TY - CONF A1 - Legall, Herbert A1 - Bonse, Jörn A1 - Krüger, Jörg T1 - Emission of X-rays during ultrashort pulse laser processing N2 - Ultrashort pulse laser materials processing can be accompanied by the production of X-rays. Small doses per laser pulse can accumulate to significant dose rates at high laser pulse repetition rates which may exceed the permitted X-ray limits for human exposure. Consequently, a proper radiation shielding must be considered in laser machining. A brief overview of the current state of the art in the field of undesired generation of X-ray radiation during ultrashort pulse laser material processing in air is presented. T2 - Lasers in Manufacturing Conference 2021 CY - Online meeting DA - 21.06.2021 KW - Ultra-short pulse laser processing KW - Laser-induced X-ray emission KW - Radiation protection PY - 2021 SP - 1 EP - 5 AN - OPUS4-53866 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Baier, Jennifa A1 - Fischer, Daniel A1 - Griepentrog, Michael A1 - Hertwig, Andreas A1 - Hielscher-Hofinger, Stefan A1 - Stockmann, Jörg Manfred A1 - Weise, Matthias T1 - Mapping und Imaging modifizierter Oberflächen: Generische Kenngrößen, Fehlstellen, Reinigungszustand und Haftfestigkeit N2 - Der Vortrag widmet sich dem Mapping und Imaging modifizierter Oberflächen: generische Kenngrößen, Fehlstellen, Reinigungszustand und Haftfestigkeit. Es werden Untersuchungsmethoden zu ihrer Prüfung dargestellt. T2 - 37. ak-adp 2021 CY - Jena, Germany DA - 16.06.2021 KW - Qualitätssicherung KW - Mapping modifizierter Oberflächen KW - Imaging modifizierter Oberflächen KW - Generische Kenngrößen KW - Haftfestigkeit KW - Klebfestigkeit PY - 2021 SP - 1 EP - 10 AN - OPUS4-52893 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Hufschläger, Daniel A1 - Gohlke, Dirk A1 - Weise, Matthias A1 - Ilse, D. A1 - Hillger, W. A1 - Szewieczek, A. T1 - Thermoakustische und Ferroelektret-Wandler als Phased-Array-Sender für luftgekoppelte Ultraschallprüfung N2 - Die üblichen Verfahren der zerstörungsfreien Prüfung mit Ultraschall basieren auf der Verwendung von flüssigen Koppelmitteln. Luftgekoppelte Prüfung setzt sich gegen die konventionellen Verfahren durch, wenn die Flüssigkeit nicht erwünscht oder den Prüfling gar beschädigen kann. Zwei Technologien für Erzeugung von Ultraschallsignalen sind vielversprechend: thermoakustische Wandler und Ferroelektret-Wandler. Basierend auf diesen beiden Technologien wurden Array-Sender gebaut und in diesem Beitrag miteinander verglichen. Thermoakustische Wandler basieren auf Dünnschichttechnologie und bieten eine resonanzfreie Erzeugung von Ultraschall. Sie bestehen aus einer dünnen elektrisch leitenden Schicht und werden mit kurzen elektrischen Pulsen angeregt. Die Erhöhung der thermischen Energie führt zur Erzeugung von akustischen Wellen in der umgebenden Luft. Bei Ferroelektret-Wandlern handelt es sich um polarisierte zelluläre Kunststoffe, die für den Bau eines Array-Senders besonders gut geeignet sind. Einige Ferroelektrete weisen eine hervorragende an Luft angepasste akustische Impedanz auf, so dass auf den Einsatz von Anpassschichten verzichtet werden kann. Ein sehr niedriges mechanisches Übersprechen zwischen einzelnen Elementen ermöglicht eine unabhängige Anregung einzelner Elemente, was bei Piezokompositen deutlich schwieriger wäre. Mit der Phased-Array-Technik können elektronische Fokussierung oder Schwenkung des Einschallwinkels für eine luftgekoppelte Prüfung genutzt werden. Die Schallfelder von diesen beiden Technologien wurden berechnet, gemessen und miteinander verglichen. Die Vorteile und Nachteile der beiden Technologien werden dargestellt. T2 - DAGA 2023 Jahrestagung für Akustik CY - Hamburg, Germany DA - 06.03.2023 KW - Luftgekoppelte Ultraschallprüfung KW - Thermoakustik KW - Ferroelektret KW - Phased Array PY - 2023 UR - https://pub.dega-akustik.de/DAGA_2023 SN - 978-3-939296-21-8 SP - 1594 EP - 1597 AN - OPUS4-57554 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Hufschläger, Daniel A1 - Gohlke, Dirk A1 - Weise, Matthias A1 - Ilse, D. A1 - Hillger, W. A1 - Szewieczek, A. T1 - Phased-Array-Prüfköpfe für luftgekoppelte Ultraschallprüfung auf Basis von zellulären Kunststoffen N2 - Luftgekoppelte Ultraschallprüfung setzt sich immer häufiger gegen die konventionelle Ultraschallprüfung von Leichtbaukomponenten durch, und zwar in vielen Industriezweigen von der Holzindustrie bis zur Luftfahrt. Während die Phased-Array-Technik mittlerweile zu dem industriellen Standard im Bereich der Prüfung mit Ankopplung gehört, wird luftgekoppelte Ultraschallprüfung meist mit zwei Wandlern in Durchschallung durchgeführt. Deswegen werden Vorteile der Phased-Array-Technik wie beispielsweise elektronische Fokussierung oder Schwenkung des Einschallwinkels für luftgekoppelte Prüfung selten genutzt. In diesem Beitrag werden die laufenden Arbeiten an der Entwicklung eines neuen Phased-Array-Geräts vorgestellt, mit dem Schwerpunkt an der Charakterisierung der Prüfköpfe und ihrer Schallfelder. Das Gerät besteht aus einem linearen Phased-Array-Prüfkopf, einer Sende- und einer Empfangseinheit. Die Hauptinnovation unserer Arbeit ist die Anwendung von zellulären Kunststoffen für den Bau eines Arrays, wobei der Sender mit Hochspannung von ca. 1500 V angeregt wird. Geladene zelluläre Polymere werden auch Ferroelektrete oder Piezoelektrete genannt. Sie weisen ein sehr niedriges Elastizitätsmodul und dadurch eine niedrige akustische Impedanz auf, so dass auf den Einbau von Anpassschichten verzichtet werden kann. Eine sehr niedrige mechanische Kreuzkopplung bei Ferroelektreten ermöglicht eine unabhängige Anregung einzelner Elemente, was bei Piezokompositen deutlich schwieriger wäre. Die Entwicklung der Array-Prüfköpfe wurde durch Berechnungen des Schallfeldes unterstützt, die auf Punktquellensynthese basieren. Die beabsichtigte Anwendung von Phased-Array-Prüfköpfen und des Prüfsystems sind die Durchschallung mit Fokussierung, elektronischer Scan und die Schwenkung des Einschallwinkels zur Anregung von geführten Wellen, angewandt an carbonfaserverstärkten Kunststoffen und ähnlichen Materialien. Die Anwendung von geführten Wellen bietet die Perspektive, Bauteile mit einseitiger Zugänglichkeit zu prüfen. T2 - DACH-Jahrestagung 2023 CY - Friedrichshafen, Germany DA - 15.05.2023 KW - Luftgekoppelte Ultraschallprüfung KW - Ferroelektret KW - Ultraschallwandler KW - Phased Array PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575564 SP - 1 EP - 6 AN - OPUS4-57556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hufschläger, Daniel A1 - Gohlke, Dirk A1 - Weise, Matthias A1 - Bente, K. A1 - Gaal, Mate T1 - Thermoakustische Gruppenstrahler: Theorie und Anwendungen N2 - Bei der Prüfung von Werkstücken mit empfindlichen Oberflächen oder auch hydrophilen Werkstoffen sind traditionelle ultraschallbasierte zerstörungsfreie Prüfmethoden wie die Kontakttechnik oder die Tauchtechnik in vielen Anwendungsfällen aufgrund der Flüssigkeitsankopplung nicht anwendbar. Die luft-gekoppelte Ultraschallprüfung umgeht diese Problematik und eröffnet neue Prüfszenarien. Derzeit werden zwei Varianten der Schallerzeugung als vielversprechend angesehen: ferroelektrische Folien und thermoakustische Dünnschichtwandler. Thermoakustische Wandler ermöglichen die resonanzfreie Erzeugung von Ultraschall und somit kurze zeitliche Impulse sowie eine sehr breitbandige Anregung. Durch die Verwendung von gekrümmten Substraten ist sowohl eine Herstellung von planaren als auch fokussierten Wandlern möglich. Dieser Beitrag präsentiert die letzten Forschungsergebnisse im Bezug auf thermoakustischen Wandlern, welche derzeit in einen thermoakustischen Gruppenstrahler münden. Gruppenstrahler erlauben die simultane Änderung des Einschallwinkels, sowie die Verschiebung des Fokuspunktes während der Verwendung. Durch die Verbindung beider Schlüsseltechnologien, der thermoakustischen Anregung und des Gruppenstrahlerprinzips, wird das Spektrum der klassischen ZfP-Anwendungen, sowie moderner Ansätze wie der Anregung von geführten Wellen oder der Strukturüberwachung erheblich erweitert und bereichert. Dabei soll innerhalb dieses Beitrages auf die Modellierung des Schallfeldes, die elementweise Charakterisierung und verschiedene Anwendungsszenarien eingegangen werden. T2 - DACH-Jahrestagung 2023 CY - Friedrichshafen, Germany DA - 15.05.2023 KW - Luftgekoppelte Ultraschallprüfung KW - Thermoakustik KW - Ultraschallwandler KW - Phased Array PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575599 SP - 1 EP - 6 AN - OPUS4-57559 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grundmann, Jana A1 - Ermilova, Elena A1 - Hertwig, Andreas A1 - Klapetek, Petr A1 - Pereira, Silvania F. A1 - Rafighdoost, Jila A1 - Bodermann, Bernd T1 - Optical and Tactile Measurements on SiC Sample Defects N2 - The different defect types on SiC samples are measured with various measurement methods including optical and tactile methods. The defect types investigated include particles, carrots and triangles and they are analyzed with imaging ellipsometry, coherent Fourier scatterometry and atomic force microscopy. Each of these methods measures different properties of the defects and they all together contribute to a complete analysis. T2 - SMSI 2023 - Sensor and Measurement Science International CY - Nuremberg, Germany DA - 08.05.2023 KW - Defects KW - Silicon carbide KW - Imaging ellipsometry KW - Atomic force microscopy KW - Coherent Fourier scatterometry PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-593397 SN - 978-3-9819376-8-8 DO - https://doi.org/10.5162/SMSI2023/D5.2 VL - 2023/D5 SP - 233 EP - 234 PB - AMA Service CY - Wunstorf AN - OPUS4-59339 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ermilova, Elena A1 - Weise, Matthias A1 - Hertwig, Andreas T1 - Hybrid optical measurement technique for detection of defects in epitaxially grown 4H-SiC layers N2 - Recent developments in power electronics require the use of new wide bandgap compound semiconductor. We demonstrate the use of the ellipsometry and white light interference microscopy to detect defects in epitaxially grown SiC layers on SiC substrates. Such hybrid optical metrology methods can be used to better understand the mechanism of the development of the defects as well as their effects on the material´s optoelectronic properties. T2 - EOS Annual Meeting (EOSAM 2022) CY - Porto, Portugal DA - 12.09.2022 KW - Imaging ellipsometry KW - White light interference microscopy KW - Wide bandgap compound semiconductor KW - Epitaxially grown 4H-SiC layers PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-561113 DO - https://doi.org/10.1051/epjconf/202226610001 VL - 266 SP - 1 EP - 2 AN - OPUS4-56111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Ahmadzadeh, Majid A1 - Weise, Matthias T1 - Focussed sound field of thermoacoustic transmitters N2 - The thermoacoustic effect offers a method for selectively exciting broadband and focused ultrasonic waves, which can be utilized in air-coupled ultrasonic testing of lightweight components that might otherwise sustain damage from liquid couplants. Thermoacoustic transmitters are composed of an electrically conductive layer deposited on an insulating substrate. When electrical pulses are applied, the conductive layer heats, briefly warming the adjacent air and inducing thermal expansion, which generates an acoustic wave. In testing applications, the thermoacoustic transmitter is positioned at the focal distance to the structure under examination, where the resolution of the resulting ultrasonic image is influenced by the focus diameter. To optimize imaging resolution, understanding the focusing characteristics of thermoacoustic transmitters is essential. In this study, thermoacoustic transmitters with an indium tin oxide (ITO) layer on a quartz glass substrate were developed. Geometrical parameters, including substrate curvature and conductive layer thickness, along with electrical excitation parameters, were systematically varied to investigate their impact on the sound field up to approximately 1 MHz. The results indicate that, among the parameters studied, substrate curvature exerts the most significant influence on the sound field. T2 - DAS-DAGA Tagung CY - Kopenhagen, Danmark DA - 17.03.2025 KW - Air-coupled ultrasound KW - Thermoacoustic transmitter KW - Focussed transducer PY - 2025 SP - 1 EP - 4 AN - OPUS4-63092 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Werner, Tiago A1 - Teske, Tanita A1 - Hilgenberg, Kai A1 - Mauro, Madia A1 - Nielsen, S. A1 - Gärtner, F. A1 - Klassen, T. T1 - Untersuchung des Potenzials von Kaltgasspritzen für die Reparatur zyklisch belasteter Bauteile T1 - Investigation on the capability of cold-spray for repair of cyclically loaded components N2 - Die Reparatur mittels Kaltgasspritzen ist eine vielversprechende Alternative zum teuren Austausch fehlerbehafteter Bauteile in der Luft- und Raumfahrt. Im Rahmen dieser Arbeit wurde das Potential des Verfahrens an der hochfesten Aluminiumlegierungen Al6061-T6 unter Anwendung von Stickstoff als kostengünstiges Prozessgas untersucht. Es wurden quasi-statische Zugversuche und einachsige Zeitfestigkeitsversuche mit besonderem Fokus auf das in-situ Kugelstrahlen zur Verbesserung der mechanischen Eigenschaften durchgeführt. Im Ergebnis wurde die Verbesserung der Adhäsion zwischen Substrat und aufgebautem Werkstoff als entscheidendes Kriterium für eine Anwendbarkeit ermittelt. Die Laserstrukturierung von Substratoberflächen ist hierfür vielversprechend und wurde im Rahmen der Arbeit mittels Adhäsionsversuchen untersucht. N2 - Repair by cold-spray is a promising alternative to the costly replacement of flawed components in aerospace applications. In the present work this process was investigated on the high-strength aluminum alloy Al6061-T6. For the cold-spray process, inexpensive Nitrogen was used as process-gas. Quasi-static tensile and highcycle- fatigue tests (HCF) were performed, focusing on in-situ shot peening to improve the mechanical properties of the repaired part. An improved adhesion between substrate and built-up material was identified as a key-factor for the applicability of the process. Under this respect laser-structuring of the substrate surface was applied and its effect on the mechanical performance of the restored samples were examined by adhesion tests. T2 - 9. Tagung des DVM-Arbeitskreises Additiv gefertigte Bauteile und Strukturen CY - Stuttgart, Germany DA - 06.11.2024 KW - Kaltgasspritzen KW - cold-spray KW - Reparatur KW - Repair KW - Ermüdungsfestigkeit KW - Fatigue KW - Luft- und Raumfahrt KW - Aerospace KW - Substratvorbehandlung KW - Substrate pre-treatment PY - 2024 DO - https://doi.org/10.48447/ADD-2024-BB VL - 409 SP - 67 EP - 79 AN - OPUS4-63182 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zubia Aranburu, Judith A1 - Cappella, Brunero A1 - Zabala Eguren, A. A1 - Buruaga Lamarain, L. A1 - Aginagalde Lopez, A. A1 - Bonse, Jörn A1 - Schwibbert, Karin T1 - Quantification of the adhesion force of E. coli on Ti via single-cell force spectroscopy N2 - Antibiotic resistance is a growing global problem which poses a massive threat to human health. Although human activity contributes to the acceleration of the process, bacteria have a self-driven stabilisation mechanism to protect themselves from such and other external threats: biofilm formation. Nonetheless, it is the adhesion of a single bacterial cell to a surface that triggers the formation of such network of biomolecules and microorganisms, as well as its hazardous consequences. The main objective of this work was to quantify the adhesion force of a single E. coli cell on a Ti substrate via the AFM-related single-cell force spectroscopy, with both the cell and the substrate material being of high clinical relevance. A set of 25 x 25 force displacement curves was acquired with a maximum force of 3.2 nN without dwell time, yielding a topography map and an adhesion force map that showed to be correlated. A mean adhesion force of 0.85 ± 0.175 nN was measured and the presence of cell appendages on the bacterial cell wall was verified through individual force-displacement curves. Bacterial viability was assessed after the measurements via live/dead staining. T2 - XL Congreso Anual de la Sociedad Española de Ingeniería Biomédica CASEIB 2022 CY - Valladolid, Spain DA - 23.11.2022 KW - Bacteria KW - Atomic force microscopy KW - Force distance curve PY - 2022 SN - 978-84-09-45972-8 SP - 217 EP - 220 AN - OPUS4-57039 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -