TY - CONF A1 - Mirtsch, Mona A1 - Pohlisch, Jakob A1 - Blind, K. T1 - International Diffusion of the Information Security Management System Standard ISO/IEC 27001: Exploring the Role of Culture N2 - In the wake of digitalization, organizations are increasingly exposed to risks associated with security breaches and must take measures to preserve the confidentiality, integrity, and availability of information, and to ensure business continuity. The international standard ISO/IEC 27001 assists organizations in setting up, maintaining and continuously improving their information security management systems. However, despite high growth rates, its international diffusion rates are quite heterogeneous. This paper explores why the diffusion of the international management system standard ISO/IEC 27001 differs across countries. We classify the adoption of ISO/IEC 27001 as a ‘preventive organizational innovation’ and draw from diffusion studies of other management system standards and information security research to develop a set of hypotheses. These relate to the impact of cultural dimensions and national ICT development. We use a negative binomial regression model with panel data covering 57 countries over a 12-year period from 2006 to 2017 to test our hypotheses. We find that the cultural dimensions future orientation, power distance, and institutional collectivism as well as high ICT development are driving factors for the diffusion of ISO/IEC 27001. We derive policy recommendations and avenues for future research. T2 - Twenty-Eighth European Conference on Information Systems (ECIS2020) – A Virtual AIS Conference CY - Online meeting DA - 15.06.2020 KW - Information security KW - International diffusion KW - Standards KW - Management system standards KW - ISO/IEC 27001 KW - Preventive innovations KW - Culture KW - GLOBE KW - ICT development index PY - 2020 SP - RP 88 AN - OPUS4-50919 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mirtsch, Mona T1 - International Diffusion of the Information Security Management System Standard ISO/IEC 27001: Exploring the role of culture N2 - In the wake of digitalization, organizations are increasingly exposed to risks associated with security breaches and must take measures to preserve the confidentiality, integrity, and availability of information, and to ensure business continuity. The international standard ISO/IEC 27001 assists organizations in setting up, maintaining and continuously improving their information security management systems. However, despite high growth rates, its international diffusion rates are quite heterogeneous. This paper explores why the diffusion of the international management system standard ISO/IEC 27001 differs across countries. We classify the adoption of ISO/IEC 27001 as a ‘preventive organizational innovation’ and draw from diffusion studies of other management system standards and information security research to develop a set of hypotheses. These relate to the impact of cultural dimensions and national ICT development. We use a negative binomial regression model with panel data covering 57 countries over a 12-year period from 2006 to 2017 to test our hypotheses. We find that the cultural dimensions future orientation, power distance, and institutional collectivism as well as high ICT development are driving factors for the diffusion of ISO/IEC 27001. We derive policy recommendations and avenues for future research. T2 - Twenty-Eighth European Conference on Information Systems (ECIS2020) – A Virtual AIS Conference CY - Online meeting DA - 15.06.2020 KW - Information security KW - International diffusion KW - Standards KW - Management system standards KW - ISO/IEC 27001 KW - Preventive innovations KW - Culture KW - GLOBE KW - ICT development index PY - 2020 AN - OPUS4-50921 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Faßbender, Sebastian T1 - On-line species-specific isotopic analysis of sulfur by hyphenation of capillary electrophoresis with MC-ICP-MS N2 - In many scientific fields, isotopic analysis can offer valuable information. Up to date, typically bulk analysis is aimed at measuring the isotopic composition of the entire elemental content of the sample. However, the analyte element is usually present under the form of different species. Thus, separating species of interest from one another and from matrix components prior to isotope ratio measurements can provide species-specific isotopic information, which could be used for tracing the origin of environmental pollutants and elucidation of (environmental) speciation. Using on-line hyphenations of separation techniques with multicollector-ICP-MS (MC-ICP-MS) can save time and effort and enables the analysis of different species during a single measurement. Whereas some works hyphenating GC and IC with MC-ICP-MS have already been reported, LC and CE hyphenations are still inadequately represented based on the capabilities of these separation techniques. In this work, we developed an on-line hyphenation of CE with multicollector-ICP-MS (CE/MC-ICP-MS) for isotopic analysis of sulfur species using a multiple-injection approach for instrumental mass bias correction by standard-sample bracketing. With this method, the isotopic composition of sulfur in sulfate originating from river water could be analyzed without sample preparation. The results were compared to data from off-line analysis of the same samples to ensure accuracy. The precision of the results of the on-line measurements was promising regarding the differentiation of the river systems by the isotopic signature of river water sulfate. The great potential of this method is based on the versatility of the applied separation technique, not only in the environmental field but also for, e.g., biomolecules, as sulfur is the only covalently bound constituent of proteins that can be analyzed by MC-ICP-MS. T2 - Virtual Goldschmidt 2020 CY - Online meeting DA - 21.06.2020 KW - Isotopic analysis KW - Hyphenated techniques KW - Capillary electrophoresis KW - Multicollector-ICP-MS KW - Speciation analysis PY - 2020 AN - OPUS4-50922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kruschwitz, Sabine T1 - Challenges in Intelligent Computing for Non destructive testing in civil engineering – today and tomorrow N2 - A large amount of data and information is collected in the field of non-destructive testing (NDT) in civil engineering. The weakly structured data are usually evaluated with regard to specific testing tasks (e.g. geometry determination, damage localization, quality assurance). While the data offers great economic potential, i.e. to support construction planning, monitoring and maintenance processes, the evaluation is manual and case-by-case and therefore too inefficient for broader applications. We present recent visions and approaches how these large amounts of data need to be handled in the future and how we aim to make the acquired knowledge accessible to our stakeholders. Building on initiatives in materials research, we stress the importance of further research in the field of semantic data integration particularly motivate why an ontology is needed for the area of NDT in civil engineering. T2 - EG-ICE 2020 CY - Online meeting DA - 01.07.2020 KW - Data analysis KW - Non destructive testing KW - Computational engineering KW - AI PY - 2020 AN - OPUS4-50971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Haas, Marko ED - Hirsch, B ED - Weber, J ED - Schäfer, F ED - Schmid, J T1 - Das Risikomanagementsystem in der Bundesanstalt für Materialforschung und -prüfung (BAM) N2 - Im Rahmen des Bandes Management von Risiken in Behörden beschreibt der Praxisbeitrag das Risikomanagementsystem der BAM. KW - Risiko KW - Risikomanagement KW - Controlling KW - Management KW - Steuerung PY - 2020 SN - 978-3-503-19150-5 SP - 90 EP - 100 PB - Erich Schmidt Verlag CY - Berlin AN - OPUS4-50915 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. A1 - Sennikov, P. T1 - Laser Induced Plasma for Chemical Vapor Deposition: Theory and Experiment N2 - A possibility of deposition from laser-induced plasma (LIP) is investigated in search for an economic and simple method to obtain isotopic compounds from enriched gaseous precursors. A breakdown in mixtures of BCl3 and BCl3 with hydrogen, argon, and methane are studied both theoretically and experimentally. Calculations of expanding plasma of different composition are performed with the use of the fluid dynamic code coupled to the equilibrium chemistry solver. Condensed phases of boron, boron carbide, and graphite are predicted showing maximum concentrations in peripheral zones of the plasma. In experiment LIP is induced in mixtures BCl3, Н2+BCl3, H2+Ar+BCl3, H2+BCl3+CH4, BF3, Н2+BF3, H2+Ar+BF3, and H2+Ar+BF3. The gases are analyzed before, during, and after laser irradiation by optical and mass spectroscopic methods. The composition of reaction products is found to be close to that predicted theoretically. The conversion of precursor gases BCl3 and BF3 into gaseous and condensed products is 100% for BCl3 and 80% for BF3. Solid deposits of up to 30 mg are obtained from all the reaction mixtures. FTIR analysis of BCl3+H2+CH4 deposits points to a presence of condensed boron and boron carbide that are also predicted by the model. Both calculations and preliminary experimental results suggest the chemical vapor deposition by LIP is promising for conversion of gaseous enriched precursors into elemental isotopes and their isotopic compounds. T2 - International Online Meeting on Laser Induced Breakdown Spectroscopy (IIOMLIBS) CY - Online meeting DA - 06.07.2020 KW - Chemical vapor deposition KW - Laser induced plasma PY - 2020 AN - OPUS4-50994 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Haller, T. A1 - Völker, Christoph A1 - Hartmann, T. T1 - Machine learning based multi-sensor fusion for the nondestructive testing of corrosion in concrete N2 - Half-cell potential mapping (HP) is the most popular non-destructive testing method (NDT) for locating corrosion damage in concrete. It is generally accepted that HP is susceptible to environmental factors caused by salt-related deterioration, such as different moisture and chloride gradients. Additional NDT methods are able to identify distinctive areas but are not yet used to estimate more accurate test results. We present a Supervised Machine Learning (SML) based approach to data fusion of seven different signal features to obtain higher quality information. SMLs are methods that explore (or learn) relationships between different (sensor) data from predefined data labels. To obtain a representative, labelled data set we conducted a comprehensive experiment simulating the deterioration cycle of a chloride exposed device in the laboratory. Our data set consists of 18 measurement campaigns, each containing HP, Ground Penetrating- Radar, Microwave Moisture and Wenner resistivity data. We compare the performance of different ML approaches. Many outperform the best single method, HP. We describe the intrinsic challenges posed by a data-driven approach in NDT and show how future work can help overcome them. T2 - SMAR2019 - 5th International Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Structures CY - Potsdam, Germany DA - 27.08.2019 KW - Machine Learning KW - NDT KW - Half-Cell Potential Mapping KW - Corrosion KW - Reinforced Concrete KW - Data Fusion PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-498563 UR - http://www.ndt.net/?id=24890 VL - 25 IS - 1 SP - 24890-1 EP - 24890-8 PB - NDT.net CY - Kirchwald AN - OPUS4-49856 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Meermann, Björn T1 - Metal based pollutant assessment via diatoms - new possibilities via automated single cell-ICP-ToF-MS N2 - Diatoms are located at the bottom of the food chain. Toxicological relevant metals can possibly accumulate within the food web and cause harmful effects. Diatoms are a test system in ecotoxicology. Toxicological effects weaken the growth of algae which is by default investigated by means of fluorescence detection. On basis of the expose concentration as well as obtained fluorescence data potential threshold exceedance in e.g. surface waters is assessed. However, this approach does not allow for the determination of “real” accumulated metal concentration in diatoms. Common approaches are based on bulk analysis via e.g. ICP-MS, ICP-OES or AAS. But, biological variability is completely disregarded. To tackle this problem, alternative approaches are highly needed. Within the last years, sp-ICP-MS for nanoparticle as well as single cell analysis turned out as a powerful technique to analyze metal contents as well as size distributions on broad size range. But, common ICP-MS systems do not allow for multi-element detection within single particle/cell events. Thus, simultaneous MS detection devices are needed - just recently, ICP-ToF-MS experienced a revival. Within our previous work, we developed an automated sample introduction system based on a HPLC system on-line with single particle-ICP-MS, which allowed for ionic background separation and single algae analysis. However, for unambiguous tracing several fingerprint elements and multielement analysis in single algae (diatoms) is needed. Thus, we coupled our previous setup on-line to ICP-ToF-MS. Test diatom species were exposed to test substances (Zn) as well as nanoparticles (FeNPs). The developed setup allowed for a fast, automated and multielement analysis in single diatoms. Furthermore, we combined our approach with multivariate data assessment - multielement detection of characteristic fingerprint elements allowed for an unambiguous diatom tracing. Clustering of diatoms according to metal exposure concentration levels was enabled. Our approach is a new potential tool in ecotoxicological testing. T2 - 53. DGMS & 27th ICP-MS user meeting CY - Münster, Germany DA - 01.03.2020 KW - Single cell-ICP-ToF-MS KW - Diatoms KW - New ecotoxicological testing tools PY - 2020 AN - OPUS4-50644 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Braun, M.-T. A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Marquardt, E. A1 - Mayr, M. A1 - Nickel, H.-U. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. ED - Jonuscheit, J. ED - Marquardt, E. T1 - Terahertzsysteme und Anwendungsfelder N2 - Der Frequenzbereich der Terahertzwellen liegt im elektromagnetischen Spektrum zwischen den Mikrowellen und dem infraroten Licht – also etwa im Bereich von 0,1 bis 10 Terahertz (THz). Der VDI-Statusreport „Terahertzsysteme und Anwendungen“ stellt die unterschiedlichen Konzepte für Terahertzsysteme vor und zeigt Anwendungsbeispiele, bei denen die Terahertztechnik erfolgreich eingesetzt wird. Umfangreiche Literaturangaben ermöglichen eine intensivere Beschäftigung mit allen Themen des VDI-Statusreports. KW - Terahertzsysteme PY - 2020 UR - https://www.vdi.de/ueber-uns/presse/publikationen/details/terahertzsysteme-und-anwendungsfelder SP - 1 EP - 44 PB - Verein Deutscher Ingenieure (VDI) CY - Düsseldorf AN - OPUS4-50556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Alfeld, M. A1 - Eckhardt, H.-S. A1 - Kraft, J. A1 - Maiwald, Michael A1 - Meermann, Björn A1 - Merz, K. A1 - Prikler, S. A1 - Richert, J. A1 - Steiner, G. A1 - von Tümpling, W. T1 - Trendbericht Analytische Chemie N2 - Zusätzlich zu Methodenentwicklung, Miniaturisierung und Kopplungsverfahren zeigen sich die Hyperspektroskopie zusammen mit Imaging‐Verfahren, der Einzelmolekülnachweis und der Einsatz von 3‐D‐Druckern als neue Schwerpunkte. Hinzu kommen künstliche Intelligenz bei Sensoren, Bildgebungsverfahren und Prozesssteuerung sowie die Vernetzung von Analyse‐ und Laborgeräten. Trends und Forschungsthemen aus der analytischen Chemie, zusammengestellt von elf Autoren, koordiniert von Günter Gauglitz. KW - Multielementanalytik KW - Multimodale Analytik KW - Kristallolgraphie KW - Prozessanalytik KW - Prozessindustrie KW - Industrielle Analytik KW - Chemometrik KW - Chemometrie PY - 2020 DO - https://doi.org/10.1002/nadc.20204095786 SN - 1868-0054 VL - 68 IS - 4 SP - 52 EP - 60 PB - Wiley CY - Weinheim AN - OPUS4-50609 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Millar, Steven A1 - Gottlieb, Cassian A1 - Wilsch, Gerd A1 - Günther, Tobias A1 - Völker, Tobias T1 - Chemische Zustandsanalyse von Stahlbetonbauwerken mit der laserinduzierten Plasmaspektroskopie (LIBS) N2 - Die chemische Analyse von Beton gehört bei der Ermittlung des Ist-Zustandes von Stahl- und Spannbetonbauwerken zu den grundlegenden Untersuchungen bei der Zustandserfassung. Der tiefenabhängige Chloridgehalt sowie der Karbonatisierungsfortschritt müssen bei der Bewertung des Ist-Zustandes, beim Instandsetzungsbedarf und ggf. bei der Planung eines erforderlichen Instandsetzungskonzeptes mit einbezogen werden. Seit Mitte der 1990er Jahre wird an der Bundesanstalt für Materialforschung und -prüfung die laserinduzierte Plasmaspektroskopie (engl. Laser-induced Breakdown Spectroscopy) – kurz LIBS – stetig für die chemische Analyse von Beton weiterentwickelt. In diesem Beitrag wird der aktuelle Stand der Forschung/ Technik und der Normungsarbeit präsentiert, sowie zukünftig mögliche Anwendungen vorgestellt. Mit den aktuellen LIBS-Systemen (mobiles LIBS-System sowie kommerziell erhältliche Laborsysteme) ist es möglich den Chloridgehalt ortsaufgelöst in wenigen Minuten zu quantifizieren, sogenannte Elementlandkarten zu erstellen und somit die Elementverteilung innerhalb des Betons zu visualisieren. Durch das Scannen eines Bohrkernquerschnittes und der simultanen Erfassung von mehreren Elementen mit einer Messung, ist es zudem möglich, die Gesteinskörnung in den Messdaten zu identifizieren und den Chloridgehalt auf die Zementsteinmatrix zu beziehen. Fehlerquellen aus der Umrechnung der betonbezogenen Chloridgehalte können dadurch minimiert werden. Neben den Grundlagen von LIBS werden vor allem aktuelle Praxisbeispiele vorgestellt, die die aktuellen Möglichkeiten des Verfahrens veranschaulichen. T2 - 9. Kolloquium Parkbauten CY - Esslingen, Germany DA - 04.02.2020 KW - LIBS KW - Chemische Analyse KW - Spektroskopie KW - Beton PY - 2020 UR - https://elibrary.narr.digital/article/99.125005/kpb202010305 SN - 2510-7763 VL - 9 IS - 1 SP - 305 EP - 319 AN - OPUS4-50615 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Maiwald, Michael T1 - The internet of things in the lab and in process - The digital transformation challenges for the laboratory 4.0 T1 - Das Internet of Things in Labor und Prozess - Herausforderungen des digitalen Wandels für das Labor 4.0 N2 - It is a fact that much of the time spent on analytical laboratory instrumentation these days goes into system maintenance. Digital transformation could give us more time again for creativity and our actual laboratory work – if we shape it the right way. N2 - Fakt ist: Einen Großteil der Zeit, der an analytischen Laborgeräten verbracht wird, nimmt heute die Systempflege in Anspruch. Der digitale Wandel kann uns endlich wieder mehr Zeit für Kreativität und die eigentliche Laborarbeit geben – wenn wir ihn richtig gestalten. KW - Lab of the Future KW - Digitalisation KW - Automation KW - Data Analysis KW - Instrument Communication KW - Labor der Zukunft KW - Digitale Transformation KW - Automatisierung KW - Gerätekommunikation PY - 2020 IS - 4 SP - 1 EP - 3 PB - Lumitos AG CY - Darmstadt AN - OPUS4-50618 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas T1 - Monitoring of bridges with coda waves - first steps towards an imaging strategy N2 - Monitoring of concrete structures is of utmost importance in maintenance and preservation of infrastructure. As a part of the DFG research group CoDA (Concrete Damage Assessment by Coda Waves), the works within this PhD project aim for identification of damage sensitive parameters extracted from ultrasonic measurements obtained with embedded sensors, the determination of environmental (reversible) influences on the signal and the localisation of damaged areas. The main technique used for the detection of changes in the monitored material is the so-called Coda Wave Interferometry (CWI). It uses the later part of the ultrasonic recording for the detection of small changes in the sensed area and the calculation of a relative velocity change. Using this technique we can show that we are able to detect changes in concrete temperature with ultrasound measurements. This enables temperature correction for ultrasound monitoring with embedded sensors. The crucial point for imaging and localisation with coda waves is the calculation of the so-called sensitivity kernels. We propose the application of numerical wave simulations for the kernel calculations instead of the commonly used diffusivity equation. Using finite-difference wave modelling code from our DFG project partners we are able to calculate those Kernels and first results are shown in this presentation. The major task for the second year will be the development and implementation of the inversion algorithm as well as the preparation of validation experiments. T2 - Doktorandenseminar BAM Abt. 8 CY - Berlin, Germany DA - 30.03.2020 KW - Ultrasound KW - Non-destructive testing KW - Numerical modelling KW - Structural health monitoring PY - 2020 AN - OPUS4-50624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - Zentrifugentechnologie zur statistischen Untersuchung von Stumpfklebungen: Ergebnisse ZENSUS-Ringversuchs N2 - Der Vortrag widmet sich der „Zentrifugentechnologie zur statistischen Untersuchung von Stumpfklebungen“ und beschreibt drei wesentlich verschiedene Realsysteme (Fügefläche 1/Klebstoff/ Fügefläche 2), um die Statistik ZPM (wiederholte Ein-Proben-Prüfung) vs. CAT (Mehr-Proben-Prüfung) zu vergleichen. Dazu wurden drei unterschiedliche Klebstoff-klassen mit typischen Fügeteilmaterialkombinationen ausgewählt und in einem Vorversuch mit jeweils 3 unterschiedlichen Prüfgeschwindigkeiten sowohl im Weg-geregelten als auch Kraft-geregelten Mode beansprucht. Die Ergebnisse ZPM vs. CAT und Kraft- vs. Weg-Regelung des Vorversuches zeigten keinerlei Unterschiede auf. Im Ergebnis wurde ein Ringversuch im Kraft-geregelten Mode (6xZPM vs. 8xCAT) für ein Referenzsystem durchgeführt, der nachwies, dass die CAT-Technologie statistisch relevante Prüfergebnisse zur Klebfestigkeit bereitstellt. Es zeigte sich, dass für zwei ZPM-Teilnehmer im Vertrauensbereich 99% statistisch signifikant etwas kleinere Werte der Klebfestigkeit bestimmt wurden, was auf geringfügige Abweichungen von der axialen Ausrichtung des eingespannten Prüflings bei der Ein-Proben-ZPM-Zugprüfung zurückgeführt wird. T2 - VCI CY - Frankfurt/Main, Germany DA - 10.03.2020 KW - Zentrifugentechnologie KW - Statistischen Untersuchung KW - Normung KW - Prüfgeschwindigkeiten KW - Stumpfklebungen PY - 2020 AN - OPUS4-50581 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von der Au, Marcus T1 - SPE HR-CS GF MAS – A New Sum Parameter Method for Extractable Organically Bound Fluorine (EOF) in Surface Water N2 - Introducing fluorine into organic molecules leads to new chemical/physical properties. Up to now, the OECD identified and categorized 4730 per- and polyfluoroalkyl substances-related CAS numbers. Especially in the field of technical applications (e.g. surface coatings, fire extinguishing foams) as well as pharmaceuticals, fluorinated substances gain in importance. Thus, an increasing release of fluorinated compounds into the environment is expected. The high environmental persistence of perfluorinated compounds leads to the risk of bioaccumulation. Partially fluorinated substances (polyfluorinated compounds) undergo degradation; thus, further possible fluorine species occur, which may exhibit different toxic/chemical properties. However, current target methods (e.g., HPLC/MS-MS) are not applicable for a comprehensive screening as well as assessment of pollution. Thus, the poster presents a new sum parameter method for quantitative determination of extractable organically bound fluorine (EOF) in surface water samples. The method is based on solid-phase extraction (SPE) for fluorinated compounds as well as quantitative separation of interfering inorganic fluoride in combination with high-resolution-continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) for quantitative analysis. By means of this technique, the detection of high resolution molecular absorption spectra (MAS) is enabled upon the addition of a modifier and the formation of a diatomic molecule (e.g. GaF) After successful optimization of the SPE procedure (maximum concentration of extractable organic fluorine), enrichment factors of about 1000 were achieved, allowing for highly sensitive fluorine detection. Next to a species-unspecific response, limits of detection in the low nanogram per liter range were achieved and real surface water samples were analyzed. EOF values in the range of about 50-300 ng/L were detected. The developed method allows for a fast and sensitive as well as selective screening of organically bound fluorine (EOF) in surface water samples, helping to elucidate pollution hotspots as well as discharge routes. T2 - 2020 Winter Conference on Plasma Spectrochemistry CY - Tucson, AZ, USA DA - 12.01.2020 KW - SPE HR-CS GF MAS KW - Sum parameter KW - Fluorine Detection PY - 2020 AN - OPUS4-50352 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Plasma Fundamentals and Diagnostics N2 - This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, microreactions, pump and probe diagnostics, tomography, temporal and spatial resolution. Basis of plasma computer modeling will be presented. T2 - Winter Plasma Conference CY - Tucson, AZ, USA DA - 10.01.2020 KW - Plasma modeling KW - Thermal equilibrium KW - Plasma processes KW - Electron number density KW - Temperatures KW - Emission line profiles KW - Spatial information PY - 2020 AN - OPUS4-50324 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - Particle Scattering Simulations with Geant4: An Overview N2 - A brief overview over the capabilities of Geant4 is provided together with some example applications T2 - Seminar of the bioanalysis group CY - Universidad Nacional de Colombia, Bogotá, Columbia DA - 03.02.2020 KW - Geant4 KW - Geant4-DNA KW - MCS KW - Simulation KW - Monte-Carlo simulation KW - Particle scattering simulation KW - Dosimetry KW - Xrays KW - Electrons KW - Radiation PY - 2020 AN - OPUS4-50332 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - Hands on: Particle scattering simulations A practical introduction N2 - A practical introduction is given for the necessary steps to start with particle scattering simulations based on Geant4/Topas. T2 - Seminar of the bioanalysis group CY - Universidad Nacional de Colombia, Bogotá, Columbia DA - 04.02.2020 KW - Geant4 KW - Geant4-DNA KW - MCS KW - Monte-Carlo simulations KW - Simulations KW - Particle scattering simulation KW - Scattering KW - Topas PY - 2020 AN - OPUS4-50333 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Philipp, Rosemarie T1 - EURAMET.QM-S14 "Measurement capabilities for the quantification of ethanol in water" - Summary of results N2 - The presentation summarizes the results of the EURAMET key comparison QM-S14 “Measurement capabilities for the quantification of ethanol in water”. Possible options for the key comparison reference value are discussed. T2 - EURAMET TC-MC Meeting 2020 CY - Bern, Switzerland DA - 05.02.2020 KW - EURAMET KW - Key comparison KW - Ethanol in water PY - 2020 AN - OPUS4-50391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Isotope ratio working group at CCQM N2 - The presentation gives the reasons for initiation of an isotope ratio working group at CCQM level, describes the process and provides the auduince with the initial working plan. T2 - EURAMET TC-MC Workshop on Isotope Ratio Analysis CY - Bern, Switzerland DA - 05.02.2020 KW - Metrology KW - Absolute isotope ratio KW - Isotope ratio KW - Delta value PY - 2020 AN - OPUS4-50344 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - CCQM IRWG draft strategy for all elements except for noble gases and H, C, N, O N2 - The presentation describes the draft strategy for metalloids and semi-metals within the IRWG at CCQM. This includes the definition of the measurements space, a suitable set of key comparisons and pilot studies and a proposal for a harmonized CMC application. T2 - EURAMET TC-MC Workshop on Isotope Ratio Analysis CY - Bern, Switzerland DA - 05.02.2020 KW - CMC KW - Measurement space KW - Metrology KW - Isotope ratio PY - 2020 AN - OPUS4-50345 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Absolute isotope ratios - a proposed research topic N2 - An introduction into absolute isotope ratios is given, with application fields ranging from fundamental science to geochronology and forensics. This is followed by a proposal for developing new calibration approaches for obtaining absolute isotope ratios at unrivaled uncertainty levels. This new developments will set the basis for improvements in all scientific fields. T2 - EURAMET TC-MC Workshop on Isotope Ratio Analysis CY - Bern, Switzerland DA - 05.02.2020 KW - Absolute isotope ratio KW - Isotope fractionation KW - Metrology KW - Fundamental science PY - 2020 AN - OPUS4-50346 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Philipp, Rosemarie T1 - EURAMET.QM-S14 Measurement capabilities for the quantification of ethanol in water - Summary of results N2 - The presentation summarizes the results of the EURAMET key comparison QM-S14 “Measurement capabilities for the quantification of ethanol in water”. Possible options for the key comparison reference value are discussed. T2 - CCQM Organic Analysis Working Group videoconference CY - Online meeting DA - 05.06.2020 KW - Certified Reference Material KW - EURAMET KW - Key comparison PY - 2020 AN - OPUS4-50890 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - DNA basierte Dosimetrie N2 - We propose the development of a standardized DNA based dosimeter. This dosimeter will improve the comparability between the results of different laboratories in radiation research. Compared to conventional methods in dosimetry, this Approach provides direct access to the relation between radiation interaction and biological damage. Moreover, it enables the systematic investigation of the relation between the microscopic characteristics of radiation and DNA damage over a wide dose range. T2 - Zertkom CY - Online meeting DA - 13.05.2020 KW - DNA KW - Dosimetrie KW - Dosimetry KW - Effective dose KW - Energy dose KW - Energiedosis KW - Equivalent dose KW - Absorbed dose PY - 2020 AN - OPUS4-50779 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ahmadi, Samim A1 - Hirsch, Philipp Daniel A1 - Lecompagnon, Julien A1 - Hassenstein, Christian A1 - Jung, P. A1 - Caire, G. A1 - Ziegler, Mathias T1 - New techniques in super resolution photothermal imaging for nondestructive testing N2 - In this work we focus on our most recent studies to super resolution (SR) laser thermography. The goal of SR nondestructive testing methods is to facilitate the separation of closely spaced defects. We explain how to combine laser scanning with SR techniques. It can be shown that stepwise as well as continuous scanning techniques are applicable. Finally, we discuss the effect of experimental parameters and im-age processing techniques to find the optimal SR technique which leads to the highest reconstruction quality within laser thermography. T2 - SMSI 2020 Conference CY - Online meeting DA - 22.06.2020 KW - Super resolution KW - Laser thermography KW - Nondestructive testing KW - Laser scanning KW - Photothermal imaging PY - 2020 DO - https://doi.org/10.5162/SMSI2020/C4.1 SP - 169 EP - 170 AN - OPUS4-50895 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias A1 - Ahmadi, Samim A1 - Hirsch, Philipp Daniel A1 - Lecompagnon, Julien A1 - Hassenstein, Christian A1 - Thiel, Erik A1 - Pech May, Nelson Wilbur T1 - Using spatial and temporal shaping of laser-induced diffuse thermal wave fields in thermography N2 - The diffuse nature of thermal waves is a fun-damental limitation in thermographic nonde-structive testing. In our studies we investigated different approaches by shaping the thermal wave fields which result from heating. We have used high-power laser sources to heat metallic samples. Using these spatial and temporal shaping techniques leads to a higher detection sensitivity in our measurements with the infra-red camera. In this contribution we show our implementation of shaping laser-induced diffuse thermal wave fields and the effect on the defect reconstruction quality. T2 - SMSI 2020 Conference CY - Online meeting DA - 22.06.2020 KW - Thermal wave KW - Diffusion KW - High-power laser KW - Thermography KW - Spatiotemporal shaping PY - 2020 DO - https://doi.org/10.5162/SMSI2020/C5.1 SP - 179 EP - 180 AN - OPUS4-50897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stephan-Scherb, Christiane T1 - Applied Crystallography as a tool for a better understanding of Fundamental Questions of high temperature corrosion phenomena N2 - Corrosion Science Meets X-Rays, Neutrons and Electrons. The presentation gives an overview on current research activities applying in-situ X-ray diffraction and spectroscopy for a better understanding of fundamental mechanisms of high temperature corrosion. Additionally the knowledge gain by applying neutron powder diffraction and EBSD analysis is presented. T2 - Joint meeting of german and polish crystallographic association 2020 CY - Wroclaw, Poland DA - 24.02.2020 KW - Corrosion KW - Oxidation KW - In situ KW - Diffraction PY - 2020 AN - OPUS4-50483 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steger, Simon T1 - Spectroscopic analysis of colourants and binders of Chinese reverse glass paintings tracing a cultural dialogue N2 - Scientific analysis based on spectroscopic methods provide essential information on the composition of colourants and binders in paintings. These results can be set in a historical context and help to confirm art historical interpretations. Proofs of certain pigments can be used for dating purposes and may reveal if the artist used not only local but also imported materials. A pilot study of two Chinese reverse glass paintings from the late 19th (Yingying and Hongniang) and early 20th centuries (The Archer) was performed using a multi-analytical approach including X-ray fluorescence (XRF), diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and Raman spectroscopy. This approach allowed the identification of the pigments and the classification of the binding media. The results reveal a combined use of traditional Chinese and imported European materials. Several pigments like cinnabar, lead white, orpiment, carbon black and copper-arsenic green (probably emerald green) were found in both paintings; red lead, artificial ultramarine blue, Prussian blue and ochre appear in at least one of the paintings. The proof of limewash (calcite and small amounts of portlandite) as a backing layer in “Yingying and Hongniang” indicates that clamshell white was also used for reverse glass paintings. Drying oil was classified as a binding media in most areas of both paintings. However, the orange background of The Archer yielded prominent bands of both proteinaceous and fatty binder. T2 - China and the West Reconsidering Chinese Reverse Glass Painting CY - Romont, Switzerland DA - 14.02.2020 KW - Reverse glass painting KW - DRIFTS KW - Raman spectroscopy PY - 2020 AN - OPUS4-50445 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Casperson, Ralf T1 - Datenformate für die zerstörungsfreie Prüfung N2 - Der Vortrag gibt eine Übersicht über die Versuche der Vergangenheit, ein standardisiertes Datenformat für die zerstörungsfreie Prüfung zu etablieren. T2 - 4. Sitzung DGZfP FA ZfP 4.0 UA Schnittstellen CY - Stockelsdorf, Germany DA - 19.02.2020 KW - ZfP KW - Datenformat KW - TRAPPIST KW - STEP KW - NDTML KW - DICONDE KW - HDF5 PY - 2020 AN - OPUS4-50448 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Faßbender, Sebastian T1 - On-line hyphenation of CE with multicollector-ICP-MS for species-specific isotopic analysis of sulfur N2 - In many scientific fields, isotopic analysis can offer valuable information, e.g., for tracing the origin of food products, environmental contaminants, forensic and archaeological samples (provenance determination), for age determination of minerals (geochronological dating) or for elucidating chemical processes. Up to date, typically bulk analysis is aimed at measuring the isotopic composition of the entire elemental content of the sample. However, the analyte element is usually present under the form of different species. Thus, separating species of interest from one another and from matrix components prior to isotope ratio measurements can provide species-specific isotopic information, which could be used for tracing the origin of environmental pollutants and elucidation of (environmental) speciation. Using on-line hyphenations of separation techniques with multicollector-ICP-MS (MC-ICP-MS) can save time and effort and enables the analysis of different species during a single measurement. In this work, we developed an on-line hyphenation of CE with multicollector-ICP-MS (CE/MC-ICP-MS) for isotopic analysis of sulfur species. With this method, the isotopic composition of sulfur in sulfate originating from river water could be analyzed without sample preparation. The results were compared with data from off-line analysis of the same samples to ensure accuracy. The precision of the results of the on-line measurements was high enough to distinguish the rivers from one another by the isotopic signature of the river water sulfate. Next to environmental applications, a future field could be species-specific isotopic analysis of biomolecules, as sulfur is the only covalently bound constituent of proteins which can be analyzed by MC-ICP-MS. T2 - DGMS 2020 CY - Münster, Germany DA - 01.03.2020 KW - Capillary electrophoresis KW - Hyphenated techniques KW - Isotopic analysis KW - Multicollector-ICP-MS KW - Speciation analysis PY - 2020 AN - OPUS4-50501 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von der Au, Marcus T1 - HR-CS-GF-MAS as a new screening method for emerging pollutants - per- and polyfluorinated substances in the environment N2 - The introduction of fluorine in organic molecules leads to new chemical/physical properties. Especially in the field of pharmaceuticals, fluorinated organic molecules are becoming more and more popular and at present amount up to 25% of market share, with an upward trend. The main benefits of fluorinated pharmaceuticals are: (i) enhanced fat solubility; (ii) enhanced interaction of catalytic-center of enzymes with fluorine-drugs; (iii) a delayed metabolism within the human body. Highly fluorinated organic substances are also used in technical applications (e.g. coatings, fire-extinguishing agents). Due to the broad variety of fluorinated substances and increasing production volumes numerous and up to date unknown fluorine-species are most likely to be present in the (aquatic) environment. Analytical methods to assess the degree of contamination of surface waters with organically bound fluorine are highly needed and up to now only combustion ion chromatography based method is available, which is relatively laborious. Since a few years’ high resolution-continuum source-graphite furnace atomic absorption spectrometers (HR-CS-GFAAS) are commercially available from Analytik Jena. By means of this technique, the detection of high resolution molecular absorption spectra (MAS) is enabled. Thus, fluoride is detectable upon the addition of a modifier and the formation of a diatomic molecule (e.g. GaF). Just recently, we applied this technique for total fluorine (mainly dissolved fluoride) analysis in river water samples. In the present work a HR-CS-GFMAS method for extractable organically bound fluorine (EOF) analysis in surface water samples was developed by us. The method is based on SPE extraction of organically bound fluorine even in the presence of high fluoride concentrations followed by HR-CS-GFMAS analysis upon elution. Due to high enrichment factors, LODs in the low ng/L range were achieved. We successfully applied our SPE HR-CS-GFMAS method to Rhine water samples and EOF in the range of about 50-300 ng/L was detectable. T2 - DGMS 2020 CY - Münster, Germany DA - 01.03.2020 KW - SPE HR-CS GF MAS PY - 2020 AN - OPUS4-50503 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von der Au, Marcus T1 - HR-CS-GF-MAS as a new screening method for emerging pollutants - per- and polyfluorinated substances in the environment N2 - The introduction of fluorine in organic molecules leads to new chemical/physical properties. Especially in the field of pharmaceuticals, fluorinated organic molecules are becoming more and more popular and at present amount up to 25% of market share, with an upward trend. The main benefits of fluorinated pharmaceuticals are: (i) enhanced fat solubility; (ii) enhanced interaction of catalytic-center of enzymes with fluorine-drugs; (iii) a delayed metabolism within the human body. Highly fluorinated organic substances are also used in technical applications (e.g. coatings, fire-extinguishing agents). Due to the broad variety of fluorinated substances and increasing production volumes numerous and up to date unknown fluorine-species are most likely to be present in the (aquatic) environment. Analytical methods to assess the degree of contamination of surface waters with organically bound fluorine are highly needed and up to now only combustion ion chromatography based method is available, which is relatively laborious. Since a few years’ high resolution-continuum source-graphite furnace atomic absorption spectrometers (HR-CS-GFAAS) are commercially available from Analytik Jena. By means of this technique, the detection of high resolution molecular absorption spectra (MAS) is enabled. Thus, fluoride is detectable upon the addition of a modifier and the formation of a diatomic molecule (e.g. GaF). Just recently, we applied this technique for total fluorine (mainly dissolved fluoride) analysis in river water samples. In the present work a HR-CS-GFMAS method for extractable organically bound fluorine (EOF) analysis in surface water samples was developed by us. The method is based on SPE extraction of organically bound fluorine even in the presence of high fluoride concentrations followed by HR-CS-GFMAS analysis upon elution. Due to high enrichment factors, LODs in the low ng/L range were achieved. We successfully applied our SPE HR-CS-GFMAS method to Rhine water samples and EOF in the range of about 50-300 ng/L was detectable. T2 - DGMS 2020 CY - Münster, Germany DA - 01.03.2020 KW - SPE HR-CS GF MAS PY - 2020 AN - OPUS4-50504 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lemke, Nora T1 - Sulfur isotope dilution ICP MS for traceable protein quantification N2 - Inductively coupled plasma mass spectrometry (ICP-MS) is a powerful method for the matrix-independent quantitative analysis of target elements. Developed for the use in inorganic trace analysis, ICP-MS is nowadays a valuable tool for bioanalytical questions. Especially the use of ICP-MS for quantitative proteomics by measuring heteroatoms has gained recognition in the last decade, considering that established quantification methods like organic mass spectrometry depend on labelling of the target protein or the existence of matched protein and peptide standards. The need for reliable quantification of proteins is continuously growing, but only a limited number of well-characterized and quantified protein standards are available so far. Accurately quantified, traceable protein standards are necessary to ensure comparability of measurements between laboratories, not only in basic research but also in a clinical context. One example of this is the Alzheimer’s disease biomarker tau protein. However, existing tau standards lack comparability, emphasizing the need for a well-quantified protein standard. Therefore, we developed a method for the quantification of pure proteins via sulfur isotope dilution ICP-MS (IDMS). As sulfur is present in two amino acids, cysteine and methionine, it exists in nearly all proteins and can be used for the quantification of proteins of known stoichiometry. We employed simple offline strategies for the separation of non-protein bound sulfur species. Quantification of these contaminations by IDMS allows for correction of the protein content and enables reliable protein quantification. We report the protein mass fractions of a standard reference material and commercially available proteins determined by sulfur IDMS, including the expanded uncertainties. The developed method can be applied for the reliable and traceable quantification of pure proteins for use as in-house standards. Here, we successfully used this method for the quantification of the tau protein. T2 - 53rd annual conference of the DGMS including 27th ICP-MS User's Meeting CY - Münster, Germany DA - 01.03.2020 KW - ICP-MS KW - Isotope dilution KW - Protein KW - Quantification KW - Tau protein PY - 2020 AN - OPUS4-50510 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hein, Sebastian T1 - Ansätze und Herausforderungen für das QM-System einer Ressortforschungseinrichtung N2 - Die BAM betreibt ein QM-System, das stark an der DIN EN ISO/IEC 17025 orientiert ist und welches in den meisten Fachabteilungen durch Akkreditierungen untersetzt wird. Mit der Zunahme der Forschungsaktivitäten in den letzten Jahren ist der DFG-Kodex zur Sicherstellung der Guten wissenschaftlichen Praxis deutlicher in den Fokus des Qualitätsmanagements gerückt. Der Vortrag zeigt auf, welche QM-Anforderungen an die Leistungen der BAM gestellt werden und mit welchen Instrumenten sie diese umsetzt, so dass Gute wissenschaftliche Praxis und Akkreditierungen gut harmonieren können. T2 - QM-Seminar; Robert-Koch-Institut CY - Berlin, Germany DA - 21.01.2020 KW - Qualitätsmanagement KW - Gute wissenschaftliche Praxis PY - 2020 AN - OPUS4-50311 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lauschkin, Maik A1 - Bulling, Jannis A1 - Lugovtsova, Yevgeniya A1 - Wasmer, P. A1 - Prager, Jens T1 - Bestimmung von Materialparametern aus dem dispersiven Verhalten geführter Wellen mittels neuronaler Netze N2 - Damit eine Simulationsrechnung, beispielsweise mit einer FEM-Software, eine ausreichend hohe Genauigkeit erreicht, muss vorausgesetzt werden, dass die Modellparameter eine sehr hohe Güte aufweisen. Die genaue Kenntnis der Materialparameter ist dabei von besonderer Bedeutung. Um diese Parameter bestimmen zu können, müssen die verwendeten Werkstoffe messtechnisch charakterisiert werden. Neben anderen Ansätzen sind dafür akustische Verfahren im Ultraschallbereich geeignet. Für dünnwandige und plattenförmige Materialien können aus den sich ausbreitenden geführten Wellen messtechnisch Dispersionskurven bestimmt und aus diesen die Materialparameter abgeleitet werden. Da für die Signalverarbeitung und für Optimierungsaufgaben aktuell zunehmend Machine Learning Tools zum Einsatz kommen, stellt sich die Frage, ob diese Werkzeuge auch für die Ermittlung der Materialparameter aus den gemessenen Dispersionskurven eingesetzt werden können. In der vorgestellten Untersuchung soll ein Convolutional Neural Network aufgestellt werden, welches aus Dispersionsbildern Muster extrahiert und aus diesen eine Schätzung für die Materialparameter ermittelt. Um die Machbarkeit dieses Ansatzes zu prüfen, werden zunächst nur isotrope Materialien betrachtet. Für das Netz werden mit der Scaled-Boundary-Finite-Element-Methode synthetische Daten für das Trainieren und Validieren generiert. Zusätzlich werden die Hyperparameter des neuronalen Netzes variiert, um ein optimales Model für die Schätzung zu finden. Anschließend kann das Netz mit experimentellen Daten getestet und das Ergebnis hinsichtlich der Genauigkeit bewertet werden. T2 - DAGA 2020 - 46. Jahrestagung für Akustik CY - Meeting was canceled DA - 16.03.2020 KW - Machinelles Lernen KW - Geführte Ultraschallwellen KW - Materialcharakterisierung KW - Elastische Konstanten KW - Isotrope Materialien PY - 2020 SN - 978-3-939296-17-1 SP - 571 EP - 574 PB - Deutsche Gesellschaft für Akustik e.V. CY - Berlin AN - OPUS4-50765 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Marquardt, Julien T1 - Investigating the morphology of nanostructured mixed metal oxides (Ir/TiOx) and its impact on the electrocatalytic OER-activity N2 - The electrocatalytic conversion of water into molecular hydrogen and oxygen under the utilization of excess renewable energies, such as wind power, photovoltaics and hydroelectric power is one possible pathway to establish a sustainable hydrogen economy. The obtained hydrogen is either stored and used in a fuel cell or consumed on-site in industrial applications. Water electrolysis systems (WES) are based on two half cell reactions, such as oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) which both proceed simultaneously. The OER suffers from slow reaction kinetics and thus limits the overall performance. The most promising compounds in acidic electrolysis are IrO2 and RuO2. Due to their rare abundance and extremely high price a wide use of acidic WES was prevented. Lowering the catalysts noble metal content by mixing iridium with titanium reduces the production costs. Thin films are produced by dip coating a solution of metal oxide precursors alongside with a polymer template dissolved in ethanol. The obtained samples are subsequently calcined to the remove the template and adjust crystallinity. Finally, an additional iridium deposition step was performed on the outer surface plane area. Understanding the influence of structural and morphological aspects on the OER-activity is beneficial to further optimize WES. The current presentation will thus give detailed insights to structural aspects obtained by Raman spectroscopy, small- and wide-angle X-ray scattering which are then combined with electrochemical parameters to deduce structure-activity relationships. T2 - Joint Polish-German Crystallographic Meeting 2020 CY - Wrocław, Poland DA - 24.02.2020 KW - nanostructured KW - electrocatalysis PY - 2020 AN - OPUS4-50664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pohl, Rainer A1 - Casperson, Ralf A1 - Ehlers, Henrik A1 - Pelkner, Matthias T1 - Elektromagnetische zerstörungsfreie Prüfverfahren N2 - Übersicht über die die im FB 8.4 bearbeiteten elektromagnetischen Prüfverfahren mit den Schwerpunkten bildgebende Wirbelstromprüfung, sensorbasierte Streuflussprüfung, magnetische Materialcharakterisierung und Sondenentwicklung. KW - Wirbelstromprüfung KW - Wirbelstromsenoren KW - GMR-Sensoren KW - Magnetische Materialcharakterisierung PY - 2020 SP - 1 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-51033 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Maiwald, Michael T1 - On the way to the cyber-physical lab T1 - Auf dem Weg zum cyber-physical Lab N2 - Laboratories tend to be central hubs for chemical, biotechnological, pharmaceutical or foodstuff production. They play a key role in research and development, chemical analysis, quality assurance, maintenance and process control. For process development and optimization, process analytical technology (PAT) has proven to be a powerful tool to improve our understanding of processes, increase productivity, reduce waste and costs and shorten processing times. N2 - Im Allgemeinen sind Laboratorien zentrale Drehscheiben für die chemische, biotechnologische, pharmazeutische oder Lebensmittelproduktion. Sie spielen eine Schlüsselrolle in Forschung und Entwicklung, chemischer Analytik, Qualitätssicherung, Instandhaltung und Prozesskontrolle. Für die Prozessentwicklung und -Optimierung hat sich die Prozessanalysentechnik (PAT) als leistungsfähiges Werkzeug erwiesen, um das Prozessverständnis zu verbessern, die Produktivität zu steigern, Abfall und Kosten zu reduzieren und die Prozesszeit zu verkürzen. KW - Lab of the Future KW - Digitalisation KW - Cyber-physical Lab KW - Smart Laboratoy PY - 2020 SP - 1 EP - 3 PB - Lumitos AG CY - Darmstadt AN - OPUS4-51036 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Matthias T1 - Characterization of Surface Topometry and Determination of Layer Thickness by Scanning White Light Interference Microscopy N2 - 3D coherence scanning interferometry (CSI) is an optical, non-contact and rapide measurement technique using a defined bandwidth of white light at normal incidence. Based on this operational principle, white light interference microscopy (WLIM) provides three-dimensional surface topometry data up to a resolution of 0.4 μm lateral and 0.1 nm vertical. Three operating modi, i.e. surface, films and advanced films, enable measurements of step heights, roughness, wear volume, cone angle, surface pattern and layer thickness of transparent coatings. The determination of layer thickness by WLIM requires the knowledge of optical constants, i.e.the refractive index n and the extinction coefficient k. For technical surfaces, data base values - if available at all - have to be determined or validated by spectroscopic ellipsometry (SE). From this oblique incidence technique both optical constants and layer thickness can be derived based on a model for at least semi-transparent coatings. For different layer thicknesses, a comparison is made between WLIM and SE. Measurement uncertainty is discussed for both topometric features and layer thickness for different use cases. Traceability to SI system is ensured by certified standards (PTB/NIST) within a DAkkS DIN EN ISO/IEC 17025:2018 accredited lab. T2 - 17th International Conference on Plasma Surface Engineering (PSE) CY - Erfurt, Germany DA - 07.09.2020 KW - Rroughness and step heights KW - Lateral surface pattern KW - Layer thickness of transparent coatings KW - Scanning white light interferometry KW - Spectroscopic ellipsometry PY - 2020 AN - OPUS4-51301 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Denkler, Tilman T1 - EA-HHC - Analysis of the operation of accreditation bodies - Results of the 2nd round N2 - In 2019 the German federal institute Bundesanstalt für Materialforschung und –prüfung (BAM) conducted a benchmarking to compare the operations of European accreditation bodies and to identify best practices, with the aim of improving key processes in accreditation. Ten European accreditation bodies attended the comparison, four of which had already taken part in the pilot phase of the benchmarking project, which was conducted in 2017 by the German accreditation body Deutsche Akkreditierungsstelle GmbH (DAkkS) and the BAM. The study, designed to examine and compare the operation of accreditation bodies in Europe, used a management tool called Process Maturity Benchmarking Tool, which was especially elaborated and validated for this purpose in the pilot phase, in order to determine the values of indicators, thus enabling a comparison of the accreditation bodies despite different operational processes and organizational forms. The management tool is based on the analysis of selected processes with high relevance for the operation of accreditation bodies. The processes are derived from a process map designed for accreditation bodies in a universally applicable way. The indicators used to characterize the processes come from two sources: The first source relates to data already available from internal databases, reports, financial audits, and others. The second source is derived from the self-evaluation of process maturity performed by the accreditation bodies. The criteria for evaluating process maturities were designed by applying the criteria of the EFQM excellence model 2013 of the European Foundation for Quality Management (EFQM) to the processes identified in the process map. The results of the analysis were presented to and discussed with representatives of the ten accreditation bodies at a Results-Workshop that took place at BAM on 21/22 January 2020. In this presentation a wrap-up of the results was given to the HHC of EA T2 - Tagung des HHC (horizontal harmonization committee) der EA (European co-operation for accreditation) (virtuelles Meeting per MS-Teams, ca. 55 Teilnehmer) CY - Online meeting DA - 15.09.2020 KW - Accreditation KW - Benchmarking PY - 2020 AN - OPUS4-51251 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe A1 - Fischer, Daniel T1 - MISTRAL-Müller-Matrix-basierte Identifizierung von Inhomogenitäten und strukturellen Anomalien N2 - Mit abbildender Ellipsometrie (imaging ellipsometry: IE) können Nanometer-Beschichtungen/ Degradationen visualisiert und bezüglich Brechungsindex n, Extinktionskoeffizient k und Schichtdicke d charakterisiert werden. Materialseitig werden lokal Homogenität und Isotropie innerhalb eines/mehrerer Bildpunkte (field of analysis: FOA) und messtechnisch global die Ebenheit der Proben bezüglich aller Bildpunkte des Messfeldes vorausgesetzt. Für die Müller-Matrix-basierte abbildende Ellipsometrie (MM-IE), die den optischen Response anisotroper Materialien in jedem Bildpunkt über die bis zu 16 Müller-Matrix-Elemente erfasst, ist dies von besonderer Relevanz. Reale Substrate sind aber oft nicht eben, können lokal Noppen/Mulden (im FOA) aufweisen oder sind global konvex/ konkav im möglichen Messfeld (field of view: FOV) gekrümmt. Diese lokalen/globalen strukturellen Anomalien des Substrats werden schon für die IE messtechnisch/modellseitig oft nicht beherrscht und sind für die MM-IE in der Wirkung auf die MM-Elemente unbekannt. Diese Defizite sollen messtechnisch bzw. modellmäßig behoben und somit die Messung lokal/global gekrümmter Oberflächen ermöglicht werden (MM-CSIE, CS curved surface). KW - Abbildende Ellipsometrie (IE) KW - Müller-Matrix Ellipsometrie (MM-IE) KW - Gekrümmte Oberflächen KW - Schichtdicke KW - Optische Konstanten PY - 2020 SP - 1 EP - 7 AN - OPUS4-51574 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klewe, Tim A1 - Strangfeld, Christoph A1 - Ritzer, Tobias A1 - Kruschwitz, Sabine T1 - Nondestructive determination of moisture damage in layered building floors N2 - In this ongoing research project, we study the influence of moisture damage on Ground Penetrating Radar (GPR) in different floor constructions. For this purpose, a measurement setup with interchangeable layers is developed to vary the screed material (cement or anhydrite) and insulation material (glass wool, perlite, expanded and extruded polystyrene), as well as the respective layer thickness. The evaluation of the 2 GHz common-offset radar measurements is focused on the extraction of distinctive signal features that can be used to classify the underlying case of damage without any further information about the hidden materials or layer thicknesses. In the collected dataset, we analyze the horizontal distribution of A-scan features in corresponding B-scans to detect water in the insulation layer. Furthermore, possible combinations of these features are investigated with the use of multivariate data analysis and machine learning (logistic regression) in order to evaluate the mutual dependencies. In this study, the combination of an amplitude- and frequency-based feature achieved an accuracy of 93.2 % and performed best to detect a damage in floor insulations. T2 - 18th International Conference on Ground Penetrating Radar CY - Meeting was canceled DA - 14.07.2020 KW - Radar KW - Feuchte KW - Moisture KW - Building floors PY - 2020 DO - https://doi.org/10.1190/gpr2020-045.1 SN - 2159-6832 SP - 164 EP - 167 AN - OPUS4-51575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Luftultraschall N2 - Dieser Vortrag bietet eine Einführung zur luftgekoppelten Ultraschallprüfung. Es werden die theoretischen Grundlagen erläutert und Beispiele für Anwendungen in der Praxis gegeben. T2 - Schulung Ultraschallprüfung Stufe 3 CY - Berlin, Germany DA - 28.09.2020 KW - Luftgekoppelte Ultraschallprüfung KW - Luftankopplung KW - Ultraschallwandler PY - 2020 AN - OPUS4-51578 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weber, K. T1 - Diagenetic stability of Ca, Mg, Zn and Sr isotopes in teeth N2 - Stable isotope ratios and trace element concentrations of fossil bones and teeth are important geochemical proxies for the reconstruction of diet and past environment in archaeology and palaeontology. However, since diagenesis can significantly alter in vivo incorporated isotope signatures and elemental compositions, it is important to understand alteration processes. Here, we present the results of in vitro alteration experiments of dental tissues from a modern African elephant molar in aqueous solutions at 30 °C and 90 °C for 4 to 63 days each. Dental cubes with ≈3 mm edge length, comprising both enamel and dentin, were placed into 2 ml of an acidic (HNO3) aqueous solution (pH ≈1) enriched with different isotopes (25Mg, 44Ca, 67Zn, 86Sr). Element and isotope distribution profiles across the different dental cubes were measured with LA-(MC-)ICP-MS and EMPA, while potential changes of the bioapatite crystal structure were characterised by Raman spectroscopy. Isotope ratios measured by LA-(MC-)ICP-MS revealed an alteration of the outer ≈200-300 μm of the enamel in all experiments. Dentin was fully altered after one week (at 90 °C) and the tracer solution started to penetrate through the dentin even into the innermost enamel. However, the central part of the enamel remained unaltered. The Raman spectra suggest a strong recrystallization in the dentin and in the outer ≈40 μm of the enamel and a partial demineralisation of the outer rim of the cubes. Our results indicate that independent of time, temperature or low initial pH, enamel apatite shows a high resistance against the experimental alteration in structure and isotopic composition, in contrast to dentin apatite. T2 - Goldschmidt Conference CY - Online meeting DA - 21.06.2020 KW - Isotope ratio KW - Diagenesis KW - Alteration KW - Bio-apatite PY - 2020 AN - OPUS4-51499 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Faßbender, Sebastian T1 - On-line Species-specific Isotopic Analysis of Sulfur by Hyphenation of Capillary Electrophoresis with Multicollector-ICP-MS N2 - In many scientific fields, isotopic analysis can offer valuable information. Up to date, typically bulk analysis is aimed at measuring the isotopic composition of the entire elemental content of the sample. However, the analyte element is usually present under the form of different species. Thus, separating species of interest from one another and from matrix components prior to isotope ratio measurements can provide species-specific isotopic information, which could be used for tracing the origin of environmental pollutants and elucidation of (environmental) speciation. Using on-line hyphenations of separation techniques with multicollector-ICP-MS (MC-ICP-MS) can save time and effort and enables the analysis of different species during a single measurement. Whereas some works hyphenating GC and IC with MC-ICP-MS have already been reported, LC and CE hyphenations are still inadequately represented based on the capabilities of these separation techniques. In this work, we developed an on-line hyphenation of CE with multicollector-ICP-MS (CE/MC-ICP-MS) for isotopic analysis of sulfur species using a multiple-injection approach for instrumental mass bias correction by standard-sample bracketing. With this method, the isotopic composition of sulfur in sulfate originating from river water could be analyzed without sample preparation. The results were compared to data from off-line analysis of the same samples for validation. The repeatability of the results of the on-line measurements was promising regarding the differentiation of the river systems by the isotopic signature of river water sulfate. The great potential of this method is based on the versatility of the applied separation technique, not only in the environmental field but also for, e.g., biomolecules because sulfur is the only covalently bound constituent of proteins that can be analyzed by MC-ICP-MS. T2 - SciX 2020 CY - Online meeting DA - 12.10.2020 KW - Capillary electrophoresis KW - Hyphenated techniques KW - Isotopic analysis KW - Speciation analysis PY - 2020 AN - OPUS4-51402 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mirtsch, Mona A1 - Koch, Claudia T1 - Nutzung und Wirkung von (zertifizierten) Managementsystemen – aktuelle Erkenntnisse N2 - Ergebnisvorstellung im mitgliederexklusiven Webinar der Deutschen Gesellschaft für Qualität - DGQ zur Nutzung und Wirkung von genormten Managementsystemen als die erste Erhebung im Rahmen von QI-FoKuS. Neben der Motivation hinsichtlich der Anwendung verschiedener Normen, die Anforderungen an Managementsysteme darlegen, sowie den Wirkungen werden insbesondere die Zertifizierung für diese Normen sowie daran anknüpfend die Rolle und Funktion der Akkreditierung – und somit verschiedene Bausteine der QI – adressiert. T2 - Mitgliederexklusives Webinar CY - Online meeting DA - 15.10.2020 KW - Management Systeme KW - QI-FoKuS KW - ISO 9001 KW - ISO/IEC 27001 KW - Zertifizierung KW - Kundenaudit KW - Konformitätsbewertung KW - Akkreditierung PY - 2020 AN - OPUS4-51431 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Usmani, Shirin M. A1 - Plarre, Rüdiger A1 - Hübert, Thomas A1 - Kemnitz, E. ED - Richter, K. ED - Van de Kulien, J.-W. T1 - Termite resistance of pine wood treated with nano metal fluorides N2 - Fluorides are well-known as wood preservatives. One of the limitations of fluoride-based wood preservatives is their high leachability. Alternative to current fluoride salts such as NaF used in wood protection are low water-soluble fluorides. However, impregnation of low water-soluble fluorides into wood poses a challenge. To address this challenge, low water-soluble fluorides like calcium fluoride (CaF2) and magnesium fluoride (MgF2) were synthesized as nanoparticles via the fluorolytic sol−gel synthesis and then impregnated into wood specimens. In this study, the toxicity of nano metal fluorides was assessed by termite mortality, mass loss and visual analysis of treated specimens after eight weeks of exposure to termites, Coptotermes formosanus. Nano metal fluorides with sol concentrations of 0.5 M and higher were found to be effective against termites resulting in 100% termite mortality and significantly inhibited termite feeding. Among the formulations tested, the least damage was found for specimens treated with combinations of CaF2 and MgF2 with an average mass loss less than 1% and visual rating of “1”. These results demonstrate the efficacy of low water-soluble nano metal fluorides to protect wood from termite attack. KW - Holzschutzmittel KW - Nanoparticles KW - Fluorides KW - Termites PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-514325 DO - https://doi.org/10.1007/s00107-020-01522-z VL - 78 SP - 493 EP - 499 PB - Springer CY - Berlin AN - OPUS4-51432 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dittmann, Daniel T1 - Aktivkohlecharakterisierung von GAK-Filtern bei unterschiedlichen Laufzeiten N2 - Eine umfangreich ausgestaltete Trinkwasseraufbereitung als Multibarrieren-System ist notwendig, wenn das Rohwasser direkt aus Fließgewässern entnommen wird (z. B. für das Mülheimer Verfahren). Eine der Barrieren wird, als gezielte Behandlungs- oder Sicherheitsstufe, oft als Filter mit granulierter Aktivkohle (GAK-Filter) realisiert. Ihre Standzeit kann bei geringer Wasserbelastung (DOC < 2 mg/L), z. B. bei der Landeswasserversorgung Langenau, bis zu 5 Jahre betragen. Bei Rohwasser mit höherem Organikgehalt (DOC > 7 mg/L), wie bei der Nordwasser in Rostock, wird hingegen mindestens alle drei Jahre die GAK in den Filterkolonnen ausgetauscht. Die Rest-Adsorptionskapazität der GAK kann durch verschiedene Verfahren abgeschätzt werden, ist aber nach wie vor Gegenstand aktueller Forschung. Die weitergehende Charakterisierung der beladenen GAK kann hierbei helfen. Auf dem Poster sollen erste Ergebnisse zu den in Langenau und Rostock eingesetzten Aktivkohlen präsentiert werden. Hierzu wurden die frischen und nach unterschiedlichen Laufzeiten beladenen GAK untersucht. Die Zusammensetzung der Anorganik und der adsorbierten Organik, welche mittels Zersetzungs¬gasanalyse charakterisiert wurde, zeigt deutliche Unterschiede. Bspw. nimmt der Calcium-Gehalt der GAK in Langenau kontinuierlich zu, wohingegen dieser in den Proben aus Rostock mit zunehmender Laufzeit zurückgeht. Umgekehrt verhält es sich mit der Organik: Die GAK aus Rostock zeigen Hinweise auf biologische Besiedelung, während diese in Langenau trotz längerer Filterlaufzeit auszubleiben scheint. T2 - 4. Mülheimer Wasseranalytisches Seminar (MWAS2020) CY - Mülheim an der Ruhr, Germany DA - 16.09.2020 KW - Thermogravimetrie KW - Trinkwasser KW - Wasseraufbereitung KW - Aktivkohle PY - 2020 AN - OPUS4-51433 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmann, Daniel A1 - Lucke, T. A1 - Ruhl, A. S. A1 - Winzenbacher, R. A1 - Jekel, M. A1 - Braun, Ulrike T1 - Untersuchungen zu biologischen, organischen und anorganischen Veränderungen granulierter Aktivkohlen während der Trinkwasseraufbereitung N2 - Untersuchungen zu biologischen, organischen und anorganischen Veränderungen granulierter Aktivkohlen während der Trinkwasseraufbereitung des Landeswasserversorgers Langenau. KW - Thermogravimetrie KW - Trinkwasser KW - Wasseraufbereitung KW - Aktivkohle PY - 2020 SN - 0083-6915 VL - 118 IS - 2 SP - 47 EP - 50 PB - Wiley-VCH Verlag GmbH & Co. KGaA AN - OPUS4-51434 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - Adhesion of Coatings vs. Strength of Composite Materials – A Review of Applications Evaluated by Centrifugal Adhesion Testing (CAT) N2 - Sufficient adhesion/tensile strength are basic requirements for any coating/composite material. For coatings, adhesive strength in N/mm2 is of Major interest for various applications such as decorative and water-repellent coatings on wood (paints and varnishes), optical coatings on glass and polymers (reflectors and filters), electrical coatings on semiconductors, glass and polymers (conducting and bondable layers), mechanical coatings on metals and polymers (wear-reduction, scratch-resistance) and adhesion-promoting layers. For composite materials, tensile strength in N/mm2 is also a key quantity for carbon fiber reinforced composites (CFC), laminates and adhesive-bonded joints. Centrifugal adhesion testing (CAT) transfers the single-sample tensile test from a tensile or universal testing machine into an analytical centrifuge as multiple-sample test of up to eight test pieces. The one-sided sample support instead of a two-sided sample clamping and the absence of mounting- and testing-correlated shear forces provides fast and reliable results both for adhesive strength and bonding strength by means of bonded test stamps. For bonding strength, the evaluation of failure pattern from microscopic inspection is required in order to determine the failure pattern according to ISO 10365 such as adhesive failure (AF), delamination failure (DF) and cohesive failure (CF). Hence, one test run by CAT-technology provides either statistics or ranking of up to eight samples at once. For adhesive strength of coatings, a variety of examples is discussed such as ALD-Al203 layers as adhesion promoters, evaporated Ag-layers on N-BK7 glass, sputtered Cr- and Al-layers on Borofloat 33 glass, evaporated Au-films on N-BK7 glass and sputtered SiO2 -layers on CR39 Polymer. Provided adhesive or bonding strength are high enough, the substrate or the joining part may also fail. T2 - Special PSE 2020 CY - Online meeting DA - 07.09.2020 KW - Centrifugal adhesion testing (CAT) KW - Adhesive strength KW - Pull-off test KW - Failure pattern KW - Compound strength PY - 2020 AN - OPUS4-51231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -