TY - JOUR A1 - Fürst, Richard A1 - Hejtmanek, P. A1 - Vlach, T. A1 - Repka, J. A1 - Mozer, V. A1 - Hajek, P. T1 - Experimental Evaluation of Carbon Reinforced TRC with Cement Suspension Matrix at Elevated Temperature N2 - Textile-reinforced concrete (TRC) is a new composite material comprising high-performance concrete and textile reinforcement from textile yarns with a matrix, usually consisting of epoxy resins (ER). The most significant advantage of ER is the homogenization of all filaments in the yarn and full utilization of its tensile potential. Nevertheless, ER matrix is a critical part of TRC design from the perspective of the fire resistance due to its relatively low resistance at temperatures of approximately 120 C. This work expands the previously performed mechanical tests at normal temperatures with cement suspension (CS) as a non-combustible material for the yarn matrix. Here, the mechanical properties of CS matrix at elevated temperatures were verified. It was found that the addition of polypropylene fibers into HPC negatively affected the mechanical results of CS matrix specimens. Simultaneously, thermal insulation effect of the covering layers with different thicknesses did not significantly influence the residual bending strength of specimens with CS matrix and achieved similar results as reference specimens. Furthermore, all specimens with ER matrix progressively collapsed. Finally, CS as a textile reinforcement of yarn matrix appears to be a suitable solution for increasing the temperature resistance of TRC structures and for substituting synthetic resins. KW - Cement matrix KW - Cement suspension KW - Carbon fibers KW - Textile reinforced concrete KW - High-performance concrete KW - Elevated temperature KW - Fire safety KW - Fire resistance PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-550766 DO - https://doi.org/10.3390/polym14112174 SN - 2073-4360 VL - 14 IS - 11 SP - 1 EP - 16 PB - MDPI CY - Basel, Switzerland AN - OPUS4-55076 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Thoralf A1 - Ebell, Gino T1 - Grundlagen der Korrosion N2 - Darstellung der Grundlagen der elektrochemischen Korrosion von metallenen Werkstoffen im Bauwesen. Dabei liegt das Hauptaugenmerk auf dem Zusammenhang zwischen Energieaufwand für den Herstellungsprozess und daraus resultierendem thermodynamisch instabilen Zustand und Korrosionsneigung. Der Einfluss der Deckschicht- Oxidschichtbildung wird ebenfalls behandelt. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 CY - Baruth/Mark, Germany DA - 16.05.2022 KW - Korrosion KW - Potentialfeldmessung PY - 2022 AN - OPUS4-54868 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Elektrochemische Messungen N2 - Elektrochemische Messungen könne, richtig angewandt, dazu dienen ein Korrosionssystem ausreichend gut zu beschreiben. Im Bauwesen, speziell bei Stahl in Beton, ist es jedoch ohne Kenntnis der korrodierenden Flächen oft nur möglich zwischen aktiv korrodierenden Bereichen und passiven, als Kathode wirksamen, Bereichen zu differenzieren. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 CY - Baruth/Mark, Germany DA - 16.05.2022 KW - Potentialfeldmessung KW - Korrosion PY - 2022 AN - OPUS4-54869 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Merkblatt B 03 der DGZfP - Ausgabe April 2014 N2 - Durch das alkalische Porenwassermilieu ist Stahl im Beton vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Karbonatisierung, Chlorideintrag) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Im weiteren Verlauf können sich korrosionsbedingte Folgeschäden, wie Risse und Abplatzungen am Bauwerk ergeben. Um notwendige Sanierungsmaßnahmen sind frühzeitige und weitgehend zerstörungsfrei ermittelte Informationen über das aktuelle Korrosionsverhalten der Stahlbewehrung von großer Bedeutung. Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 CY - Baruth/Mark, Germany DA - 16.05.2022 KW - Korrosion KW - Potentialfeldmessung PY - 2022 AN - OPUS4-54870 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Spitzer, Stefan A1 - Jankuj, V. A1 - Krietsch, Arne T1 - Comparative Study on Standardized Ignition Sources Part 2: Exploration of the Initial Igniting Volume of Standardized Ignition Sources for the Determination of Explosion Characteristics N2 - There are several standardized ignition sources in use for the determination of explosion characteristics of gases, vapors and dusts. In the standards the ignition source is stated, but they vary in stating other characteristics like burning duration, energy or burning volume. Since heat is not visible under normal circumstances a Schlieren-Technique was used to make the full heating volume and not just the flames visible. While an earlier paper of the authors focused on the ignition energy and burning duration of four standardized ignition sources, this paper focuses on the initial igniting volume, the ratio between initial igniting volume and the test-vessel size and other phenomena that were observed with the Schlieren-Technique-. T2 - Loss Prevention CY - Prag, Czechia DA - 06.06.2022 KW - Ignition source KW - Hybrid Mixtures KW - 20L-sphere PY - 2022 DO - https://doi.org/10.3303/CET2290087 SN - 2283-9216 VL - 2022 IS - 90 SP - 517 EP - 522 PB - AIDIC CY - Milano AN - OPUS4-55028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Spitzer, Stefan T1 - Comparative Study on Standardized Ignition Sources Part 2: Exploration of the Initial Igniting Volume of Standardized Ignition Sources for the Determination of Explosion Characteristics N2 - There are several standardized ignition sources in use for the determination of explosion characteristics of gases, vapors and dusts. In the standards the ignition source is stated, but they vary in stating other characteristics like burning duration, energy or burning volume. Since heat is not visible under normal circumstances a Schlieren-Technique was used to make the full heating volume and not just the flames visible. While an earlier paper of the authors focused on the ignition energy and burning duration of four standardized ignition sources, this paper focuses on the initial igniting volume, the ratio between initial igniting volume and the test-vessel size and other phenomena that were observed with the Schlieren-Technique. T2 - Loss Prevention CY - Prague, Czech Republic DA - 06.06.2022 KW - Ignition source KW - Hybrid Mixtures KW - 20L-sphere PY - 2022 AN - OPUS4-55029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lehmann, Jens A1 - Ebell, Gino T1 - Erörterung des Messprotoklls N2 - Das für die Potentialfeldmessung in der neusten Ausgabe des Merkblattes B03 der DGZfP erarbeitete Messprotokoll berücksichtigt sowohl en Einsatz, von Stab-, Einrad- oder Vierradelektroden. In diesem Vortrag wird auf alle varianten des Gegenmessen von Bezugselektroden im Einsatz eingegangen, ebenso wie auf das Erfassen der notwendigen Randparameter. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 CY - Baruth/Mark, Germany DA - 16.05.2022 KW - Korrosion KW - Potentialfeldmessung PY - 2022 AN - OPUS4-54871 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Mögliche Fehlerquellen in der Praxis N2 - Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. Bei der Durchführung dieser Messung gibt es jedoch messtechnikspezifische Fehlerquellen und äußere Einflüsse aus dem zu untersuchenden Bauwerk die eine Interpretation der Messergebnisse signifikant beeinflussen können. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 CY - Baruth/Mark, Germany DA - 16.05.2022 KW - Korrosion KW - Potentialfeldmessung PY - 2022 AN - OPUS4-54872 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF ED - Ebell, Gino T1 - Sammelmappe zum Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 N2 - Die Sammelmappe umfasst alle Lehrinhalte für den Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022, der vom 16. bis 18.05.2022 in Baruth/Mark stattgefunden hat. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen 2022 CY - Baruth/Mark, Germany DA - 16.05.2022 KW - Korrosion KW - Potentialfeldmessung PY - 2022 SP - 1 EP - 82 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-54873 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Spannbetonbauwerke - Von der Initiierung zum Schaden N2 - Wasserstoffinduzierte Spannungsrisskorrosion an hochfesten und hochempfindlichen Spannstählen führt an bestehenden Brückenbauwerken nach Jahren der Rissinitiierung zu Trag- und Standsicherheitsverlusten. Anhand des Beispiels der Brücke am Altstädter Bahnhof gibt es eine bauartbedingte Schadensinitiierung die über den gesamten Spannkanalquerschnitt zu Spannungsrisskorrosion führen kann. T2 - AK-Sitzung Korrosionsschutz im konstruktiven Ingenieurbau CY - Online meeting DA - 12.05.2022 KW - Spannungsrisskorrosion KW - Korrosion PY - 2022 AN - OPUS4-54874 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Winkler, Nicolas P. A1 - Schugardt, Jan ED - Rudnitskaya, A. T1 - Remote Drone-to-Drone Gas Sensing: A Feasibility Study N2 - Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or poorly accessible areas. A challenging task however, is the generation of three-dimensional distribution maps from these spatially sparse gas measurements. To obtain high-quality reconstructions, the choice of optimal measuring poses is of great importance. Remote gas sensors, that are commonly used in Robot Assisted Gas Tomography (RAGT), require reflecting surfaces within the sensor’s range, limiting the possible sensing geometries, regardless of whether the robots are ground-based or airborne. By combining ground and aerial robots into a heterogeneous swarm whose agents are equipped with reflectors and remote gas sensors, remote inter-robot gas measurements become available, taking RAGT to the next dimension – releasing those constraints. In this paper, we demonstrate the feasibility of drone-to-drone measurements under realistic conditions and highlight the resulting opportunities. T2 - 19th International Symposium on Olfaction and Electronic Nose CY - Aveiro, Portugal DA - 29.05.2022 KW - Aerial robot KW - TDLAS KW - Inter-robot measurements KW - Gas tomography KW - Plume PY - 2022 SN - 978-1-6654-5860-3 DO - https://doi.org/10.1109/isoen54820.2022.9789627 SP - 1 EP - 3 PB - IEEE CY - USA AN - OPUS4-54926 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Winkler, Nicolas P. A1 - Schugardt, Jan T1 - Remote Drone-to-Drone Gas Sensing: A Feasibility Study N2 - Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or poorly accessible areas. A challenging task however, is the generation of three-dimensional distribution maps from these spatially sparse gas measurements. To obtain high-quality reconstructions, the choice of optimal measuring poses is of great importance. Remote gas sensors, that are commonly used in Robot Assisted Gas Tomography (RAGT), require reflecting surfaces within the sensor’s range, limiting the possible sensing geometries, regardless of whether the robots are ground-based or airborne. By combining ground and aerial robots into a heterogeneous swarm whose agents are equipped with reflectors and remote gas sensors, remote inter-robot gas measurements become available, taking RAGT to the next dimension – releasing those constraints. In this paper, we demonstrate the feasibility of drone-to-drone measurements under realistic conditions and highlight the resulting opportunities. T2 - 19th International Symposium on Olfaction and Electronic Nose CY - Aveiro, Portugal DA - 29.05.2022 KW - Aerial robot KW - TDLAS KW - Inter-robot measurements KW - Gas tomography KW - Plume PY - 2022 AN - OPUS4-54927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Gödde, M. A1 - Salg, S. A1 - Erdt, René T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prag, Czechia DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 SN - 978-88-95608-88-4 DO - https://doi.org/10.3303/CET2290049 SN - 2283-9216 VL - 90 SP - 289 EP - 294 PB - AIDIC AN - OPUS4-55079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Erdt, René A1 - Gödde, M. A1 - Salg, S. T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prague, Czech Republic DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 AN - OPUS4-55080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Häßler, Dustin A1 - Hothan, Sascha T1 - Performance of intumescent fire protection coatings applied to structural steel tension members with circular solid and hollow sections N2 - Intumescent fire protection coatings are used to improve the fire resistance of steel members. Due to slender cross-sections typically used for tension members, high demands are placed on the effectiveness and reliability of the intumescent coatings. This paper describes real-scale fire tests of intumescent coatings applied to steel tension members with circular solid and hollow sections. First, the current regulations for the application of intumescent coatings on steel tension members are discussed. After that, a comparison between the foaming behaviour and failure mechanisms of intumescent coatings applied to steel tension members with different cross-sections and loading conditions is given. Next, the experimental setup and procedure of the performed fire tests are presented. In addition, the influences of various parameters on the performance of the intumescent coating are analysed, including the geometry of the steel profile, dry film thickness of the intumescent coating, load utilisation level as well as the orientation of the member. Based on the theoretical considerations and results of the fire tests, it is evidenced that mechanically loaded fire tests are essential to assess accurately the contribution of intumescent fire protection coatings to the fire resistance of steel tension members with circular solid sections. KW - Fire tests KW - Intumescent coating KW - Reactive fire protection system KW - Steel KW - Tension members PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-548981 DO - https://doi.org/10.1016/j.firesaf.2022.103605 SN - 0379-7112 VL - 131 SP - 1 EP - 12 PB - Elsevier Ltd. AN - OPUS4-54898 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Hothan, Sascha T1 - Influence of the profile type and bar orientation on the performance of intumescent coatings applied to steel tension bars N2 - Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Especially in the case of tension bars, where mostly circular or rectangular solid sections are used, intumescent coatings offer an efficient measure to improve the fire resistance taking advantage of profile-following application and low coating thickness requirements. Thus, the architectural appearance of slender profiles can be preserved. The paper describes real-scale mechanically loaded and unloaded fire tests of circular and rectangular solid steel tension bars with intumescent coating. The aim of these tests is to investigate the influence of the different profile types as well as different bar orientations on the performance of intumescent coatings. The results are used to specify a normative test and assessment procedure to be implemented in a new European standard for determining the contribution of intumescent coatings to the fire resistance of circular or rectangular bars used as tension members. KW - Fire test KW - Intumescent coating KW - Steel tension member KW - Fire resistance PY - 2022 DO - https://doi.org/10.1016/j.firesaf.2022.103678 SN - 0379-7112 VL - 134 SP - 1 EP - 14 PB - Elsevier CY - Amsterdam AN - OPUS4-56172 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Wasserstoff - Kryogene Anwendungen N2 - Wasserstoff wird als ein potenzieller alternativer Energieträger gesehen, mit dem die für 2050 gesetzten Klimaziele erreicht werden könnten. Der Transport von Wasserstoff ist mittels verschiedener Speichertechniken möglich, von denen der kryogene Transport mit den größten volumetrischen Energiedichten einhergeht. Hierdurch eignen sich diese Speicher besonders für die energieintensiven Verkehrsmittel im Land-, See- und Flugverkehr. Im Vortrag werden Speichertechniken, Gefahren im Umgang mit kryogenen Gasen sowie bisherige Störfälle dargestellt. Darauf aufbauend wird ein Teil der aktuellen Forschungsarbeit an der BAM vorgestellt, die die Sicherheit dieser Speicher unter außergewöhnlichen Belastungen adressiert. T2 - 26. Gefahrgutkongress Mecklenburg-Vorpommern CY - Rostock, Germany DA - 03.11.2022 KW - Wasserstoff KW - H2 KW - LNG KW - LH2 KW - Tank PY - 2022 AN - OPUS4-56181 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lu, Xin A1 - Schukar, Marcus A1 - Krebber, Katerina T1 - Characterizing vibration response of fiber cables for distributed acoustic sensing N2 - The vibration responses of two fiber cables are characterized up to 16 kHz and compared with a standard tight-buffered 900 um fiber. The response of the cables is suppressed due to the cable protection T2 - 27th International Conference on Optical Fiber Sensors (OFS-27) CY - Alexandria, VA, USA DA - 29.08.2022 KW - Response characterization KW - Distributed fiber sensing KW - Acoustic sensing PY - 2022 SP - 1 EP - 4 PB - Optica CY - Washington D.C., USA AN - OPUS4-56096 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lu, Xin A1 - Schukar, Marcus A1 - Weege, S. A1 - Roske, T. A1 - Krebber, Katerina T1 - Leakage detection at a borehole simulator using distributed acoustic sensing N2 - A distributed acoustic sensing system is used to detect the leakage in a borehole simulator by measuring the leakage induced vibration. The leakage location can be clearly determined by frequency spectrum analysis. T2 - 27th International Conference on Optical Fiber Sensors (OFS-27) CY - Alexandria, VA, USA DA - 29.08.2022 KW - Leakage detection KW - Structural health monitoring KW - Distributed fiber sensing KW - Distributed acoustic sensing PY - 2022 SP - 1 EP - 4 PB - Optica CY - Washington D.C., USA AN - OPUS4-56097 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lu, Xin A1 - Schukar, Marcus A1 - Weege, S. A1 - Roske, T. A1 - Krebber, Katerina T1 - Leakage detection at a borehole simulator using distributed acoustic sensing N2 - A distributed acoustic sensing system is used to detect the leakage in a borehole simulator by measuring the leakage induced vibration. The leakage location can be clearly determined by frequency spectrum analysis. T2 - 27th International Conference on Optical Fiber Sensors (OFS-27) CY - Alexandria, VA, USA DA - 29.08.2022 KW - Structural health monitoring KW - Distributed fiber sensing KW - Distributed acoustic sensing KW - Leakage detection PY - 2022 AN - OPUS4-56098 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -