TY - JOUR A1 - Vahlsing, Thorsten A1 - Delbeck, S. A1 - Leonhardt, S. A1 - Heise, H.M. T1 - Noninvasive monitoring of blood glucose using color-coded photoplethysmographic images of the illuminated fingertip within the visible and near-infrared range: Opportunities and questions N2 - Noninvasive blood glucose assays have been promised for many years and various molecular spectroscopy-based methods of skin are candidates for achieving this goal. Due to the small spectral signatures of the glucose used for direct physical detection, moreover hidden among a largely variable background, broad spectral intervals are usually required to provide the mandatory analytical selectivity, but no such device has so far reached the accuracy that is required for self-monitoring of blood glucose (SMBG). A recently presented device as described in this journal, based on photoplethysmographic fingertip images for measuring glucose in a nonspecific indirect manner, is especially evaluated for providing reliable blood glucose concentration predictions. KW - Color sensing KW - Noninvasive glucose sensing KW - Plethysmographic skin imaging KW - Skin tissue spectroscopy KW - Visible/near-infrared spectroscopy PY - 2018 DO - https://doi.org/10.1177/1932296818798347 SN - 1932-2968 VL - 12 IS - 6 SP - 1169 EP - 1177 PB - Sage Publishing AN - OPUS4-46715 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, Christian A1 - Scholz, Philipp A1 - Ulbricht, Alexander A1 - Joshi, Yogita A1 - Weidner, Steffen T1 - Synchrotron based absorption edge tomography for the analysis of 3D printed polymer MOF N2 - Absorption edge tomography is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. The beamline BAM line at BESSY II, which is operated by the Federal Institute for Materials Research and Testing, can provide a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%. Together with the microtomography setup, this enables differential tomography sensitive to any element with N >= 24 (Cr) by using an appropriate K- or L-edge in this range. Here, a polymer filament embedding metal organic framework (MOF) was prepared and used for 3D printing. Absorption edge tomography at the copper K edge was employed to perform a non-destructive 3D characterization of the microstructure of the embedded MOF. Data fusion was then used to determine the size distribution of the embedded MOF. T2 - iCT 2019 CY - Padua, Italy DA - 12.02.2019 KW - Synchrotron tomography KW - BAMline KW - MOF KW - Absorption edge tomography PY - 2019 AN - OPUS4-47391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, Christian A1 - Scholz, Philipp A1 - Ulbricht, Alexander A1 - Joshi, Yogita A1 - Weidner, Steffen T1 - Synchrotron based absorption edge tomography for the analysis of 3D printed polymer MOF N2 - Absorption edge tomography is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. The beamline BAM line at BESSY II, which is operated by the Federal Institute for Materials Research and Testing, can provide a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%. Together with the microtomography setup, this enables differential tomography sensitive to any element with N >= 24 (Cr) by using an appropriate K- or L-edge in this range. Here, a polymer filament embedding metal organic framework (MOF) was prepared and used for 3D printing. Absorption edge tomography at the copper K edge was employed to perform a non-destructive 3D characterization of the microstructure of the embedded MOF. Data fusion was then used to determine the size distribution of the embedded MOF. T2 - iCT 2019 CY - Padua, Italy DA - 12.02.2019 KW - Synchrotron tomography KW - BAMline KW - MOF KW - Absorption edge tomography PY - 2019 AN - OPUS4-47392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Lübbehüsen, J. T1 - Computer Tomography used for inspection of critical Zones in AM parts N2 - Overview on CT for AM, starting from the CT principle, the added value of CT in Additive Manufacturing (AM), examples of CT results on AM workpieces and conclusions. T2 - IIW Annual Assembly 2018, joint seminar on AM CY - Bali, Indonesia DA - 15.07.2018 KW - Computed Tomographie KW - Additive Manufacturing KW - Added Value PY - 2018 AN - OPUS4-47357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oesch, Tyler A1 - Weise, Frank A1 - Meinel, Dietmar A1 - Gollwitzer, Christian T1 - Quantitative in-situ analysis of water transport in concrete completed using X-ray computed tomography N2 - This paper describes a novel methodology for quantitative in-situ moisture measurement without tracking agents using X-ray computed tomography (XCT). The high levels of grey-scale precision required for the measurement of moisture without tracking agents resulted in the need for an additional image calibration procedure to correct for water-related X-ray scattering and for equipment-variability related artefacts arising during in-situ testing. This calibration procedure was developed on the basis of existing principles of XCT image cor-rection. Resulting images of moisture distribution exhibit a high level of agreement with expected material behaviour. This research demonstrated that XCT can be successfully used to measure both moisture-front movement over time and changes in 3D moisture distribution within samples. This approach to moisture measurement lays the groundwork for the planned future investigation of the interaction between cracking induced by varying chemical and mechanical processes and water transport in concrete. KW - X-ray computed tomography (XCT) KW - In-situ testing KW - Water transport KW - Quantitative moisture measurement KW - Concrete PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-474395 DO - https://doi.org/10.1007/s11242-018-1197-9 SN - 1573-1634 VL - 127 IS - 2 SP - 371 EP - 389 PB - Springer Netherlands AN - OPUS4-47439 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heckel, Thomas T1 - Is phased array the future in modern ultrasonic rail inspection? N2 - Compared to standard ultrasonic testing methods the application of phased arrays offers advantages and flexibility by the electronic steering possibilities to control the transmitted and received sound fields as well as the image based evaluation of the recorded scans. For more than one decade phased array systems have been introduced and used in the railway sector for the inspection of wheelsets in the workshops. Up to the present field applications of phased array systems in rail inspection are rather rare. On the other hand a lot of scientific work on rail testing using phased arrays has been carried out in the recent past. Mechanized ultrasonic rail inspection poses strong challenges e.g. due to the harsh environment, complex flaw types and high inspection speeds. Different tasks have to be carried out by non-destructive testing ranging from manufacturing inspection of thermite welds to in-service inspection for operational induced flaws in the rail head, rail web and rail foot as well as rolling contact fatigue. This work will give an overview and categorization of different present approaches for rail testing using phased array. Phased array systems typically offer digital image based inspection results. This make these systems become the perfect candidates to feed inspection data into a modern big data based workflow, using e.g. cloud computing, signal processing and data fusion for recording, positioning and tracking of flaws and artefacts in rails and to gain additional benefit. Evaluation of promising innovative approaches and solutions for phased array based ultrasonic rail inspection in the frame of “Industry 4.0” will be discussed. T2 - QNDE - Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Burlington, VT, USA DA - 15.07.2018 KW - Rail Inspection Phased Array Ultrasound PY - 2018 AN - OPUS4-47211 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heckel, Thomas A1 - Maierhofer, Christiane A1 - Gaal, Mate A1 - Schadow, Florian A1 - Brackrock, Daniel A1 - Blankschän, Michel A1 - Hosseini, Seyed A1 - Lodeiro, M. A1 - Segur, D. T1 - Comparison of the performance of ultrasonic non-destructive testing methods on inspection of fibre reinforced plastics N2 - In the last twenty years, components made of fibre-reinforced plastic became a prominently used material in safety-relevant structures. Periodic in-service inspection of these structures using reliable non-destructive testing methods became a relevant issue in the field. The goal of the EMRP-funded project VITCEA (Validated Inspection Techniques for Composites in Energy Applications) aims on the evaluation of the performance of various non-destructive testing methods on the inspection of fibre-reinforced plastics. In this talk the results of the comparison of different ultrasonic testing methods will be discussed. There are two challenges for the ultrasonic inspection of fibre-reinforced plastics. Firstly, different material properties of the fibre and the resin cause anisotropic acoustical behaviour of the material. Secondly, the physical layout of fibre layers leads to complex structures of fibre-reinforced plastic parts, and thus to a complex acoustical response. Both result in a reduction of the signal to noise ratio and make interpretation of measurement results rather extensive. During the VITCEA project, the acoustical behaviour of fibre-reinforced plate materials has been simulated. Specimens with artificial flaws for the evaluation of the detection thresholds have been designed and manufactured. Various mechanized ultrasonic testing methods including phased-array sensors, air-coupled transducers, immersion tank testing and contact technique have been evaluated on the specially designed specimen. Laboratory scale tests and a round robin test have been carried out. The probability of detection and the detection thresholds for each method have been estimated. T2 - ECNDT - European Conference on Non-Destructive Testing 2018 CY - Gothenburg, Sweden DA - 11.06.2018 KW - Comparison ndt methods FRP fibre reinforced plastics ultrasound PY - 2018 AN - OPUS4-47213 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heckel, Thomas A1 - Casperson, Ralf A1 - Rühe, Sven A1 - Mook, Gerhard T1 - Signal processing for non-destructive testing of railway tracks N2 - Increased speed, heavier loads, altered material and modern drive systems result in an increasing number of rail flaws. The appearance of these flaws also changes continually due to the rapid change in damage mechanisms of modern rolling stock. Hence, interpretation has become difficult when evaluating non-destructive rail testing results. Due to the changed interplay between detection methods and flaws, the recorded signals may result in unclassified types of rail flaws. Methods for automatic rail inspection (according to defect detection and classification) undergo continual development. Signal processing is a key technology to master the challenge of classification and maintain resolution and detection quality, independent of operation speed. The basic ideas of signal processing, based on the Glassy-Rail-Diagram for classification purposes, are presented herein. Examples for the detection of damages caused by rolling contact fatigue also are given, and synergetic effects of combined evaluation of diverse inspection methods are shown. T2 - QNDE - Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Provo, UT, USA DA - 16.07.2017 KW - Rail KW - Inspection KW - Train KW - Ultrasound KW - Signal KW - Processing PY - 2018 DO - https://doi.org/10.1063/1.5031528 VL - 1949 SP - 030005-1 EP - 030005-7 AN - OPUS4-47217 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beckmann, Jörg A1 - Spranger, Holger A1 - Ewert, Uwe T1 - THz Applications for Non-Destructive Testing N2 - Up to now THz-TDS-systems aren’t considered to be nondestructive testing facilities for large scale industrial applications, despite it was proven that they provide a comprehensive set of quality parameters. A practical approach to bring THz-TDS in addition to already existing testing systems into the industrial mainstream is systematic development of future test procedures and test facilities for dielectrics. For this purpose polyeth-ylene test specimen with introduced artefacts were designed, to evaluate the detection sensitivity of Time of Flight measurements based on dielectrics. SAFT reconstructed tomograms are presented which visualize the sizes and location of artificially introduced flaws. T2 - 2017 Far East NDT New Technology & Application Forum (FENDT) CY - XI'an, China DA - 22.06.2017 KW - THz radiation KW - Dielectric materials KW - Image reconstruction KW - Terahertz synthetic aperture PY - 2018 DO - https://doi.org/10.1109/FENDT.2017.8584511 VL - 12 SP - 272 EP - 276 PB - IEEE Conference Publication CY - USA AN - OPUS4-47220 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe T1 - Image Quality in Industrial Radiology N2 - Overview on Concepts and Methodology used for quality ensurance in industrial radiology. The past, present and future. T2 - General Assembly of Academia NDT International CY - Brescia, Italy DA - 12.10.2018 KW - Image quality KW - Computed radiography (CR) KW - Digital Detector Array (DDA) KW - Film radiography PY - 2018 AN - OPUS4-47347 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Vogel, Justus A1 - Zhang, F. A1 - Long, N.X. A1 - Nguyen, T.P. T1 - Visibility of Image Quality Indicators (IQI) by Human Observers in Digital Radiography in Dependence on Measured MTFs and Noise Power Spectra N2 - Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised. T2 - 12th ECNDT 2018 CY - Gothenburg, Sweden DA - 11.06.2018 KW - Image evaluation KW - Computed radiography (CR) KW - Digital Detector Array (DDA) KW - Detail detection PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-473486 UR - www.ndt.net/?id=22967 SN - 1435-4934 VL - 23 IS - 8 SP - 1 EP - 7 PB - NDT.net CY - Kirchwald AN - OPUS4-47348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Optimum Magnification Factor in Digital Radiography - Selection Criteria and Formulas N2 - The transition from X-ray film to digital detectors in radiography is accompanied by an increase of unsharpness due to the larger inherent digital detector unsharpness in comparison to film. The basic spatial resolution of digital detectors (see EN ISO 17636-2) is used today to describe this unsharpness. The geometrical unsharpness of the radiographic projection of object structures onto the detector plane is determined by the focal spot size of the X-ray tube and the magnification. The focal spot size is measured today (see ASTM E 1165) from pin hole camera exposures or edge unsharpness (see ASTM E 2903). The final image unsharpness is a result of a convolution of the geometrical and inherent detector unsharpness function, divided by the magnification factor of the object onto the detector plane. Different approximations of this convolution result in ASTM E 1000 and ISO 17636-2 in different optimum values for the magnification factor for a given focal spot size of a X—ray tube and the basic spatial resolution of the detector. The higher contrast sensitivity, an advantage of digital radiography, compared to film radiography is furthermore improved when using higher X-ray voltages as used with film and smaller focal spots of the X-ray tubes. This allows a higher distance between object and detector resulting in reduced object scatter in the image. The interactions between all these parameters will be discussed and simple rules for practitioners will be derived in this contribution. T2 - 12th ECNDT 2018 CY - Gothenburg, Sweden DA - 11.06.2018 KW - Digital Radiology KW - Image unsharpness KW - Optimum magnification PY - 2018 AN - OPUS4-47351 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Annual Report of Sub-Commission V-A "Radiography-based weld inspection" N2 - A Summary pf the activities of the IIW sub-commission V-A in 2018 for radiographic weld inspection. T2 - Annual Assembly of IIW CY - Bali, Indonesia DA - 15.07.2018 KW - Radiograpgy KW - Weld Inspection KW - International Institute of Welding PY - 2018 AN - OPUS4-47355 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Stegemann, Robert T1 - Update on Revision of ISO 24497 - NDT - MMM - Technique N2 - Presentation of the final compromise reached in 2018 for revision of ISO 24497, final draft for voting at ISO can be prepared now. T2 - IIW Annual Assembly 2018 CY - Bali, Indonesia DA - 15.07.2018 KW - NDT - Metal Magnetic Memory KW - Revision of ISO 24497 KW - New ISO draft PY - 2018 AN - OPUS4-47356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Munsch, Sarah Mandy A1 - Strangfeld, Christoph A1 - Kruschwitz, Sabine ED - Kärger, J. ED - Heitjans, P. T1 - Determining the pore size distribution in synthetic and building materials using 1D NMR N2 - NMR is gaining increasing interest in civil engineering applications for the use of microstructure characterization as e.g. pore size determination and monitoring of moisture transport in porous materials. In this study, the use of NMR as a tool for pore size characterization was investigated. For our study we used screed and synthetic materials at partial and full saturation. A successful determination could be achieved when having a reference or calibration method, although partly diffusion effects have been registered. Due to these diffusion effects, for the determination of pore size distributions of synthetic materials another NMR device was needed. Finally, the determination of the surface relaxivity of screed (50 μm/s) led to a higher value than first expected from literature. T2 - 14th International Bologna Conference on Magnetic Resonance in Porous Media CY - Gainesville, FL, USA DA - 18.02.2018 KW - NMR relaxometry KW - Pore size distribution KW - Building materials KW - Porous materials KW - Surface relaxivity PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-483680 UR - https://diffusion.uni-leipzig.de/pdf/volume31/diff_fund_31(2019)02.pdf SN - 1862-4138 N1 - Geburtsname von Munsch, Sarah Mandy: Nagel, S. M. - Birth name of Munsch, Sarah Mandy: Nagel, S. M. VL - 31 IS - 2 SP - 1 EP - 9 PB - University of Leipzig CY - Leipzig AN - OPUS4-48368 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lugovtsova, Yevgeniya A1 - Bulling, Jannis A1 - Prager, Jens T1 - Fantastic guided modes and how to find them N2 - Ultrasonic guided waves (UGW) have been shown to be suitable for non-destructive testing (NDT) and structural health monitoring (SHM) of many engineering structures. Development of a technique based on UGWs requires careful understanding obtained through modelling and analysis of wave propagation and mode-damage interaction due to their dispersion and multimodal character. This presentation will provide insights into the Scaled Boundary Finite Element Method and its applicability for tackling wave propagation problems. Features and limitations of the SBFEM will be presented on an example of a multi-layered plate structure consisting of isotropic and anisotropic materials bonded together. You will be guided through the process of picking up the wave modes for your application. Starting from the calculation of dispersion curves and mode shapes to the analysis of wave propagation and mode-damage interaction. The main highlight of the presentation lies in the ability to detect damage in a certain layer depending on the mode used. The resulting deeper understanding of the wave propagation in multi-layered structures is the key to further developments of NDT and SHM for engineering structures consisting of multiple layers. T2 - Von CEA Eingeladener Vortrag CY - Saclay, France DA - 07.06.2019 KW - Structural Health Monitoring KW - Pressure tanks KW - Hydrogen storage KW - Natural gas KW - Composites KW - Scaled Boundary Finite Element Method PY - 2019 AN - OPUS4-48375 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bulletti, A. A1 - Capineri, L. A1 - Lugovtsova, Yevgeniya A1 - Prager, Jens T1 - Charachterization of piezopolymer interdigital transducer's vibrational modes N2 - Lamb waves are widely used for monitoring the health of structures made of laminated materials (metals, composites). Piezoelectric ultrasonic transducers transmit and receive acoustic guided waves that interact with the elastic properties and the defects of the material under test. In recent years, DINFO developed piezopolymer Interdigital Transducers (IDTs) proven to be suitable to build SHM systems for aerospace applications. Their base material is a Cr/Au-coated PVDF-TrFE copolymer sheet, having a thickness of 100μm and a metallization of 0.1μm on both sides. IDTs are attractive for SHM systems for their capability to select specific Lamb wave modes when designed with appropriate electrode pattern. For a reliable application, it is crucial to characterize the in-plane and out-of-plane displacement of the transducer and to correlate the ultrasonic propagating signal with the Lamb waves dispersion curves in laminates. For example, for a 2 mm aluminum plate A0 mode has dominant out-of-plane displacement, whereas S0 mode has dominant in-plane displacement at the plate's surface. In collaboration with BAM the characterization of free vibrational modes using a 3D laser doppler vibrometer was performed. The analysis in the frequency domain was performed using the following parameters: a chirp excitation with frequencies 50-500 kHz and 0.5-1 MHz with 195 Hz and 390 Hz frequency resolution respectively at 100 Vpp for a total of 90 averaged measurements per point. Also propagating modes were characterized by bonding the IDT on a 2 mm aluminum plate and analyzing the in-plane and the out-of-plane components. A0-mode was successfully excited having the main lobe aligned with the main axis of the IDT, confirming the dominant presence of this propagating mode. The results could be used as a basis for design and optimization of the IDTs in terms of directivity and mode selection, and to facilitate interpretation of the ultrasonic guided waves propagating in laminated structures. T2 - 51th Annual Meeting of the Associazione Societa Italiana Di Elettronica CY - Rome, Italy DA - 26.06.2019 KW - Structural Health Monitoring KW - Interdigital Transducer KW - PVDF KW - Ultrasonic guided waves KW - Lamb waves PY - 2019 AN - OPUS4-48382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Virtual CT with Complex scanning trajectories in aRTist N2 - The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiographic process of industrial radiology. In this contribution we focus on virtual computer tomography, the simulation of tomographic scans. The possibilities to simulate complex scanning trajectories are shown in combination with the tomographic reconstruction using individual projection matrices. T2 - The 4th Annual Advances in X-Ray Imaging Workshop CY - Diamond Light Source, Didcot, UK DA - 11.06.2019 KW - X-ray Computer-tomography simulation PY - 2019 AN - OPUS4-48297 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Waske, Anja A1 - Ewert, U. A1 - Bircher, B. A1 - Korpelainen, V. A1 - Costin, M. A1 - Yang, F. A1 - Hörauf, F. A1 - Steffen, J. P. A1 - Dai, G. A1 - Deresch, A. A1 - Graf vom Hagen, C. T1 - EMPIR Project NanoXSpot N2 - The overall objective of project NanoXSpot (Nanometre X-ray Focal Spot Measurement) is to develop traceable measurement methods for determining the focal spot size, shape, and position of nanometre resolution X-ray tubes. The impact of the technical results will be ensured by preparing prenormative documents for submission to CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing), which directly addresses the research needs of CEN, currently revising standards in the series 12543 for focal spot measurements below 5 µm spot size to harmonise standards and measurement method between ASTM and CEN. T2 - DACH-Tagung CY - Friedrichshafen, Germany DA - 27.05.2019 KW - Standardization KW - X-Ray tube KW - Focal spot measurement PY - 2019 AN - OPUS4-48298 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vahlsing, Thorsten A1 - Raum, Hanne A1 - Casperson, Ralf A1 - Pohl, Rainer A1 - Heckel, Thomas A1 - Beilken, D. A1 - Dilz, K. A1 - Rühe, S. T1 - FE-simulation of eddy current signals produced from basic model cracks for running surface rail defects N2 - Non-destructive testing for surface crack detection and head check depth quantification at the gauge corner of railway tracks can be achieved using eddy current methods. With the extension of the tested zone to the running surface, rail defect signal types other than head checks can be measured. Due to their mostly irregular shape, a quantitation based on a calibration against regular test cracks of varying depth may not be linear. Estimates of the expected influence of more complex crack patterns may be obtained by a finite element simulation of sufficiently simple limiting cases, like two displaced or intersecting cracks or a simply branched or flexed crack. As a first step, a 3D finite element model of the HC10 eddy current probe distributed by Prüftechnik Linke und Rühe (PLR), Germany was built and verified against measured results from an (easily fabricated) reference block with isolated long cracks. T2 - 15th Railway Engineering Conference CY - Edinburgh, UK DA - 03.07.2019 KW - Finite element analysis KW - Eddy current testing KW - Rail inspection PY - 2019 SP - 1 EP - 11 AN - OPUS4-48529 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -