TY - CONF A1 - Wilsch, Gerd A1 - Gottlieb, Cassian A1 - Günther, Tobias A1 - Millar, Steven A1 - Völker, Tobias T1 - Laser-Induced Breakdown Spectroscopy (LIBS) Automated 2D chemical analysis of chloride content in concrete structures N2 - The application of a LIBS system is presented. A diode-pumped low energy laser (3 mJ, 1.5 ns, 100 Hz) and a compact NIR spectrometer are used. A scanner allows the two-dimensional element mapping. For the quantitative analysis calibration of the system is carried out with reference samples in a concentration range of chlorine of 0.05 wt.% to 2.5 wt.%. To determine the 2D distribution of harmful elements (Cl, C), concrete cores were drilled, split and analyzed directly. By comparing the chloride ingress and the carbonation, the interaction of both processes can be visualized in one measurement that takes less than 10 minutes with a drill core of 50 mm x 100 mm. Results obtained were compared and verified with standard measurements. T2 - Concrete Solutions 2019 CY - Cluj Napoca, Romania DA - 30.09.2019 KW - Chloride KW - Beton KW - LIBS KW - Schädigung PY - 2019 AN - OPUS4-51703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -