TY - CONF A1 - Brence, Blaž A1 - Bulling, Jannis A1 - Lugovtsova, Yevgeniya A1 - Kraemer, P. A1 - Prager, Jens T1 - Determination of a notch depth using ultrasonic guided waves N2 - In non-destructive testing and structural health monitoring, ultrasonic guided waves (UGWs) are of great interest for finding and characterizing structural flaws. The interaction of the waves with the flaws can often not be described analytically due to waves’ complexity. This makes numerical simulations and experiments indispensable. However, mentioned field of research is still relatively young and most of the methods focus on flaw localization, using time of flight of the reflected signal. This leaves many possibilities for further research, especially when it comes to separate analysis of different propagating modes. It is well-known that ultrasonic wave modes convert when interacting with flaws. When a fundamental mode (A0 or S0) encounters a notch, it interacts and converts to another fundamental mode. In this contribution, this effect is used to analyze the depth of a notch. Firstly, numerical simulations are presented, which show notch depth proportionality to amplitude ratio of fundamental modes. To validate these results, experiments were carried out on a metal plate with a shallow notch which was gradually deepened. UGWs were excited using a polymer-based interdigital transducer (IDT) and detected with a 3D laser Doppler vibrometer. The IDT is employed to ensure excitation of a single mode and thus to reduce the complexity of the analysis. Good agreement between numerical and experimental results has been found. The results show the potential of UGWs not only for defect reconstruction and localization, but also its precise sizing. T2 - 10th European Workshop on Structural Health Monitoring (EWSHM 2022) CY - Palermo, Italy DA - 04.07.2022 KW - Lamb waves KW - Numerical simulation KW - Selective excitation PY - 2022 AN - OPUS4-55502 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - A Long Way of Plasma Modeling: Personal Experience N2 - Modeling is an important tool for understanding a physical phenomenon. It helps to interpret results of experiments and optimize experimental parameters for obtaining a desirable result. Modeling laser induced plasma is beneficial for many scientific and industrial fields, e.g., analytical chemistry, pulsed laser deposition, plasma enhanced chemical vapor deposition, laser welding, additive manufacturing etc. In this presentation, a personal experience in development of a physical model of laser induced plasma will be given in a chronological sequence starting from early 2000th and until now. Over the time, the model evolved from its simple analytical form that described plasma emission spectra to its current numerical form that describes plasma dynamics, chemistry, and interaction with a substrate surface. Several examples will be given for the application of the model to practical problems such as spectroscopic chemical analysis, plasma enhanced chemical vapor deposition, and surface modification by laser ablation. T2 - XII World Conference on Laser Induced Breakdown Spectroscopy CY - Bari, Italy DA - 05.09.2022 KW - Laser induced plasma KW - CFD computational fluid dynamic KW - Plasma modeling KW - Plasma chemistry PY - 2022 AN - OPUS4-55669 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völker, Tobias A1 - Wilsch, Gerd A1 - Gornushkin, Igor B. A1 - Millar, S. A1 - Licht, M. T1 - Interlaboratory comparison for quantitative chlorine analysis in cement pastes with LIBS N2 - Concrete structures often show severe damage during their lifetime. One such damage is pitting corrosion of the steel reinforcement caused by chloride ingress into the porous concrete structure. Laser-induced breakdown spectroscopy (LIBS) is a promising method in civil engineering, which is used for detection of chlorine in concrete structures in addition to conventional methods of wet chemistry. To assess LIBS as a trustful analytical technique, its accuracy and robustness is carefully tested. The presentation will outline the results of the interlaboratory comparison of chlorine quantification in cement paste samples, which was carried out by 12 laboratories in 10 countries. Two sets of samples with chloride content ranging from 0.06-1.95 wt.% in the training set and 0.23-1.51 wt.% in the test sample set (“unknowns”), with additional variations in the type of cement and chlorine source (salt type) were sent to the laboratories. The overall result demonstrates that LIBS is suitable for the quantification of the investigated sample compositions: average relative bias was mostly below 15 %. Considering that the laboratories did not receive instructions on how to perform the analysis or how to process the data, the results can be evaluated as a true status quo of the LIBS technique for this type of analysis. T2 - XII Laser Induced Breakdown Spectroscopy (LIBS 2022) CY - Bari, Italy DA - 04.09.2022 KW - LIBS KW - Chlorine KW - Cement pastes KW - Interlaboratory comparison PY - 2022 AN - OPUS4-55680 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen A1 - Oelze, Marcus A1 - Rosner, M. A1 - Rienitz, O. T1 - Isotope reference materials N2 - The variation of isotope ratios is increasingly used to unravel natural and technical questions. In the past, the investigation and interpretation of such variations was the field of a limited number of experts. With new upcoming techniques and research topics in the last decades, such as provenance or food authenticity studies, the number of published isotope data strongly increased. Instrumental developments such as the enhancement of inductively coupled plasma mass spectrometers (ICP-MS) from an instrument for simple quantitative analysis to highly sophisticated isotope ratio machines influenced this process significantly. While in former times only experts in mass spectrometry were able to produce reliable isotope data, nowadays many laboratories, never been in touch with mass spectrometry before, produce isotope data with an ICP-MS. Isotope reference materials (iCRM) are indispensable to enable a reliable method validation or in rare cases even SI-traceability. The fast development and the broad availability of ICP-MS also lead to an expansion of the classical research areas and new elements are under investigation. Irrespective of the investigated element or the knowledge of the user all isotope ratio applications require reference materials either for correction of instrumental isotope fractionation, for method validation or to provide a common accepted basis as needed for delta measurements. This presentation will outline the basic principles and illustrate the urgent need for new iCRMs. Consequently, the production and certification of iCRMs will be discussed and illustrated by examples of already completed certification projects. Finally, plans for future iCRMs to be produced at BAM will be presented. T2 - ICP-MS Anwender*innentreffen 2022 CY - Leoben, Austria DA - 05.09.2022 KW - Absolute isotope ratio KW - Traceability KW - Metrology KW - Comparability KW - Uncertainty KW - Isotope reference materials KW - Delta scale PY - 2022 AN - OPUS4-55681 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Standardized workflow for checking the performance of an EDS X-ray spectrometer at a Scanning Electron Microscope N2 - For test laboratories operating under accreditation schemes like ISO/IEC 17025 (ISO/IEC 17025), as the international reference for testing and calibration laboratories wanting to demonstrate their capacity to deliver reliable results, a periodical control of the critical instrumental parameters of an Energy-Dispersive X-ray Spectrometer (EDS) is required. This periodical check of an EDS is specified with exact procedures and materials in the ISO 15632:2021 ”Microbeam Analysis – Selected instrumental performance parameters for the specification and checking of energy-dispersive X-ray spectrometers for use in electron probe microanalysis” (ISO 15632). The EDS check can be simplified to the acquisition of only one 10 kV spectrum from a dedicated test material, EDS-TM002, which is made available by BAM since 2009 (https://webshop.bam.de/webshop_en/). The optional BAM software “EDX spectrometer check” is destined to automatically evaluate this spectrum and determine the performance of the EDS in terms of energy resolution and calibration, as well as possible alteration of low-energy efficiency due to detector contamination. Nearly 200 laboratories have the EDS-TM and associated software package in use. Practical examples based on various types of artifacts occurred in the EDS spectra and a long-term (>10 years) meticulous observation of the own spectrometers will be discussed. Different types of EDS spectrometers are considered, e.g. Si(Li) and SDD, of various window types (AP, the recent one Si3N4 or even windowless), and with different front contact layers (Au and Ni) (Hodoroaba and Procop, 2014). Evaluation of other parameters or effects such as the deadtime at different count rates or pileup effects is also explained with examples. T2 - Workshop "Automated Mineralogy" @ GEOANALYSIS 2022 CY - Freiberg, Germany DA - 06.08.2022 KW - EDS KW - X-ray spectrometer KW - Performance check KW - Test material KW - Standardized check KW - EDS-TM002 PY - 2022 UR - https://geoanalysis2021.de/en/workshops/automated-mineralogy AN - OPUS4-55460 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Evsevleev, Sergei A1 - Sevostianov, I. A1 - Mishurova, Tatiana A1 - Cabeza, S. A1 - Koos, R. A1 - Hofmann, M. A1 - Requena, G. A1 - Garcés, G. T1 - Damage and stress evolution in multi-phase metal matrix composites N2 - While there is a extensive literature on the micro-mechanical behavior of metal matrix composites (MMCs) under uniaxial applied stress, very little is available on multi-phase MMCs. In order to cast light on the reinforcement and damage processes in such multi-phase composites, an Al alloy with one and two ceramic reinforcements (planar-random oriented alumina fibers and SiC particles) were studied. In-situ compression tests during neutron diffraction experiments were used to track the load transfer among phases, while X-ray computed tomography was used to investigate pre-strained samples, in order to monitor and quantify damage. We found that damage progresses differently in composites with different orientations of the fiber mat. Because of the presence of the intermetallic network, it was observed that the second ceramic reinforcement changes the load transfer scenario only at very high applied load, when also intermetallic particles break. We rationalized the experimental results by means of a micromechanical model based on Maxwell’s homogenization scheme, and we could explain why no damage is observed in the ductile matrix under compression: the matrix finds itself in hydrostatic compression, and the Poisson’s tensile strain is totally carried by the reinforcement phases T2 - CIMTEC CY - Perugia, Italy DA - 20.06.2022 KW - Load transfer KW - Neutron Diffraction KW - Michromechanical modeling KW - Computed Tomography KW - Machine Learning PY - 2022 AN - OPUS4-55404 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Evsevleev, Sergei A1 - Sevostianov, I. A1 - Mishurova, Tatiana A1 - Cabeza, S. A1 - Koos, R. A1 - Hofmann, M. A1 - Requena, G. A1 - Garcés, G. T1 - Explaining deviatoric residual stresses and load transfer in aluminum alloys and composites with complex microstructure N2 - The residual stresses and load transfer in multiphase metal alloys and their composites (with both random planar-oriented short fibers and particles) will be shown, as studied by neutron diffraction, by X-ray computed tomography, and by a model based on the reformulation of classic Maxwell’s homogenization method. Contrary to common understanding and state-of-the-art models, we experimentally observe that randomly oriented phases possess non-hydrostatic residual stress. Moreover, we disclose that the unreinforced matrix alloy stays under hydrostatic compression even under external uniaxial compression. The recently developed modeling approach allows calculating the residual stress in all phases of the composites. It rationalizes the presence of deviatoric stresses accounting for the interaction of random oriented phases with fibers having preferential orientation. It also allows the explanation of the unconventional in-situ behavior of the unreinforced alloy and the prediction of the micromechanical behavior of other similar alloys. T2 - MLZ Conference 2022: Neutrons for Mobility CY - Lenggries, Germany DA - 31.05.2022 KW - Load transfer KW - Neutron Diffraction KW - micromechanical modeling KW - Computed tomography PY - 2022 AN - OPUS4-55405 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lugovtsova, Yevgeniya A1 - Memmolo, V. A1 - Olino, M. A1 - Prager, Jens T1 - Application of Temperature Compensation Strategies for Ultrasonic Guided Waves to Distributed Sensor Networks N2 - The application of temperature compensation strategies is crucial in structural health monitoring approaches based on guided waves. Actually, the varying temperature influences the performance of the inspection system inducing false alarms or missed detection, with a consequent reduction of reliability and impact on probability of detection (POD). This paper quantitatively describes two different methods to compensate the temperature effect, namely the optimal baseline selection (OBS) and the baseline signal stretch (BSS) extending their application to the case of a distributed sensor networks (DSN). This latter introduces a number of possible data to explore compensation strategies which do not necessarily returns univocal results. Hence, a decision framework is needed, which takes into consideration multiple ultrasonic time traces with different arrival times and amplitude. In detail, the effect of temperature separation between baseline time-traces in OBS are investigated considering multiple couples of sensors employed in the DSN. A combined strategy that uses both OBS and a frequent value warning is introduced to find the more probable temperature with increasing reliability of the assessment. The same procedure is applied using the BSS algorithm. Finally, the use of both approaches is introduced, comparing the capability of the mixed algorithm to correctly sort temperature information from OBS and then apply the BSS combining the frequent value warning to have a unique correction all over the DSN. Theoretical results are compared, using data from two several experiments, which use different frequency analysis with either predominantly A0 mode or S0 mode data or both. The focus is given on the fact that different paths are available in a sensor network and several possible combinations of results are available. Nonetheless, introducing a frequent value warning it is possible to increase the efficiency of the OBS and BSS approaches making use of fewer signal processing algorithms. These confirm that the performance of OBS quantitatively agrees with predictions. In addition, the possibility to combine BSS approached also demonstrates that the use of compensation strategies improves detectability and localization of damage even in a DSN. This result can be used to improve the SHM system reliability, with promising perspectives in increasing POD. T2 - ASME 2022 49th Annual Review of Progress in Quantitative Nondestructive Evaluation (QNDE2022) CY - San Diego, CA, USA DA - 25.07.2022 KW - Performance assessment KW - Elastic waves KW - Structural Health Monitoring PY - 2022 AN - OPUS4-55427 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kröll, Mirco A1 - Grundtner, R. A1 - Pagano, F. A1 - Nyberg, E. A1 - Heino, V. A1 - Spaltmann, Dirk A1 - Gradt, Thomas T1 - Effects of harmonised procedures in tribology testing N2 - i-TRIBOMAT will provide the world's first Open Innovation Test Bed dedicated to analysing and simulating materials in tribological systems. In order to make necessary results of tribological tests comparable, harmonised ways to produce data are mandatory. Many sources influence the outcome of a Tribological test. Different approaches of institutes were evaluated in best practices via quality management tools minimising the impact on results. T2 - 7th World Tribology Congress - WTC 2022 CY - Lyon, France DA - 11.07.2022 KW - Tribology KW - i-TRIBOMAT KW - Characterisation KW - Digitalisation KW - Harmonisation KW - Round robin tests KW - Interlaboratory tests PY - 2022 AN - OPUS4-55317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zabala, A. A1 - Aginagalde, A. A1 - Llavori, I. A1 - Spaltmann, Dirk A1 - Blunt, L. T1 - Ball-on-flat linear reciprocating tests: Critical assessment of wear volume determination methods N2 - This work presents a critical assessment of wear volume determination methods for ball-on-flat linear reciprocating sliding tribological tests. T2 - 7th World Tribology Congress - WTC 2022 CY - Lyon, France DA - 11.07.2022 KW - Wear KW - Sliding KW - Surface KW - Analysis PY - 2022 AN - OPUS4-55319 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lugovtsova, Yevgeniya A1 - Bulling, Jannis A1 - Prager, Jens T1 - Towards Characterisation of Elastic Constants of Composite Materials by means of Ultrasonic Guided Waves N2 - The availability of non-destructive methods is particularly important for composites, e.g., carbon or glass fiber-reinforced polymers because their properties strongly depend on the manufacturing process and in-service conditions. Composites are mostly used in thin-walled components which are perfectly suited for the characterisation with ultrasonic guided waves (UGWs). In this contribution, we demonstrate sensitivities of UGW to different elastic constants of a composite material. Then we present a characterisation procedure which can be used to in-fer elastic properties. Our approach is based on an inverse procedure in which the numeri-cally calculated dispersion curves are fitted to the measured curves. The acquisition is done by applying a broadband piezoelectric transducer (PZT) to excite various UGW modes and a 3D laser Doppler vibrometer (3D LDV) to record them. Compared to the approaches based on laser excitation, the PZT provides a better signal-to-noise ratio because more energy is brought into the structure. Whereas the 3D LDV compared to a 1D LDV or a PZT allows cap-turing in-plane and out-of-plane components giving more dispersion information for a better characterisation. Since the inverse procedure requires many iterations before elastic prop-erties are retrieved, an efficient tool for the calculation of the dispersion curves is necessary. For this, the Scaled Boundary Finite Element Method is used. All in all, a good agreement be-tween theoretical and experimental curves is demonstrated. T2 - ASME 2022 49th Annual Review of Progress in Quantitative Nondestructive Evaluation (QNDE2022) CY - San Diego, CA, USA DA - 25.07.2022 KW - Carbon fibre reinforced polymer KW - Glass fibre reinforced polymer KW - Inverse procedure PY - 2022 AN - OPUS4-55425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Geophysical methods delivering input to geostatistical methods for geotechnical site characterization N2 - Geophysical methods are able to contribute significantly to geotechnical site characterization. In-situ parameters are collected and gaps between boreholes or other direct tests are filled with information. However the limited resolution has to be considered and the indirect geophysical parameters have to be translated into something geotechnically useful. Moreover, the limitations have to be evaluated when including geophysical data into geostatistical models. If done properly, the use of geophysics will help in an efficient and effective site characterization. A comprehensive overview on existing geophysical (mostly seismic) methods is given as well as information on the calibration of geophysical against geotechnical parameters, pitfalls and limitations and some hints how to include these data into geostatistical/geotechnical models. T2 - ICGoES International Conference on Geologicalk Engineering and Geosciences CY - Yogyakarta, Indonesia DA - 21.09.2022 KW - Geophysics KW - Geostatistics KW - Geotechnics PY - 2022 AN - OPUS4-55806 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob T1 - The Human Factor: Results of a Data Analysis Round Robin N2 - How much do we, the small-angle scatterers, influence the results of an investigation? What uncertainty do we add by our human diversity in thoughts and approaches, and is this significant compared to the uncertainty from the instrumental measurement factors? After our previous Round Robin on data collection, we know that many laboratories can collect reasonably consistent small-angle scattering data on easy samples1. To investigate the next, human component, we compiled four existing datasets from globular (roughly spherical) scatterers, each exhibiting a common complication, and asked the participants to apply their usual methods and toolset to the quantification of the results https://lookingatnothing.com/index.php/archives/3274). Accompanying the datasets was a modicum of accompanying information to help with the interpretation of the data, similar to what we normally receive from our collaborators. More than 30 participants reported back with volume fractions, mean sizes and size distribution widths of the particle populations in the samples, as well as information on their self-assessed level of experience and years in the field. While the Round Robin is still underway (until the 25th of April, 2022), the initial results already show significant spread in the results. Some of these are due to the variety in interpretation of the meaning of the requested parameters, as well as simple human errors, both of which are easy to correct for. Nevertheless, even after correcting for these differences in understanding, a significant spread remains. This highlights an urgent challenge to our community: how can we better help ourselves and our colleagues obtain more reliable results, how could we take the human factor out of the equation, so to speak? In this talk, we will introduce the four datasets, their origins and challenges. Hot off the press, we will summarize the anonymized, quantified results of the Data Analysis Round Robin. (Incidentally, we will also see if a correlation exists between experience and proximity of the result to the median). Lastly, potential avenues for improving our field will be offered based on the findings, ranging from low-effort yet somehow controversial improvements, to high-effort foundational considerations. T2 - International Small-Angle Scattering Conference (SAS2022) CY - Campinas, Brazil DA - 11.09.2022 KW - Round robin KW - Data analysis KW - Small angle scattering KW - Nanomaterials KW - MOUSE KW - Interlaboratory comparison KW - Intercomparability KW - Reliability KW - Data analysis round robin KW - Large number of participants PY - 2022 AN - OPUS4-55762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogel, Christian A1 - Roesch, Philipp T1 - Analytical Challenges for PFAS in Environmental Samples - Methods, Approaches and Applicability N2 - Per- and polyfluoroalkyl substances (PFAS) are anionic, cationic and zwitterionic synthetic products, in which the hydrogen atoms on the carbon skeleton of at least one carbon atom have been completely replaced by fluorine atoms and which include up to 1.7 M compounds, depending on the definition. As a result of continuous and prolific use, mainly in aviation firefighting foams, thousands of industrial and military installations have been found to contain contaminated soil, groundwater and surface water. Furthermore, because of the continuous contamination through PFAS containing commercial products, effluents and sewage sludge from WWTPs have been shown to be an important source of PFAS discharge into the aquatic environment. In the last few years, legacy PFAS (≥C4) have been found in various environments, including soil, water and wastewater, and their environmental pathways have been partly described. Several long-chain PFAS species, and their respective salts are considered as persistent organic pollutants by the United Nations Stockholm Convention. These pollutants have been linked to altered immune and thyroid function, liver disease, lipid and insulin dysregulation, kidney disease, adverse reproductive and developmental outcomes, and cancer. A significant shift in the chemical industry towards production of short (C4-C7) and ultrashort (C1-C3) alternatives was observed in response to recently intensified regulations and restrictions on the use of long-chain (≥C8) PFAS. PFAS analysis in environmental samples is currently mainly done by liquid chromatography tandem mass spectrometry (LC-MS/MS). This efficient method is conducted in a targeted fashion analyzing a small subset of PFAS. The US EPA method for analysis of PFAS using LC-MS/MS for example currently lists 40 PFAS (≥C4). However, to get a better overview of the amount of “total PFAS,” sum parameter methods like total oxidizable precursor (TOP) assay and methods based on combustion ion chromatography (CIC) are in development. CIC results in data regarding the sum of absorbable organic fluorine (AOF) or extractable organic fluorine (EOF), which can also quantify other organically bound fluorine compounds such as fluorinated pesticides and pharmaceutical. Moreover, non-target and suspect screening mass spectrometry can be used to identify novel emerging PFAS and partly unknown fluorinated compounds in environmental samples. Furthermore, to analyze ultrashort PFAS (C1-C3), supercritical fluid chromatography (SFC), hydrophilic interaction chromatography (HILIC) and gas chromatography-mass spectrometry (GC-MS) are available, but further research is needed to develop reliable and accurate methods to quantify several ultrashort PFAS in environmental samples. Additionally, for research purpose several spectroscopical methods like X-ray photoelectron spectroscopy (XPS), fluorine K-edge X-ray absorption near-edge structure (XANES)spectroscopy, particular induced gamma-ray emission (PIGE) spectroscopy and 19F nuclear magnetic resonance (NMR) spectroscopy are available. T2 - CleanUp 2022 CY - Adelaide, Australia DA - 11.09.2022 KW - PFAS KW - Combustion ion chromatography KW - XANES spectroscopy PY - 2022 AN - OPUS4-55741 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogel, Christian A1 - Roesch, Philipp A1 - Wittwer, Philipp T1 - PFAS Sum Parameter and Structural Analysis N2 - Per- and polyfluoroalkyl substances (PFAS) are anionic, cationic and zwitterionic synthetic products, in which the hydrogen atoms on the carbon skeleton of at least one carbon atom have been completely replaced by fluorine atoms (see Figure 1) and which include more than 4730 compounds, depending on the definition. As a result of continuous and prolific use, mainly in aviation firefighting foams, thousands of industrial and military installations have been found to contain contaminated soil, groundwater and surface water. Furthermore, because of the continuous contamination through PFAS containing commercial products, effluents and sewage sludge from WWTPs have been shown to be an important source of PFAS discharge into the aquatic environment. In the last few years, legacy PFAS (≥C4) have been found in various environments, including soil, water and wastewater, and their environmental pathways have been partly described. To get a better overview of the amount of “total PFAS,” sum parameter methods like total oxidizable precursor (TOP) assay and methods based on combustion ion chromatography (CIC) are in development. CIC results in data regarding the sum of absorbable organic fluorine (AOF) or extractable organic fluorine (EOF), which can also quantify other organically bound fluorine compounds such as fluorinated pesticides and pharmaceutical. Additionally, for research purpose several spectroscopical methods like X-ray photoelectron spectroscopy (XPS), fluorine K-edge X-ray absorption near-edge structure (XANES) spectroscopy, particular induced gamma-ray emission (PIGE) spectroscopy and 19F nuclear magnetic resonance (NMR) spectroscopy are available. Therefore, an overview is given on various analytical techniques for PFAS in environmental samples and their application possibilities discussed for different kind of PFAS compounds T2 - CleanUp 2022 CY - Adelaide, Australia DA - 11.09.2022 KW - PFAS KW - Combustion ion chromatography KW - XANES spectroscopy KW - Soil PY - 2022 AN - OPUS4-55743 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob T1 - X-ray scattering for nanostructure quantification, and the quest for the perfect experiment N2 - Measuring an X-ray scattering pattern is relatively easy, but measuring a steady stream of high-quality, useful patterns requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). With the MOUSE, we have combined a comprehensive and highly automated laboratory workflow with a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. This talk will briefly introduce the foundations of X-ray scattering, present the MOUSE project, and will highlight the proven utility of the methodology for materials science. Upgrades to the methodology will also be discussed, as well as possible avenues for transferring this holistic methodology to other instruments T2 - SNI 2022 CY - Berlin, Germany DA - 05.09.2022 KW - Methodology KW - X-ray scattering KW - Laboratory management KW - Instrumentation utilization KW - MOUSE KW - SAXS KW - WAXS KW - Automation PY - 2022 AN - OPUS4-55760 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klewe, Tim A1 - Kruschwitz, Sabine A1 - Wöstmann, Jens T1 - Overview of NDT techniques for moisture measurements in building materials N2 - Overview of NDT techniques for moisture measurements in building materials used in department 8 of BAM. T2 - ENBRI Expert Workshop "Hygrothermal testing - a necessity to guarantee durable buildings" CY - Brussels, Belgium DA - 21.09.2022 KW - Moisture KW - Building materials KW - GPR KW - NMR KW - Microwave PY - 2022 AN - OPUS4-55817 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Holstein, Tanja A1 - Kistner, Franziska A1 - Martens, L. A1 - Muth, Thilo T1 - PepGM: A graphical model for taxonomic profiling of viral proteomes N2 - In mass spectrometry based proteomics, protein homology leads to many shared peptides within and between species. This complicates taxonomic inference. inference. We introduce PepGM, a graphical model for taxonomic profiling of viral proteomes and metaproteomic datasets. Using the graphical model, our approach computes statistically sound scores for taxa based on peptide scores from a previous database search, eliminating the need for commonly used heuristics. heuristics. T2 - European proteomics association conference 2022 CY - Leipzig, Germany DA - 03.04.2022 KW - graphical models KW - Taxonomic inference KW - Bioinformatics KW - Virus protoemics PY - 2022 AN - OPUS4-56750 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Simon, Fabian A1 - Faßbender, Sebastian A1 - Meermann, Björn T1 - Mercury speciation in sediments of industrially impacted water bodies in Northern Germany using SSID GC/ICP-ToF-MS N2 - Sediments and soils can act as sinks of species of inorganic mercury (Hg2+), while they are simultaneously sources of organic species, such as monomethylmercury (MMHg). Although the fraction of MMHg in total Hg of sediments is suggested to be only 0.1–1%, MMHg poses a threat for humans and wildlife due to its toxic properties, high bioaccumulation potential and the ability to pass the blood-brain barrier. One example of a highly Hg contaminated waterbody is the Finow Canal, the oldest artificial waterway still in operation in Germany. Here, Hg mass fractions of up to 100 µg/g were found in the sediment in previous studies. These are suggested to be associated with a chemical plant producing mercury-based seed dressings. Despite this high mass fraction of Hg, no Hg speciation studies have been conducted there up to now. In this study, Hg speciation in sediments of Finow Canal at locations before and after the known polluted site was conducted using species-specific isotope dilution (SSID) GC-ICP-ToF-MS. Mass fractions of up to 0.41 µg/g MMHg were determined. In addition, waterbodies around the initially polluted site were investigated and elevated concentrations were also determined around 14 km downstream. For MMHg analysis, the performance of ICP-ToF-MS for SSID GC/ICP-MS was compared with ICP-Q-MS and ICP-SF-MS. Here, isotope ratio precision was similar between the tested instruments. However, the (quasi-) simultaneous detection of the whole mass spectrum will probably offer a much higher precision of ICP-ToF-MS, when more than one isotope system is used. These results are the first evidence of the occurrence of MMHg in this region and show the need for further investigations of the whole regional ecosystem, as well as the consideration of possible measures of remediation. SSID GC-ICP-(ToF)-MS is a suitable tool for investigating species-specific (multi) isotope systems for environmental monitoring. T2 - 33. Doktorandenseminar des AK Separation Science CY - Hohenroda, Germany DA - 08.01.2023 KW - Mercury KW - GC/ICP-ToF-MS KW - Isotope dilution PY - 2023 AN - OPUS4-56816 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Holstein, Tanja A1 - Kistner, Franziska A1 - Martens, L. A1 - Muth, Thilo T1 - PepGM: A graphical model for taxonomic profiling of viral proteomes N2 - In mass spectrometry based proteomics, protein homology leads to many shared peptides within and between species. This complicates taxonomic inference. inference. We introduce PepGM, a graphical model for taxonomic profiling of viral proteomes and metaproteomic datasets. Using the graphical model, our approach computes statistically sound scores for taxa based on peptide scores from a previous database search, eliminating the need for commonly used heuristics. T2 - European bioinformatics community winter school 2022 CY - Lisbon, Portugal DA - 21.03.2022 KW - Bioinformatics KW - Virus protoemics KW - Taxonomic analysis KW - Graphical models PY - 2022 AN - OPUS4-56753 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Griepentrog, Michael A1 - Hertwig, Andreas A1 - Weise, Matthias T1 - White light interference microscopy, ellipsometry, and instrumented indentation testing as reference procedures N2 - The paper addresses “WHITE LIGHT INTERFERENCE MICROSCOPY, ELLIPSOMETRY, AND INSTRUMENTED INDENTATION TESTING AS REFERENCE PROCEDURES“ and is subdivided in the following sections: 1. Measurement vs. testing vs. reference procedures, 2. White light interference microscopy (WLIM) for determination of step height h, 3. Spectroscopic ellipsometry (SE) for determination of layer thickness d and 4. Instrumented indentation testing (IIT) for determination of indentation hardness HIT. The following points are discussed in more detail: methodology of measurement and testing, uncertainty budgets for direct (WLIM), model-based (SE) and formula-based (IIT) reference procedures by means of specific examples. It is shown that standardization efforts are connected to reference procedures. T2 - Referenzverfahren CY - BAM, Berlin, Germany DA - 21.02.2018 KW - Reference procedures KW - Uncertainty budgets KW - White light interference microscopy KW - Spectroscopic ellipsometry KW - Instrumented indentation testing PY - 2018 AN - OPUS4-44256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Wegmann, Marc A1 - Hannemann, M. A1 - Somma, V. A1 - Jochum, T. A1 - Niehaus, J. A1 - Roggenbuck, D. T1 - Automated determination of genotoxicity of nanoparticles with DNA-based optical assays - The NANOGENOTOX project N2 - The overall interest in nanotoxicity, triggered by the increasing use of nanomaterials in the material and life sciences, and the synthesis of an ever increasing number of new functional nanoparticles calls for standardized test procedures1,2 and for efficient approaches to screen the potential genotoxicity of these materials. Aiming at the development of fast and easy to use, automated microscopic methods for the determination of the genotoxicity of different types of nanoparticles, we assess the potential of the fluorometric γH2AX assay for this purpose. This assay, which can be run on an automated microscopic detection system, relies on the detection of DNA double strand breaks as a sign for genotoxicity3. Here, we provide first results obtained with broadly used nanomaterials like CdSe/CdS and InP/ZnS quantum dots as well as iron oxide, gold, and polymer particles of different surface chemistry with previously tested colloidal stability and different cell lines like Hep-2 and 8E11 cells, which reveal a dependence of the genotoxicity on the chemical composition as well as the surface chemistry of these nanomaterials. These studies will be also used to establish nanomaterials as positive and negative genotoxicity controls or standards for assay performance validation for users of this fluorometric genotoxicity assay. In the future, after proper validation, this microscopic platform technology will be expanded to other typical toxicity assays. T2 - SPIE 2018 CY - San Francisco, USA DA - 27.01.2018 KW - Nanoparticle KW - Fluorescence KW - Surface chemistry KW - Size KW - Assay KW - Microscopy KW - Nanotoxicity KW - Toxicity KW - Automation KW - Calibration KW - Standard PY - 2018 AN - OPUS4-44186 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Hertwig, Andreas A1 - Winkler, J. T1 - Preliminary work item (PWI) 23131 on standardization of ellipsometry N2 - The paper addresses the PRELIMINARY WORK ITEM (PWI) 23131 ON STANDARDIZATION OF ELLIPSOMETRY and the following points are discussed in more detail: Historical background of ellipsometry, Technical/industrial importance of ellipsometry and Standardization activities on ellipsometry. T2 - ISO TC 107 and JWG 4 meeting CY - Levi, Finland DA - 23.01.2018 KW - Standardization KW - Ellipsometrie KW - Modelling KW - Accreditation PY - 2018 AN - OPUS4-43959 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Taparli, Ugur Alp A1 - Griesche, Axel A1 - Kannengießer, Thomas A1 - Jacobsen, Lars A1 - Michalik, Katarzyna A1 - Mory, David T1 - In situ laser-induced breakdown spectroscopy measurements in stainless steels during TIG welding N2 - Chemical composition of the welding seam and HAZ has significant effect on weld quality. Current inspection methods for weld seams measure and investigate post factum and cannot prevent weld defects. Element burn-off may significantly affect solidification leading to embrittlement or cracking Control of weld chemical compositions insures a controlled solidification and resistance to related weld defects. A prototype of a LIBS controlled welding process is presented. T2 - Forschungsseminar Universität Magdeburg CY - Magdeburg, Germany DA - 17.01.2018 KW - LIBS KW - TIG-Welding KW - Chemical compositions KW - In situ measurements PY - 2018 AN - OPUS4-43830 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Characterization of co (polyamide)s N2 - Charactrization of Co(polyamide)s Molar mass distribution; Functionalization; supression of end group effects in favor of sequence distribution analysis; Evidence of of randomization with increasing reaction time T2 - Polyamide Meeting, DSM CY - Sittard, The Netherlands DA - 20.04.2018 KW - Liquid chromatography KW - Mass spectrometry of polymers PY - 2018 AN - OPUS4-44747 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weidner, Steffen A1 - Kricheldorf, H. A1 - Scheliga, F. T1 - Cyclic polylactides via ring-expansion polymerization N2 - We will report on a new kind of ring-expansion polymerization (REP) of cyclic esters based of three classes of catalysts. In contrast to REP described previously these new polymerizations are characterized by a self-extrusion of the catalysts resulting in cyclic homopolyesters as the only reaction product. These REP of L-lactide were performed in bulk at temperatures between 100 and 180°C without racemization. A simplified scheme of a REP catalyzed by BuCa or SnBi is presented below. With meso-lactide temperatures down to 60°C were realized. Depending on catalyst, time and temperature with equal quantities of even and odd-numbered cycles a strong predominance of either even or odd-numbered cycles was found. T2 - 255th ACS National Meeting CY - New Orleans, LA, USA DA - 18.03.2018 KW - MALDI-TOF MS KW - Poly(lactide) KW - Polymerisation KW - Catalysts PY - 2018 AN - OPUS4-44833 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Lessons on measurement of nanoparticle size and shape learnt from NanoDefine N2 - The EC Recommendation on the definition of nanomaterial1, based solely on size of the constituent particles, foresees development of harmonised measurement methods ensuring ‘consistent results across materials and over time’. The EU/FP7 large research project NanoDefine (http://www.nanodefine.eu) has been exclusively dedicated to support the implementation of this EC Recommendation for the European Union’s legislation. For the first time, measurement techniques able to determine the size of nanoparticles have been evaluated systematically on a well-defined set of quality control materials (spherical, monodisperse) as well as industrial materials of complex shapes and considerable polydispersity. Particularly based on the analytical performance of the measurement techniques as tested on the challenging real-world particulate materials, it was possible to formulate recommendations for use of a new tiered approach consisting of screening and confirmatory techniques. Thus, a consistent framework of guidance for nanomaterial identification according to the EC Definition has been issued in form of the NanoDefiner e-tool (https://labs.inf.fh-dortmund.de/NanoDefiner), with a transparent decision flow scheme and an extensive user manual. Selected examples of analysis and classification as nano-/non-nanomaterials will be given, highlighting the limits of applicability of the available measurement techniques in dependence on sample properties. On some recent relevant developments in sample preparation – as a crucial part for an accurate analysis - will be also reported. T2 - RSC-NPL Symposium: Nanoparticle concentration – critical needs and state-of-the-art measurement CY - London, UK DA - 24.04.2018 KW - Nanoparticles KW - Nanomaterial KW - Particle size distribution KW - EU definition of nanomaterial PY - 2018 AN - OPUS4-44804 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Makowski, Maike A1 - Jung, Christian A1 - Werneburg, Martina A1 - Haase, H. A1 - Koch, Matthias T1 - Non-invasive Cereal Analysis by GC-MS detection of Trichodiene as a Volatile Mycotoxin Biomarker N2 - Due to the increasing consumption of cereals worldwide, the monitoring of growth, storage and processing is becoming more and more crucial. Particularly when stored, infested grains breed fungal clusters (“hot spots”) in which mycotoxins greatly exceed allowed maximum levels. Because of their unpredictable presence, current sample drawing and procedures for mycotoxin analysis represent a complex challenge for operators, involving invasive and cost intensive steps. Therefore, new time- and labour-saving mycotoxin control methods including sampling and analysis steps are needed. A possible approach is the non-invasive analysis of the homogeneous gas phase above the crops, instead of analyzing random samples. However, this procedure requires microbial volatile organic compounds (MVOC´s) being released by the samples and representing the present mycotoxins. Previous investigations revealed trichodiene to be a precursor in trichothecenes biosynthesis – one of the largest mycotoxin groups with over 180 compounds. Due to its non-functionalized sesquiterpene structure, trichodiene has already been quantified using Headspace GC-MS methods (for instance). Thereby, it can possibly be used as a biomarker for trichothecene contamination in foodstuff. However, further investigations are necessary. The correlation between trichodiene concentration in the gas phase and trichothecenes mass fraction in the sample must be examined closely to draw conclusions about the exact trichothecene content within samples. Realizing this idea, would widely extend the applicability of trichodiene and enormously simplify trichothecene quantification. Hence, this first step of an ongoing study aims to develop a laboratory reference method using trichodiene as volatile biomarker to quantify trichothecenes in cereals. Static headspace and SPME-enrichment coupled to gas chromatography with mass spectrometry (GC-MS) were employed. In a second step, this reference method is intended to validate new approaches for fast on-site screening of trichodiene in cereals. T2 - 10th World Mycotoxin Forum Conference CY - Amsterdam, The Netherlands DA - 11.03.2018 KW - Trichodiene KW - GC-MS KW - Mycotoxin Biomarker PY - 2018 AN - OPUS4-44509 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Plasma Fundamentals and Diagnostics N2 - This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, microreactions, pump and probe diagnostics, tomography, temporal and spatial resolution. Basis of plasma computer modeling will be presented. T2 - Winter Plasma Conference CY - Amelia Island, FL, USA DA - 08.01.2018 KW - Plasma diagnostics KW - Plasma physics PY - 2018 AN - OPUS4-44497 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. A1 - Shabanov, Sergej V. T1 - Modeling chemical reactions in laser-induced plasmas at local thermodynamic equilibrium N2 - Laser induced plasma (LIP) is a dynamic, short living event which presents significant difficulty for modeling. In this report, a collisional-dominated chemical model developed earlier* is expanded by the inclusion of a new method for calculation of chemical reactions. The model consists of the coupled Navier-Stokes, state, radiative transfer, material transport, and chemical equations. The latter are written in terms of atomic and molecular partition functions rather than reaction rates. Typically, a solution of such the system of chemical equations is difficult for the entire range of plasma temperatures and densities because reaction constants may vary by hundreds orders of magnitude owing to extreme plasma conditions. No numerical solver of non-linear systems of equations handles this situation with ease. We resolve the problem by using a hierarchical approach. First, we rank the reactions according to their ascendancy. Second, we exploit either the contraction or Newton-Raphson algorithms to solve the system of chemical equations. We illustrate the approach by performing a series of calculations for reacting species Si, C, N, Ca, Cl and their molecules in laser induced plasmas. T2 - Winter Plasma Conference CY - Amelia Island, FL, USA DA - 08.01.2018 KW - Plasma physics KW - Plasma diagnostics PY - 2018 AN - OPUS4-44499 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kjaervik, Marit A1 - Schwibbert, Karin A1 - Dietrich, P. A1 - Thissen, A. A1 - Unger, Wolfgang T1 - Surface characterisation of bacteria and biofilms by NAP-XPS N2 - The XPS information depth of approximately 10 nm is in the same size range as the outer membrane of the gram-negative bacteria, which makes XPS a suitable tool for determining the elemental composition of the bacterial surface and monitor changes caused by outer stress like dehydration or exposure to antimicrobials. However, bacteria are inherently in a hydrated state, and therefore only compatible to ultra-high vacuum after extensive sample preparation, which may degrade the sample constituents. This issue is addressed by the development of near-ambient pressure (NAP)-XPS, which enables bacteria and biofilms to be characterised in their native wet state. Artificial biofilms, bacteria and biofilms of Escherichia coli have been characterised with the laboratory NAP-XPS instrument EnviroESCA from SPECS GmbH, at pressures ranging from high vacuum to 12 mbar, and in both humid and dry environment. By studying biological samples in their native wet state, new insight about composition and transport of drugs through cell membranes and the extracellular polymeric substance (EPS) of biofilms can be obtained. In this contribution, the latest progress on biofilm characterisation by NAP-XPS will be presented, and measurement capabilities and limitations will be discussed. T2 - Die Frühjahrstagung der Deutsche Physikalische Gesellschaft CY - Berlin, Germany DA - 12.03.2018 KW - Biofilms KW - E. coli KW - Alginate KW - NAP-XPS PY - 2018 AN - OPUS4-44500 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Ultrasound: From Imaging to Monitoring N2 - Review of ultrasonic echo imaging and ultrasonic monitoring techniques applied to concrete structures, especially bridges. Includes newest research results from BAM. T2 - Transport Research Board Annual Meeting, Workshop 1647 CY - Washington, DC, USA DA - 6.1.2018 KW - Ultrasound KW - Imaging KW - Monitoring KW - Concrete KW - Bridges PY - 2018 AN - OPUS4-44587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Fischer, Daniel A1 - Hertwig, Andreas A1 - Hidde, Gundula A1 - Stockmann, Jörg M. A1 - Weise, Matthias T1 - Ellipsometric imaging of low-contrast surface modifications and depolarization contrast imaging (DCI) of particulate accumulations N2 - Imaging of surfaces regarding topographical, morphological, micro-structural, and chemical features is a key requirement for quality control for the identification of contaminated, degraded, damaged or deliberately modified surface areas vs. clean, virgin, undamaged or unmodified regions. As optical functions may represent any of these changes on the micro- and nano-scale, imaging ellipsometry (IE) is the technique of choice using either intensity, phase, or/and amplitude contrast for visualization of low-contrast surface modifications [1, 2]. Defects or surface and film features whether native or artificial, intended or unintended, avoidable or unavoidable as well as surface pattern are of interest for quality control. In contrast to microscopic techniques operated at normal incidence, ellipsometry as oblique-incidence technique provides improved contrast for vertically nano-scaled add-on or sub-off features such as ultra-thin transparent films, metallic island films, carbon-based thin films, laser modification or laser induced damage, dried stain, cleaning agent or polymeric residue. Two-sample reference techniques, i.e. referenced spectroscopic ellipsometry (RSE) may further increase sensitivity and decrease measurement time. In case of particulate accumulations depolarization contrast imaging (DCI) may improve the lateral resolution beyond the Abbe limit. This has been proven for silica spheres as reference in terms of single particles, particulate accumulations or particulate monolayers and layer stacks. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used for reference measurements of particle diameter, particle height, or particulate layer/accumulation thickness. It has been shown that single silica particles of 250 nm in diameter, i.e. at least a factor of 4 better than the lateral resolution limit as of now, can be visualized on even substrates. However, the ellipsometric measurement of particle diameters of this size needs further efforts interpretation. T2 - Workshop Ellipsometry 2018 CY - Chemnitz, Germaný DA - 19.03.2018 KW - Low-contrast surface modifications KW - Particulate distributions KW - Imaging ellipsometry(IE) KW - Depolarization contrast imaging (DCI) PY - 2018 AN - OPUS4-44548 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Improved algorithm for calibration-free laser induced breakdown spectroscopy N2 - An improved algorithm for calibration-free laser induced breakdown spectroscopy (CF LIBS) is presented which includes several novel features in comparison with previously proposed similar algorithms. In particular, it allows using spectral lines with arbitrary optical thickness for the construction of Saha-Boltzmann plots, retrieves the absorption path length (plasma diameter) directly from a spectrum, replaces the Lorentzian line profile function by the Voigt function, and allows for self-absorption correction using pre-calculated and tabulated data rather than approximating functions. The tabulated data embody the solutions of the radiative transfer equation for numerous combinations of optical thicknesses and line widths. The algorithm is thoroughly verified with synthetic spectra. T2 - 14TH European Workshop on Laser Ablation 2018 (EWLA2018) CY - Pau, France DA - June 26 - 29, 2018 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics KW - Calibration free LIBS PY - 2018 AN - OPUS4-45343 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Laser induced plasma: Modeling, diagnostics, and applications N2 - Laser-induced plasmas are widely used in many areas of science and technology; examples include spectrochemical analysis, thin film deposition, material processing, and even jet propulsion. Several topics will be addressed. First, general phenomenology of laser-induced plasmas will be discussed. Then, a chemical model will be presented based on a coupled solution of Navier-Stokes, state, radiative transfer, material transport, and chemical (Guldberg-Waage) equations. Results of computer simulations for several chemical systems will be shown and compared to experimental observations obtained by optical imaging, spectroscopy, and tomography. The latter diagnostic tools will also be briefly discussed. Finally, a prospective application of laser-induced plasma and plasma modeling will be illustrated on the example of calibration-free MC LIBS (Monte Carlo Laser Induced Breakdown Spectroscopy), in which concentrations of elements in materials are found by fitting model-generated and experimental spectra. T2 - Invited talk at Yeshiva University, New York, USA CY - Yeshiva University, New York, USA DA - 4.24.2018 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2018 AN - OPUS4-45344 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kjaervik, Marit A1 - Dietrich, P. A1 - Thissen, A. A1 - Schwibbert, Karin A1 - Unger, Wolfgang T1 - Quantitative biocide profile measurements by calibrated NAP-XPS N2 - Progress update for the EMPIR-project MetVBadBugs- Quantitative measurement and imaging of drug-uptake by bacteria with antimicrobial resistance. T2 - MetVBadBugs 26 M project meeting CY - South Mimms, UK DA - 05.07.2018 KW - Biofilms KW - Alginate KW - Antibiotics KW - E. coli KW - XPS PY - 2018 AN - OPUS4-45402 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Yildirim, Arda T1 - Liquid Crystals Forming a Columnar Mesophase: Structure, Dynamics and Electric Conductivity N2 - The molecular dynamics and ionic conductivity of ionic liquid crystals (ILCs) forming a columnar mesophase, two linear-shaped tetramethylated guanidinium triflates ILCs having different lengths of alkyl chains, were investigated by a combination of Broadband Dielectric Spectroscopy (BDS) and Specific Heat Spectroscopy (SHS). Three processes were detected by BDS; at low temperature γ-process, at higher temperatures α-process and at even higher temperatures conductivity. The γ-process indicates localized fluctuations, and the α-process designates cooperative fluctuations. Slightly different restrictions were found for conductivity processes of LC536 and LC537 due to the slightly different lengths of alky chains. The conductivity mechanisms in the plastic crystalline and the columnar mesophase have been revealed by BDS and different charge carriers were assigned for the different phases. Furthermore, the cooperative dynamics were also probed by SHS. The cooperative dynamics probed by the different techniques (BDS and SHS) compared, and assigned to the different restrictions on the cooperativity due to the difference in the sensitivity of the techniques. T2 - Seminar Vortrag Technische Universität Berlin CY - Berlin, Germany DA - 28.06.2018 KW - Columnar Liquid Crystals KW - Ionic Liquid Crystals PY - 2018 AN - OPUS4-45383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Metz, Christian A1 - Franz, Philipp A1 - Maierhofer, Christiane A1 - Wachtendorf, Volker A1 - Fischer, C. T1 - Active thermography for quality assurance of 3D-printed polymer structures N2 - Active thermography with flash and halogen light excitation is used as a method for non-destructive testing of 3D-printed polymer components. Test specimens with artificial defects have been generated, using laser sintering and fused layer modeling. These test specimens have been investigated in different measurement configurations with both excitation methods. Afterwards, the different measurement conditions were compared regarding their capability to detect the defects. Furthermore, advanced analysis methods are used, to fully exploit the capabilities of these techniques. T2 - 14th Quantitative InfraRed Thermography Conference CY - Berlin, Germany DA - 25.06.2018 KW - Additive manufacturing KW - Active thermography KW - Artificial weathering PY - 2018 AN - OPUS4-45387 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nutsch, A. A1 - Dill, S. A1 - Kamleitner, I. A1 - Sehorz, A. A1 - Schwarzenberger, M. A1 - Streeck, C. A1 - Beckhoff, B. A1 - Merz, H. A1 - Recknagel, Sebastian T1 - A Methodology to Obtain Traceability and Validation of Calibration Samples for Thin Metal Alloy Layers for X-Ray Fluorescence Tools N2 - Statistic process control as well as process capability demand for calibrated determination of layer thicknesses in various industries, e.g. automotive, aerospace, microelectronics manufacturing. Calibration requires well know and well characterized samples. A calibration laboratory accredited according to DIN EN ISO 17025 has the objective to distribute standards traceable to SI units to industrial laboratories for quality control of manufacturing of various products. Especially, the thickness determination of thin metallic coatings e.g. from galvanic processes or layer deposition using X-Ray Fluorescence can be significantly improved by customized calibration samples. This is essential as the measurement uncertainty directly correlates to the capability performing reliable control of processes with high yield. For calibration laboratories, the validation of results using round robins and the direct comparison to national metrology institutes is a prerequisite to demonstrate the competence to perform calibration services. In this paper a strategy to obtain traceability and validation for thin alloy layers as well as first results are presented. The combined use of the accredited method for determination of mass per area from measurement of mass and area combined with standard free X-Ray Fluorescence as well as chemical analysis of dissolved samples with thin layers is deployed for material systems as NixZn1-x as well as NixP1-x. The obtained results are compared to reference free X-Ray Fluorescence at the BESSY II laboratories of Physikalisch-Technische Bundesanstalt. An excellent agreement of the obtained measured values as mass per unit area and alloy concentrations from the different applied methods within the measurement uncertainty was observed for NixP1-x showing the successful performed traceability of the calibration samples to SI units in combination with a validation of results by national metrology institutes and the round robin approach. T2 - European Conference on X-Ray Spectrometry CY - Ljubljana, Slowenia DA - 24.06.2018 KW - Traceability KW - Thin metal alloy layers KW - X-ray fluorescence PY - 2018 AN - OPUS4-45317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Kotschate, Daniel T1 - New technologies for air-coupled ultrasonic transducers N2 - Air-coupled ultrasonic testing (ACUT) has experienced rapid growth within the last years. It is especially well suited to inspection of lightweight structures consisting of composite materials and adhesive joints. Uniform coupling and easy maintenance are its advantages compared to contact technique. However, the impedance mismatch between the transducer and air poses a major challenge to the development of ACUT transducers. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers. Their fabrication is difficult in handling and their signal-to-noise ratio sometimes not sufficient for various testing requirements. However, there are several innovative approaches using other materials and other physical principles to transmit and receive an ultrasonic pulse. We present a review of the latest advances in research on air-coupled transducers for non-destructive testing, including previously unpublished results. We recognize two major directions as most promising: ferroelectrets and thermoacoustic transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties. Their small acoustic impedance is matched to air better than matching layers applied in conventional air-coupled transducers. Applying bias voltage to a ferroelectret receiver is the latest development in this field, which increased the received signal by 12 to 15 dB. Thermoacoustic transducers use heat to initiate an ultrasonic wave, acting as transmitters. The working principle is known from nature as thunder and lightning: thermal energy of an electrically heated material, which can also be air, is converted into acoustic energy. Some thermoacoustic transmitters consist of a conductive layer with a thickness in the nanometer range deposited on a solid substrate. Another possibility is to use an electric spark. For the first time, measurements of the sound field of an electric spark up to 500 kHz were performed. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. T2 - 12th European conference on Non-Destructive Testing CY - Gothenburg, Sweden DA - 11.06.2018 KW - Transducer KW - Air-coupled ultrasonic testing KW - Atmospheric pressure plasma KW - Cellular polypropylene KW - Ferroelectret PY - 2018 AN - OPUS4-45304 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Strangfeld, Christoph T1 - Moisture testing and mapping N2 - Non-destructive testing of moisture in building materials T2 - NDT&E Advanced Training Workshop CY - Berlin, Germany DA - 27.06.2018 KW - Building materials KW - Concrete KW - Moisture measurement PY - 2018 AN - OPUS4-45348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Buildings: Seismology and Strctural Health Monitoring N2 - Overview of seismological concepts unsed in nondestructive testing in civil engineering T2 - Fourth TIDES Advanced Training School CY - Prague, Czech Repubilc DA - 01.07.2018 KW - Geophysics KW - Seismology KW - Interferometry KW - Structural health monitoring KW - Nondestructive testing PY - 2018 AN - OPUS4-45361 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bonnerot, Olivier A1 - Bosch, S. A1 - Rabin, Ira A1 - Hahn, Oliver T1 - Scientific service project Z02 at the CSMC: Material-science methods of reconstructing the history of manuscripts N2 - Z02 is one of the three technically supporting projects at the CSMC. In collaboration with Z01 and Z03, it aims at bridging the gap between humanities and natural sciences and technology. To that purpose, we set up a laboratory with a range of high-end instruments, most of them mobile, allowing thorough non-destructive analysis of manuscripts. In addition to working on constantly improving the laboratory and the methods of analysis, a substantial part of our activities is dedicated to service, by supporting different research projects conducted at the center. In this talk, we will present our equipment and the possibilities offered by the different techniques available regarding the different kinds of missions: typology and classification of inks, provenance studies, recovery of faded inscriptions and palimpsests, reconstruction of the history of manuscripts, authentication and dating. We will give a brief overview of our past and ongoing activities in the frame of the second phase of the CSMC. Finally, a selection of three projects will be presented in greater detail to highlight the possibilities of our laboratory and the diversity of missions which can be carried out: - Support of project C08 on East Frankish manuscripts containing collections of formulae - Identifying color materials applied in Muhammad Juki's Shahnamah with non-invasive combined methods - Checking for the presence of metals in the Herculaneum papyri T2 - 3rd International Conference on Natural Sciences and Technology in Manuscript Analysis CY - Hamburg, Germany DA - 13.06.2018 KW - CSMC KW - Manuscript KW - Ink KW - Pigment PY - 2018 AN - OPUS4-45504 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kjaervik, Marit A1 - Dietrich, P. A1 - Thissen, A. A1 - Schwibbert, Karin T1 - Surface characterisation of biological samples by near-ambient pressure XPS N2 - A presentation held for the seminar "Ausgewählte analytische Methoden der Physik" hosted by Prof. Birgit Kanngießer at TU Berlin. The first part focus on depth-dependent XPS-measurements (XPS, synchrotron HAXPES) to obtain a concentration profile of iodine in an artificial biofilm. In the second part, NAP-XPS measurements of various bacterial samples are presented. T2 - Forschungsseminar "Ausgewählte analytische Methoden der Physik", TU Berlin CY - Berlin, Germany DA - 17.07.2018 KW - Biofilms KW - Alginate KW - Agarose KW - HAXPES KW - NAP-XPS PY - 2018 AN - OPUS4-45505 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Wuerth, Christian A1 - Kraft, Marco A1 - Kaiser, Martin A1 - Radunz, Sebastian A1 - Muhr, V. A1 - Hirsch, Th. A1 - Soukka, T. A1 - Homann, C. A1 - Haase, M. T1 - Luminescence efficiency of upconversion – Quantification of size, particle architecture and dopant concentration effects for different excitation power densities N2 - Lanthanide-based upconversion nanoparticles (UCNPs)like hexagonal beta-NaYF4 UCNPs doped with Yb3+ and Er3+, which efficiently convert 976 nm light to ultraviolet, visible, and near infrared photons, offer new strategies for luminescence-based sensing and imaging. The properties of their upconversion (UC) luminescence (UCL) are, however, strongly influenced by particle size, concentration and spatial arrangement of dopant ions, surface chemistry, microenvironment, and excitation power density (P). We present here comprehensive studies of the influence of UCNP size and particle architecture for Yb3+ and Er3+ co-doped NaYF4 nanoparticles and energy transfer processes in these materials, which underline the importance of quantitative luminescence measurements for mechanistic insights and the determination of application-relevant matrix- and P-dependent optimum dopand concentrations. T2 - 2nd Conference and Spring School CY - Valencia, Spain DA - 04.04.2018 KW - Upconverting nanoparticles KW - Size KW - Energy transfer KW - Fluorescence KW - Absolute fluorescence quantum yield KW - Fluorescence decay kinetics KW - Power density dependence PY - 2018 AN - OPUS4-44960 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Baier, Jennifa A1 - Hidde, Gundula A1 - Sahre, Marion A1 - Weise, Matthias T1 - Particles in PVD-coatings: Imperfection or functional add-on feature? N2 - The application of PVD-coatings ranges from mechanical engineering, i.e. thicker tribological coatings, to precision optics, i.e. thinner optical coatings. For physical vapor deposition (PVD) technologies such as evaporation, sputtering, ion beam assisted/driven deposition, vacuum is a prerequisite for two reasons: at first process-related ones (evaporation source, plasma discharge, and mean free path) and at second coating-related ones (pure, perfect, and dense films). Usually, the goal is a homogenous coating of defined stoichiometry and micro-structure without any imperfection. However, the implementation of micro- or nano-particles may occur accidentally or delibe-rately. Independent of the particle origin, there are two fundamental rules regarding coating functionality: at first, the larger the particle diameter to coating thickness ratio the more affected the functionality of the coating, and at second, the larger the material contrast in terms of the functional feature of interest the more affected the coating performance. Hence, embedded particles have to be avoided for the majority of thin films by all means. The unintended implementation of particles usually results in a malfunction of the coating from the beginning or is at least considered as a weak point of the coating creating a time-dependent defect under service conditions. The intended implementation of particles on surfaces and in coatings may create add-on features, topographic ones and functional ones, however, the facts mentioned hold true. Examples of particle-initiated coating defects are demonstrated in dependence on the origin and the field of application. Strategies for deliberate attachment/embedding of particles on surfaces/in coatings are discussed regarding process compatibility and coating integrity. For industrial applications, both the validation of process compatibility of particle injection and the plasma resistance of particles under vacuum and plasma conditions have to be confirmed. Further points of interest are the homogeneity of particle distribution and the avoidance of particle agglomeration which is still a crucial point for dry dispersed particles. So far, technical applications are limited to PVD hybrid coatings, plasma dispersion coatings are still a challenge except for applications where homogeneity is not required as in case of product authentication. T2 - ICMCTF 2018, International Conference on Metallurgical Coatings and Thin Films CY - San Diego, CA, USA DA - 23.04.2018 KW - PVD-coatings KW - PVD-processes KW - Unintended particle generation KW - Particles as imperfections KW - Deliberate particle implementation KW - Particles as add-on features PY - 2018 AN - OPUS4-44973 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Fischer, Daniel A1 - Hertwig, Andreas A1 - Mitzkus, Anja A1 - Sahre, Mario A1 - Weise, Matthias A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Basedau, Frank A1 - Hofmann, Detlef A1 - Schukar, Vivien A1 - Kormunda2, M. T1 - Multi-functional coatings for optical sensor applications: Surface plasmon resonance & magneto-optical coupling N2 - Multi-functional coatings are a key requirement for surface engineering. General demands are adhesion and long-term stability under service conditions. The modification of surfaces by means of PVD-, ECD- or hybrid processes allows an add-on functionalization of surfaces by a huge diversity of materials with both lateral and vertical micro-/nano-designs. This fact is a prerequisite for micro- and sensor-systems in lab-on-chip and sensor-on-chip technology. Two layer-based sensor principles are presented, i.e. surface plasmon resonance enhanced spectroscopic ellipsometry (SPREE) for detection of hazardous gases and magneto-optical sensors on smart-coated fiber Bragg gratings (FBG) for structural health monitoring (SHM). The interdependence of substrate features, coating properties, and layer design is discussed firstly for gas sensitivity and selectivity of SPREE-sensors and secondly for sensitivity and selectivity of magneto-strictive coatings to mechanical strain or external magnetic fields resulting in an optical displacement of the Bragg wavelength of FBG-sensors. Moreover, generic features such long-term stability, crucial process-related fabrication conditions, and effects of operational and environmental parameters are discussed with respect to the sensor performance. It has been shown that appropriate layer design and adapted selection of layer materials (SnOx/Au, Fe/Ni:SnOx/Au; Ni/NiFe-Cu-Cr) result in improved sensor parameters and may enable new sensor applications. T2 - SVC TechCon 2018 CY - Orlando, FL, USA DA - 05.05.2018 KW - Multi-functional coatings for sensors KW - Surface plasmon resonance enhanced ellipsometry (SPREE) KW - Gas monitoring KW - Magneto-optical coupling (MOC) KW - Structural health monitoring (SHM) PY - 2018 AN - OPUS4-44976 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Nirmalananthan-Budau, Nithiya A1 - Moser, Marko A1 - Geißsler, Daniel A1 - Behnke, Thomas A1 - Schneider, Ralf T1 - Simple and versatile methods for quantifying functional groups, ligands, and biomolecules on nanomaterials N2 - Many applications of nanomaterials in the life sciences require the controlled functionalization of these materials with ligands like polyethylene glycol (PEG) and/or biomolecules such as peptides, proteins, and DNA. This enables to tune their hydrophilicity and biocompatibility, minimize unspecific interactions, improve biofunction-nalization efficiencies, and enhance blood circulation times and is the ultimate prerequisite for their use as reporters in assays or the design of targeted optial probes for bioimaging. At the core of these functionalization strategies are reliable and validated methods for surface group and ligand quantification that can be preferably performed with routine laboratory instrumentation, require only small amounts of substances, and are suitable for many different types of nanomaterials. We present here versatile and simple concepts for the quantification of common functional groups, ligands, and biomolecules on different types of organic and inorganic nano-materials, using different types of optical reporters and method validation with the aid of multimodal reporters and mass balances. T2 - RSC Symposium on Nanoparticle concentration – critical needs and state-of-the-art measurement CY - London, UK DA - 24.04.2018 KW - PEG ligands KW - Surface group analysis KW - Upconverting nanoparticles KW - Integrating sphere spectroscopy KW - Absolute fluorescence quantum yield KW - Fluorescence decay kinetics PY - 2018 N1 - Geburtsname von Nirmalananthan-Budau, Nithiya: Nirmalananthan, N. - Birth name of Nirmalananthan-Budau, Nithiya: Nirmalananthan, N. AN - OPUS4-44986 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan A1 - Yamamoto, K. A1 - Grulke, E. A. A1 - Maurino, V. T1 - Shape controlled TiO2 nanoparticles as candidates for nano-CRM’s – an ISO case study N2 - Extraction of true, 3D shape (and size) of non-spherical nanoparticles (NPs) is associated with errors by conventional 2D electron microscopy using projection images. Significant efforts within the ISO technical committee TC 229 ‘Nanotechnologies’ are aimed at establishing accurate TEM and SEM measurement of NP size and shape as robust, standard procedures. Study groups have been organizing inter-laboratory comparisons on well-selected NP systems according to the market needs, such as aggregated titania nano-powder for which size and shape distribution of primary crystallites of irregular shape must be measured accurately. To be noticed is e. g. the fact that the measurement procedure allows only manual selection of the particles clearly distinguishable for analysis as well as manual definition of the contour of the imaged NPs. An inter-laboratory exercise on titania NPs (pure anatase, grown by hydrothermal synthesis) of well-defined non-spherical shape, i.e. bipyramidal has been recently started within ISO/TC 229 under similar conditions as for the irregular shaped titania. Overlapped particles were allowed to be considered, as long as they are clearly distinguishable. One decisive NP selection criterion was to analyze only those NPs with a roundness value below 0.7, i.e. the NPs laying on the support foil and, hence, with projection areas clearly deviating from perfect circles (R=1). The overall evaluation (for 15 labs) of the size descriptors (area, Feret, minFeret, perimeter) and shape descriptors (aspect ratio, roundness, compactness, extent) by analysis of variance is just to be finished and included in ISO/WD 21363 Nanotechnologies -- Protocol for particle size distribution by transmission electron microscopy. T2 - NanoWorkshop 2018 (Workshop on reference nanomaterials, current situation and needs: development, measurement, standardization) CY - Berlin, Germany DA - 14.05.2018 KW - Titanium oxide KW - Nanoparticles KW - Shape-controlled KW - Electron microscopy KW - Reference material PY - 2018 AN - OPUS4-44996 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Unger, Wolfgang T1 - Metrology for spatially resolved chemical analysis at the micro and nanometre scales Surface Analysis Working Group (SAWG) - Report for 16th Meeting (2017/18) N2 - Following the 2017 meeting, progress with the Key Comparison CCQM-K153 related to the BET specific surface lead by UNIIM and the Pilot Study P-190 “Thickness Measurement of nm HfO2 Films” lead by KRISS will be discussed. The 16th meeting of SAWG will focus on •survey on CMC claims submitted with reference to K-129 and K-136. •the overall and SAWG specific aspects of the CCQM Strategy process, •a consideration of comparisons on convention methods as recommended by the CCQM Plenary Meeting 2017, •the 2019 CCQM Workshop and paper(s) for Metrologia’s Special Issue, •discussion of future comparisons. T2 - 24th meeting of the CCQM 2018 CY - Paris, France DA - 19.04.2018 KW - Surface chemical analysis KW - Metrology KW - Inter-laboratory comparisons PY - 2018 AN - OPUS4-44998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -