TY - CONF A1 - Abad Andrade, Carlos Enrique A1 - Winckelmann, Alexander A1 - Hoffmann, Volker A1 - You, Zengchao A1 - Richter, Silke A1 - Recknagel, Sebastian T1 - What does GD-OES reveal about the aging and manufacturing processes of lithium-ion batteries? N2 - Glow-Discharge Optical Emission Spectroscopy (GD-OES), a powerful analytical technique, sheds light on the two critical aspects of lithium-ion batteries (LIBs): manufacturing and aging 1, 2. We optimized cell production in manufacturing by adjusting parameters, including cathode doping, electrolyte concentration, and pressing force. GD-OES provided in-depth elemental composition and homogeneity analysis, which is crucial for identifying optimal manufacturing conditions. These findings were validated by electrochemical impedance spectroscopy, confirming the quality of the manufactured batteries. Shifting the focus to aging, we use GD-OES for fluorine depth profiling, a key element in understanding polymer and electrolyte degradation. However, fluorine presents analytical challenges. We addressed this by substituting argon with a neon:argon mixture, which significantly enhanced fluorine detection sensitivity. This advancement not only improves accuracy but also holds the potential to guide sustainable and cost-efficient manufacturing strategies. Through its versatility, GD-OES has proven to be a powerful tool for not only optimizing LIB manufacturing processes but also gaining deeper insights into their aging mechanisms. This research extends beyond academic interest, offering tangible benefits for the industry by translating into improved battery quality, extended lifespan, and overall performance. T2 - The 6th International Glow Discharge Spectroscopy Symposium CY - Liverpool, United Kingdom DA - 21.04.2024 KW - GD-OES KW - Depth profiles KW - Lithium KW - Battery KW - Fluorine KW - Aging KW - Manufacturing KW - Glow-discharge PY - 2024 AN - OPUS4-59945 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grimmer, Christoph A1 - Strzelczyk, Rebecca A1 - Richter, Matthias A1 - Musyanovych, Anna A1 - Horn, Wolfgang T1 - Development, application and measurement uncertainty of emission reference materials N2 - Volatile organic compounds (VOCs) emitted by furniture and building materials can cause health issues. For an improvement of indoor air quality low emitting materials should be used. Quality assurance and –control (QA/QC) measures require an emission reference material (ERM) with a predictable emission rate of VOCs. The idea is to use porous materials as ERM, which store the VOCs inside their pores and emit them constantly. T2 - Webinar Metrology for Indoor Air Quality Reference materials for QA/QC of the emission test chamber procedure CY - Online meeting DA - 11.04.2024 KW - Emission reference materials KW - Indoor air quality KW - Materials emissions test KW - VOC PY - 2024 AN - OPUS4-59963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lisec, Jan A1 - Jaeger, Carsten T1 - Metabolomics N2 - A 90 minutes overview on metabolomics as an analytical method for life sciences. T2 - IceBio Network training event CY - Grenoble, France DA - 29.02.2024 KW - Mass Spectrometry KW - Metabolomics KW - Data Analyses PY - 2024 AN - OPUS4-59596 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor T1 - Plasma Fundamentals and Diagnostics N2 - This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, micro reactions, pump and probe diagnostics, tomography, temporal and spatial resolution. Basis of plasma computer modeling will be presented. T2 - 2024 Winter Conference on Plasma Spectrochemistry CY - Tucson, Arizona, USA DA - 15.01.2024 KW - Plasma KW - Plasma fundamentals KW - Plasma diagnostics PY - 2024 AN - OPUS4-59430 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor T1 - Laser-Induced Plasma for Spectroscopy and More N2 - An overview of personal experience with laser-induced plasma (LIP) will be given. The combination of LIP with laser-induced fluorescence, atomic absorption, Raman spectroscopy and spatial heterodyne spectroscopy for elemental and isotopic analysis will be discussed. Unusual applications of LIP will be covered, such as LIP-based lasers and LIP-based chemical reactors. T2 - 2024 Winter Conference on Plasma Spectrochemistry CY - Tucson, Arizona, USA DA - 15.01.2024 KW - Laser induced plasma KW - Laser ablation KW - LIP-LIF KW - LIP-AAS PY - 2024 AN - OPUS4-59431 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Grimmer, Christoph A1 - Musyanovych, A. A1 - Strzelczyk, Rebecca Skadi A1 - Horn, Wolfgang T1 - Emission reference materials for indoor air measurements N2 - In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. VOC in combination may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. Emission concentrations can become further elevated in new or refurbished buildings where the rate of air exchange with fresh ambient air may be limited due to improved energy saving aspects. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use (building) materials proved to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable emission reference materials (ERM). For the emission test chamber procedure according to EN 16516, no artificial ERM is commercially available. The EU-funded EMPIR project MetrIAQ aims to fill this gap by developing new and improved ERMs. The goal is to obtain a material with a reproducible and temporally constant compound release (less than 10 % variability over 14 days). Two approaches were tested: the impregnation of porous materials with VOC, and the encapsulation of VOC in polymer microcapsules. Impregnation is performed with help of an autoclave and supercritical CO2. The encapsulation is done by interfacial polymerisation on VOC droplets. For both approaches, synthesis and/or material parameters were varied to obtain an optimal ERM. Findings about the optimisation of ERM generation, as well as performance of the best emission reference materials, will be presented. T2 - GAS Analysis 2024 CY - Paris, France DA - 30.01.2024 KW - Emission reference materials KW - Materials emissions test KW - VOC KW - Indoor air quality PY - 2024 AN - OPUS4-59506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Döring, Sarah A1 - Konthur, Zoltán A1 - Heiner, Zsuzsanna T1 - Optimization of surface-functionalized particles for improved antibody digestion N2 - Therapeutic monoclonal antibodies are the fastest-growing group of biological agents which generated a yearly turnover of USD 210 billion in 2022 and whose sales are expected to grow by 10% annually over the next 10 years. With steadily increasing market importance, analytical methods for reliable quantification of therapeutic antibodies also become more and more relevant. Liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) has become the main technology for antibody quantification. This approach, however, requires enzymatic digestion of the intact protein into peptides, for which a wide range of different protocols exists that often lead to different results depending on the digestion procedure or trypsin variants used. In particular, the amount and type of detergents added for protein unfolding prior to digestion is known to create significant bias in measurement results. The overall goal of the presented project is the application of novel thermostable and surface-functionalized trypsin particles for improved antibody digestion. Specifically, a trypsin-variant described in the literature exhibiting increased activity and thermal stability above 80°C, will be examined. The application of this enzyme should allow to perform digestion at elevated temperatures where the protein is naturally unfolding thereby increasing enzyme accessibility without the need for detergents. Furthermore, we will immobilize the thermostable trypsin onto the surface to further enhance enzyme stability, prevent self-digestion, and enable separation of trypsin from target peptides before LC–MS/MS analysis. As an immobilization platform, cheap and non-porous corundum particles will be used as these show high chemical stability and low levels of interaction of matrix proteins with the functionalized surface. adsorption. In a multidisciplinary collaboration with the SALSA Photonics Lab, we will investigate the characteristics of covalent enzyme binding and unspecific peptide binding using an interface-sensitive analytical tool, vibrational sum-frequency generation (VSFG) spectroscopy. The insights gained will not only lead to new competencies in peptide and enzyme surface analysis using VSFG spectroscopy in SALSA but will also significantly contribute to optimizing antibody quantification. T2 - SALSA STF24 Kick-Off Meeting CY - Berlin, Germany DA - 11.04.2024 KW - Antibody Quantification KW - Vibrational Sum-Frequency Generation Spectroscopy KW - LC-MS/MS KW - Enzyme Immobilisation KW - Corundum PY - 2024 AN - OPUS4-59864 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Winckelmann, Alexander T1 - Taking Chances – Cheese, Chocolate and Laser Spectroscopy N2 - Science Café Adlershof is having its next edition in 2024 on February 20th '24! We will have one speaker next week: Alexander Winckelmann is a PhD student at Bundesanstalt für Materialforschung und -Prüfung and will give a talk about his stay abroad in Switzerland - there will be free chocolates! There will be enough time to ask questions or simply chat with the guests and participants. T2 - Science Café Adlershof CY - Berlin, Germany DA - 20.02.2024 KW - Laser-induced XUV Spectroscopy KW - Multivariate Data Analysis KW - Science Communication PY - 2024 AN - OPUS4-60197 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Winckelmann, Alexander T1 - Advanced spectroscopic methods for fluorine microanalysis in lithium-ion batteries N2 - To address the challenges of the climate crisis, multiple solutions for sustainable energy sources and storage systems are needed. One such solution is lithium-ion batteries (LIBs). Currently, 5 to 30 % of LIBs are discarded immediately after manufacturing. The homogeneous distribution of all materials used in the coating of cathodes and anodes is critical for the quality of LIBs. Furthermore, during formation i.e., the first steps of the charge/discharge cycling, the solid-electrolyte interphase forms on the anode particles, which has a huge impact on the performance. The same happens to some extent on the cathode, forming the cathode-electrolyte interphase. Fluorinated polymers and electrolytes are used in the manufacturing of LIBs. The electrolyte in particular is prone to degradation during formation and aging of the batteries. The interface of the cathode material with the aluminum current collector is also a critical point where degraded fluorine components cause pitting corrosion and at the same time promote passivation of the metal foil. Monitoring the spatial distribution of fluorine on these surfaces and interfaces is essential for sustainable LIB production. T2 - SALSA Kick-Off Meeting CY - Berlin, Germany DA - 11.04.2024 KW - Lithium Ion Batteries KW - solid microanalysis KW - depth-profiling KW - fluorine PY - 2024 AN - OPUS4-60199 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wittwer, Philipp A1 - Schneider, Rudolf T1 - Results of ILC Data Treatment N2 - Results of the interlaboratory comparison study for data treatment were presented. They show, that nearly all participants found all the problems in the data. However, only a few corrected the problems, therefore making it one possible point to focus on in the knowledge sharing program. T2 - AGM POLMO Meeting 2024 CY - Paris, France DA - 21.05.2024 KW - JNP POLMO KW - ILC KW - Ringversuch PY - 2024 AN - OPUS4-60166 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -