TY - CONF A1 - Riedel, Jens T1 - Acoustic Ion Manipulation: Electric-field-free Approach to Gate, Focus, and Separate Ions at Atmospheric Pressure N2 - Approaches to control the motion and direction of ionized particles and mole-cules are an essential aspect of ion-based spectrometries, such as mass spec-trometry (MS) and ion mobility spectrometry (IMS). A wide variety of ion optics exist to reflect, focus, separate, gate, and filter ions based on physical proper-ties. Notably all rely on electric and magnetic fields to alter the trajectory of ionized atoms and molecules. While these optics are quite efficient at low pressures due to the large mean free path, diffusion and electrostatic repulsion between ions dominate at higher pressures. Conventional ion optics, that use electric or magnetic fields, can guide ions at atmospheric pressure (AP), but require high field strengths to overcome the dominating aerodynamic effects. Here, we describe a remarkable phenomenon whereby low-power acoustic fields are used to move, shape, gate, and separate beams of gaseous ions at atmospheric pressure. We refer to this approach as Acoustic Ion Manipulation (AIM). Gaseous ions at AP are directed towards and separated by the presence of the acoustic field. To better understand the phenomenon, an ion-detector array provided a measure of bulk ion movement, while mass spectrometry (MS) offered chemical-specific information. As one example of an AIM setup, a standing acoustic wave was formed with two ultrasonic speakers and placed between an ionization source and ion detector. Ion beams preferentially travel through regions of stable pressure gradients (i.e. nodes) and deflect from un-stable regions (i.e. antinodes). Shadowgraphy revealed that the ions are sepa-rated from a neutral gas stream. Specific examples of ion focusing, gating, and separation (based on ion size) will be shown. In addition, experimental findings will be used to postulate a theory to develop a better understand of the behav-ior of gas-phase ions in acoustic fields. This discovery could have profound im-pacts in IMS/MS instrumentation as well as materials processing and charac-terization. T2 - 56. Jahrestagung der DGMS CY - Göttingen, Germany DA - 04.03.2025 KW - Acoustic Ion Manipulation KW - Mass spectrometry KW - Ultrasound PY - 2025 AN - OPUS4-64208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Current Transformations and Challenges through the Eyes of a Scientist at a German Federal Research Agency N2 - Innovative research, harmonized standards, certification of reference products, policy advice and regulatory action. To most researchers, federal research agencies (FRAs) are abstract chimeras as these tasks appear cryptic and unrelated or even entirely incompatible with each other. Instead of one body, they are pictured as a loose conglomerate of individual institutes, agencies, and offices. The German federal institute for materials research and testing (BAM), is currently undergoing a change process to tear down the walls between these disjunct facilities. Apart from an organizational streamlining, such an infrastructure ideally allows for a holistic approach to tackle complex problems. This presentation will shed some light onto the challenges and opportunities arising. Recent years have been dominated by pivotal changes, crises, and challenges. Many scientists see an increasing circularity in material flows and a fossil fuel phase out to be the only feasible way to proceed. By all this, the material world is faced with a plethora of the above mentioned complicate and complex problems. Parallel to these analog challenges, paradigm-changing advancements in robotics, semantic-data technology, and artificial intelligence, currently empower the digital world with unprecedented speed. Using the example of lithium-ion batteries, the talk will showcase modern FRAs as nutritious ecosystem for a holistic approach towards accelerating all future research and development processes. It will give a glimpse of the complex interplay of different stakeholders like industry, politics, researchers, and end-users but also a simultaneous work on simulation, research and development, characterization, standardization, and regularization. After a brief introduction into these different facets of our institute, a deep dive will be given into the development of novel spectroscopic techniques (e.g. laser induced breakdown spectroscopy (LIBS), glow discharge optical emission spectroscopy, and Raman scattering), directly addressing the demands identified by the above stakeholders. Since by design, a future applicability is already included into this chemical characterization methodologies, all the presented techniques all share the same characteristics to be relatively inexpensive, fast, robust and do not need laborious sample preparation. T2 - Institute Seminar CY - Troy, NY, USA DA - 29.10.2024 KW - Federal research KW - Transformation KW - Analytical Chemistry KW - Instrumentation PY - 2024 AN - OPUS4-61971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Winckelmann, Alexander A1 - Morcillo Garcia-Morato, Dalia A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Riedel, Jens A1 - Vogl, Jochen A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Determination of lithium in human serum by isotope dilution atomic absorption spectrometry N2 - The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry. KW - Lithium KW - Human serum KW - Isotope dilution KW - Atomic absorption spectrometry KW - High-resolution continuum source graphite furnace atomic absorption spectrometry PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-532446 DO - https://doi.org/10.1007/s00216-021-03636-6 VL - 414 IS - 1 SP - 251 EP - 256 PB - Springer CY - Berlin AN - OPUS4-53244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zöllner, Moritz T. A1 - Dariz, Petra A1 - Riedel, Jens A1 - Schmid, Thomas T1 - Dolomite and Mg Calcite as Mineral Thermometers in Mortar Binders. A High Resolution Raman Spectroscopic Study N2 - This paper suggests the use of high‐resolution Raman scattering bands of MgCa carbonates as posteriori thermometer minerals in archaeometric studies. Therefore, the thermal behavior of two dolomite samples and the hydration and carbonation reaction in air of the decomposition products were investigated by Raman microspectroscopy. The increase in the calcination temperature resulted in the formation of – Raman silent MgO and – inert Mg calcite at 700°C–750°C. In contrast, the decarbonation, hydration, and recarbonation of sample material exposed to 750°C–900°C in a muffle furnace led to the appearance of Mg‐free calcite. High spectral resolution Raman spectroscopy enabled a spectral distinction between these two groups due to differences in the band parameters (peak position, bandwidth) of the vibrational (v1, v4, L) modes of calcite. In combination with Raman microspectroscopic mapping, this spectral information represents a new approach for the estimation of burning temperatures of medieval high‐fired gypsum mortars via natural dolomite impurities. Thus, the results of this work highlight the importance and potential of Raman microspectroscopy as a thermometric tool for elucidating the thermal history of anthropogenic fired materials, with potential applications for archaeometry and art technology, as well as for quality controls in the frame of the production of mineral mortar binders and ceramics or bricks, respectively. KW - Mineral thermometry KW - Raman spectroscopy KW - Dolomite KW - High-fired gypsum mortar PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-630270 DO - https://doi.org/10.1002/jrs.6810 SN - 1097-4555 SP - 1 EP - 13 PB - Wiley AN - OPUS4-63027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Yi A1 - Xue, Boyang A1 - Riedel, Jens T1 - Enhancement of LIBS plasma in air with organic solvent vapors N2 - Laser-induced breakdown spectroscopy (LIBS) offers versatile, field-deployable elemental analysis; however, compact, high-repetition-rate nanosecond laser systems typically face constraints in power consumption and size, often compromising emission intensity and thus analytical performance. We demonstrate a significant improvement in LIBS signals through the controlled introduction of common organic solvent vapors into a sheath gas, with a diode-pumped solid-state laser (1064 nm, 2–28 kHz repetition rate, 450–600-μJ pulse energy). Optical and acoustic diagnostics reveal up to ca. 40-fold enhancement of the N II emission line at 567 nm when ambient air serves as the analyte. Maximal enhancement occurs at intermediate repetition rates of ca. 15 kHz, particularly at pulse energies approaching the optical breakdown threshold; this observation suggests a viable strategy for operating LIBS at lower pulse energies and higher repetition rates. Enhancement effects scale jointly with both vapor pressure and ionization energy of the organic species, with acetone and toluene markedly outperforming methanol and isopropanol. These findings provide a rational foundation for significantly improving the analytical performance of portable LIBS instruments without exceeding platform-specific constraints. KW - LIBS PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653758 DO - https://doi.org/10.1016/j.sab.2025.107309 SN - 0584-8547 VL - 236 SP - 1 EP - 6 PB - Elsevier B.V. AN - OPUS4-65375 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Xue, Boyang A1 - Wang, Zhangjun A1 - Zhu, Tao A1 - Gu, Yezhen A1 - Sun, Weihong A1 - Chen, Chao A1 - Li, Zhigang A1 - Riedel, Jens A1 - You, Yi T1 - High repetition-rate laser-induced breakdown spectroscopy combined with two-dimensional correlation method for analysis of sea-salt aerosols N2 - Laser-induced breakdown spectroscopy (LIBS) offers a tantalizing glimpse into real-time, on-the-spot aerosol analysis. Yet, the reliance on traditional lasers, with their limitations in energy and frequency, hampers optimal sample handling, dissociation, and excitation. To address those challenges, we propose a novel tactic: utilize a high repetition-rate (rep.-rate) laser with low pulse energy in combination with the two-dimensional correlation (2D-corr.) technique for sea-salt aerosols analyses. By examining the emission patterns from both the laser pulse train and individual pulses, we recognize distinctive analyte-specific rep.-rate responses, which allowed spectral reconstruction of analytes, avoiding background interferences. This discovery enabled the rep.-rate modulation for a 2D-corr. spectroscopy workflow. Consequently, we successfully differentiated between particle-related and air-species-related spectral components, obviating expensive spectrometers or intensified image detectors. For instance, the Na I at 589 nm stemming from aerosols exhibited an entirely different correlation contribution compared to O I at 777 nm, resulting in reconstructed clean aerosol-spectra without spectral peaks originated from air species. This 2D-corr. aerosol LIBS approach shows promising analytical potential streamlining aerosol particle analysis. KW - LIBS KW - Aerosol PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613392 DO - https://doi.org/10.1016/j.sab.2024.107048 SN - 0584-8547 VL - 221 SP - 1 EP - 8 PB - Elsevier AN - OPUS4-61339 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Winckelmann, Alexander A1 - Nowak, S. A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Riedel, Jens A1 - Vogl, Jochen A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - High-Resolution Atomic Absorption Spectrometry Combined With Machine Learning Data Processing for Isotope Amount Ratio Analysis of Lithium N2 - An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other. KW - Lithium KW - Isotope KW - Machine learning KW - Algorithms KW - Reference material KW - AAS KW - Atomic Absorption Spectrometry PY - 2021 DO - https://doi.org/10.1021/acs.analchem.1c00206 SN - 1520-6882 VL - 93 IS - 29 SP - 10022 EP - 10030 PB - American Chemical Society CY - Washington, DC, USA AN - OPUS4-53028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mohan, M. A1 - Prochazka, D. A1 - You, Yi A1 - Riedel, Jens A1 - Gornushkin, Igor A1 - Rocnakova, I. A1 - Papula, M. A1 - Porízka, P. A1 - Kaizer, J. T1 - Investigating plasma morphology at material boundaries under varying ambient pressures N2 - Laser-Induced Breakdown Spectroscopy (LIBS) is a widely used technique for elemental analysis. The analysis of the obtained LIBS spectra generally assumes plasma homogeneity. However, using focused laser beams for interrogation, LIBS probes materials on the microscale and is, thus, prone to artefacts from sample heterogeneities on the micrometer scale. An ablation at a material boundary of two matrices may result in a significant inhomogeneity in the plasma plume, which can severely impact the accuracy of quantitative analysis. Since this propagation of the surface morphology into the plasma plume is driven by the plasma expansion, its final impact is strongly pressure dependent. This study examines the influence of varying ambient pressures (7–1000 mbar) on plasma morphology, spectral characteristics, and key plasma properties such as electron number density at a well-defined Cu–Sn boundary, in comparison with the results obtained using homogeneous alloys. Several approaches of plasma imaging with bandpass filters, spectroscopy, and Radon transform-based 3D reconstruction were employed to analyze elemental distribution, signal-to-noise (SNR) and signal-to-background (SBR) ratios, as well as electron number densities. The 3D reconstructions revealed a pronounced plasma asymmetry for the ablation at the material boundary, in contrast to the near-axial symmetry observed for the ablation of homogeneous alloys. At lower pressures, this distinct elemental separation in plasma persisted, while higher pressures led to an increased collisional mixing and homogenization. SNR and SBR were consistently lower for ablation at the boundary compared to homogeneous samples. These findings highlight how boundary ablation contributes to plasma inhomogeneities in LIBS analysis of heterogeneous materials and emphasize the need to account for these effects when using LIBS for elemental mapping of fine heterogeneous structures. KW - Laser-induced breakdown spectroscopy KW - Plasma inhomogeneity KW - Plasma tomography KW - Radon transform KW - Material boundaries KW - Ambient pressure effects PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-634777 DO - https://doi.org/10.1016/j.talanta.2025.128377 SN - 1873-3573 VL - 295 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-63477 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Is LIBS ready for the future? N2 - Recent years have brought up many challenges for an analytical tracing of material flows. While planetary boundaries force end of life material into circular recycling pathways, geopolitical tension creates demands regarding the origin of raw materials. The analytical demands on any instrumentation to tackle the arising challenges of this scenario are straight forward: No sample preparation, precision in the percentage region, and high throughput at comparably low cost. All these demands make LIBS a perfect candidate, why it is time for a re-evaluation of how it exploits the potential possibilities arising from todays’ technology. While being a relatively young technique, the vast majority of conducted LIBS experiments still relies on well established instrumentation, sometimes ignoring the innovations and breakthroughs in the development of its empowering technology sectors such as battery powered compact high repetition rate lasers with tuneable pulse rate and length, low priced cameras with millions of small sized pixels and extremely fast shutter and readout times, optical modulators, galvonometer scanners, and simple robotics. In this talk we will showcase some examples on how the implantation of all these new tools can lead to extremely affordable and compact instrumentation with unprecedented acquisition speed and a spectral resolution sufficient to resolve atomic isotope lines. T2 - FACCS SCiX CY - Raleigh, NC, USA DA - 20.10.2024 KW - LIBS KW - Isotopes KW - Instrumentation PY - 2024 AN - OPUS4-61970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - van Wasen, S. A1 - You, Yi A1 - Beck, S. A1 - Riedel, Jens A1 - Volmer, D. A. T1 - Laser Ablation Secondary Electrospray Ionization for In Situ Mass Spectrometric Interrogation of Acoustically-Levitated Droplets N2 - The composition of acoustically levitated droplets was probed by a novel combination of mid-IR laser evaporation and subsequent postionization via secondary electrospray ionization. The combination of microliter samples and subnanoliter sampling provided time-resolved interrogation of droplets and allowed for a kinetic investigation of the laser-induced release of the analyte, which was found to strongly depend on the analytes. The observed substancespecific delayed release of the analytes permitted baseline-separated discrimination of the analytes, ideal for the study of complex samples. The additionally applied postionization scheme was found to enable efficient detection of small volatile compounds as well as peptides. The detection of small molecules and peptides occurred under very different sampling geometries, pointing to two distinct underlying ionization mechanisms. Overall, our results suggest that the experimental setup presented in this study can serve as a widely applicable platform to study chemical reactions in acoustically levitated droplets as model reactors. KW - Acoustic levitation KW - Mass spectrometry KW - Electrospray KW - Laser ablation PY - 2022 DO - https://doi.org/10.1021/acs.analchem.2c03800 SN - 0003-2700 VL - 2022 SP - 1 EP - 5 PB - ACS Publications CY - Washington AN - OPUS4-56531 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -