TY - JOUR A1 - Palkowski, Carsten A1 - Zottl, A. A1 - Malenkovic, I. A1 - Simo, Anne T1 - Fixing efficiency values by unfixing compressor speed: Dynamic test method for heat pumps JF - Energies N2 - The growing market penetration of heat pumps indicates the need for a performance test method that better reflects the dynamic behavior of heat pumps. In this contribution, we developed and implemented a dynamic test method for the evaluation of the seasonal performance of heat pumps by means of laboratory testing. Current standards force the heat pump control inactive by fixing the compressor speed. In contrast, during dynamic testing, the compressor runs unfixed while the heat pump is subjected to a temperature profile. The profile consists of the different outdoor temperatures of a typical heating season based on the average European climate and also includes temperature changes to reflect the dynamic behavior of the heat pump. The seasonal performance can be directly obtained from the measured heating energy and electricity consumption making subsequent data interpolation and recalculation with correction factors obsolete. The method delivers results with high precision and high reproducibility and could be an appropriate method for a fair rating of heat pumps. KW - Heat pump KW - Dynamic test method KW - Seasonal performance factor KW - Variable frequency drive KW - Energy label PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-476944 DO - https://doi.org/10.3390/en12061045 SN - 1996-1073 VL - 12 IS - 6 SP - 1045, 1 EP - 16 PB - MDPI CY - Basel, Switzerland AN - OPUS4-47694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten A1 - Simo, Anne T1 - Quick Seasonal Performance Testing for Heat Pumps T2 - ECEEE Summer Study 2019 Proceedings N2 - To determine the seasonal performance of heat pumps for energy labelling this study proposes a two-point-method that could conceivably be an alternative to the European standard EN 14825 and similar test standards such as ISO 13256. Heat pumps were tested in line with the EN 14825. The reduction of measurement points, from between five to seven (EN 14825) to only two (two-point-method), leads to 60 % savings in cost and time. It is shown that the shortened method can be used to determine the seasonal energy efficiency of heat pumps with the same degree of precision compared to EN 14825. T2 - ECEEE Summer Study 2019 CY - Hyerès, France DA - 03.06.2019 KW - Heat pump KW - Energy label KW - Testing KW - Coefficient of performance KW - Screening PY - 2019 SP - 1547 EP - 1552 AN - OPUS4-48275 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Palkowski, Carsten A1 - Schwarzenberg, S. A1 - Simo, Anne T1 - Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels JF - International Journal of Refrigeration N2 - Minimum energy performance standards and labels are commonly used tools to reduce the household energy use thus mitigating greenhouse gas emissions. However, the technical foundation for minimum energy performance standards and labels are test procedures for rating and testing of appliances. To de- termine the seasonal cooling performance of air conditioners, the current test standards require fixing of the compressor speed of the units to achieve steady-state conditions; this way of operation, how- ever, differs from real-life use. To make the seasonal cooling performance testing better reflect the real use conditions, this study proposes a compensation method which can be conducted independently from manufacturer data and still allows modulation of the tested units. Our results show that the tested units behave differently under part-load conditions, which results in a lower energy efficiency rating for some of the tested devices. KW - Air conditioner KW - Independent test method KW - Real use behavior KW - Seasonal energy efficiency ratio KW - Minimum energy performance standards KW - Energy label PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-485813 DO - https://doi.org/10.1016/j.ijrefrig.2019.05.021 SN - 0140-7007 VL - 104 SP - 417 EP - 425 PB - Elsevier AN - OPUS4-48581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten A1 - Simo, Anne T1 - Quick Seasonal Performance Testing for Heat Pumps N2 - To determine the seasonal performance of heat pumps for energy labelling this study proposes a two-point-method that could conceivably be an alternative to the European standard EN 14825 and similar test standards such as ISO 13256. Heat pumps were tested in line with the EN 14825. The reduction of measurement points, from between five to seven (EN 14825) to only two (two-point-method), leads to 60 % savings in cost and time. It is shown that the shortened method can be used to determine the seasonal energy efficiency of heat pumps with the same degree of precision compared to EN 14825. T2 - ECEEE Summer Study 2019 CY - Hyerès, France DA - 03.06.2019 KW - Heat pump KW - Energy label KW - Testing KW - Coefficient of performance KW - Screening PY - 2019 AN - OPUS4-48274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Dynamic Test Method for Heat Pumps and Air Conditioners N2 - Die bisher üblichen Verfahren zur Bewertung der Effizienz einer Wärmepumpe durch Labormessungen berücksichtigen kaum transiente Zustände. Können dynamische Bewertungsverfahren im Labor ein realistischeres Verhalten im Feld wiederspiegeln und damit zu sinnvolleren Entscheidungen führen? N2 - The commonly used methods for evaluating the seasonal performance of heat pumps in the laboratory do not consider transient conditions. Will dynamic test methods be able to better reflect real-life behavior in the field and thus lead to more appropriate decision-making? T2 - EHPA MCO CY - Brussels, Belgium DA - 10.10.2019 KW - Heat pump KW - Inverter-type air conditioner KW - Seasonal performance KW - Energy label PY - 2019 AN - OPUS4-49270 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Dynamic Test Method for Heat Pumps N2 - Vorstellung der Dynamischen Wärmepumpenprüfung beim CEN/TC 113/WG 7 N2 - Presentation of the dynamic test method for the determination of the seasonal performance of heat pumps at CEN/TC 113/WG 7. T2 - Meeting of CEN/TC 113/WG 7 CY - Stockholm, Sweden DA - 23.04.2019 KW - Heat pump KW - Energy label KW - Seasonal performance KW - Coefficient of performance PY - 2019 AN - OPUS4-48308 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knieschewski, Arno A1 - Stamminger, R. A1 - Simo, Anne T1 - Cost analysis of screening methods to find non-compliant models using the example of tumble dryers JF - Energy Efficiency N2 - The European energy label was established to reduce energy consumption in Europe. All classes and values on the energy label are stated by the supplier. The task of market surveillance is to ensure correct labels and to validate their values through compliance tests. However, this can only be done for a small fraction of all models on the market, since physical tests are expensive. Screening methods can be used to narrow down the number of critical products before compliance tests are done to decrease the costs of finding non-compliant models. This study shows a mathematical approach to analyze the cost benefits of screening methods to find non-compliant models. Furthermore, the analysis presented has been applied to 18 screening methods for tumble dryers. The performance test for tumble dryers consists of seven test runs. All screening methods evaluated are composed of a reduced number of test runs. The most efficient screening method reduces the surveillance costs by 40 %. KW - Screening method KW - Market surveillance KW - Tumble dryer KW - Energy label PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-486762 DO - https://doi.org/10.1007/s12053-019-09805-y SN - 1570-646X SN - 1570-6478 VL - 12 IS - 7 SP - 1707 EP - 1715 PB - Springer CY - Dordrecht AN - OPUS4-48676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -