TY - CONF A1 - Krüger, Y. A1 - Meckler, A. N. A1 - Loland, M. A1 - Day, C. C. A1 - Müller, Bernd R. A1 - Kupsch, Andreas T1 - Fluid inclusion microthermometry in stalagmites: The next stage of development N2 - Fluid inclusion microthermometry is one of the analytical approaches that has been proposed for speleothem-based temperature reconstructions. The proxy of this paleothermometer is the density of drip water relicts that have been enclosed in microscopic fluid inclusions during speleothem growth. Prior to microthermometric analyses, the monophase liquid inclusions need to be transferred from a metastable liquid into a stable liquid-vapour two-phase state by stimulating vapour bubble nucleation by means of single ultra-short laser pulses. Subsequent microthermometric analyses determine the temperature at which the vapour bubble disappears again, the so-called liquid-vapour homogenisation temperature (Th(obs) ). The observed homogenisation temperature depends not only on the water density but also on the inclusion volume. In order to determine the water density, a thermodynamic model is used that takes account of the effect of surface tension on Th(obs) to calculate Th∞. This is the corresponding homogenisation temperature at saturation pressure that determines the water density and defines the formation temperature of the fluid inclusion. The analytical precision of the method ranges between 0.1 and 0.3 °C depending on the size of the inclusions. T2 - Climate Change: The Karst Record IX (KR9) CY - Innsbruck, Austria DA - 17.07.2022 KW - Fluid inclusion microthermometry KW - Stalagmites KW - Synchrotron radiation KW - X-ray imaging KW - X-ray diffraction PY - 2022 AN - OPUS4-55344 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Magkos, Sotirios T1 - Iterative reconstruction from under-sampled Computed Tomography data N2 - In X-ray computed tomography (XCT), an X-ray beam of intensity I0 is transmitted through an object and its attenuated intensity I is measured when it exits the object. The attenuation of the beam depends on the attenuation coefficients along its path. The attenuation coefficients provide information about the structure and composition of the object and can be determined through mathematical operations that are referred to as reconstruction. The standard reconstruction algorithms are based on the filtered backprojection (FBP) of the measured data. While these algorithms are fast and relatively simple, they do not always succeed in computing a precise reconstruction, especially from under-sampled data. Alternatively, an image or volume can be reconstructed by solving a system of linear equations. Typically, the system of equations is too large to be solved but its solution can be approximated by iterative methods, such as the Simultaneous Iterative Reconstruction Technique (SIRT) and the Conjugate Gradient Least Squares (CGLS). This dissertation focuses on the development of a novel iterative algorithm, the Direct Iterative Reconstruction of Computed Tomography Trajectories (DIRECTT). After its reconstruction principle is explained, its performance is assessed for real parallel- and cone-beam CT (including under-sampled) data and compared to that of other established algorithms. Finally, it is demonstrated how the shape of the measured object can be modelled into DIRECTT to achieve even better reconstruction results. KW - Computed tomography KW - DIRECTT KW - Iterative algorithm KW - X-ray imaging KW - Metrics PY - 2022 SP - 1 EP - 94 PB - Universitätsbibliothek Potsdam CY - Potsdam AN - OPUS4-56465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Markötter, Henning A1 - Sintschuk, Michael A1 - Britzke, Ralf A1 - Dayani, Shahabeddin A1 - Bruno, Giovanni T1 - Synchrotron X-Ray Tomography Techniques at BAMline N2 - A recent upgrade of key equipment of the BAMline widens its imaging capabilities: shorter scan acquisition times are now possible, in situ and operando studies can now be routinely performed, and different energy spectra can easily be set up. In fact, the upgraded double-multilayer monochromator brings full flexibility by yielding different energy spectra to optimize flux and energy resolution as desired. T2 - HZB User Meeting CY - Online meeting DA - 08.12.2022 KW - BAMline KW - X-ray imaging KW - Tomography PY - 2022 AN - OPUS4-56568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Markötter, Henning A1 - Sintschuk, Michael A1 - Dayani, Shahab A1 - Serrano Munoz, Itziar A1 - Mishurova, Tatiana A1 - Bruno, Giovanni T1 - Synchrotron X-Ray Tomography Techniques at BAMline N2 - Synchrotron X-Ray computed tomography at the BAMline is constantly evolving. During monochromatic tomographic scans a preview reconstruction is offered. Newly introduced scanning schemes suppress certain types of reconstruction artifacts. Additionally, the application of a pink beam enables for faster tomographic scans even within seconds. T2 - HZB User Meeting CY - Online meeting DA - 09.12.2021 KW - BAMline KW - X-ray imaging KW - Tomography PY - 2021 AN - OPUS4-54075 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Magkos, Sotirios A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Reconstruction of limited-angle projection data with DIRECTT N2 - Direct Iterative Reconstruction of Computed Tomography Trajectories is a fully three-dimensional algorithm that prioritizes the reconstruction of voxels corresponding to dominant trajectories across the projections. T2 - MUMMERING outreach conference CY - Online meeting DA - 10.06.2021 KW - Iteration method KW - X-ray imaging KW - Signal processing KW - Computed tomography PY - 2021 AN - OPUS4-53466 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Magkos, Sotirios A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Suppression of cone-beam artefacts with DIRECTT N2 - A model image of the artefacts is computed just once, but it is used during each iteration of DIRECTT to “correct” the back-projected volume. The final reconstruction is a clear improvement over the one computed by the conventional FDK algorithm. T2 - MUMMERING outreach conference CY - Online meeting DA - 10.06.2021 KW - Iteration method KW - Signal processing KW - X-ray imaging KW - Computed tomography PY - 2021 AN - OPUS4-53467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Magkos, Sotirios A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Suppression of Cone-Beam Artefacts with Direct Iterative Reconstruction Computed Tomography Trajectories (DIRECTT) N2 - The reconstruction of cone-beam computed tomography data using filtered back-projection algorithms unavoidably results in severe artefacts. We describe how the Direct Iterative Reconstruction of Computed Tomography Trajectories (DIRECTT) algorithm can be combined with a model of the artefacts for the reconstruction of such data. The implementation of DIRECTT results in reconstructed volumes of superior quality compared to the conventional algorithms. KW - DIRECTT KW - Iterative method KW - Signal processing KW - X-ray imaging KW - Computed tomography PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-531085 SN - 2313-433X) VL - 7 IS - 8 SP - 147 - 1 EP - 147 -9 PB - MDPI CY - Basel, Switzerland AN - OPUS4-53108 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Markötter, Henning A1 - Sintschuk, Michael A1 - Dayani, Shahabeddin A1 - Serrano Munoz, Itziar A1 - Mishurova, Tatiana A1 - Britzke, Ralf A1 - Müller, Bernd R. A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Tomographic Imaging Capabilities with hard X-Rays at BAMline (Bessy II) N2 - The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers in a wide range of research areas since more than 20 years. These fields include biology, cultural heritage, medicine, and also materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. A recent upgrade of key equipment at the BAMline expands the imaging capabilities towards shorter acquisition times. Therefore, in-situ and operando experiments can now be routinely conducted. Also, different energy resolutions can be set up to optimize flux and energy resolution as desired. This requires an adaptation of the used reconstruction methods in order to perform necessary analyses also during the experiment. In this presentation the equipment, data handling pipeline as well as various examples from material science are presented. T2 - 5th Conference for Research with Synchrotron Radiation, Neutrons and Ion Beams at Large Facilities (SNI 2022) CY - Berlin, Germany DA - 05.09.2022 KW - BAMline KW - X-ray imaging KW - Tomography PY - 2022 AN - OPUS4-55692 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Markötter, Henning A1 - Dayani, Shahabeddin A1 - Müller, Bernd R. A1 - Kupsch, Andreas A1 - Serrano Munoz, Itziar A1 - Sintschuk, Michael A1 - Bruno, Giovanni T1 - Hard X-Ray Imaging Capabilities at BAMline (BESSY II) N2 - The BAMline at the 3rd generation synchrotron X-ray source BESSY II has been supporting researchers in a wide range of research areas for over 20 years. In addition to materials science, these fields also include biology, cultural heritage, and medicine. Being a non-destructive characterization method, synchrotron X-ray imaging, in particular tomography (SXCT), plays a particularly important role in structural characterization. A recent upgrade of key BAMline equipment expands the imaging capabilities: The upgraded dual multilayer monochromator offers flexibility by providing different energy spectra to optimize flux and energy resolution as desired. Different spectra (8 – 60 keV with ΔE/E 0.01%, 1.5%, 4% and pink beam) can be selected. The upgraded detector (in white beam configuration, equipped with an sCMOS camera) allows the higher flux to be exploited with reduced readout times. Shorter tomographic acquisition times in the range of seconds are now possible. Hence, in-situ and operando examinations are routinely available. An integrated slip ring allows continuous rotation of the sample stage for ease of wiring. The pink beam option allows tomographic observation of processes occurring in the time domain of a few seconds with a resolution down to ~ 1 µm. Different scan methods, optimized for quality and speed are available and discussed. Examples of energy related materials from fuel cell and battery research are shown. An optional end station allows refraction enhanced imaging (synchrotron X-Ray refraction radiography (SXRR) and tomography (SXRCT)). That includes an analyzer Si-crystal in Bragg alignment between sample and detector. This technique obtains sensitivity to smaller structures (cracks, pores) down to a few wavelengths, while obtaining field of view sizes in the range of several mm. Besides medicine (e.g., teeth explants), several applications are found in material science, like studies on diesel particulate filters, ceramics, additively manufactured (AM) alloys and metal matrix composites (MMC). The in-situ capabilities include mechanical load (tension and compression) and heating up to 1100°C. A case study, the microstructural evolution during heat treatment of an AM AlSi10Mg, will be shown. T2 - 15th International Conference on X-Ray Microscopy (XRM 2022) CY - Online meeting DA - 19.06.2022 KW - BAMline KW - X-ray imaging KW - Tomography PY - 2022 AN - OPUS4-55691 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Al-Falahat, A.M. A1 - Kupsch, Andreas A1 - Hentschel, M.P. A1 - Lange, A. A1 - Kardjilov, N. A1 - Markötter, Henning A1 - Manke, I. T1 - Correction approach of detector backlighting in radiography N2 - In various kinds of radiography, deficient transmission imaging may occur due to backlighting inside the detector itself arising from light or radiation scattering. The related intensity mismatches barely disturb the high resolution contrast, but its long range nature results in reduced attenuation levels which are often disregarded. Based on X-ray observations and an empirical formalism, a procedure is developed for a first order correction of detector backlighting. A backlighting factor is modeled as a function of the relative detector coverage by the sample projection. Different cases of sample transmission are regarded at different backlight factors and detector coverage. The additional intensity of backlighting may strongly affect the values of materials’ attenuation up to a few 10%. The presented scenario provides a comfortable procedure for corrections of X-ray or neutron transmission imaging data. KW - X-ray imaging KW - Neutron imaging KW - Radiology KW - Backlighting KW - Digital detector array PY - 2019 U6 - https://doi.org/10.1063/1.5097170 SN - 0034-6748 VL - 90 IS - 12 SP - 125108 PB - American Institute of Physics CY - Melville, NY, USA AN - OPUS4-50217 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -