TY - GEN A1 - Müller, Simon T1 - FireSpread_MedEU N2 - Wildfires are becoming more frequent and severe under the influence of climate change, posing increasing risks to ecosystems, human health, and infrastructure. Accurate spatiotemporal data on wildfire propagation is essential for advancing fire behavior modeling, improving management strategies, and mitigating future impacts. However, existing datasets with both high spatial and temporal resolution are rare, costly, and time-consuming to produce. To address this gap, we present FireSpread_MedEU, a dataset comprising 313 consecutive burned area maps from 102 wildfire events across the Mediterranean and Europe between 2017 and 2023. Burned areas were derived from high-resolution Planet optical satellite imagery (~3 m spatial, mostly daily temporal resolution) using a semi-automated workflow, followed by manual refinement to ensure highest accuracy. Each dataset entry is enriched with detailed metadata and a subjective quality assessment. With its high level of spatiotemporal precision, FireSpread_MedEU provides essential data for the development and validation of machine learning models or wildfire simulation models. It opens new research opportunities in wildfire behavior analysis, risk assessment, and predictive modeling. KW - Wildfire KW - Spread KW - Machine Learning PY - 2025 DO - https://doi.org/10.5281/zenodo.16813435 PB - Zenodo CY - Geneva AN - OPUS4-64768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Festag, Sebastian A1 - Esser, Jonas A1 - Maiworm, Björn A1 - Hofmann-Böllinghaus, Anja T1 - Herausforderungen des modernen Holzbaus: Erste statistische Erkenntnisse aus realen Gebäudebränden in Holzbauweise N2 - Hinsichtlich des Brandschutzes zeigt der durch die Bundesregierung geförderte Holzbau Herausforderungen gegenüber Massivbauweisen. Diese spiegeln sich in Erfahrungen von Feuerwehren wider, aber nun auch in statistischen Untersuchungen der Brandschadenstatistik der Vereinigung zur Förderung des deutschen Brandschutzes sowie der Arbeitsgemeinschaft der Leiterinnen und Leiter der Berufsfeuerwehren (AGBF) und des Deutschen Feuerwehrverbands (DFV). Im Zeitraum von 2013 bis 2017 wurden in der vfdb-Brandschadenstatistik Daten zu 5016 Alarmierungen bei Gebäudebränden in Deutschland systematisch mit einem einheitlichen Erfassungsbogen erfasst und seit 2016 „bemerkenswerte Brandeinsätze“ durch einen Evaluierungsbogen zu Maßnahmen des vorbeugenden Brand- und Gefahrenschutzes von AGBF/DFV. Grundlage des vorliegenden Beitrags sind die Auswertung und der Vergleich beider statistischer Datensätze hinsichtlich der Brände in Gebäuden in Holzbauweise. Es zeigt sich, dass der Holzbau mit brandschutztechnischen Herausforderungen verbunden ist. KW - Brandschutz KW - Brandstatistik PY - 2025 DO - https://doi.org/10.1002/bate.202400078 SN - 1437-0999 VL - 2025 IS - 102 SP - 1 EP - 8 PB - Wiley AN - OPUS4-63000 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klippel, A. A1 - Hofmann-Böllinghaus, Anja A1 - Gnutzmann, Tanja A1 - Piechnik, K. T1 - Reaction-to-fire testing of bus interior materials: Assessing burning behaviour and smoke gas toxicity N2 - Although fire safety regulations for buses have been adapted in recent years regarding, for example, fire detection and engine fire suppression systems, the changes in regulations for bus interior materials are minimal. A comparison of fire safety regulations for interior materials in other transport sectors for trains, ships or aircraft reveals a much lower level of requirements for bus materials. Although repeated bus accidents as well as fire statistics show the danger a bus fire can pose to passengers. In particular, the combination of a fire incident and passengers with reduced mobility led to severe disasters in Germany and other European countries. To enhance the fire safety for passengers, the interior bus materials are crucial as the fire development in the bus cabin determines whether escape and rescue is possible. Against this background, bus interior materials were tested in different fire test scenarios. Measurement of a wide variety of parameters, for example, the mass loss, ignition time, smoke gas composition, heat release rate among others were carried out. Tested materials complied to the newest set of requirements. For this purpose, interior materials and their components had to be identified according to their chemical structure. Parts of the tests were funded by BASt (Federal Highway Research Institute) in the project 82.0723/2018. Experimental results show reaction-to-fire behaviour which lead to very limited times for escape and rescue in case of fire in a bus cabin. Based on the studies on fire behaviour and toxicity assessment, recommendations for improved fire safety regulations for interior materials could be made. KW - Burning behaviour KW - Bus interior materials KW - Cone calorimeter KW - DIN tube furnace KW - FTIR spectroscopy KW - Reference values KW - Smoke toxicity PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-576085 DO - https://doi.org/10.1002/fam.3108 SN - 1099-1018 VL - 47 IS - 5 SP - 665 EP - 680 PB - Wiley CY - New York, NY AN - OPUS4-57608 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Anderson, Johan A1 - Chiva, Roman A1 - Dumont, Fabien A1 - Lalu, Octavian A1 - Hofmann-Böllinghaus, Anja T1 - Assessment of fire performance of facades in a round robin using the European approach N2 - In recent years, an experimental round robin of full-scale façade tests was conducted using the proposed new European approach for assessing the fire performance of façades. The initial results were used to develop a calibration scheme and to propose assessment criteria aligned with appropriate safety levels. During the project, a need emerged to evaluate the stability of the fire source and the Consistency of heat exposure. This paper addresses these concerns by comparing the mass loss rates across a series of tests and analysing averaged temperature readings at various locations on the façade. The findings indicate that the method demonstrates high stability in terms of mass loss rates and provides consistent and appropriate heat exposure. T2 - Interflam 2025, 16th International Fire Science and Engineering Conference CY - London, UK DA - 30.06.2025 KW - Facade systems KW - Testing PY - 2025 VL - 2025 SP - 562 EP - 572 PB - Interscience CY - London AN - OPUS4-63998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Anderson, J. A1 - Boström, L. A1 - Chiva, R. A1 - Guillaume, E. A1 - Colwell, S. A1 - Hofmann-Böllinghaus, Anja A1 - Toth, P. T1 - European approach to assess the fire performance of façades N2 - Several attempts have been made in the past to develop a European harmonized testing and assessment method for façades before the European commission decided to publish a call for tender on the topic. A project consortium from five countries (Sweden, UK, France, Germany and Hungary) applied to the call for tender and was contracted to develop a European approach to assess the fire performance of façades. 24 sub-contractors and 14 stakeholder entities were part of the project. The objective of the European project was to address a request from the Standing Committee of Construction (SCC) to provide EC Member States regulators with a means to regulate the fire performance of façade systems based on a European Approach agreed by SCC. The initial stages of this Project were focused on establishing a Register of the regulatory requirements in all Member States in relation to the fire Performance of façade systems, and to identify those Member States who have regulatory requirements for the fire performance façade systems which go beyond the current EN 13501 (reaction to fire and fire resistance) classification systems and to collate the details of these additional requirements. After having confirmed the regulatory needs a testing and classification methodology based on BS 8414 and DIN 4102-20 was developed to address the identified key performance and classification characteristics. This paper is a short overview of results the two-year development work, which Final Report published by the European Commission in 2018. KW - Facade KW - Regulation KW - Testing PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530501 DO - https://doi.org/10.1002/fam.2878 SN - 1099-1018 VL - 45(5) IS - Special issue: Facade fire safety SP - 598 EP - 608 PB - Wiley CY - Oxford AN - OPUS4-53050 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hofmann-Böllinghaus, Anja A1 - Klippel, Andrea T1 - Vehicle Fires: Significant Fire Hazard in Transportation Infrastructure N2 - Vehicle fires in transportation infrastructure such as depots, car parks, tunnels and stations are a recurring phenomenon, with recent years witnessing an alarming number of severe incidents, particularly in vehicle depots. These fires often result in the total loss of both vehicles and buildings, with striking similarities in their progression. Analysis of recent fire events, including a study conducted for the German insurer Provinzial, shows that fires in bus depots, military facilities and car parks tend to spread rapidly and destructively. While building regulations vary across sectors and countries, the fire safety standards for interior materials in road vehicles remain globally harmonized and are based on outdated regulations such as FMVSS 302, which offer only a minimal level of protection. In contrast, materials used in trains, ships, and aircrafts must comply with significantly stricter fire safety standards, which may explain the relatively lower incidence of fires in these sectors. Common fire protection systems in depots, such as sprinklers and vents, often fail to account for the specific characteristics of automotive vehicles, including their watertight design and the rapid development of hot gas layers that accelerate fire spread. Insurance companies have begun to acknowledge these challenges. Given the high flammability, heat release and smoke toxicity of materials commonly used in vehicles, combined with the growing share of combustible plastics over the past decades, this paper argues for a paradigm shift. Instead of relying solely on inhancing building protection, introducing significantly stricter fire safety requirements for vehicle materials could offer a more effective and sustainable approach to safeguarding transportation infrastructure. Ongoing experimental investigations are being conducted to evaluate the reaction to fire behavior of various bus interior materials. These studies focus on the emission of toxic gases during combustion, with particular attention to substances exceeding critical AEGL thresholds. Materials such as polyurethane foams and hard plastics have shown significant variation in their smoke gas profiles, highlighting potential health and safety risks in fire scenarios. The research aims to support the development of safer material choices and regulatory measures. Upon completion of tests with additional materials, all findings will be published to ensure transparent and comprehensive reporting. T2 - Interflam 2025, 16th International Fire Science and Engineering Conference CY - London, United Kingdom DA - 30.06.2025 KW - Vehicle fires KW - Transportation PY - 2025 AN - OPUS4-63922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Geoerg, Paul A1 - Schumann, Jette A1 - Holl, Stefan A1 - Holl, Maik A1 - Hofmann-Böllinghaus, Anja T1 - The influence of individual impairments in crowd dynamics N2 - The importance of empirical relations to quantify the movement of pedestrians through a facility has increased during the last decades since performance-based design methods became more common. Bottlenecks are of special interest because of their importance for egress routes and as they result in a reduced capacity. The empirical relations as the density-dependent movement speed or flow rate were derived by studies under laboratory conditions, which were usually conducted with populations of homogeneous characteristics forbetter control of influencing variables. If individual characteristics of a crowd become more heterogeneous, individuals were forced to adapt their individual movement and control individual manoeuvring. These unintended interactions lead to a different shape of the fundamental empirical relations. Here, we present results from a movement study under well-controlled boundary conditions in which participants with and without different characteristics of disabilities participated. To consider the effect of different heterogeneities on the capacity of a facility, fundamental diagrams are generated using the Voronoi method. If participants with visible disabilities (such as using assistive devices) are part of a crowd, significant differences relating to the shape of the empirical Relations and the capacities are found. This indicates that the heterogeneity of a Population leads to an increased interpersonal interaction which results in influenced movement characteristics. KW - Engineering egress data KW - Heterogeneity KW - Human behaviour KW - Movement characteristics KW - Pedestrian dynamics PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-508943 DO - https://doi.org/10.1002/fam.2789 SN - 0308-0501 VL - 45 IS - 4 SP - 529 EP - 542 PB - Wiley Online Libary CY - New Jersey, USA AN - OPUS4-50894 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Piechnik, Kira A1 - Hofmann-Böllinghaus, Anja A1 - Klippel, Andrea T1 - Self‐ignition of forest soil samples demonstrated through hot storage tests N2 - AbstractThe increasing threat of forest fires on a global scale is not only a matter of concern due to the potential harm they may cause to both human and animal life but also due to their significant role in exacerbating climate change. In light of these circumstances, one might inquire as to whether forest soil can self‐ignite and, if so, under what conditions and at what temperatures this phenomenon may occur. This question is being addressed in the German pilot “Fire science of wildfires and safety measures” of the EU project TREEADS, and the first results are presented below. The importance of basic research into the self‐ignition of forest soil cannot be underestimated, as it provides crucial knowledge to prevent forest fires and protect human and animal health. Furthermore, mitigating the occurrence of forest fires can also play a role in reducing greenhouse gas emissions, contributing to global efforts to combat climate change. The procedure of the hot storage test is an effective means of determining whether a material can self‐ignite. During the investigation of six soil samples, it was found that five of them were indeed capable of self‐ignition. In addition to determining whether the material ignites, the modified hot storage test also analyzed the resulting smoke gases and measured their concentration. The research question of whether regional forest soil is capable of self‐ignition can be answered with yes based on these initial tests. Further experiments are needed to determine if self‐ignition causes forest fires. KW - FTIR KW - Hot storage KW - Ignition KW - Soil KW - Wildfire PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-594617 DO - https://doi.org/10.1002/fam.3198 SN - 1099-1018 VL - 48 IS - 4 SP - 495 EP - 507 PB - Wiley CY - New York, NY AN - OPUS4-59461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nandish, Ranjith A1 - Knaust, Christian A1 - Hofmann-Böllinghaus, Anja A1 - Gnutzmann, Tanja A1 - Zehfuß, Jochen T1 - Simulation of wood pyrolysis with component-based mechanism N2 - This paper presents a comprehensive fire simulation study that models the pyrolysis process of beech wood using kinetic parameters with the Fire Dynamics Simulator (FDS). The kinetic methodology is based on the application of these kinetic parameters to govern the underlying pyrolysis reactions. The primary objective was to numerically model the pyrolysis process for beech wood using both single-component (single-step, single reaction scheme) and multi-component (single-step, multi-reaction scheme) kinetic reaction schemes. The accuracy of the numerical model was validated by comparing FDS simulation results with experimental data obtained from thermogravimetric analysis (TGA) and cone calorimeter tests. This approach aids in identifying reliable kinetic reaction input parameters for modelling wood fires. A case study was included to demonstrate the implementation of the kinetic reaction schemes. Numerical results from the TGA simulations for the small-scale pure cellulose test using the single-component approach exhibit consistency with the experimental data. Furthermore, the results demonstrated that the multi-component approach more accurately replicates the shape of the experimental curve for beech wood compared to the single-component approach. However, discrepancies in the tail regions of the curves obtained from the FDS simulations showed the need for further improvement in the modelling approach, particularly regarding the exclusion of char oxidation reactions, which needs to be investigated further. KW - Simulation KW - Wood PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639272 DO - https://doi.org/10.1007/s00231-025-03571-7 SN - 0947-7411 VL - 61 IS - 6 SP - 1 EP - 14 PB - Springer Science and Business Media LLC AN - OPUS4-63927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hofmann-Böllinghaus, Anja A1 - Klippel, Andrea A1 - Gnutzmann, Tanja A1 - Kaudelka, Sven A1 - Rabe, Frederik T1 - Influence of modern plastic furniture on the fire development in fires in homes: large-scale fire tests in living rooms N2 - About 80% of all fire fatalities in Germany occur because of fires in homes. It has been known for some time that modern materials (synonym for materials consisting mostly of synthetic polymers) tend to burn differently from older materials (synonym for materials consisting mostly of fibrous cellulosic substances) and it has been acknowledged that the amount of combustible plastics in homes has increased significantly over the last decades. To investigate the influence of modern furniture and ventilation conditions of fires in homes, a series of four large-scale tests in two Living rooms (LRs) with adjacent rooms (ARs) was performed by BAM and the Frankfurt fire service. Two LRs, one with older furniture and one with modern furniture, were tested twice each. Each test started with the ignition of a paper cushion on an upholstered chair. The influence of modern materials on the fire development was investigated, as well as the influence of the ventilation on the fire development. In all settings, an upholstered chair was the first burning item. Results of the test series show that fires in rooms with modern furniture develop faster than fires in rooms with older furniture. This is true for temperature development in the rooms as well as for smoke production. KW - Room fire KW - Furniture KW - Modern KW - Gas analysis KW - Smoke PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527568 DO - https://doi.org/10.1002/fam.2934 VL - 45 IS - 1 SP - 155 EP - 166 PB - Wiley CY - London AN - OPUS4-52756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Manes, M. A1 - Sauca, A. A1 - El Houssami, M. A1 - Andersson, P. A1 - McIntyre, C. A1 - Campbell, R. A1 - Rush, D. A1 - Hofmann-Böllinghaus, Anja A1 - Wagner, P. A1 - Leene, M. A1 - Oberhagemann, D. A1 - Jomaas, G. A1 - Grone, F. A1 - Guillaume, E. T1 - Closing Data Gaps and Paving the Way for Pan-European Fire Safety Efforts: Part II—Terminology of Fire Statistical Variables N2 - A well-defined terminology of fire-related variables is important for correct analyses and supporting knowledge-based decisions regarding the evaluation of building fires at the European level. After developing an overview of current practices for fire statistics in Part I, the terminology used and the data collected by the EU Member States and eight other countries regarding fire incidents, property damage and human losses were mapped to increase awareness of their practice and support a comprehensive assessment of several fire statistical datasets. A questionnaire was distributed to relevant authorities responsible for the collection, elaboration/analysis, and fire statistical data publications to define and select the essential variables for an appropriate fire assessment and fire incident description. Based on the results of the questionnaire able to identify the essential fire statistical variables and a detailed analysis of current definitions adopted in the fire statistics of the EU Member States and other countries, a common terminology is proposed to collect the necessary data in the EU Member States and obtain meaningful datasets based on standardised terms and definitions. The results will generate essential outputs to move towards harmonised fire statistics at the EU level and contribute to an appropriate analysis able to improve fire prevention and fire mitigation in building fires. KW - Fire statistics PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575725 DO - https://doi.org/10.1007/s10694-023-01408-5 SN - 1572-8099 SP - 1 EP - 32 PB - Springer CY - Heidelberg AN - OPUS4-57572 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hofmann-Böllinghaus, Anja ED - Vogdt, F. U. T1 - Brandschutz N2 - Grundlagen des vorbeugenden baulichen Brandschutzes KW - Brandprüfungen KW - Bauvorschriften PY - 2022 SN - 978-3-8348-2189-8 SP - 199 EP - 220 PB - Springer ET - 1 AN - OPUS4-54317 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR ED - Hofmann-Böllinghaus, Anja ED - Anderson, J. T1 - Special issue: Facade fire safety N2 - Façade fires are of growing concern worldwide. Severe facade fires in different parts of the world as well as activities in many countries regarding the testing of facades show the urgency of the fire safety challenges in façade fires. The need for knowledge and a wide Archive of work in this area has become evident after recent incidents which involved extensive facade fires. These include the tragic fires in Dubai and Grenfell Tower in 2017 in the United Kingdom. In many cases, the widespread live news coverage of the events and size of These fires has emphasized the need for progress in the understanding of the processes involved in these fires and put pressure upon the fire safety engineering community to find effective solutions. KW - Testing KW - Safety PY - 2021 UR - https://onlinelibrary.wiley.com/toc/10991018/2021/45/5 SN - 0308–0501 SN - 1099-1018 VL - 45 IS - 5 SP - 583 EP - 696 PB - Wiley CY - Oxford AN - OPUS4-53102 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Eberwein, Robert T1 - Untersuchung der Gefährdung von Personen und Bauwerken in Folge des Versagens von LNG-Kraftstoffspeichern für Fahrzeuge in Tunneln N2 - Liquefied Natural Gas (LNG) aus regenerativen Quellen, stellt einen potenziellen Kraftstoff für den Schwer- und Fernverkehr des Straßenverkehrs dar. Gegenüber seinen positiven Eigenschaften zu dem in diesem Verkehrssektor häufig verwendeten Kraftstoff Diesel birgt der Kraftstoff aber auch Gefahren für Personen und Bauwerke durch seine sehr niedrige Temperatur bei der Speicherung von ca. -160 °C und seine Explosionsfähigkeit in der Gas-Phase. In der Arbeit wurde sich mit der Gefährdung von Personen und Bauwerken hinsichtlich der von LNG ausgehenden Gefahren in Tunneln auseinandergesetzt. Tunnel stellen besonders schützenswerte Bauwerke dar, da aus vorhergehenden Störfällen in Tunneln bekannt ist, dass diese mit hohen Personen-, Bauwerks-, und Volkswirtschaftlichen-Schäden einhergehen können. Untersuchungsschwerpunkt bei der Bewertung von Gefährdungen durch LNG stellte eine Ereigniskaskade bestehend aus Freisetzung, Verdampfung, Stoffausbreitung und Zündung des sich gebildeten explosionsfähigen LNG-Gas/Luft-Gemisches dar. Mit dem Ziel eine solche Ereigniskaskade realitätsnah vorhersagen und zukünftig hierzu Risikoanalysen durchführen zu können wurden innerhalb der Arbeit Parameterstudien sowie Kalibrierungen und Validierungen gegenüber experimentellen Untersuchungen durchgeführt. Mit den Modellen wurden in der Arbeit exemplarische Fallbeispiele zu Störfällen untersucht. Ergebnisse dieser waren, dass Gefährdungen insbesondere von flüssigem LNG nach dessen Freisetzung und der Verbrennung von LNG-Gas/Luft-Gemischen ausgingen. N2 - Liquefied Natural Gas (LNG) from regenerative sources is a potential fuel for heavy and long-distance road traffic. In contrast to its positive properties compared to diesel, which is often used in this transport sector, the fuel also contains hazards from its very low storage temperature of approx. -160 °C and its explosiveness in the gas phase for personal and structural safety. The dissertation dealt with the dangers to persons and infrastructures according to the hazards by LNG in tunnels. Tunnels are especiallyworth protecting structures since it is known from previous incidents in tunnels that they can go hand in hand with high damage to the people, the structure, and the economy. The main focus of the investigation into the assessment of hazards from LNG was an event cascade consisting of release, evaporation, dispersion, and ignition of the explosive LNG-vapor/air-mixture formed. To realistically predict such an event cascade and being able to carry out risk analyzes for this purpose in the future, parameter studies such as calibrations and validations were carried out concerning experimental investigations. Exemplary case studies on incidents were examined in the thesis with the validated models. The results of this were that there were especially hazards in particular from liquid LNG after its release and the combustion of LNG-vapor/air-mixtures. KW - Verflüssigtes Erdgas KW - Erneuerbare Energien KW - Numerische Strömungsmechanik KW - Sicherheitstechnik KW - Liquefied Natural Gas KW - LNG KW - Renewable fuels KW - CFD KW - Safety engineering PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521145 DO - https://doi.org/10.14279/depositonce-11346 SP - 1 EP - 240 PB - TU Berlin CY - Berlin AN - OPUS4-52114 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Camplese, Davide T1 - Safety assessment of MLI super-insulation systems for cryogenic liquid-hydrogen tanks in fire scenarios N2 - In the context of green energy transition, cryogenic tanks featuring MLI systems are emerging as a leading solution to store hydrogen in heavy-duty vehicles. However, the integrity of such tanks can be jeopardized by fire. In such a scenario, MLI materials degradation can occur, leaving the tank unprotected from the fire heat flux, with consequent rapid pressurization and a high risk of failure. This study presents an assessment of aluminum-based MLI for liquid hydrogen cryogenic tanks under fire exposure based on the estimation of the time to mechanical failure of the equipment. This is calculated through an innovative model that simulates the thermomechanical response of the tank, including the MLI thermal degradation and the pressure-relief valve (PRV) operation. The application to several case studies that consider a typical LH2 tank featuring a wide range of MLI configurations demonstrated the likelihood of failure in case of exposure to a hydrocarbon pool fire, providing also comprehensive insights into the impact of the insulation characteristics and operating conditions on the time to failure. T2 - 18th EFCE International Symposium on Loss Prevention and Safety Promotion in the Process Industries CY - Bologna, Italy DA - 08.06.2025 KW - LH2 KW - Insulation KW - Tanks KW - Fire KW - LNG PY - 2025 AN - OPUS4-63427 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Modelling Fire Response of Cryogenic Liquid Hydrogen Tanks Equipped with Multilayer Insulation (MLI) Systems N2 - In the context of the growing global interest in hydrogen-based green energy, cryogenic tanks equipped with multi-layer insulation (MLI) are emerging as a leading solution for storing hydrogen in vehicles. The integrity of these systems might be threatened during fire exposure. This can trigger the degradation of the MLI materials and induce rapid pressurization of the tank with a high risk of catastrophic failure. In this work, a novel lumped model to simulate the thermal response of MLI-equipped cryogenic liquid hydrogen tanks is presented. The model integrates the accurate database “Coolprop” for hydrogen thermodynamic properties and sub-models for detailed simulation of MLI degradation, providing a realistic simulation of the experimental data obtained under normal operating conditions. The application of the model to several case studies considering different numbers of MLI layers and tank geometries demonstrates that aluminum-based MLI offers scarce protection in case of exposure to a hydrocarbon poolfire. T2 - CISAP 11 CY - Neapel, Italy DA - 15.09.2024 KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Insulation KW - MLI PY - 2024 DO - https://doi.org/10.3303/CET24111076 SN - 2283-9216 VL - 111 SP - 451 EP - 456 PB - AIDIC The Italian Association of Chemical Engineering AN - OPUS4-61384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank ED - Di Benedetto, Almerinda T1 - Experimental Research Of A Tank For A Cryogenic Fluid With A Wall Rupture In A Fire Scenario N2 - In the course of decarbonizing the energy industry, cryogenic energy carriers as liquefied hydrogen (LH2) and liquefied natural gas (LNG) are seen as having great potential. In technical applications, the challenge is to keep these energy carriers cold for a long time. This is achieved in the road transport sector and also stationary applications by thermal super insulations (TSI) which based on double-walled tanks with vacuum and multilayer insulation (MLI) in the interspace. This study focuses on the behaviour of widely used combustible MLI in a fire scenario, at vacuum and atmospheric pressure conditions. The former corresponds to the typical design condition and the latter to the condition after an outer hull rapture of a tank. Furthermore, two fire scenarios were taken into account: a standard-oriented approach and a hydrocarbon fire-oriented approach. For the study, a test rig was applied that allows testing of TSI at industrial conditions and subsequent analysis of TSI samples. The test rig allows thermal loading and performance analysis of TSI samples at the same time. Comparing the tests, the samples degraded differently. However, no sudden failure of the entire MLI was observed in any test. These results are relevant for the evaluation of incidents with tanks for the storage of cryogenic fluids and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures. T2 - 15th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE) CY - Neapel, Italy DA - 10.06.2024 KW - Liquefied hydrogen KW - Liquefied natural gas KW - Cryogenic storage tank KW - Fire KW - Thermal insulation KW - Multi-Layer Insulation PY - 2024 SP - 707 EP - 717 AN - OPUS4-60460 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - A comparative study on insulation materials in tanks for the storage of cryogenic fluids in fire incidents N2 - Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. The focus of this study is to investigate the behavior of different types of TSI when exposed to a heat source that represents a fire. Therefore, a High-Temperature Thermal Vacuum Chamber (HTTVC) was used that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this study, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. The thermal exposure caused different effects on the samples. In practice, this can be connected to the rapid release of flammable gases as well as a Boiling Liquid Expanding Vapour Explosion (BLEVE). These results are relevant for the evaluation of accident scenarios, the improvement of TSI, and the development of emergency measures. T2 - IMECE 2023 CY - New Orleans, Louisiana, USA DA - 29.10.2023 KW - LH2 KW - LNG KW - Fire PY - 2023 SP - 1 EP - 7 AN - OPUS4-58768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Scarponi, Giordano T1 - Performance of MLI systems for LH2 Tanks in fire scenarios N2 - In the course of decarbonizing the energy industry, cryogenic energy carriers are seen as having great potential. This is because they allow significantly higher volumetric energy densities to be achieved than when these energy carriers are stored at typical temperatures on Earth. This is important for numerous energy-intensive applications, such as those found in all transport sectors. Important cryogenic energy carriers include liquefied hydrogen (LH2) and liquefied natural gas (LNG). The challenge is to keep the energy carrier cold for a long time. This is achieved by the implementation of thermal super-insulations (TSI) systems based on multilayer insulations (MLI), microspheres, perlites, and vacuum for instance, and which have proven to be effective in several cryogenic applications. However, due to the short period of use, the low number of documented incidents, and the still few investigations carried out in the field, the exploitation of such systems in the transport sector still suffers from insufficient knowledge about the course and consequences of incidents. Accidents involving collisions, fires, and their combination are quite common in the transportation sector and may generate extraordinary loads on the tank and its insulation system, eventually leading to tank failure. The presentation summarizes the findings from the cooperation of the University of Bologna and BAM regarding the experiments on diverse types of super-insulations with the High Temperature Thermal Vacuum Chamber, as well as the model approaches that were developed to calculate the heat transfer and degradation of MLI’s during high thermal exposure. As an outlook the application of the models, the Cryogenic High Temperature Thermal Vacuum Chamber, and the fire test on HGV-components are presented. T2 - ELVHyS - International Stakeholder's Seminars CY - Bologna, Italy DA - 30.09.2024 KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Fire KW - Safety PY - 2024 AN - OPUS4-61205 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Camplese, Davide T1 - Modelling Fire Response of Cryogenic Liquid Hydrogen Tanks Equipped with Multilayer Insulation (MLI) Systems N2 - In the context of the growing global interest in hydrogen-based green energy, cryogenic tanks equipped with multi-layer insulation (MLI) are emerging as a leading solution for storing hydrogen in vehicles. The integrity of these systems might be threatened during fire exposure. This can trigger the degradation of the MLI materials and induce rapid pressurization of the tank with a high risk of catastrophic failure. In this work, a novel lumped model to simulate the thermal response of MLI-equipped cryogenic liquid hydrogen tanks is presented. The model integrates the accurate database “Coolprop” for hydrogen thermodynamic properties and sub-models for detailed simulation of MLI degradation, providing a realistic simulation of the experimental data obtained under normal operating conditions. The application of the model to several case studies considering different numbers of MLI layers and tank geometries demonstrates that aluminum-based MLI offers scarce protection in case of exposure to a hydrocarbon poolfire. T2 - CISAP 11 CY - Neapel, Italy DA - 15.09.2024 KW - Liquefied hydrogen KW - LNG KW - Fire KW - Insulation KW - MLI PY - 2024 AN - OPUS4-61389 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -