TY - CONF A1 - Schumacher, David T1 - From W. C. Röntgen to modern Tomography N2 - A not complete review of X-Ray related milestones from 1895 to the 21st century. T2 - ITN GW4SHM, First Training Event CY - Online Meeting DA - 23.11.2020 KW - X-Ray KW - Computed Tomography KW - Laminography KW - Digital Detector Arrays KW - Wilhelm Conrad Röntgen PY - 2020 AN - OPUS4-51881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Ahmadi, Samim A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Burgholzer, P. A1 - Jung, P. A1 - Caire, G. T1 - Laser excited super resolution thermal imaging for nondestructive inspection of internal defects N2 - A photothermal super resolution technique is proposed for an improved inspection of internal defects. To evaluate the potential of the laser-based thermographic technique, an additively manufactured stainless steel specimen with closely spaced internal cavities is used. Four different experimental configurations in transmission, reflection, stepwise and continuous scanning are investigated. The applied image post-processing method is based on compressed sensing and makes use of the block sparsity from multiple measurement events. This concerted approach of experimental measurement strategy and numerical optimization enables the resolution of internal defects and outperforms conventional thermographic inspection techniques. KW - Super resolution KW - Photothermal KW - Imaging KW - Compressed sensing KW - Internal defects KW - Nondestructive testing PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-518866 DO - https://doi.org/10.48550/arXiv.2007.03341 SN - 2331-8422 SP - 1 EP - 9 PB - Cornell University CY - Ithaca, NY AN - OPUS4-51886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias T1 - Non-Destructive Testing - Electromagnetic Methods N2 - This presentation contains a short summary about the basics of eddy current testing and magnetic flux leakage testing. In addition, the main focus of the talk lies on the application of point-like sensors like GMR for NDT. T2 - 1st Training Event - ITN project GW4SHM CY - Online meeting DA - 23.11.2020 KW - GMR KW - Magnetic flux leakage testing KW - Eddy current testing PY - 2020 AN - OPUS4-51889 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias T1 - Wirbelstromprüfung von Komposit-Druckbehältern N2 - Komposit-Druckgefäße für den Gefahrguttransport sowie für Wasserstoff-und Erdgasfahrzeuge bestehen aus einem lasttragenden Komposit und einer gasdichten, metallischen oder polymeren Barriereschicht (Liner). Zur Untersuchung der Integrität der Druckflaschen wurde die Wirbelstromprüfung eingesetzt. Hierbei wurden verschiedene Frequenzbereiche angewendet, um so die unterschiedlichen Materialien untersuchen zu können. Ziel der Untersuchungen war es, alterungsbedingte Schädigungen rechtzeitig zu detektieren. Der Vortrag stellt diese Ergebnisse vor. T2 - Carbon United - Gemeinsame Sitzung 3er-AG Zerstörungsfreie Werkstoff- u. Bauteilprüfung, Verbindungstechnik, Engineering CY - Online meeting DA - 07.12.2020 KW - Wirbelstromprüfung KW - CFK KW - Druckbehälter PY - 2020 AN - OPUS4-51892 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Léonard, Fabien T1 - Overview of XCT data processing workflow for ammonium nitrate prills quantitative analysis N2 - This video presents the data processing workflow that was developed to perform the quantitative structural and morphological analysis of ammonium nitrate prills by x-ray computed tomography. KW - ANFO KW - Data processing KW - Explosives KW - Porosity KW - Surface area KW - XCT PY - 2020 DO - https://doi.org/10.5281/zenodo.3611339 PB - Zenodo CY - Geneva AN - OPUS4-51897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bühling, Benjamin T1 - Entwicklung eines luftgekoppelten Ultraschall-Echo-Prüfverfahrens mittels fluidischer Anregung N2 - In vielen technischen Bereichen werden Ultraschallverfahren zur zerstörungsfreien Werkstoffprüfung (ZfP) eingesetzt um auf Basis der Signalstärke und der Laufzeit Einbauteile und Beschädigungen zu orten. Luftgekoppelter Ultraschall spielt bisher in kommerziellen Anwendungen vor Allem im Bauwesen eine untergeordnete Rolle, da die Differenz der akustischen Impedanzen von Luft und Festkörpern immense Verluste beim Übergang des Schallsignals hervorruft. Im Rahmen des Promotionsvorhabens soll die Eignung eines neuartigen Anregungsprinzip untersucht werden, mit dem ein Großteil dieser Verluste vermieden werden soll. Anstelle eines Festkörpers soll mit Hilfe einer fluidischen Düse Druckluft zur Signalerzeugung eingesetzt werden. Die Impedanzverluste zwischen Aktuatormembran und Umgebungsluft entfallen daher. Die gezielte Schallerzeugung durch einen pulsierenden Freistrahl ist weitgehend unerforscht. Es ist daher notwendig, den so erzeugten Schallpuls in der Interaktion mit dem transienten Strömungsfeld zu untersuchen. Das kompressible Medium Luft und die geringen räumlichen Dimensionen einer hochfrequenten Pulsdüse werfen darüber hinaus einige Herausforderungen hinsichtlich der eingesetzten Messtechnik auf. Hier sollen geeignete Verfahren weiterentwickelt und validiert werden, um die Eignung des fluidisch erzeugten Pulses zu überprüfen. In diesem Vortrag werden erste Messungen an einem fluidischen Schalter mit denen an einem kommerziellen Luftultraschallprüfkopf verglichen. T2 - Doktorandenseminar BAM Abt. 8 CY - Berlin, Germany DA - 17.02.2020 KW - ZfP KW - Ultraschall KW - NDT KW - Ultrasound KW - Air-coupled KW - Non-Contact KW - Luftgekoppelt KW - Kontaktlos PY - 2020 AN - OPUS4-51120 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reichel, V. E. A1 - Matuszak, J. A1 - Bente, Klaas A1 - Heil, T. A1 - Kraupner, A. A1 - Dutz, S. A1 - Cicha, I. A1 - Faivre, D. T1 - Magnetite-Arginine Nanoparticles as a Multifunctional Biomedical Tool N2 - Iron oxide nanoparticles are a promising platform for biomedical applications, both in terms of diagnostics and therapeutics. In addition, arginine-rich polypeptides are known to penetrate across cell membranes. Here, we thus introduce a system based on magnetite nanoparticles and the polypeptide poly-l-arginine (polyR-Fe3O4). We show that the hybrid nanoparticles exhibit a low cytotoxicity that is comparable to Resovist®, a commercially available drug. PolyR-Fe3O4 particles perform very well in diagnostic applications, such as magnetic particle imaging (1.7 and 1.35 higher signal respectively for the 3rd and 11th harmonic when compared to Resovist®), or as contrast agents for magnetic resonance imaging (R2/R1 ratio of 17 as compared to 11 at 0.94 T for Resovist®). Moreover, these novel particles can also be used for therapeutic purposes such as hyperthermia, achieving a specific heating power ratio of 208 W/g as compared to 83 W/g for Feridex®, another commercially available product. Therefore, we envision such materials to play a role in the future theranostic applications, where the arginine ability to deliver cargo into the cell can be coupled to the magnetite imaging properties and cancer fighting activity. KW - Iron oxide KW - Nanoparticle KW - Theranostics KW - MRI KW - Hyperthermia PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-515993 DO - https://doi.org/10.3390/nano10102014 VL - 10 IS - 10 SP - 2014 PB - MDPI AN - OPUS4-51599 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lu, Xin A1 - Krebber, Katerina T1 - Direct detection based φOTDR using the Kramers-Kronig receiver N2 - A Kramers-Kronig (KK) receiver is applied to a phase-sensitive optical time domain reflectometry based on direct detection. An imbalanced Mach-Zehnder interferometer with a 2× 2 coupler is used in sensing system to encode the phase information into optical intensity. The directly obtained signal is treated as the in-phase component, and the KK receiver provides the quadrature component by Hilbert transform of the obtained signal, so that the optical phase can be retrieved by IQ demodulation. The working principle is well explained, and the obtained phase variance is theoretically analyzed. The experiment demonstrates the functionality of the sensor and validates the theoretical analysis. KW - Kramers-Kronig detector KW - Distributed fiber sensing KW - Acoustic sensing PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-516803 UR - https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-28-24-37058&id=442839 DO - https://doi.org/10.1364/OE.405723 VL - 28 IS - 24 SP - 37058 EP - 37068 PB - Optical Society of America AN - OPUS4-51680 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, C. A1 - Bohling, C. A1 - Millar, S. A1 - Günther, Tobias A1 - Wilsch, Gerd ED - Krieger, J. ED - Isecke, B. T1 - Schnelle ortsaufgelöste Chloridbestimmung mit der laserinduzierten Plasmaspektroskopie (LIBS) N2 - Im Zuge der Ist-Zustandserfassung von Stahl- und Spannbetonbauwerken spielt die chemische Analyse von Beton eine zentrale Rolle. Durch den externen Eintrag von schädigenden Substanzen wie Chlorid oder Alkalien aus Tausalzen oder Meerwasser, kann u.U. der Beton und/oder die Stahlbewehrung angegriffen werden. Bei Überschreitung kritischer korrosionsauslösender Chloridgehalte, z.B. bei Stahlbeton 0,4 M.-% (bzw. 0,5 M.-%) und Spannbeton 0,2 M.-% bezogen auf den Zement, erhöht sich das Risiko für eine Chlorid-induzierte Korrosion. Für die Beurteilung eines Instandsetzungsbedarfs und, sofern notwendig, der Erarbeitung eines Instandsetzungskonzeptes muss nach der Rili-SIB1 ein sachkundiger Planer herangezogen werden. Standardmäßig werden für die chemische Analyse Bohrkerne bzw. Bohrmehlproben aus dem zu untersuchenden Bauwerk entnommen und nach aufwendiger Probenvorbereitung nasschemisch analysiert (nach DAfStb Heft 401 oder DIN 14629). Dabei wird der Gesamtchloridgehalt bezogen auf die Einwaage angegeben. Eine Umrechnung auf den Zementgehalt erfolgt i.d.R. durch Schätzwerte. Der Einsatz der laserinduzierten Plasmaspektroskopie (LIBS) wird seit Mitte der 90er Jahren an der Bundesanstalt für Materialforschung und -prüfung erforscht, um den Chloridgehalt durch eine ortsaufgelöste Elementanalyse an einer Betonprobe möglichst genau zu ermitteln. Die zweidimensionale LIBS-Messung mit einer lateralen Auflösung von 100 µm x 100 µm erlaubt die Berücksichtigung der Heterogenität von Beton. Dabei lassen sich die Bindemittelmatrix und die Gesteinskörnung separat betrachten, wodurch sich die Aussagekraft der Ergebnisse und somit die Sicherheit der chemischen Zustandserfassung erhöht. Durch die stetige Weiterentwicklung von Komponenten wie Laser, Spektrometer und analytischer Auswerteroutinen sind mittlerweile automatisierte Systeme für die schnelle LIBS-Analyse auf dem Markt verfügbar. In diesem Vortrag wird der aktuelle Stand der Technik anhand von Praxisbeispielen präsentiert und entscheidende Vorteile gegenüber dem Standardverfahren herausgestellt. Aufgrund der Möglichkeit für eine simultane Multielementanalyse mit LIBS werden weitere Anwendungen, wie z.B. die Ermittlung der Karbonatisierungstiefe, Untersuchungen von Transportprozessen, Chlorideintrag entlang von Rissen oder Untersuchungen von Elementverteilungen im Kontext einer AKR vorgestellt. T2 - 4. Brückenkolloquium CY - Online meeting DA - 08.09.2020 KW - Chloride KW - Beton KW - LIBS KW - Schädigung PY - 2020 SN - 978-3-8169-3518-6 SP - 465 EP - 471 PB - Narr Francke Attempto Verlag GmbH + Co. KG CY - Tübingen AN - OPUS4-51681 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, C. T1 - Schnelle ortsaufgelöste Chloridbestimmung mit der laserinduzierten Plasmaspektroskopie N2 - Im Zuge der Ist-Zustandserfassung von Stahl- und Spannbetonbauwerken spielt die chemische Analyse von Beton eine zentrale Rolle. Durch den externen Eintrag von schädigenden Substanzen wie Chlorid oder Alkalien aus Tausalzen oder Meerwasser, kann u.U. der Beton und/oder die Stahlbewehrung angegriffen werden. Bei Überschreitung kritischer korrosionsauslösender Chloridgehalte, z.B. bei Stahlbeton 0,4 M.-% (bzw. 0,5 M.-%) und Spannbeton 0,2 M.-% bezogen auf den Zement, erhöht sich das Risiko für eine Chlorid-induzierte Korrosion. Für die Beurteilung eines Instandsetzungsbedarfs und, sofern notwendig, der Erarbeitung eines Instandsetzungskonzeptes muss nach der Rili-SIB1 ein sachkundiger Planer herangezogen werden. Standardmäßig werden für die chemische Analyse Bohrkerne bzw. Bohrmehlproben aus dem zu untersuchenden Bauwerk entnommen und nach aufwendiger Probenvorbereitung nasschemisch analysiert (nach DAfStb Heft 401 oder DIN 14629). Dabei wird der Gesamtchloridgehalt bezogen auf die Einwaage angegeben. Eine Umrechnung auf den Zementgehalt erfolgt i.d.R. durch Schätzwerte. Der Einsatz der laserinduzierten Plasmaspektroskopie (LIBS) wird seit Mitte der 90er Jahren an der Bundesanstalt für Materialforschung und -prüfung erforscht, um den Chloridgehalt durch eine ortsaufgelöste Elementanalyse an einer Betonprobe möglichst genau zu ermitteln. Die zweidimensionale LIBS-Messung mit einer lateralen Auflösung von 100 µm x 100 µm erlaubt die Berücksichtigung der Heterogenität von Beton. Dabei lassen sich die Bindemittelmatrix und die Gesteinskörnung separat betrachten, wodurch sich die Aussagekraft der Ergebnisse und somit die Sicherheit der chemischen Zustandserfassung erhöht. Durch die stetige Weiterentwicklung von Komponenten wie Laser, Spektrometer und analytischer Auswerteroutinen sind mittlerweile automatisierte Systeme für die schnelle LIBS-Analyse auf dem Markt verfügbar. In diesem Vortrag wird der aktuelle Stand der Technik anhand von Praxisbeispielen präsentiert und entscheidende Vorteile gegenüber dem Standardverfahren herausgestellt. Aufgrund der Möglichkeit für eine simultane Multielementanalyse mit LIBS werden weitere Anwendungen, wie z.B. die Ermittlung der Karbonatisierungstiefe, Untersuchungen von Transportprozessen, Chlorideintrag entlang von Rissen oder Untersuchungen von Elementverteilungen im Kontext einer AKR vorgestellt. T2 - 4. Brückenkolloquium CY - Online meeting DA - 08.09.2020 KW - Beton KW - LIBS KW - Schädigung KW - Chloride PY - 2020 AN - OPUS4-51683 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Karapanagiotis, Christos T1 - Machine learning for strain and temperature discrimination in Brillouin distributed sensing N2 - Short presentation of the PhD project in machine learning based Brillouin distributed sensing. Machine learning can be used to enhance the performance of BOFDA and reduce considerably the measurement time. Apart from this, ML can also be used to extract more information from the Brillouin gain spectrum in order to render the temperature and strain discrimination possible T2 - PhD Day 2020 CY - Online meeting DA - 15.09.2020 KW - Fiber optics sensors KW - Machine learning PY - 2020 AN - OPUS4-51689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -