TY - GEN A1 - Wiesner, Anja A1 - Neumann, Patrick P. A1 - Krentel, Daniel A1 - Patzelt, Anne-Katrin T1 - Übersicht IFAFRI Capability Gaps N2 - Die zehn Capability Gaps der IFAFRI (International Forum to Advance First Responder Innovation) werden zusammengefasst und übersichtlich dargestellt. KW - BOS KW - KMU KW - IFAFRI KW - Security KW - Safety PY - 2021 SP - 1 EP - 10 CY - Berlin AN - OPUS4-53624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Cozzolino, Chiara A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Safety Assessment of MLI Super-Insulation Systems for Cryogenic Liquid-Hydrogen Tanks in Fire Scenarios N2 - In the context of green energy transition, cryogenic tanks insulated by MLI and vacuum are emerging as a leading solution to store hydrogen in heavy-duty vehicles. However, the integrity of such tanks can be jeopardized by fire. In such a scenario, MLI materials degradation can occur, leaving the tank unprotected from the fire heat flux, with consequent rapid pressurization and a high risk of failure. This study presents a safety assessment of non-combustible MLI under fire exposure based on the estimation of the time to mechanical failure of the equipment. This is calculated through an innovative model that simulates the thermomechanical response of the tank, including the MLI thermal degradation and the pressure-relief valve (PRV) operation. The application to several case studies that consider a typical LH2 tank featuring a wide range of MLI configurations demonstrated the likelihood of failure in case of exposure to a hydrocarbon pool fire, providing also comprehensive insights into the impact of the insulation characteristics and operating conditions on the time to failure. T2 - Loss Prevention 2025 CY - Bologna, Italien DA - 09.06.2025 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety KW - Tank PY - 2025 DO - https://doi.org/10.3303/CET25116036 SN - 2283-9216 IS - 116 SP - 211 EP - 216 PB - AIDIC AN - OPUS4-63739 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Storages For Cryogenic Gases And Their Safety Part 2 N2 - To accelerate the hydrogen uptake in Europe the project KICstartH2 funded by the European Union arranged the Joint European Summer School (JESS) that deals with several topics around hydrogen. A topic in this framework is the transport and storage of energy by hydrogen. Here cryogenic energy carriers are seen as having great potential. This is because they allow significantly higher volumetric energy densities to be achieved than when these energy carriers are stored at typical temperatures on Earth. This is important for numerous energy-intensive applications, such as those found in all transport sectors. Important cryogenic energy carriers include liquefied hydrogen (LH2) and liquefied natural gas (LNG). This presentation deals with the consequences of an accidental release of a cryogenic liquid and the consequences of a fire affecting a tank. T2 - Joint European Summer School (JESS) CY - Athens, Greece DA - 15.09.2024 KW - Liquefied hydrogen KW - Liquefied natural gas KW - Cryogenic storage tank KW - Fire KW - Safety KW - Consequences PY - 2024 AN - OPUS4-61084 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, D. A1 - Scarponi, G. E. A1 - Cozzani, V. A1 - Otremba, Frank T1 - Insulation Materials Used in Tanks for the Storage of Cryogenic Fluids in Fire Scenarios N2 - The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure. What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank. The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires. The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures. T2 - ASME 2023 Pressure Vessels & Piping Conference (PVP2023) CY - Atlanta, Georgia, USA DA - 16.07.2023 KW - LH2 KW - LNG KW - Fire KW - MLI KW - Safety PY - 2023 AN - OPUS4-57974 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Heßmann, Jennifer A1 - Werner, Jan A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Investigation of realistic fire scenarios involving cryogenic storage tanks N2 - The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences. T2 - 18th EFCE International Symposium on Loss Prevention and Safety Promotion in the Process Industries CY - Bologna, Italy DA - 08.06.2025 KW - LH2 KW - Insulation KW - Fire KW - Liquefied Natural Gas KW - Safety PY - 2025 AN - OPUS4-63425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hofmann-Böllinghaus, Anja A1 - Brandt, J. ED - Troitzsch, J. ED - Antonatus, E. T1 - Motor Vehicles N2 - The amount of plastic and synthetic materials is still growing in all sectors of everyday life. In the automotive industry, plastic materials are now widely used in vehicles because of their excellent mechanical properties and their light weight combined with low production costs. However, plastic materials are flammable and can generate toxic smoke gases which can endanger passengers’ lives in the event of fire. KW - Transport KW - Bus fire KW - Safety PY - 2021 SN - 978-1-56990-762-7 VL - 2021 SP - 537 PB - Hanser CY - München ET - 4 AN - OPUS4-53094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Systems With Cryogenic Liquefied Gases In Fire-Incidents N2 - The volumetric energy density of a gas can be increased by liquefaction, which occurs when the gas is cooled below the saturation point. Liquefied gases of great importance to the energy transition are Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG), which can be liquefied at temperatures below 160°C. Systems for storing these gases typically must be overpressure resistant and require thermal super insulations (TSI) to hold cryogenic conditions and minimize boil-off losses from evaporation. TSI with vacuum and MLI or perlites are suitable for many applications involving LNG and LH2. Such systems are typically double-walled structures where the inner wall is in contact with the cryogenic liquefied gas. MLI or perlites are located in the gap between the inner and the outer wall, that is kept under vacuum conditions. This combination of insulations strongly reduces the heat transfer between the environment and the cryogenic liquefied gas. From an economic point of view the systems are well sophisticated. However, knowledge of the behavior of this kind of systems in a typical event such as a fire is limited, but necessary to evaluate the safety of the increasing number of applications. The objective of the research is to determine how TSI behaves at different fire temperatures during fire exposure and afterwards. Special attention is paid to changes in the heat flux, the material properties and vacuum state over time. For this purpose, thermogravimetric analysis (TGA) studies have been carried out. In addition, a test rig was developed that allows testing of TSI at temperatures up to 1000°C under realistic integration conditions and subsequent analysis of the TSI samples. In the test rig the double-wall with vacuum and MLI or perlites inside is simulated. The fire conditions are simulated on one side of the double-wall by adjustable electrical heating elements. This process allows the implementation of repeatable heat flows of up to 100 kW/m². On the other side of the double-wall, cold or cryogenic conditions are simulated with a heat exchanger through which water or the vapor of liquid nitrogen (approx. -196°C) flows. The heat exchanger is also used to determine the heat flux through the double-wall. Thus, the test rig allows thermal loading and performance analysis of TSI samples at the same time. Compared to tests with real cryogenic systems, tests with this experimental setup have the advantage that, first, the instrumentation is easier to realize, and a higher repeatability is ensured. Second, the local heat flow can be determined over time, and the sample of a TSI can be taken non-destructively and thus analyzed. Third, the tests are less risky as well as time+ and material intensive, so that more tests and variants can be investigated with the same budget. Preliminary results obtained considering several types of MLI under vacuum show that all observed typs of MLI can be damaged under strong thermal loading. The damages observed were outgassing, melting, shrinkage, cracking, lump formation, and concomitant local loss of the MLI's function as a radiation shield. However, the study also shows that a damage does not always have an extreme effect on the insulating performance. T2 - IMECE2022 CY - Columbus, Ohio, USA DA - 30.10.2022 KW - LH2 KW - LNG KW - Safety KW - Insulation KW - Tank PY - 2022 AN - OPUS4-56445 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR ED - Hofmann-Böllinghaus, Anja ED - Anderson, J. T1 - Special issue: Facade fire safety N2 - Façade fires are of growing concern worldwide. Severe facade fires in different parts of the world as well as activities in many countries regarding the testing of facades show the urgency of the fire safety challenges in façade fires. The need for knowledge and a wide Archive of work in this area has become evident after recent incidents which involved extensive facade fires. These include the tragic fires in Dubai and Grenfell Tower in 2017 in the United Kingdom. In many cases, the widespread live news coverage of the events and size of These fires has emphasized the need for progress in the understanding of the processes involved in these fires and put pressure upon the fire safety engineering community to find effective solutions. KW - Testing KW - Safety PY - 2021 UR - https://onlinelibrary.wiley.com/toc/10991018/2021/45/5 SN - 0308–0501 SN - 1099-1018 VL - 45 IS - 5 SP - 583 EP - 696 PB - Wiley CY - Oxford AN - OPUS4-53102 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Scarponi, Giordano T1 - Performance of MLI systems for LH2 Tanks in fire scenarios N2 - In the course of decarbonizing the energy industry, cryogenic energy carriers are seen as having great potential. This is because they allow significantly higher volumetric energy densities to be achieved than when these energy carriers are stored at typical temperatures on Earth. This is important for numerous energy-intensive applications, such as those found in all transport sectors. Important cryogenic energy carriers include liquefied hydrogen (LH2) and liquefied natural gas (LNG). The challenge is to keep the energy carrier cold for a long time. This is achieved by the implementation of thermal super-insulations (TSI) systems based on multilayer insulations (MLI), microspheres, perlites, and vacuum for instance, and which have proven to be effective in several cryogenic applications. However, due to the short period of use, the low number of documented incidents, and the still few investigations carried out in the field, the exploitation of such systems in the transport sector still suffers from insufficient knowledge about the course and consequences of incidents. Accidents involving collisions, fires, and their combination are quite common in the transportation sector and may generate extraordinary loads on the tank and its insulation system, eventually leading to tank failure. The presentation summarizes the findings from the cooperation of the University of Bologna and BAM regarding the experiments on diverse types of super-insulations with the High Temperature Thermal Vacuum Chamber, as well as the model approaches that were developed to calculate the heat transfer and degradation of MLI’s during high thermal exposure. As an outlook the application of the models, the Cryogenic High Temperature Thermal Vacuum Chamber, and the fire test on HGV-components are presented. T2 - ELVHyS - International Stakeholder's Seminars CY - Bologna, Italy DA - 30.09.2024 KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Fire KW - Safety PY - 2024 AN - OPUS4-61205 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Chianese, Carmela A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios N2 - Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes. KW - Multilayer Insulation KW - Cryogenic Vessels KW - Liquefied Hydrogen KW - Liquefied Natural Gas KW - Safety KW - Fire PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-599418 DO - https://doi.org/10.1016/j.psep.2024.04.061 SN - 0957-5820 VL - 186 SP - 1169 EP - 1182 PB - Elsevier B.V. AN - OPUS4-59941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Lh2 Tanks In Fire Incidents - The Cryogenic High Temperature Thermal Vacuum Chamber Enables In-Depth Insights N2 - Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Their storage requires tanks with thermal super-insulations to keep them at cryogenic conditions for a long time. These insulation systems have proven itself in various applications over a long time. However, these insulations are still new in land transportation, where accidents involving collisions, fires, and their combination are to be expected. This study summarizes the results of the ongoing research program in which insulations commonly used in industry were analysed through experimental and numerical studies under fire-like conditions. It was found that there are strong differences among the various insulation systems. Several safety concerns and research gaps exists for layered insulations, which are typically used in land transport. To further analyse these insulation systems, a new test concept called Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC) was developed and manufactured. This concept enables the testing of large insulation samples under industrial conditions and the consideration of cryogenic conditions relevant for the investigation of various phenomena. The results are important for the evaluation of accident scenarios, the improvement of thermal super-insulations, and the development of emergency measures. T2 - IMECE 2024 CY - Oregon, Portland, USA DA - 17.11.2024 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety PY - 2024 SN - 978-0-7918-8869-8 SP - 1 EP - 7 PB - ASME AN - OPUS4-61751 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - LH2 Tanks In Fire Incidents - The Cryogenic High Temperature Thermal Vacuum Chamber Enables In-Depth Insights N2 - Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Their storage requires tanks with thermal super-insulations to keep them at cryogenic conditions for a long time. These insulation systems have proven itself in various applications over a long time. However, these insulations are still new in land transportation, where accidents involving collisions, fires, and their combination are to be expected. This study summarizes the results of the ongoing research program in which insulations commonly used in industry were analysed through experimental and numerical studies under fire-like conditions. It was found that there are strong differences among the various insulation systems. Several safety concerns and research gaps exists for layered insulations, which are typically used in land transport. To further analyse these insulation systems, a new test concept called Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC) was developed and manufactured. This concept enables the testing of large insulation samples under industrial conditions and the consideration of cryogenic conditions relevant for the investigation of various phenomena. The results are important for the evaluation of accident scenarios, the improvement of thermal super-insulations, and the development of emergency measures. T2 - IMECE 2024 CY - Portland, OR, USA DA - 17.11.2024 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety PY - 2024 AN - OPUS4-61752 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Otremba, Frank A1 - Camplese, Davide A1 - Scarponi, Giordano E. A1 - Cozzani, Valerio A1 - Seidlitz, Holger T1 - Repeatable testing of a cryogenic storage tank with variable insulation material in fire like conditions N2 - For decarbonizing the energy industry and transport, cryogenic energy carriers have great potential. The storage takes place in tanks with thermal super-insulations, which are in application for decades, but there is only limited knowledge about its behaviour in a fire scenario. This represents a major incident that may generate extraordinary loads on the tank and its insulation system, and that eventually lead to a sudden tank failure. This paper presents a test rig called the Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC), which can be used to test typical thermal superinsulation’s under cryogenic and fire-like conditions in parallel. The test method makes it possible to measure the heat flow through the thermal superinsulation over time and to investigate the degradation behaviour of the insulation within a test. In the paper results from the first tests are presented. T2 - 18th Cryogenics 2025, IIR Conference CY - Prague, Czech Republic DA - 07.04.2025 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety PY - 2025 DO - https://doi.org/10.18462/iir.cryo.2025.0007 SP - 205 EP - 210 CY - Prag AN - OPUS4-63740 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - New concepts in liquid hydrogen storage N2 - On the way to the energy transition, cryogenic fluids such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) are very important. They enable the large-scale economic transport and storage of energy as well as they represent alternative fuels for energy-intensive mobile applications such as aircrafts, ships and HGVs. For the last one, the number of vehicles and fuel stations has increased rapidly in the last 10 years all over Europe. Does this also entail new risks, for instance from a BLEVE in case of fires? To answer this question, BAM has conducted several research projects over the last decades and intensified the research recently with several experimental, numerical, and empirical outcomes on how a tank with insulation behaves in a fire. The presentation shows an overview of this research. The findings are relevant for global standardization procedures and to improve the overall safety in chemistry and technics. T2 - Hydrogen Refueling Station Opening CY - Baruth/Mark, Germany DA - 03.07.2025 KW - LH2 KW - Insulation KW - Fire KW - LNG KW - Safety PY - 2025 AN - OPUS4-63628 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eberwein, Robert A1 - Heßmann, Jennifer A1 - Werner, Jan A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Investigation of Realistic Fire Scenarios Involving Cryogenic Storage Tanks N2 - The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences. T2 - Loss Prevention 2025 CY - Bologna, Italien DA - 09.06.2025 KW - LH2 KW - LNG KW - Fire KW - Tank KW - Safety PY - 2025 DO - https://doi.org/10.3303/CET25116031 SN - 2283-9216 IS - 116 SP - 181 EP - 186 PB - AIDIC AN - OPUS4-63738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -