TY - CONF A1 - Klaus, Christian A1 - Soruco Aloisio, Ricardo A1 - Koch, Claudia A1 - Prellwitz, Matthias T1 - Towards Safety and Accuracy of Hydrogen Refuelling Stations through Digital Twins N2 - This paper presents digital quality infrastructure methods for hydrogen refueling stations using the Asset Administration Shell as a standardized digital twin. Implemented at BAM’s test platform, it integrates real-time sensor data, calibration certificates, and compliance documents to support traceable, interoperable asset management. In combination with AI and semantic tools, the system will enable predictive maintenance, remote audits, and improved safety. This approach reduces downtime, enhances transparency, and offers a scalable model demonstrating the potential of digital twins in advancing metrological traceability and operational efficiency in hydrogen technologies. T2 - IMEKO TC-6 International Conference on Metrology and Digital Transformation - M4DConf 2025 CY - Benevento, Italy DA - 03.09.2025 KW - Datenintregration KW - IT KW - Verwaltungsschale KW - Infrastruktur KW - OT KW - Open Source KW - Software PY - 2025 UR - https://www.m4dconf.org/ UR - https://www.sciencedirect.com/journal/measurement-digitalization SP - 1 EP - 6 AN - OPUS4-64951 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schuhmann, Christoph A1 - Weller, Michael G. A1 - Steglich, Patrick T1 - Multichannel real-time detection of biomarkers with highly miniaturized photonic microchips N2 - The development of novel photonic integrated microchips (PIC) is a promising approach to allow for the convenient detection of key biomarkers in complex matrices through multichannel real-time analysis in a highly compact package. This study reports the successful development and application of a backside released CMOS chip designed for the multichannel real-time detection of biomarkers. Operating at the C-band at approx. 1550 nm, the microchip features three dedicated detection sensors in addition to a reference sensor, enabling simultaneous analysis of multiple biomarkers. The compact and highly miniaturized design of this microchip, with a footprint of just 1 mm², positions it as promising candidate for point-of-care diagnostics and personalized medicine applications. This technology opens a path to transform biomarker detection across various medical fields, offering rapid, reliable, and cost-effective diagnostic solutions. In conclusion, the presented multichannel photonic microchips signify a substantial leap forward in real-time biomarker detection, providing a highly capable platform for future research and clinical applications. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 07.04.2025 KW - Photonic integrated circuit KW - Ring resonator KW - Real-time detection KW - Multiplexing KW - Semiconductor KW - CMOS KW - C-reactive protein KW - CRP KW - Biomarker PY - 2025 SN - 978-1-5106-8850-6 DO - https://doi.org/10.1117/12.3056453 VL - 13527 SP - 1 EP - 6 PB - SPIE CY - Prague, Czech Republic AN - OPUS4-63478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fünning, Tabea A1 - Peczek, Anna A1 - Kroh, Aleksandra A1 - Mai, Christian A1 - Paul, Martin A1 - Thomsen, Florian A1 - Tannenberg, Robert A1 - Schumann, Christoph A1 - Weller, Michael G. A1 - Mai, Andreas A1 - Steglich, Patrick C. ED - Lieberman, Robert A. ED - Baldini, Francesco ED - Homola, Jiri T1 - Optimization of local backside released micro-ring resonators for sensing applications using silicon photonic integrated circuits in a SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 23.05.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching PY - 2025 SN - 978-1-5106-8851-3 DO - https://doi.org/10.1117/12.3056481 VL - 13527 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, Patrick A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schumann, Christoph A1 - Mai, Christian A1 - Tannenberg, Robert A1 - Mai, Andreas ED - Cheben, Pavel ED - Čtyroký, Jiří ED - Molina-Fernández, Iñigo T1 - Towards monolithic integration of polymer-based electro-optical devices in silicon photonic integrated circuits using a 250nm SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 05.06.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching (LBE) PY - 2025 DO - https://doi.org/10.1117/12.3056280 VL - 13530 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klein, Luise A1 - Wilke, Olaf T1 - Chamber comparison for the determination of initial VOC emissions from consumer products N2 - Volatile organic compound (VOC) emissions from consumer products contribute to human inhalation exposure and may cause adverse health effects. Existing methods to determine long-term VOC emissions from e.g. building products need to be verified for their suitability to reliably detect initial VOC emissions from consumer products within the first hours and days of use, which would facilitate realistic inhalation exposure assessments. To investigate this issue, VOCs emitted from a test sample were determined in a large-scale emission test chamber and in two micro-chambers of different volumes, and the results were compared. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Micro-chamber KW - Emission test chamber KW - Volatile organic compounds KW - Inhalation exposure KW - Consumer products PY - 2023 SP - 6 EP - 8 AN - OPUS4-58055 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias T1 - Round robin tests of odour and VOC emissions from building products – What have we learned so far? N2 - Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Perceived intensity KW - VOC-emission KW - Poficiency test KW - Chamber test KW - Odour PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580001 SP - 434 EP - 436 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von Törne, Jannik Wipert A1 - Piechotta, Christian A1 - Karnstedt, L. T1 - Einblicke in das Transformationsverhalten von Warfarin N2 - Warfarin ist seit den 1950er Jahren einer der bekanntesten Gerinnungshemmer. Beim Menschen wird es bis heute zur Vorbeugung von Thrombose und der Behandlung von Vorhofflimmern und Arrhythmie eingesetzt. Doch schon einige Jahre vor der FDA Zulassung (U. S. Food and Drug Administration) als Medikament wurde es zur Bekämpfung von Nagetieren eingesetzt. Bis heute wurde es nur teilweise durch weitaus wirksamere antikoagulante Rodentizide (ARs) der zweiten Generation, sogenannte Superwarfarine, ersetzt. In der Fachliteratur finden sich zahlreiche Beispiele für sekundäre und tertiäre Vergiftung mit ARs bei Wildtieren und anderen Nichtzieltieren. Bisher ist relativ wenig über die Bioakkumulation, Persistenz und Toxizität von ARs und deren Transformationsprodukten (TPs) in der terrestrischen und aquatischen Umwelt, sowie der Nahrungskette bekannt. Um Einblicke in mögliche Transformations- und Abbauprozesse von Warfarin unter umweltrelevanten Bedingungen zu erhalten und um diese Einflüsse zu simulieren, wurde hierzu eine elektrochemische Reaktorzelle in Kopplung mit einem Massenspektrometer verwendet. So können mögliche Phase-I-Metabolite und sogenannte „oxidation products“ vorausgesagt werden. Hinsichtlich des Verhaltens während der Wasseraufbereitung in Kläranlagen wurden technisch relevante Prozesse wie Chlorung, UV-Bestrahlung und Ozonung in Modellen simuliert, um hier potenzielle Abbauwege und -prozesse aufzuklären. Gebildete Transformationsprodukte wurden daher mittels unterschiedlicher chromatografischer Verfahren getrennt und massenspektrometrisch identifiziert, charakterisiert und verglichen. T2 - 49. Jahrestagung der GUS 2020 CY - Stutensee, Blankenloch DA - 24.03.2021 KW - Warfarin KW - Transformationsprodukte KW - Umweltverhalten PY - 2021 SN - 978-3-9818507-6-5 VL - 49 SP - 265 EP - 272 AN - OPUS4-53963 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, P. A1 - Mai, C. A1 - Bondarenko, S. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Schrader, S. A1 - Mai, A. T1 - BioPIC - Integration of Biosensors based on Photonic Integrated Circuits by Local-Backside Etching N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. T2 - ATTRACT online Conference CY - Online meeting DA - 22.09.2020 KW - Silicon Photonics KW - Photonic Sensor KW - Photonic Integrated Circuits KW - Point-Of-Care-Diagnostics KW - CMOS KW - Microfluidics KW - Lab-on-a-chip KW - Ring resonator PY - 2020 UR - https://attract-eu.com/showroom/project/integration-of-biosensors-based-on-photonic-integrated-circuits-by-local-backside-etching-biopic/ SP - 1 EP - 5 AN - OPUS4-51735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -