TY - CONF A1 - Neumann, Patrick P. T1 - Seminar on Smelling Drones – Part 2: Design and Experimental Study of an Nano Aerial Robot for ARO Applications N2 - This seminar series comprises three lectures on drones and ground robots capable of sensing chemical substances and two accompanying hands-on workshops on nano drones equipped with chemical sensors. In the first lecture, Dr. Neumann will talk on a summary of aerial robot olfaction and his research. In the second and third lectures, more details of the nano drones equipped with chemical sensors will be provided, and the participants can get hands on experience of the nano drones in the accompanying workshops. The lectures will be given in English. This seminar series is supported by FY2023 Researcher Exchanges Program in UEC. T2 - Seminar Series on Smelling Drones CY - Tokyo, Japan DA - 28.11.2023 KW - Mobile robotic olfaction KW - Nano aerial robot KW - Gas source localization KW - Setup and Validation KW - Gas distribution mapping PY - 2023 AN - OPUS4-59130 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. T1 - Capabilities of using mobile platforms for monitoring hazard scenarios by the example of the RASEM project N2 - This presentation shows the capabilities of mobile platforms for monitoring hazard scenarios. As an example the RASEM project is presented. Furthermore two ideas for future work are shown, namely, Aerial-based Gas Tomography and Passive Smart Dust. T2 - Climate Change @ Fire Science Workshop CY - Berlin, Germany DA - 10.11.2022 KW - RASEM KW - Dust sensor KW - Low-cost KW - Sensor network KW - Passive Smart Dust KW - Gas Tomography PY - 2022 AN - OPUS4-56296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Drone-Based Localization of Hazardous Chemicals by Passive Smart Dust N2 - Rapid detection and localization of hazardous chemicals is crucial for environmental monitoring, occupational safety, and emergency response. This study presents a novel approach that combines drone technology with passive smart dust – biodegradable, paper-based chemical sensors – to remotely identify and map hazardous substances. In contrast to conventional smart dust concepts based on electronic microsensors with significant limitations in power supply, cost and environmental impact, this method uses cellulose-based, confetti-like sensors impregnated with colorimetric or fluorescent indicators. These sensors change color in response to chemical exposure, enabling simple optical detection from a distance. A drone equipped with a conventional digital camera takes pictures of the deployed sensors, which are then analyzed by automated image processing. The system converts images from the red-green-blue color model (RGB) into hue-saturation-value space (HSV) and applies threshold filters and clustering algorithms to increase the accuracy of identifying hazardous zones. Field tests using thymol blue as a pH-sensitive indicator have successfully demonstrated the system's ability to detect and locate acid spills in an outdoor environment. The results confirmed that low-cost, off-the-shelf drones can effectively monitor affected areas by providing real-time data for responders while minimizing human exposure to hazardous chemicals. This approach offers a fast, scalable, cost-effective and environmentally friendly alternative to conventional hazard detection technologies. Other important advantages are the close proximity of the sensors to the contamination, the avoidance of downwash problems by the drone propellers and the generation of a dense mesh of data points. Since no complex electronic sensors are required and simple, biodegradable materials are used, the system is well suited for large-scale deployment in industrial accidents, environmental pollution and chemical disaster scenarios. Future research will investigate additional chemical indicators to expand detection capabilities, optimize sensor deployment, and refine data processing for greater accuracy. The passive smart dust system represents a new concept in remote chemical hazard monitoring and may have broad implications for accident response, environmental crime, facility security, and attacks with chemical weapons. N2 - Die schnelle Erkennung und Lokalisierung gefährlicher Chemikalien ist für die Umweltüberwachung, den Arbeitsschutz und den Katastrophenschutz von entscheidender Bedeutung. Diese Studie stellt einen neuartigen Ansatz vor, der Drohnen-Technologie mit Passivem Smart Dust – biologisch abbaubaren, papierbasierten chemischen Sensoren – kombiniert, um gefährliche Substanzen aus der Ferne zu identifizieren und zu kartieren. Im Gegensatz zu herkömmlichen Smart-Dust-Konzepten, die auf elektronischen Mikrosensoren mit erheblichen Einschränkungen bei der Stromversorgung, den Kosten und der Umweltbelastung basieren, verwendet diese Methode zellulosebasierte, konfetti-artige Sensoren, die mit kolorimetrischen oder fluoreszierenden Indikatoren imprägniert sind. Diese Sensoren ändern ihre Farbe bei Kontakt mit Chemikalien, sodass eine einfache optische Erkennung aus der Ferne möglich ist. Eine Drohne, die mit einer herkömmlichen Digitalkamera ausgestattet ist, nimmt Bilder der eingesetzten Sensoren auf, die dann durch automatisierte Bildverarbeitung analysiert werden. Das System konvertiert Bilder vom Rot-Grün-Blau-Farbmodell (RGB) in den Farbton-Sättigungs-Wert-Raum (HSV) und wendet Schwellenwertfilter und Clustering-Algorithmen an, um die Genauigkeit bei der Identifizierung gefährlicher Zonen zu erhöhen. Feldtests mit Thymolblau als pH-empfindlichem Indikator haben erfolgreich die Fähigkeit des Systems nachgewiesen, ausgelaufene Säure in Außenbereichen zu erkennen und zu lokalisieren. Die Ergebnisse bestätigen, dass kostengünstige, handelsübliche Drohnen betroffene Bereiche effektiv überwachen können, indem sie Einsatzkräften Echtzeitdaten liefern und gleichzeitig die Exposition von Menschen gegenüber gefährlichen Chemikalien minimieren. Dieser Ansatz bietet eine schnelle, skalierbare, kostengünstige und umweltfreundliche Alternative zu herkömmlichen Technologien zur Gefahrenerkennung. Weitere wichtige Vorteile sind die räumliche Nähe der Sensoren zur Kontamination, die Vermeidung von Abwindproblemen durch die Drohnenpropeller und die Erzeugung eines dichten Netzes von Datenpunkten. Da keine komplexen elektronischen Sensoren erforderlich sind und einfache, biologisch abbaubare Materialien verwendet werden, eignet sich das System gut für den großflächigen Einsatz bei Industrieunfällen, Umweltverschmutzung und chemischen Katastrophenszenarien. In zukünftigen Forschungsarbeiten sollen weitere chemische Indikatoren untersucht werden, um die Erkennungsmöglichkeiten zu erweitern, den Sensoreinsatz zu optimieren und die Datenverarbeitung für eine höhere Genauigkeit zu verfeinern. Das passive Smart-Dust-System stellt ein neues Konzept für die Fernüberwachung chemischer Gefahren dar und könnte weitreichende Auswirkungen auf die Unfallbekämpfung, Umweltkriminalität, Anlagensicherheit und Angriffe mit Chemiewaffen haben. T2 - 39th Session of the Scientific Advisory Board of the OPCW CY - The Hague, Netherlands DA - 01.04.2025 KW - Imaging KW - Remote Sensing KW - Chemosensors KW - Organization for the Prohibition of Chemical Weapons (OPCW) KW - CBRN Defence PY - 2025 AN - OPUS4-62897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Wessen Problem ist Mikroplastik eigentlich? N2 - In den letzten 20 Jahren ist die Aufmerksamkeit vieler Forschender sowie der Politik und der Bürger selbst auf ein wachsendes Kunststoffproblem unserer Zeit stark gestiegen. Mangelnde Wertstoffkonzepte, Sammelstellen und unbedachtes Einbringen von Kunststoffprodukten in die Umwelt führen dort zu einer Anreicherung. Durch äußere Witterungseinflüsse können diese Produkte degradieren und fraktionieren, so dass heute in allen Teilen der Welt Mikroplastik (1-1000 µm, ISO/TR 21960:2020) unterschiedlicher Polymermaterialien nachgewiesen werden kann. Bei Mikroplastik gilt das Vorsorgeprinzip. Die Partikel können weiter zerfallen in Nanoplastik (< 1 µm, ISO/TR 21960:2020). Ob eine toxikologische Gefährdung von Mikro- oder Nanoplastik ausgeht, wird vielfältig untersucht. Bisher stehen valide Ergebnisse aus. Untersuchungen zur Häufigkeit, dem Transport und möglicher Senken und Eintragspfade muss aber Rechenschafft getragen werden, so dass ein Monitoring von Mikroplastik bereits in der Revision der Trinkwasserrahmen-Richtlinie und der Abwasserrahmen-Richtlinie gefordert wird. Bedenklich ist auch die Verordnung über Mindestanforderungen an die Wasserwiederverwendung (2020/741), in welcher nicht verbindlich gesagt wird, Wasser welcher Reinigungsstufe eines Klärwerks auf die Felder zur Wiederverwendung aufgebracht werden darf. Einer Regulierung über die EU-Plastikstrategie hinaus mit z.B. Verboten für Einwegplastik-Produkte und Rezyklingquoten kann nur entgegengewirkt werden, wenn valide Messmethoden, Referenzmaterialien und Standards existieren, die das tatsächliche Ausmaß von Mikroplastik-Konzentrationen in Luft, Wasser, Boden und Biota zuverlässig und genau aufzeigen. T2 - Technomer CY - Chemnitz, Germany DA - 06.11.2025 KW - Mikroplastik KW - Referenzmaterial KW - TED-GC/MS PY - 2025 AN - OPUS4-64618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Textile Fibers as Reference Materials for Microplastic Release N2 - Fibers of textile origin are named as high contributor for microplastic pollution in the environment next to e.g. plastics from packaging, tire wear and paints. Small fibers and fragments (microplastics: 1-1000 µm) can be released from textiles by mechanical abrasion during application (e.g. wearing) or washing. To date, the occurrence, transport pathways, and impacts of such small fibers on the environment and human health remain unclear. The European Commission revised the Urban Wastewater Treatment Directive (Directive (EU) 2024/3019) and made monitoring of microplastics mandatory in the next years. Additionally, standards for microplastic detection are developed in the ISO standardization body ISO/TC 147/SC 2 with the documents ISO/DIS 16094-2 and ISO/DIS 16094-3. Detection mainly occurs by thermoanalytical methods for mass or vibrational methods with microscopes for numbers. Such standards and regulatory efforts need validated methods, which themselves need reference materials for validation. Reference materials are well characterized materials that are produced for a specific purpose and are homogeneous and stable within one property of interest. The shape and the composition of the reference particles/fibers will affect the detection, hence it is important to validate the instruments with fibers, if this is the task for monitoring campaigns. This work describes the production of realistic fibers as reference material for microplastic analysis. The individual samples contain of a small number (< 1000) and mass (< 20 µm) of fibres. Homogeneity and stability control occurred by thermogravimetric analysis and µ-Raman. Further characteristics were determined for type, shape and size distribution. T2 - TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Reference materials KW - Microfibers KW - Microfiber release PY - 2025 AN - OPUS4-64620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Production of small micro- and nanoplastic reference materials supporting harmonization and standardization N2 - The MICROPLASTICdays at Ljubliana, Slowenia, were organized in cooperation with the PRIORITY cost action. The topic has been reference materials this time. The talk gives an idea of the preparation of reference materials in micro- and nanoplastic topic to support standardisation and regulation. It defines the term of micro-and nanoplastics and presents different case studies and critical attributes to the production depending on the enduser needs. T2 - MICROPLASTICdays CY - Ljubljana, Slovenia DA - 25.03.2025 KW - Microplastics KW - Nanoplastics KW - Reference materials PY - 2025 AN - OPUS4-62801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - PE-Rezyklat Einsatz in Gefahrgutbehältern? N2 - In diesem Vortrag geht es darum zu beschreiben, ob Rezyklat für PE Behälter gefüllt mit Gefahrgut Anwendung finden darf. Kanister aus Neuware und Rezyklat wurden verschiedenen Untersuchungen unterzogen. Es wurde der Feststoff und Leachable getestet. Methoden sind TED-GC/MS und GC-HRMS. Proben der Leachable wurden nach 1 und 4 Wochen genommen und die Peakanzahl vergleichen dargestellt. Als Lösemittel wurden Wasser, Ethanol, EtOAc, Ammoniak und HNO3 verwendet. T2 - Fachaustausch Projekt GeSKAR CY - Dessau, Germany DA - 10.01.2025 KW - Gefahrgutbehälter KW - Rezyklat PY - 2025 AN - OPUS4-62396 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kittner, Maria T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis N2 - Es handelt sich hierbei um die Abschluss-Präsentation des Projektes "Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis", die am 28.11.24 vor dem Drittmittelgeber Zukunft Bau Forschungsförderung im Rahmen der 28. Projekttage der Bauforschung präsentiert wurde. Der 30-minütige Vortrag gliederte sich in die Kapitel Forschungsbedarf, Konzept, Ergebnisse und Take Home-Messages des Projektes. T2 - 28. Projekttage der Zukunft Bau Forschungsförderung CY - Online meeting DA - 26.11.2024 KW - Mikroplastik KW - TED-GC/MS KW - Kunststoffrasen KW - PAK KW - Schwermetalle KW - Mikroplastik Eluat Lysimeter PY - 2024 AN - OPUS4-61815 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Cirkovic Velickovic, T. A1 - Altmann, Korinna A1 - Dailey, L T1 - CUSP Conference WG1 & WG3: MATERIALS AND METHODS N2 - This talk is a presentation about the main results of the CUSP cluster on micro- and nanoplastics human health that work from 2021 to 2025 in Horizon Europe programme according to the WG1 and 3. These groups combined the analytics and the materials with interlaboratory comparisons (ILC). The talk reflects the need of realistic test materials with defined properties for micro- and nanoplastic research. Some were developed are now available. The talk also highlights the need for harmonisation and the results of different ILCs that were performed. T2 - CUSP conference CY - Brussels, Belgium DA - 25.02.2025 KW - Microplastics KW - Reference materials KW - Interlaboratory comparison (ILC) PY - 2025 AN - OPUS4-62703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kittner, Maria T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis N2 - Projektvorstellung "Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis": Motivation, Konzept, Umsetzung, erste analytische Ergebnisse der TED-GC/MS T2 - 24. Projekttage der Zukunft Bau Forschungsförderung CY - Bonn, Germany DA - 13.06.2023 KW - Mikroplastik KW - TED-GC/MS KW - Kunststoffrasen KW - Lysimeter KW - Beschleunigte Alterung PY - 2023 AN - OPUS4-58441 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kittner, Maria T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis N2 - Projektvorstellung "Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis": Konzept, Umsetzung, erste Mikroplastik-Ergebnisse. T2 - Projektbegleitkreissitzung des Projektes "Ermittlung und Minderung von Mikroplastik- und Schadstoffemissionen von Kunststoffrasen-Sportplätzen (MiMiK)“ CY - Sittensen, Germany DA - 25.09.2023 KW - Mikroplastik KW - TED-GC/MS KW - Kunststoffrasen KW - Lysimeter KW - Beschleunigte Alterung PY - 2023 AN - OPUS4-58442 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Herzel, Hannes T1 - Thermochemische P-Rückgewinnungsverfahren in Deutschland zur Düngerproduktion N2 - Die Firma Emter GmbH betreibt die Klärschlammverbrennungsanlage Altenstadt und hat in die bestehende Monoverbrennung einen thermochemischen Prozess integriert, um hochwirksame und schadstoffarme Düngemittel aus Klärschlamm herzustellen. Die Anlage ist aktuell die größte Phosphorrecyclinganlage in Deutschland mit der die Vorgaben der AbfKlärV bereits frühzeitig umgesetzt werden. Das Projekt R-Rhenania begleitet die Phosphorrecyclinganlage mit Untersuchungen zur Produktqualität, mit Gefäßversuchen und Feldversuchen im ökologischen Landbau, mit Ökobilanzierung und der Konfektionierung verschiedener Düngemittelprodukte. Viele Klärschlammaschen haben geringe Schwermetallgehalte und sind geeignet durch vergleiche thermochemische Prozesse behandelt zu werden. Mit den Daten aus dem Klärschlammasche-Monitoring der BAM können die Potentiale für die Verwertung der Aschen in den thermochemischen Prozessen wie AshDec oder CaNaPhos abgeschätzt werden. T2 - DWA Klärschlammnetzwerk Nord-Ost CY - Berlin, Germany DA - 21.01.2026 KW - Phosphor KW - Recycling KW - Thermochemisch KW - Großtechnik PY - 2026 AN - OPUS4-65611 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schlegel, Moritz-Caspar T1 - Die Ökodesign-Rahmenverordnung - Produkteffizienz neu gedacht N2 - Die Präsentation fasst das europäische Verständnis für den Begriff "Produkteffizienz" und die diesbezügliche Entwicklungen der vergangenen Jahre zusammen. Es wird eine Verbindung zwischen Rechtssetzung, Normung und Forschung hergestellt und entsprechende Beiträge zur der Transformation von einer linearen- zu einer zirkulären Wirtschaft (Circular Economy) erörtert. T2 - DIN-Mitgliederdialog CY - Berlin, Germany DA - 03.03.2026 KW - Circular economy KW - Product efficiency KW - Normung KW - Ecodesign KW - Policymaking PY - 2026 AN - OPUS4-65631 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, Paul T1 - Microanalysis of Airborne Nano/Microplastic Particles in an Textile Industrial Environment N2 - Micro- and nanoplastics (MNPs) are emerging global contaminants, present in air, soil, and water. The textile industry is potentially a major contributor, releasing synthetic particles like polyamide, polyester, and acrylic during production. This study assessed MNP levels outside and inside a textile-processing facility using online air samplers with silicon (Si) and quartz filters. Real-time particle counts (PM0.3–PM10) were obtained via a laser detector. Si filters (9 mm, 10/1 µm pores) and quartz filters (25 mm, 1.2 µm pores, pre-calcined at 800°C) were used for sampling. Custom holders allowed selective sampling for PM10 and PM1 on Si filters. Sampling conditions included a 3-hour collection at 2 L/min (GilAir Plus pump) starting at 7:00 AM (T1) and 2:00 PM (T2), with intermittent ventilation, 23.3 °C average temperature, and 52.5% humidity. Particle weights collected (µg) were: quartz – 4.9E-05 (T1), 5.1E-05 (T2); Si – 3.2E-05 (T1), 5E-06 (T2). Outside particle counts ranged from 3,584 (T1) to 15,165 (T2); inside: 9,901 (T1) to 12,921 (T2). Maximum indoor PM10 and PM0.3 levels were 72/m³ and 71,979/m³, respectively. Particles were analyzed using electron microscopy and µRaman spectroscopy, confirming high concentrations of irregularly shaped PP-based particles (1–5 µm). T2 - 12th TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Airborne particles KW - Raman microspectroscopy PY - 2025 AN - OPUS4-64485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Validation of microplastics detection methods and proficiency testing: Suitable microplastic reference materials for interlaboratory comparison N2 - The talk summarizes challenges in microplastic analysis. It shows the preparation of microplastic reference materials as well as the testing on homogeneity and stability. The reference material is used in an international laboratory comparison to compare different detection methods used for microplastic analysis. The methods used were µ-IR (FTIR+LDIR) for number-based methods and TED-GC/MS and Py-GC/MS for mass-based methods. The ILC was done under the umbrella of VAMAS TWA 45. Results of the participants are presented. T2 - BAM Akademie CY - Online meeting DA - 16.05.2024 KW - Microplastics KW - Reference materials KW - ILC KW - Microplastics detection KW - TED-GC/MS KW - Polymer 3R PY - 2024 AN - OPUS4-60085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik Detektion mit Thermoanalytischen Methoden: Analytik, Referenzmaterial, Ringversuche N2 - Ich dem Vortrag geht es um die Vorstellung von thermoanalytischen Methoden für die Mikroplastik-Detektion. Verschiedene Kopplungsmöglichkeiten werden gezeigt und die Funktionsweise der TED-GC/MS wird erklärt. Im zweiten Teil werden Referenzmaterialien für die Mikroplastik-Analytik diskutiert. PET -Tabletten des PlasticTrace Projektes werden vorgestellt. Am Ende wird der VAMAS Ringversuch zur Mikroplastik-Detektion gezeigt. T2 - Plastik, Mikroplastik, Nanopartikel, PFAS und Verunreinigungen (Agilent Workshop) CY - Hamburg, Germany DA - 28.05.2024 KW - Mikroplastik KW - TED-GC/MS KW - Polymer 3R KW - Ringversuche KW - Referenzmaterial PY - 2024 AN - OPUS4-60155 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogel, Christian T1 - Investigating the Thermal Decomposition of PFAS in a Full-Scale Commercial Hazardous Waste Incinerator (SERDP ER24-4073) N2 - Effective and safe treatment of per- and polyfluoroalkyl substances (PFAS)-laden waste in full-scale hazardous waste facilities is currently the only commercial method for large-scale PFAS destruction, but concerns remain about incomplete combustion and harmful byproducts. Therefore, the fate of fluorine during incineration was investigated in a full-scale hazardous waste incinerator to assess the viability and potential risks of this method. The project involves developing advanced analytical tools, including real-time infrared spectroscopy, and conducting trial burns under varied conditions. Conditions that influence incineration performance are identified, analyzing for products of incomplete destruction (PIDs), exploring the role of fly ash and surfaces in PFAS breakdown, and evaluating the potential formation of polyfluorinated dioxins and furans. Collectively, these tasks aim to deliver practical tools and guidance for scientists and engineers, while informing policymakers and the public on the benefits and potential risks of PFAS incineration. T2 - DoW Applied Innovation Workshop CY - Washington, DC, USA DA - 02.03.2026 KW - Per- and polyfluoroalkyl substances (PFAS) KW - Incineration PY - 2026 AN - OPUS4-65639 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Mikroplastik heute: Was haben wir in den letzten Jahren erreicht? N2 - In diesem Vortrag geht es um eine Übersicht über die Thematik der Mikroplastik, Was ist Mikroplastik, wie entsteht es und wo kommt es her. Es wird beschrieben wie eine repräsentative Probenahme erfolgen kann und wie welche Herausforderungen bei der Probenvorbereitung existieren. Die Detektion wird ausführlich beschrieben, sowohl mit Partikelanzahl als auch Masse. Im weiteren werden erste Referenzmaterialien und ihre Anwendung in internationalen Ringversuchen beschrieben. Der zweite Teil zeigt die Normungsaktivitäten im Bereich der Mikroplastik. T2 - Mitgliederversammlung der GdCh Lackchemie CY - Online Meeting DA - 20.09.2024 KW - Mikroplastik KW - TED-GC/MS KW - Polymer 3R KW - Reference material KW - ILC on detection methods PY - 2024 AN - OPUS4-61087 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Miclea, Paul-Tiberiu T1 - Membrane filter cascade for size-selective analysis of nano-and micro particles N2 - From a metrological point of view, the analysis of micro and nanoplastics MNP requires not only representative and meaningful methods for sampling, preparation, and detection, but also defined and reproducible analytical procedures for the processes and materials used. For such a validation of the detection procedures (including the determination of process and laboratory blank values), the filters and laboratory conditions used in interaction with the final MNP measurement play a central role for detection limits regarding MNP size, MNP content and statistical measurement control, in addition to the reference materials mentioned above. On the basis of available filtration materials (e.g. metal mesh, silicon, aluminum oxide, polycarbonate) and metrological boundary conditions, key aspects for metrologically sound method development must be defined. Two key categories of analysis are developed for the characterization of MNP’s: analytical methods (e.g. µ-IR spectroscopy, µRaman) and mass spectrometry (eg. Py-GC/MS or TED-GC/MS). If in the first category the shape, size, number of particles and the size distribution present in the samples can be determined. In the second category the mass of the material can be measured and the volume of plastic present in the samples can be deduced from this. Both catagories are very sensitive in terms of the volume of material that can be analyzed; vibrational methods can detect single particles but mass-based method require enough particles to reach the limit of detection. That is why in this study we propose a filtration system, which in our opinion brings the two categories much closer to each other and allows true measurements of particle number and mass of the same sample. In this way it is possible not only to estimate the volume of plastic in the sample, but also to determine with much greater precision the number of particles and the type of plastic present. Furthermore, new methods for particle detection can be added and combined with existing methods. Our proposed system can be used for a single filter, but also for the use of several filters in cascade. In this way a separation of particles by size can be achieved. T2 - 13th Annual World Congress of Nano Science & Technology 2024 CY - Osaka, Japan DA - 22.05.2024 KW - Microplastics KW - Si filters KW - Filtration KW - Polymer 3R PY - 2024 AN - OPUS4-61097 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Round Table for Expert Stakeholders​ - The Transfer of Research into Policy and Regulation N2 - This talk gives an overwiew about the material and physico chemical characterisation of materials developed for the EU founded project PlasticsFate. Particles in 1st and 2nd sample set are presented next to their characterisatin and documentation in data sheets. Some materials are prepared for reference material and used in an interlaboratory comparison. Results are briefly discussed. T2 - Stakeholder Workshop PlasticsFate CY - Bühl, Germany DA - 17.09.2024 KW - Microplastics KW - Reference materials KW - Polymer 3R KW - Interlaboratory comparison PY - 2024 AN - OPUS4-61088 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - 70 years size exclusion chromatography - An ongoing challenge N2 - The reason for our current activities is that polymers may also be subject to REACh regulations in the future. In this context, the determination of oligomer content is important. SEC is still the method of choice for determining molar mass distribution. The regulations aim for narrow limits and SEC has rather large error margins, which are well known to all experts. Different polymers need different methods. What to do when samples with a wide range of practical aspects, samples with higher distribution range, reduced solubility, including side components, gel content etc. need be analyzed? A concept for round robin tests and first impressions will be presented. T2 - Analytical Solutions 2025 CY - Ede, Netherlands DA - 04.06.2025 KW - Polymers KW - Size exclusion chromatography KW - REACH KW - Round Robin Tests PY - 2025 AN - OPUS4-63310 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -