TY - CONF A1 - Chemello, Giovanni T1 - Towards Reproducible Analysis Workflows for Reliable Structural and Chemical Composition of Industrial Graphene N2 - The scientific and technological interest in graphene has been growing more and more in the late years due to its outstanding properties and diverse promising applications. However, graphene implementation into the industrial market is still limited and many challenges are yet to be addressed before this material can become suitable for the large-scale production. One of the most crucial challenge to overcome is to develop reliable and reproducible ways to characterize the material properties which can heavily affect the product performance. In our study the chemical composition of nine different samples of industrial graphene, graphene oxide and functionalized graphene were investigated. The samples were analysed both in form of powder and pellets. A comparative characterisation of the chemical composition was performed through X-ray Photoelectron Spectroscopy (XPS) and Energy Dispersive X-ray Spectroscopy (EDX). XPS depth resolution is in the order of 10 nm, while for EDX the analysis was performed at two different energy levels, i.e. 5 keV and 15 keV, and thus varying the analysis depth from 200 nm to 2000 nm. The XPS measurement area is 300x700 µm² while the EDX measurement was performed by analysing a grid of 25 locations (5x5) of 150 x 150 ?m2 area, covering the whole pellet surface of 5 mm diameter and then calculating the mean of the elemental concentration. The results of the elemental concentration values from XPS and EDX analyses show a good agreement for all the elements presents in the samples, despite the different spatial resolutions of the two techniques. Therefore, the samples appear homogeneous both in the lateral and vertical directions. The results relative to powder and pellets samples do not differ in a significant way except for a slight increase in the carbon content regarding the pellet samples, probably due to a minor contamination effect introduced through pressing. Nevertheless, pellets samples appear to be quite representative for the material while being much more convenient in terms of handling and safety compared to nano-powders and providing a regular flat surface for EDX analysis. Finally, this approach correlating XPS and EDS represents a simple, fast and reliable way for characterizing the chemical composition and the homogeneity of industrial graphene. This study is part of the project Standardisation of structural and chemical properties of graphene (ISO-G-SCoPe) which has received funding from the EMPIR programme co-financed by the Participating States and from the European Union?s Horizon 2020 research and innovation programme under Grant agreement No. 19NRM04. T2 - SALSA Make and Measure... and Machines CY - Online meeting DA - 16.09.2021 KW - Graphene KW - XPS KW - EDX KW - Graphene functionalisation PY - 2021 UR - https://fakultaeten.hu-berlin.de/en/mnf/forschung_internationales/grs/salsa/SALSA_MM AN - OPUS4-53463 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Chemello, Giovanni T1 - Correlative analysis through XPS and EDX measurements for accurate chemical composition of industrial Graphene N2 - The scientific and technological interest in graphene has been growing more and more in the late years due to its outstanding properties and diverse promising applications. However, graphene implementation into the industrial market is still limited and many challenges are yet to be addressed before this material can become suitable for the large-scale production. One of the most crucial challenge to overcome is to develop reliable and reproducible ways to characterize the material properties which can heavily affect the product performance. In our study the chemical composition of nine different samples of industrial graphene, graphene oxide and functionalized graphene were investigated. The samples were analysed both in form of powder and pellets. A comparative characterisation of the chemical composition was performed through X-ray Photoelectron Spectroscopy (XPS) and Energy Dispersive X-ray Spectroscopy (EDX). XPS depth resolution is in the order of 10 nm, while for EDX the analysis was performed at two different energy levels, i.e. 5 keV and 15 keV, and thus varying the analysis depth from 200 nm to 2000 nm. The XPS measurement area is 300x700 µm² while the EDX measurement was performed by analysing a grid of 25 locations (5x5) of 150 x 150 ?m2 area, covering the whole pellet surface of 5 mm diameter and then calculating the mean of the elemental concentration. The results of the elemental concentration values from XPS and EDX analyses show a good agreement for all the elements presents in the samples, despite the different spatial resolutions of the two techniques. Therefore, the samples appear homogeneous both in the lateral and vertical directions. The results relative to powder and pellets samples do not differ in a significant way except for a slight increase in the carbon content regarding the pellet samples, probably due to a minor contamination effect introduced through pressing. Nevertheless, pellets samples appear to be quite representative for the material while being much more convenient in terms of handling and safety compared to nano-powders and providing a regular flat surface for EDX analysis. Finally, this approach correlating XPS and EDS represents a simple, fast and reliable way for characterizing the chemical composition and the homogeneity of industrial graphene. This study is part of the project ?Standardisation of structural and chemical properties of graphene? (ISO-G-SCoPe) which has received funding from the EMPIR programme co-financed by the Participating States and from the European Union?s Horizon 2020 research and innovation programme under Grant agreement No. 19NRM04. T2 - 2021 Fall Meeting of the European Materials Research Society (E-MRS) CY - Online meeting DA - 20.9.2021 KW - Graphene KW - XPS KW - EDS KW - Standardisation KW - Graphene functionalization PY - 2021 UR - https://www.european-mrs.com/meetings/2021-fall-meeting AN - OPUS4-53462 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chemello, Giovanni A1 - Despotelis, Konstantinos A1 - Paton, Keith A1 - Clifford, Charles A A1 - Pollard, Andrew A1 - Radnik, Jörg A1 - Hodoroaba, Vasile-Dan T1 - Approaches for the measurement of lateral dimensions of graphene oxide flakes using scanning electron microscopy N2 - There is a practical need, especially from the industrial community, to accurately measure the size and shape of graphene oxide (GO) flakes of commercial origin, in a reliable, simple, and unambiguous way. The sample preparation is a decisive step to obtain a homogeneous distribution of flakes on a substrate, which is suitable for image analysis. A certain level of inhomogeneity was still found but could be accepted for the purpose of this lateral size measurement study. A measurement procedure for Scanning Electron Microscopy (SEM) including sample preparation, measurement, image analysis and reporting was developed and validated to be applied for the lateral size analysis of “real-world” 2D flakes. Samples were produced for analysis by drop casting GO dispersions onto Si/SiO2 substrates. After SEM imaging, the images were analysed using two approaches to derive size and shape parameters. The influence of different operators has been evaluated. A maximum difference of 10% for the size descriptor and 2% for shape descriptor was found for both image analysis approaches when different samples of the same source material are measured and analysed by the same operator, hence indicating variability caused by sample preparation and analysing different sample areas. When different laboratories/operators perform the image analysis on exactly the same images and same flakes, the deviation found for the size descriptor is 2% and 4.6% corresponding to the two approaches applied, while no difference in the shape descriptor is observed. KW - Graphene oxide KW - SEM KW - Lateral dimension KW - Standardisation KW - Imaging PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625070 DO - https://doi.org/10.1088/2632-959X/adae28 VL - 6 IS - 1 SP - 1 EP - 11 PB - IOP Publishing AN - OPUS4-62507 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chemello, Giovanni A1 - Knigge, Xenia A1 - Ciornii, Dmitri A1 - Reed, B.P. A1 - Pollard, A.J. A1 - Clifford, C.A. A1 - Howe, T. A1 - Vyas, N. A1 - Hodoroaba, Vasile-Dan A1 - Radnik, Jörg T1 - Influence of the Morphology on the Functionalization of Graphene Nanoplatelets Analyzed by Comparative Photoelectron Spectroscopy with Soft and Hard X-Rays N2 - Since its isolation, graphene has received growing attention from academia and industry due to its unique properties. However, the “what is my material” barrier hinders further commercialization. X-ray photoelectron spectroscopy (XPS) is considered as a method of choice for the determination of the elemental and chemical composition. In this work the influence of the morphology of graphene particles on the XPS results is studied and investigated as a function of X-ray energy, using conventional XPS with Al K𝜶 radiation and hard X-ray photoemission spectroscopy (HAXPES) using Cr K𝜶 radiation. Thereby, the information depth is varied between 10 and 30 nm. For this purpose, two commercial powders containing graphene nanoplatelets with lateral dimensions of either ≈100 nm or in the micrometer range are compared. These larger ones exist as stack of graphene layers which is inspected with scanning electron microscopy. Both kinds of particles are then functionalized with either oxygen or fluorine. The size of the graphene particles is found to influence the degree of functionalization. Only the combination of XPS and HAXPES allows to detect the functionalization at the outermost surface of the particles or even of the stacks and to provide new insights into the functionalization process. KW - Functionalized graphene KW - Hard-energy X-ray photoelectron spectroscopy KW - X-ray photoelectron spectroscopy PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-578860 DO - https://doi.org/10.1002/admi.202300116 SN - 2196-7350 SP - 1 EP - 8 PB - Wiley VCH AN - OPUS4-57886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chemello, Giovanni A1 - Radnik, Jörg A1 - Hodoroaba, Vasile-Dan T1 - XPS–SEM/EDS Tandem Analysis for the Elemental Composition of Functionalized Graphene Nanoplatelets N2 - Over the past decade, energy-dispersive X-ray spectrometry (EDS) with scanning electron microscopy (SEM) has advanced to enable the accurate analysis of light elements such as C, N, or O. For this reason, EDS is becoming increasingly interesting as an analytical method for the elemental analysis of functionalized graphene and could be an attractive alternative to Xray photoelectron spectroscopy (XPS), which is considered the most important method for elemental analysis. In this study, comparative XPS and EDS investigations under different excitation conditions are carried out on commercially available powders containing graphene particles with different morphologies. The slightly different XPS/HAXPES and EDS results can be explained by the different information depths of the methods and the functionalization of the particle surfaces. For the material with smaller graphene particles and higher O/C ratios, all methods reported a lower O/C ratio in pellets compared with the unpressed powder samples. This clearly shows that sample preparation has a significant influence on the quantification results, especially for such a type of morphology. Overall, the study demonstrates that EDS is a reliable and fast alternative to XPS for the elemental quantification of functionalized graphene particles, provided that differences in the information depth are taken into account. Particle morphology can be examined in parallel with quantitative element analysis, since EDS spectrometers are typically coupled with SEM, which are available in a huge number of analytical laboratories. KW - Graphene oxide KW - SEM/EDS KW - XPS/HAXPES KW - Elemental composition KW - Functionalization PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-647294 DO - https://doi.org/10.1021/acsomega.5c07830 SN - 2470-1343 SP - 1 EP - 7 PB - American Chemical Society (ACS) AN - OPUS4-64729 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chemello, Giovanni A1 - Radnik, Jörg A1 - Hodoroaba, Vasile-Dan T1 - Analysis of Industrial Graphene-Based Flakes – First Results on Morphological Characterization, Sample Preparation and Chemical Composition N2 - In order to bridge the gap between lab-scale and industrial-scale production of graphene it is necessary to develop processes, equipment and measurement procedures to control the material features. One of the crucial reasons of graphene’s limited commercialization is the lack of standard procedures to properly characterize and define the material chemical and structural properties down to the nanometer level. This leads to many issues regarding material synthesis repeatability, inappropriateness choice of measurands and measurement reproducibility which heavily affect the consistency of the material performance. In our study, a comparative analysis is performed on two different series (G5 and G6) of industrial graphene powders, each series produced with four types of functionalization: raw graphene, oxygen-functionalized, nitrogen-functionalized and fluorine-functionalized. All the 8 sample variants were analyzed from a chemical and morphological point of view in the form of powders prepared as slightly pressed in metallic sample holders. The results of the comparative chemical analyses XPS and EDS show a good agreement in the concentration values for all the elements present in the samples, despite the different analysis volumes addressed by the two techniques. For this reason, the samples can be considered homogeneous in both lateral and vertical direction. A clear influence of the morphology on the composition is evident. Therefore, such correlative measurements of morphology and composition are necessary for a comprehensive characterization of industrial graphene flakes. KW - Graphene powder KW - XPS KW - HAXPES KW - SEM KW - EDS KW - Functionalized graphene PY - 2022 DO - https://doi.org/10.1017/S1431927622004342 SN - 1435-8115 VL - 28 IS - Suppl 1 SP - 1006 EP - 1008 PB - Cambridge University Press CY - New York, NY AN - OPUS4-55512 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chen, Z. A1 - Perez, J. P. H. A1 - Smales, Glen Jacob A1 - Blukis, R. A1 - Pauw, Brian Richard A1 - Stammeier, J. A. A1 - Radnik, Jörg A1 - Smith, A. J. A1 - Benning, L. G. T1 - Impact of organic phosphates on the structure and composition of short-range ordered iron nanophases N2 - Organic phosphates (OP) are important nutrient components for living cells in natural environments, where they readily interact with ubiquitous iron phases such as hydrous ferric oxide, ferrihydrite (FHY). FHY partakes in many key bio(geo)chemical reactions including iron-mediated carbon storage in soils, or iron-storage in living organisms. However, it is still unknown how OP affects the formation, structure and properties of FHY. Here, we document how β-glycerophosphate (GP), a model OP ligand, affects the structure and properties of GP–FHY nanoparticles synthesized by coprecipitation at variable nominal molar P/Fe ratios (0.01 to 0.5). All GP–FHY precipitates were characterized by a maximum solid P/Fe ratio of 0.22, irrespective of the nominal P/Fe ratio. With increasing nominal P/Fe ratio, the specific surface area of the GP–FHY precipitates decreased sharply from 290 to 3 m2 g−1, accompanied by the collapse of their pore structure. The Fe–P local bonding environment gradually transitioned from a bidentate binuclear geometry at low P/Fe ratios to monodentate mononuclear geometry at high P/Fe ratios. This transition was accompanied by a decrease in coordination number of edge-sharing Fe polyhedra, and the loss of the corner-sharing Fe polyhedra. We show that Fe(III) polymerization is impeded by GP, and that the GP–FHY structure is highly dependent on the P/Fe ratio. We discuss the role that natural OP-bearing Fe(III) nanophases have in biogeochemical reactions between Fe–P and C species in aquatic systems. KW - Organic phosphates KW - Iron nanophases KW - Scattering KW - Diffraction KW - Nanomaterials KW - Coprecipitation KW - Carbon storage PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-599399 DO - https://doi.org/10.1039/d3na01045g SN - 2516-0230 SP - 1 EP - 13 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-59939 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chudoba, T. A1 - Schwenk, D. A1 - Reinstädt, P. A1 - Griepentrog, Michael T1 - High-Precision Calibration of Indenter Area Function and Instrument Compliance N2 - The accuracy and comparability of nanoindentation results depend significantly on the calibration of area function and instrument compliance. The area function results should not depend on the reference material used or on the calibration method (direct or indirect). This has been investigated for 18 different Berkovich tips. A novel calibration method is proposed that confirms the material independence of the area function and gives a force-dependent instrument compliance function. An agreement between direct and indirect calibration could only be achieved by considering a radial displacement correction. Further, it is shown that the transition range from a spherical cap to the correct face angle of the pyramid can extend to a depth of more than 250 nm. A better parameter for the indenter than the tip radius is the offset of the contact radius to the radius of an ideal tip at a depth where the correct face angle is reached. KW - Nanoindentation KW - Calibration KW - Indenter area function KW - Instrument compliance PY - 2022 DO - https://doi.org/10.1007/s11837-022-05291-3 SN - 1047-4838 VL - 74 IS - 6 SP - 2179 EP - 2194 PB - Springer AN - OPUS4-55849 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Testing the quality of nanomaterial properties data for nano-risk assessment – towards guidance for all types of users N2 - Data quality is a vast term, which comprises the completeness, relevance (adequacy), and reliability of data. So far, many attempts to assure data quality have been pursued, and evaluation criteria for data quality have been established. One relatively novel but already well-known aspect of data quality refers to the concept of data FAIRness, which states that data should be: findable, accessible, interoperable and re-usable. In order to find, use, and access data, a user has to be guided properly. Such guidelines already exist for regulators and the scientific community. However, a ‘simple’ non-academic user from general society is very unlikely to be able to access or understand such data. Our objective in the H2020 project NANORIGO is to help and guide all types of users (i.e., scientists, regulators, industry workers, citizens, etc.) to access and make use of high-quality data and information from available and suitable data repositories in order to increase the transparency of and trust in nanotechnology. T2 - nanoSAFE 2020 CY - Online Meeting DA - 16.11.2020 KW - Nano-related data KW - Nanomaterial properties KW - Nano-risk assessment PY - 2020 AN - OPUS4-51701 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Micro- and Nanoplastics: from physico-chemical properties to reference products N2 - In this presentation we demonstrate the importance of physico-chemical properties (pc) of micro- and nanoplastic particles (MNPs). These properties determine interaction between MNPs and cells or living organisms. To perform accurate experiments for acquiring pc information it is essential to develop well-characterized and understood plastic reference materials. Such reference materials can be used in interlaboratory comparisons (ILCs). BAM is organizing under VAMAS two ILCs, on micro- and nanoplastics to obtain reliable results and methodologies for pc characterization of MNPs. By gaining profound knowledge on pc properties it becomes possible to estimate the impact of MNPs on the humans and environment and therefore to translate the knowledge to the level of regulation. T2 - CUSP early-stage researchers meeting CY - Online meeting DA - 08.11.2022 KW - Micro- and nanoplastics KW - Plastic reference materials KW - Interlaboratory Comparisons PY - 2022 AN - OPUS4-56330 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Validation of microplastics detection methods and proficiency testing: Suitable microplastic reference materials for interlaboratory comparison N2 - Since microplastics (MPs) can be found everywhere and are becoming a problem of high concern, it is necessary to understand their physico-chemical properties. To obtain reliable analytical data a set of validated methods for sampling, sample preparation, detection, and data evaluation are needed. To meet these needs an interlaboratory comparison (ILC) with 84 participants worldwide has been organized under the international pre-standardisation platform VAMAS (www.vamas.org/twa45/) as Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods” within the Technical Working Area TWA 45 “Micro and Nano Plastics in the Environment”. In this ILC thermo-analytical methods (Py-GC/MS and TED-GC/MS) and vibrational methods (µ-Raman and µ-FTIR) have been tested and compared by providing a set of microplastic representative test materials and measurement protocols developed at BAM. The defined measurands were: particle number concentration, particle size distribution (PSD), and polymer identity and mass content. To increase the statistical quality, 6 samples were shipped together with blank samples. Hence, the ILC provides information on precision and accuracy of the results obtained with different methods as well as strengths and limitations of the proposed protocols. T2 - SETAC 34th Meeting CY - Seville, Spain DA - 05.05.2024 KW - ILC KW - Microplastic KW - Method validation KW - Stakeholder KW - Reference materials KW - Polyethylene KW - Polyethylene Terephtalate PY - 2024 AN - OPUS4-60039 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Interlaboratory comparisons for obtaining reliable data on microplastic detection methods N2 - Since microplastics (MPs) can be found everywhere and are becoming a problem of high concern, it is necessary to understand their occurrence and fate in the environment. However, to obtain data of high quality is very challenging, since measurement operating procedures differ from laboratory to laboratory. Currently, there are no standardized methods to analyze microplastics. One promissing possibility to adress standardization of the methodology and operating procedures are interlaboratory comparisons (ILCs). In this contribution we report the first results of an ILC on microplastic detection methods organized under the pre-stantdardisation plattform of VAMAS (www.vamas.org/twa45/) as Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods”, within the Technical Working Area TWA 45 “Micro and Nano Plastics in the Environment”. The ILC has gathered 84 participants all over the world representing all continents. BAM, as the project leader, produced a set of reference microplastic materials, which have been distributed to all the participants together with the measurement protocols and reporting data templates. T2 - SETAC 34th Meeting CY - Seville, Spain DA - 05.05.2024 KW - ILC KW - Microplastic KW - Py-GC/MS KW - Polyethylene KW - µ-Raman KW - µ-FTIR KW - Polyethylene Terephtalate KW - TED-GC/MS PY - 2024 AN - OPUS4-60038 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Identification of toxicologically relevant functional groups on micro- and nanoplastic particles’ surface by means of X-Ray photoelectron spectroscopy N2 - Microplastic and nanoplastic particles (MNP) are spread all over the world in various types, shapes and sizes making it very challenging to accurately analyse them. Each sampling procedure, sample preparation method and detection technique needs suitable reference materials to validate the method for accurate results. Furthermore, the effects of these MNPs should be evaluated by risk and hazard assessment with test particles close to reality. To better understand MNP behavior and aid in clarification of their interactions with organisms, we produced several MNP materials by top-down procedure and characterized their properties. Since surface properties mostly determine particles’ toxicity, the aim of the present study was to determine which functional groups are present on MNPs and how the surface can be affected by the production process and particle’s environment. T2 - SETAC 34th Meeting CY - Seville, Spain DA - 05.05.2024 KW - Microplastics KW - Nanoplastics KW - Polypropylene KW - XPS KW - SEM PY - 2024 AN - OPUS4-60037 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Data quality for Nanorisk Governance N2 - Nanomaterials bring various benefits and have become a part of our daily lives. However, the risks emerging from nanotechnology need to be minimized and controlled at the regulatory level and therefore, there is a need for nanorisk governance. One of the prerequisites for successful nanorisk governance is the availability of high-quality data on nanomaterials and their impact with the human body and the environment. In recent decades, a countless number of publications and studies on nanomaterials and their properties have been produced due to the fast development of nanotechnology. Despite such a vast amount of data and information, there are certain knowledge gaps hindering an efficient nanorisk governance process. Knowing the state of the available data and information is an important requirement for any decision maker in dealing with risks. In the specific case of nanotechnology, where most of the risks are complex, ambiguous, and uncertain in nature, it is essential to obtain complete data and metadata, to fill knowledge gaps, and to transform the available knowledge into functional knowledge. This can become possible using a novel approach developed within the NANORIGO project (Grant agreement No. 814530) – the Knowledge Readiness Level (KaRL). In analogy to NASA’s Technology Readiness Levels (TRLs), we define KaRLs as a categorization system of data, information, and knowledge which enables transformation of data and information into functional knowledge for nanorisk governance. Our approach goes beyond the technical curation of data and metadata and involves quality and completeness filters, regulatory compliance requirements, nanorisk-related tools, and most importantly, human input (inclusion of all stakeholder groups). With the KaRL approach we also address key issues in nanotechnology such as societal and ethical concerns, circular economies and sustainability, the Green Deal, and the traceability of data, knowledge, and decisions. The KaRL approach could be used for nanorisk governance by a nanorisk governance council (NRGC), which is currently under development by three EU projects (NANORIGO, GOV4NANO, and RISKGONE). T2 - Nanosafety Training School: From Basic Science To Risk Governance CY - Online meeting DA - 20.06.2021 KW - Data KW - Knowledge KW - Risk Governance KW - Knowledge Readiness Level PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529255 AN - OPUS4-52925 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Knowledge Readiness for Nanorisk Governance N2 - Nanomaterials bring various benefits and have become a part of our daily lives. However, the risks emerging from nanotechnology need to be minimized and controlled at the regulatory level and therefore, there is a need for nanorisk governance. One of the prerequisites for successful nanorisk governance is the availability of high-quality data on nanomaterials and their impact with the human body and the environment. In recent decades, a countless number of publications and studies on nanomaterials and their properties have been produced due to the fast development of nanotechnology. Despite such a vast amount of data and information, there are certain knowledge gaps hindering an efficient nanorisk governance process. Knowing the state of the available data and information is an important requirement for any decision maker in dealing with risks. In the specific case of nanotechnology, where most of the risks are complex, ambiguous, and uncertain in nature, it is essential to obtain complete data and metadata, to fill knowledge gaps, and to transform the available knowledge into functional knowledge. This can become possible using a novel approach developed within the NANORIGO project (Grant agreement No. 814530) – the Knowledge Readiness Level (KaRL). In analogy to NASA’s Technology Readiness Levels (TRLs), we define KaRLs as a categorization system of data, information, and knowledge which enables transformation of data and information into functional knowledge for nanorisk governance. Our approach goes beyond the technical curation of data and metadata and involves quality and completeness filters, regulatory compliance requirements, nanorisk-related tools, and most importantly, human input (inclusion of all stakeholder groups). With the KaRL approach we also address key issues in nanotechnology such as societal and ethical concerns, circular economies and sustainability, the Green Deal, and the traceability of data, knowledge, and decisions. The KaRL approach could be used for nanorisk governance by a nanorisk governance council (NRGC), which is currently under development by three EU projects (NANORIGO, GOV4NANO, and RISKGONE). T2 - Gov4Nano: data management core group CY - Online meeting DA - 05.07.2021 KW - Data Management KW - Knowledge Readiness Level KW - Nanorisk Governance KW - Participatory Approach KW - Sustainability PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529264 AN - OPUS4-52926 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Knowledge Readiness Level (KaRL) approach for nanorisk governance and beyond N2 - Regulatory decisions require reliable data and knowledge derived from this. Among stakeholders in nanotechnology, however, there is often uncertainty about the quality of data for regulatory purposes. In addition, the general public often finds itself excluded from nanoregulation and policy decisions. This creates uncertainty in the nanotechnology field and also in other branches of technology and leads to concerns among the society. To address these issues, NANORIGO elaborates a framework to support decision making as well as data, information and knowledge sharing and use. We refer to “reliability” of data and knowledge as a degree of readiness or maturity. According to these criteria we worked out a 9-level scale in analogy to TRL (technology readiness level), the KaRL system (Knowledge, Data and Information Readiness Level). KaRL allows assessment of knowledge readiness for decision making by applying defined quality criteria for each level. It also provides guidance on how to enhance the readiness level by the help of available tools and procedures. KaRL addresses SEIN[1] principles, circular economy and thus involves the public concerns in regulation. A specialized nanorisk governance council (being under development in NANORIGO) is suggested to perform quality check of an actionable document, thus, aiding in consensus on the reliability (maturity) of knowledge for decision making. Moreover, KaRL facilitates traceability of knowledge before its use in decision making. This enables the transparency demanded by all stakeholders. T2 - EuroNanoForum 2021 CY - Online meeting DA - 05.05.2021 KW - Knowledge Readiness Level KW - Nanorisk KW - Nanomaterials KW - Data PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-524725 AN - OPUS4-52472 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Knowledge, Information and Data Readiness Levels (KaRL) approach for Nanorisk Governance N2 - Nanomaterials may have brought many beneficial innovations with them in our daily lives and and have become indispensable for the society. However, one needs to be concerned of the risks which are still unknown and not sufficietly studied and therefore there is a need for a nanorisk governance. At the core of nanorisk governance is gathering, processing and analysing reliable data which will be used for decision making. The challenge is to assure data reliability and transform it into knowledge. To address this challenge, we used analogy to technology readiness level (TRL) approach (developed by NASA), and elaborated knowledge readiness level (KaRL). KaRL is a nine-scale system to categorize data and knowledge (documents) into levels of readiness for particular purposes and to enhance readiness level by using quality and completeness filters, compliance requirements, nanorisk-related tools, stakeholders’ input. By our approach we addressed key issues in nanotechnology such as societal and ethical concerns, circular economy and sustainability, traceability of data, knowledge and decisions. T2 - EC - HORIZON EUROPE NMBP-13 Joint Conference Risk Governance of nanotechnology CY - Online meeting DA - 12.04.2021 KW - Knowledge Readiness Level KW - Nanorisk KW - Nanomaterials KW - Data PY - 2021 AN - OPUS4-52471 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Interlaboratory Comparisons – ILCs (2022-2023) N2 - To obtain reliable data on micro- and nanoplastics (MPs, NPs) BAM (Federal Institute for Materials Research and Testing) is organizing interlaboratory comparisons (ILCs). Main focus is detection and physico-chemical characterisation. The accuracy and precision of the results of different laboratories and comparability of the results among the participants are addressed. The ILCs will be performed in the following order: i) ILC #1: Detection and Characterisation of MPs (1-1000 µm) and ii) ILC #2: Detection and Characterisation of NPs (< 1 µm). For the ILC #1 the parameters to be analysed are: particle size distribution, shape, mass content, particle concentration, with thermoanalytic (Py-GC/MS, TED-GC/MS) and spectroscopy (µ-Raman, µ-FTIR) methods. For the ILC #2 the parameters are: particle size distribution, shape, particle concentration, with methods such as spectroscopical (Raman), Electron Microscopies (SEM, AFM), etc. Exact measurands and methods are still under discussion. BAM will provide test materials of well-known stability and homogeneity. ILC participants will include partners of the CUSP (the European research cluster to understand the health impacts of micro- and nanoplastics), and any other institutions over the world. The ILCs will take place under the international pre-standardisation platform VAMAS, new Technical Working Area 35 “Micro and Nano Plastics in the Environment” (http://www.vamas.org/twa45/). T2 - Progressing Together: 2nd CUSP Annual Meeting at the JRC (Ispra) CY - Ispra, Italy DA - 08.06.2022 KW - ILC KW - Micro- and nanoplastics KW - VAMAS KW - Analytical methods PY - 2022 AN - OPUS4-55097 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ciornii, Dmitri T1 - Getting reliable data on microplastic detection methods by means of ILC N2 - There is an urgent demand for reliable data on microplastic analysis, particularly on its physico-chemical properties as well as validated methodology to obtain such data. Through interlaboratory comparisons (ILCs) it becomes possible to assess accuracy and precision of methods by involving many laboratories around the world. At BAM, my tasks focused around organisation of an ILC on physico-chemical characterisation of microplastic detection methods under the international pre-standardisation platform VAMAS (www.vamas.org/twa45/) as Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods” under the Technical Working Area TWA 45 “Micro and Nano Plastics in the Environment”. With a proud number of 84 participants this ILC is able to provide superior statistical results. Thermoanalytical (Py-GC/MS and TED-GC/MS) and vibrational (µ-IR and µ-Raman) methods were asked for identification and quantification of microplastic test samples according to mass or particle number. Preliminary results indicate which methods show a higher accuracy and precision and reveal some sample preparation ideas which work best for microplastics characterisation. At the end of the ILC an overall plausibility of the results will be assessed. T2 - CUSP Early Career Researchers Meeting CY - Online meeting DA - 21.11.2023 KW - Micro- and Nanoplastics KW - Interlaboratory comparison KW - Microplastic reference materials PY - 2023 AN - OPUS4-59056 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Ciornii, Dmitri A1 - Hodoroaba, Vasile-Dan A1 - Benismail, Nizar A1 - Altmann, Korinna T1 - Project 2: Interlaboratory Comparison on detection and quantitative assessment of microplastics by use of spectroscopic and thermo-analytical methods N2 - Validated and standardized methods in microplastic analysis are indispensable for robust monitoring and regulation. Alongside also reference materials are urgently needed. An interlaboratory comparison (ILC) offers a powerful tool to address both these challenges. The present study aimed to compare the precision and accuracy of various methods for the detection and quantification of microplastic in a water-soluble matrix. Additionally, it evaluated the suitability of the test materials (containing environmentally relevant plastic polymers) to serve as reference materials for the microplastic analysis. In this ILC several most used thermo-analytical and spectroscopic methods have been addressed: Pyrolysis-Gas Chromatography Mass Spectrometry (Py-GC/MS), Thermal Extraction-Desorption Gas Chromatography Mass Spectrometry (TED-GC/MS), micro-Fourier Transform Infrared Spectroscopy (µ-FTIR), and micro-Raman Spectroscopy and Laser Direct Infrared Spectroscopy (LDIR). Microplastic powders of polyethylene (PE) and polyethylene terephthalate (PET) were used to assess suitability of the test materials (microplastic tablets) for method validation and use in the ILCs. The participants were guided with a SOP how to dissolve the test samples and, depending on their selected method, either quantify the number of particles (by the spectroscopic methods) or determine the mass fraction of microplastic particles per sample (by the thermo-analytical methods). KW - ILC KW - Microplastic KW - FTIR KW - Raman KW - TED-GC/MS KW - Py-GC/MS PY - 2024 SP - 1 EP - 16 AN - OPUS4-60612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -