TY - CONF A1 - Marquardt, Julien T1 - Investigating the morphology of nanostructured mixed metal oxides (Ir/TiOx) and its impact on the electrocatalytic OER-activity N2 - The electrocatalytic conversion of water into molecular hydrogen and oxygen under the utilization of excess renewable energies, such as wind power, photovoltaics and hydroelectric power is one possible pathway to establish a sustainable hydrogen economy. The obtained hydrogen is either stored and used in a fuel cell or consumed on-site in industrial applications. Water electrolysis systems (WES) are based on two half cell reactions, such as oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) which both proceed simultaneously. The OER suffers from slow reaction kinetics and thus limits the overall performance. The most promising compounds in acidic electrolysis are IrO2 and RuO2. Due to their rare abundance and extremely high price a wide use of acidic WES was prevented. Lowering the catalysts noble metal content by mixing iridium with titanium reduces the production costs. Thin films are produced by dip coating a solution of metal oxide precursors alongside with a polymer template dissolved in ethanol. The obtained samples are subsequently calcined to the remove the template and adjust crystallinity. Finally, an additional iridium deposition step was performed on the outer surface plane area. Understanding the influence of structural and morphological aspects on the OER-activity is beneficial to further optimize WES. The current presentation will thus give detailed insights to structural aspects obtained by Raman spectroscopy, small- and wide-angle X-ray scattering which are then combined with electrochemical parameters to deduce structure-activity relationships. T2 - Joint Polish-German Crystallographic Meeting 2020 CY - Wrocław, Poland DA - 24.02.2020 KW - nanostructured KW - electrocatalysis PY - 2020 AN - OPUS4-50664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klöckner, P. A1 - Seiwert, B. A1 - Eisentraut, Paul A1 - Braun, Ulrike A1 - Reemtsma, T. A1 - Wagner, S. T1 - Characterization of tire and road wear particles from road runoffindicates highly dynamic particle properties N2 - Tire and road wear particles (TRWPs) are heteroagglomerates of tire rubber and other particles deposited on the road surface and one of the main contributors to non-exhaust emissions of automobile traffic. In this study, samples from road environments were analyzed for their TRWP contents and concentra- tions of eight organic tire constituents. TRWP concentrations were determined by quantifying Zn in the density fraction < 1.9 g/cm ³and by thermal extraction desorption-gas chromatography-mass spectrometry (TED-GC/MS) and the concentrations ranged from 3.7 to 480 mg TRWP/g. Strong and statistically signif- icant correlations with TRWPs were found for 2-hydroxybenzothiazole and 2-aminobenzothiazole, indi- cating that these substances may be suitable markers of TRWPs. The mass distribution of TRWPs in road dust suggests that the main mass fraction formed on roads consists of coarse particles ( > 100 μm). Data for a sedimentation basin indicate that the fine fraction ( < 50 μm) is preferentially transported by road runoffinto receiving waters. The size distribution and density data of TRWP gathered by three different quantitation approaches also suggest that aging of TRWPs leads to changes in their particle density. An improved understanding of the dynamics of TRWP properties is essential to assess the distribution and dissipation of this contaminant of emerging concern in the environment. KW - Tire Wear KW - Density separation KW - Microplastic KW - Urban PY - 2020 DO - https://doi.org/10.1016/j.watres.2020.116262 VL - 185 SP - 116262 PB - Elsevier Ltd. AN - OPUS4-51256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dittmann, Daniel T1 - Aktivkohlecharakterisierung von GAK-Filtern bei unterschiedlichen Laufzeiten N2 - Eine umfangreich ausgestaltete Trinkwasseraufbereitung als Multibarrieren-System ist notwendig, wenn das Rohwasser direkt aus Fließgewässern entnommen wird (z. B. für das Mülheimer Verfahren). Eine der Barrieren wird, als gezielte Behandlungs- oder Sicherheitsstufe, oft als Filter mit granulierter Aktivkohle (GAK-Filter) realisiert. Ihre Standzeit kann bei geringer Wasserbelastung (DOC < 2 mg/L), z. B. bei der Landeswasserversorgung Langenau, bis zu 5 Jahre betragen. Bei Rohwasser mit höherem Organikgehalt (DOC > 7 mg/L), wie bei der Nordwasser in Rostock, wird hingegen mindestens alle drei Jahre die GAK in den Filterkolonnen ausgetauscht. Die Rest-Adsorptionskapazität der GAK kann durch verschiedene Verfahren abgeschätzt werden, ist aber nach wie vor Gegenstand aktueller Forschung. Die weitergehende Charakterisierung der beladenen GAK kann hierbei helfen. Auf dem Poster sollen erste Ergebnisse zu den in Langenau und Rostock eingesetzten Aktivkohlen präsentiert werden. Hierzu wurden die frischen und nach unterschiedlichen Laufzeiten beladenen GAK untersucht. Die Zusammensetzung der Anorganik und der adsorbierten Organik, welche mittels Zersetzungs¬gasanalyse charakterisiert wurde, zeigt deutliche Unterschiede. Bspw. nimmt der Calcium-Gehalt der GAK in Langenau kontinuierlich zu, wohingegen dieser in den Proben aus Rostock mit zunehmender Laufzeit zurückgeht. Umgekehrt verhält es sich mit der Organik: Die GAK aus Rostock zeigen Hinweise auf biologische Besiedelung, während diese in Langenau trotz längerer Filterlaufzeit auszubleiben scheint. T2 - 4. Mülheimer Wasseranalytisches Seminar (MWAS2020) CY - Mülheim an der Ruhr, Germany DA - 16.09.2020 KW - Thermogravimetrie KW - Trinkwasser KW - Wasseraufbereitung KW - Aktivkohle PY - 2020 AN - OPUS4-51433 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmann, Daniel A1 - Lucke, T. A1 - Ruhl, A. S. A1 - Winzenbacher, R. A1 - Jekel, M. A1 - Braun, Ulrike T1 - Untersuchungen zu biologischen, organischen und anorganischen Veränderungen granulierter Aktivkohlen während der Trinkwasseraufbereitung N2 - Untersuchungen zu biologischen, organischen und anorganischen Veränderungen granulierter Aktivkohlen während der Trinkwasseraufbereitung des Landeswasserversorgers Langenau. KW - Thermogravimetrie KW - Trinkwasser KW - Wasseraufbereitung KW - Aktivkohle PY - 2020 SN - 0083-6915 VL - 118 IS - 2 SP - 47 EP - 50 PB - Wiley-VCH Verlag GmbH & Co. KGaA AN - OPUS4-51434 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Goedecke, Caroline A1 - Dittmann, Daniel A1 - Eisentraut, Paul A1 - Wiesner, Yosri A1 - Schartel, Bernhard A1 - Klack, Patrick A1 - Braun, Ulrike T1 - Evaluation of thermoanalytical methods equipped with evolved gas analysis for the detection of microplastic in environmental samples N2 - Microplastic particles are currently detected in almost all environmental compartments. The results of detection vary widely, as a multitude of very different methods are used with very different requirements for analytical validity. In this work four thermoanalytical methods are compared and their advantages and limitations are discussed. One of them is thermal extraction-desorption gas chromatography mass spectrometry (TED-GC/MS), an analysis method for microplastic detection that has become established in recent years. In addition, thermogravimetric analysis coupled with Fourier-transform infrared spectroscopy (TGA-FTIR) and mass spectrometry (TGA-MS) were applied, two methods that are less common in this field but are still used in other research areas. Finally, microscale combustion calorimeter (MCC) was applied, a method not yet used for microplastic detection. The presented results are taken from a recently published interlaboratory comparison test by Becker et al. (2020). Here a reference material consisting of suspended matter and specified added polymer masses was examined, and only the results of the recoveries were presented. In the present paper, however, the results for the individual polymers are discussed in detail and individual perspectives for all instruments are shown. It was found that TED-GC/MS is the most suitable method for samples with unknown matrix and unknown, variable kinds and contents of microplastic. TGA-FTIR is a robust method for samples with known matrix and with defined kinds of microplastic. TGA-MS may offer a solution for the detection of PVC particles in the future. MCC can be used as a very fast and simple screening method for the identification of a potential microplastic load of standard polymers in unknown samples. KW - Microplastic KW - TED-GC/MS KW - TGA-MS KW - TGA-FTIR KW - MCC KW - Thermal analysis PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-516687 DO - https://doi.org/10.1016/j.jaap.2020.104961 VL - 152 SP - 104961 PB - Elsevier B.V. AN - OPUS4-51668 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - Reference Materials at BAM N2 - A introduction into reference materials, the certification process and brief over current reference projects at BAM is given. T2 - AK-Postdoc seminar CY - BAM Berlin, Germany DA - 02.02.2021 KW - Referenzmaterialien KW - Reference material KW - Homogeneity KW - Stability KW - Quality testing KW - Analytic KW - DNA KW - Dosimetry KW - Certification PY - 2021 AN - OPUS4-52060 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Microplastic analysis using TED-GC/MS: H/D-Exchange of decomposition products of D-marked polystyrene as an internal standard N2 - Deuterated polystyrene (D-PS) improves microplastic detection with TED-GC / MS, among other things through higher reproducibility. It is inexpensive (0.1 ct / analysis) and can be dosed quickly and reproducibly thanks to its good solubility (e.g. in toluene). However, certain matrices lead to an exchange of the deuterium with hydrogen. The poster shows the measuring principle, in which matrices H/D-exchange takes place, the results of kinetic studies and ways of preventing or circumventing the H/D-exchange. T2 - SALSA MAKE AND MEASURE 2021 CY - Online meeting DA - 16.09.2021 KW - Microplastic KW - H/D-Exchange KW - Internal Standard KW - TED-GC/MS KW - Thermoanalytic PY - 2021 AN - OPUS4-53681 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Affinity Extraction KW - Affinity Separation KW - Protein Purification KW - Down Stream Processing KW - Antibody Purification KW - Diagnostic Antibodies KW - Therapeutic Antibodies KW - Automated Purification KW - HPLC KW - FPLC KW - IgG determination KW - Concentration step KW - Monoclonal Antibodies KW - Polyclonal Antibodies KW - Human Plasma KW - Glass Support KW - Borosilicate Glass KW - Monolith KW - Sintered Material KW - Additive Manufacturing KW - Column holder KW - Construction KW - Open Science KW - Citizen Science KW - Protein A KW - Regeneration KW - High-Speed Separations KW - Robustness PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527581 DO - https://doi.org/10.3390/separations8050056 SN - 2297-8739 N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. VL - 8 IS - 5 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-52758 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul T1 - Mikroplastikanalytik mittels TED-GC/MS: H/D-Austausch an Zersetzungsprodukten von D-markiertem Polystyrol als interner Standard N2 - Deuteriertes Polystyrol (D-PS) verbessert die Mikroplastikdetektion mit der TED-GC/MS, u.a. durch höhere Reproduzierbarkeit. Es ist kostengünstig (0,1 ct/Analyse) und durch die gute Löslichkeit (z.B. in Toluol) schnell und reproduzierbar zu dosieren. Bestimmte Matrices führen jedoch zu einem Austausch des Deuteriums durchWasserstoff. Das Poster zeigt das Messprinzip, bei welchen Matrices H/D-Austausch erfolgt, Ergebnisse von Kinetikuntersuchungen sowie Möglichkeiten, den Austausch zu verhindern oder zu umgehen. T2 - Tagung der Wasserchemischen Gesellschaft CY - Online Meeting DA - 10.05.2021 KW - Mikroplastik KW - Analyse KW - Interner Standard KW - H/D-Austausch PY - 2021 AN - OPUS4-52727 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - DNA based Reference Materials: In Biodosimetry and Pharmaceutical Quality Control N2 - Applications of plasmid DNA base reference materials in dosimetry and pharmaceutical research. T2 - Physical and Chemical Analysis of Polymers seminar CY - Online meeting DA - 29.03.2021 KW - Analytic KW - Certification KW - DNA KW - Dosimetry KW - Homogeneity KW - Quality testing KW - Reference material KW - Referenzmaterialien KW - Stability KW - Dose KW - Radiation KW - Pharmacy KW - Electrohpresis PY - 2021 AN - OPUS4-52361 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Altmann, Korinna A1 - Braun, U. T1 - Determination of Microplastic Mass Content by Thermal Extraction Desorption Gas Chromatography– Mass Spectrometry N2 - The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods. Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS). KW - Microplastics KW - Mikroplastik KW - TED-GC/MS KW - Microplastics analytic KW - Mikroplastik Massegehalt PY - 2021 VL - 17 IS - 3 SP - 2 EP - 7 PB - MultiMedia (UK) LLC CY - Cranbury AN - OPUS4-52570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Ponader, Marco A1 - Röder, Bettina A1 - Paul, Martin A1 - Weller, Michael G. T1 - Sintered glass monoliths as new supports for affinity columns N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 minute. Due to the glass material's excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nanofiltration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run. KW - Affinity Chromatography KW - Glass KW - Purification KW - Antibodies KW - Solid support KW - HPLC KW - FPLC KW - Separation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529117 DO - https://doi.org/10.20944/preprints202103.0298.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 EP - 17 PB - MDPI CY - Basel AN - OPUS4-52911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Casali, C. A1 - Feiler, Torvid A1 - Heilmann, Maria A1 - Braga, D. A1 - Emmerling, Franziska A1 - Grepioni, F. T1 - Too much water? Not enough? In situ monitoring of the mechanochemical reaction of copper salts with dicyandiamide N2 - n situ monitoring of mechanochemical reactions between dicyandiamide (DCD) and CuX2 salts (X = Cl−, NO3−), for the preparation of compounds of agrochemical interest, showed the appearance of a number of phases. It is demonstrated that milling conditions, such as the amount of water added in wet grinding and/or the milling frequency, may affect the course of the mechanochemical reactions, and drive the reaction towards the formation of different products. It has been possible to discover by in situ monitored experiments two novel crystalline forms, namely the neutral complexes [Cu(DCD)2(OH2)2(NO3)2] (2) and [Cu(DCD)2(OH2)Cl2]·H2O (4), in addition to the previously known molecular salt [Cu(DCD)2(OH2)2][NO3]2·2H2O (1, DIVWAG) and neutral complex [Cu(DCD)2(OH2)Cl2] (3, AQCYCU), for which no synthesis conditions were available. Compounds 2 and 4 were fully characterized via a combination of solid-state techniques, including X-ray diffraction, Raman spectroscopy and TGA. KW - Mechanochemistry KW - In situ PY - 2022 DO - https://doi.org/10.1039/d1ce01670a VL - 24 IS - 6 SP - 1292 EP - 1298 PB - RSC AN - OPUS4-54344 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Frisch, M. A1 - Raza, M. H. A1 - Ye, M.-Y. A1 - Sachse, René A1 - Paul, B. A1 - Gunder, R. A1 - Pinna, N. A1 - Kraehnert, R. T1 - ALD-coated mesoporous iridium-titanium mixed oxides: Maximizing iridium utilization for an outstanding OER performance N2 - With the increasing production of renewable energy and concomitant depletion of fossil resources, the demand for efficient water splitting electrocatalysts continues to grow. Iridium (Ir) and iridium oxides (IrOₓ) are currently the most promising candidates for an efficient oxygen evolution reaction (OER) in acidic medium, which remains the bottleneck in water electrolysis. Yet, the extremely high costs for Ir hamper a widespread production of hydrogen (H₂) on an industrial scale. Herein, the authors report a concept for the synthesis of electrode coatings with template-controlled mesoporosity surface-modified with highly active Ir species. The improved utilization of noble metal species relies on the synthesis of soft-templated metal oxide supports and a subsequent shape-conformal deposition of Ir species via atomic layer deposition (ALD) at two different reaction temperatures. The study reveals that a minimum Ir content in the mesoporous titania-based support is mandatory to provide a sufficient electrical bulk conductivity. After ALD, a significantly enhanced OER activity results in dependency of the ALD cycle number and temperature. The most active developed electrocatalyst film achieves an outstanding mass-specific activity of 2622 mA mg(Ir)⁻¹ at 1.60 V(RHE) in a rotating-disc electrode (RDE) setup at 25 °C using 0.5 m H₂SO₄ as a supporting electrolyte. KW - Acidic oxygen evolution reaction KW - Atomic layer deposition KW - Electrocatalysis KW - Iridium oxide KW - Soft-templated mesoporous films PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542651 DO - https://doi.org/10.1002/admi.202102035 SN - 2196-7350 SP - 1 EP - 11 PB - Wiley-VCH CY - Weinheim AN - OPUS4-54265 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eisentraut, Paul A1 - Altmann, Korinna T1 - Repräsentative Mikroplastik-Detektion in Umweltproben - Weiterentwicklung der TED-GC/MS N2 - Die große Herausforderung in der Detektion von Mikroplastik (MP)‑Partikeln (1-1000 µm) besteht darin, sie neben Millionen von natürlichen Partikeln in Umweltproben nachzuweisen. Zum Aufspüren von Senken, Eintragspfaden und für Monitoring-Kampagnen ist ein schnelles, automatisiertes Verfahren unerlässlich. Ein solches Verfahren wurde an der Bundesanstalt für Materialforschung und -prüfung (BAM) mit der ThermoExtraktion/Desorption-Gaschromatographie-Massenspektrometrie (TED-GC/MS) in den letzten Jahren entwickelt. KW - Mikroplastik KW - TED-GC/MS PY - 2021 UR - https://analyticalscience.wiley.com/do/10.1002/was.0004000195 SN - 0016-3538 SP - 2 EP - 5 PB - Wiley-VCH CY - Weinheim AN - OPUS4-54266 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kittner, Maria A1 - Kerndorff, A. A1 - Ricking, M. A1 - Bednarz, M. A1 - Obermaier, N. A1 - Lukas, M. A1 - Asenova, M. A1 - Bordós, G. A1 - Eisentraut, Paul A1 - Hohenblum, P. A1 - Hudcova, H. A1 - Humer, F. A1 - István, T. G. A1 - Kirchner, M. A1 - Marushevska, O. A1 - Nemejcová, D. A1 - Oswald, P. A1 - Paunovic, M. A1 - Sengl, M. A1 - Slobodnik, J. A1 - Spanowsky, K. A1 - Tudorache, M. A1 - Wagensonner, H. A1 - Liska, I. A1 - Braun, U. A1 - Bannick, C. G. T1 - Microplastics in the Danube River Basin: A First Comprehensive Screening with a Harmonized Analytical Approach N2 - In this study, carried out within the Joint Danube Survey 4, a comprehensive microplastic screening in the water column within a large European river basin from its source to estuary, including major tributaries, was realized. The objective was to develop principles of a systematic and practicable microplastic monitoring strategy using sedimentation boxes for collection of suspended particulate matter followed by its subsequent analysis using thermal extraction desorption-gas chromatography/mass spectrometry. In total, 18 sampling sites in the Danube River Basin were investigated. The obtained suspended particulate matter samples were subdivided into the fractions of >100 μm and <100 μm and subsequently analyzed for microplastic mass contents. The results showed that microplastics were detected in all samples, with polyethylene being the predominant polymer with maximum contents of 22.24 μg/mg, 3.23 μg/mg for polystyrene, 1.03 μg/mg for styrene-butadiene-rubber, and 0.45 μg/mg for polypropylene. Further, polymers such as different sorts of polyester, polyacrylates, polylactide, and natural rubber were not detected or below the detection limit. Additional investigations on possible interference of polyethylene signals by algae-derived fatty acids were assessed. In the context of targeted monitoring, repeated measurements provide more certainty in the interpretation of the results for the individual sites. Nevertheless, it can be stated that the chosen approach using an integrative sampling and determination of total plastic content proved to be successful. KW - Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS), monitoring KW - Microplastics KW - River KW - Suspended particulate matter (SPM) KW - Sedimentation box (SB) PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-551444 DO - https://doi.org/10.1021/acsestwater.1c00439 VL - 2 IS - 7 SP - 1174 EP - 1181 PB - ACS Publications AN - OPUS4-55144 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Röder, Bettina A1 - Gande, S. L. A1 - Sreeramulu, S. A1 - Saxena, K. A1 - Richter, C. A1 - Schwalbe, H. A1 - Swart, C. A1 - Weller, Michael G. T1 - Chemiluminescence biosensor for the determination of cardiac troponin I (cTnI) N2 - Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases. N2 - Das kardiale Troponin I (cTnI) ist ein wichtiger Biomarker für die Diagnose von Herz-Kreislauf-Erkrankungen, einschließlich des akuten Myokardinfarkts (AMI). In dieser Studie wird ein auf Chemilumineszenz basierender Immunsensor für die schnelle und genaue Messung von cTnI vorgestellt, der das Potenzial für eine Online-Überwachung hat. Der Immunsensor besteht aus einer Durchflusszelle und einer empfindlichen CMOS-Kamera (Complementary Metal-Oxide-Semiconductor) zur optischen Detektion. Es wurde ein mikrofluidischer Aufbau entwickelt, der eine selektive und quasi Online-Bestimmung von cTnI innerhalb von zehn Minuten ermöglicht. Der Sensor wurde mit rekombinantem cTnI in Phosphatpuffer getestet und zeigte einen Messbereich von 2-25 µg/L, wobei mit dem optimierten System eine Nachweisgrenze (LoD) von 0,6 µg/L (23 pmol/L) erreicht wurde. Der Immunsensor zeigte eine hohe Selektivität, da keine Kreuzreaktivität mit anderen rekombinanten Proteinen wie cTnT und cTnC bei einer Konzentration von 16 µg/L beobachtet wurde. Messungen mit verdünntem Blutplasma und Serum ergaben einen LoD von 60 µg/L (2,4 nmol/L) bzw. 70 µg/L (2,9 nmol/L). Dieser Biosensor bietet einen vielversprechenden Ansatz für den schnellen und empfindlichen Nachweis von cTnI, der zur Diagnose und Behandlung des akuten Myokardinfarkts und anderer kardialer Gefäßerkrankungen beitragen kann. KW - Acute myocardial infarction KW - Heart attack KW - Emergency KW - Diagnosis KW - Cardiac troponin KW - Biomarker KW - Immunosensor KW - Biosensor KW - Chemiluminescence KW - Luminol KW - Peroxidase KW - Monoclonal antibodies KW - Flow injection immunoassay KW - Immunometric assay KW - Immunometric biosensor KW - Microfluidic system KW - Monolithic column KW - Online biosensor PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575471 DO - https://doi.org/10.3390/bios13040455 SN - 2079-6374 VL - 13 IS - 4 SP - 1 EP - 20 PB - MDPI CY - Basel AN - OPUS4-57547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard T1 - Trinamic TMCL IOC for exposing Trinamics motor controllers to EPICS CA N2 - Trinamic TMCL IOC is a Python package designed for controlling stepper motors connected to a Trinamic board using the TMCL language (all boards supported by PyTrinamic should now work, has been tested on the TMCM 6110 and the TMCM 6214). Since it is implementing the TMCL protocol, it should be easy to adapt to other Trinamic motor controller boards. This package assumes the motor controller is connected over a machine network via a network-to-serial converter, but the underlying PyTrinamic package allows for other connections too. This allows the control of attached motors via the EPICS Channel-Access virtual communications bus. If EPICS is not desired, plain Pythonic control via motion_control should also be possible. An example for this will be provided in the example.ipynb Jupyter notebook. This package leverages Caproto for EPICS IOCs and a modified PyTrinamic library for the motor board control, and interfaces between the two via an internal set of dataclasses. Configuration for the motors and boards are loaded from YAML files (see tests/testdata/example_config.yaml). The modifications to PyTrinamic involved extending their library with a socket interface. This was a minor modification that should eventually find its way into the official package (a pull request has been submitted). KW - Instrumentation KW - Motor controller KW - EPICS KW - Channel access KW - Instrument control KW - Laboratory automation PY - 2024 DO - https://doi.org/10.5281/zenodo.10792593 PB - Zenodo CY - Geneva AN - OPUS4-59624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dalgic, Mete-Sungur T1 - Lösemittelfreie Probenpräparation zur Untersuchung von Polymerblends mittels MALDI-TOF MS N2 - Die Probenpräparation ist ein wichtiger Schritt für die Qualität der Massenspektren in MALDI-TOF MS. Es werden Polymerproben, die lösungsmittelbasiert und lösungsmittelfrei präpariert worden sind, verglichen. Dabei werden die Intensitätsverhältnisse von ternären Mischungen von PEG-, PS- und PMMA-Polymeren beachtet. T2 - 28. Kolloquium - Massenspektrometrische Techniken zur Untersuchung synthetischer Polymere CY - Berlin, Germany DA - 14.05.2024 KW - Polymere KW - Massenspektrometrie KW - Probenpräparation PY - 2024 AN - OPUS4-60032 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dalgic, Mete-Sungur T1 - Discrimination effects in MALDI-MS of Ternary Polymer Mixtures N2 - MALDI-TOF MS is a viable method to determine molecular weights of polymers. However, quantification using MALDI-TOF MS presents specific challenges due to intensity biases caused by instrumental and sample-specific parameters. In this presentation, the influence of molar masses on MALDI-TOF mass spectra is explored. The intensities of a ternary PMMA blend with different mixture ratios are depicted in contour plots. T2 - SALSA Make and Measure 2022 CY - Berlin, Germany DA - 15.09.2022 KW - MALDI-TOF MS KW - Ternary polymer blends KW - PMMA PY - 2022 AN - OPUS4-62212 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dalgic, Mete-Sungur T1 - Einfluss der Konformation auf das Ionisationsverhalten in MALDI-TOF MS N2 - MALDI-TOF Massenspektrometrie ist eine wichtige Methode zur Bestimmung von Molekulargewichten von Polymeren. Jedoch wird die quantitative Analyse von Polymeren durch verschiedene Faktoren erschwert. In dieser Präsentation wird unter anderem der Einfluss der molaren Massen auf die Massenspektren näher betrachtet. Dabei werden Konturplots von ternären PMMA- und PS-Mischungen gezeigt. T2 - 27. Kolloquium - Massenspetrometrische von Polymeren CY - Berlin, Germany DA - 09.05.2023 KW - MALDI-TOF MS KW - Ternäre Polymermischungen KW - PMMA und PS PY - 2023 AN - OPUS4-62214 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Cakir, Cafer Tufan T1 - Enhancing the Efficiency and Accessibility of Grazing Exit X-ray Absorption Spectroscopy for Corrosion and Layered Materials Analysis N2 - In the field of materials science, there is a critical need for efficient and effective characterization techniques, especially in the investigation of corrosion processes of compositionally complex alloys (CCAs) or the analysis of layered structures. This talk presents an advanced approach that combines grazing-exit X-ray absorption near-edge structure spectroscopy (GE-XANES) with Bayesian optimization (BO) to significantly improve the efficiency of data acquisition while retaining the depth-resolved, element-specific analysis capabilities that are critical for studying these materials under ambient conditions. Using a non-destructive, scan-free GE-XANES setup coupled with a pnCCD detector and grazing exit X-ray fluorescence spectroscopy (GE-XRF) geometry, our method enables precise analysis at sub-micrometer depths without the need for high vacuum environments or extensive sample preparation. The integration of BO reduces experimental time by a factor of 50, overcoming the practical limitations of conventional GE-XANES and increasing its applicability in the study of surface catalysis and corrosion processes. We validate this optimized approach through comparative studies on a CrCoNi alloy and a reference layered sample, demonstrating its potential to revolutionize materials analysis by increasing both efficiency and accessibility. T2 - Gesellschaft Deutscher Chemiker (GDCh) CY - Clausthal-Zellerfeld, Germany DA - 20.06.2024 KW - GEXRF KW - GEXANE KW - ML PY - 2024 AN - OPUS4-61788 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Li, Yue A1 - Colnaghi, Timoteo A1 - Gong, Yilun A1 - Zhang, Huaide A1 - Yu, Yuan A1 - Wei, Ye A1 - Gan, Bin A1 - Song, Min A1 - Marek, Andreas A1 - Rampp, Markus A1 - Zhang, Siyuan A1 - Pei, Zongrui A1 - Wuttig, Matthias A1 - Ghosh, Sheuly A1 - Körmann, Fritz A1 - Neugebauer, Jörg A1 - Wang, Zhangwei A1 - Gault, Baptiste T1 - Machine learning‐enabled tomographic imaging of chemical short‐range atomic ordering N2 - In solids, chemical short‐range order (CSRO) refers to the self‐organization of atoms of certain species occupying specific crystal sites. CSRO is increasingly being envisaged as a lever to tailor the mechanical and functional properties of materials. Yet quantitative relationships between properties and the morphology, number density, and atomic configurations of CSRO domains remain elusive. Herein, it is showcased how machine learning‐enhanced atom probe tomography (APT) can mine the near‐atomically resolved APT data and jointly exploit the technique's high elemental sensitivity to provide a 3D quantitative analysis of CSRO in a CoCrNi medium‐entropy alloy. Multiple CSRO configurations are revealed, with their formation supported by state‐of‐the‐art Monte‐Carlo simulations. Quantitative analysis of these CSROs allows establishing relationships between processing parameters and physical properties. The unambiguous characterization of CSRO will help refine strategies for designing advanced materials by manipulating atomic‐scale architectures. KW - Chemical short-range order (CSRO) KW - Atom probe tomography (APT) KW - Machine learning PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-623777 DO - https://doi.org/10.1002/adma.202407564 SN - 1521-4095 VL - 36 IS - 44 SP - 1 EP - 9 PB - Wiley-VCH CY - Weinheim AN - OPUS4-62377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - The Dark Side of Science (2024 edition) N2 - This presentation highlights ongoing scientific misconduct as found in academic literature. This includes data- and image manipulation, and paper mills. Starting with an expose of examples, it delves deeper into the causes and metrics driving this phenomenon. Finally a range of possible tools is presented, that the young researcher can use to prevent themselves from sliding into the dark scientific methods. T2 - Winter School on Metrology and Nanomaterials for Clean Energy CY - Claviere, Italy DA - 28.01.2024 KW - Scientific misconduct KW - Data manipulation KW - Image manipulation KW - Paper mills KW - Causes leading to scientific misconduct KW - Tools to combat scientific misconduct KW - Metrics PY - 2024 AN - OPUS4-59622 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Glimpses of the future: Systematic investigations of 1200 mofs using a highly automated, full-stack materials research laboratory N2 - By automatically recording as much information as possible in automated laboratory setups, reproducibility and traceability of experiments are vastly improved. This presentation shows what such an approach means for the quality of experiments in an X-ray scattering laboratory and an automated synthesis set-up. T2 - Winter School on Metrology and Nanomaterials for Clean Energy CY - Claviere, Italy DA - 28.01.2024 KW - Digitalization KW - Automation KW - Digital laboratory KW - Scattering KW - Synthesis KW - Nanomaterials KW - Holistic science PY - 2024 AN - OPUS4-59621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Smales, G. J. T1 - DACHS-MOFs Database for Automation, Characterisation, and Holistic Synthesis N2 - The DACHS (Database for Automation, Characterization and Holistic Synthesis) project aims to create completely traceable experimental data, covering syntheses, measurements, analyses, and interpretations. DACHS MOFs focuses on the synthesis and characterisation of metal-organic frameworks (MOFs), across multiple, automation-assisted experimental series (AutoMOFs), with the overall goal of producing reproducible MOF syntheses. So far > 1200 MOF samples have been synthesised, with SAXS/WAXS data currently being collected on all samples. All results, including those from “failed” syntheses, are included in the database, as results are results and should be considered agnostic to any positive ornegative interpretations. DACHS MOFs represents the initial trial of the DACHS project, serving as a comprehensive resource for researchers aiming to optimize the synthesis and characterization of MOFs. T2 - XIX International Small Angle Scattering Conference CY - Taipei, Taiwan DA - 04.11.2024 KW - Lab automation KW - Synthesis KW - Metal organic frameworks KW - Zif-8 KW - Databases KW - Synthesis data PY - 2024 AN - OPUS4-61626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Sweetening the (microplastics) pill: PET tablets (1-100µm) as candidate reference material for the validation of microplastics measurement N2 - The lack of validation and standard procedures in microplastics studies has led to the inability to compare and harmonise data from different analytical methods, laboratories and time scales. To monitor and regulate exposure to microplastics in the environment and in food for human health, it is crucial to ensure their comparability and to validate the analytical methods used in microplastics studies. Monitoring microplastics requires complex approaches for accurate determination otherwise it can lead to an over- or underestimation in environmental and food-relevant matrices. Moreover, to support the need of reliable measurement required by the European legislation directive on drinking water (EU 2020/2184) or the revision of the urban waste water directive, which will be finalised in 2024 the production and validation of polymeric reference materials with environmentally relevant concentrations, irregular shapes, defined aging status and different sizes is essential. The production of reference material with acceptable uncertainties in homogeneity need to be balanced, considering the low microplastics concentrations detected in the environment and in food. The aim of the project PLASTICTRACE and of this study, is to propose a “easy-to-use PET tablet ” (PET particle size mainly 1-100 µm) for routine applications as a candidate general reference material for detection methods. Batches of water-soluble matrix containing different concentrations of PET powder were produced. Results of imaging and counting methods (SEM, Laser diffraction), including production´s challenges; together with thermo-analytical methods (TED-GC/MS and Py-GC/MS) and vibrational spectroscopy (µ-Raman and µ-FTIR), will be presented. These data are useful to assess homogeneity and stability of the particles over time according to ISO 33405:2024. In addition, we will show some insights on the application of the PET-tablets in complex matrices, as milk powder and suspended solid from surface water, that could be easily used for routine microplastics analysis. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Reference materials KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Small-angle scattering for everyone: How to unlock the power of this ancient technique N2 - The obscure, yet fundamental technique of scattering can unlock essential information on the fine structure of materials. For you, it can help you understand how your batteries charge, how squid backbones work, or how hundreds of small variations in your syntheses affect your samples. As a nondestructive technique, it also measures your materials *in situ* or operando, as you pull it, heat it, electrify it, or align it one way or another. Scattering can be done using light, X-rays, neutrons, and even electrons, giving you the choice on which probe is best for you. The only downside? Scattering will always remain a complicated technique to do right. The technique gives you only one piece of information: the length distribution of density in your sample. How you interpret this (rather abstract) piece of information is up to you and your samples. Unlike microscopy, where the real-space image can be interpreted almost intuitively and artefacts are easier to spot, in scattering you cannot always easily identify artefacts. Therefore, the only way to do scattering experiments correctly is through rigour and care. For those of us with that particular eccentricity, seeing the rigour and care pay off is exhilarating, and opens the door to a life of happiness and excitement. This lecture will introduce scattering (in particular using X-rays and neutrons), what it is, what you can (and cannot) get out of it, and how to approach your scattering experiment. Regarding the experimental section, it will discuss the five parts that make up a successful scattering experiment based on real-life examples: Preparation: which and how you prepare your samples affects what you can get out of the interpretation Measurement: The machine design and your measurement choices dictates the final quality of your data Correction: Obtaining trustworthy scattering curves will greatly improve the speed and quality of your analysis. Analysis: Do you linearize, use generic scattering models, perform classical least-squares fitting, play with Monte-Carlo analysis or transform your data.. Some tips to help you make a choice. Interpretation: what does the analysis of all your samples tell you? Can you fit the puzzle pieces together to form a piece of knowledge? For further information, please feel free to explore the https://lookingatnothing.com/ weblog, the https://youtube.com/drheaddamage video channel, or by asking me in person or by email for specific questions at brian.pauw@bam.de . Some introductory reading can be found in the following papers: Pauw, B. R. (2013): Everything SAXS: small-angle scattering pattern collection and correction. _J. Phys.: Condens. Matter_ 25: 383201. DOI: [10.1088/0953-8984/25/38/383201](http://dx.doi.org/10.1088/0953-8984/25/38/383201) B. R. Pauw, A. J. Smith, T. Snow, N. J. Terrill, A. F. Thünemann, (2017): The modular SAXS data correction sequence for solids and dispersions, _Journal of Applied Crystallography_, 50: 1800–1811, DOI: [10.1107/S1600576717015096](https://doi.org/10.1107/S1600576717015096) G. J. Smales, B. R. Pauw (2021): The MOUSE project: a meticulous approach for obtaining traceable, wide-range X-ray scattering information. _Journal of instrumentation_ 16 (6) P06034. DOI: [10.1088/1748-0221/16/06/P06034](https://doi.org/10.1088/1748-0221/16/06/P06034) T2 - SAS School at the XIX International Small Angle Scattering Conference CY - Taipei, Taiwan DA - 02.11.2024 KW - X-ray scattering KW - Neutron scattering KW - Scattering KW - X-ray KW - Neutron KW - Introduction KW - Methodology PY - 2024 AN - OPUS4-61623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Chasing perfection: A holistic approach to materials science scattering experiments N2 - The materials scientists we work with do not want (or need) to learn the ways of the scatterer; they are primarily interested in obtaining trustworthy answers. In particular, they need structural understanding in light of the wider framework of their experiment(s). Our interest, therefore, lies in helping them attain this this interconnected understanding, while using such investigations to further hone our methodology to approximate perfection. While perfection is by definition an unattainable goal, we have spent the last 15+ years exploring and expanding on many of its constituent aspects (often together with likeminded people) [1]. These aspects include: - developing various visualization and simulation tools, - deconstructing data corrections and uncertainty estimation, - advancing analysis methods, - quantifying questions on traceability, documentation, - reproducible automation of synthesis-, measurement- and data pipelines, - data visualization, exploration and education, - and many more… T2 - XIX International Small Angle Scattering Conference CY - Taipei, Taiwan DA - 04.11.2024 KW - Methodology KW - X-ray scattering KW - Data quality KW - Data provenance KW - Data stewardship KW - Lab automation KW - Perfection PY - 2024 AN - OPUS4-61625 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Axel A1 - Altmann, Korinna A1 - Kocher, B. A1 - Braun, U. T1 - Determination of tire wear markers in soil samples and their distribution in a roadside soil N2 - Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed. TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance. The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation. KW - Microplastic KW - TED-GC/MS KW - Tire wear PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-543344 DO - https://doi.org/10.1016/j.chemosphere.2022.133653 VL - 294 SP - 1 EP - 8 PB - Elsevier Ltd. AN - OPUS4-54334 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drexel, R. T1 - Nano-sized Polypropylene as a Promising Candidate Reference Material: Preparation, Characterization and Stability in Complex Matrices N2 - The lack of nanoplastic (NPs) reference materials capable of mimicking real-world scenarios is currently hampering the development of validated extraction techniques from complex matrices (e.g. soils, sediments, biota), the development of analytical approaches for robust identification and quantification, and the ability to use environmentally relevant test materials in (eco)toxicity testing and hazard assessment [1]. The large body of available data suggests that larger microplastics (MPs) in the natural environment are irregular shaped, partially degraded (chemically and physically), a continuum of sizes, shapes and densities, represent a wide range of polymer types, and acts as a reservoir for thousands of plastic chemicals. Although NPs have been described as being neither MPs nor engineered nanoparticles [2], and while direct measurement data of true NP in the environment remain elusive, they are expected to be as equally diverse as MPs [3]. Here, we present a strategy towards the development of a potential NP reference material based on nano-sized polyproplyene particles (nanoPP) developed within the EURAMET-funded PlasticTrace project (https://plastictrace.eu/). The strategy includes the preparation, the physicochemical characterization and the stability assessment of nanoPP in suspension both in its pristine state, but also when spiked into food (mineral water and milk) and environmental matrices (suspended particulate matter collected from the river Elbe ). Collected experimental data suggests nanoPP to be a promising candidate for a NP reference material. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Nanoplastics KW - Reference materials PY - 2025 AN - OPUS4-63382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, C A1 - Wiesner, Yosri A1 - Braun, U A1 - Giovannozi, A A1 - Fadda, M A1 - Putzu, Mara A1 - Lorenzo, S A1 - Moscoso-Pérez, C A1 - Benismail, N A1 - Palma, C A1 - Almeida, J A1 - Mattarozzi, M A1 - Barbaresi, M A1 - Piergiovanni, M A1 - Masino, M A1 - Bianchi, F A1 - Careri, M A1 - v Bavel, B A1 - Maltseva, A A1 - Sillanpää, M A1 - Pröfrock, D A1 - Wippermann, D A1 - Altmann, Korinna T1 - Harmonisation of sample preparation for microplastic analysis: Recovery rates of tablets containing microplastics as reference material for food and environmental matrix N2 - Microplastic are found ubiquitarians in the environment and food products. Up to now, their impact of risks on health and environment is still controversially discussed, but based on the precautionary principle alone, their presence should be monitored and emission should be reduced (see here also the status of existing EU regulations ). The crucial point is not only the reduction of microplastics pollution but also the introduction of legally binding, standardized procedures for their analysis. The limited availability of certified reference material as well as absence of standard operating procedures to identify, characterize and quantify microplastics according to number and mass have generated lack of comparability between different analytical methods and laboratories; but also, the need of time-consuming development of own protocols for each laboratory. Further on, harmonisation and standardisation of microplastics analysis requires specific reference materials that are used to validate the measurement and to ensure the comparability of results. In the first step, we developed tablets of a water-soluble matrix, containing defined numbers of microplastic particles or mass contents. These can be solved in water and can be handled as reference materials in bottled drinking water without additional sample preparation. These samples can be measured, using mass-based methods as thermo-analytical methods like thermal desorption-gas chromatography-mass spectrometry (TED-GC/MS) or pyrolysis–gas chromatography–mass spectrometry (Py-GC/MS) and using umber-based methods as vibrational spectroscopy like Infrared and Raman directly after filtration. The aim of this work was to delevop standard operating procedure to measure microplastics in more complex matrices and to harmonise and compare different detection and characterization methods. In fact, these matrices require different additional treatments to allow a reliable quantification and identification of microplastics. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics PY - 2025 AN - OPUS4-63366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fernández-González, V. T1 - Innovations in Microplastic Measurement: A Pyrolysis Approach for a Polyethylene Terephthalate Reference Material N2 - In the framework of the PlasticTrace project, in which a reference material for PET microplastics will be proposed, a method using pyrolysis and gas chromatography coupled with mass spectrometry detection (Py-GC-MS) is developed to quantify the mass of PET microplastics (10-100 µm) in tablets at two different concentration levels. The overall aim of this project is to develop international metrological capacity that enables the traceable measurement and characterization of SMPs and NPs in environmental and food samples and the production of suitable reference materials, according to the metrological requirements (https://plastictrace.eu/). The proposed method consists of dissolving the tablet containing the PET microplastics in milli-Q water and filtering the solution using a glass microfiber membrane 13 mm filter size, 1.6 µm pore size. After filtering and several washes to ensure complete dissolution of the tablet and recovery of all PET microplastics, the filter is removed, folded, and placed in a capsule of the pyrolyzer for direct Py-GC/MS analysis. Two main markers were selected for PET quantification: vinyl benzoate and benzoic acid, with consistent concentrations found for both at high PET concentrations (≈400 µg) (24% RSD, n=17), but interferences with the matrix and vinyl benzoate were found at low concentrations (≈17 µg PET), with only benzoic acid being valid as a marker in this case (22% RSD, n=10). As an alternative to the quantification of PET microplastics in tablets at low concentrations, derivatization is proposed, for which tetramethylammonium hydroxide solution (TMAH) is added directly into the pyrolysis cap. The PET marker in this case is dimethyl terephthalate, with which good results have also been found (19.6% RSD, n=10 ). The proposed method is robust, simple, with high automation and very little sample handling and treatment, and allows the analysis of PET microplastics (>10 µm) in tablets with excellent accuracy and precision even at very low concentrations. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics KW - GC/MS PY - 2025 AN - OPUS4-63383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Booth, A. T1 - Production of a 1-10 μm polypropylene reference material for development of analytical methods N2 - The poster is about the preparation of microplastics in the size range of 1-10 µm. These size range of particles can be inhalded and therefore be toxic for humans. The preparation is done by comminution of PP pellets and sieving. Characterisation occured for size with laser diffraction, for type with FTIR and for shape with SEM. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials PY - 2025 AN - OPUS4-63367 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Putzu, Mara T1 - Optimization of production process for microplastics reference materials N2 - Microplastics (MP) are defined as plastic particles mainly consisting of polymers in the size range of 1 to 1000 µm. They can be found in a wide range of environmental matrices but also in food products, indicating a potential risk on humans and environment. Plastic debris in the environment or food chain are extremely complex in terms of size, concentration, polymer type, levels of physiochemical degradation and undefined morphologies which makes their isolation and detection in complex matrices challenging. Analytical detection methods and techniques to identify and quantify microplastics in environmental and food matrices are numerous but validated and standardized methods are currently lacking. To close this research gap, reference materials (RMs) and representative sample preparation approaches are urgently needed. Homogeneity and stability are two crucial characteristics for the certification process of the reference materials. For this purpose, we aim to present ways to prepare reference materials containing very low masses of close-to reality plastic particles with broad size distribution (10-100 µm) that are homogeneously distributed in tablet-to-tablet variation and stable over time. Our work is based on the ISO Guide 30:2015 and ISO Guide 35:2017 to fulfil the criteria set in future standards ISO/DIS 16094-2 and ISO/DIS 16094-3. The property of interest will be the mass detected by thermogravimetric analysis (TGA). Furthermore, informative values will be achieved by mass-based technique TED-GC/MS and spectroscopic microscopy techniques, such as µ-FTIR spectroscopy and µ-Raman. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Reference materials KW - TED-GC/MS PY - 2025 AN - OPUS4-63386 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Weyrauch, Steffen A1 - Reemtsma, Thorsten A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Ruhl, Aki S. A1 - Jekel, Martin T1 - Settling Velocities of Tire and Road Wear Particles: Analyzing Finely Graded Density Fractions of Samples from a Road Simulator and a Highway Tunnel N2 - The terminal settling velocity is considered the most critical parameter determining the transport of tire and road wear particles (TRWP) in aquatic environments. Nonetheless, no respective empirical data has been reported so far. In this study, particle samples from a road simulator and a highway tunnel were investigated with a validated imaging method. Different density and size fractions of both samples were measured separately, acquiring sizes and settling velocities of more than 30,000 individual particles. In addition, tire marker polymers were analyzed for each fraction via thermal extraction desorption-gas chromatography/mass spectrometry. Finally, the acquired particle data was combined according to the fractions’ estimated tire contents in order to deduce detailed probability distributions of particle size and settling velocity for the actual TRWP from both samples. Weighted by TRWP-incorporated tire mass, median diameters of 54 and 44 μm as well as median settling velocities of 0.65 and 0.22 mm/s were found for TRWP from the road simulator and highway tunnel, respectively. This study thus provides the first ever empirical data on TRWP settling velocities in water, which can be highly valuable input for modeling the environmental transport of TRWP and for dimensioning TRWP retention systems. KW - Microplastics KW - TED-GC/MS KW - Sinking velocities KW - Transport PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635449 DO - https://doi.org/10.1021/acs.est.5c04165 SN - 0013-936X VL - 59 IS - 26 SP - 13434 EP - 13446 PB - American Chemical Society (ACS) AN - OPUS4-63544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rossi, A T1 - Lactose Tablets as Suitable Microplastics Reference Material to Support Validation Studies and Quality Control N2 - One of the main challenges in validating microplastics detection methods is the lack of suitable reference materials that accurately reflect the properties of interest. To bridge this gap, the EU-funded PlasticTrace project has developed water-soluble tablets containing precisely defined amounts of polyethylene terephthalate (PET) particles. Each tablet includes a specific mass (0.2, 18.5, or 400 µg) and particle count (151 or 1764, measured via Raman spectroscopy). Production follows a rigorous solid-phase dilution process, ensuring high reproducibility and quality control. The PET particles used in these tablets have an average size of approximately 40 µm, with a range between 10 and 200 µm, and an irregular, stone-like shape. All measurements align with ISO/TC 147/SC 2 standardization efforts and adhere to ISO/DIS 16094-2 and ISO/DIS 16094-3. To assess tablet homogeneity, the most widely accepted microplastics detection techniques, i.e. µ-FTIR, µ-Raman, Py-GC/MS, and TED-GC/MS, were applied. Different batches were produced, each containing varying particle numbers and masses, reaching the detection limits of the methods used. The results demonstrated excellent consistency between tablets, successfully passing homogeneity tests. Furthermore, no significant changes were observed in the tablets' composition or stability after six months of storage. This innovative reference material represents an important advancement in microplastics analysis, supporting laboratories in meeting EU Commission requirements for the monitoring of microplastics in drinking water and wastewater with greater accuracy and reliability. The production process can be transferred for other plastic particles is this size range. T2 - BERM 16 CY - Halifax, Canada DA - 01.06.2025 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Raman microscopy PY - 2025 AN - OPUS4-63403 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Visileanu, Emilia A1 - Altmann, Korinna A1 - Stepa, Raluca A1 - Haiducu, Maria A1 - Miclea, Paul Tiberiu A1 - Vladu, Alina A1 - Dondea, Felicia A1 - Grosu, Marian Catalin A1 - Scarlat, Razvan T1 - Comparative Analysis of Airborne Particle Concentrations in Textile Industry Environments Throughout the Workday N2 - This paper addresses the growing concern surrounding microplastic pollution, particularly within the textile industry, and the associated potential health risks linked to the inhalation and ingestion of microplastic particles. Microplastics, defined as plastic particles smaller than five millimeters, are increasingly found not only in aquatic environments, but also in soils, air, and food. Although research on the health impacts of microplastics is still emerging, early studies indicate that these particles could contribute to health issues, including oxidative stress, inflammation, and cardiovascular diseases. Notably, individuals with higher concentrations of plastics in arterial plaques are more susceptible to heart attacks and strokes. In the textile industry, synthetic fibers such as polyester, nylon, and acrylic release microplastics into the air during production. The paper discusses a study conducted in a textile company that processes polyester yarns, where airborne microplastic concentrations were measured at various locations throughout the day. Particle sizes ranging from 0.3 nm to 10 nm were analyzed, revealing the presence of polyester polymers in the particulate matter. These findings underscore the widespread nature of microplastic pollution, particularly in industrial settings, and raise concerns about the health risks associated with prolonged exposure to airborne microplastics. While further research is necessary to fully understand the extent of these health impacts, preliminary data suggest a troubling link between microplastic inhalation and cardiovascular conditions. KW - Microplastics KW - Textiles KW - Airborne particles PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635269 DO - https://doi.org/10.3390/microplastics4020034 SN - 2673-8929 VL - 4 IS - 2 SP - 1 EP - 17 PB - MDPI AG AN - OPUS4-63526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P-T T1 - Evaluation of Toxicological Characteristics of Airborne Nano/Microplastic Particles From the Industrial Environment N2 - Micro and nano plastic (MNPs) particles and fibres represent a global scale contamination source with hazard potential. They can be identified all around our environment, even in air, soil and water. One of the major global MNPs polluters is the textile industry, which generates plastic particles (nylon, polyester, polyurethane, polyolefin, acrylic etc.) during the manufacturing processes. The study analyses the level of particle concentration outside a company that processes textile yarns, but also from the proximity of workplaces using an online air samplers with cascade and mono filter holders for silicon (Si) and quartz filters, respectively. A laser detector was used for real- time counting of particles of six size classes (PM0.3-PM10). Silicon (Si) filters with a diameter of 9 mm and pore sizes of 10 µm and 1 µm and quartz filters with a diameter of 25 mm and a pore size of 1.2 µm were used for particle sampling. A special holder was designed and made for selective sampling (PM10 and PM1.0) on Si filters. Quartz filters were pre-calcined (8000C) before collection. Sampling parameters: airflow (GilAir Plus pump) -2 l/m3, collection time -3 hours; starting time 7.00 am (T1)/2.00 pm (T2), intermittent natural ventilation, average temperature and humidity: 23.3 0C, RH: 52.5%. The weight of particles collected (µg) on the quart filters was 4.9E-05 (T1) and 5.1E-05 (T2) and on the Si filters 3,2 E-05(T1) and 5E-06(T2). The total number of the outside particles (PM0,3-PM10) was situated between 3584,58 (T1)-15165,05(T2) and inside 9901(T1) and 12921,61(T2). The highest number of PM 10 particles inside was 72/m3 and of PM0.3 particles 71979/m3. The samples were characterized using electron microscopy and µRaman spectroscopy. All samples showed a high concentration of particles on the filter. Samples show only particles with irregular shapes. The equivalent particle diameter was for PM10: 1-5 µm and PM1<1 µm. The total Ion Chromatogram shows the presence of PET-type polymer and the TED GS-MS analysis shows that the weight of the collected particles is PET. After extracting the particles from the quartz filters, they were tested for evaluation of the cytotoxic potential of preparations on human monocyte-macrophage cell cultures and peripheral lymphocytes. In the first case, the level of cytotoxicity was at the border between non-cytotoxic and cytotoxic and in the second test the result was moderate cytotoxic. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - TED-GC/MS KW - Nanoplastics KW - Raman microscopy PY - 2025 AN - OPUS4-63378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, P.-T. T1 - Novel laser pre-structured silicon filters for microplastics analysis N2 - This research presents a novel laser-assisted approach to silicon filter fabrication, offering an effective alternative to traditional photolithographic processes. By integrating selective femtosecond laser irradiation with photoelectrochemical etching, we achieved precisely controlled pore geometries, overcoming common challenges in filter production for microplastic and nanoscale filtration suitable for microplastic number and mass analysis. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics KW - Raman microspectroscopy PY - 2025 AN - OPUS4-63384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hülagü, Deniz A1 - Ermilova, Elena A1 - Weise, Matthias A1 - de Préville, Sophie A1 - Hoffmann, Johannes A1 - Morán-Meza, José A1 - Piquemal, Francois A1 - Hertwig, Andreas T1 - Characterization of electrical properties in microstructured ITO layers using spectroscopic ellipsometry N2 - Thin indium tin oxide (ITO) layers are essential in optoelectronics due to their good electrical conductivity, optical transparency in the visible and near infrared regions, substrate adherence and chemical stability. They are widely used in photovoltaic cells, displays, and organic LEDs, and as low emissivity coatings in smart windows and energy-efficient buildings. For nanophotonic devices, understanding the interplay of ITO’s optical and electrical properties is crucial. Electrical resistivity can be tuned by modifying deposition conditions and layer thickness. However, measuring these properties, especially on microstructured surfaces, remains challenging due to the issues like homogeneity and instability during etching. Spectroscopic ellipsometry (SE), a non-destructive and phase-sensitive optical technique, offers precise measurement of thin film thickness and dielectric properties. In this study, we investigated the layer thickness, optical constants, and sheet resistance of unstructured and microstructured ITO thin layers using SE. Unstructured layers were deposited via DC-magnetron sputtering on silicon (Si) substrates in argon (Ar) atmospheres with varying oxygen (O2) flows. This multi-technique approach enhances the understanding of ITO layer structuring and provides robust methodologies for correlating optical and electrical properties, advancing metrology for nanotechnology applications and material science. It also opens the pathway to new reference samples and calibration methods for electrical properties involving device-like structured samples. T2 - ICSE10 - 10th International Conference on Spectroscopic Ellipsometry CY - Boulder, CO, USA DA - 08.06.2025 KW - Ellipsometry KW - Indium tin oxide (ITO) KW - Scanning microwave microscopy (SMM) KW - Sheet resistance calibration standards KW - ITO wet etching PY - 2025 AN - OPUS4-63631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fink, Friedrich A1 - Stawski, Tomasz M. A1 - Emmerling, Franziska A1 - Falkenhagen, Jana T1 - A novel machine-learning approach to unlock technical lignin classification by NIR spectroscopy - bench to handheld N2 - In this research, the utilization of near-infrared (NIR) spectroscopy in conjunction with advanced machine learning methods is investigated for categorizing technical lignins obtained from different biomass sources and industrial procedures. Technical lignins, such as kraft, organosolv and lignosulfonates, have different chemical compositions, which continue to make uniform characterization and application in sustainable sectors extremely difficult. Fast, universally accessible analytics combined with data analysis is still an open question. For the first time three distinct NIR spectrometers—a high-performance benchtop system, a mid-priced compact device, and an economical handheld unit—were utilized to record NIR spectra of 31 unique lignin samples. The spectra underwent pre-processing through standard normal variate (SNV) transformation and Savitzky-Golay derivatives to amplify spectral features and decrease noise. Principal component analysis (PCA) was employed to reduce data complexity and extract crucial characteristics for classification purposes. Subsequently, four machine learning algorithms—Support Vector Machines (SVM), Gaussian Naive Bayes (GNB), Gaussian Process Classification (GPC), and Decision Tree Classification (DTC)—were implemented for the classification of the lignin samples. The DTC model exhibited the highest accuracy among them across different spectrometers. Although the benchtop spectrometer produced the most precise outcomes, the compact NeoSpectra system also displayed potential as a cost-efficient option. Nonetheless, the restricted spectral coverage of the handheld NIRONE spectrometer resulted in reduced classification accuracy. Our discoveries highlight the capability of NIR spectroscopy, combined with robust data analysis techniques, for the swift and non-destructive classification of technical lignins, facilitating their improved utilization in sustainable fields. KW - Technical lignins KW - NIR spectroscopy KW - Classification KW - Machine-learning KW - PCA PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-634518 DO - https://doi.org/10.1016/j.chemolab.2025.105467 SN - 0169-7439 VL - 264 SP - 1 EP - 10 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-63451 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Goedecke, Caroline A1 - Bannick, C.-G. A1 - Abusafia, A. A1 - Scheid, C. A1 - Steinmetz, H. A1 - Paul, Andrea A1 - Beleites, C. A1 - Braun, U. T1 - Identification of microplastic pathways within a typical European urban wastewater system N2 - In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other. KW - Microplastics KW - Microplastic analysis KW - TED-GC/MS KW - Microplastic pathways KW - Mass contents PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568289 DO - https://doi.org/doi.org/10.1002/appl.202200078 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, U. T1 - Detection of plastics in soil N2 - Soil acts as a final sink for pollutants. Microplastics from different sources such as plastic mulching, littering, compost, sewage sludge, sedimentary deposition, and tyre abrasion are expected to be found in soil. However, representative and comprehensive information is missing on the sources, transport, and fate. Therefore, a reliable analysis method for microplastics in soils needs to be developed. The presented work describes the development of a procedure for microplastics analysis in soils. A representative sampling based on the on-site conditions and a sample preparation method was established and comprised of a drying step, the separation of microplastic particles > 1 mm, and a density separation for particles < 1 mm. The detection of the large microplastic particles (> 1 mm) was conducted with Attenuated Total Reflection - Fourier Transform infrared Spectroscopy (ATR-FTIR) , while Thermal Extraction Desorption - Gas Chromatography / Mass Spectrometry (TED-GC/MS) was applied for particles < 1 mm, gaining information on the type of polymer and mass fraction. Based on the established method, 14 environmental soil samples ? with different exposure of microplastics from agriculture, industrial sites, roads, and floods were investigated. Due to the arbitrary microplastic particle distribution among the samples for large microplastics, it was reasoned that the found particles were unrepresentative. In contrast, microplastic particles < 1 mm were discovered in a high mass in soil samples exposed to plastic mulching or fertilization with sewage sludge or compost (0 – 115 mg/kg). On average, microplastic contents detected in soil samples taken from a construction site and an inner-city lake were higher (13 – 238 mg/kg). As expected, microplastic content in soil sampled in proximity to roads was more pronounced in the upper soil layers. In contrast, very remote sampling sites, expectably uncontaminated, did not lead to the detection of microplastic regarding to thermoanalytical detection method. In a proof of concept experiment several in vivo and in vitro ecotoxicological tests were applied to evaluate the effect of microplastics (tyre abrasion, polystyrene containing hexabromocyclododecane) in natural soils. In summary, while no effects of the examined probes could be detected on higher levels of biological organization after exposures to earthworm E. andrei, significant changes in several oxidative stress related biomarkers were observed. T2 - SETAC Europe 2022 CY - Kopenhagen, Denmark DA - 15.05.2022 KW - Microplastic KW - TED-GC/MS KW - Soil PY - 2022 AN - OPUS4-55872 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Plastik in Böden: Mikroplastik-Ergebnisse N2 - In diesem Vortrag geht um die Vorstellung der Ergebnisse des UBA Projektes Plastik in Böden. Es werden Mikroplastik-Gehalte in verschiedenen Böden präsentiert. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - Mikroplastik Böden KW - Mikroplastik-Analytik PY - 2022 AN - OPUS4-54648 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik an der BAM: TED-GC/MS und Referenzmaterialien N2 - Thema ist die Funktionsweise der TED-GC/MS als Methode für die Mikroplastik-Detektion sowie die Herstellung dazugehöriger Referenzmaterialien an der BAM T2 - 25. Kolloquium Massenspektrometrie von Polymeren CY - Online meeting DA - 17.06.2021 KW - Mikroplastik KW - TED-GC/MS KW - Referenzmaterial PY - 2021 AN - OPUS4-52835 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Linberg, Kevin T1 - Controlled Polymorphism by Elevated Temperature Ball Milling N2 - Mechanochemistry provides polymorphs that are difficult to obtain by conventional solution-based methods. Based on the nicotinamide and pimelic acid cocrystal, we demonstrated that the ball size, frequency, and temperature are essential parameters. Our results indicate that fine-tuning the energy input during a mechanochemical reaction can provide control over polymorphism. T2 - Bessy User Meeting 2023 CY - Berlin, Germany DA - 22.06.2023 KW - Mechanochemistry KW - Temperature KW - Cocrystal KW - Energy input KW - Polymorph PY - 2023 AN - OPUS4-57985 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Reference material candidates for microplastic analysis N2 - Every day, there are new headlines in the media about microplastics (1-1000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) findings all over the planet with high variations in particle number and mass. The challenges in analytics are very complex, e.g. representative sampling, non-destructive sample preparation with concentrated particles and homogeneous distribution and true detection. All together lead to lacks in harmonization and results, which are hardly comparable. On the other hand, monitoring of microplastics is mandatory in the future strictly regulated by the EU commission in the Drinking water and Wastewater Framework Directive. One step to accurate and precise results will be the development of suitable reference materials mimicking particles in the environment. BAM developed test materials, which are produced by mixing a small portion of microplastic particles with a water-soluble matrix. After solid phase dilution and homogenisation small portions are pressed into tablets and bottled in glass vials (Figure 1). These tablets are well characterized with particle size distribution and SEM images. Additionally, they are tested as reference material candidate according to homogeneity and stability for particle number with µ-IR and µ-Raman as well as on particle mass with Py-GC/MS and TED-GC/MS after ISO Guide 35. Results are promising. The material passed the homogeneity control. No changes are observed within 6 months of storage. The same tested reference material is finally used in sample preparation experiments, where environmental suspended particular matter from surface water or baby milk powders are spiked with the tablets. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polymer 3R KW - Tablets PY - 2024 AN - OPUS4-61017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, Claudia T1 - Rapid sample preparation to detect microplastics in baby milk powder N2 - Microplastics, ubiquitous as it is, could be released into food during production chain, through packaging and by consumer´s use. To determinate human exposure to microplastics is crucial to monitor microplastics in food matrices. The current absence of standard sample preparation procedures to identify and quantify different microplastics according to number and mass have generate time-consuming protocols and lack of comparability among different analytical methods, laboratories and time scales. Monitoring microplastics in complex matrices as food, and in particular in baby milk powder, requires an accurate approach that need to be validate, to ensure the comparability of results. Bottled drinking water or surface waters, for example, can be measured with mass-based methods (TED-GC/MS or Py-GC/MS) directly after filtration. Baby milk powder, instead is more challenging, due to the proteins and fatty acid that clog the filters and contaminate the measuring devices with heavy carry over. In this study, we characterize the baby milk powder by thermogravimetric analysis (TGA) and we tested different treatments for matrix reduction: water, H2O2, citric acids. In particular, the use of citric acid was tested for protein reduction before filtration. Our hypothesis was that citric acid will induce the precipitation of proteins and amino acids, leading to a strong matrix reduction. In fact, this sample pre treatment, allowed us to use a higher intake, necessary for representative quantification. Finally, the milk powder was spiked with reference material tablets containing polyethylene terephthalate (PET). The PET was not degraded by the citric acid and high recovery rate was achieved by TED-GC/MS and Py-GC/MS methods. Considering the simplicity and accessibility of this sample preparation and its robust results, this procedure could be easily proposed as a simple sample preparation approach to monitor microplastics by mass-based methods. T2 - MICRO 2024 CY - Arrecife, Spain DA - 23.09.2024 KW - Microplastics KW - Milk KW - Polymer 3R KW - TED-GC/MS PY - 2024 AN - OPUS4-61273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Plastik in Böden: Mikroplastik-Analytik N2 - Im Vortrag wir eine Methode zur Analyse von Mikroplastik in Böden dargestellt. Es geht dabei um die Probenvorbereitung und Detektion. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik KW - Methodenentwicklung Böden PY - 2022 AN - OPUS4-54646 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -