TY - CONF A1 - Winckelmann, Alexander T1 - Why do I have to charge my phone twice a day? N2 - Aging Mechanisms of Lithium Batteries: How can we make batteries more durable and more sustainable in the future? Lithium batteries are particularly susceptible to ageing processes. During each charging and discharging process in an electric battery, lithium ions are deposited in the electrodes of the cell like in the pores of a sponge. Over time, however, fractures and cracks occur in the filigree structures. The result: more and more lithium ions no longer fit into the hollow spaces of the „sponge“, instead they accumulate in heaps around the electrodes and hinder the movement of other ions. The performance of the battery decreases. We present our new project, in which we are developing a fast and cost-effective method with which companies that produce lithium batteries can already assess the ageing behaviour of their batteries in the laboratory. T2 - Berlin Science Week 2022 CY - Online meeting DA - 10.11.2022 KW - Lithium Ion Batteries KW - Aging Mechanisms PY - 2022 UR - https://berlinscienceweek.com/de/event/why-do-i-have-to-charge-my-phone-twice-a-day/ UR - https://www.youtube.com/watch?v=bF7bQTY49rQ AN - OPUS4-56245 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tavernaro, Isabella T1 - Where Do We Stand – Quantifying Amino Groups on Silica (Nano)Particles N2 - Industry and regulators are increasingly requesting validated and standardized measurement protocols to support the manufacturing, quality control, and safe use of engineered nanomaterials. Addressing a remaining gap in method development and standardization for nanomaterial characterization, we investigated in a bilateral comparison various methods commonly used for surface functional group quantification, like quantitative nuclear magnetic resonance (qNMR) spectroscopy, x-ray photoelectron spectroscopy (XPS), and optical assays. These results demonstrate not only an influence of the size and synthesis methods on the number of surface functional groups for differently sized commercial and in-house synthesized silica nanoparticles but also on their functionality. T2 - Kickoff-Meeting SMURFnano CY - Berlin, Germany DA - 09.07.2024 KW - Nano KW - Particles KW - Silica KW - Synthesis KW - Quantification KW - Functional groups KW - Quality assurance KW - Reference material KW - Interlaboratory comparison KW - Method KW - Uncertainty KW - Sensor KW - Surface analysis PY - 2024 AN - OPUS4-62164 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lisec, Jan T1 - When drowning in data - start swimming N2 - A presentation on the subject of Automatic Data Processing Skills in Chemistry to Enhance Scientific Research. T2 - 7th PhD Seminar of the German Working Group for Analytical Spectroscopy (DAAS) in the GDCh Division of Analytical Chemistry CY - Berlin, Germany DA - 15.11.2023 KW - Data KW - Automation KW - Programming PY - 2023 AN - OPUS4-58902 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Abad Andrade, Carlos Enrique T1 - What does GD-OES reveal about the aging and manufacturing processes of lithium-ion batteries? N2 - Glow-Discharge Optical Emission Spectroscopy (GD-OES), a powerful analytical technique, sheds light on the two critical aspects of lithium-ion batteries (LIBs): manufacturing and aging 1, 2. We optimized cell production in manufacturing by adjusting parameters, including cathode doping, electrolyte concentration, and pressing force. GD-OES provided in-depth elemental composition and homogeneity analysis, which is crucial for identifying optimal manufacturing conditions. These findings were validated by electrochemical impedance spectroscopy, confirming the quality of the manufactured batteries. Shifting the focus to aging, we use GD-OES for fluorine depth profiling, a key element in understanding polymer and electrolyte degradation. However, fluorine presents analytical challenges. We addressed this by substituting argon with a neon:argon mixture, which significantly enhanced fluorine detection sensitivity. This advancement not only improves accuracy but also holds the potential to guide sustainable and cost-efficient manufacturing strategies. Through its versatility, GD-OES has proven to be a powerful tool for not only optimizing LIB manufacturing processes but also gaining deeper insights into their aging mechanisms. This research extends beyond academic interest, offering tangible benefits for the industry by translating into improved battery quality, extended lifespan, and overall performance. T2 - The 6th International Glow Discharge Spectroscopy Symposium CY - Liverpool, United Kingdom DA - 21.04.2024 KW - GD-OES KW - Depth profiles KW - Lithium KW - Battery KW - Fluorine KW - Aging KW - Manufacturing KW - Glow-discharge PY - 2024 AN - OPUS4-59945 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Meermann, Björn T1 - Von Elementspezies, Isotope und Zellen oder: wie kommt man eigentlich von Westfalen nach Berlin N2 - Im Rahmen des Vortrages werden die Möglichkeiten der Elementanalytik an Applikationsbeispielen aus Umwelt und life-sciences aufgezeigt. Hierbei kommen ICP-MS Kopplungstechniken, stabile Isotope und Einzellen- und Partikelanalytik (sc-/sp-ICP-ToF-MS) zum Einsatz. T2 - DAAS PhD Seminar CY - Online meeting DA - 20.09.2021 KW - Elementspezies & Isotope KW - ICP-MS & HR-CS-GFMAS KW - Kopplungstechniken PY - 2021 AN - OPUS4-53378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Temgoua, Ranil C. T. T1 - Voir les choses sous un autre angle : Comment l’électrochimie analytique aide à révolutionner l'analyse chimique N2 - As part of the "Journées de Chimie Analytique, JCA Dschang 2024", this plenary scientific conference will explore how analytical electrochemistry is fundamentally changing modern chemical analysis methods. We will highlight key innovations such as wearable/handheld sensors, lab-on-a-chip, lab-on-paper, lab-on-a-glove, integrated detection systems with artificial intelligence, and point-of-care (POC) technologies. We will also address the couplings between analytical electrochemistry and various analytical techniques such as mass spectrometry (EC-MS), chromatography (EC-LC), spectroscopy [EC-spectroscopy (UV-VIS, Raman, IR, NMR)], microscopy [EC-microscopy (EM, AFM)], and capillary electrophoresis (EC-CE). These advances enable faster, more accurate, and more accessible analyses, opening new perspectives for research and practical applications in environmental science, food and agriculture, public health, and advanced materials. T2 - Journées de Chimie Analytique 12th Edition CY - Dschang, Cameroon DA - 28.08.2024 KW - Organic Trace Analysis KW - Electrochemistry KW - Mass Spectrometry PY - 2024 AN - OPUS4-61064 LA - fra AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klaus, Christian T1 - Verwaltungsschale Industrie 4.0 N2 - Die Veranstaltung richtet sich an alle Mitarbeiter der BAM. Ziel ist es, allen eine Idee zu vermitteln, was die Verwaltungsschale ist und wie sie angewendet werden kann. Die Zuhörer sollen hinterher eine Idee haben, ob bei ihrer eigenen Arbeit potenzielle Anknüpfungspunkte bestehen. Inhalt: • Beispiel aus QI Digital als Motivation (Problemstellung) • Beschreibung der VWS als Lösungsansatz für einheitliche Datenstrukturierung (mit verschiedenen Nutzern) • Fokus liegt nicht auf Neuentwicklung, sondern auf der Nutzung vorgeschlagener Werkzeuge und Standards der Industrie 4.0 • Struktur der Verwaltungsschale T2 - BAM Kolloquium CY - Berlin, Germany DA - 29.05.2024 KW - Verwaltungsschale KW - Digitaler Zwilling KW - Interoperabilität PY - 2024 AN - OPUS4-63498 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Abad Andrade, Carlos Enrique T1 - Versatility of nitrogen microwave-induced plasma mass spectrometry in elemental and isotopic analysis N2 - The introduction of Nitrogen-based Microwave Inductively Coupled Atmospheric-Pressure Plasma Mass Spectrometry (MICAP-MS) addresses the necessity for a plasma source that matches the capabilities of traditional argon-based Inductively Coupled Plasma Mass Spectrometry (ICP-MS) while exploiting the availability and cost-effectiveness of nitrogen gas. MICAP-MS uses nitrogen plasma, offering significant advantages such as reduced operational costs and eliminating specific isobaric interferences common in argon plasma systems [1]. This presentation explores the principles of MICAP-MS, highlighting its similarities to conventional ICP-MS in terms of analytical performance while emphasizing unique benefits like eliminating interferences from argon-based polyatomic species. MICAP-MS exhibits robust performance using nitrogen gas of varying purities—including ultra-high purity and industrial-grade nitrogen—without compromising analytical results [2]. We have applied MICAP-MS for multielement analysis in soil samples, serving as a proof of concept for environmental monitoring applications. The technique achieved figures of merit comparable to traditional ICP-MS, even when analyzing real-world samples with complex matrices [2]. MICAP-MS demonstrated high tolerance to high-concentration matrices, maintaining accuracy and precision without extensive sample preparation or matrix separation [3]. In clinical diagnostics, MICAP-MS was employed for the precise and traceable quantification of calcium, iron, and selenium in human serum using isotope dilution analysis [4]. These elements often face interferences in argon-based ICP-MS due to argon-associated isobaric interferences (40Ca+, 56Fe+, and 80Se+); however, MICAP-MS effectively overcomes these challenges, providing traceable and accurate determinations. The stability of the microwave plasma in MICAP-MS facilitates precise isotopic analysis. This capability investigated age-induced lithium isotope fractionation in lithium-ion batteries, offering critical insights into battery aging mechanisms and performance degradation [5]. MICAP-MS is a versatile analytical tool that combines the operational benefits of nitrogen plasma with the strengths of traditional ICP-MS. Its ability to handle complex matrices, reduce interferences, and perform precise elemental and isotopic analyses across various applications makes it a valuable instrument. T2 - European Winter Conference on Plasma Spectrochemistry CY - Berlin, Germany DA - 02.03.2025 KW - MICAP-MS KW - Nitrogen plasma KW - Isotope dilution analysis KW - Matrix tolerance KW - Argon interference elimination KW - Trace analysis PY - 2025 AN - OPUS4-63485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Tavernaro, Isabella A1 - Abram, Sarah-Luise A1 - Homann, Christian A1 - Scholtz, Lena A1 - Radnik, Jörg T1 - Validated and standardized measurements and quantification of surface functionalities on nanoparticles N2 - Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage which improve the quality of life and European prosperity. Nanoparticle function, interaction with biological species, and environmental fate are largely determined by surface functionalities. Reliable, reproducible, and standardized surface characterization methods are therefore vital for quality control of NPs, and mandatory to meet increasing concerns regarding their safety. Also, industry, regulatory agencies, and policymakers need validated traceable measurement methods and reference materials. Industry, e.g., must comply with various regulations, including the chemicals´ regulation REACH (2006/1907) and cosmetic products regulation (2009/1223), depending on the use. Therefore, standardization organizations such as the European Committee for Standardization (CEN), the International Organization for Standardization (ISO), and the International Electrotechnical Commission (IEC) as well as industrial stakeholders, European Medicine Agency (EMA), and the nanosafety community responsible for guidelines for nanomaterial (NM) regulation like the Organisation for Economic Co-operation and Development (OECD) have expressed needs for standardized methodologies to measure NP surface chemical properties. Despite these needs, methodologies for determining NP surface properties, including the amount, chemical composition, and homogeneity of surface functionalities and coatings are largely non-standardized. Specifically, validated quantitative procedures for the measurement of thickness and composition of nanoparticle coatings and other surface functionalities are needed. Suitable methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques such as traceable quantitative nuclear magnetic resonance (qNMR) as well as X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods. The latter less costly methods are often used by SMEs, e.g., for quality control. To validate methods, establish measurement uncertainties, test reference materials, and produce reference data, international interlaboratory comparisons (ILC) on NP surface functionalization measurements are required. These needs have been addressed by us in two interlaboratory comparisons, that will be presented. In addition, the European metrology project SMURFnano will be briefly presented involving 12 partners from different National Metrology Institutes, designated institutes, and research institutes, two university groups as well as one large company and one SME producing NPs. T2 - NanoCarbon Annual Conference 2025 CY - Würzburg, Germany DA - 18.03.2025 KW - Nano KW - Particle KW - Silica KW - Quality assurance KW - Reference material KW - Surface chemistry KW - Size KW - Shape KW - Particle number concentration KW - Method KW - Optical assay KW - QNMR KW - Validation KW - Potentiometry KW - XPS PY - 2025 AN - OPUS4-62790 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tavernaro, Isabella A1 - Abram, Sarah-Luise A1 - Homann, Christian A1 - Scholtz, Lena A1 - Radnik, Jörg A1 - Resch-Genger, Ute T1 - Validated and standardized measurements and quantification of surface functionalities on nanoparticles N2 - Surface-functionalized organic and inorganic engineered nanomaterials (NMs) are widely applied in the life and materials sciences. NM performance depends on key factors such as particle size and shape, crystal phase, morphology, chemical composition, and surface chemistry, i.e., surface coatings, functional groups (FGs), and ligands.1 The latter controls their processability and interaction with the environment and largely their possible toxicity. Thus, methods for FG quantification are important tools for quality control of NM production processes and can foster the sustainable development of functional and safe(r) NMs. This underlines the importance of validated and standardized analytical methods for surface analysis and reference materials.2 This encouraged us to explore simple and versatile tools for quantifying common bioanalytically relevant FGs such as optical assays, electrochemical titration methods, quantitative nuclear magnetic resonance spectroscopy (qNMR), and X-Ray photoelectron spectroscopy (XPS) and to perform a first interlaboratory comparison (ILC) on surface FG quantification.3,4 In a follow-up ILC, BAM and NRC explored qNMR sample preparation, measurement, and data evaluation protocols for commercial and custom-made aminated SiO2 NPs with sizes of 20-100 nm, different amounts of surface amino FGs, and different porosity.5,6 First, the number of amino FGs accessible for a dye reporter was determined with a cost-efficient, automated optical fluorescamine assay. Then, qNMR workflows and protocols were stepwise fine-tuned. The qNMR ILC was complemented by joint XPS measurements. BAM also examined the applicability of fast and automatable potentiometric titrations to screen the total amount of (de)protonable FGs on aminated SiO2 NPs. Our results underline the need to evaluate protocols for FG quantification in ILCs and the advantages of multi-method characterization strategies for efficient method cross validation. T2 - Surface and Micro/Nano Analysis Working Group CY - Paris, France DA - 08.04.2025 KW - Quality assurance KW - Reference material KW - Fluorescence KW - Nano KW - Particle KW - Surface analysis KW - XPS KW - Traceability KW - Metrology KW - Calibration KW - Reference data KW - Reference product KW - Digital certificate KW - QNMR KW - Potentiometry PY - 2025 AN - OPUS4-62969 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -