TY - CONF A1 - Drexel, R. T1 - Nano-sized Polypropylene as a Promising Candidate Reference Material: Preparation, Characterization and Stability in Complex Matrices N2 - The lack of nanoplastic (NPs) reference materials capable of mimicking real-world scenarios is currently hampering the development of validated extraction techniques from complex matrices (e.g. soils, sediments, biota), the development of analytical approaches for robust identification and quantification, and the ability to use environmentally relevant test materials in (eco)toxicity testing and hazard assessment [1]. The large body of available data suggests that larger microplastics (MPs) in the natural environment are irregular shaped, partially degraded (chemically and physically), a continuum of sizes, shapes and densities, represent a wide range of polymer types, and acts as a reservoir for thousands of plastic chemicals. Although NPs have been described as being neither MPs nor engineered nanoparticles [2], and while direct measurement data of true NP in the environment remain elusive, they are expected to be as equally diverse as MPs [3]. Here, we present a strategy towards the development of a potential NP reference material based on nano-sized polyproplyene particles (nanoPP) developed within the EURAMET-funded PlasticTrace project (https://plastictrace.eu/). The strategy includes the preparation, the physicochemical characterization and the stability assessment of nanoPP in suspension both in its pristine state, but also when spiked into food (mineral water and milk) and environmental matrices (suspended particulate matter collected from the river Elbe ). Collected experimental data suggests nanoPP to be a promising candidate for a NP reference material. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Nanoplastics KW - Reference materials PY - 2025 AN - OPUS4-63382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, C A1 - Wiesner, Yosri A1 - Braun, U A1 - Giovannozi, A A1 - Fadda, M A1 - Putzu, Mara A1 - Lorenzo, S A1 - Moscoso-Pérez, C A1 - Benismail, N A1 - Palma, C A1 - Almeida, J A1 - Mattarozzi, M A1 - Barbaresi, M A1 - Piergiovanni, M A1 - Masino, M A1 - Bianchi, F A1 - Careri, M A1 - v Bavel, B A1 - Maltseva, A A1 - Sillanpää, M A1 - Pröfrock, D A1 - Wippermann, D A1 - Altmann, Korinna T1 - Harmonisation of sample preparation for microplastic analysis: Recovery rates of tablets containing microplastics as reference material for food and environmental matrix N2 - Microplastic are found ubiquitarians in the environment and food products. Up to now, their impact of risks on health and environment is still controversially discussed, but based on the precautionary principle alone, their presence should be monitored and emission should be reduced (see here also the status of existing EU regulations ). The crucial point is not only the reduction of microplastics pollution but also the introduction of legally binding, standardized procedures for their analysis. The limited availability of certified reference material as well as absence of standard operating procedures to identify, characterize and quantify microplastics according to number and mass have generated lack of comparability between different analytical methods and laboratories; but also, the need of time-consuming development of own protocols for each laboratory. Further on, harmonisation and standardisation of microplastics analysis requires specific reference materials that are used to validate the measurement and to ensure the comparability of results. In the first step, we developed tablets of a water-soluble matrix, containing defined numbers of microplastic particles or mass contents. These can be solved in water and can be handled as reference materials in bottled drinking water without additional sample preparation. These samples can be measured, using mass-based methods as thermo-analytical methods like thermal desorption-gas chromatography-mass spectrometry (TED-GC/MS) or pyrolysis–gas chromatography–mass spectrometry (Py-GC/MS) and using umber-based methods as vibrational spectroscopy like Infrared and Raman directly after filtration. The aim of this work was to delevop standard operating procedure to measure microplastics in more complex matrices and to harmonise and compare different detection and characterization methods. In fact, these matrices require different additional treatments to allow a reliable quantification and identification of microplastics. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics PY - 2025 AN - OPUS4-63366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fernández-González, V. T1 - Innovations in Microplastic Measurement: A Pyrolysis Approach for a Polyethylene Terephthalate Reference Material N2 - In the framework of the PlasticTrace project, in which a reference material for PET microplastics will be proposed, a method using pyrolysis and gas chromatography coupled with mass spectrometry detection (Py-GC-MS) is developed to quantify the mass of PET microplastics (10-100 µm) in tablets at two different concentration levels. The overall aim of this project is to develop international metrological capacity that enables the traceable measurement and characterization of SMPs and NPs in environmental and food samples and the production of suitable reference materials, according to the metrological requirements (https://plastictrace.eu/). The proposed method consists of dissolving the tablet containing the PET microplastics in milli-Q water and filtering the solution using a glass microfiber membrane 13 mm filter size, 1.6 µm pore size. After filtering and several washes to ensure complete dissolution of the tablet and recovery of all PET microplastics, the filter is removed, folded, and placed in a capsule of the pyrolyzer for direct Py-GC/MS analysis. Two main markers were selected for PET quantification: vinyl benzoate and benzoic acid, with consistent concentrations found for both at high PET concentrations (≈400 µg) (24% RSD, n=17), but interferences with the matrix and vinyl benzoate were found at low concentrations (≈17 µg PET), with only benzoic acid being valid as a marker in this case (22% RSD, n=10). As an alternative to the quantification of PET microplastics in tablets at low concentrations, derivatization is proposed, for which tetramethylammonium hydroxide solution (TMAH) is added directly into the pyrolysis cap. The PET marker in this case is dimethyl terephthalate, with which good results have also been found (19.6% RSD, n=10 ). The proposed method is robust, simple, with high automation and very little sample handling and treatment, and allows the analysis of PET microplastics (>10 µm) in tablets with excellent accuracy and precision even at very low concentrations. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics KW - GC/MS PY - 2025 AN - OPUS4-63383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Booth, A. T1 - Production of a 1-10 μm polypropylene reference material for development of analytical methods N2 - The poster is about the preparation of microplastics in the size range of 1-10 µm. These size range of particles can be inhalded and therefore be toxic for humans. The preparation is done by comminution of PP pellets and sieving. Characterisation occured for size with laser diffraction, for type with FTIR and for shape with SEM. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials PY - 2025 AN - OPUS4-63367 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Putzu, Mara T1 - Optimization of production process for microplastics reference materials N2 - Microplastics (MP) are defined as plastic particles mainly consisting of polymers in the size range of 1 to 1000 µm. They can be found in a wide range of environmental matrices but also in food products, indicating a potential risk on humans and environment. Plastic debris in the environment or food chain are extremely complex in terms of size, concentration, polymer type, levels of physiochemical degradation and undefined morphologies which makes their isolation and detection in complex matrices challenging. Analytical detection methods and techniques to identify and quantify microplastics in environmental and food matrices are numerous but validated and standardized methods are currently lacking. To close this research gap, reference materials (RMs) and representative sample preparation approaches are urgently needed. Homogeneity and stability are two crucial characteristics for the certification process of the reference materials. For this purpose, we aim to present ways to prepare reference materials containing very low masses of close-to reality plastic particles with broad size distribution (10-100 µm) that are homogeneously distributed in tablet-to-tablet variation and stable over time. Our work is based on the ISO Guide 30:2015 and ISO Guide 35:2017 to fulfil the criteria set in future standards ISO/DIS 16094-2 and ISO/DIS 16094-3. The property of interest will be the mass detected by thermogravimetric analysis (TGA). Furthermore, informative values will be achieved by mass-based technique TED-GC/MS and spectroscopic microscopy techniques, such as µ-FTIR spectroscopy and µ-Raman. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials KW - TED-GC/MS PY - 2025 AN - OPUS4-63386 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Weyrauch, Steffen A1 - Reemtsma, Thorsten A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Ruhl, Aki S. A1 - Jekel, Martin T1 - Settling Velocities of Tire and Road Wear Particles: Analyzing Finely Graded Density Fractions of Samples from a Road Simulator and a Highway Tunnel N2 - The terminal settling velocity is considered the most critical parameter determining the transport of tire and road wear particles (TRWP) in aquatic environments. Nonetheless, no respective empirical data has been reported so far. In this study, particle samples from a road simulator and a highway tunnel were investigated with a validated imaging method. Different density and size fractions of both samples were measured separately, acquiring sizes and settling velocities of more than 30,000 individual particles. In addition, tire marker polymers were analyzed for each fraction via thermal extraction desorption-gas chromatography/mass spectrometry. Finally, the acquired particle data was combined according to the fractions’ estimated tire contents in order to deduce detailed probability distributions of particle size and settling velocity for the actual TRWP from both samples. Weighted by TRWP-incorporated tire mass, median diameters of 54 and 44 μm as well as median settling velocities of 0.65 and 0.22 mm/s were found for TRWP from the road simulator and highway tunnel, respectively. This study thus provides the first ever empirical data on TRWP settling velocities in water, which can be highly valuable input for modeling the environmental transport of TRWP and for dimensioning TRWP retention systems. KW - Microplastics KW - TED-GC/MS KW - Sinking velocities KW - Transport PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635449 DO - https://doi.org/10.1021/acs.est.5c04165 SN - 0013-936X VL - 59 IS - 26 SP - 13434 EP - 13446 PB - American Chemical Society (ACS) AN - OPUS4-63544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rossi, A T1 - Lactose Tablets as Suitable Microplastics Reference Material to Support Validation Studies and Quality Control N2 - One of the main challenges in validating microplastics detection methods is the lack of suitable reference materials that accurately reflect the properties of interest. To bridge this gap, the EU-funded PlasticTrace project has developed water-soluble tablets containing precisely defined amounts of polyethylene terephthalate (PET) particles. Each tablet includes a specific mass (0.2, 18.5, or 400 µg) and particle count (151 or 1764, measured via Raman spectroscopy). Production follows a rigorous solid-phase dilution process, ensuring high reproducibility and quality control. The PET particles used in these tablets have an average size of approximately 40 µm, with a range between 10 and 200 µm, and an irregular, stone-like shape. All measurements align with ISO/TC 147/SC 2 standardization efforts and adhere to ISO/DIS 16094-2 and ISO/DIS 16094-3. To assess tablet homogeneity, the most widely accepted microplastics detection techniques, i.e. µ-FTIR, µ-Raman, Py-GC/MS, and TED-GC/MS, were applied. Different batches were produced, each containing varying particle numbers and masses, reaching the detection limits of the methods used. The results demonstrated excellent consistency between tablets, successfully passing homogeneity tests. Furthermore, no significant changes were observed in the tablets' composition or stability after six months of storage. This innovative reference material represents an important advancement in microplastics analysis, supporting laboratories in meeting EU Commission requirements for the monitoring of microplastics in drinking water and wastewater with greater accuracy and reliability. The production process can be transferred for other plastic particles is this size range. T2 - BERM 16 CY - Halifax, Canada DA - 01.06.2025 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Raman microscopy PY - 2025 AN - OPUS4-63403 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Visileanu, Emilia A1 - Altmann, Korinna A1 - Stepa, Raluca A1 - Haiducu, Maria A1 - Miclea, Paul Tiberiu A1 - Vladu, Alina A1 - Dondea, Felicia A1 - Grosu, Marian Catalin A1 - Scarlat, Razvan T1 - Comparative Analysis of Airborne Particle Concentrations in Textile Industry Environments Throughout the Workday N2 - This paper addresses the growing concern surrounding microplastic pollution, particularly within the textile industry, and the associated potential health risks linked to the inhalation and ingestion of microplastic particles. Microplastics, defined as plastic particles smaller than five millimeters, are increasingly found not only in aquatic environments, but also in soils, air, and food. Although research on the health impacts of microplastics is still emerging, early studies indicate that these particles could contribute to health issues, including oxidative stress, inflammation, and cardiovascular diseases. Notably, individuals with higher concentrations of plastics in arterial plaques are more susceptible to heart attacks and strokes. In the textile industry, synthetic fibers such as polyester, nylon, and acrylic release microplastics into the air during production. The paper discusses a study conducted in a textile company that processes polyester yarns, where airborne microplastic concentrations were measured at various locations throughout the day. Particle sizes ranging from 0.3 nm to 10 nm were analyzed, revealing the presence of polyester polymers in the particulate matter. These findings underscore the widespread nature of microplastic pollution, particularly in industrial settings, and raise concerns about the health risks associated with prolonged exposure to airborne microplastics. While further research is necessary to fully understand the extent of these health impacts, preliminary data suggest a troubling link between microplastic inhalation and cardiovascular conditions. KW - Microplastics KW - Textiles KW - Airborne particles PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635269 DO - https://doi.org/10.3390/microplastics4020034 SN - 2673-8929 VL - 4 IS - 2 SP - 1 EP - 17 PB - MDPI AG AN - OPUS4-63526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P-T T1 - Evaluation of Toxicological Characteristics of Airborne Nano/Microplastic Particles From the Industrial Environment N2 - Micro and nano plastic (MNPs) particles and fibres represent a global scale contamination source with hazard potential. They can be identified all around our environment, even in air, soil and water. One of the major global MNPs polluters is the textile industry, which generates plastic particles (nylon, polyester, polyurethane, polyolefin, acrylic etc.) during the manufacturing processes. The study analyses the level of particle concentration outside a company that processes textile yarns, but also from the proximity of workplaces using an online air samplers with cascade and mono filter holders for silicon (Si) and quartz filters, respectively. A laser detector was used for real- time counting of particles of six size classes (PM0.3-PM10). Silicon (Si) filters with a diameter of 9 mm and pore sizes of 10 µm and 1 µm and quartz filters with a diameter of 25 mm and a pore size of 1.2 µm were used for particle sampling. A special holder was designed and made for selective sampling (PM10 and PM1.0) on Si filters. Quartz filters were pre-calcined (8000C) before collection. Sampling parameters: airflow (GilAir Plus pump) -2 l/m3, collection time -3 hours; starting time 7.00 am (T1)/2.00 pm (T2), intermittent natural ventilation, average temperature and humidity: 23.3 0C, RH: 52.5%. The weight of particles collected (µg) on the quart filters was 4.9E-05 (T1) and 5.1E-05 (T2) and on the Si filters 3,2 E-05(T1) and 5E-06(T2). The total number of the outside particles (PM0,3-PM10) was situated between 3584,58 (T1)-15165,05(T2) and inside 9901(T1) and 12921,61(T2). The highest number of PM 10 particles inside was 72/m3 and of PM0.3 particles 71979/m3. The samples were characterized using electron microscopy and µRaman spectroscopy. All samples showed a high concentration of particles on the filter. Samples show only particles with irregular shapes. The equivalent particle diameter was for PM10: 1-5 µm and PM1<1 µm. The total Ion Chromatogram shows the presence of PET-type polymer and the TED GS-MS analysis shows that the weight of the collected particles is PET. After extracting the particles from the quartz filters, they were tested for evaluation of the cytotoxic potential of preparations on human monocyte-macrophage cell cultures and peripheral lymphocytes. In the first case, the level of cytotoxicity was at the border between non-cytotoxic and cytotoxic and in the second test the result was moderate cytotoxic. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - TED-GC/MS KW - Nanoplastics KW - Raman microscopy PY - 2025 AN - OPUS4-63378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Novel laser pre-structured silicon filters for microplastics analysis N2 - This research presents a novel laser-assisted approach to silicon filter fabrication, offering an effective alternative to traditional photolithographic processes. By integrating selective femtosecond laser irradiation with photoelectrochemical etching, we achieved precisely controlled pore geometries, overcoming common challenges in filter production for microplastic and nanoscale filtration suitable for microplastic number and mass analysis. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics KW - Raman microspectroscopy PY - 2025 AN - OPUS4-63384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hülagü, Deniz A1 - Ermilova, Elena A1 - Weise, Matthias A1 - de Préville, Sophie A1 - Hoffmann, Johannes A1 - Morán-Meza, José A1 - Piquemal, Francois A1 - Hertwig, Andreas T1 - Characterization of electrical properties in microstructured ITO layers using spectroscopic ellipsometry N2 - Thin indium tin oxide (ITO) layers are essential in optoelectronics due to their good electrical conductivity, optical transparency in the visible and near infrared regions, substrate adherence and chemical stability. They are widely used in photovoltaic cells, displays, and organic LEDs, and as low emissivity coatings in smart windows and energy-efficient buildings. For nanophotonic devices, understanding the interplay of ITO’s optical and electrical properties is crucial. Electrical resistivity can be tuned by modifying deposition conditions and layer thickness. However, measuring these properties, especially on microstructured surfaces, remains challenging due to the issues like homogeneity and instability during etching. Spectroscopic ellipsometry (SE), a non-destructive and phase-sensitive optical technique, offers precise measurement of thin film thickness and dielectric properties. In this study, we investigated the layer thickness, optical constants, and sheet resistance of unstructured and microstructured ITO thin layers using SE. Unstructured layers were deposited via DC-magnetron sputtering on silicon (Si) substrates in argon (Ar) atmospheres with varying oxygen (O2) flows. This multi-technique approach enhances the understanding of ITO layer structuring and provides robust methodologies for correlating optical and electrical properties, advancing metrology for nanotechnology applications and material science. It also opens the pathway to new reference samples and calibration methods for electrical properties involving device-like structured samples. T2 - ICSE10 - 10th International Conference on Spectroscopic Ellipsometry CY - Boulder, CO, USA DA - 08.06.2025 KW - Ellipsometry KW - Indium tin oxide (ITO) KW - Scanning microwave microscopy (SMM) KW - Sheet resistance calibration standards KW - ITO wet etching PY - 2025 AN - OPUS4-63631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fink, Friedrich A1 - Stawski, Tomasz M. A1 - Emmerling, Franziska A1 - Falkenhagen, Jana T1 - A novel machine-learning approach to unlock technical lignin classification by NIR spectroscopy - bench to handheld N2 - In this research, the utilization of near-infrared (NIR) spectroscopy in conjunction with advanced machine learning methods is investigated for categorizing technical lignins obtained from different biomass sources and industrial procedures. Technical lignins, such as kraft, organosolv and lignosulfonates, have different chemical compositions, which continue to make uniform characterization and application in sustainable sectors extremely difficult. Fast, universally accessible analytics combined with data analysis is still an open question. For the first time three distinct NIR spectrometers—a high-performance benchtop system, a mid-priced compact device, and an economical handheld unit—were utilized to record NIR spectra of 31 unique lignin samples. The spectra underwent pre-processing through standard normal variate (SNV) transformation and Savitzky-Golay derivatives to amplify spectral features and decrease noise. Principal component analysis (PCA) was employed to reduce data complexity and extract crucial characteristics for classification purposes. Subsequently, four machine learning algorithms—Support Vector Machines (SVM), Gaussian Naive Bayes (GNB), Gaussian Process Classification (GPC), and Decision Tree Classification (DTC)—were implemented for the classification of the lignin samples. The DTC model exhibited the highest accuracy among them across different spectrometers. Although the benchtop spectrometer produced the most precise outcomes, the compact NeoSpectra system also displayed potential as a cost-efficient option. Nonetheless, the restricted spectral coverage of the handheld NIRONE spectrometer resulted in reduced classification accuracy. Our discoveries highlight the capability of NIR spectroscopy, combined with robust data analysis techniques, for the swift and non-destructive classification of technical lignins, facilitating their improved utilization in sustainable fields. KW - Technical lignins KW - NIR spectroscopy KW - Classification KW - Machine-learning KW - PCA PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-634518 DO - https://doi.org/10.1016/j.chemolab.2025.105467 SN - 0169-7439 VL - 264 SP - 1 EP - 10 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-63451 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Goedecke, Caroline A1 - Bannick, C.-G. A1 - Abusafia, A. A1 - Scheid, C. A1 - Steinmetz, H. A1 - Paul, Andrea A1 - Beleites, C. A1 - Braun, U. T1 - Identification of microplastic pathways within a typical European urban wastewater system N2 - In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other. KW - Microplastics KW - Microplastic analysis KW - TED-GC/MS KW - Microplastic pathways KW - Mass contents PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568289 DO - https://doi.org/doi.org/10.1002/appl.202200078 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, U. T1 - Detection of plastics in soil N2 - Soil acts as a final sink for pollutants. Microplastics from different sources such as plastic mulching, littering, compost, sewage sludge, sedimentary deposition, and tyre abrasion are expected to be found in soil. However, representative and comprehensive information is missing on the sources, transport, and fate. Therefore, a reliable analysis method for microplastics in soils needs to be developed. The presented work describes the development of a procedure for microplastics analysis in soils. A representative sampling based on the on-site conditions and a sample preparation method was established and comprised of a drying step, the separation of microplastic particles > 1 mm, and a density separation for particles < 1 mm. The detection of the large microplastic particles (> 1 mm) was conducted with Attenuated Total Reflection - Fourier Transform infrared Spectroscopy (ATR-FTIR) , while Thermal Extraction Desorption - Gas Chromatography / Mass Spectrometry (TED-GC/MS) was applied for particles < 1 mm, gaining information on the type of polymer and mass fraction. Based on the established method, 14 environmental soil samples ? with different exposure of microplastics from agriculture, industrial sites, roads, and floods were investigated. Due to the arbitrary microplastic particle distribution among the samples for large microplastics, it was reasoned that the found particles were unrepresentative. In contrast, microplastic particles < 1 mm were discovered in a high mass in soil samples exposed to plastic mulching or fertilization with sewage sludge or compost (0 – 115 mg/kg). On average, microplastic contents detected in soil samples taken from a construction site and an inner-city lake were higher (13 – 238 mg/kg). As expected, microplastic content in soil sampled in proximity to roads was more pronounced in the upper soil layers. In contrast, very remote sampling sites, expectably uncontaminated, did not lead to the detection of microplastic regarding to thermoanalytical detection method. In a proof of concept experiment several in vivo and in vitro ecotoxicological tests were applied to evaluate the effect of microplastics (tyre abrasion, polystyrene containing hexabromocyclododecane) in natural soils. In summary, while no effects of the examined probes could be detected on higher levels of biological organization after exposures to earthworm E. andrei, significant changes in several oxidative stress related biomarkers were observed. T2 - SETAC Europe 2022 CY - Kopenhagen, Denmark DA - 15.05.2022 KW - Microplastic KW - TED-GC/MS KW - Soil PY - 2022 AN - OPUS4-55872 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Plastik in Böden: Mikroplastik-Ergebnisse N2 - In diesem Vortrag geht um die Vorstellung der Ergebnisse des UBA Projektes Plastik in Böden. Es werden Mikroplastik-Gehalte in verschiedenen Böden präsentiert. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - Mikroplastik Böden KW - Mikroplastik-Analytik PY - 2022 AN - OPUS4-54648 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik an der BAM: TED-GC/MS und Referenzmaterialien N2 - Thema ist die Funktionsweise der TED-GC/MS als Methode für die Mikroplastik-Detektion sowie die Herstellung dazugehöriger Referenzmaterialien an der BAM T2 - 25. Kolloquium Massenspektrometrie von Polymeren CY - Online meeting DA - 17.06.2021 KW - Mikroplastik KW - TED-GC/MS KW - Referenzmaterial PY - 2021 AN - OPUS4-52835 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Linberg, Kevin T1 - Controlled Polymorphism by Elevated Temperature Ball Milling N2 - Mechanochemistry provides polymorphs that are difficult to obtain by conventional solution-based methods. Based on the nicotinamide and pimelic acid cocrystal, we demonstrated that the ball size, frequency, and temperature are essential parameters. Our results indicate that fine-tuning the energy input during a mechanochemical reaction can provide control over polymorphism. T2 - Bessy User Meeting 2023 CY - Berlin, Germany DA - 22.06.2023 KW - Mechanochemistry KW - Temperature KW - Cocrystal KW - Energy input KW - Polymorph PY - 2023 AN - OPUS4-57985 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Reference material candidates for microplastic analysis N2 - Every day, there are new headlines in the media about microplastics (1-1000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) findings all over the planet with high variations in particle number and mass. The challenges in analytics are very complex, e.g. representative sampling, non-destructive sample preparation with concentrated particles and homogeneous distribution and true detection. All together lead to lacks in harmonization and results, which are hardly comparable. On the other hand, monitoring of microplastics is mandatory in the future strictly regulated by the EU commission in the Drinking water and Wastewater Framework Directive. One step to accurate and precise results will be the development of suitable reference materials mimicking particles in the environment. BAM developed test materials, which are produced by mixing a small portion of microplastic particles with a water-soluble matrix. After solid phase dilution and homogenisation small portions are pressed into tablets and bottled in glass vials (Figure 1). These tablets are well characterized with particle size distribution and SEM images. Additionally, they are tested as reference material candidate according to homogeneity and stability for particle number with µ-IR and µ-Raman as well as on particle mass with Py-GC/MS and TED-GC/MS after ISO Guide 35. Results are promising. The material passed the homogeneity control. No changes are observed within 6 months of storage. The same tested reference material is finally used in sample preparation experiments, where environmental suspended particular matter from surface water or baby milk powders are spiked with the tablets. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polymer 3R KW - Tablets PY - 2024 AN - OPUS4-61017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Rapid sample preparation to detect microplastics in baby milk powder N2 - Microplastics, ubiquitous as it is, could be released into food during production chain, through packaging and by consumer´s use. To determinate human exposure to microplastics is crucial to monitor microplastics in food matrices. The current absence of standard sample preparation procedures to identify and quantify different microplastics according to number and mass have generate time-consuming protocols and lack of comparability among different analytical methods, laboratories and time scales. Monitoring microplastics in complex matrices as food, and in particular in baby milk powder, requires an accurate approach that need to be validate, to ensure the comparability of results. Bottled drinking water or surface waters, for example, can be measured with mass-based methods (TED-GC/MS or Py-GC/MS) directly after filtration. Baby milk powder, instead is more challenging, due to the proteins and fatty acid that clog the filters and contaminate the measuring devices with heavy carry over. In this study, we characterize the baby milk powder by thermogravimetric analysis (TGA) and we tested different treatments for matrix reduction: water, H2O2, citric acids. In particular, the use of citric acid was tested for protein reduction before filtration. Our hypothesis was that citric acid will induce the precipitation of proteins and amino acids, leading to a strong matrix reduction. In fact, this sample pre treatment, allowed us to use a higher intake, necessary for representative quantification. Finally, the milk powder was spiked with reference material tablets containing polyethylene terephthalate (PET). The PET was not degraded by the citric acid and high recovery rate was achieved by TED-GC/MS and Py-GC/MS methods. Considering the simplicity and accessibility of this sample preparation and its robust results, this procedure could be easily proposed as a simple sample preparation approach to monitor microplastics by mass-based methods. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Milk KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Plastik in Böden: Mikroplastik-Analytik N2 - Im Vortrag wir eine Methode zur Analyse von Mikroplastik in Böden dargestellt. Es geht dabei um die Probenvorbereitung und Detektion. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik KW - Methodenentwicklung Böden PY - 2022 AN - OPUS4-54646 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -