TY - CONF A1 - Neugum, Tim T1 - Application of the substructure method to assess the fire resistance of thermally restrained columns N2 - Usually, the fire resistance of load-bearing structural elements is determined by single members testing. A mechanical load is applied to the member in a force-controlled manner and is maintained constant throughout the fire test. After applying the mechanical load, the thermal exposure starts according to the ISO 834 fire curve. In this conventional test method, no interaction between the tested member and the entire building structure is considered. In buildings, the surrounding structure can restrain the thermal expansion of a member in case of fire. This may have both positive and negative effects on the fire resistance of this structural element. Several years ago, the Institute for Sustainability and Innovation in Structural Engineering (ISISE) at the University of Coimbra in Portugal and the Bundesanstalt für Materialforschung und prüfung (BAM) in Germany carried out fire tests on circular and square steel-reinforced concrete columns with restrained thermal expansion. BAM´s column test furnace allows the specimen to be subjected to thermal exposure and mechanical loading simultaneously. In addition, this device has a substructure test module, which can also provide restrained test conditions. In an ongoing research project at BAM and Technische Universität Braunschweig, the effect of restrained test conditions on the behaviour of steel-reinforced columns under fire exposure is further investigated. T2 - 8th International RILEM Workshop on Concrete Behaviour due to Fire Exposure CY - Krakow, Poland DA - 18.09.2025 KW - Substructure method KW - Surrounding structure KW - Fire resistance KW - Column KW - Concrete PY - 2025 AN - OPUS4-64584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neugum, Tim A1 - Stelzner, Ludwig A1 - Häßler, Dustin A1 - Zehfuß, Jochen A1 - Hothan, Sascha T1 - Application of the substructure method to assess the fire resistance of thermally restrained columns N2 - Usually, the fire resistance of load-bearing structural elements is determined by single members testing. A mechanical load is applied to the member in a force-controlled manner and is maintained constant throughout the fire test. After applying the mechanical load, the thermal exposure starts according to the ISO 834 fire curve. In this conventional test method, no interaction between the tested member and the entire building structure is considered. In buildings, the surrounding structure can restrain the thermal expansion of a member in case of fire. This may have both positive and negative effects on the fire resistance of this structural element. Several years ago, the Institute for Sustainability and Innovation in Structural Engineering (ISISE) at the University of Coimbra in Portugal and the Bundesanstalt für Materialforschung und prüfung (BAM) in Germany carried out fire tests on circular and square steel-reinforced concrete columns with restrained thermal expansion. BAM´s column test furnace allows the specimen to be subjected to thermal exposure and mechanical loading simultaneously. In addition, this device has a substructure test module, which can also provide restrained test conditions. In an ongoing research project at BAM and Technische Universität Braunschweig, the effect of restrained test conditions on the behaviour of steel-reinforced columns under fire exposure is further investigated. T2 - 8th International RILEM Workshop on Concrete Behaviour due to Fire Exposure CY - Krakow, Poland DA - 18.09.2025 KW - Substructure method KW - Surrounding structure KW - Fire resistance KW - Restrained columns KW - Concrete PY - 2025 SP - 1 EP - 2 AN - OPUS4-64582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tabaka, Weronika A1 - Meinel, Dietmar A1 - Schartel, Bernhard T1 - Sacrifice Few to Save Many: Fire Protective Interlayers in Carbon- Fiber-Reinforced Laminates N2 - The fire protection of carbon-fiber-reinforced polymer (CFRP) laminates often relies on flame-retardant coatings, but in some applications, their efficacy may diminish upon direct fire exposure due to rapid pyrolysis. This study introduces an innovative approach by integrating protective interlayers within the laminate structure to enhance the fire resistance. Various materials, including ceramic composite WHIPOX, titanium foil, poly(etherimide) (PEI) foil, basalt fibers, rubber mat, and hemp fibers, were selected as protective interlayers. These interlayers were strategically placed within the laminate layout to form a sacrificial barrier, safeguarding the integrity of the composite. Bench-scale fire resistance tests were conducted, where fire (180 kW/m2) was applied directly to the one side of the specimen by a burner while a compressive load was applied at the same time. Results indicate significant prolongation of time to failure for CFRP laminates with protective interlayers, which is up to 10 times longer. This innovative approach represents a potential advance in fire protection strategies for CFRP laminates, offering improved resilience against fire-induced structural failure. KW - Composites in fire KW - Fire resistance KW - Fire retardant interlayers KW - Laminate design KW - Carbon fibre reinforced PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-601943 DO - https://doi.org/10.1021/acsomega.4c01408 SN - 2470-1343 VL - 9 IS - 22 SP - 23703 EP - 23712 PB - ACS AN - OPUS4-60194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tabaka, Weronika T1 - Bench-scale fire stability testing - Protective layers in carbon fibre reinforced polymer laminates N2 - Fire resistance testing of components made of carbon fibre reinforced polymers (CFRP) composites usually demands intermediate-scale or full-scale testing. In this study, a bench-scale test is presented as a practicable and efficient method to assess the improvement in structural integrity of CFRP with different protective interlayers during fire. T2 - International Conference on Composite Materials (ICCM23) CY - Belfast, UK DA - 30.07.2023 KW - Fire resistance KW - Bench-scale testing KW - Carbon fibre reinforced polymer composite PY - 2023 AN - OPUS4-58099 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tabaka, Weronika T1 - Bench-scale fire stability testing of carbon fibre reinforced polymer laminates with protective layers N2 - Fire resistance testing of components made of carbon fibre reinforced polymers (CFRP) composites usually demands intermediate-scale or full-scale testing. In this study, a bench-scale test is presented as a practicable and efficient method to assess the improvement in structural integrity of CFRP with different protective interlayers during fire. Fire stability is one of the biggest issues of carbon fibre reinforced polymer (CFRP) composites, particularly when they are using in load bearing applications. As soon as the glass transition temperature of polymer matrix (100-200°C) is achieved, the composite loses its structural integrity, what leads to the distortion and failure. The principal fire stability test is based on simultaneous application of fire and mechanical load. Since the carbon fibres can transfer the tensile loads quite well, the compression load is chosen as a required mechanical load for a test. The fire tests were preceded by a static load test at room temperature to determine ultimate failure load. The specimen was loaded with a compression force until the failure load was reached, which was observed as a buckling. For the fire tests, 10% of compression failure load and direct flame of a fully developed fire (heat flux ≈ 180 kW m-2) were applied simultaneously to the specimen, while the time to failure was measured. The possibilities of bench-scale fire stability testing were presented by investigating new types of laminate structures, which exhibit promising flame retardancy and fireproof properties. The new approach of CFRP laminate differs with a protective concept. Every system consists of two different interlayers (titanium foil, thermoplastic foil PEI, ceramic layer WHIPOX, rubber tape Pyrostat, basalt fibres and kenaf fibres), where the one layer constitutes the fireproof protection, that delays the rise of temperature in the rest of laminate, and the second layer provides very good structural connection with carbon fibre layers, thus improves the mechanical integrity of CFRP composite in fire. The time to failure of CFRP composite was 17s. Protective systems significantly enhance the fire stability and increased time to failure by 3 to 10 times. Thicker specimens showed longer resistance time, however CFRP laminate with ceramic layer and titanium foil presented outstanding results and the best performance. The protection with Kenaf and basalt fibres offered a natural fibre solution with also good fire resistance performance Although bench-scale tests are limited with respect to assessing the performance of components and structures, they are valuable in the assessment of different materials concepts. Furthermore, the reduced effort of conducting bench-scale test (lower costs, time, personnel resources) makes it more practical and effective. T2 - 19th European meeting on Fire Retardant Polymeric Materials (FRPM23) CY - Dübendorf, Switzerland DA - 26.06.2023 KW - Fire resistance KW - Carbon fibre reinforced polymer KW - Bench-scale testing PY - 2023 AN - OPUS4-57880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -