TY - GEN A1 - Bäßler, Ralph T1 - Impedance spectroscopy: Theory, experiment and applications (Book review) N2 - This textbook fulfills its dedication of being the “essential reference for the field, featuring protocols, analysis,fundamentals and the latest advances” of impedance spectroscopy to its readers. It really provides an insight in all facets of this powerful technique. It should not be missed in the bookshelf of electrochemists and all other interested researchers and engineers who want to be on the current state of this technique. KW - Impedance spectroscopy KW - Surface PY - 2019 DO - https://doi.org/10.1002/maco.201970064 SN - 1521-4176 SN - 0947-5117 VL - 70 IS - 6 SP - 1133 PB - WILEY ‐ VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-48210 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hauke, Max T1 - Entwicklung eines Versuchsstandes zur Dickenbestimmung von Werkstoffen mithilfe von frequenzmoduliertem Ultraschall N2 - Die vorliegende Arbeit beschäftigt sich mit der Entwicklung eines Versuchsstandes zur Di-ckenbestimmung von Werkstoffen mithilfe von frequenzmoduliertem luftgekoppelten Ultra-schall. Zur Erzeugung des frequenzmoduliertem Signals wird ein fluidischer Oszillator ver-wendet. Die Schwingungsfrequenz des Oszillators ist von der Größe, der Geometrie und den Druckverhältnissen im Oszillator abhängig, welche durch ein Druckventil veränderbar sind. Zur Datenfassung dienen zwei Laservibrometer. Weiterhin soll die schlussendliche Dicken-bestimmung mithilfe eines Kreuzkorrelationsverfahrens erreicht werden. Während der Ent-wicklung wurden Messungen im Medium Luft, als auch mit Polyamid-Probekörpern durchge-führt. Für die Luftmessungen wurde das Ultraschallsignal an zwei Messpunkten erfasst und der Abstand zwischen diesen Messpunkten daraufhin versucht zu ermitteln. Diese Abstand-messungen wurden mit unterschiedlichen Abständen von 6 bis 15 Zentimeter durchgeführt, wobei der Abstand anhand der Daten mit einer Abweichung von unter einem Zentimeter er-folgreich bestimmt werden konnte. Die Messungen am Probekörper waren weniger Erfolg-reich, da keine reproduzierbare Dickenbestimmung erreicht werden konnte. Trotzdem kann die Entwicklung aufgrund der erfolgreichen Abstandmessung in der Luft sowie den neuen Erkenntnissen aus den Messungen am Probekörper als Erfolg betrachtet werden. KW - Berührungsloser Ultraschall KW - Bauwesen KW - Frequenzmodulation KW - Fluidische Anregung PY - 2019 SP - 1 EP - 74 CY - Berlin AN - OPUS4-50219 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schönhals, Andreas ED - Zorn, R. T1 - Quasi-elastic scattering of high free volume polymers by neutron time-of-flight spectroscopy N2 - Neutron backscattering experiments have been carried out on a polymer of intrinsic microporosity KW - Polymers of Intrinsic Microporosity PY - 2019 SP - 1 EP - 2 CY - Garching AN - OPUS4-49852 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Alhadad, Mohamad Saddik T1 - Entwicklung und Validierung eines luftgekoppelen Impakt-Echo-Messverfahrens mittels fluidischer Anregung N2 - Die steigende Nachfrage von zerstörungsfreien Prüfverfahren, welche die Zeitinvestition verbessern und eine kontinuierliche Messung ermöglichen, erfordert die Entwicklung des luftgekoppltes Impakt-Echo-Messverfahrens. Diese Entwicklung kann durch die fluidische Anregung ermöglicht werden. Das Ziel dieser vorliegenden Arbeit war der Aufbau einer Messapparatur, die auf Schnelligkeit setzt und kontinuierlich misst. Nach der Durchführung der fluidischen Anregung wurden mit Hilfe eines Laservibrometers die Daten aufgenommen. Zur Analysierung der auf diese Weise erhobenen Messwerte wurden sie mittels der Fast-Fourier-Transformation in den Frequenzbereich transformiert. Für den Zweck der Validierung wurden Zylinder-Probekörper und Platten-Probekörper wurden verwendet. Die Messungen an den Zylinder-Probekörpern lieferten erfolgreiche Ergebnisse, während die Messungen an den Platten-Probekörpern weitere Untersuchung und Entwicklung benötigten werden. KW - Bauwesen KW - Delamination KW - Kontaktloses Impakt-Echo KW - Dickenbestimmung PY - 2019 SP - 1 EP - 87 CY - Berlin AN - OPUS4-50320 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Luco Colilles, Arnau T1 - Evaluation of two compact near-infrared spectrometers for the detection of microplastics in soil samples N2 - In the last years, the Process Analytical Technology (PAT) research field has become of great importance due to its connection with the industrial world. This industry related research, along with the evolutionary progress that technology has seen lately, has allowed that key analytical techniques in an industrial environment have undergone a radical development. One of these techniques has been the near-infrared spectroscopy (NIRS). This technique, currently common in "online" industrial analysis, has seen a remarkable revolution, especially since the introduction of the microelectromechanical systems technology (MEMS) in the spectroscopy field. Nowadays it is possible to find compact spectrometers no bigger than a wristwatch in the market. Although there is an unavoidable question: can these compact spectrometers actually compete against the traditional spectrometers? In this project different calibration parameters of two compact NIR spectrometers ("Spectral Engines Oy NIR-One Sensor NM2.0", with 1550 to 1950 nm range; and "NeoSpectra Si-ware", with 1300 to 2550 nm range) were evaluated, and the obtained results were compared with a reference spectrometer ("Bruker Optik GmbH Matrix-F", with 15000 to 4000 cm–1 range). In order to obtain the different calibration parameters, a sequence of quality performance tests were conducted. The results obtained after the different experiments carried out with both compact spectrometers prove that their performance is more than acceptable for routine analysis. Afterward, model samples of different microplastics in soil at different known concentration were analyzed with all three spectrometers. Chemometric models capable to identify and classify microplastics in soil were established. For this analysis five of the most used plastics worldwide were used: polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), and polyvinyl chloride (PVC). After the Principal component analysis (PCA), it can be seen that only the NIR-One NM2.0 is capable to differentiate all types of microplastics in soil at concentrations of 1–2 %, while the NeoSpectra Si-ware is unable to identify the PET sample. KW - Near-infrared KW - Microplastics KW - Compact spectrometers PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-511626 UR - http://hdl.handle.net/2445/138198 SP - 1 EP - 29 PB - Universitat de Barcelona CY - Barcelona AN - OPUS4-51162 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Tscheuschner, Georg T1 - Entwicklung einer Methode zur schnellen Identifikation von Antikörpern mittels MALDI-TOF-MS N2 - Im Vergleich zu anderen Proteinen ist die Identifizierung von Antikörpern anhand ihrer Sequenz zum Beispiel mittels "peptide mass fingerprinting" schwierig. Da die Sequenzinformation eines Antikörpers aufgrund der hypersomatischen Mutation während der Affinitätsreifung nicht im Genom eines Organismus gespeichert ist, kann die Aminosäuresequenz nicht auf einfachem Weg der DNA-Sequenzierung gewonnen werden. Das ist nur in seltenen Fällen möglich, wenn dem Endanwender der Zellklon der Antikörper-produzierenden Zelle zugänglich ist. Eine Sequenzierung auf Protein-Ebene ist sehr aufwändig und teuer und wird daher fast nie für die Charakterisierung von analytischen Antikörpern verwendet. Der Mangel an Validierung dieser analytischen Antikörper, die bei Experimenten verwendeten werden, löst aber eine Reihe Probleme aus, die die Wiederholbarkeit dieser Experimente schwierig und in einigen Fällen unmöglich macht. Das sorgt jährlich für verschwendete Forschungsgelder in Milliardenhöhe und hindert den wissenschaftlichen Fortschritt. Ziel der vorliegenden Arbeit war die Entwicklung einer einfachen und schnellen Methode, die es trotzdem ermöglicht, die Identifikation von Antikörpern sicherzustellen. Dazu wurde eine Methode basierend auf dem "peptide mass fingerprinting" gewählt. Das Problem der unbekannten Aminosäuresequenz der Antikörper wurde gelöst, indem lediglich die Peptidmuster der entstehenden Fingerprint-Spektren zur Identifikation herangezogen wurden. MALDI wurde dabei als Ionisationsmethode für die Massenspektrometrie gewählt, da die resultierenden Spektren im Gegensatz zu ESI-MS einfach auszuwerten sind. Auch kann auf eine vorige Trennung der Peptide mittels LC verzichtet werden, was zusätzlich Analysenzeit spart. Für die Proteinspaltung wurde eine simple saure Hydrolyse mittels Ameisensäure gewählt. Im Vergleich zum herkömmlichen Trypsin-Verdau konnten auf zeitraubende Arbeitsschritte wie Denaturierung, Reduktion und Alkylierung der Antikörper verzichtet werden. Die Hydrolyse mittels Ameisensäure wurde bisher nur auf kleine und mittelgroße Proteine angewendet, sodass im ersten Teil dieser Arbeit mehrere Schritte optimiert wurden bevor zufriedenstellende Fingerprint-Spektren von Antikörpern erhalten wurden. KW - Peptide KW - Fingerprint KW - Peptide mass fingerprinting KW - Massenspektrometrie KW - Saure Hydrolyse KW - Festphasenextraktion KW - Protein G KW - Ameisensäure KW - ABID KW - Korrelationsmatrix PY - 2019 SP - 1 EP - 116 PB - Humboldt-Universität zu Berlin CY - Berlin AN - OPUS4-54626 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bäßler, Ralph T1 - Review: Physical Electrochemistry – Fundamentals, Techniques, and Applications N2 - The second edition of this textbook on physical electrochemistry, written by two experienced teachers of physical chemistry, corrosion engineering and materials science and engineering, covers the current knowledge which should be transferred to students of these fields. In 20 chapters the fundamentals of electrochemistry, the most important electrochemical measurement techniques and applications of electrochemistry are covered. It can be concluded that this study fulfills its intension of “serving as a key textbook in undergraduate courses” dealing with electrochemistry and being “a reference source for graduated students, researchers and engineers” interested in this field. Teachers will find sufficient content for preparing lectures on this topic. Even self‐learning is well supported by the clear structure, presented content and provided sources for further reading. KW - Corrosion KW - Electrochemistry PY - 2019 DO - https://doi.org/10.1002/maco.201970124 SN - 1521-4176 SN - 0947-5117 VL - 70 IS - 12 SP - 2345 EP - 2346 PB - WILEY‐VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-50017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pötzsch, Sina T1 - Practical Testing and Evaluation of Plastics (Book review) N2 - One can conclude, this first edition of “Practical Testing and Evaluation of Plastics” provides a comprehensive and compact reference. It can be recommended as clear overview as well as introducing manual for everyone working with characterization and testing of plastics. KW - Plastic KW - Testing PY - 2019 DO - https://doi.org/10.1002maco.201970054 SN - 0947-5117 SN - 1521-4176 VL - 70 IS - 05 SP - 931 EP - 932 PB - WILEY-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-48013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -