TY - JOUR A1 - Ferrier, Emmanuel A1 - Michel, Laurent A1 - Thiele, Marc A1 - Mercier, Julien T1 - Strain-rate effect on the bond strength of external bonded reinforced carbon fiber-reinforced polymer for concrete structure N2 - The aim of the presented study is to investigate the dynamic loading strength of an external bonded fiber-reinforced polymers (FRP) system under seismic loading. 16 bonded FRP samples under different loading speeds ranging as 0.0000167–0.8 m /s were examined to determine the characteristics of the FRP bond strength on the concrete. The mechanical tests involved measuring the concrete/FRP shear properties using a double-lap shear test. Sixteen concrete specimens were cast, strengthened and surface preparation, instrumented, and driven to failure in the LMC laboratory and the BAM laboratory (Germany). Dynamic loading increased the bonded strength mainly because of an increase in the concrete tensile strength. Experimental data are then analysed and competed with the equation given by the new European standard that develop the design of external bonded FRP. The characteristic properties and bonded strength obtained by design equation were compared. Based on the results design equation are modified. KW - EBR strengthening system KW - Desing bond strength KW - Durability PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625354 DO - https://doi.org/10.1016/j.conbuildmat.2025.140216 SN - 1879-0526 VL - 466 SP - 1 EP - 14 PB - Elsevier Ltd. AN - OPUS4-62535 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Glienke, R. A1 - Kalkowsky, F. A1 - Hobbacher, A. F. A1 - Holch, A. A1 - Thiele, Marc A1 - Marten, F. A1 - Kersten, R. A1 - Henkel, K.-M. T1 - Evaluation of the fatigue resistance of butt‑welded joints in towers of wind turbines - A comparison of experimental studies with small scale and component tests as well as numerical based approaches with local concepts N2 - Wind turbines are exposed to a high number of load cycles during their service lifetime. Therefore, the fatigue strength verification plays an important role in their design. In general, the nominal stress method is used for the fatigue verification of the most common used butt-welded joints. The Eurocode 3 part 1–9 is the current design standard for this field of application. This paper presents recent results of fatigue tests on small-scaled specimens and large components with transverse butt welds to discuss the validity of the FAT-class. Furthermore, results from numerical simulations for the verification with the effective notch stress and the crack propagation approach are used for comparison. Based on the consistency between the numerical results and the fatigue tests, the influence of the seam geometry on the fatigue resistance was investigated. Finally, a prediction of the fatigue strength of butt-welded joints with plate thicknesses up to 80 mm was carried out. KW - Transverse butt weld KW - Weld imperfections KW - Wind turbine tower KW - Fatigue strength KW - Local approaches KW - Large components KW - Wind energy PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-596648 DO - https://doi.org/10.1007/s40194-023-01630-3 SN - 1878-6669 SP - 1 EP - 26 PB - Springer CY - Berlin AN - OPUS4-59664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thibaux, Philippe A1 - Thiele, Marc A1 - Van Wittenberghe, Jeroen A1 - Baeßler, Matthias T1 - Comparison of resonance and hydraulic testing on large scale fatigue tests of welded tubular joints for offshore wind turbine foundations N2 - Jackets structures as foundations for offshore wind energy converters are efficient solutions. But these structures require the welding of a large number of joints. The design of the Jacket structures is typically driven by fatigue. Therefore, consequently the fatigue strength of the joints is a primary parameter for an optimized design. The present paper investigates if tubular joints produced by manual welding using the current techniques have an improved performance compared to the relevant standards that are applied for the design of the foundations. To investigate this, 4 full-scale tests in geometry representative of a structure were performed, 2 using a resonance method and 2 using a three-point bending method with hydraulic actuators. The results are similar, with cracks initiated early and extending extensively before failure. The results are very close to the current T-curve from DNV RP-C203 applied for tubular joints. KW - Fatigue KW - Tubular joints KW - Resonance testing KW - Steel welds PY - 2025 DO - https://doi.org/10.1016/j.ijfatigue.2024.108797 SN - 0142-1123 VL - 193 SP - 1 EP - 16 PB - Elsevier Ltd. AN - OPUS4-62373 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thiele, Marc A1 - Pirskawetz, Stephan T1 - Analysis of damage evolution in concrete under fatigue loading by acoustic emission and ultrasonic testing N2 - The fatigue process of concrete under compressive cyclic loading is still not completely explored. The corresponding damage processes within the material structure are especially not entirely investigated. The application of acoustic measurement methods enables a better insight into the processes of the fatigue in concrete. Normal strength concrete was investigated under compressive cyclic loading with regard to the fatigue process by using acoustic methods in combination with other nondestructive measurement methods. Acoustic emission and ultrasonic signal measurements were applied together with measurements of strains, elastic modulus, and static strength. It was possible to determine the anisotropic character of the fatigue damage caused by uniaxial loading based on the ultrasonic measurements. Furthermore, it was observed that the fatigue damage seems to consist not exclusively of load parallel oriented crack structures. Rather, crack structures perpendicular to the load as well as local compacting are likely components of the fatigue damage. Additionally, the ultrasonic velocity appears to be a good indicator for fatigue damage beside the elastic modulus. It can be concluded that acoustic methods allow an observation of the fatigue process in concrete and a better understanding, especially in combination with further measurement methods. KW - Concrete KW - Fatigue KW - Damage evolution KW - Ultrasonic testing KW - Acoustic emission PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-541891 DO - https://doi.org/10.3390/ma15010341 SN - 1996-1944 VL - 15 IS - 1 SP - 341 EP - 355 PB - MDPI CY - Basel AN - OPUS4-54189 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thibaux, Philippe A1 - Van Wittenberghe, Jeroen A1 - Fricke, Wolfgang A1 - Thiele, Marc A1 - Nielsen, Lars Peter A1 - Conti, Fabien T1 - Results of the JaCo project: fatigue strength of robot‑welded tubular joints for offshore wind energy converters N2 - Jacket foundations requires the welding of a large number of tubular joints. These foundations type is suitable to support wind energy converters in deeper water. In order to increase the production speed and its quality, robot systems were developed to produce tubular joints. Since fatigue is dominating the design of these structures, an assessment of the performance of tubular joints produced by robots was performed and compared with the performance of manually welded joints. 18 large-scale tests were performed on joints with dimensions representative for offshore structures, which were produced in industrial environment. Breakthrough cracks occurred through the chord, with cracks initiated at the weld toe, although in some cases cracks were also initiated between weld beads. The measured fatigue strengths of joints produced by robot were similar or higher than the T-curve of DNV-RP-C203. Some delivered components showed fatigue strength that was more than 20% higher than the standard curve. These results emphasize that mastering the welding process with robots is necessary to achieve superior levels of fatigue strength. KW - Fatigue KW - Tubular joint KW - Robot welding KW - Hot spot method KW - Large-scale testing PY - 2024 DO - https://doi.org/10.1007/s40194-024-01903-5 SN - 1878-6669 SP - 1 EP - 14 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-62319 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiehle, Philipp A1 - Baier, Johanna A1 - Thiele, Marc T1 - Structural Design of Earth Masonry in Accordance with Eurocode 6 – Considering Moisture Content and E/fk Ratio N2 - The load‐bearing behaviour of earth masonry is similar to conventional masonry, with two key differences: compressive strength and Young's modulus are dependent on moisture content, and the ratio between Young's modulus and characteristic compressive strength (E/fk) is significantly lower. The current design concept according to the Lehmbau Regeln does not explicitly address these factors, relying instead on a general safety margin, leading to an underestimation of the load‐bearing capacity of modern earth masonry.Compression tests on small‐scale masonry specimens and storey‐high walls revealed that compressive strength and Young's modulus decrease inversely proportional to the increase in relative humidity. Additionally, it was found that conventional masonry design guidelines overestimate the buckling resistance of earth masonry due to its low E/fk ratio of ∼440. However, this ratio remains independent of moisture content, simplifying structural design, as the load‐bearing capacity is only influenced by wall slenderness.The study's findings form the foundation for the newly published German design standard DIN 18940, which explicitly considers moisture content through service classes with moisture factors and addresses the low E/fk ratio with a bilinear adaptation of the reduction factor considering the slenderness. Along with the introduction of the semi‐probabilistic design concept and rigid‐plastic determination of cross‐sectional load‐bearing capacity, modern earth masonry can now be applied in buildings up to four storeys. T2 - Earth Builder Summit CY - Biberach, Germany DA - 06.03.2025 KW - Service class KW - Earth masonry KW - Structural design KW - Moisture PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-637803 DO - https://doi.org/10.1002/cepa.3287 SN - 2509-7075 VL - 8 IS - 1 SP - 9 EP - 21 PB - Ernst & Sohn GmbH AN - OPUS4-63780 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -