogeneity KW - Stability KW - Quality testing KW - Analytic KW - DNA KW - Dosimetry KW - Certification PY - 2021 AN - OPUS4-52060 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Reference material candidates for microplastic analysis N2 - Every day, there are new headlines in the media about microplastics (1-1000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) findings all over the planet with high variations in particle number and mass. The challenges in analytics are very complex, e.g. representative sampling, non-destructive sample preparation with concentrated particles and homogeneous distribution and true detection. All together lead to lacks in harmonization and results, which are hardly comparable. On the other hand, monitoring of microplastics is mandatory in the future strictly regulated by the EU commission in the Drinking water and Wastewater Framework Directive. One step to accurate and precise results will be the development of suitable reference materials mimicking particles in the environment. BAM developed test materials, which are produced by mixing a small portion of microplastic particles with a water-soluble matrix. After solid phase dilution and homogenisation small portions are pressed into tablets and bottled in glass vials (Figure 1). These tablets are well characterized with particle size distribution and SEM images. Additionally, they are tested as reference material candidate according to homogeneity and stability for particle number with µ-IR and µ-Raman as well as on particle mass with Py-GC/MS and TED-GC/MS after ISO Guide 35. Results are promising. The material passed the homogeneity control. No changes are observed within 6 months of storage. The same tested reference material is finally used in sample preparation experiments, where environmental suspended particular matter from surface water or baby milk powders are spiked with the tablets. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polymer 3R KW - Tablets PY - 2024 AN - OPUS4-61017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna T1 - Reference material BAM-P206 polyethylene terephthalate (powder) N2 - This report contains detailed information on the preparation of the reference material as well as on homogeneity and stability investigations of the property of interest, the equivalent particle diameter, and on the analytical methods to determine the additional properties. The values for particle size distribution are based on the results from laser diffraction measurements of 3 different devices with at least 3 replicate measurements of 4 randomly chosen units of the reference material P206. KW - Microplastic KW - Reference material KW - PET PY - 2023 DO - https://doi.org/10.26272/opus4-59778 SP - 1 EP - 23 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-59778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kulow, Anicó A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Emmerling, Franziska A1 - Hampel, S. A1 - Fittschen, UEA A1 - Streli, C. A1 - Radtke, Martin T1 - Reconstruction for coded aperture full-field x-ray fluorescence imaging N2 - X-ray fluorescence imaging is a well-established tool in materials characterization. In this work, we present the adaption of coded aperture imaging to full-field X-ray fluorescence imaging at the synchrotron. Coded aperture imaging has its origins in astrophysics, and has several advantages: Coded apertures are relatively easy to fabricate, achromatic, allow a high photon throughput, and high angular acceptance. Coded aperture imaging is a two-step-process, consisting of the measurement process and a reconstruction step. Different programs have been written, for the raytracing/forward projection and the reconstruction. Experiments with coded aperture in combination with a Color X-ray Camera and an energy-dispersive area detector, have been conducted at the BAMline. Measured samples were successfully reconstructed, and gave a 9.1-fold increase in count rate compared to a polycapillary optic. KW - Synchrotron KW - BAMline KW - Coded Aperture PY - 2022 SN - 1097-0002 VL - 65 SP - 57 EP - 70 PB - Cambridge University Press CY - Cambridge AN - OPUS4-56350 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Oliveira Guilherme Buzanich, Ana T1 - Recent developments of X-ray absorption spectroscopy as analytical tool for biological and biomedical applications N2 - X-ray absorption spectroscopy (XAS), in its various modalities, has gained exponential attention and applicability in the field of biological and biomedical systems. Particularly in this field, challenges like low concentration of analyte or proneness to radiation damage have certainly settle the basis for further analytical developments, when using X-ray based methods. Low concentration calls for higher sensitivity—by increasing the detection limits (DL); while susceptibility for radiation damage requires shorter measurement times and/or cryogenic sample environment possibilities. This manuscript reviews the latest analytical possibilities that make XAS more and more adequate to investigate biological or biomedical systems in the last 5 years. KW - Biological & biomedical applications KW - TXRF-XAS KW - HERFD-XAS KW - RXES KW - Quick-XAS KW - Dispersive-XAS PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-531206 DO - https://doi.org/10.1002/xrs.3254 SN - 0049-8246 VL - 51 IS - 3 SP - 1 EP - 10 PB - John Wiley & Sons Ltd AN - OPUS4-53120 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Real-life airborne micro- and nano-plastic particles and fibres on a porous membrane filter system from a textile factory suitable for both: vibrational and mass spectrometry N2 - The poster presents an application of Si wafer filter system on indoor air sampling. A textile factory producing PP fibres was sampled. T2 - SETAC Europe 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - Microplastics KW - Polymer 3R KW - Textile fibres KW - Si wafer filter KW - Microplastics sampling PY - 2023 AN - OPUS4-57462 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Rapid sample preparation to detect microplastics in baby milk powder N2 - Microplastics, ubiquitous as it is, could be released into food during production chain, through packaging and by consumer´s use. To determinate human exposure to microplastics is crucial to monitor microplastics in food matrices. The current absence of standard sample preparation procedures to identify and quantify different microplastics according to number and mass have generate time-consuming protocols and lack of comparability among different analytical methods, laboratories and time scales. Monitoring microplastics in complex matrices as food, and in particular in baby milk powder, requires an accurate approach that need to be validate, to ensure the comparability of results. Bottled drinking water or surface waters, for example, can be measured with mass-based methods (TED-GC/MS or Py-GC/MS) directly after filtration. Baby milk powder, instead is more challenging, due to the proteins and fatty acid that clog the filters and contaminate the measuring devices with heavy carry over. In this study, we characterize the baby milk powder by thermogravimetric analysis (TGA) and we tested different treatments for matrix reduction: water, H2O2, citric acids. In particular, the use of citric acid was tested for protein reduction before filtration. Our hypothesis was that citric acid will induce the precipitation of proteins and amino acids, leading to a strong matrix reduction. In fact, this sample pre treatment, allowed us to use a higher intake, necessary for representative quantification. Finally, the milk powder was spiked with reference material tablets containing polyethylene terephthalate (PET). The PET was not degraded by the citric acid and high recovery rate was achieved by TED-GC/MS and Py-GC/MS methods. Considering the simplicity and accessibility of this sample preparation and its robust results, this procedure could be easily proposed as a simple sample preparation approach to monitor microplastics by mass-based methods. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Milk KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falkenhagen, Jana A1 - Dalgic, Mete-Sungur A1 - Weidner, Steffen T1 - Quantitative MALDI-TOF Mass Spectrometry of Star-Shaped Polylactides Based on Chromatographic Hyphenation N2 - The end groups of three- and four-arm star-shaped polylactides (PLA) with trimethylolpropane and pentaerythritol core structures were functionalized with acetic acid. Reaction products with different degrees of functionalization were analyzed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Additional gradient elution liquid adsorption chromatography (GELAC) measurements were performed to determine the degree of functionalization. This technique enabled clear separation and sufficient quantification of the formed species. These chromatographic data could be used inversely to quantify mass spectrometric results, which are usually biased by the unknown ionization probabilities of different polymer end group structures. Our results showed that, in this particular case, the peak intensity in the MALDITOF mass spectra can be used to semiquantitatively determine the degree of functionalization in incompletely functionalized multiarm PLA. KW - Polylactides KW - MALDI-TOF-MS KW - Gradient elution liquid adsorption chromatography PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625292 DO - https://doi.org/10.1021/jasms.4c00491 SN - 1879-1123 SP - 1 EP - 9 PB - American Chemical Society (ACS) AN - OPUS4-62529 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dalgic, Mete‐Sungur A1 - Kumar, Sourabh A1 - Weidner, Steffen T1 - Quantitative Analysis of Polymers by MALDI‐TOF Mass Spectrometry: Correlation Between Signal Intensity and Arm Number N2 - The signal intensities of linear and star‐shaped poly(L‐lactides) (PLA) and poly (ethylene oxides) (PEO) were compared to determine the influence of the number of arms on the ionization in matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. In this study, a variety of blends were prepared and investigated, including binary and ternary combinations of linear and star‐shaped polymers with similar molecular masses. The focus was on examining their intensity ratios. In equimolar binary PLA blends, polymer stars were observed to exhibit higher intensities than their linear counterparts. This result was supported by experiments with equimolar ternary PLA blends, which clearly demonstrated an intensity dependence on the number of polymer arms. It was observed that four‐arm PLA exhibited higher intensities than three‐arm PLA. A similar trend was observed in investigations involving acetylated polymer end groups, suggesting that differences in ionization are primarily influenced by polymer architecture rather than end groups. In order to validate this assumption, the binding energies for [polymer‐K] + adduct ions utilizing the most stable geometry obtained from GOAT (Global Optimizer Algorithm) were calculated, revealing that star‐shaped lower mass oligomers have slightly higher binding energies. KW - MALDI-TOF MS KW - Starlike polymers KW - Quantification KW - Topology PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653401 DO - https://doi.org/10.1002/jms.70023 SN - 1076-5174 VL - 61 IS - 1 SP - 1 EP - 12 PB - John Wiley & Sons Ltd. AN - OPUS4-65340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Förste, F. A1 - Bauer, L. A1 - Streeck, C. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Kadow, D. A1 - Keil, C. A1 - Mantouvalou, I. T1 - Quantitative Analysis and 2D/3D Elemental Imaging of Cocoa Beans Using X‑ray Fluorescence Techniques N2 - As an important raw material for the confectionery industry, the cocoa bean (Theobroma cacao L.) has to meet certain legal requirements in terms of food safety and maximum contaminant levels in order to enter the cocoa market. Understanding the enrichment and distribution of essential minerals but also toxic metals is of utmost importance for improving the nutritional quality of this economically important raw food material. We present three X-ray fluorescence (XRF) techniques for elemental bio-imaging of intact cocoa beans and one additional XRF technique for quantitative analysis of cocoa pellets. The interrelation of all the methods presented gives a detailed picture of the content and 3D-resolved distribution of elements in complete cocoa beans for the first time. KW - BAMline KW - Synchrotron KW - XRF KW - CXC KW - Cocoa PY - 2023 DO - https://doi.org/10.1021/acs.analchem.2c05370 VL - 95 SP - 5627 EP - 5635 PB - ACS Publications AN - OPUS4-57832 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantifying the total and accessible amount of surface functionalities and ligands on nano-materials: Overview and recommended methods N2 - Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage. NP function, interaction with biological species, and environmental fate are largely determined by surface functionalities. This calls for reliable, reproducible, and standardized surface characterization methods, which are vital for quality control of NPs, and mandatory to meet increasing concerns regarding their safety. Validated and standardized workflows for surface analysis are also increasingly requested by industry, international standardization organizations, regulatory agencies, and policymakers. To establish comparable measurements of surface functionalities across different labs and ease instrument performance validation, reference test materials and reference materials of known surface chemistry as well as reference data are needed. In the following, different methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques are presented and discussed regarding method-inherent advantages and limitations. Special emphasis is dedicated to traceable quantitative nuclear magnetic resonance (qNMR), X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods. T2 - LNE Workshop CY - Paris, France DA - 04.11.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Automation KW - Potentiometry KW - Method KW - Validation KW - Optical assay KW - Fluram KW - Fluorescamine KW - qNMR KW - Comparison KW - ILC PY - 2025 AN - OPUS4-64726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tavernaro, Isabella A1 - Rajotte, Isabelle A1 - Thibeault, Marie-Pier A1 - Sander, Philipp C. A1 - Kodra, Oltion A1 - Lopinski, Gregory A1 - Radnik, Jörg A1 - Johnston, Linda J. A1 - Brinkmann, Andreas A1 - Resch-Genger, Ute T1 - Quantifying surface groups on aminated silica nanoparticles of different size, surface chemistry, and porosity with solution NMR, XPS, optical assays, and potentiometric titration N2 - We assessed the quantification of surface amino functional groups (FGs) for a large set of commercial and custom-made aminated silica nanoparticles (SiO2 NPs) with sizes of 20–100 nm, prepared with different sol–gel routes, different amounts of surface amino FGs, and different porosity with four methods providing different, yet connected measurands in a bilateral study of two laboratories, BAM and NRC, with the overall aim to develop standardizable measurements for surface FG quantification. Special emphasis was dedicated to traceable quantitative magnetic resonance spectroscopy (qNMR) performed with dissolved SiO2 NPs. For the cost efficient and automatable screening of the amount of surface amino FGs done in a first step of this study, the optical fluorescamine assay and a potentiometric titration method were utilized by one partner, i.e., BAM, yielding the amount of primary amino FGs accessible for the reaction with a dye precursor and the total amount of (de)protonatable FGs. These measurements, which give estimates of the minimum and maximum number of surface amino FGs, laid the basis for quantifying the amount of amino silane molecules with chemo-selective qNMR with stepwise fine-tuned workflows, involving centrifugation, drying, weighting, dissolution, measurement, and data evaluation steps jointly performed by BAM and NRC. Data comparability and relative standard deviations (RSDs) obtained by both labs were used as quality measures for method optimization and as prerequisites to identify method-inherent limitations to be later considered for standardized measurement protocols. Additionally, the nitrogen (N) to silicon (Si) ratio in the near-surface region of the SiO2 NPs was determined by both labs using X-ray photoelectron spectroscopy (XPS), a well established surface sensitive analytical method increasingly utilized for microparticles and nano-objects which is currently also in the focus of international standardization activities. Overall, our results underline the importance of multi-method characterization studies for quantifying FGs on NMs involving at least two expert laboratories for effectively identifying sources of uncertainty, validating analytical methods, and deriving NM structure–property relationships. KW - Advanced Materials KW - Amino Groups KW - Calibration KW - Characterization KW - Functional groups KW - Method Comparison KW - Nano Particle KW - Validation KW - XPS KW - Optical Assay KW - Quantification KW - Surface Analysis KW - Reference Materials KW - Synthesis KW - Fluorescence PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-649992 DO - https://doi.org/10.1039/d5na00794a VL - 7 IS - 21 SP - 6888 EP - 6900 PB - Royal Society of Chemistry AN - OPUS4-64999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Qualitätssicherung bei der Analyse von Mikroplastik per TED GC/MS N2 - Die Thermo Extraktion Desorption Gas Chromatograpie Massen Spektrometrie (TED-GC/MS) ist ein schnelles thermoanalytisches Verfahren zur Bestimmung von Gehalten an Mikroplastik (MP). Die Kombination aus teils schwerflüchtigen Analyten und Kältebrücken führt zu Memory-Effekten, denen u.a. durch häufige Blindwertmessungen begegnet werden muss. Reduzierte Probedurchsätze sind die Folge. Um Messergebnisse abzusichern und den Gerätestatus bei gleichzeitig hoher Messleistung überwachen zu können, wurde die sequentielle Standardmethode überarbeitet. T2 - Tagung der Wasserchemischen Gesellschaft 2022 CY - Online meeting DA - 23.05.2022 KW - Mikroplastik KW - Thermoanalytik KW - TED-GC/MS KW - Qualitätssicherung PY - 2022 AN - OPUS4-55087 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Portesi, C. T1 - qNMR for standardised measurements of surface functionalities on nanoparticles N2 - Engineered nanoparticles have a large application potential in fields such as medicine, sensing, catalysis, energy storage, and opto-electronics [1]. The applicability and performance of engineered nanoparticles is largely determined by their surface chemistry, i.e. functional groups and ligands on the particle surface. However, documented standards to quantify functional groups and ligands currently do not exist. Such standards are required to support quality control of nanomaterial production and surface modification processes, and safe-by-design concepts and to meet regulatory requirements. Here, this issue is addressed by developing and standardizing quantitative Nuclear Magnetic Resonance (qNMR) methods for the characterization of surface functionalized nanoparticles which specifically address the determination of the amount and chemical composition of surface functionalities and coatings. This work is being developed under the EMP project 23NRM02 SMURFnano - Standardised measurements of surface functionalities on nanoparticles. qNMR competence of 7 qNMR laboratories involved in the project was first tested with a molecular model sample i.e. citrate, to be assessed in terms of purity. Citrate is often used as hydrophilic surface ligand for different nanoparticles. Then, the first nanoparticle samples, here a set of aminated SiO2 NPs [1] with a particle size of 100 nm and two amino group densities, prepared and characterized by BAM regarding size and surface charge as well as stability over 21 months with an optical assay and qNMR, were assessed in an international interlaboratory comparison (ILC) on qNMR. Thereby, the amount of surface amino groups introduced by grafting of the silica cores with different amounts of 3-aminopropyl)triethoxysilane (APTES) was quantified by each participant following a sample preparation protocol previously developed by BAM and NRC.The results of the ILC were then used to refine the protocol for sample preparation and to identify critical points for qNMR measurement and data analysis. This work will contribute to the development of a Preliminary Work Item (PWI) 19257 (ISO/TC 229) on surface functional groups and coatings on nano-objects. Also, it will lay the groundwork to perform ILCs on the quantification and determination of the amount of surface functional groups under the roof of VAMAS TWA2 (Surface Chemical Analysis) for different types of nanomaterials possessing industry-relevant surface functionalities using qNMR. These ILCs will be complemented by other techniques like X-Ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). T2 - BERM CY - Halifax, Canada DA - 01.06.2025 KW - Quality assurance KW - Nano KW - Particle KW - Synthesis KW - Advanced materials KW - Characterization KW - Electron microscopy KW - Silica KW - Surface KW - qNMR KW - Optical assay KW - Interlaboratory comparison KW - Metrology KW - Validation KW - Standardization PY - 2025 AN - OPUS4-63443 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Booth, A. T1 - Production of a 1-10 μm polypropylene reference material for development of analytical methods N2 - The poster is about the preparation of microplastics in the size range of 1-10 µm. These size range of particles can be inhalded and therefore be toxic for humans. The preparation is done by comminution of PP pellets and sieving. Characterisation occured for size with laser diffraction, for type with FTIR and for shape with SEM. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials PY - 2025 AN - OPUS4-63367 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rhode, Michael T1 - Processing and application properties of multiple principal element alloys (MPEA) N2 - The presentation gives an overview of BAM's activities on processing influences and application properties of MPEAs in the form of joined and machined high and medium entropy alloys (CoCrFeMnNi and CoCrNi). In the case of welding, the focus is on defect-free welded joints with sufficient mechanical properties. In the case of machining, the focus is on the possible influence on the surface quality of the materials through adequate milling parameters. In addition, the hydrogen absorption and diffusion properties as well as the electrochemical corrosion behavior are fundamentally examined. T2 - FAU-Department Werkstoffwissenschaften, Seminar: Aktuelle Probleme der Werkstoffwissenschaften CY - Erlangen, Germany DA - 25.04.2024 KW - Welding KW - Application properties KW - Machining KW - High-entropy alloy KW - Hydrogen PY - 2024 AN - OPUS4-59975 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Preliminary results of an interlaboratory comparison on microplastics organised by plasticsfate N2 - Microplastics are everywhere in the environment, but analytics is challenging. Since harmonisation is missing as well es suitable reference materials, BAM did under th umbrella of VAMAS funded by the EU Horizon 2020 project PlasticsFate a ILC for microplastic detection methods. Methods adressed were IR, Raman, Py-GC/MS and TED-GC/MS. The talk gives a first presentation and evaluation on the results. T2 - CUSP annual meeting and conference CY - Utrecht, Netherlands DA - 12.09.2023 KW - Microplastics KW - TED-GC/MS KW - Polymer 3R KW - Reference material KW - ILC on detection methods PY - 2023 AN - OPUS4-60036 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Recknagel, Sebastian A1 - Richter, Silke A1 - Hoppe, Marion A1 - Meckelburg, Angela A1 - Prinz, Carsten A1 - Roik, Janina A1 - Abad Andrade, Carlos Enrique T1 - Powering precision: development of a certified reference material for elemental composition analysis of lithium nickel manganese cobalt oxide (Li-NMC) cathode material for lithium-ion batteries N2 - This work presents the development and certification of the world’s first certified reference material (CRM), BAM-S014, for a lithium nickel manganese cobalt oxide (LiNi0.33Mn0.33Co0.33O2 or Li-NMC 111) cathode material—an integral component in high-energy-density lithium-ion batteries that power electric vehicles (EVs), portable electronics, and stationary energy storage systems. By providing certified mass fractions for 11 elements, this CRM addresses a critical need for accurate and traceable elemental analysis, supporting quality control and regulatory compliance in the global battery industry. Ensuring reliable and harmonized measurements supports the efficient use of resources, including the reuse of recycled materials, and ultimately helps maintain product performance and safety. The values were assigned through an interlaboratory comparison involving 16 participating laboratories and various analytical techniques such as inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), X-ray fluorescence (XRF) spectrometry, and combustion analysis. In addition to chemical characterization, the certification process includes homogeneity and stability testing of the candidate material. Details are provided on the analytical methods used for chemical characterization and the calculation of the uncertainties of the certified mass fractions. In addition to detailing the development of the CRMs, this work provides an overview of ongoing standardization activities in Li-component analysis, thereby guiding the calibration of analytical methods and contributing to the establishment of globally accepted standards for evaluating energy storage materials and advancing sustainable mobility and clean energy solutions. KW - Certified reference material KW - Lithium nickel manganese cobalt oxide KW - LNMC KW - Lithium-ion battery KW - Cathode material PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643763 DO - https://doi.org/10.1007/s00216-025-05766-7 SN - 1618-2642 VL - 417 IS - 12 SP - 2643 EP - 2653 PB - Springer Nature AN - OPUS4-64376 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, Hans R. A1 - Weidner, Steffen T1 - Polymerization of L‐Lactide Catalyzed by Metal Acetylacetonate Complexes N2 - ABSTRACTRing‐opening polymerizations (ROPs) of l‐lactide (LA) were performed at 120°C, 140°C, 150°C, and 180°C in bulk catalyzed by acetylacetonate (acac) complexes of manganese(II), nickel(II), copper(II), zirconium(IV), dibutyltin(IV), and vanadyl(V). These experiments revealed that only the acac complexes of Zr and Bu2Sn were reactive enough to enable quantitative polymerization within a few hours. Further ROPs with Bu2Sn(acac)2 and Zr(acac)4 showed that Bu2Sn(acac)2 had a slightly lower reactivity than the Zr complex. The ROPs catalyzed with Zr(acac)4 yielded number average molecular weights (Mn) up to 70,000 g mol−1. The matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectra indicated an exclusive formation of cycles in the mass range of up to m/z 13,000 for Zr(acac)4 and up to m/z 18,000 for Bu2Sn(acac)2. Unusually high melting temperatures (187°C–192°C) were also achieved along with high crystallinities. Furthermore, four lactide/glycolide copolymerizations catalyzed by Zr(acac)4 were performed, and the topology and the extent of transesterification were characterized by MALDI‐TOF mass spectrometry and 13C NMR spectroscopy. KW - MALDI-TOF MS KW - Polycondensation KW - Acetylacetonate PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639754 DO - https://doi.org/10.1002/pol.20250788 SN - 2642-4150 SP - 1 EP - 9 PB - Wiley Periodicals LLC. AN - OPUS4-63975 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -