TY - CONF A1 - Mirtsch, Mona A1 - Pohlisch, Jakob A1 - Blind, K. T1 - International Diffusion of the Information Security Management System Standard ISO/IEC 27001: Exploring the Role of Culture N2 - In the wake of digitalization, organizations are increasingly exposed to risks associated with security breaches and must take measures to preserve the confidentiality, integrity, and availability of information, and to ensure business continuity. The international standard ISO/IEC 27001 assists organizations in setting up, maintaining and continuously improving their information security management systems. However, despite high growth rates, its international diffusion rates are quite heterogeneous. This paper explores why the diffusion of the international management system standard ISO/IEC 27001 differs across countries. We classify the adoption of ISO/IEC 27001 as a ‘preventive organizational innovation’ and draw from diffusion studies of other management system standards and information security research to develop a set of hypotheses. These relate to the impact of cultural dimensions and national ICT development. We use a negative binomial regression model with panel data covering 57 countries over a 12-year period from 2006 to 2017 to test our hypotheses. We find that the cultural dimensions future orientation, power distance, and institutional collectivism as well as high ICT development are driving factors for the diffusion of ISO/IEC 27001. We derive policy recommendations and avenues for future research. T2 - Twenty-Eighth European Conference on Information Systems (ECIS2020) – A Virtual AIS Conference CY - Online meeting DA - 15.06.2020 KW - Information security KW - International diffusion KW - Standards KW - Management system standards KW - ISO/IEC 27001 KW - Preventive innovations KW - Culture KW - GLOBE KW - ICT development index PY - 2020 SP - RP 88 AN - OPUS4-50919 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mirtsch, Mona T1 - International Diffusion of the Information Security Management System Standard ISO/IEC 27001: Exploring the role of culture N2 - In the wake of digitalization, organizations are increasingly exposed to risks associated with security breaches and must take measures to preserve the confidentiality, integrity, and availability of information, and to ensure business continuity. The international standard ISO/IEC 27001 assists organizations in setting up, maintaining and continuously improving their information security management systems. However, despite high growth rates, its international diffusion rates are quite heterogeneous. This paper explores why the diffusion of the international management system standard ISO/IEC 27001 differs across countries. We classify the adoption of ISO/IEC 27001 as a ‘preventive organizational innovation’ and draw from diffusion studies of other management system standards and information security research to develop a set of hypotheses. These relate to the impact of cultural dimensions and national ICT development. We use a negative binomial regression model with panel data covering 57 countries over a 12-year period from 2006 to 2017 to test our hypotheses. We find that the cultural dimensions future orientation, power distance, and institutional collectivism as well as high ICT development are driving factors for the diffusion of ISO/IEC 27001. We derive policy recommendations and avenues for future research. T2 - Twenty-Eighth European Conference on Information Systems (ECIS2020) – A Virtual AIS Conference CY - Online meeting DA - 15.06.2020 KW - Information security KW - International diffusion KW - Standards KW - Management system standards KW - ISO/IEC 27001 KW - Preventive innovations KW - Culture KW - GLOBE KW - ICT development index PY - 2020 AN - OPUS4-50921 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Faßbender, Sebastian T1 - On-line species-specific isotopic analysis of sulfur by hyphenation of capillary electrophoresis with MC-ICP-MS N2 - In many scientific fields, isotopic analysis can offer valuable information. Up to date, typically bulk analysis is aimed at measuring the isotopic composition of the entire elemental content of the sample. However, the analyte element is usually present under the form of different species. Thus, separating species of interest from one another and from matrix components prior to isotope ratio measurements can provide species-specific isotopic information, which could be used for tracing the origin of environmental pollutants and elucidation of (environmental) speciation. Using on-line hyphenations of separation techniques with multicollector-ICP-MS (MC-ICP-MS) can save time and effort and enables the analysis of different species during a single measurement. Whereas some works hyphenating GC and IC with MC-ICP-MS have already been reported, LC and CE hyphenations are still inadequately represented based on the capabilities of these separation techniques. In this work, we developed an on-line hyphenation of CE with multicollector-ICP-MS (CE/MC-ICP-MS) for isotopic analysis of sulfur species using a multiple-injection approach for instrumental mass bias correction by standard-sample bracketing. With this method, the isotopic composition of sulfur in sulfate originating from river water could be analyzed without sample preparation. The results were compared to data from off-line analysis of the same samples to ensure accuracy. The precision of the results of the on-line measurements was promising regarding the differentiation of the river systems by the isotopic signature of river water sulfate. The great potential of this method is based on the versatility of the applied separation technique, not only in the environmental field but also for, e.g., biomolecules, as sulfur is the only covalently bound constituent of proteins that can be analyzed by MC-ICP-MS. T2 - Virtual Goldschmidt 2020 CY - Online meeting DA - 21.06.2020 KW - Isotopic analysis KW - Hyphenated techniques KW - Capillary electrophoresis KW - Multicollector-ICP-MS KW - Speciation analysis PY - 2020 AN - OPUS4-50922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kuhring, M. A1 - Doellinger, J. A1 - Nitsche, A. A1 - Muth, Thilo A1 - Renard, B. Y. T1 - TaxIt: An Iterative Computational Pipeline for Untargeted Strain-Level Identification Using MS/MS Spectra from Pathogenic Single-Organism Samples N2 - Untargeted accurate strain-level classification of a priori unidentified organisms using tandem mass spectrometry is a challenging task. Reference databases often lack taxonomic depth, limiting peptide assignments to the species level. However, the extension with detailed strain information increases runtime and decreases statistical power. In addition, larger databases contain a higher number of similar proteomes. We present TaxIt, an iterative workflow to address the increasing search space required for MS/MS-based strain-level classification of samples with unknown taxonomic origin. TaxIt first applies reference sequence data for initial identification of species candidates, followed by automated acquisition of relevant strain sequences for low level classification. Furthermore, proteome similarities resulting in ambiguous taxonomic assignments are addressed with an abundance weighting strategy to increase the confidence in candidate taxa. For benchmarking the performance of our method, we apply our iterative workflow on several samples of bacterial and viral origin. In comparison to noniterative approaches using unique peptides or advanced abundance correction, TaxIt identifies microbial strains correctly in all examples presented (with one tie), thereby demonstrating the potential for untargeted and deeper taxonomic classification. TaxIt makes extensive use of public, unrestricted, and continuously growing sequence resources such as the NCBI databases and is available under open-source BSD license at https://gitlab.com/rki_bioinformatics/TaxIt. KW - Bioinformatics KW - Mass spectrometry KW - Microbial proteomics KW - Strain identification KW - MS/MS PY - 2020 DO - https://doi.org/10.1021/acs.jproteome.9b00714 VL - 19 IS - 6 SP - 2501 EP - 2510 PB - ACS AN - OPUS4-50942 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Sennikov, P. A1 - Kornev, R. A1 - Ermakov, A. A1 - Shkrunin, V. T1 - Laser Induced Dielectric Breakdown for Chemical Vapor Deposition by Hydrogen Reduction of Volatile Boron Halides BCl3 and  BF3 N2 - A possibility of deposition from laser-induced plasma is investigated in search for an economic and simple method for obtaining isotopic compounds from enriched gaseous precursors although no isotopic compounds are used in this the proof-of-principle work. A breakdown in mixtures of BCl3 and BCl3 with hydrogen, argon, and methane are studied both theoretically and experimentally. Equilibrium chemistry calculations show the deposition of boron, boron carbide, and carbon is thermodynamically favorable in BCl3 systems and only carbon in BF3 systems. Dynamic calculation of expanding plasma is performed using fluid dynamics coupled with equilibrium chemistry. Condensed phases of boron, boron carbide, and graphite are predicted with maximum concentrations in peripheral zones of the plasma. In experiment, plasma is induced in mixtures BCl3, H2 + BCl3, H2 + Ar + BCl3, H2 + BCl3 + CH4, BF3, H2 + BF3, H2 + Ar + BF3, and H2 + Ar + BF3. The gases are analyzed before, during, and after laser irradiation by optical and mass spectrometry methods. The results show the composition of reaction products close to that predicted theoretically. The conversion of precursor gases BCl3 and BF3 into gaseous and condensed products is 100% for BCl3 and 80% for BF3. Solid deposits of up to 30 mg are obtained from all reaction mixtures. Due to technical reasons only FTIR characterization of the BCl3 + H2 + CH4 deposit is done. It points to presence of condensed boron and boron carbide predicted by the model. Overall, the calculations and preliminary experimental results imply the chemical vapor deposition with laser induced plasma is promising for conversion of gaseous enriched precursors into elemental isotopes and their isotopic compounds. KW - Boron halides KW - Chemical vapor deposition KW - Laser induced dielectric breakdown, Hydrogen reduction PY - 2020 DO - https://doi.org/10.1007/s11090-020-10096-w VL - 40 IS - 5 SP - 1145 EP - 1162 PB - Springer AN - OPUS4-50968 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kruschwitz, Sabine T1 - Challenges in Intelligent Computing for Non destructive testing in civil engineering – today and tomorrow N2 - A large amount of data and information is collected in the field of non-destructive testing (NDT) in civil engineering. The weakly structured data are usually evaluated with regard to specific testing tasks (e.g. geometry determination, damage localization, quality assurance). While the data offers great economic potential, i.e. to support construction planning, monitoring and maintenance processes, the evaluation is manual and case-by-case and therefore too inefficient for broader applications. We present recent visions and approaches how these large amounts of data need to be handled in the future and how we aim to make the acquired knowledge accessible to our stakeholders. Building on initiatives in materials research, we stress the importance of further research in the field of semantic data integration particularly motivate why an ontology is needed for the area of NDT in civil engineering. T2 - EG-ICE 2020 CY - Online meeting DA - 01.07.2020 KW - Data analysis KW - Non destructive testing KW - Computational engineering KW - AI PY - 2020 AN - OPUS4-50971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ahmadi, Samim A1 - Burgholzer, P. A1 - Jung, P. A1 - Caire, G. A1 - Ziegler, Mathias T1 - Super resolution laser line scanning thermography N2 - In this paper we propose super resolution measurement and post-processing strategies that can be applied in thermography using laser line scanning. The implementation of these techniques facilitates the separation of two closely spaced defects and avoids the expected deterioration of spatial resolution due to heat diffusion. The experimental studies were performed using a high-power laser as heat source in combination with pulsed thermography measurements (step scanning) or with continuous heating measurements (continuous scanning). Our work shows that laser line step scanning as well as continuous scanning both can be used within our developed super resolution (SR) techniques. Our SR techniques make use of a compressed sensing based algorithm in post- processing, the so-called iterative joint sparsity (IJOSP) approach. The IJOSP method benefits from both - the sparse nature of defects in space as well as from the similarity of each measurement. In addition, we show further methods to improve the reconstruction quality e.g. by simple manipulations in thermal image processing such as by considering the effect of the scanning motion or by using different optimization algorithms within the IJOSP approach. These super resolution image processing methods are discussed so that the advantages and disadvantages of each method can be extracted. Our contribution thus provides new approaches for the implementation of super resolution techniques in laser line scanning thermography and informs about which experimental and post-processing parameters should be chosen to better separate two closely spaced defects. KW - Super resolution KW - Laser thermography KW - Compressed sensing KW - Laser scanning KW - Joint sparsity PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509796 DO - https://doi.org/10.1016/j.optlaseng.2020.106279 SN - 0143-8166 VL - 134 SP - 106279 PB - Elsevier Ltd. AN - OPUS4-50979 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rus, J. A1 - Gustschin, A. A1 - Mooshofer, H. A1 - Grager, J.-C. A1 - Bente, Klaas A1 - Gaal, Mate A1 - Pfeiffer, F. A1 - Grosse, C. U. T1 - Qualitative comparison of non-destructive methods for inspection of carbon fiber-reinforced polymer laminates N2 - In the rapidly expanding composite industry, novel inspection methods have been developed in recent years. Particularly promising for air-coupled testing are cellular polypropylene transducers which offer better impedance matching to air than piezoelectric transducers. Furthermore, broadband transmitters (laser-induced ultrasound and thermoacoustic emitters) and receivers (optical microphones) have opened a completely new chapter for advanced contact-free ultra-sound inspection. X-ray dark-field radiography offers a different approach to detect porosity and microcracks, employing small angle X-ray scattering. These innovative ultrasonic and radiographic alternatives were evaluated in comparison with well-established inspection techniques. We applied thirteen different non-destructive methods to inspect the same specimen (a carbon fiber-reinforced polymer laminate with induced impact damage): air-coupled ultrasound testing (using piezoelectric transducers, broadband optical microphones, cellular polypropylene transducers, and a thermoa- coustic emitter), laser-induced ultrasound testing, ultrasonic immersion testing, phased array ultrasonic testing, optically excited lock-in thermography, and X-ray radiography (projectional absorption and dark-field, tomosynthesis, and micro-computed tomography). The inspection methods were qualitatively characterized by comparing the scan results. The conclusions are advantageous for a decision on the optimal method for certain testing constraints. KW - Carbon fiber-reinforced polymer KW - Air-coupled ultrasound KW - Optically excited lock-in thermography KW - X-ray micro-computed tomography KW - X-ray dark-field radiography PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509473 DO - https://doi.org/10.1177/0021998320931162 SN - 0021-9983 VL - 54 IS - 27 SP - 4325 EP - 4337 PB - SAGE AN - OPUS4-50947 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tiitta, M. A1 - Tiitta, V. A1 - Gaal, Mate A1 - Heikkinen, J. A1 - Lappalainen, R. A1 - Tomppo, L. T1 - Air-coupled ultrasound detection of natural defects in wood using ferroelectret and piezoelectric sensors N2 - Air-coupled ultrasound was used for assessing natural defects in wood boards by through-transmission scanning measurements. Gas matrix piezoelectric (GMP) and ferroelectret (FE) transducers were studied. The study also included tests with additional bias voltage with the ferroelectret receivers. Signal analyses, analyses of the measurement dynamics and statistical analyses of the signal parameters were conducted. After the measurement series, the samples were cut from the measurement regions and the defects were analyzed visually from the cross sections. The ultrasound responses were compared with the results of the visual examination of the cross sections. With the additional bias voltage, the ferroelectret measurement showed increased signal-to-noise ratio, which is especially important for air-coupled measurement of high-attenuation materials like wood. When comparing the defect response of GMP and FE sensors, it was found that FE sensors had more sensitive dynamic range, resulting from better s/n ratio and short response pulse. Classification test was made to test the possibility of detecting defects in sound wood. Machine learning methods including decision trees, k-nearest neighbor and support vector machine were used. The classification accuracy varied between 72 and 77% in the tests. All the tested machine learning methods could be used efficiently for the classification. KW - Air-coupled transducers KW - Wood KW - Ultrasound KW - Ultrasonic imaging KW - Ferroelectret KW - Machine learning PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509503 DO - https://doi.org/10.1007/s00226-020-01189-y SP - 1 EP - 14 PB - Springer AN - OPUS4-50950 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Haas, Marko ED - Hirsch, B ED - Weber, J ED - Schäfer, F ED - Schmid, J T1 - Das Risikomanagementsystem in der Bundesanstalt für Materialforschung und -prüfung (BAM) N2 - Im Rahmen des Bandes Management von Risiken in Behörden beschreibt der Praxisbeitrag das Risikomanagementsystem der BAM. KW - Risiko KW - Risikomanagement KW - Controlling KW - Management KW - Steuerung PY - 2020 SN - 978-3-503-19150-5 SP - 90 EP - 100 PB - Erich Schmidt Verlag CY - Berlin AN - OPUS4-50915 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -