TY - CONF A1 - Waske, Anja T1 - X-ray Non-destructive testing of materials and composites N2 - Functional materials for energy conversion are important technology drivers needed for the implementation of low carbon energy. Therefore, researchers commonly focus on improving the intrinsic properties of a functional material. However, for applications, the extrinsic properties are at least as important as the intrinsic ones. Consequently, it is important to investigate and understand the external and internal structure of semi-finished products and especially defect dependent properties. The extrinsic properties may change during application and the life cycle of the material as well as through processing and molding steps. Our studies show how X-ray tomographic (XCT) investigations can contribute to structure investigations in composites and massive samples using the example of magnetic materials for energy conversion. T2 - Ruhr Universität Bochum - Seminar materials science and technology CY - Online meeting DA - 12.11.2020 KW - X-ray imaging KW - Non-destructuve testing KW - Functional materials PY - 2020 AN - OPUS4-51905 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Léonard, Fabien T1 - Overview of XCT data processing workflow for ammonium nitrate prills quantitative analysis N2 - This video presents the data processing workflow that was developed to perform the quantitative structural and morphological analysis of ammonium nitrate prills by x-ray computed tomography. KW - ANFO KW - Data processing KW - Explosives KW - Porosity KW - Surface area KW - XCT PY - 2020 DO - https://doi.org/10.5281/zenodo.3611339 PB - Zenodo CY - Geneva AN - OPUS4-51897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kruschwitz, Sabine T1 - Evaluation of Advanced NDT-Methods for Measurement of Fibre Orientation in Concrete N2 - Integration of fibre reinforcement in high-performance cementitious materials has become widely applied in many fields of construction. One of the most investigated advantages of steel fibre reinforced concrete (FRC) is the deceleration of crack growth and hence it’s improved sustainability due to e.g. decrease of permeability of concrete by aggressive substances. Additional benefits are associated with the structural properties of FRC, where fibres can significantly increase the ductility and the tensile strength of concrete. In some applications, such as tunnel linings or industrial slabs, it is even possible to entirely replace the conventional reinforcement, leading to significant logistical and environmental benefits. Fibre reinforcement can, however, have critical disadvantages and even hinder the performance of concrete, since it can induce an anisotropic material behaviour of the mixture if the fibres are not appropriately oriented. For a safe use of FRC in the future, reliable non-destructive methods need to be identified to assess the fibres’ orientation in hardened concrete. In this study, ultrasonic material testing, electrical impedance testing, and X-ray computer tomography have been investigated for this purpose using specially produced samples with biased or random fibre orientations. This paper demonstrates the capabilities of each of these NDT techniques for fibre orientation measurements and draws conclusions based on these results about the most promising areas for future research and development using these techniques. T2 - fib2020 Shanghai CY - Online meeting DA - 22.11.2020 KW - Ultrasonic testing KW - Steel fibre reinforced concrete (FRC) KW - Fibre orientation KW - X-ray computed tomography (CT) KW - Electrical impedance PY - 2020 AN - OPUS4-51651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reuter, T. A1 - Plotzki, David A1 - Borges de Oliveira, F. A1 - Hausotte, T. T1 - Simulative Untersuchung des Einflusses von Bildrauschen auf dimensionelle Messungen mit industriellen Computertomografen N2 - Die industrielle Röntgen-Computertomografie (CT) etabliert sich für die Anwendung in der dimensionellen Messtechnik. Sie bietet als zerstörungsfreies Messverfahren das Potential, sowohl innen- als auch außenliegende Merkmale holistisch zu erfassen. Für die Bestimmung der Güte eines Messwerts muss die dem Messwert zugeordnete Messunsicherheit ermittelt werden. Dabei kann, nach derzeitigem Stand der Technik und Normung, die aufgabenspezifische Messunsicherheit nach VDI/VDE 2630 Blatt 2.1 nur unter hohem Aufwand mit einer Vielzahl an experimentellen Wiederholmessungen ermittelt werden. Ziel diverser Forschungs-projekte zu diesem Thema ist es daher, eine numerische Messunsicherheitsbestimmung zu erreichen. Dafür ist es notwendig, alle signifikanten Einflussgrößen zu erfassen, deren Unsicherheitsbeiträge zu bestimmen und zu bewerten. In diesem Beitrag wird der Einfluss des Bildrauschens auf verschiedene dimensionelle Messgrößen simulativ untersucht. Mithilfe eines prismatischen Prüfkörpers, der eine Vielzahl an Geometrieelementen aufweist, werden verschiedene Messgrößen unterschiedlicher Komplexität betrachtet. Ziel ist es, für diese Messgrößen zu testen, wie diese auf das Bildrauschen reagieren. Dieses wird dabei durch das Signal-Rausch-Verhältnis (SNR) der Projektionsgrauwerte beschrieben und variiert. Es werden Wiederholsimulationen durchgeführt, damit eine statistische Aussage über die Verteilung der Messwerte möglich ist und der Einfluss des Rauschens auf verschiedene Messgrößen individuell beurteilt werden kann. Das Simulationsszenario wird so gestaltet, dass lediglich das Bildrauschen Einfluss auf die Messung hat. Die berechneten Verteilungsbreiten lassen mit sinkendem SNR eine deutliche Zunahme erkennen, insbesondere bei der Bestimmung von Formabweichungen. Simuliert wird mit der Software aRTist 2.10 (BAM). T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Rauschen KW - Computertomografie KW - Dimensionelle Messung KW - Simulation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527144 SP - 1 EP - 11 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.V. (DGZfP) CY - Berlin AN - OPUS4-52714 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Baensch, Franziska T1 - Acoustic emission of fibre reinforced AlSi12CuMgNi alloy under compression N2 - Typically, the near-eutectic Al-Si alloys consist of highly interconnected three-dimensional network of the eutectic Silicon (Si) and intermetallics embedded into Aluminium (Al) matrix. For further improvement of the mechanical properties of such alloys, often, one single ceramic reinforcement phase, e.g. silicon carbide (SiC) or aluminium oxide (Al2O3) in the form of fibres or particles is added. However, hybrid reinforcements (fibres and particles) can further improve wear resistance and fracture toughness, and additionally, reduce anisotropy of the material. The engineering of metal matrix composites (MMC) for specific application requirements benefits from a comprehensive knowledge of the failure behaviour. Therefore, damage evolution under compression was investigated on: - pure near-eutectic AlSi12CuMgNi matrix alloy - type I: matrix reinforced with random-planar oriented Al2O3 short fibres (15 vol.%) - type II: matrix reinforced with random-planar oriented Al2O3 short fibres (7 vol.%) and additional SiC particles (15 vol.%) The analysis of damage mechanism was carried out in two rather independent but complementary studies. First, selected sister samples of every material were exposed to quasi-static compression (traverse control). The compression tests were interrupted at different strain levels. Miniature cylinders with a diameter of 1mm were extracted from the pre-strained samples and investigated by synchrotron computed tomography (SX-µCT) with a spatial resolution of about 0.7 µm. For the pure matrix alloy, microcracks are confined to the intermetallic particles and to the eutectic Si, hence no damage was observed in the Aluminium. The composite type II revealed a more effective strain accumulation (less damage) than type I at low plastic strain (up to 5 %), but a more catastrophic damage development due to cracking of the SiC clusters at higher strain levels. The second approach to study the damage initiation and accumulation in the materials subjected to compressive load was Acoustic Emission (AE) analysis. In this case the in-situ monitoring of the acoustic emission signal was performed during compression tests on specimens with dimension of several mm. For all three material types, AE activity set at 2% strain. Differences in AE behaviour of the three materials was proven based on AE hitrate, signal peak amplitudes as well as weighted peak frequencies (WPF). Future work focuses on combination of AE and SX-µCT aiming for more detailed knowledge on damage mechanism of metal matrix composites. T2 - Schall21 CY - Online meeting DA - 24.02.2021 KW - AlSi12CuMgNi KW - Al-Si alloys KW - Acoustic emission KW - Tension PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-534268 UR - https://www.dgzfp.de/seminar/schall21 AN - OPUS4-53426 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - 3D imaging and residual stress analysis of AM materials at BAM N2 - The overview of the activity of group 8.5 Micro-NDT (BAM, Belin, Germany) in the field of additively manufacturing material characterization will be presented. The research of our group is focused on the 3D imaging of AM materials by means of X-ray Computed Tomography at the lab and at synchrotron, and the residual stress characterization by diffraction (nondestructive technique). T2 - Seminar at Chalmers University and Centre for Additive Manufacture (CAM2) CY - Gothenburg, Sweden DA - 19.05.2022 KW - Additive manufacturing KW - Laser powder bed fusion KW - Residual stress KW - Computed tomography KW - Synchrotron X-ray diffraction KW - X-ray refraction PY - 2022 AN - OPUS4-55019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roveda, Ilaria T1 - Investigation of residual stresses and microstructure effects on the fatigue behaviour of a L-PBF AlSi10Mg alloy N2 - Laser Powder Bed Fusion (L-PBF) allow the fabrication of lightweight near net shape AlSi10Mg components attractive to the aerospace, automotive, biomedical and military industries. During the build-up process, high cooling rates occur. Thus, L-PBF AlSi10Mg alloys exhibit a Si-nanostructure in the as-built condition, which leads to superior mechanical properties compared to conventional cast materials. At the same time, such high thermal gradients generally involve a deleterious residual stress (RS) state that needs to be assessed during the design process, before placing a component in service. To this purpose post-process heat treatments are commonly performed to relieve detrimental RS. In this contribution two low-temperature stress-relief heat treatments (SRHT) are studied and compared with the as-built state: a SRHT at 265°C for 1 hour and a SRHT at 300°C for 2 hours. At these temperatures microstructural changes occur. In the as-built state, Si atoms are supersaturated in the α-aluminium matrix, which is enveloped by a eutectic Si-network. At 265°C the Si precipitation from the matrix to the pre-existing network is triggered. Thereafter, above 295°C the fragmentation and spheroidization of the Si branches takes place, presumably by Al–Si interdiffusion. After 2 hours the original eutectic network is completely replaced by uniformly distributed blocky particles. The effect of the heat and the microstructure modification on the RS state and the fatigue properties is investigated. Energy dispersive x-ray and neutron diffraction are combined to investigate the near-surface and bulk RS state of a L-PBF AlSi10Mg material. Differences in the endurance limit are evaluated experimentally by high cycle fatigue (HCF) tests and cyclic R-curve determination. T2 - 43rd Materials Mechanics Seminar CY - Sani, Chalkidiki, Greece DA - 05.06.2022 KW - AlSi10Mg KW - Fatigue KW - Neutron diffraction KW - X-ray diffraction PY - 2022 AN - OPUS4-55090 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schumacher, David A1 - Hohendorf, Stefan T1 - How does a Moka Pot work? 2D X-Ray video gives insights! N2 - This sequence of X-Ray images shows how one of the most common Italian moka pots actually work! The sequence starts with a completely prepared moka pot (water in the bottom part, coffee in the middle and hot plate on). During the process the water starts to boil and the steam pressure pushes the hot water through the coffee into the bassin at the top of the pot. This video sequence and additional explanations can also be found on Wikipedia. KW - X-Ray KW - Moka Pot KW - Coffee KW - Radiography KW - Espressokanne PY - 2022 DO - https://doi.org/10.5281/zenodo.7003489 PB - Zenodo CY - Geneva AN - OPUS4-55558 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - 3D Imaging and residual stress analysis of additively manufactured materials N2 - The focus of the presentation focus will be on 3D imaging by means of X-ray Computed Tomography (XCT) at the lab and at synchrotron, and the non-destructive residual stress (RS) characterization by diffraction of additively manufactured (AM) materials in BAM (Berlin, Germany). The manufacturing defects and high RS are inherent of AM techniques and affect structural integrity of the components. Using XCT the defects size and shape distribution as well as geometrical deviations can be characterized, allowing the further optimization of the manufacturing process. Diffraction-based RS analysis methods using neutron and synchrotron X-rays at large scale facilities offer the possibility to non-destructively spatially resolve both surface and bulk RS in complex components and track their changes following applied thermal or mechanical loads. T2 - The International Symposium on Nondestructive Characterization of Materials 2023 CY - Zurich, Switzerland DA - 15.08.2023 KW - Additive manufacturing KW - Residual stress KW - X-ray computed tomography PY - 2023 AN - OPUS4-58113 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - Failure Mechanisms Investigation by Means of in-situ Synchrotron Computed Tomography in Aluminum MMC-based Alloy Tailored for Additive Manufacturing N2 - Synchrotron X-ray computed tomography (SXCT) at BAMline has been paired with in-situ tensile loading to monitor damage evolution in LPBF Metal Matrix Composite (MMC) 7017 Aluminium alloy + 3 wt% Zr + 0.5 wt% TiC. The processing of the material leads formation to different categories of Zr-rich inclusions, precipitates and defects. In-situ SXCT test disclosed the critical role of the pre-cracks in the reinforcement phases in the failure mechanisms of LPBF MMC. The damage was initiated from lack-of-fusion defects and cracks propagated through coalescence with other defects. T2 - HZB Uer Meeting 2023 CY - Berlin, Germany DA - 22.06.23 KW - Additive manufacturing KW - BAMline KW - Synchrotron X-ray computed tomography KW - in-situ PY - 2023 AN - OPUS4-57801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - 3D X-ray Imaging and residual stress analysis of materials N2 - The focus of the presentation focus will be on 3D imaging by means of X-ray Computed Tomography (XCT) at the lab and at synchrotron, and the non-destructive residual stress (RS) characterization by diffraction of different kind of materials in FB8.5 Micro-NDT BAM. For instance, the manufacturing defects and high RS are inherent of additively manufacturing techniques and affect structural integrity of the components. Using XCT the defects size and shape distribution as well as geometrical deviations can be characterized, allowing the further optimization of the manufacturing process. Diffraction-based RS analysis methods using neutron and synchrotron X-rays at large scale facilities offer the possibility to non-destructively spatially resolve both surface and bulk RS in complex components and track their changes following applied thermal or mechanical loads. T2 - Seminar at Applied Materials Group at PSI CY - Villigen, Switzerland DA - 13.09.2023 KW - Additive manufacturing KW - Residual stress KW - X-ray computed tomography PY - 2023 AN - OPUS4-58310 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - Applications of x-ray computed tomography in material science N2 - The overview of the activity of Federal Institute for Material Research and Testing (BAM, Belin, Germany) in the field material characterization by X-ray imaging is presented. The principle of X-ray Computed Tomography (XCT) is explained. The multiple examples of application of quantitative analysis by XCT are reported, such as additive manufacturing, Li-ion battery, concrete research. T2 - Lecture for PhD students at Politecnico di Torino CY - Turin, Italy DA - 14.03.2024 KW - X-ray computed tomography KW - Additive manufacturing PY - 2024 AN - OPUS4-59689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tsamos, Athanasios T1 - CNN Architectures for Image Processing. N2 - Deep Convolutional Neural Networks (DCNNs) and their applications in (XCT) data conditioning and automatic segmentation. A case study in Al-Si MMCs with synthetic training data. T2 - EUROLAB-D Tagung: KI im Prüflabor: Chancen und Herausforderungen von Künstlicher Intelligenz für akkreditierte Stellen CY - Berlin, Germany DA - 14.11.2023 KW - Automatic Segmentation KW - XCT KW - Artificial Intelligence KW - Synthetic Training Data PY - 2023 AN - OPUS4-59093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tsamos, Athanasios T1 - Denoising, Deblurring and Automatic Segmentation of XCT Data with Deep Learning and Synthetic XCT Training Data. A Case Study on Al-Si MMCs. N2 - We employ in-house generated synthetic Al-Si matrix composite XCT data for training deep convolutional neural networks for XCT data conditioning and automatic segmentation. We propose an in-house multilevel deep conditioning framework capable of rectifying noise and blur in corrupted XCT data sequentially. Furthermore, for automatic segmentation, we utilize a special in-house network coupled with a novel iterative segmentation algorithm capable of generalized learning from synthetic data. We report a consistent SSIM efficiency of 92%, 99%, and 95% for the combined denoising/deblurring, standalone denoising, and standalone deblurring, respectively. The overall segmentation precision was over 85% according to the Dice coefficient. We used experimental XCT data from various scans of Al-Si matrix composites reinforced with ceramic particles and fibers. T2 - 12th International Conference on Industrial Computed Tomography (iCT2023) CY - Fürth, Germany DA - 27.02.2023 KW - Automatic Segmentation KW - Denoising Deblurring Sharpening KW - Artificial Intelligence KW - DCNNs KW - Synthetic Training Data KW - XCT PY - 2023 AN - OPUS4-59095 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Barzegar, M. A1 - Lugovtsova, Yevgeniya A1 - Bulling, Jannis A1 - Mishurova, Tatiana A1 - Pasadas, D. A1 - Ribeiro, A. A1 - Ramos, H. T1 - Automatic improved-resolution imaging of composite adhesive joints using time-frequency-wavenumber filtering applied to ultrasonic guided wavefields N2 - This paper presents an automatic damage imaging technique by employing a signal processing approach based on applying hierarchically clustered filters across different domains. The technique involves time-frequency-wavenumber filter banks which are applied sequentially to ultrasonic guided wave (UGW) data. The study is conducted for a single lap joint composite specimen with a special focus on small voids which were formed due to manual adhesive component mixing. UGW data are acquired with a 3D Scanning Laser Doppler Vibrometer (LDV) over the scan area of the bonded plate. UGWs are excited at the central frequency of 100 kHz by a single piezoelectric transducer mounted on the surface of the single plate. Within each domain of time, frequency, and wavenumber, four filters are designed which results in 64 distinct filtered wavefields. From each filtered wavefield, an image is obtained by using root-mean-square (RMS) calculation of the signals. The obtained results are then combined to create a final, improved-resolution image of the scan area. The final image is compared to the image obtained through RMS calculation of full wavefield with interpolation through Delaunay triangulation and the image obtained by X-ray radiography. The results show that the smallest void that could be detected has a diameter of 2.14 mm. T2 - 2023 IEEE International Ultrasonics Symposium (IUS) CY - Montreal, QC, Canada DA - 03.09.2023 KW - Adhesive joints KW - Ultrasonic guided waves KW - Laser Doppler vibrometer KW - Damage imaging KW - Non-destructive testing KW - Porosity analysis PY - 2023 DO - https://doi.org/10.1109/IUS51837.2023.10307423 SP - 1 EP - 4 PB - IEEE AN - OPUS4-58795 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - In-situ hot isostatic pressing combined with x-ray imaging and diffraction of laser powder bed fusion ti-6al-4v N2 - Hot Isostatic Pressing (HIP) is often introduced to tackle the porosity issue in additively manufactured (AM) materials. For instance, HIP post-processing is recommended to improve fatigue resistance of Laser powder bed fusion (PBF-LB) manufactured parts [1, 2]. Even though HIP cannot completely remove porosity, it significantly decreases the defect population and its average size below the critical threshold value leading to early crack initiation. In the present study, in-situ investigation of HIP procedure of PBF-LB Ti-6Al-4V parts was carried out to gain further insights into the densification mechanism occurring during HIP. The in-situ observations at high pressure and high temperature are uniquely possible at the PSICHE beamline of the Soleil synchrotron (France), thanks to the Ultrafast Tomography on a Paris-Edinburgh Cell (UToPEC) and the combination of the fast phase-contrast tomography and energy-dispersive diffraction [3, 4]. A detailed methodology was developed to ensure that the correct pressure and temperature were maintained during the experiments. The results allowed an estimation of the global dentification rate during HIP of PBF-LB Ti-Al-4V material, as well as a detailed quantitative characterization of the influence of pore size and shape on the densification process, thereby understanding the effectiveness of HIP process on different pore categories. After 20 mins, 75% of porosity can be considered as closed or has size below the resolution of the XCT reconstruction. We also observed that the smallest defects showed higher densification rate, while the defect shape did not have significant effect on such rate. The current development of in-situ HIP experiment allows experimental quantification and validation of the simulation work. Ultimately it paves the road to tailoring the HIP procedure for different materials depending on the porosity and microstructure. T2 - AAMS 2023 CY - Madrid, Spain DA - 26.09.23 KW - Additive manufacturing KW - HIP KW - X-ray computed tomography PY - 2023 AN - OPUS4-58482 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schade, U. T1 - Etalon effects in THz film measurements N2 - Etalon features in transmittance spectra of films arise due to the coherent superposition of waves caused by reflections multiple times at the inner film boundaries. The fringe maxima occur at i𝜆 = 2nd cos 𝜑 with i - being an integer, 𝜆 - the wavelength, d - the film thickness, 𝜑 - the angle of incidence in respect to the film normal and n - the refractive index of the film. It is obvious that such features can hinder the interpretation of absorption bands when fringe amplitude and period are in the same range as the expected bands. This poster discusses the suitability of two optical methods for the THz spectral range applied to Fourier Transform Spectroscopy. T2 - 2020 45th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) CY - Buffalo, NY, USA DA - 08.11.2020 KW - THz radiation KW - Total transmittance reflection technique PY - 2020 AN - OPUS4-56945 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana T1 - 3D imaging and residual stress analysis for AM Materials N2 - The overview of the activity of Federal Institute for Material Research and Testing (BAM, Belin, Germany) in the field of additively manufacturing material characterization will be presented. The research of our group is focused on the 3D imaging of AM materials by means of X-ray Computed Tomography at the lab and at synchrotron, and the residual stress characterization by diffraction (nondestructive technique). T2 - Seminar at Integrated Additive Manufacturing center, Politecnico Torino CY - Turin, Italy DA - 14.02.2023 KW - Additive manufacturing KW - Laser powder bed fusion KW - Residual stress KW - Computed tomography KW - Synchrotron X-ray diffraction PY - 2023 AN - OPUS4-57047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hohendorf, Stefan T1 - Medea und Jason, Eine Radiologische Untersuchung im Neuen Palais Potsdam N2 - Seit der Antike gehört die Medea-Sage zu den bekanntesten Geschichten der Weltliteratur. Der berühmte französische Künstler Carle Van Loo hat sich dieses Epos um 1759 angenommen und ein beeindruckendes Ölgemälde mit Abmessungen von 2,30x3,28m² erschaffen. Mit Mademoiselle Clairon als Medea und Henri Louis Le Kain als Jason ist ein Kunstwerk entstanden, das seitdem einige Veränderungen und Restaurierungen erfahren hat. Die Bundesanstalt für Materialforschung und -prüfung (BAM) hatte 2020 die Möglichkeit, dieses und ein zweites Kunstwerk, im Neuen Palais in Potsdam, für die Stiftung Preußische Schlösser und Gärten Berlin-Brandenburg, radiografisch zu untersuchen. Hierbei wurden sowohl technologisch als auch kunsthistorisch einige interessante Entdeckungen gemacht, die im vorliegenden Beitrag vorgestellt werden. T2 - DGZfP Jahrestatung 2022 CY - Kassel, Germany DA - 23.05.2022 KW - Röntgen KW - X-Ray KW - Kunsstechnologisch KW - Gemälde KW - Untermalung KW - Speicherfolie KW - Strahlenschutz PY - 2022 AN - OPUS4-56577 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Weise, Frank A1 - Oesch, T. A1 - Wilsch, Gerd A1 - Sigmund, S. A1 - Hünger, K.-J. A1 - Kositz, M. T1 - Analyse des gefügeabhängigen Löslichkeitsverhaltens potenziell AKR-empfindlicher Gesteinskörnungen T1 - Analysis of the microstructure depending solubility behavior of potential ASR sensitive aggregates N2 - Das gefügeabhängige Löslichkeitsverhalten wurde an folgenden vier Gesteinskörnungen unterschiedlicher Alkaliempfindlichkeitsklassen untersucht: • GK1 (EIII-S): quarzreicher Kies • GK2 (EIII-S): Grauwacke (Splitt) • GK3 (EI-S): Quarz-Feldspat-Porphyr (Splitt) • GK4 (EI-S): sandsteinreicher Kies DiePorenstrukturanalyse erfolgte sowohl an Einzelkörnern mittels vergleichender 3D-CT und BET- Untersuchungen als auch an Korngemengen der einzelnen Kornfraktionen (außer Fraktion 16/22 mm) über die Wasseraufnahme und mit BET. Für die Visualisierung und Quantifizierung der von außen zugänglichen Oberflächenanteile der Einzelkörner wurde ein Softwaretool entwickelt, erprobt und erfolgreich angewandt. Es gelang so u.a. den Nachweis zu erbringen, dass die gebrochenen Einzelkörner der Grauwacke und des Rhyoliths einen deutlich geringeren von außen zugänglichen Oberflächenanteil als die gleichartigen Gesteinskörner aus dem Kies besitzen. Aufgrund der limitierten Ortsauflösung der 3D-CT von 11 bis 16,5 μm wurde mit BET eine um drei Zehnerpotenzen höhere spezifische Oberfläche ermittelt. Zu den Porositätsuntersuchungen an den Korngemengen sei angemerkt, dass zum Teil gegenläufige Trends zwischen offener Porosität und spezifischer Oberfläche festgestellt wurden. Dieses ist beim Bezug des bei den Löseversuchen in 0,1 M KOH mit definierter NaCl-Zugabe aus der Gesteinskörnung gelösten SiO2 und Al2O3 von zentraler Bedeutung. Bei den Löseversuchen an den fraktionsspezifischen Korngemengen selbst zeigte sich, dass die stufenweise Erhöhung des NaCl-Gehalts von 0 auf 10 M.-% im Eluat eine erhöhte SiO2-Löslichkeit und eine verminderte Auslaugung von Al2O3 zur Folge hat. Auffallend war hierbei, dass die Al2O3-Löslichkeit bei GK4 ohne und mit geringer NaCl-Zugabe die mit Abstand höchsten Werte annimmt. Bei den zusätzlich durchgeführten Löseversuchen an den tomografierten Einzelkörnern in 1 M KOH-Lösung mit Zugabe von 1 M.-% NaCl zeigte sich, dass nur vereinzelt bei den untersuchten Gesteinsarten eine Korrelation zwischen dem SiO2- bzw. Al2O3-Gehalt im Eluat und der absoluten BET-Oberfläche nachweisbar ist. Dies ist vermutlich darauf zurückzuführen, dass neben der Oberfläche weitere Parameter (z.B. die mineralogische Zusammensetzung der Einzelkörner) das Löseverhalten maßgebend beeinflussen. Bei den parallel zu den Löseversuchen durchgeführten Betonversuchen nach dem ARS 04/2013 zeigte sich, dass die Alkaliempfindlichkeit der GK4 bei beiden Betonversuchen mit Alkalizufuhr unterschiedlich zu bewerten ist. So ist unabhängig von der vorgegebenen pessimalen Betonrezeptur des Fahrbahndeckenbetons ausschließlich bei der Klimawechsellagerung die GK4 als alkaliempfindlich einzustufen. Allerdings konnte der Befund der stark ausgeprägten AKR bei der GK4 mit der Dünnschliffmikroskopie nicht bestätigt werden. Analoges gilt für die Bewertung der Alkaliempfindlichkeit von GK2 mit den Betonversuchen nach der Alkalirichtlichtlinie des DAfStb. So ist auch hier die GK2 nicht im 60 °C-Betonversuch sondern ausschließlich im 40 °C-Betonversuch als alkaliempfindlich einzustufen. Dienach den verschiedenartigen Betonversuchen durchgeführten LIBS-Analysen am Vertikalschnitt der Prüfkörper zeigen, dass im Kernbereich nach dem 60 °C-Betonversuch mit 10 %iger NaCl-Lösung und nach der Klimawechsellagerung mit NaCl-Beaufschlagung annähernd gleich hohe Natrium- und Chloridgehalte vorgefunden werden. Wider Erwarten treten an den beaufschlagten Prüfflächen Abreicherungen von Natrium und Anreicherungen von Chlorid auf. Im 40°C- und 60 °C-Betonversuch wurde das Natrium bis in eine maximale Tiefe von ca. 30 mm bzw. 20 mm ausgelaugt. Die aufbauenden korrelativen Betrachtungen zwischen den Ergebnissen des 60°C Betonversuchs mit Alkalizufuhr und der Löseversuche an den fraktionsspezifischen Korngemengen in 1 M KOH-Lösung mit definierter NaCl-Zugabe sind durchaus vielversprechend. So zeigt sich beispielsweise beim Waschbeton, dass der fraktionsspezifisch gewichtete SiO2-Überschuss im Eluat nach 56 Tagen mit Zugabe von 0,5 M.-% NaCl ohne Bezug auf die BET-Oberfläche zur gleichen Einstufung der vier betrachteten Gesteinskörnungen wie bei den Dehnungen im 60 °C-Betonversuch mit 3 %-iger NaCl-Lösung führt. Außerdem korrelieren die im 60 °C-Betonversuch mit 10 %-iger NaCl-Lösung ermittelten Dehnungen mit dem gewichteten SiO2-Überschuss im Eluat bei Zugabe von 2 M.-% NaCl ohne Bezug auf die BET-Oberfläche. Ausschließlich bei den Betonversuchen nach der Alkali-Richtlinie erwies sich der Bezug des im Eluat ermittelten SiO2-Überschusses auf die BET-Oberfläche als zielführend. Aufgrund des Potenzials der Löseversuche mit NaCl-Zugabe für die Bewertung der Alkaliempfindlichkeit der Gesteinskörnung im Fahrbahndeckenbeton wird empfohlen, die vergleichenden Untersuchungen zwischen den Löseversuchen an Korngemischen der einzelnen Fraktionen und den Betonversuchen nach dem ARS 04/2013 mit einer möglichst hohen Anzahl an Gesteinskörnungen und einem präzisierten Untersuchungsumfang fortzuführen. N2 - The following four aggregates (GK) of varying grades of alkali sensitivity were examined for their microstructure-dependent solubility behavior: • GK1 (EIII-S) gravel with high quarz content • GK2 (EIII-S) greywacke (crushed stone) • GK3 (EI-S) quarz-feldspar-porphyry (crushed stone) • GK4 (EI-S) gravel with high sandstone content Pore structure analysis was carried out both on single grains using comparative 3D-CT and BET tests, and on grain samples of individual grain fractions (excluding the 16/22 mm fraction) using water absorption and BET. A software tool for visualizing and quantifying the externally accessible surfaces of single grains was developed, tested and successfully applied. This enabled us, among other things, to prove that single broken grains of greywacke and rhyolite have a much smaller externally accessible surface than grains of gravel of the same aggregate fraction. Due to the 3D-CT’s limited spatial resolution of 11 to 16.5 μm, BET was used to determine a two to three powers of ten higher specific surface. In relation to the porosity tests of the grain samples, it should be noted that in some cases, counterdirectional trends between open porosity and specific surface were determined. This is of central importance in relation to the SiO2 and Al2O3 dissolved from the aggregate in the solubility tests in 1 M KOH with defined addition of NaCl. The solubility tests on the grain samples of specific fractions showed that the gradual increase of the NaCl content in the eluate from 0 to 10 M.-% resulted in increased SiO2 solubility and reduced leaching of Al2O3. It was striking in this context that the solubility of Al2O3 in GK4 with no or little addition of NaCl gives by far the highest values. The additional solubility tests carried out on single grains, that were previously subjected to CT testing, in 1 M KOH solution with 1 M.-% added NaCl showed that in the types of aggregate examined, a correlation between the SiO2 and Al2O3 in eluate and the absolute BET surface is only occasionally demonstrable. This is probably due to the fact that solubility behavior is decisively influenced by other parameters in addition to the surface (e.g. by the mineralogical composition of individual grains). The concrete tests according to ARS 04/2013 carried out parallel to the solubility tests showed that GK4’s alkali sensitivity in both concrete tests with added alkali must be evaluated differently. For example, independent of the prescribed pessimal road surface concrete formula, GK4 can only be classified as alkali sensitive under cyclic storage. However petrographic microscopy could not confirm the findings of very marked ASR in GK4. The same applies to the evaluation of alkali sensitivity in GK2 with the concrete tests according to the German Committee for Structural Concrete (DAfStb)’s Alkali Guidelines. In this case too, GK2 should not be classified as alkali sensitive in 60 °C concrete testing, but only in 40 °C concrete testing. The LIBS analyses carried out on the vertical cross-section of the test specimens after the various concrete tests showed that almost equally high sodium and chloride levels were found in the core area after the 60 °C concrete prism test with 10 % NaCl solution and after cyclic storage with NaCl application. Contrary to expectations, the surfaces of samples after NaCl application showed a decrease in sodium and an increase in chloride. In the 40°C and 60°C concrete prism tests, sodium was depleted up to a maximum depth of approx. 30 mm and 20 mm respectively. Subsequent correlative observations between the findings of the 60°C concrete prism test with alkali application, and the solubility tests on the samples of specific grain fractions in 1 M KOH solution with defined NaCl addition, are very promising. In the case of exposed aggregate concrete, for example, the fraction-specific weighted excess SiO2 to in the eluate after 56 days with added 0.5 M.-% NaCl unrelated to the BET surface results in the same classification of the four aggregates examined as the expansions in the 60 °C concrete prism test with 3% NaCl solution. In addition, the expansions found in the 60 °C concrete prism test with 10% NaCl solution correlated with the weighted excess SiO2 in eluate with added 2 M.-% NaCl without relation to the BET surface. Only in the case of the concrete test in accordance with the Alkali Guidelines did the relationship of the excess SiO2 in the eluate to the BET surface prove to be productive. Due to the potential of the solubility test with added NaCl for the evaluation of alkali sensitivity of aggregates in road surface concrete, we recommend continuing with comparative tests between solubility tests of grain samples of the various fractions and the concrete tests in accordance with ARS O4/13 with the greatest possible number of aggregates and a precisely defined investigation scope. KW - LIBS KW - Betonfahrbahndecke KW - Alkali-Kieselsäure-Reaktion KW - Gesteinskörnung KW - Alkaliempfindlichkeit KW - 3D-CT KW - Tausalzeintrag PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:hbz:opus-bast-25832 UR - https://bast.opus.hbz-nrw.de/frontdoor/index/index/docId/2583 SN - 978-3-95606-648-1 SN - 0943-9323 VL - S 165 SP - 1 EP - 111 PB - Fachverlag NW in der Carl Ed. Schünemann KG CY - Bremen AN - OPUS4-54755 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hashemi, Seyedreza A1 - Zscherpel, Uwe T1 - Measurement of Focal Spots of X-ray Tubes Using a CT Reconstruction Approach on Edge Images of Large Holes and Comparison to Pinhole Imaging N2 - The first Non-destructive testing (NDT) method which evolved in the industrial age was radiographic testing (RT). Among all NDT methods, RT is no exception, so there are still many issues for optimizations even today. One of them is the measurement of the focal spot of X-ray tubes. The size of the focal spot is critical for imaging, because it determines the spatial resolution in the X-ray image. The classical way to evaluate focal spots of X-ray tubes is by pinhole imaging using a camera obscura. But this method has a natural lower limit, which is defined by the diameter of the pinhole used (today min. 10 µm). Therefore, focal spot sizes lower than 50 µm diameter cannot be imaged and measured correctly. An alternative approach, which permits this, was investigated here using the edge unsharpness of holes much larger than the focal spot size. The results of both methods were compared using 3 different X-ray tubes. KW - Reconstruction method KW - Radiographic testing (RT) using X-rays KW - Focal spot measurement KW - Edge unsharpness KW - X-ray tubes KW - Pinhole imaging KW - Computed Tomography (CT) KW - Focal Spot (FS) PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-608646 DO - https://doi.org/10.58286/29556 SN - 2941-4989 SP - 1 EP - 9 PB - NDT.net CY - Berlin, Germany AN - OPUS4-60864 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reuter, T. A1 - Borges de Oliveira, F. A1 - Abt, Ch. A1 - Ballach, F. A1 - Bartscher, M. A1 - Bellon, Carsten A1 - Dennerlein, F. A1 - Fuchs, P. A1 - Günnewig, O. A1 - Hausotte, T. A1 - Hess, J. A1 - Kasperl, S. A1 - Maass, N. A1 - Kimmig, W. A1 - Schielein, R. A1 - von Schmid, M. A1 - Suppes, A. A1 - Wagner, G. A1 - Watzl, Ch. A1 - Wohlgemuth, F. T1 - Introduction to “Realistic Simulation of real CT systems with a basic-qualified Simulation Software - CTSimU2“ N2 - The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin". T2 - 12th Conference on Industrial Computed Tomography (iCT) 2023 CY - Fürth, Germany DA - 27.02.2023 KW - dXCT KW - X-ray computed tomography KW - Simulation PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-589204 DO - https://doi.org/10.58286/27715 VL - 28 IS - 3 SP - 1 EP - 5 PB - NDT.net AN - OPUS4-58920 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reuter, T. A1 - Wohlgemuth, F. A1 - Bellon, Carsten A1 - Hausotte, T. T1 - Measurement-based Detector Characteristics for Digital Twins in aRTist 2 N2 - Various software products for the simulation of industrial X-ray radiography have been developed in recent years (e.g., aRTist 2, CIVA CT, Scorpius XLab, SimCT, Wilcore) and their application potential has been shown in numerous works. However, full systematic approaches to characterise a specific CT system for these simulation software products to obtain a truthful digital twin are still missing. In this contribution, we want to present two approaches to obtain realistic grey values in X-ray projections in aRTist 2 simulations based on measured projections. In aRTist 2, the displayed grey value of a pixel is based on the energy density incident on that pixel. The energy density is calculated based on the X-ray tube spectrum, the attenuation between source and detector as well as an energy-dependent sensitivity curve of the detector. The first approach presented in this contribution uses the sensitivity curve as a free modelling parameter. We measured the signal response at different thicknesses of Al EN-AW6082 at different tube voltages (i.e., different tube spectra). We then regarded the grey values displayed by these projections as a data regression respectively an optimisation problem and obtained the sensitivity curve that is best able to reproduce the measured behaviour in aRTist 2. The resulting sensitivity curve does not necessarily hold physical meaning but is able to simulate the real system behaviour in the simulation software. The second approach presented in this contribution is to estimate the sensitivity curve based on assumptions about the characteristics of the scintillation detector (e.g., scintillator material, scintillator thickness and signal processing characteristics). For this approach, a linear response function (linear relationship between the deposited energy per pixel and the resulting grey value) is assumed. If the detector characteristics, which affect the simulated deposited energy, are properly modelled, the slope and offset of the response function to match the measured grey values should be the same for different tube spectra. As the offset is constant and given by the grey values measured at no incident radiation, the slope is the remaining parameter to evaluate the success of the detector modelling. We therefore adapted the detector characteristics by changing the detector setup until the slope was nearly the same for all measured tube spectra. We are aware that the resulting parameters of the scintillator material and thickness might not be the real ones, but with those modelling parameters we are able to simulate realistic grey values in aRTist 2. Both of those approaches could potentially be a step forward to a full systematic approach for a digital twin of a real CT system in aRTist 2. T2 - 20th World Conference on Non-Destructive Testing (WCNDT 2024) CY - Incheon, South Korea DA - 27.05.2024 KW - Digital Twin KW - Computed Tomography KW - Simulation PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-602046 DO - https://doi.org/10.58286/29910 SP - 1 EP - 10 PB - NDT.net CY - Mayen, Germany AN - OPUS4-60204 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hille, Falk A1 - Nerger, Deborah A1 - Moosavi, Robabeh A1 - Grunwald, Marcel T1 - Discussion on data evaluation of tomographic and numerical results N2 - The contribution discusses the processing and analysis of data generated on two different ways of investigations for impact damage in reinforced concrete structures. Damage investigations are essential to determine type and characteristics of damage and thus the residual capacity. Damage describing data is generated using two different types of investigation, a non-destructive tomographic as well as numerical examination. Subsequently, data of both sources was merged and analysed. Within the research project “Behaviour of structural components during impact load conditions caused by aircraft fuel tank collision” reinforces concrete plates were damaged by impact loading, see Hering (2020). Afterwards the damaged specimens were investigated tomographically as well as numerically using several methods and models. Aim of the presented research work was to specify an objective comparability of numerical data with experimentally determined damage patterns and based on this, to establish a quantitative damage evaluation. T2 - 26th International Conference on Structural Mechanics in Reactor Technology CY - Potsdam, Germany DA - 10.07.2022 KW - Impact damage on reinforced concrete KW - Tomographic damage evaluation KW - Numerical damage simulation PY - 2022 SP - 1 EP - 8 AN - OPUS4-55474 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hille, Falk T1 - Discussion on data evaluation of tomographic and numerical results N2 - The contribution discusses the processing and analysis of data generated on two different ways of investigations for impact damage in reinforced concrete structures. Damage investigations are essential to determine type and characteristics of damage and thus the residual capacity. Damage describing data is generated using two different types of investigation, a non-destructive tomographic as well as numerical examination. Subsequently, data of both sources was merged and analysed. Within the research project “Behaviour of structural components during impact load conditions caused by aircraft fuel tank collision” reinforces concrete plates were damaged by impact loading, see Hering (2020). Afterwards the damaged specimens were investigated tomographically as well as numerically using several methods and models. Aim of the presented research work was to specify an objective comparability of numerical data with experimentally determined damage patterns and based on this, to establish a quantitative damage evaluation. T2 - 26th International Conference on Structural Mechanics in Reactor Technology CY - Potsdam, Germany DA - 10.07.2022 KW - Impact damage of reinforced concrete KW - Tomographic damage evaluation KW - Numerical simulation of impact damage PY - 2022 AN - OPUS4-55476 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hering, Marcus A1 - Fiedler, Georg T1 - Investigation of multiple impact-damaged reinforced concrete structures as a reference for liquid penetration behavior and tomographic studies N2 - The structural integrity of outer reinforced concrete (RC) containments of nuclear power plants provides an essential shield against external hazards. If this containment is damaged by an impact event, such as an aircraft crash, the question arises to which degree the reinforced concrete containment still has its protective capability. This concerns both purely structural protection and protection against liquids penetrating the interior of the containment. Due to the dimensions of the containment structures, it is difficult to perform real scale impact experiments, so in the past decades plate geometries at medium scale have been used for investigations. Detailed investigations on the structural behaviour of RC members or RC plates subjected to impact loading have already been presented in Just et al., Hering, Hering et al., Bracklow et al., Hille et al. and Nerger et al. The following investigations deal with the single and multiple impact event (first hard impact and/or subsequent soft impact) on a RC specimen, which provides the basis for further investigations. A description of the test setup and the test procedure as well as a presentation of the test results from the impact tests are provided. Furthermore, the experimental program is presented, which the damaged RC specimens are to undergo to deal with the question of how much the impact-damaged RC structure has become permeable to liquid media, such as water and kerosene, depending on the intensity of the impact. The aim of these following investigations is to develop a test setup that can be applied to investigate the liquid penetration behaviour (LPB) of small, medium, and large-scale RC members. In addition to the liquid penetration experiments, the damaged specimens are to be examined by planar tomography to obtain the damage inside the specimen. The combination of damaging event, fluid penetration behaviour and tomography should enable a comprehensive understanding of the damage to the RC specimen. T2 - Conference: 27th International Conference on Structural Mechanics in Reactor Technology (SMiRT) CY - Yokohama, Japan DA - 04.03.2024 KW - Drop Tower KW - Hard Impact KW - Multiple Impact KW - Soft Impact PY - 2024 AN - OPUS4-61991 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bircher, B. T1 - Compensation of machine geometry deviations for dXCT N2 - It is fundamental to determine the machine geometry accurately for dimensional X-ray computed tomography (XCT) measurements. When performing high-accuracy scans, compensation of a non-static geometry, e.g. due to rotary axis errors or drift, might become necessary. Here we provide an overview of methods to determine and account for such deviations on a per projection basis. They include characterisation of stage error motions, in situ geometry measurements, numerical simulations, and reconstruction-based optimization relying on image quality metrics and will be discussed in terms of their metrological performance. Since a radiographic calibration is always required to provide an initial absolute geometry, this method will be presented as well. T2 - dXCT conference 2021 CY - Online meeting DA - 17.05.2021 KW - Computed tomography PY - 2021 AN - OPUS4-54029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Binder, F. T1 - Ein praxisnaher Leitfaden für computertomografische Untersuchungen mit der radiografischen Simulationsumgebung aRTist N2 - Radiografische Simulationswerkzeuge wie aRTist, ScorpiusXLab, SimCT oder CIVA CT verwenden analytische Methoden und physikalische Monte-Carlo-Teilchentransportsimulationen, um die Interaktionsprozesse zwischen Röntgenstrahlung und Materie zu simulieren. Die berechneten Projektionen bilden anschließend unter Berücksichtigung einer definierten Scan-Trajektorie die Basis der Simulation einer röntgencomputertomografischen Untersuchung. Radiografische Simulationswerkzeuge befinden sich in einem stetigen Wandel, beispielsweise durch die Entwicklung neuer Rekonstruktionsmethoden, durch Erweiterung von analytischen Modellen, durch Integration komplexer Trajektorien oder durch Berücksichtigung von prozessbedingten geometrischen Abweichungen. Im laufenden EMPIR-Projekt „AdvanCT“ entsteht deshalb ein „Good Practice Guide“ für die Simulationsumgebung aRTist. Ziel dieses Guides ist es, die mit steigender Komplexität verbundenen Einstiegshürden für Anwender von aRTist zu reduzieren, um damit einen praxisnahen Zugang zur virtuellen Computertomografie zu ermöglichen. Dabei werden anhand von praktisch nachvollziehbaren Beispielen die grundlegenden Mechanismen der Simulationsumgebung erklärt und ein strukturierter Leitfaden zur Simulation röntgencomputertomografischer Untersuchungen mit aRTist vermittelt. In diesem Beitrag werden erste Auszüge des Guides sowie eine Übersicht der weiteren geplanten Themen für die anschließende Diskussion vorgestellt. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Computertomographie Simulation PY - 2021 AN - OPUS4-54030 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Virtual CT with aRTist N2 - Simulation becomes more and more important in modern CT imaging. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for educational purposes. The radiographic simulator aRTist is a modelling tool which simulates X-ray imaging using a hybrid analytical and Monte Carlo method to efficiently model the radiation transport. In addition to the relevant physical effects such as absorption, scattering and fluorescence, simplified fast models are employed to describe the characteristics of the X-ray source and the detector. aRTist is well equipped to model realistic X-ray imaging setups due to the ability to load exported CAD object descriptions. A simple CT scan module is contained in aRTist which allows the simulation of standard (circular cone beam) scanning trajectories. This training session starts with a general introduction to aRTist and will highlight its basic usage. Furthermore, the focus is on the configuration of scan trajectories and batch simulations for virtual CT. The aim is to enable the audience to use the aRTist software for their own experiments in virtual CT. T2 - dXCT conference 2021 CY - Online meeting DA - 17.05.2021 KW - computed tomography simulation PY - 2021 AN - OPUS4-54062 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Borges de Oliveira, F. A1 - Reuter, T. A1 - Plotzki, David A1 - Bartscher, M. A1 - Hausotte, T. T1 - Novel reference standards for the qualification of radiography-based computed tomography simulation software N2 - This contribution presents a set of largely novel reference standards specially designed for testing different important physical effects and functionalities of radiography-based computed tomography (CT) simulation software. These standards were developed within the scope of the German cooperation project “CTSimU – Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation” [1] and serve as tools for the basic qualification of the sufficient physical correctness and required features of simulation software of CT-based coordinate measurement systems (CMSs) via the analyses either of 2D projection images only or of full CT scans. The results serve as input to the German standardisation committee for the development of a new national VDI/VDE guideline in the series VDI/VDE 2630 dealing with the basic qualification aspect of CT simulation software and shall lay ground for the measurement uncertainty determination of dimensional measurements using CT. T2 - 11th Conference on Industrial Computed Tomography (iCT 2022) CY - Online meeting DA - 08.02.2022 KW - Multi-geometry cuboid KW - Radiographic simulation software KW - Basic qualification KW - CT simulation, spherical step-wedge KW - Conical hole sheet KW - Tungsten-Edge PY - 2022 SP - 1 EP - 12 PB - Research Group Computed Tomography, Upper Austrian University of Applied Sciences (FH OÖ) CY - Wels, Austria AN - OPUS4-54569 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bircher, B. A1 - Meli, F. A1 - Küng, A. A1 - Bellon, Carsten A1 - Evsevleev, Sergei A1 - Katic, M. A1 - Heikkinen, V. A1 - Hemming, B. A1 - Lassila, A. T1 - Traceable determination of non-static XCT machine geometry: New developments and case studies N2 - It is fundamental to determine the machine geometry accurately for dimensional X-ray computed tomography (XCT) measurements. When performing high-accuracy scans, compensation of a non-static geometry, e.g. due to rotary axis errors or drift, might become necessary. Here we provide an overview of methods to determine and account for such deviations on a per projection basis. They include characterisation of stage error motions, in situ geometry measurements, numerical simulations, and reconstruction-based optimization relying on image quality metrics and will be discussed in terms of their metrological performance. Since a radiographic calibration is always required to provide an initial absolute geometry, this method will be presented as well. The improvements of the XCT geometry correction methods are presented by means of case studies. The methods can be applied individually or in combination and are intended to provide a toolbox for XCT geometry compensation. T2 - 11th Conference on Industrial Computed Tomography (iCT 2022) CY - Online meeting DA - 08.02.2022 KW - Radiographic XCT geometry determination KW - Dimensional metrology KW - traceability KW - XCT machine geometry KW - Calibrated reference standards PY - 2022 SP - 1 EP - 10 PB - Research Group Computed Tomography, Upper Austrian University of Applied Sciences (FH OÖ) CY - Wels, Austria AN - OPUS4-54479 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Plotzki, David A1 - Hartlaub, Bendix A1 - Borges de Oliveira, F. A1 - Reuter, T. A1 - Wohlgemuth, F. A1 - Bellon, Carsten A1 - Hausotte, T. T1 - The CTSimU software toolbox for CT-related image processing and quality assessment N2 - A software toolbox is introduced that addresses several needs common to computed tomography (CT). Built for the WIPANO CTSimU project to serve as the reference implementation for its image processing and evaluation tasks, it provides a Python 3 interface that is adaptable to many conceivable applications. Foremost, the toolbox features a pipeline architecture for sequential 2D image processing tasks, such as flat field corrections and image binning, and enables the user to create their own processing modules. Beyond that, it provides means to measure line profiles and image quality assessment algorithms to calculate modulation transfer functions (MTF) or to determine the interpolated basic spatial resolution (iSRb) using a duplex wire image. It can also be used to calculate projection matrices for the reconstruction of scans with arbitrary industrial CT geometries and trajectories. The CTSimU project defined a framework of projection- and volume-based test scenarios for the qualification of radiographic simulation software towards its use in dimensional metrology. The toolbox implements the necessary evaluation routines and generates reports for all projection-based tests. T2 - 11th Conference on Industrial Computed Tomography (iCT 2022) CY - Online meeting DA - 08.02.2022 KW - Image processing KW - CT KW - Geometry KW - Software KW - Python PY - 2022 SP - 1 EP - 7 PB - Research Group Computed Tomography, Upper Austrian University of Applied Sciences (FH OÖ) CY - Wels, Austria AN - OPUS4-54476 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reuter, T. A1 - Borges de Oliveira, F. A1 - Plotzki, David A1 - Hausotte, T. T1 - Influence of detector misalignments on different geometrical and dimensional measurands using a dedicated test specimen N2 - An important focus of research in Industrial X-ray Computed Tomography (CT) is to determine the task-specific measurement uncertainty of CT measurements numerically by using simulations. For this, all relevant influence factors need to be identified and quantified. It is known, for example, that geometrical misalignments of the detector lead to measurement deviations if the reconstruction does not consider these misalignments. This contribution uses computer simulation of CT data to investigate the influence of geometrical misalignments of the detector on several measurands found in typical measurements tasks in the industry. A newly developed test specimen with a broad variety of features is used for this study. Angular and positional detector deviations are systematically introduced into the simulations and deliberately left uncompensated during the CT reconstruction. The resulting measurement deviations are shown and discussed. T2 - 11th Conference on Industrial Computed Tomography (iCT 2022) CY - Online meeting DA - 08.02.2022 KW - Geometrical misalignment KW - Task specific numerical measurement uncertainty KW - Dimensional metrology PY - 2022 SP - 1 EP - 7 PB - Research Group Computed Tomography, Upper Austrian University of Applied Sciences (FH OÖ) CY - Wels, Austria AN - OPUS4-54568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Oesch, Tyler T1 - Analysis of the porosity of alkali-sensitive aggregates for the assessment of microstructure-dependent solubility in the context of ASR N2 - Intensified Alkali-Silica Reaction (ASR) damage has occurred on German roadways in recent years, leading to requirements for compulsory pre-construction investigation of aggregate alkali sensitivity using concrete tests with external alkali supply. However, since these tests are time-consuming and cost-intensive, there is interest in replacing them with a solubility test on pure aggregate in 0.1 M KOH solution at 80°C with a defined NaCl content (1wt.-%). In this context, the influence of aggregate pore structure on SiO2 and Al2O3 solubility was investigated in this project. This paper compares the results of porosity studies with X-ray Computed Tomography (3D-CT) and the Brunauer-Emmett-Teller (BET) method on individual quarried and river gravel granules of both rhyolite and greywacke. For visualization and quantification of both externally accessible and fully enclosed surfaces of granules using X-ray 3D-CT, special software tools were developed. The results demonstrated that the river gravel granules had significantly larger externally accessible surfaces than the quarried granules. BET measurements on individual stones showed, as expected, that measured surfaces were about three orders of magnitude larger than those from the X-ray 3D-CT analyses due to the higher spatial resolution of BET. There was no apparent correlation between the X-ray 3D-CT and BET surface areas. Mercury porosimetry measurements indicate that this may be due to the presence of significant porosity below the spatial resolution of the X-ray 3D-CT. A comparison of SiO2 and Al2O3 solubility measurements with the X-ray 3D-CT and BET surface area data resulted only in weak, inconclusive correlations, indicating the need for further experimental investigation. T2 - Microdurability Webinar CY - Online meeting DA - 12.10.2020 KW - X-ray Computed Tomography (CT) KW - Brunauer-Emmett-Teller (BET) Method KW - Alkali-Silica Reaction (ASR) KW - Porosity KW - Solubility PY - 2020 AN - OPUS4-51429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Karapanagiotis, Christos T1 - Structural health monitoring of hydrogen pressure vessels using distributed fiber optic sensing N2 - We report on distributed fiber optic sensing-based monitoring of hydrogen composite overwrapped pressure vessels (COPV) to simultaneously increase the operational lifespan and mitigate maintenance costs. Our approach represents, to the best of our knowledge, the first application of distributed fiber optic sensing for COPV Type IV monitoring, where the sensing fibers are attached to the surface, rather than integrated into the composite material. Specifically, we attach an optical fiber of 50 m to the pressure vessel's surface, covering both the cylindrical and dome sections. We note that our fiber optic sensing technique relies on swept wavelength interferometry providing strain information along the entire length of the optical fiber with high spatial resolution even at the millimeter scale. When the vessel is pressurized, the sensing optical fiber shows a linear strain response to pressure at every position along the fiber. After thousands of load cycles, the vessel finally fails with the optical fiber detecting and precisely localizing the damage in the vessel’s blind dome area. Furthermore, we discuss the potential of state-of-the-art signal processing methods and machine learning for advancing predictive maintenance. This could reduce the number of regular inspections, mitigate premature maintenance costs, and simultaneously increase the vessel’s remaining safe service life. We believe that the structural health monitoring of hydrogen pressure vessels with fiber optic sensors can enhance trust in hydrogen technology contributing to the energy transition in the future. T2 - 11th European Workshop on Structural Health Monitoring CY - Potsdam, Germany DA - 10.06.2024 KW - Hydrogen KW - Composites KW - Pressure vessels KW - Fiber optic sensors KW - Machine learning KW - Structural health monitoring PY - 2024 AN - OPUS4-60275 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Evans, Alexander T1 - Introduction to AGIL N2 - An introduction to the Themenfeld Material project AGIL will be presented. The concept of the project, the work package structure and the material used within the project will be presented. T2 - 2nd Workshop on In situ Monitoring and Microstructure Development in Additive Manufacturing CY - Online meeting DA - 19.04.2021 KW - AGIL KW - Ageing KW - Additive manufacturing KW - Laser powder bed fusion PY - 2021 AN - OPUS4-54107 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Binder, F. A1 - Bellon, Carsten A1 - Wohlgemuth, F. A1 - Hausotte, T. T1 - Ein praxisnaher Leitfaden für computertomografische Untersuchungen mit der radiografischen Simulationsumgebung aRTist N2 - Radiografische Simulationswerkzeuge wie aRTist, ScorpiusXLab, SimCT oder CIVA CT verwenden analytische Methoden und physikalische Monte-Carlo-Teilchentransportsimulationen, um die Interaktionsprozesse zwischen Röntgenstrahlung und Materie zu simulieren. Die berechneten Projektionen bilden anschließend unter Berücksichtigung einer definierten Scan-Trajektorie die Basis der Simulation einer röntgencomputertomografischen Untersuchung. Für den erfolgreichen Einsatz der Computertomografie, sei es als zerstörungsfreie Prüfmethode oder beim dimensionellen Messen, ist es generell notwendig, bekannte Fehler- bzw. Abweichungsquellen des Messverfahrens auszuschließen oder zu reduzieren. Dabei hat sich gezeigt, dass die Auswahl der Messparameter und die Erfahrung des Anwenders direkten Einfluss auf das erzielbare Messergebnis einer computertomografischen Untersuchung nehmen. Es ist daher sinnvoll, die Parameterauswahl in einem virtuellen Simulationsaufbau vorher zu erproben und an die Messaufgabe anzupassen. Neben der Optimierung von Messparametern finden radiografische Simulationswerkzeuge auch Anwendung für Machbarkeitsstudien und werden zur Schulung von Anwendern im Bereich der Röntgen-Computertomografie verwendet. Radiografische Simulationswerkzeuge befinden sich in einem stetigen Wandel, beispielsweise durch die Entwicklung neuer Rekonstruktionsmethoden, durch Erweiterung von analytischen Modellen, durch Integration komplexer Trajektorien oder durch Berücksichtigung von prozessbedingten geometrischen Abweichungen. Im laufenden EMPIR-Projekt „AdvanCT“ entsteht deshalb ein „Good Practice Guide“ für die Simulationsumgebung aRTist. Ziel dieses Guides ist es, die mit steigender Komplexität verbundenen Einstiegshürden für Anwender von aRTist zu reduzieren, um damit einen praxisnahen Zugang zur virtuellen Computertomografie zu ermöglichen. Dabei werden anhand von praktisch nachvollziehbaren Beispielen die grundlegenden Mechanismen der Simulationsumgebung erklärt und ein strukturierter Leitfaden zur Simulation röntgencomputertomografischer Untersuchungen mit aRTist vermittelt. In diesem Beitrag werden erste Auszüge des Guides sowie eine Übersicht der weiteren geplanten Themen für die anschließende Diskussion vorgestellt. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Computertomografie KW - Simulation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530476 UR - https://jahrestagung.dgzfp.de/portals/jt2021/bb176/inhalt/poster.htm SN - 978-3-947971-18-3 VL - 176 SP - 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-53047 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reuter, T. T1 - Vorstellung des Projektes CTSimU2 Realistische Simulation realer Röntgencomputertomografie-Systeme mit basisqualifizierter Simulationssoftware N2 - Die Entwicklung von Werkzeugen zur realitätsnahen Nachbildung eines industriellen CT-Systems in einer Simulationssoftware ist derzeit Hauptaufgabe des WIPANO Forschungsprojektes CTSimU2 Realistische Simulation realer Röntgencomputertomografie - Systeme mit basisqualifizierter Simulationssoftware. Als Voraussetzung dienen dabei Simulationssoftwares, die durch das Testframework aus dem Vorprojekt CTSimU1 basisqualifiziert wurden. Das Testframework testet die hinreichende physikalische Korrektheit und Funktionalität einer Simulationssoftware (Basisqualifizierung der Software). Für eine realitätsnahe Nachbildung ist nicht nur die Güte der Simulationssoftware, sondern insbesondere die Güte der Parametrisierung des realen CT-Systems in der Simulationssoftware ausschlaggebend. Dabei kann das Vorgehen der Parametrisierung in vier Schritte unterteilt werden: die Datenaufnahme am realen CT-System (Schritt 1), die Auswertung der aufgenommenen Daten für die Generierung allgemeiner Parameterangaben (Schritt 2), die Übertragung der Parameter in die spezifischen Simulationssoftwares (Schritt 3) und die Validierung der resultierenden Simulationsparameter durch einen geeigneten Test (Schritt 4). Ziel des Projektes ist es daher neben der Erarbeitung eines Werkzeugkastens mit allgemeinen Methoden zur Datenaufnahme und Auswertung der Daten, die Entwicklung eines Tests, auf dessen Basis die ausreichend korrekte Simulation einer realen Anlage beurteilt werden kann. Die erarbeiteten Ergebnisse sollen wie bereits im Vorprojekt CTSimU1 in einen Richtlinienentwurf für die Richtlinienreihe VDI/VDE 2630 übertragen werden. Dieser Beitrag soll einen Überblick über das Projekt und die ersten Ergebnisse geben. T2 - DGZfP Jahrestagung 2023 CY - Friedrichshafen, Germany DA - 15.05.2023 KW - XCT KW - Simulation PY - 2023 UR - https://www.ndt.net/?id=28620 AN - OPUS4-58922 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Realistic Simulation of CT Systems - An Introduction to The CTSimU2 Project N2 - The project series CTSimU was initiated with the goal to develop a set of procedures to enable the determination of the task-specific measurement uncertainty of a CT system numerically by radiographic simulation. The first project (2019-2022) “Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU” was focused on the sufficient physical correctness of the radiographic simulation and created as a result a test framework for simulation softwares and a draft of a VDI standard in the series VDI/VDE 2630 for this application. However, for the realistic simulation of a CT system in a simulation software (i.e. a digital twin), not only the correctness of the simulation software itself is crucial, but also the quality of the parameterization of the CT system in the simulation software - this represents the starting point of the 2nd project “Realistic Simulation of real CT systems with a basic-qualified Simulation Software - CTSimU2” (2022-2024). The parameterization of a CT system in a simulation software can be divided into four steps: after the data acquisition at the real CT system (step 1) follows the evaluation of the acquired data for the generation of general parameter specifications (step 2). It follows the transfer of the parameters into the specific simulation software (step 3) and the validation of the resulting simulation parameters by a suitable test (step 4). The intended result of the project CTSimU2 is a draft VDI standard (for VDI/VDE 2630) for this test, which contains an informative annex on the state of the art regarding the possibilities for parameter determination. T2 - 13th European Conference on Non-Destructive Testing (ECNDT) CY - Lisbon, Portugal DA - 03.07.2023 KW - X-ray computed tomography KW - dXCT KW - Simulation PY - 2023 AN - OPUS4-58923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Virtual CT with aRTist N2 - The software aRTist is a simulation tool for the generation of realistic radiographs of virtual radiographic superstructures. With radiographic simulations, virtual component models can be scanned as in a computer tomograph. Industrial X-ray computed tomography (CT) enables the non-destructive detection of internal and external surfaces as well as inhomogeneities of technical objects. Virtual CT offers new possibilities for the investigation of parameter influences of this complex testing and measuring technique. In addition to the option of switching physical effects on and off, scanning movements can also be tested before their technical realization. The virtual CT generates projection images from different directions for the subsequent reconstruction of a volume model of the examined object. The reconstruction of the simulated scans is carried out with the algorithms and programs for real scans. Tomographic scans consist of a large number of projections, which practically cannot be generated individually by the user of a simulation. The software offers various options for the automated simulation of tomographic scans. These range from standard CT to scans on free trajectories or with individual projection matrices. T2 - 12th Conference on Industrial Computed Tomography (iCT) 2023 CY - Fürth, Germany DA - 27.02.2023 KW - X-ray computed tomography KW - Simulation PY - 2023 AN - OPUS4-58919 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bellon, Carsten T1 - Virtuelle CT N2 - Das Computerprogramm aRTist ist ein praktisches Simulationswerkzeug zur Erzeugung realistischer Radiographien virtueller Durchstrahlungsaufbauten. Mit Durchstrahlungssimulationen können Bauteile, repräsentiert durch STL-Geometrien, wie in einem Computertomografen gescannt werden. Dabei werden verschiedenste Parameter gezielt und exakt berücksichtigt. Die Virtuelle Computertomografie bietet neue Möglichkeiten der Untersuchung von Parametereinflüssen. Neben der Möglichkeit, physikalische Effekte an- und abzuschalten, z.B. die Streustrahlung, können auch Scanbewegungen getestet werden, bevor diese technisch realisiert werden. Das für die Forschung entwickelte Simulationsprogramm aRTist bietet mit seiner intuitiven grafischen Benutzeroberfläche vielfältige Anwendungsmöglichkeiten auch in Praxis und Entwicklung, beispielsweise zur Parameteroptimierung, für Machbarkeitsstudien oder zur Abschätzung der Unsicherheit dimensioneller Messungen. KW - Vituelle Computertomographie Simulation PY - 2020 SN - 2199-8299 VL - 2020 IS - April SP - 50 EP - 51 PB - TeDo Verlag GmbH CY - Marburg AN - OPUS4-50691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - AdvanCT Virtual CT N2 - Simulation becomes more and more important in modern CT imaging. It is increasingly used to optimize techniques for complex applications, and for educational purposes. Simulation can also be used for uncertainty estimation of dimensional CT measurements. The radiographic simulator aRTist is a modelling tool which simulates X-ray imaging using a hybrid analytical and Monte-Carlo method to efficiently model the radiation transport. In addition to the relevant physical effects such as absorption and scattering, simplified fast models are employed to describe the characteristics of the X-ray source and the detector. aRTist is well equipped to model realistic X-ray imaging setups due to the ability to load exported CAD object descriptions. By repetitive simulation runs aRTist can function as virtual CT device. A simple CT scan module is contained in aRTist which allows the simulation of standard (circular cone beam) scanning trajectories. AdvanCT is a module for aRTist which allows to set up more complex scanning trajectories by attaching geometrical modification functions to the objects in the radiographic scene. In this way, advanced scanning modes can be realized. In addition to deterministic motion, also random variations can be introduced. By combining random variations with deterministic motion, non-ideal (realistic) CT scan geometries can be simulated, e.g. focal spot drift and mechanical instability of the axis of rotation. The AdvanCT module conveniently allows to construct these scenarios in a graphical interface and provides a preview before starting the (potentially long running) batch job. Therefore, deviations from ideal CT scan trajectories can be easily adjusted which is a necessary step towards uncertainty determination from simulation. T2 - dXCT conference 2021 CY - Online meeting DA - 17.05.2021 KW - X-ray Virtual Computer Tomography Simulation PY - 2021 AN - OPUS4-52953 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - CTSimU — Durchstrahlungssimulation für die Messunsicherheitsbestimmung beim Messen geometrischer Merkmale mittels Röntgen- Computertomographie N2 - Die industrielle Röntgen-Computertomographie (CT) ist in der geometrischen Messtechnik die einzige Technologie, die sowohl innen- als auch außenliegende Merkmale eines Werkstücks mit einer Messung zerstörungsfrei messen kann. Die Güte der Messung kann mittels einer dem Messwert beigeordneten Messunsicherheit angegeben werden. Allerdings sind zur Ermittlung der Messunsicherheit für eine Messgröße einer CT-Messung nach Stand der Technik (VDI/VDE 2630 Blatt 2.1) zwanzig Wiederholmessungen an kalibrierten Werkstücken notwendig. Da die Messung mit realen CT-Messgeräten zeit- und kostenintensiv ist, wird analog zur taktilen Koordinatenmesstechnik eine numerische Messunsicherheitsbestimmung durch Simulation angestrebt (vgl. VDI/VDE 2617 Blatt 7, GUM Supplement 1). Die Simulation bietet den Vorteil, dass sie sowohl zeitsparend als auch kosten- und ressourceneffizient ist. Allerdings ist die Zuverlässigkeit der verschiedenen Simulationsumgebungen momentan nicht quantifizierbar. Für eine glaubwürdige Anwendung von Simulationsumgebungen für die Messunsicherheitsbestimmung benötigen Anwender eine Beurteilung derselben – auch um eine Norm- bzw. Richtliniensicherheit in der Praxis sicherzustellen. Das Ziel dieses Projekts ist es daher, einen Richtlinienentwurf VDI/VDE 2630 Blatt 2.2 „Basisqualifizierung von Softwaresystemen für die Simulation geometrischer Messungen mit Röntgen-Computertomografie“ zu erstellen. Auf dieser Basis soll es möglich sein, die Eignung von Simulationsumgebungen zur Ermittlung der aufgabenspezifischen Messunsicherheit zu bewerten. Dazu wird ein Testframework entwickelt, mit welchem Durchstrahlungssimulationssoftwares basisqualifiziert werden können. Das Projekt wird in der Förderrichtlinie WIPANO durch das Bundesministerium für Wirtschaft und Energie gefördert. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Computertomographie Simulation PY - 2021 AN - OPUS4-52753 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von Rüden, H. T1 - Röntgen-Computertomographie (CT) für die Kulturguterhaltung N2 - Als bildgebendes und zerstörungsfreies Verfahren eignet sich die Röntgen-Computertomographie (CT) insbesondere bei der Untersuchung von Kunst- und Kulturgütern. Die für Werkstoffprüfung und Materialanalyse konzipierten CT-Anlagen bieten dank hoher Röntgenleistung die Möglichkeit zusätzlich zu Holz, Keramiken und Kunststoffen auch stark schwächende Materialien, wie bspw. Metalle, zu durchdringen. Für eine hohe räumliche Auflösung im unteren Mikrometerbereich (2-200µm) sorgen entsprechend ausgelegte CT-Anlagen. In der Bundesanstalt für Materialforschung und -prüfung (BAM) stehen mehrere solcher CT-Anlagen für unterschiedliche Fragestellungen sowie Probengrößen und - materialien zur Verfügung. Einige Beispiele aus den vergangenen Arbeiten der BAM veranschaulichen das große Potential dieser Untersuchungsmethode. Da bei einer CT-Messung in der Regel das gesamte Untersuchungsobjekt erfasst und in ein digitales Volumenmodell überführt wird, eröffnet sich für Archäologen und Restoratoren die Möglichkeit Untersuchungen hinsichtlich Materialzusammensetzung, Erhaltungszustand und Herstellungstechnik am virtuellen Objekt vorzunehmen, ohne die Originalsubstanz zu beeinträchtigen. Gegenüber der klassischen Radiografie, bei der nur eine zweidimensionale Abbildung erreicht wird, bietet die CT-Untersuchung die Möglichkeit innenliegende Strukturen dreidimensional zu erfassen. Die notwendige Bestimmung der Objektoberfläche erlaubt zudem die Erstellung eines Oberflächenmodells des untersuchten Gegenstandes. Damit lassen sich unter anderem mechanische Simulationen (Belastung, Durchbiegung, Durchströmung) durchführen. Der erzeugte Datensatz kann somit auch zur Herstellung eines Replikats im 3D-Druckverfahren genutzt werden. Anhand der Untersuchung der Mandoline von Smorsone wird gezeigt, wie eine CT-Messung durchgeführt wird und wie in dem anschließend rekonstruierten 3D-Datensatz mittels Koordinatenmesstechnik Maße (Abstände, Wandstärken, Winkel) exakt ermittelt werden können. T2 - Jahrestagung der Gesellschaft für Musikforschung CY - Berlin, Germany DA - 28.09.2022 KW - Mikro-CT KW - Bildverarbeitung KW - Holz KW - Bronze KW - ZfP PY - 2022 AN - OPUS4-56412 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Werner, Tiago T1 - Experimentelle und numerische Untersuchung des Druckanschwingens von bruchmechanischen Proben aus konventionell und additiv gefertigtem 316L Stahl N2 - Die Erzeugung rissschließfreier Anrisse in gekerbten bruchmechanischen Proben für anschließende Ermüdungsversuche kann durch eine zyklische Druckbelastung an der Kerbe erfolgen: Bei der Erstbelastung wird eine plastische Verformung an der Kerbspitze erzeugt, welche Zugeigenspannungen und damit eine risstreibende Kraft bei der folgenden zyklischen Druckbelastung hervorruft. Durch das Risswachstum kommt es zu einer Entspannung, bis der Riss schließlich arretiert, weil die effektive risstreibende Kraft auf den Schwellenwert abgesunken ist. Um Kurzrisswachstum in additiv, mittels pulverbettbasiertem Laserstrahlschmelzen (Laser Powder Bed Fusion - LPBF) gefertigtem AISI 316L Stahl und seinem konventionell erzeugten, warmgewalzten Pendant zu untersuchen, wurde dieses Verfahren im Rahmen der vorliegenden Arbeit genutzt. Im Falle des additiv gefertigten Materials kam es zu unerwartet langem Ermüdungsrisswachstum, bevor der Riss arretierte. Zur Ermittlung der Ursache erfolgte eine Messung der Eigenspannungsverteilungen mittels Neutronendiffraktion in der Kerbebene der additiv gefertigten Proben. Anschließend wurde ein Finite-Elemente-Modell zur Simulation des Ermüdungsrisswachstums in konventionellem und additiv gefertigtem Material implementiert. Im Rahmen dieses Vortrages wird insbesondere auf das Vorgehen bei der Simulation und auf die getroffenen Annahmen und Vereinfachungen eingegangen. Die Resultate werden mit den experimentellen Ergebnissen verglichen und das für die Simulation von Risswachstum genutzte Knoten-Freigabe-Verfahren (Node-Release), das Einbringen von Eigenspannungen als initiale Spannungen in der Simulation, und die Rechengrößen zur Quantifizierung der risstreibenden Kraft kritisch diskutiert. T2 - 56. DVM Tagung "Bruchmechanik und Bauteilsicherheit" CY - Kassel, Germany DA - 20.02.2024 KW - PBF/LB KW - Additive Fertigung KW - Ermüdungsrisswachstum KW - Druckanschwingen KW - FEM KW - Node-release KW - Eigenspannungsmessung KW - Neutronendiffraktion PY - 2024 AN - OPUS4-59559 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Evans, Alexander A1 - Przyklenk, A. T1 - European Metrology Network for Advanced Manufacturing N2 - The progress of Advanced Manufacturing, which has been identified by the European Commission as a Key Enabling Technology (KET) for future economic and societal progress is strongly reliant on the development of metrology capabilities. EURAMET, the association of metrology institutes in Europe, has established metrology research programs to address the metrology requirements across a spectrum of different thematic areas. In order to leverage the benefits of these developments on the wider industrial landscape, a high-level coordination of the metrology community supporting the Advanced Manufacturing landscape is required. This coordination is aimed to be achieved by the establishment of European Metrology Networks (EMNs), which are intended by EURAMET to provide a sustainable structure for stakeholder engagement and support. The joint networking project 19NET01 AdvManuNet funded by EMPIR for 4 years, started in June 2020 and aims to accelerate the process of establishing an EMN to strengthen Europe’s position in Advanced Manufacturing. The AdvManuNet project aims to support the establishment of an EMN on Advanced Manufacturing via the following specific aims: 1. Creation of a single hub for stakeholder engagement across the landscape of various industrial sectors including relevant societies and standardization bodies. 2. Development of a Strategic Research Agenda (SRA) and roadmaps for Advanced Manufacturing metrology based on the stakeholder engagement activities, considering current gaps in metrological capabilities existing networks and roadmaps. 3. Establish a knowledge-sharing program for Advanced Manufacturing stakeholders, promoting the dissemination and exploitation of the results of the project, including those from previous EU funded research projects. 4. Development of a sustainable web-based platform and service desk for Advanced Manufacturing stakeholders to allow for easy access to European metrology capabilities and support the wider advanced manufacturing community with metrology-based requirements. 5. Develop a plan for a coordinated and sustainable European metrology infrastructure for Advanced Manufacturing via a European Metrology Network. The project concept followed by the scope and definition of Advanced Manufacturing will be described. The analysis of the current capability of metrology for Advanced Manufacturing and the preliminary concepts for the strategic research agenda will be presented with a focus on dimensional metrology. T2 - CIM 2021 CY - Online meeting DA - 07.09.2021 KW - Advanced manufacturing KW - Metrology KW - European Metrology Networks (EMNs) KW - Strategic Research Agenda (SRA) KW - Stakeholder PY - 2021 AN - OPUS4-54101 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ulbricht, Alexander T1 - Do Microbes like Additively Manufactured Aluminium? First Details of a Corrosion Test using Sulphate-Reducing Bacteria N2 - Additively manufactured metals become relevant for industrial application. Although many studies on wet corrosion of these metals have been conducted, to the authors knowledge no study seems to contain microbiological corrosion (MIC). In the presented study an experiment was conducted on PBF-LB/AlSi10Mg to test this material's susceptibility for MIC. The tested specimen were analysed using Computed Tomography before and after the MIC experiment to enable a detailed characterisation the damage on the specimens' global and local level. A global reduction of material was observed. In addition, localised damage along process inherent features of the materials microstructure was observed. T2 - Beiratssitzung TF Umwelt CY - Berlin, Germany DA - 17.03.2025 KW - Computed Tomography KW - Additive Manufacturing KW - Biocorrosion KW - Sulphate-reducing Bacteria KW - Microbially influenced corrosion PY - 2025 AN - OPUS4-62772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - O'Connor, Daniel T1 - European Metrology Network (EMN) for Advanced Manufacturing Development of the Strategic Research Agenda (SRA) N2 - The European Commission has identified Advanced Manufacturing and Advanced Materials as two of six Key Enabling Technologies (KETs). It is considered that Metrology is a key enabler for the advancement of these KETs. Consequently, EURAMET, the association of metrology institutes in Europe, has strengthened the role of Metrology for these KETs by enabling the creation of a European Metrology Network (EMN) for Advanced Manufacturing. The EMN is comprised of National Metrology Institutes (NMIs) and Designated Institutes (DIs) from across Europe and was formally established in October 2021. The aim of the EMN is to provide a high-level coordination of European metrology activities for the Advanced Manufacturing community. The EMN itself is organized in three sections representing the major stages of the manufacturing chain: 1) Advanced Materials, 2) Smart Manufacturing Systems, and 3) Manufactured Components & Products. The EMN for Advanced Manufacturing is engaging with stakeholders in the field of Advanced Manufacturing (large companies & SMEs, industry organisations, existing networks, and academia), as well as the wider Metrology community, including Technical Committees, to provide input for the Strategic Research Agenda (SRA) on Metrology for Advanced Manufacturing. This contribution will give an overview about the first version of the SRA prepared by the EMN for Advanced Manufacturing. T2 - Euspen, 23rd International Conference & Exhibitio CY - Copenhagen, Danmark DA - 13.06.2023 KW - European Metrology Network (EMN) KW - Advanced Manufacturing KW - Metrology KW - Strategic Research Agenda (SRA) PY - 2023 AN - OPUS4-59176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Oster, Simon T1 - From Thermographic In-situ Monitoring to Porosity Detection – A Deep Learning Framework for Quality Control in Laser Powder Bed Fusion N2 - In this study, we present an enhanced deep learning framework for the prediction of porosity based on thermographic in-situ monitoring data of laser powder bed fusion processes. The manufacturing of two cuboid specimens from Haynes 282 (Ni-based alloy) powder was monitored by a short-wave infrared camera. We use thermogram feature data and x-ray computed tomography data to train a convolutional neural network classifier. The classifier is used to perform a multi-class prediction of the spatially resolved porosity level in small sub-volumes of the specimen bulk. T2 - Sensor and Measurement Science International CY - Nurnberg, Germany DA - 08.05.2023 KW - Laser powder bed fusion KW - In-situ monitoring KW - Thermography KW - Machine Learning KW - Porosity PY - 2023 AN - OPUS4-57614 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishurova, Tatiana A1 - Serrano-Munoz, Itziar T1 - Multiscale residual stress analysis and synchrotron X-ray refraction of additively manufactured parts N2 - The overview of the activity of group 8.5 Micro-NDT (BAM, Belin, Germany) in the field of additively manufacturing material characterization will be presented. The challenges in the residual stress analysis of AM components are discussed on the basis on the show studies performed in BAM. Also, the synchrotron X-ray refraction technique, available in BAM, is presented, showing example of in-situ heating test of Al10SiMg AM material. T2 - Seminar at Grenoble INP, Science et Ingénierie des Matériaux et Procédés (SIMaP) CY - Grenoble, France DA - 01.07.2022 KW - Additive manufacturing KW - Residual stress KW - X-ray refraction KW - Computed tomography PY - 2022 AN - OPUS4-55232 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Serrano-Munoz, Itziar T1 - Influence of microstructure and residual stress state on the fatigue behaviour of a PBF-LB/M AlSi10Mg alloy N2 - The high cooling rates (~106 K/s) occurring during Laser Powder Bed Fusion (PBF-LB/M) of AlSi10Mg induce to the formation of a fine nanometric silicon network in the as-built condition. Such unprecedented microstructure enhances the mechanical strength when compared to equivalent as-cast materials. Nevertheless, PBF-LB/M also leads to high magnitude residual stress (RS) due to the extreme localized temperature gradients. The presence of RS can be detrimental to the fatigue life of engineering components, and great efforts are focused on understanding their generation and evolution after post-process heat treatments. Typically, T6 heat treatments are used to mitigate RS and improve mechanical performances by Mg2Si precipitation during ageing at 160-180°C. Nevertheless, the solutionizing at 500-540°C vanishes the fine silicon network, leading to the formation of micrometric (average of ~2-5 µm) polygonal Si particles, similar to those observed in T6 heat-treated Al-Si cast materials. Therefore, the aim of this work is to evaluate the ability of two so-called low temperature heat treatments (i.e., at 265°C and 300°C) to mitigate RS while retaining the fine as-built microstructure inherent to PBF-LB/M AlSi10Mg. The fatigue behavior of the as-built material is subsequently compared to the two low temperature conditions. T2 - LightMat 2023 CY - Trondheim, Norway DA - 21.06.2023 KW - AlSi10Mg KW - Fatigue crack propagation KW - Residual stress KW - Post processing heat treatment PY - 2023 AN - OPUS4-57807 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -