TY - JOUR A1 - Kittner, Maria A1 - Kerndorff, A. A1 - Ricking, M. A1 - Bednarz, M. A1 - Obermaier, N. A1 - Lukas, M. A1 - Asenova, M. A1 - Bordós, G. A1 - Eisentraut, Paul A1 - Hohenblum, P. A1 - Hudcova, H. A1 - Humer, F. A1 - István, T. G. A1 - Kirchner, M. A1 - Marushevska, O. A1 - Nemejcová, D. A1 - Oswald, P. A1 - Paunovic, M. A1 - Sengl, M. A1 - Slobodnik, J. A1 - Spanowsky, K. A1 - Tudorache, M. A1 - Wagensonner, H. A1 - Liska, I. A1 - Braun, U. A1 - Bannick, C. G. T1 - Microplastics in the Danube River Basin: A First Comprehensive Screening with a Harmonized Analytical Approach N2 - In this study, carried out within the Joint Danube Survey 4, a comprehensive microplastic screening in the water column within a large European river basin from its source to estuary, including major tributaries, was realized. The objective was to develop principles of a systematic and practicable microplastic monitoring strategy using sedimentation boxes for collection of suspended particulate matter followed by its subsequent analysis using thermal extraction desorption-gas chromatography/mass spectrometry. In total, 18 sampling sites in the Danube River Basin were investigated. The obtained suspended particulate matter samples were subdivided into the fractions of >100 μm and <100 μm and subsequently analyzed for microplastic mass contents. The results showed that microplastics were detected in all samples, with polyethylene being the predominant polymer with maximum contents of 22.24 μg/mg, 3.23 μg/mg for polystyrene, 1.03 μg/mg for styrene-butadiene-rubber, and 0.45 μg/mg for polypropylene. Further, polymers such as different sorts of polyester, polyacrylates, polylactide, and natural rubber were not detected or below the detection limit. Additional investigations on possible interference of polyethylene signals by algae-derived fatty acids were assessed. In the context of targeted monitoring, repeated measurements provide more certainty in the interpretation of the results for the individual sites. Nevertheless, it can be stated that the chosen approach using an integrative sampling and determination of total plastic content proved to be successful. KW - Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring KW - Microplastics KW - River KW - Suspended particulate matter (SPM) KW - Sedimentation box (SB) PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-551444 DO - https://doi.org/10.1021/acsestwater.1c00439 VL - 2 IS - 7 SP - 1174 EP - 1181 PB - ACS Publications AN - OPUS4-55144 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Sweetening the (microplastics) pill: PET tablets (1-100µm) as candidate reference material for the validation of microplastics measurement N2 - The lack of validation and standard procedures in microplastics studies has led to the inability to compare and harmonise data from different analytical methods, laboratories and time scales. To monitor and regulate exposure to microplastics in the environment and in food for human health, it is crucial to ensure their comparability and to validate the analytical methods used in microplastics studies. Monitoring microplastics requires complex approaches for accurate determination otherwise it can lead to an over- or underestimation in environmental and food-relevant matrices. Moreover, to support the need of reliable measurement required by the European legislation directive on drinking water (EU 2020/2184) or the revision of the urban waste water directive, which will be finalised in 2024 the production and validation of polymeric reference materials with environmentally relevant concentrations, irregular shapes, defined aging status and different sizes is essential. The production of reference material with acceptable uncertainties in homogeneity need to be balanced, considering the low microplastics concentrations detected in the environment and in food. The aim of the project PLASTICTRACE and of this study, is to propose a “easy-to-use PET tablet ” (PET particle size mainly 1-100 µm) for routine applications as a candidate general reference material for detection methods. Batches of water-soluble matrix containing different concentrations of PET powder were produced. Results of imaging and counting methods (SEM, Laser diffraction), including production´s challenges; together with thermo-analytical methods (TED-GC/MS and Py-GC/MS) and vibrational spectroscopy (µ-Raman and µ-FTIR), will be presented. These data are useful to assess homogeneity and stability of the particles over time according to ISO 33405:2024. In addition, we will show some insights on the application of the PET-tablets in complex matrices, as milk powder and suspended solid from surface water, that could be easily used for routine microplastics analysis. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Reference materials KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Engelhard, Carsten T1 - On ICP-MS with Nanosecond Time Resolution: From Nanoparticles to Microplastics N2 - In this presentation, recent developments in inductively coupled plasma mass spectrometry (ICP-MS) instrumentation for particle characterization in complex mixtures will be reviewed. The current state-of-the-art in single-particle (sp) ICP-MS instrumentation for the detection and characterization of nanoparticles (NP) and microplastics (MPs) as well as remaining challenges will be discussed. While millisecond dwell times were used in the advent of spICP-MS, the use of microsecond dwell times helped to improve nanoparticle data quality and particle size detection limits. We could show that a custom-built high-speed data acquisition unit with microsecond time resolution (μsDAQ) can be used to successfully address issues of split-particle events and particle coincidence, to study the temporal profile of individual ion clouds, and to extend the linear dynamic range by compensating for dead time related count losses. Our latest development is an in-house built data acquisition system with nanosecond time resolution (nanoDAQ). Recording of the SEM signal by the nanoDAQ is performed on the nanosecond time scale with a dwell time of approximately 2 ns and enables detection of gold nanoparticles (AuNP) as small as 7.5 nm with a commercial single quadrupole ICP-MS instrument. [1] Analysis of acquired transient data is based on the temporal distance between detector events and a derived ion event density. It was shown that the inverse logarithm of the distance between detector events is proportional to particle size. Also, the number of detector events per particle can be used to calibrate and determine the particle number concentration (PNC) of a nanoparticle dispersion. In addition to inorganic nanoparticles, first results on the detection of microplastics with spICP-MS will be discussed. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Nano KW - Microplastics KW - Nanoparticle Characterization KW - ICP-MS KW - Instrumentation PY - 2025 AN - OPUS4-63580 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Escobar-Carranza, Cristian C. T1 - On the Detection of Microplastics by Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (FAPA-MS) N2 - Microplastics (MPs) are widespread pollutant particles that can be analyzed using Raman and FTIR spectroscopy combined with optical microscopy. Additionally, pyrolysis (Py) or thermal extraction and desorption (TED) coupled with gas chromatography-mass spectrometry (GC-MS) are used for the characterization of MPs.[1] However, sample throughput is limited due to GC separation. This work presents a feasibility study for the direct, rapid analysis of MPs using high-resolution mass spectrometry and a plasma-based ambient desorption/ionization source (FAPA, flowing atmospheric-pressure afterglow).[2] In earlier work, an in-house built ambient ionization source (modelled after the pin-to-capillary (p2c) FAPA design by Shelley et al. [3]) was coupled to HR-Orbitrap MS and used to characterize different MPs produced in-house from plastic materials including polystyrene (PS), polypropylene (PP), low-density polyethylene (LDPE), and polycarbonate (PC). Simultaneous detection of characteristic ions and particle imaging on a sampling mesh was feasible, with detection limits (LOD) for PS MPs at 311 µm in size and 1.3 mg in mass. Principal component analysis (PCA) was used for particle differentiation. This work presents an improved desorption/ionization approach using higher temperatures for desorption enhancement (approximately 500 °C, achieved with economical and commercially available parts) and a tailored source housing combined with a halo-shaped (h-FAPA) source configuration.[4] The scope was expanded to include MPs from poly(ethylene terephthalate) (PET), poly(methyl methacrylate) (PMMA), and poly(vinyl chloride) (PVC), sized 125–250 µm. Data visualization and interpretation were performed using Kendrick mass defect plots and other multivariate analysis tools. Compared to earlier results, h-FAPA-MS yielded at least 65% higher ion signals for selected ions in all MPs. These ions were detected mainly as protonated species [M+H]+. Higher thermal desorption temperatures aided in detecting all MPs, as the presence of higher molecular weight fragments added specificity to the analysis. Notably, experiments with the h-FAPA source demonstrated lower mass-based LODs for MPs than the p2c-FAPA source (e.g., 14 µg vs 1.3 mg for PS, respectively). T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Mass Spectrometry KW - Plasma KW - FAPA-MS KW - Microplastics PY - 2025 AN - OPUS4-63604 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schütz, Désirée A.-M. T1 - Feasibility Study on the Adsorption of Environmental Contaminants onto Fresh and Aged Microplastics N2 - Microplastics (MPs) refer to plastic particles, fibers, or beads with sizes ranging from 100 nm to 5 mm in size. Their pervasive distribution as environmental contaminants have escalated into a significant global concern. Primary MPs are intentionally produced particles for industrial and commercial applications, such as exfoliants in personal care and cosmetic formulations. In contrast, secondary MPs are generated through the fragmentation and degradation of larger plastic materials, due to environmental weathering processes. [1] Due to their high surface area-to-volume ratio and hydrophobic nature, MPs have the potential to serve as vectors for the accumulation and transport of diverse organic contaminants, including polycyclic aromatic hydrocarbons (PAHs), perfluoroalkyl substances (PFAS), pharmaceuticals and personal care products (PPCPs), as well as trace metals such as silver, cadmium, chromium, and copper. In the environmental, MPs are subject to aging processes driven by factors such as temperature, ultraviolet radiation, oxygen, and chemical interactions with environmental toxins. This aging can induce significant alterations in their physicochemical properties, which, in turn, can affect the adsorption behavior. [2] Classical and alternative analytical methods such as high-performance liquid chromatography (HPLC) and ambient desorption/ionization high-resolution mass spectrometry (ADI-HR-MS) can help to study the adsorption potential. ADI-HR-MS allows rapid sample analysis with minimal preparation, providing results in under a minute, much faster than traditional chromatographic techniques. [3] This study aims to investigate the influence of aging and particle size on the ability of microplastics to act as vectors for environmental contaminants. Microplastics were prepared in-house and subjected to controlled aging conditions for 12, 24, 36, and 48 hours. Subsequently, the aged MPs were exposed in plastic-free containers to model solutions to simulate co-contaminants in the environment. Adsorption onto synthesized secondary microplastics, varying in size and aging status, was investigated at different time intervals with ambient MS and time-of-flight secondary ion mass spectrometry. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Mass Spectrometry KW - FAPA-MS KW - Microplastics KW - TOF-SIMS KW - Surface Analysis PY - 2025 AN - OPUS4-63606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schütz, Désirée A.-M. T1 - Feasibility Study on the Adsorption of Environmental Contaminants onto Fresh and Aged Microplastics N2 - Microplastics (MPs) refer to plastic particles, fibers, or beads with sizes ranging from 100 nm to 5 mm in size. Their pervasive distribution as environmental contaminants have escalated into a significant global concern. Primary MPs are intentionally produced particles for industrial and commercial applications, such as exfoliants in personal care and cosmetic formulations. In contrast, secondary MPs are generated through the fragmentation and degradation of larger plastic materials, due to environmental weathering processes. [1] Due to their high surface area-to-volume ratio and hydrophobic nature, MPs have the potential to serve as vectors for the accumulation and transport of diverse organic contaminants, including polycyclic aromatic hydrocarbons (PAHs), perfluoroalkyl substances (PFAS), pharmaceuticals and personal care products (PPCPs), as well as trace metals such as silver, cadmium, chromium, and copper. In the environmental, MPs are subject to aging processes driven by factors such as temperature, ultraviolet radiation, oxygen, and chemical interactions with environmental toxins. This aging can induce significant alterations in their physicochemical properties, which, in turn, can affect the adsorption behavior. [2] Classical and alternative analytical methods such as high-performance liquid chromatography (HPLC) and ambient desorption/ionization high-resolution mass spectrometry (ADI-HR-MS) can help to study the adsorption potential. ADI-HR-MS allows rapid sample analysis with minimal preparation, providing results in under a minute, much faster than traditional chromatographic techniques. [3] This study aims to investigate the influence of aging and particle size on the ability of microplastics to act as vectors for environmental contaminants. Microplastics were prepared in-house and subjected to controlled aging conditions for 12, 24, 36, and 48 hours. Subsequently, the aged MPs were exposed in plastic-free containers to model solutions to simulate co-contaminants in the environment. Adsorption onto synthesized secondary microplastics, varying in size and aging status, was investigated at different time intervals with ambient MS and time-of-flight secondary ion mass spectrometry. T2 - 56th Annual Conference of the DGMS CY - Göttingen, Germany DA - 04.03.2025 KW - FAPA-MS KW - Mass Spectrometry KW - Microplastics KW - Surface Analysis KW - TOF-SIMS PY - 2025 AN - OPUS4-63644 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Escobar-Carranza, Cristian C. T1 - On the Detection of Microplastics by Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (FAPA-MS) N2 - Microplastics (MPs) are widespread pollutant particles analyzed using Raman and FTIR spectroscopy combined with optical microscopy. Pyrolysis (Py) or thermal extraction and desorption (TED) coupled with gas chromatography-mass spectrometry (GC-MS) are used for the characterization of MPs, though GC limits sample throughput. This work explores direct, rapid MP analysis using high-resolution (HR) MS and a plasma-based ambient desorption/ionization source (FAPA, flowing atmospheric-pressure afterglow). Previously, an in-house pin-to-capillary (p2c) FAPA source coupled to HRMS characterized MPs made in-house from polystyrene (PS), polypropylene (PP), low-density polyethylene (LDPE), and polycarbonate (PC). Simultaneous detection of characteristic ions and particle imaging on a sampling mesh was feasible, with detection limits (LOD) for PS MPs at 311 µm in size and 1.3 mg in mass. Principal component analysis (PCA) was used for particle differentiation. This work introduces a high-temperature desorption method (~500 °C) with economical and commercially available parts and a tailored housing combined with a halo-shaped (h-FAPA) source configuration. The study expands to include poly(ethylene terephthalate) (PET), poly(methyl methacrylate) (PMMA), and poly(vinyl chloride) (PVC) MPs (125–250 µm). Data visualization and interpretation were performed using Kendrick mass defect plots and other multivariate analysis tools. Compared to earlier results, h-FAPA-MS yielded at least 65% higher ion signals for selected ions in all MPs. These ions were detected mainly as protonated species [M+H]+. Higher thermal desorption temperatures aided in detecting all MPs, as the presence of higher molecular weight fragments added specificity to the analysis. Notably, experiments with the h-FAPA source demonstrated lower mass-based LODs for MPs than the p2c-FAPA source (e.g., 14 µg vs 1.3 mg for PS, respectively). T2 - 56th Annual Conference of the German Society for Mass Spectrometry (DGMS) CY - Göttingen, Germany DA - 04.03.2025 KW - Instrumentation KW - Mass Spectrometry KW - FAPA-MS KW - Microplastics PY - 2025 AN - OPUS4-63663 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Preliminary results of an interlaboratory comparison on microplastics organised by plasticsfate N2 - Microplastics are everywhere in the environment, but analytics is challenging. Since harmonisation is missing as well es suitable reference materials, BAM did under th umbrella of VAMAS funded by the EU Horizon 2020 project PlasticsFate a ILC for microplastic detection methods. Methods adressed were IR, Raman, Py-GC/MS and TED-GC/MS. The talk gives a first presentation and evaluation on the results. T2 - CUSP annual meeting and conference CY - Utrecht, Netherlands DA - 12.09.2023 KW - Microplastics KW - TED-GC/MS KW - Polymer 3R KW - Reference material KW - ILC on detection methods PY - 2023 AN - OPUS4-60036 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Giovannozzi, A T1 - Standardization and Harmonization Effort on Microplastics Analysis by Spectroscopic Methods N2 - This talk presents the EU funded project PlasticTrace. It shows the challenges in micro- and nanoplastic reference materials and gives some solutions regarding spectroscipc methods such as Raman or IR microscopy to determine the particle numbers. Materials are prepared by cryo milling to get some powder that is later pressed into tablets. The polymer type used is PET, because that is highly important for drinking water directive of EU commission. T2 - International Conference on Raman Spectroscopy (ICORS) CY - Roma, Italy DA - 28.07.2024 KW - Microplastics KW - Reference materials KW - Polymer 3R PY - 2024 AN - OPUS4-60881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Goedecke, Caroline A1 - Bannick, C.-G. A1 - Abusafia, A. A1 - Scheid, C. A1 - Steinmetz, H. A1 - Paul, Andrea A1 - Beleites, C. A1 - Braun, U. T1 - Identification of microplastic pathways within a typical European urban wastewater system N2 - In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other. KW - Microplastics KW - Microplastic analysis KW - TED-GC/MS KW - Microplastic pathways KW - Mass contents PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568289 DO - https://doi.org/doi.org/10.1002/appl.202200078 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oksal-Kilinc, Sefine A1 - Altmann, Korinna A1 - Seiwert, Bettina A1 - Reemtsma, Thorsten A1 - Ruess, Liliane T1 - Grinding method and oxidative aging modulate the impact of tire wear microplastics on the reproduction of the nematode C. elegans N2 - Rationale Tire abrasion is one of the largest sources of microplastic in aquatic and terrestrial environments. Despite this fact, research on tire wear microplastic (TWP) and its effects on soil ecosystems is scarce, especially regarding natural weathering processes. This leaves a large knowledge gap on the interactions of TWP with soil biota. Methodology Cryo-milled tire tread (CMTT) and diamond-ground tire tread (DGTT) were artificially weathered through dry ozone treatment and heat exposure. Particles were analyzed via scanning electron microscopy, particle size distribution, and shape characterization. TWP leachate composition was examined using liquid chromatography–mass spectrometry. The impact on the reproduction of the nematode Caenorhabditis elegans, a widely used toxicological model, was tested for leachate concentration, exposure duration and TWP aging status, using offspring per adult as the endpoint. Results The comminution method significantly influenced TWP particle size distribution, with diamond grinding yielding smaller particles and a more structured surface morphology than cryo-milling. Aging with ozone (180 min) and heat (20 min at 100 °C) reduced DGTT particle sizes by 27-58%, but not in CMTT. Additionally, aging increased carboxylic functional groups and led to a brittle structure in both TWP types. Leachate composition varied with comminution method and aging. Benzothiazole, N-Cyclo-N-phenylurea, and aniline were more abundant in pristine and aged CMTT and aged DGTT. Diphenylguanidine had the highest concentration in all leachates. Aged TWP leachates, regardless of comminution, had significant toxic effects on C. elegans. Leachate from pristine CMTT was more toxic than from pristine DGTT. Nematode offspring correlated negatively with ozone exposure duration in aged DGTT. Tests with aged CMTT leachate showed even short-term exposure reduced offspring numbers. Discussion The results underscore the importance of oxidative and mechanical weathering in TWP toxicity and challenge the use of pristine particles in toxicological assays for risk assessment in the natural environment. KW - Microplastics KW - Tire abrasion KW - Environment PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654672 DO - https://doi.org/10.1071/EN25051 SN - 1448-2517 VL - 23 IS - 2 SP - 1 EP - 16 PB - CSIRO Publishing AN - OPUS4-65467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Putzu, Mara A1 - Wiesner, Yosri A1 - Weimann, Christiane A1 - Hodoroaba, Vasile-Dan A1 - Muniategui Lorenzo, Soledad A1 - Fernández-Gonzáles, Verónica A1 - Booth, Andy M. A1 - Igartua, Amaia A1 - Benismail, Nizar A1 - Coïc, Laureen A1 - Chivas-Joly, Carine A1 - Fenoglio, Ivana A1 - Rossi, Andrea Mario A1 - Giovannozzi, Andrea Mario A1 - Altmann, Korinna T1 - Optimization of tablet processing as a reference material for microplastic detection methods N2 - Reference materials (RMs) are essential and highly demanded tools for the development and validation of methods for microplastic (MP) quantification in complex matrices, to ensure comparable and harmonized approaches aligned with EU commission criteria for monitoring MPs (e.g., Drinking Water Directive and Urban Wastewater Treatment Directive). This study investigates different approaches for optimizing the production of polypropylene (PP) RMs in the form of water-soluble tablets, which were carefully evaluated for their homogeneity and stability according to ISO Guide 30, ISO 33401, and ISO 33405. PP particles (1–100 μm) were produced by cryomilling and embedded in a lactose/PEG matrix, then pressed into tablets (18 µg theoretical PP mass). The production process was optimized by varying (i) the size distribution of the matrix components and (ii) the mixer instrument. The materials obtained were characterized by thermogravimetric analysis to assess the homogeneity distribution of MPs with respect to PP mass in the individual tablets and their stability over a 4-month period. The most promising approach, with a homogenous mass of 19 μg (standard deviation of 4 μg), relative standard deviation of 19%, was further investigated for homogeneity by comparison with thermo-analytical mass determination methods, such as TED-GC/MS (thermal extraction desorption-gas chromatography/mass spectrometry) and Py-GC/MS (pyrolysis-gas chromatography-mass spectrometry), and for number-based characterization using micro-Raman spectroscopy. Material characterization was also examined using laser diffraction, scanning electron microscopy, and ATR-FTIR. Based on the results, the optimized processing protocol yields a PP RM suitable for quality control and method performance studies supporting standardization. KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polypropylene PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653290 DO - https://doi.org/10.1007/s00216-025-06271-7 SN - 1618-2642 SP - 1 EP - 14 PB - Springer Science and Business Media LLC AN - OPUS4-65329 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Putzu, Mara A1 - Barbaresi, Marta A1 - Fadda, Marta A1 - Sacco, Alessio A1 - Piergiovanni, Maurizio A1 - Masino, Matteo A1 - Bianchi, Federica A1 - Altmann, Korinna A1 - Benismail, Nizar A1 - Coïc, Laureen A1 - Fenoglio, Ivana A1 - Mattarozzi, Monica A1 - Rossi, Andrea Mario A1 - Careri, Maria A1 - Giovannozzi, Andrea Mario T1 - Accuracy assessment of a micro-Raman spectroscopy method for small microplastic particles in infant milk formula N2 - The presence of microplastics (MPs) in the food chain is increasingly documented, raising concerns over potential risks to human health. Despite growing efforts, standardized methods for MPs detection in food matrices remain limited. This study presents an interlaboratory comparison (ILC) aimed at assessing the accuracy and comparability of an analytical approach for the identification and quantification of small MPs (5–100 μm) in infant milk powder using μ-Raman spectroscopy and a representative polyethylene terephthalate (PET) reference material (RM). The RM, formulated as water-soluble tablets, was designed to replicate the morphology, size distribution, and polymer composition of environmentally relevant MPs, and was previously assessed for homogeneity and stability for mass fraction and particle numbers. The approach was assessed using two PET RM batches with different MPs particle numbers (high load batch: 1759 ± 141 MPs; low load batch: 160 ± 22 MPs), subjected to an enzymatic–chemical digestion, followed by μ-Raman analysis performed independently in two laboratories with different instruments and operators. Results are reported as absolute particle counts per analyzed sample and demonstrated excellent recovery across all size classes, including the smallest particles (down to 5 μm), with recovery rates ranging from 82 % to 88 %, in good agreement with the RM reference values. The analytical approach proved to be robust, reproducible, and suitable for low-level MPs quantification in complex food matrices, supporting ongoing efforts toward method harmonization and standardization for reliable MPs monitoring in the food sector. KW - Microplastics KW - Milk KW - Raman microspectroscopy PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646239 DO - https://doi.org/10.1016/j.talo.2025.100586 SN - 2666-8319 VL - 12 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-64623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Eisentraut, Paul A1 - Altmann, Korinna T1 - One Year Observation of Microplastic Concentrations in the River Rhine N2 - In recent years, the quantification of microplastics (MP) in aquatic environments has gained increasing attention, particularly regarding their environmental distribution and potential exposure levels. Environmentally relevant exposure data are still essential for a realistic risk assessment of the harmful health potential of microplastics in freshwater systems. This study addresses a large data set of MP concentrations analyzed and processed under statistical aspects and provides mass concentrations as well as associated size fractions of the detected MP. Over a 12 month period, samples were collected at three locations and analyzed across three particle size fractions (100−500 μm, 50−100 μm, and 10−50 μm) using thermalextraction desorption-gas chromatography/mass spectrometry (TED-GC/MS). The most prevalent polymers identified were polyethylene (PE), polypropylene (PP), polystyrene (PS), styrene−butadiene rubber (SBR), and natural rubber (NR). Statistical analyses, including principal component and cluster analysis, revealed size-dependent patterns,minor seasonal variation and spatial variations. These findings are particularly significant for ecotoxicological research and regulatory development, especially regarding tire abrasion a rarely quantified but potentially harmful MP source. The study contributes aluable data for future environmental monitoring and supports EU directives on wastewater and drinking water quality KW - TED-GC/MS KW - Microplastics KW - Environment KW - Monitoring KW - Reference data PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654669 DO - https://doi.org/10.1021/acsestwater.5c00530 SN - 2690-0637 SP - 1 EP - 10 PB - American Chemical Society (ACS) AN - OPUS4-65466 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Textile Fibers as Reference Materials for Microplastic Release N2 - Fibers of textile origin are named as high contributor for microplastic pollution in the environment next to e.g. plastics from packaging, tire wear and paints. Small fibers and fragments (microplastics: 1-1000 µm) can be released from textiles by mechanical abrasion during application (e.g. wearing) or washing. To date, the occurrence, transport pathways, and impacts of such small fibers on the environment and human health remain unclear. The European Commission revised the Urban Wastewater Treatment Directive (Directive (EU) 2024/3019) and made monitoring of microplastics mandatory in the next years. Additionally, standards for microplastic detection are developed in the ISO standardization body ISO/TC 147/SC 2 with the documents ISO/DIS 16094-2 and ISO/DIS 16094-3. Detection mainly occurs by thermoanalytical methods for mass or vibrational methods with microscopes for numbers. Such standards and regulatory efforts need validated methods, which themselves need reference materials for validation. Reference materials are well characterized materials that are produced for a specific purpose and are homogeneous and stable within one property of interest. The shape and the composition of the reference particles/fibers will affect the detection, hence it is important to validate the instruments with fibers, if this is the task for monitoring campaigns. This work describes the production of realistic fibers as reference material for microplastic analysis. The individual samples contain of a small number (< 1000) and mass (< 20 µm) of fibres. Homogeneity and stability control occurred by thermogravimetric analysis and µ-Raman. Further characteristics were determined for type, shape and size distribution. T2 - TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Reference materials KW - Microfibers KW - Microfiber release PY - 2025 AN - OPUS4-64620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Visileanu, Emilia A1 - Catalin Grosu, Marian A1 - Tiberiu Miclea, Paul A1 - Altmann, Korinna A1 - Brossell, Dirk T1 - Methods for the collection and characterization of airborne particles in the textile industry N2 - Airborne particulate matter is one of the main air pollutants. Their impact on mortality, and the occurrence of pulmonary and cardiovascular complications, have been the subject of numerous studies. Airborne particles are complex mixtures of organic and inorganic substances from different sources of particle emissions. Particulate Matter (PM) particles are classified according to their aerodynamic diameter expressed in µm and can vary from coarse (PM 10) to fine (less than PM 2.5). These diameter considerations are fundamental because they condition the penetration of particles into the bronchopulmonary system and the body. In recent years, there has been an interest in so-called “ultra-fine” particles, with a diameter of 0.1 µm (or 100 nm), or PM 0.1. They are nanoparticles and their impact on human health is not yet clear.With more than 1.5 million employees, textiles and clothing is a diverse sector that plays an important role in the European manufacturing industry, producing a turnover of €162 billion.An important component of the solid particles that generate air pollution in the textile industry is microplastics (MP) and nano plastics (NP), which also include microfibers (<5mm) and nanofibers (<100 nm), respectively. The particles released into the air during fiber and yarn processing range from 1 µg/m3 to 50 µg/m3.The paper presents the results of the determination of indoor and outdoor air concentration levels in textile companies, to identify the areas with the highest concentration level, by using an online recording system such as the Laser Aerosol Spectrometer MINI LAS model 11-E. The total concentration level TSP (µg/m3), the fractions PM 10(µg/m3), PM 2.5(µg/m3), PM1(µg/m3), as well as the total number of particles TC (1/l), were shown. It was noted that TSP is approximately at the same level both indoors and outdoors, but the fractions of PM10, PM2.5, and PM1 have much higher values indoors than outdoors with possible consequences on workers' health.The next step was the collection of fibers, namely micro and nano plastic particles from the vicinity of the workplaces of polyester, polyamide, and polypropylene fibers processing units in the textile industry in Romania, to obtain a sufficient quantity for laboratory analysis to determine the size and shape of the particles as well as their chemical composition. Two types of pumps were used, differentiated by their operating parameters: TECORA SKYPOST with airflow of 38 l/min and GILAIRPLUS with airflow 2l/min. Filters made of different materials with different diameters and pore sizes were used, namely: quartz filters (ø 47 mm, and ø 37 mm) on a TECORA SKYPOST type pump, polycarbonate nucleopore coated with a gold membrane (ø 25 mm) and silica filter (ø 9 mm) on GILAIRPLUS type pump.Using descriptive statistics, the calculation of correlation coefficients highlighted a strong correlation between the variables: "Collected mass/ Air concentration" and "Collected mass/ Air volume" for all diameters of the filters.The highest collected particle volume, determined by weighing the filters before and after collection, was obtained with the quartz filters (ø 47 mm) at an airflow of 38 l/min. The particles collected (polyester, polyamide, polypropylene) in the first stage were analyzed by SEM and thermogravimetric and it was found that the quartz filters absorbed the particles inside, with very few remaining on the surface. Thus no known methods can be used to perform analysis for particles collected on quartz filters. The number of particles on the filters was insufficient for analysis either because of the collection parameters used or because of the loss of particles during transport. As a result, in the next step, the use of 9 mm Si filters using the GILAIRPLUS pump at an airflow rate of 2l/min was chosen.To improve the transport conditions and avoid the loss of the particles and keep them on the surface of the filters, two methods were applied:- after weighing the filters were reintroduced into the collection pump holder;- a filtration system for airborne micro-nano plastics was designed and manufactured to selectively collect and transport PM10 and PM1 particles collected on SI filters.In both cases, SEM, Raman mapping, and GS-MS microscopy were used for analysis.Several times more PM10 than PM1 (74.5µg compared to 12.5 µg) was found. In all cases, both particles and fibers showed the same Raman fingerprint.The GS-MS analyses showed some contamination of the workspaces with particles other than the processed fibers. The presence of non-notifiable substances was also observed.The most viable filters are Si filters with a pore size of 10 microns to 1 micron and the use of the selected collection and transport filter system. In the following a filter system will be applied for collection on Au membrane-coated polycarbonate filters. T2 - 5th International Conference on Human Systems Engineering and Design: Future Trends and Applications (IHSED 2023) KW - Microplastics KW - Textiles PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-624442 DO - https://doi.org/10.54941/ahfe1004132 VL - 112 SP - 212 EP - 223 PB - AHFE International AN - OPUS4-62444 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Weyrauch, Steffen A1 - Reemtsma, Thorsten A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Ruhl, Aki S. A1 - Jekel, Martin T1 - Settling Velocities of Tire and Road Wear Particles: Analyzing Finely Graded Density Fractions of Samples from a Road Simulator and a Highway Tunnel N2 - The terminal settling velocity is considered the most critical parameter determining the transport of tire and road wear particles (TRWP) in aquatic environments. Nonetheless, no respective empirical data has been reported so far. In this study, particle samples from a road simulator and a highway tunnel were investigated with a validated imaging method. Different density and size fractions of both samples were measured separately, acquiring sizes and settling velocities of more than 30,000 individual particles. In addition, tire marker polymers were analyzed for each fraction via thermal extraction desorption-gas chromatography/mass spectrometry. Finally, the acquired particle data was combined according to the fractions’ estimated tire contents in order to deduce detailed probability distributions of particle size and settling velocity for the actual TRWP from both samples. Weighted by TRWP-incorporated tire mass, median diameters of 54 and 44 μm as well as median settling velocities of 0.65 and 0.22 mm/s were found for TRWP from the road simulator and highway tunnel, respectively. This study thus provides the first ever empirical data on TRWP settling velocities in water, which can be highly valuable input for modeling the environmental transport of TRWP and for dimensioning TRWP retention systems. KW - Microplastics KW - TED-GC/MS KW - Sinking velocities KW - Transport PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635449 DO - https://doi.org/10.1021/acs.est.5c04165 SN - 0013-936X VL - 59 IS - 26 SP - 13434 EP - 13446 PB - American Chemical Society (ACS) AN - OPUS4-63544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Visileanu, Emilia A1 - Altmann, Korinna A1 - Stepa, Raluca A1 - Haiducu, Maria A1 - Miclea, Paul Tiberiu A1 - Vladu, Alina A1 - Dondea, Felicia A1 - Grosu, Marian Catalin A1 - Scarlat, Razvan T1 - Comparative Analysis of Airborne Particle Concentrations in Textile Industry Environments Throughout the Workday N2 - This paper addresses the growing concern surrounding microplastic pollution, particularly within the textile industry, and the associated potential health risks linked to the inhalation and ingestion of microplastic particles. Microplastics, defined as plastic particles smaller than five millimeters, are increasingly found not only in aquatic environments, but also in soils, air, and food. Although research on the health impacts of microplastics is still emerging, early studies indicate that these particles could contribute to health issues, including oxidative stress, inflammation, and cardiovascular diseases. Notably, individuals with higher concentrations of plastics in arterial plaques are more susceptible to heart attacks and strokes. In the textile industry, synthetic fibers such as polyester, nylon, and acrylic release microplastics into the air during production. The paper discusses a study conducted in a textile company that processes polyester yarns, where airborne microplastic concentrations were measured at various locations throughout the day. Particle sizes ranging from 0.3 nm to 10 nm were analyzed, revealing the presence of polyester polymers in the particulate matter. These findings underscore the widespread nature of microplastic pollution, particularly in industrial settings, and raise concerns about the health risks associated with prolonged exposure to airborne microplastics. While further research is necessary to fully understand the extent of these health impacts, preliminary data suggest a troubling link between microplastic inhalation and cardiovascular conditions. KW - Microplastics KW - Textiles KW - Airborne particles PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635269 DO - https://doi.org/10.3390/microplastics4020034 SN - 2673-8929 VL - 4 IS - 2 SP - 1 EP - 17 PB - MDPI AG AN - OPUS4-63526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Bednarz, Marius A1 - Braun, Ulrike A1 - Bannick, Claus Gerhard A1 - Ricking, Mathias A1 - Altmann, Korinna T1 - A promising approach to monitor microplastic masses in composts N2 - Inputs of plastic impurities into the environment via the application of fertilizers are regulated in Germany and the EU by means of ordinances. Robust and fast analytical methods are the basis of legal regulations. Currently, only macro- and large microplastic contents (>1 mm) are measured. Microplastics (1–1,000 µm), are not yet monitored. Thermal analytical methods are suitable for this purpose, which can determine the mass content and can also be operated fully automatically in routine mode. Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) allows the identification of polymers and the determination of mass contents in solid samples from natural environments. In accordance with the German or European Commission (EC) Fertiliser Ordinance, composting plants should be monitored for microplastic particles with this method in the future. In this context a compost plant was sampled. At the end of the rotting process, the compost was sieved and separated in a coarse (>1 mm) and a fine fraction (<1 mm). The fine fraction was processed using density separation comparing NaCl and NaI as possible salt alternative and screened for microplastic masses by TED-GC/MS with additional validation and quality assurance experiments. With TED-GC/MS total microplastics mass contents of 1.1–3.0 μg/mg in finished compost could be detected with polyethylene mainly. What differs much to the total mass of plastics in the coarse fraction with up to 60 μg/mg, which were visually searched, identified via ATR-FTIR and gravimetrically weighted. KW - Microplastics KW - TED-GC/MS KW - Compost KW - Monitoring KW - Soil PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-586688 DO - https://doi.org/10.3389/fenvc.2023.1281558 SN - 2673-4486 VL - 4 SP - 1 EP - 12 PB - Frontiers Media CY - Lausanne AN - OPUS4-58668 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Monikh, Fazel A. A1 - Materić, Dušan A1 - Valsami-Jones, Eugenia A1 - Grossart, Hans-Peter A1 - Altmann, Korinna A1 - Holzinger, Rupert A1 - Lynch, Iseult A1 - Stubenrauch, Jessica A1 - Peijnenburg, Willie T1 - Challenges in studying microplastics in human brain N2 - Human exposure to microplastics and nanoplastics (MNPs) is an emerging concern with potential implications for health. As awareness of this issue grows, it has prompted increasing scientific attention toward understanding if, and how, MNPs accumulate in human tissues. In a recent study, Nihart et al.1 used the analytical technique of pyrolysis gas chromatography–mass spectrometry (Py-GC–MS) to detect MNPs in human liver, kidney and brain, reporting the highest concentrations in the brain, with polyethylene as the predominant polymer. The study as reported appears to face methodological challenges, such as limited contamination controls and lack of validation steps, which May affect the reliability of the reported concentrations. In this Matters Arising, we highlight methodological limitations that have General relevance for advancing robust and reproducible MNP detection in human biomonitoring studies. KW - Microplastics KW - Nanoplastics KW - Py-GC-MS PY - 2025 DO - https://doi.org/10.1038/s41591-025-04045-3 SN - 1078-8956 VL - 31 IS - 12 SP - 1 EP - 3 PB - Springer Science and Business Media LLC AN - OPUS4-64698 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Seasonal microplastic concentrations along the rivers Rhine and Danube N2 - Over the last 20 years, many researchers, politicians and citizens have become increasingly aware of the growing plastic problem of our time. A lack of recycling concepts and plastic collection points as well as careless dumping lead to accumulation of plastic products in the environment. Natural weathering can cause these plastics to degrade and fractionate, meaning that microplastics (1 1,000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) of various synthetic polymer materials can now be detected in all parts of the world. Whether microplastics or nanoplastics pose a toxicological hazard is being investigated in a variety of ways. Valid results are still pending. However, the EU precautionary principle applies to micro- and nanoplastics. Monitoring of microplastics is already required in the revision of the Drinking Water and Wastewater Framework Directive. Reliable monitoring of rivers can be carried out by sampling with sedimentation boxes and microplastic detection by using thermal extraction desorption gas chromatography/mass spectrometry (TED-GC/MS) in routine operation (Figure 1). The river Rhine was sampled for microplastic masses at three different sampling locations over a period of one year and in addition the Danube at randomized sampling locations The TED-GC/MS results showed that various synthetic polymers frequently produced in industry, such as polyethylene, polypropylene or polystyrene as well as the tire compound styrene-butadiene rubber were found. The work not only shows a possible workflow for monitoring concepts, but also provides information on environmentally relevant concentrations of microplastics and tire components in surface waters. This in turn is necessary for ecotoxicological studies. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Polymer 3R PY - 2024 AN - OPUS4-61016 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Béalu, Zoé A1 - Walther, Johanna A1 - Abusafia, Attaallah A1 - Altmann, Korinna A1 - Meurer, Maren A1 - Gretzschel, Oliver A1 - Schäfer, Michael A1 - Steinmetz, Heidrun T1 - Removal of Organic Micropollutants and Microplastics via Ozonation Followed by Granular Activated Carbon Filtration N2 - Discharge from Wastewater Treatment Plants (WWTPs) can result in the emission of organic micropollutants (OMPs) and microplastics (MPs) into the aquatic environment. To prevent this harmful release, a pilot plant consisting of an ozonation followed by a granular activated carbon (GAC) filter was operated at a WWTP in Germany, and its side-effects on the concentrations of nitrogen (N) and phosphorous (P) compounds were measured. Over 80% of OMPs and transformation products were removed during the operating time (around 6000 bed volumes) no matter the ozone dose (from around 0.1 to 0.5 mgO3/mgDOC), except for Diatrizoic acid, whose breakthrough appeared at 3500 BV. Formation of the oxidation by-product, NDMA, increased with higher ozone doses, but the concentration remained below 100 ng/L. Bromate was formed at a higher ozone dose (0.4 mgO3/mgDOC) but at a low concentration—below 10 µg/L. The MP particles detected in the inflow (PE, SBR, PP, and PS) were effectively eliminated to a high degree, with a removal rate of at least 92%. Carbon parameters (COD, DOC, and SAC254) were removed further by the pilot plant, but to different extents. As expected, nitrate was formed during ozonation, while nitrite’s concentration decreased. Further, nitrite decreased and nitrate increased within the GAC filter, while ammonium was eliminated by at least 90%. Total P concentration decreased after the pilot, but the concentration of PO4-P increased. KW - Microplastics KW - TED-GC/MS KW - Granular Activated Carbon Filtration KW - Removal of Organic Micropollutants KW - Wastewater treatment plant PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615209 DO - https://doi.org/10.3390/environments11110241 VL - 11 IS - 11 SP - 1 EP - 38 PB - MDPI AG AN - OPUS4-61520 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, C A1 - Wiesner, Yosri A1 - Braun, U A1 - Giovannozi, A A1 - Fadda, M A1 - Putzu, Mara A1 - Lorenzo, S A1 - Moscoso-Pérez, C A1 - Benismail, N A1 - Palma, C A1 - Almeida, J A1 - Mattarozzi, M A1 - Barbaresi, M A1 - Piergiovanni, M A1 - Masino, M A1 - Bianchi, F A1 - Careri, M A1 - v Bavel, B A1 - Maltseva, A A1 - Sillanpää, M A1 - Pröfrock, D A1 - Wippermann, D A1 - Altmann, Korinna T1 - Harmonisation of sample preparation for microplastic analysis: Recovery rates of tablets containing microplastics as reference material for food and environmental matrix N2 - Microplastic are found ubiquitarians in the environment and food products. Up to now, their impact of risks on health and environment is still controversially discussed, but based on the precautionary principle alone, their presence should be monitored and emission should be reduced (see here also the status of existing EU regulations ). The crucial point is not only the reduction of microplastics pollution but also the introduction of legally binding, standardized procedures for their analysis. The limited availability of certified reference material as well as absence of standard operating procedures to identify, characterize and quantify microplastics according to number and mass have generated lack of comparability between different analytical methods and laboratories; but also, the need of time-consuming development of own protocols for each laboratory. Further on, harmonisation and standardisation of microplastics analysis requires specific reference materials that are used to validate the measurement and to ensure the comparability of results. In the first step, we developed tablets of a water-soluble matrix, containing defined numbers of microplastic particles or mass contents. These can be solved in water and can be handled as reference materials in bottled drinking water without additional sample preparation. These samples can be measured, using mass-based methods as thermo-analytical methods like thermal desorption-gas chromatography-mass spectrometry (TED-GC/MS) or pyrolysis–gas chromatography–mass spectrometry (Py-GC/MS) and using umber-based methods as vibrational spectroscopy like Infrared and Raman directly after filtration. The aim of this work was to delevop standard operating procedure to measure microplastics in more complex matrices and to harmonise and compare different detection and characterization methods. In fact, these matrices require different additional treatments to allow a reliable quantification and identification of microplastics. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics PY - 2025 AN - OPUS4-63366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Altmann, Korinna A1 - Braun, U. T1 - Determination of Microplastic Mass Content by Thermal Extraction Desorption Gas Chromatography– Mass Spectrometry N2 - The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods. Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS). KW - Microplastics KW - Mikroplastik KW - TED-GC/MS KW - Microplastics analytic KW - Mikroplastik Massegehalt PY - 2021 VL - 17 IS - 3 SP - 2 EP - 7 PB - MultiMedia (UK) LLC CY - Cranbury AN - OPUS4-52570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - PlasticTrace WP1 – Stakeholder Workshop N2 - The talk summarizes the achievments of WP1 of the PlasticTrace project. Microplastic reference materials were developed by producing tablets. Different preparation methods were compared. Characterisation of the tablets was done after filtration with µFTIR, QCL, µRaman, Py-GC/MS and TED-GC/MS after ISO standards ISO 16094-2 and ISO/FDIS 16094-3. Polymer types are polypropylene and polyethylene terephthalate. T2 - Stakeholder Workshop PlasticsTrace CY - Online meeting DA - 09.09.2025 KW - Microplastics KW - Reference materials KW - TED-GC/MS KW - PET PY - 2025 AN - OPUS4-64258 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P-T T1 - Evaluation of Toxicological Characteristics of Airborne Nano/Microplastic Particles From the Industrial Environment N2 - Micro and nano plastic (MNPs) particles and fibres represent a global scale contamination source with hazard potential. They can be identified all around our environment, even in air, soil and water. One of the major global MNPs polluters is the textile industry, which generates plastic particles (nylon, polyester, polyurethane, polyolefin, acrylic etc.) during the manufacturing processes. The study analyses the level of particle concentration outside a company that processes textile yarns, but also from the proximity of workplaces using an online air samplers with cascade and mono filter holders for silicon (Si) and quartz filters, respectively. A laser detector was used for real- time counting of particles of six size classes (PM0.3-PM10). Silicon (Si) filters with a diameter of 9 mm and pore sizes of 10 µm and 1 µm and quartz filters with a diameter of 25 mm and a pore size of 1.2 µm were used for particle sampling. A special holder was designed and made for selective sampling (PM10 and PM1.0) on Si filters. Quartz filters were pre-calcined (8000C) before collection. Sampling parameters: airflow (GilAir Plus pump) -2 l/m3, collection time -3 hours; starting time 7.00 am (T1)/2.00 pm (T2), intermittent natural ventilation, average temperature and humidity: 23.3 0C, RH: 52.5%. The weight of particles collected (µg) on the quart filters was 4.9E-05 (T1) and 5.1E-05 (T2) and on the Si filters 3,2 E-05(T1) and 5E-06(T2). The total number of the outside particles (PM0,3-PM10) was situated between 3584,58 (T1)-15165,05(T2) and inside 9901(T1) and 12921,61(T2). The highest number of PM 10 particles inside was 72/m3 and of PM0.3 particles 71979/m3. The samples were characterized using electron microscopy and µRaman spectroscopy. All samples showed a high concentration of particles on the filter. Samples show only particles with irregular shapes. The equivalent particle diameter was for PM10: 1-5 µm and PM1<1 µm. The total Ion Chromatogram shows the presence of PET-type polymer and the TED GS-MS analysis shows that the weight of the collected particles is PET. After extracting the particles from the quartz filters, they were tested for evaluation of the cytotoxic potential of preparations on human monocyte-macrophage cell cultures and peripheral lymphocytes. In the first case, the level of cytotoxicity was at the border between non-cytotoxic and cytotoxic and in the second test the result was moderate cytotoxic. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - TED-GC/MS KW - Nanoplastics KW - Raman microscopy PY - 2025 AN - OPUS4-63378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Harmonisation efforts of the CUSP projects N2 - The talk is about harmonisation approaches within CUSP. First the five H2020 projects for research on risk assessment regarding microplastics topic were presented. Secondly, harmonisation process were discussed. T2 - VAMAS SC 47 Meeting CY - Turin, Italy DA - 19.10.2022 KW - Microplastics KW - Harmonisation KW - Nanoplastics KW - H2020 KW - Risk assessment PY - 2022 AN - OPUS4-56077 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Improvements in micro- & nanoplastic mass detection by TED-GC/MS N2 - Introduction to microplastics, definition, relevance, analytical approaches & challenges. TED-GC/MS working principle, features & performance. Optimisation in TED-GC/MS methodology, new validation data. Replacement of Internal Standard, outlook towards upcoming publication and application within EU´s revised drinking water directive. T2 - SETAC 2023 CY - Dublin, Ireland DA - 01.05.2023 KW - Microplastics KW - Thermoanalytics KW - Validation KW - Internal Standard PY - 2023 AN - OPUS4-57421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Micro- and nanoplastic particle number and mass-based analysis on a plastic-free size-selective two stage Si membrane filtration cascade N2 - The poster presents a Si wafer filter development as two stage cascade and the adapter for microplastics filtration. T2 - SETAC Europe 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - Microplastics KW - Filtration KW - TED-GC/MS KW - Polymer 3R KW - Cascade filtration PY - 2023 AN - OPUS4-57461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Real-life airborne micro- and nano-plastic particles and fibres on a porous membrane filter system from a textile factory suitable for both: vibrational and mass spectrometry N2 - The poster presents an application of Si wafer filter system on indoor air sampling. A textile factory producing PP fibres was sampled. T2 - SETAC Europe 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - Microplastics KW - Polymer 3R KW - Textile fibres KW - Si wafer filter KW - Microplastics sampling PY - 2023 AN - OPUS4-57462 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rossi, A T1 - Lactose Tablets as Suitable Microplastics Reference Material to Support Validation Studies and Quality Control N2 - One of the main challenges in validating microplastics detection methods is the lack of suitable reference materials that accurately reflect the properties of interest. To bridge this gap, the EU-funded PlasticTrace project has developed water-soluble tablets containing precisely defined amounts of polyethylene terephthalate (PET) particles. Each tablet includes a specific mass (0.2, 18.5, or 400 µg) and particle count (151 or 1764, measured via Raman spectroscopy). Production follows a rigorous solid-phase dilution process, ensuring high reproducibility and quality control. The PET particles used in these tablets have an average size of approximately 40 µm, with a range between 10 and 200 µm, and an irregular, stone-like shape. All measurements align with ISO/TC 147/SC 2 standardization efforts and adhere to ISO/DIS 16094-2 and ISO/DIS 16094-3. To assess tablet homogeneity, the most widely accepted microplastics detection techniques, i.e. µ-FTIR, µ-Raman, Py-GC/MS, and TED-GC/MS, were applied. Different batches were produced, each containing varying particle numbers and masses, reaching the detection limits of the methods used. The results demonstrated excellent consistency between tablets, successfully passing homogeneity tests. Furthermore, no significant changes were observed in the tablets' composition or stability after six months of storage. This innovative reference material represents an important advancement in microplastics analysis, supporting laboratories in meeting EU Commission requirements for the monitoring of microplastics in drinking water and wastewater with greater accuracy and reliability. The production process can be transferred for other plastic particles is this size range. T2 - BERM 16 CY - Halifax, Canada DA - 01.06.2025 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Raman microscopy PY - 2025 AN - OPUS4-63403 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fernández-González, V. T1 - Innovations in Microplastic Measurement: A Pyrolysis Approach for a Polyethylene Terephthalate Reference Material N2 - In the framework of the PlasticTrace project, in which a reference material for PET microplastics will be proposed, a method using pyrolysis and gas chromatography coupled with mass spectrometry detection (Py-GC-MS) is developed to quantify the mass of PET microplastics (10-100 µm) in tablets at two different concentration levels. The overall aim of this project is to develop international metrological capacity that enables the traceable measurement and characterization of SMPs and NPs in environmental and food samples and the production of suitable reference materials, according to the metrological requirements (https://plastictrace.eu/). The proposed method consists of dissolving the tablet containing the PET microplastics in milli-Q water and filtering the solution using a glass microfiber membrane 13 mm filter size, 1.6 µm pore size. After filtering and several washes to ensure complete dissolution of the tablet and recovery of all PET microplastics, the filter is removed, folded, and placed in a capsule of the pyrolyzer for direct Py-GC/MS analysis. Two main markers were selected for PET quantification: vinyl benzoate and benzoic acid, with consistent concentrations found for both at high PET concentrations (≈400 µg) (24% RSD, n=17), but interferences with the matrix and vinyl benzoate were found at low concentrations (≈17 µg PET), with only benzoic acid being valid as a marker in this case (22% RSD, n=10). As an alternative to the quantification of PET microplastics in tablets at low concentrations, derivatization is proposed, for which tetramethylammonium hydroxide solution (TMAH) is added directly into the pyrolysis cap. The PET marker in this case is dimethyl terephthalate, with which good results have also been found (19.6% RSD, n=10 ). The proposed method is robust, simple, with high automation and very little sample handling and treatment, and allows the analysis of PET microplastics (>10 µm) in tablets with excellent accuracy and precision even at very low concentrations. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics KW - GC/MS PY - 2025 AN - OPUS4-63383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Booth, A. T1 - Production of a 1-10 μm polypropylene reference material for development of analytical methods N2 - The poster is about the preparation of microplastics in the size range of 1-10 µm. These size range of particles can be inhalded and therefore be toxic for humans. The preparation is done by comminution of PP pellets and sieving. Characterisation occured for size with laser diffraction, for type with FTIR and for shape with SEM. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials PY - 2025 AN - OPUS4-63367 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Novel laser pre-structured silicon filters for microplastics analysis N2 - This research presents a novel laser-assisted approach to silicon filter fabrication, offering an effective alternative to traditional photolithographic processes. By integrating selective femtosecond laser irradiation with photoelectrochemical etching, we achieved precisely controlled pore geometries, overcoming common challenges in filter production for microplastic and nanoscale filtration suitable for microplastic number and mass analysis. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics KW - Raman microspectroscopy PY - 2025 AN - OPUS4-63384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Putzu, Mara T1 - Optimization of production process for microplastics reference materials N2 - Microplastics (MP) are defined as plastic particles mainly consisting of polymers in the size range of 1 to 1000 µm. They can be found in a wide range of environmental matrices but also in food products, indicating a potential risk on humans and environment. Plastic debris in the environment or food chain are extremely complex in terms of size, concentration, polymer type, levels of physiochemical degradation and undefined morphologies which makes their isolation and detection in complex matrices challenging. Analytical detection methods and techniques to identify and quantify microplastics in environmental and food matrices are numerous but validated and standardized methods are currently lacking. To close this research gap, reference materials (RMs) and representative sample preparation approaches are urgently needed. Homogeneity and stability are two crucial characteristics for the certification process of the reference materials. For this purpose, we aim to present ways to prepare reference materials containing very low masses of close-to reality plastic particles with broad size distribution (10-100 µm) that are homogeneously distributed in tablet-to-tablet variation and stable over time. Our work is based on the ISO Guide 30:2015 and ISO Guide 35:2017 to fulfil the criteria set in future standards ISO/DIS 16094-2 and ISO/DIS 16094-3. The property of interest will be the mass detected by thermogravimetric analysis (TGA). Furthermore, informative values will be achieved by mass-based technique TED-GC/MS and spectroscopic microscopy techniques, such as µ-FTIR spectroscopy and µ-Raman. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials KW - TED-GC/MS PY - 2025 AN - OPUS4-63386 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, Paul T1 - Microanalysis of Airborne Nano/Microplastic Particles in an Textile Industrial Environment N2 - Micro- and nanoplastics (MNPs) are emerging global contaminants, present in air, soil, and water. The textile industry is potentially a major contributor, releasing synthetic particles like polyamide, polyester, and acrylic during production. This study assessed MNP levels outside and inside a textile-processing facility using online air samplers with silicon (Si) and quartz filters. Real-time particle counts (PM0.3–PM10) were obtained via a laser detector. Si filters (9 mm, 10/1 µm pores) and quartz filters (25 mm, 1.2 µm pores, pre-calcined at 800°C) were used for sampling. Custom holders allowed selective sampling for PM10 and PM1 on Si filters. Sampling conditions included a 3-hour collection at 2 L/min (GilAir Plus pump) starting at 7:00 AM (T1) and 2:00 PM (T2), with intermittent ventilation, 23.3 °C average temperature, and 52.5% humidity. Particle weights collected (µg) were: quartz – 4.9E-05 (T1), 5.1E-05 (T2); Si – 3.2E-05 (T1), 5E-06 (T2). Outside particle counts ranged from 3,584 (T1) to 15,165 (T2); inside: 9,901 (T1) to 12,921 (T2). Maximum indoor PM10 and PM0.3 levels were 72/m³ and 71,979/m³, respectively. Particles were analyzed using electron microscopy and µRaman spectroscopy, confirming high concentrations of irregularly shaped PP-based particles (1–5 µm). T2 - 12th TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Airborne particles KW - Raman microspectroscopy PY - 2025 AN - OPUS4-64485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Validation of microplastics detection methods and proficiency testing: Suitable microplastic reference materials for interlaboratory comparison N2 - The talk summarizes challenges in microplastic analysis. It shows the preparation of microplastic reference materials as well as the testing on homogeneity and stability. The reference material is used in an international laboratory comparison to compare different detection methods used for microplastic analysis. The methods used were µ-IR (FTIR+LDIR) for number-based methods and TED-GC/MS and Py-GC/MS for mass-based methods. The ILC was done under the umbrella of VAMAS TWA 45. Results of the participants are presented. T2 - BAM Akademie CY - Online meeting DA - 16.05.2024 KW - Microplastics KW - Reference materials KW - ILC KW - Microplastics detection KW - TED-GC/MS KW - Polymer 3R PY - 2024 AN - OPUS4-60085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Rapid sample preparation to detect microplastics in baby milk powder N2 - Microplastics, ubiquitous as it is, could be released into food during production chain, through packaging and by consumer´s use. To determinate human exposure to microplastics is crucial to monitor microplastics in food matrices. The current absence of standard sample preparation procedures to identify and quantify different microplastics according to number and mass have generate time-consuming protocols and lack of comparability among different analytical methods, laboratories and time scales. Monitoring microplastics in complex matrices as food, and in particular in baby milk powder, requires an accurate approach that need to be validate, to ensure the comparability of results. Bottled drinking water or surface waters, for example, can be measured with mass-based methods (TED-GC/MS or Py-GC/MS) directly after filtration. Baby milk powder, instead is more challenging, due to the proteins and fatty acid that clog the filters and contaminate the measuring devices with heavy carry over. In this study, we characterize the baby milk powder by thermogravimetric analysis (TGA) and we tested different treatments for matrix reduction: water, H2O2, citric acids. In particular, the use of citric acid was tested for protein reduction before filtration. Our hypothesis was that citric acid will induce the precipitation of proteins and amino acids, leading to a strong matrix reduction. In fact, this sample pre treatment, allowed us to use a higher intake, necessary for representative quantification. Finally, the milk powder was spiked with reference material tablets containing polyethylene terephthalate (PET). The PET was not degraded by the citric acid and high recovery rate was achieved by TED-GC/MS and Py-GC/MS methods. Considering the simplicity and accessibility of this sample preparation and its robust results, this procedure could be easily proposed as a simple sample preparation approach to monitor microplastics by mass-based methods. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Milk KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bauer, J. A1 - Miclea, P.-T. A1 - Braun, U. A1 - Altmann, Korinna A1 - Turek, M. A1 - Hagendorf, C. T1 - Microplastic detection and analysis in water samples N2 - Microplastic detection in water samples becomes important for tracing microplastic sources. Microplastic may harm desalination facilities by blocking filters and disturbing the marine food chain. Thermo analytical methods such as pyrolysis gas chromatography mass spectroscopy, and spectroscopic methods like (micro) Raman spectroscopy or (micro) Fouriertransform infrared spectroscopy in combination with appropriate filters and sample preparation are suitable for analyzing microplastics on a scale from 1 µm to 1000 µm fast and unambiguous. While the thermo analytical methods are suitable for larger sample volumes, Raman spectroscopy and Fouriertransform infrared spectroscopy are able to detect and analyze single microplastic particles for instance in bottled water. Machine learning algorithms ensure a reliable classification of different plastic materials. T2 - International Conference on Sustainable Energy-Water-Environment Nexus in Desert Climate 2019 CY - Ar-Rayyan, Qatar DA - 02.12.2019 KW - Microplastics KW - Water samples PY - 2022 SP - 111 EP - 113 PB - Springer AN - OPUS4-56240 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Reference material candidates for microplastic analysis N2 - Every day, there are new headlines in the media about microplastics (1-1000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) findings all over the planet with high variations in particle number and mass. The challenges in analytics are very complex, e.g. representative sampling, non-destructive sample preparation with concentrated particles and homogeneous distribution and true detection. All together lead to lacks in harmonization and results, which are hardly comparable. On the other hand, monitoring of microplastics is mandatory in the future strictly regulated by the EU commission in the Drinking water and Wastewater Framework Directive. One step to accurate and precise results will be the development of suitable reference materials mimicking particles in the environment. BAM developed test materials, which are produced by mixing a small portion of microplastic particles with a water-soluble matrix. After solid phase dilution and homogenisation small portions are pressed into tablets and bottled in glass vials (Figure 1). These tablets are well characterized with particle size distribution and SEM images. Additionally, they are tested as reference material candidate according to homogeneity and stability for particle number with µ-IR and µ-Raman as well as on particle mass with Py-GC/MS and TED-GC/MS after ISO Guide 35. Results are promising. The material passed the homogeneity control. No changes are observed within 6 months of storage. The same tested reference material is finally used in sample preparation experiments, where environmental suspended particular matter from surface water or baby milk powders are spiked with the tablets. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polymer 3R KW - Tablets PY - 2024 AN - OPUS4-61017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -