TY - CONF A1 - Beck, Uwe T1 - Functional coatings for mechanical applications: characterization and standardization N2 - The paper addresses the “Functional coatings for mechanical applications: characterization and standardization” and the following points are discussed in more detail: 1. Mechanic alapplications (coatings for tools and components, system features vs. material parameters) 2. Mechanical characterization (instrumented indentation testing (IIT), centrifugal adhesion testing (CAT), state of standardization) 3. Topometric characterization (white light interference microscopy (WLIM, 3D), mechanical stylus (MS, 2D), state of standardization) 4. Optical characterization (spectroscopic ellipsometry (SE), inter-laboratory comparison, state of standardization) T2 - IC-CMTP6 CY - Miskolc, Hungary DA - 04.10.2021 KW - Spectroscopic Ellipsometry KW - White Light Interference Microscopy KW - Instrumented Indentation Testing KW - Functional coatings KW - Mechanical characterization KW - Optical characterization KW - Topometric characterization KW - Standardization PY - 2021 AN - OPUS4-53987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - Mapping und Imaging modifizierter Oberflächen: Generische Kenngrößen, Fehlstellen, Reinigungszustand und Haftfestigkeit N2 - Der Vortrag widmet sich dem Mapping und Imaging modifizierter Oberflächen: Generische Kenngrößen, Fehlstellen, Reinigungszustand und Haftfestigkeit. Es werden Untersuchungsmethoden zu ihrer Prüfung dargestellt. T2 - 37. ak-adp 2021, Jena CY - Online meeting DA - 16.06.2021 KW - Qualitätssicherung KW - Mapping modifizierter Oberflächen KW - Generische Kenngrößen KW - Haftfestigkeit KW - Klebfestigkeit PY - 2021 AN - OPUS4-52870 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - From on line sensor validation to in-situ monitoring of layer growth: coatings around fibre bragg gratings N2 - The lack of on-line validation procedures for structure-embedded fiber-optical strain sensors, in particular fiber-Bragg-gratings (FBG), resulted in limited applications in structural health monitoring (SHM). Degradation under service conditions and ageing as a result of climatic influences or delamination under load were unsolved Validation issues. This could be overcome by means of an auto-diagnosis procedure based on FBG-sensors coated by electrochemical deposition (ECD) with a magnetostrictive NiFe-coating on top of an adhesive Cu/Cr adhesive layer deposited by physical vapour deposition (PVD) around the FBG strain sensor. This allows at any time under Service a validation of sensor functionality, stability, and reliability. For this purpose, a magnetic strain-proportional reference field is introduced. The optical read-out is realized by the measurement of the Bragg-wavelength shift. The ratio of resulting strain and exciting magnetic reference field should be constant given that the sensor is in proper function. In principle, the magnetostrictive coating around the FBG should also work as on-line magnetic field sensor and other applications in material science. One of these applications is the in-situ monitoring of ECD processes as the deposition of the ECD NiFe-layer on the FBG revealed. Challenges are the monitoring of temperature, deposition stages/thickness, and resulting mechanical stress under given plating conditions. Monitoring problems can be solved by applying a pre-coated FBG to the electrolytic process as the shift of the Bragg wavelength is affected by both the temperature of the electrolyte near the substrate and the stress formation in the growing layer. The experimental FBG set-up and the quantitative determination of temperature- and stress-related strain are described for a nickeliron electrolyte. The in-situ measurement of Bragg wavelength shifts of a pre-coated FBG during electrochemical deposition allows a detailed analysis of stress states due to changes in the growth morphology of the layer. The separation of mechanical and thermal contributions to this shift provides information on the individual Deposition processes in terms of a process fingerprint. T2 - ICMCTF 2021 San Diego/on-line CY - Online meeting DA - 28.04.2021 KW - Fiber- Bragg-gratings (FBG) KW - Physical vapour deposition (PVD) KW - Electrochemical deposition (ECD) KW - Magnetostrictive coating KW - ECD NiFe-layer PY - 2021 AN - OPUS4-52898 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - Proposal for revision of en 15870 „Adhesives determination of tensile strength of butt joints” N2 - The paper addresses the PROPOSAL FOR REVISION OF EN 15870 „ADHESIVES -DETERMINATION OF TENSILE STRENGTH OF BUTT JOINTS” “ and the follow points are discussed in more detail: Adhesives-Determination of tensile strength of butt joints, Introduction of Centrifugal Adhesion Testing, Comparison of Testing Methods. T2 - CEN TC 193 Madrid CY - Online meeting DA - 04.03.2021 KW - Centrifugal Adhesion Testing (CAT) KW - DIN EN ISO/IEC 17025 KW - Adhesives - Determination PY - 2021 AN - OPUS4-52900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - Uncertainty budgets in surface techno-logy: step height, layer thickness, indentation hardness, adehesive strength N2 - The object (sample) and the measurement/testing procedure may always have unknown degrees of freedom, i.e. instead of 𝐯 ≥ n – 1 in many cases 𝐯 ≫ n - 1 may apply, in particular in the micro- and nano-world! T2 - 10. VDI-Fachtagung, Messunsicherheit und Prüfprozesse CY - Erfurt, Germany DA - 10.11.2021 KW - Methodology in metrology KW - Methodology in testing KW - Spectroscopic Ellipsometry KW - Instrumented Indentation (IIT) KW - Centrifugal Adhesion Testing (CAT) PY - 2021 AN - OPUS4-53739 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe T1 - Materials testing using centrifuge technology a journey through time from 2004 to 2024 N2 - This presentation provides an overview of materials testing using centrifuge technology in the period from 2004 to 2024. The development, the proof of concept, the functional principle, various operating modes as well as applications and examples are shown. T2 - ICDAMT 2024 CY - Berlin, Germany DA - 10.06.2024 KW - Centrifuge technology KW - Materials testing KW - Centrifugal adhesion testing KW - Tensile and cmpressive stress testing PY - 2024 AN - OPUS4-60541 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Baier, Jennifa A1 - Fischer, Daniel A1 - Griepentrog, Michael A1 - Hertwig, Andreas A1 - Hielscher-Hofinger, Stefan A1 - Stockmann, Jörg Manfred A1 - Weise, Matthias T1 - Mapping und Imaging modifizierter Oberflächen: Generische Kenngrößen, Fehlstellen, Reinigungszustand und Haftfestigkeit N2 - Der Vortrag widmet sich dem Mapping und Imaging modifizierter Oberflächen: generische Kenngrößen, Fehlstellen, Reinigungszustand und Haftfestigkeit. Es werden Untersuchungsmethoden zu ihrer Prüfung dargestellt. T2 - 37. ak-adp 2021 CY - Jena, Germany DA - 16.06.2021 KW - Qualitätssicherung KW - Mapping modifizierter Oberflächen KW - Imaging modifizierter Oberflächen KW - Generische Kenngrößen KW - Haftfestigkeit KW - Klebfestigkeit PY - 2021 SP - 1 EP - 10 AN - OPUS4-52893 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe A1 - Ermilova, Elena A1 - Schneider, S. A1 - Peters, S. T1 - Gemeinsamer Abschlussbericht WIPANO-Vorhaben „Standardisierung und Normung der Ellipsometrie als universeller Spektroskopie“ N2 - Im Vorhaben SNELLIUS wurden in enger Zusammenarbeit der BAM mit den Firmen Accurion und SENTECH Instruments aufbauend auf der Norm DIN 50989-1 „Ellipsometrie - Teil 1: Grundlagen; Ellipsometry – Part 1: Principles“ insgesamt fünf Normenentwürfe erarbeitet, die fünf Modell-basierten Anwendungsfällen der Ellipsometrie entsprechen. Unter Berücksichtigung des neuartigen Modell-basierten Normungskonzepts wurde in den Normenentwürfen erstmals eine GUM- und DIN EN ISO/IEC 17025:2018 konforme Bestimmung bzw. Abschätzung der Messunsicherheit umgesetzt. Dies erforderte neben der textlichen Erstellung auch umfangreiche experimentelle Arbeiten bei den Firmen, Vergleichsversuche und komplementäre Modell- und Datenevaluierungen, da sowohl die verwendete ellipsometrische Hardware (unterschiedliche ellipsometrische Funktionsprinzipien) als auch die ellipsometrische Software (Modell-Randbedingungen, Fitalgorithmus) firmenspezifisch zum Teil sehr unterschiedlich sind. Hierbei mussten in einem Konsensprozess Lösungen gefunden werden, die die beiden deutschen Ellipsometer-Anbieter Accurion (Imaging-Ellipsometrie) und SENTECH Instruments (Mapping Ellipsometrie) gleichermaßen akzeptieren konnten und die zudem einen Transfer auf die Internationale Ebene (ISO Norm) ermöglichen, also vom Grundsatz her auch auf weitere Ellipsometerhersteller wie (J. A. Woollam Co., USA; SEMILAB, Ungarn; HORIBA, Japan) mit wieder anderen ellipsometrischen Funktionsprinzipien, Hard- und Softwarelösungen anwendbar sind. Die weitgehende Unabhängigkeit von ellipsometrischen Funktionsprinzipien, Hard- und Softwarelösungen wurde dadurch erreicht, dass normativ festgelegt wurde, dass die ellipsometrischen Größen PSI und DELTA im Sinne von DIN ENISO/IEC 17025 als Rohdaten fungieren. KW - Ellipsometrie-Norm KW - Messunsicherheit ellipsometrischer Messungen KW - Validierungskonzepte ellipsometrischer Messungen KW - DIN 50989, Teile 1 bis 6 KW - DIN EN ISO/IEC 17025:2018 und GUM Kompatibilität PY - 2021 SP - 1 EP - 16 AN - OPUS4-52857 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe A1 - Fischer, Daniel T1 - MISTRAL-Müller-Matrix-basierte Identifizierung von Inhomogenitäten und strukturellen Anomalien N2 - Mit abbildender Ellipsometrie (imaging ellipsometry: IE) können Nanometer-Beschichtungen/ Degradationen visualisiert und bezüglich Brechungsindex n, Extinktionskoeffizient k und Schichtdicke d charakterisiert werden. Materialseitig werden lokal Homogenität und Isotropie innerhalb eines/mehrerer Bildpunkte (field of analysis: FOA) und messtechnisch global die Ebenheit der Proben bezüglich aller Bildpunkte des Messfeldes vorausgesetzt. Für die Müller-Matrix-basierte abbildende Ellipsometrie (MM-IE), die den optischen Response anisotroper Materialien in jedem Bildpunkt über die bis zu 16 Müller-Matrix-Elemente erfasst, ist dies von besonderer Relevanz. Reale Substrate sind aber oft nicht eben, können lokal Noppen/Mulden (im FOA) aufweisen oder sind global konvex/ konkav im möglichen Messfeld (field of view: FOV) gekrümmt. Diese lokalen/globalen strukturellen Anomalien des Substrats werden schon für die IE messtechnisch/modellseitig oft nicht beherrscht und sind für die MM-IE in der Wirkung auf die MM-Elemente unbekannt. Diese Defizite sollen messtechnisch bzw. modellmäßig behoben und somit die Messung lokal/global gekrümmter Oberflächen ermöglicht werden (MM-CSIE, CS curved surface). KW - Abbildende Ellipsometrie (IE) KW - Müller-Matrix Ellipsometrie (MM-IE) KW - Gekrümmte Oberflächen KW - Schichtdicke KW - Optische Konstanten PY - 2020 SP - 1 EP - 7 AN - OPUS4-51574 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe A1 - Hielscher-Hofinger, Stefan A1 - Lerche, D. A1 - Reetz, U. T1 - Vorhaben ZENSUS, BAM Vh-Nr. 6768 „Zentrifugentechnologie zur statistischen Untersuchung von Stumpfklebungen“ N2 - Das Vorhaben ZENSUS beschäftigt sich mit der Erstellung eines Normenentwurfs bzw. einer normen-konformen Technischen Spezifikation für die Zentrifugen-basierte Prüfung der Klebfestigkeit von Stumpfklebungen. Das umfasst auch umfangreiche Validierungsversuche, um mögliche Unterschiede zwischen Kraft-gesteuerter (Zentrifuge) und Weg-gesteuerter (Zugprüfmaschine) bzw. ggf. dazu korrelierte Materialabhängigkeiten mit ihren Auswirkungen auf SOPs zu identifizieren. Die Zentri-fugen-basierte Mehr-Proben-Prüfung von bis zu 8 Klebverbunden wird im Weiteren mit CAT-Technologie („Centrifugal Adhesion Testing“) abgekürzt. KW - Klebfestigkeit von Stumpfklebungen KW - EN 15870 KW - Centrifugal Adhesion Testing (CAT) Technologie KW - Zugprüfung mittels Zugprüfmaschine KW - Zugprüfung mittels Zentrifugentechnologie PY - 2021 SP - 1 EP - 28 AN - OPUS4-52858 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Altmann, Korinna A1 - Sommerfeld, Thomas A1 - Braun, Ulrike T1 - Quantification of microplastics in a freshwater suspended organic matter using different thermoanalytical methods – outcome of an interlaboratory comparison N2 - A sedimented freshwater suspended organic matter fortified with particles of polyethylene (PE), polypropylene (PP), polystyrene (PS), and polyethylene terephthalate (PET) was employed in an interlaboratory comparison of thermoanalytical methods for microplastics identification and quantification. Three laboratories performed pyrolysis gas chromatography-mass spectrometry (Py-GC-MS), three others provided results using thermal extraction desorption followed by gas chromatography coupled to mass spectrometry (TED-GC-MS). One participant performed thermogravimetry-infrared spectroscopy (TGA-FTIR) and two participants used thermogravimetry coupled to mass spectrometry (TGA-MS). Further participants used differential scanning microscopy (DSC), a procedure based on micro combustion calorimetry (MCC) and a procedure based on elemental analysis. Each participant employed a different combination of sample treatment, calibration and instrumental Settings for polymer identification and quantification. Though there is obviously room for improvements regarding the between-laboratory reproducibility and the harmonization of procedures it was seen that the participants Performing Py-GC-MS, TED-GC-MS, and TGA-FTIR were able to correctly identify all polymers and to report reasonable quantification results in the investigated concentration range (PE: 20.0 μg/mg, PP: 5.70 μg/mg; PS: 2.20 μg/mg, PET: 18.0 μg/mg). Although for the other methods limitations exists regarding the detection of specific polymers, they showed potential as alternative approaches for polymer quantification in solid environmental matrices. KW - Interlaboratory comparison KW - Microplastics KW - Suspended organic matter KW - Pyrolysis PY - 2020 DO - https://doi.org/10.1016/j.jaap.2020.104829 VL - 148 SP - 1 EP - 6 PB - Elsevier B.V. AN - OPUS4-50977 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Scholz, Philipp A1 - Jung, Christian A1 - Weidner, Steffen T1 - Thermo-Desorption Gas Chromatography-Mass Spectrometry for investigating the thermal degradation of polyurethanes N2 - Thermo-Desorption Gas Chromatography-Mass Spectrometry (TD-GC-MS) was used to investigate the thermal degradation of two different polyurethanes (PU). PU samples were heated at different heating rates and the desorbed products were collected in a cold injection system and thereafter submitted to GC-MS. Prospects and limitations of the detection and quantification of semi-volatile degradation products were investigated. A temperature dependent PU depolymerization was found at temperatures above 200 °C proved by an increasing release of 1,4-butanediol and methylene diphenyl diisocyanate (MDI) representing the main building blocks of both polymers. Their release was monitored quantitatively based on external calibration with authentic compounds. Size Exclusion Chromatography (SEC) of the residues obtained after thermodesorption confirmed the initial competitive degradation mechanism indicating an equilibrium of crosslinking and depolymerization as previously suggested. Matrix-Assisted Laser Desorption Ionization (MALDI) mass spectrometry of SEC fractions of thermally degraded PUs provided additional hints on degradation mechanism. KW - Thermo-desorption KW - Mass spectrometry KW - Polyurethanes KW - Thermal degradation PY - 2023 DO - https://doi.org/10.1039/D3AY00173C SN - 1759-9660 SP - 1 EP - 6 PB - Royal Society for Chemistry AN - OPUS4-57307 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bekemeier, Simon A1 - Caldeira Rêgo, C. R. A1 - Mai, H. L. A1 - Sikia, Ujjal A1 - Waseda, O. A1 - Apel, M. A1 - Arendt, F. A1 - Aschemann, A. A1 - Bayerlein, Bernd A1 - Courant, R. A1 - Dziwis, G. A1 - Fuchs, F. A1 - Giese, U. A1 - Junghanns, K. A1 - Kamal, M. A1 - Koschmieder, L. A1 - Leineweber, S. A1 - Luger, M. A1 - Lukas, M. A1 - Maas, J. A1 - Mertens, J. A1 - Mieller, Björn A1 - Overmeyer, L. A1 - Pirch, N. A1 - Reimann, J. A1 - Schröck, S. A1 - Schulze, P. A1 - Schuster, J. A1 - Seidel, A. A1 - Shchyglo, O. A1 - Sierka, M. A1 - Silze, F. A1 - Stier, S. A1 - Tegeler, M. A1 - Unger, Jörg F. A1 - Weber, M. A1 - Hickel, Tilmann A1 - Schaarschmidt, J. T1 - Advancing Digital Transformation in Material Science: The Role of Workflows Within the MaterialDigital Initiative N2 - The MaterialDigital initiative represents a major driver toward the digitalization of material science. Next to providing a prototypical infrastructure required for building a shared data space and working on semantic interoperability of data, a core focus area of the Platform MaterialDigital (PMD) is the utilization of workflows to encapsulate data processing and simulation steps in accordance with findable, accessible, interoperable, and reusable principles. In collaboration with the funded projects of the initiative, the workflow working group strives to establish shared standards, enhancing the interoperability and reusability of scientific data processing steps. Central to this effort is the Workflow Store, a pivotal tool for disseminating workflows with the community, facilitating the exchange and replication of scientific methodologies. This article discusses the inherent challenges of adapting workflow concepts, providing the perspective on developing and using workflows in the respective domain of the various funded projects. Additionally, it introduces the Workflow Store’s role within the initiative and outlines a future roadmap for the PMD workflow group, aiming to further refine and expand the role of scientific workflows as a means to advance digital transformation and foster collaborative research within material science. KW - Digitalisation KW - FAIR principles KW - MaterialDigital KW - Scientific workflows KW - Semantic interoperability PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-624088 DO - https://doi.org/10.1002/adem.202402149 SN - 1527-2648 IS - 2402149 SP - 1 EP - 25 PB - Wiley-VCH GmbH AN - OPUS4-62408 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Belenguer, A A1 - Michalchuk, Adam A1 - Lampronti, G A1 - Sanders, J T1 - Using solid catalysts in disulfide-based dynamic combinatorial solution- and mechano-chemistry N2 - We here show for the first time that solid amines can act as catalysts for disulfide-based dynamic combinatorial chemistry by ball mill grinding. The mechanochemical Equilibrium for the two disulfide reactions studied is reached within one to three hours using ten different amine catalysts. This contrasts with the weeks to months to achieve solution equilibrium for most solid amine catalysts at 2%M at 2mM concentration in a suitable solvent. The final mechanochemical equilibrium is independent of the catalyst used, but varies with other ball mill grinding factors such as the presence of traces of solvent. The different efficiencies of the amines tested are discussed. KW - Mechanochemistry KW - Green chemistry KW - Catalysis PY - 2022 DO - https://doi.org/10.1002/cssc.202102416 SN - 1864-5631 VL - 15 IS - 3 SP - 1 EP - 10 PB - Wiley AN - OPUS4-53930 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Belenguer, A. A1 - Lampronti, G. A1 - Michalchuk, Adam A1 - Emmerling, Franziska A1 - Sanders, J. T1 - Quantitative reversible one pot interconversion of three crystalline polymorphs by ball mill grinding N2 - We demonstrate here using a disulfide system the first example of reversible, selective, and quantitative transformation between three crystalline polymorphs by ball mill grinding. This includes the discovery of a previously unknown polymorph. Each polymorph is reproducibly obtained under well-defined neat or liquid-assisted grinding conditions, revealing subtle control over the apparent thermodynamic stability. We discovered that the presence of a contaminant as low as 1.5% mol mol−1 acting as a template is required to enable all these three polymorph transformations. The relative stabilities of the polymorphs are determined by the sizes of the nanocrystals produced under different conditions and by surface interactions with small amounts of added solvent. For the first time, we show evidence that each of the three polymorphs is obtained with a unique and reproducible crystalline size. This mechanochemical approach gives access to bulk quantities of metastable polymorphs that are inaccessible through recrystallisation. KW - Mechanochemistry KW - Polymorph KW - XRD PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549934 DO - https://doi.org/10.1039/D2CE00393G SP - 1 EP - 7 PB - Royal Society of Chemistry AN - OPUS4-54993 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Benner, Philipp A1 - Grandel, Jonas T1 - A shortcut towards phonon predictions N2 - Phonon calculations with ab-initio methods are computationally expensive. The use of universal machine learning models reduces the cost, but raises concerns about prediction quality. Fine-tuning with only a few structures, improves predictions of phonons, thermal properties and especially diffusive thermal conductivity, while reducing computational cost by a factor of 10 in average compared to DFT methods. T2 - DPG Frühjahrstagung CY - Regensburg, Germany DA - 16.03.2025 KW - Machine Learning KW - MACE KW - Phonons PY - 2025 AN - OPUS4-62770 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bennet, Francesca T1 - Towards a method for quantitative evaluation of nanoparticles in suspension via Microprinting and SEM analysis N2 - A series of different nanoparticle suspensions (Gold, Latex, and SiO2 in varying concentrations) were microprinted onto TEM grids in a 4 x 4 array in the concentration range 7x10^8 to 1x10^11 NP/mL and imaged with SEM and TSEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee ring effect. T2 - nanoSAFE 2020 CY - Online meeting DA - 16.11.2020 KW - Nanoparticles KW - Microprinting KW - Image analysis PY - 2020 AN - OPUS4-51699 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bennet, Francesca T1 - Microprinting and SEM analysis for quantitative evaluation of nanoparticles in solution N2 - Nanoparticle suspensions were microprinted onto TEM grids for subsequent analysis by SEM/TSEM and evaluation of particle numbers using Image J software. Various nanoparticle types, concentrations and printing conditions (temperature, rel. humidity) were evaluated in order to determine the optimal conditions for producing a uniform distribution of particles on the substrate and eliminating the coffee ring effect. T2 - H2020 ACEnano Project Meeting CY - Amsterdam, Netherlands DA - 04.03.2020 KW - Nanoparticle KW - Imaging KW - Microprinting KW - Homogeneous deposition PY - 2020 AN - OPUS4-50584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bennet, Francesca A1 - Burr, L. A1 - Schmid, D. A1 - Hodoroaba, Vasile-Dan T1 - Towards a method for quantitative evaluation of nanoparticle from suspensions via microarray printing and SEM analysis N2 - As part of the development of a library of accurate and efficient methods for measurement of nanoparticle properties, we develop and optimize a method for the efficient analysis of nanoparticle size distribution from suspensions via microprinting and digital analysis of electron microscopy (SEM and TEM) images, with the ultimate aim of automated quantitative concentration analysis (calculated from drop volume). A series of different nanoparticle suspensions (gold, latex, and SiO2 in varying sizes and concentrations) were printed onto TEM grids in a 4 x 4 array in the concentration range 7x10^8 to 1x10^11 nanoparticles/mL and imaged with SEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee-ring effect. KW - Nanoparticles KW - Particle size distribution KW - Electron microscopy KW - Microarray printing KW - Sample preparation KW - Nanoparticle concentration PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-528455 DO - https://doi.org/10.1088/1742-6596/1953/1/012002 VL - 1953 SP - 012002 PB - IOP Publishing AN - OPUS4-52845 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bennet, Francesca A1 - Hodoroaba, Vasile-Dan T1 - BAM reference data - SEM raw data for the particles size distribution of Al-coated titania nanoparticles (JRCNM62001a and JRCNM62002a) N2 - SEM raw images of Al-coated titania nanoparticles (JRCNM62001 and JRCNM62002a) provided by the JRC repository are provided together with the particle size distribution of the minimum Feret Diameter extracted from the given images. KW - SEM KW - Titania nanoparticles KW - Particle size distribution KW - BAM reference data PY - 2021 DO - https://doi.org/10.5281/zenodo.5007367 PB - Zenodo CY - Geneva AN - OPUS4-52836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -