TY - JOUR A1 - Gehrenkemper, Lennart A1 - Simon, Fabian A1 - Roesch, Philipp A1 - Fischer, E. A1 - von der Au, Marcus A1 - Pfeifer, Jens A1 - Cossmer, Antje A1 - Wittwer, Philipp A1 - Vogel, Christian A1 - Simon, Franz-Georg A1 - Meermann, Björn T1 - Determination of organically bound fluorine sum parameters in river water samples - Comparison of combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) N2 - In this study, we compare combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) with respect to their applicability for determining organically Bound fluorine sum parameters. Extractable (EOF) and adsorbable (AOF) organically bound fluorine as well as total fluorine (TF) were measured in samples fromriver Spree in Berlin, Germany, to reveal the advantages and disadvantages of the two techniques used as well as the two established fluorine sum Parameters AOF and EOF. TF concentrations determined via HR-CS-GFMAS and CIC were comparable between 148 and 270 μg/L. On average, AOF concentrations were higher than EOF concentrations, with AOF making up 0.14–0.81% of TF (determined using CIC) and EOF 0.04–0.28% of TF (determined using HR-CSGFMAS). The results obtained by the two independent methods were in good agreement. It turned out that HR-CS-GFMAS is a more sensitive and precise method for fluorine analysis compared to CIC. EOF and AOF are comparable tools in Risk evaluation for the emerging pollutants per- and polyfluorinated alkyl substances; however, EOF is much faster to conduct. KW - High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) KW - Combustion ion chromatography (CIC) KW - Per- and polyfluorinated alkyl substances (PFASs) KW - Adsorbable organically bound fluorine (AOF) KW - Extractable organically bound fluorine (EOF) KW - Surface waters PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-515351 SN - 1618-2650 VL - 413 IS - 28 SP - 103 EP - 115 PB - Springer CY - Berlin AN - OPUS4-51535 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp T1 - Summenparameter in der PFAS-Analytik - CIC & HR-GFMAS Methodenvergleich N2 - Gastvortrag auf der 43. Sitzung des Fachbeirates Bodenuntersuchungen über Summenparameter in der PFAS-Analytik und den CIC & HR-GFMAS Methodenvergleich. T2 - 43. Sitzung des Fachbeirates Bodenuntersuchungen CY - Online meeting DA - 18.02.2021 KW - PFAS KW - Analytik KW - CIC KW - HR-GF-MAS KW - Summenparameter PY - 2021 AN - OPUS4-52148 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Wittwer, Philipp T1 - Current challenges on PFAS analytics N2 - Several thousand PFAS are in circulation and the current challenge lies in detection of these compounds. Wheter environmental contamination occurs via industrial emission or direct PFAS exposure, as through the use of AFFF fire fighting foams. Wheter PFAS need to be detected in consumer products or agricultral soil, or wheter human and wildlife exposure to PFSA needs to be evaluated, suitable analytical methods are required to identifiy the target class within a hugh variety of matrices. At the same time it is critical to detect trace amounts of compounds within various matrices, we want to make sure that we consider very volatile and mobile species, simultaneously want to assure that we do not overlook less and insoluble compounds. We require methods that allow both single and multi target analysis and want to have an ideal overview with the help of sum parameters. T2 - Workshop - Advancements of Analytical Techniques for Per- and Polyfluoroalkyl Substances (PFAS) CY - Online meeting DA - 01.09.2021 KW - PFAS KW - PFAS analytics KW - EOF/AOF PY - 2021 AN - OPUS4-53196 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Vogel, Christian T1 - micro-XRF und XANES-Analytik von PFAS N2 - Ergebnispräsentation über gesammelte Ergebnisse der Synchrotron F µ-XRF und -XANES Spektroskopischen Untersuchungen von PFAS und PFAS-haltigen Materialien T2 - Online-Seminar des Fortbildungsverbundes Boden und Altlasten Baden-Württemberg CY - Online meeting DA - 07.12.23 KW - PFAS KW - XANES KW - XRF KW - Röntgenspektroskopie KW - Synchrotron PY - 2023 AN - OPUS4-59077 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Wittwer, Philipp A1 - Vogel, Christian A1 - Simon, Franz-Georg T1 - Investigation of PFAS Contaminated Solid Matrices by Combustion Ion Chromatography (CIC) - Development of EOF and AOF as Sum Parameters in Environmental Analysis N2 - Per- and polyfluoralkyl surfactants (PFAS) are industrially produced surface chemicals used in daily applications that have gained public and political attention due their unnaturally high appearance in drinking water, nourishments and soils.[1] Their chemical structures exhibit both lipophilic and hydrophilic properties, leading to a highly inert and persistent character.[2] Various PFAS have shown to be bioaccumulative in plants and animals, and some have been characterized as highly toxic when ingested.[3] When exposed to the environment, PFAS slowly get mobilized by natural water resources, leading to contamination of large areas of soil and natural water sources.[4] While PFAS contamination of drinking water has been investigated intensively, perfluoralkyl contamination of soils has been rarely examined as of yet. At the same time, an increasing amount of PFAS contamination sites are being discovered worldwide, calling for a sophisticated strategy towards analytical characterization.[5] Since the number of known PFAS already exceeds 4700, the established sum parameters like extractable organic fluorine (EOF) and adsorbable organic fluorine (AOF) are key elements to fully survey the impact of exposure.[6] Simultaneously, innovative soil remediation strategies are required to contain environmental destruction and to minimize further spreading of contaminants.[7] Addressing these challenges requires suitable analytical devices that are capable of mobilizing PFAS in the solid as well as in the liquid phase. The use of combustion ion chromatography (CIC) enables analysis of both immobile and volatile PFAS and allows the detection of both total fluorine (TF) and EOF or AOF of a given soil or aqueous sample. Based on preliminary results, the clean-up of a PFAS contaminated matrix is monitored via EOF detection over time. Additionally, we tested the effectiveness of urea (CH₄N₂O) as fluoride scavenger with the aim to improve the separation of inorganic and organic fluorine and therefore, to improve AOF accuracy. The presented findings can be contributive with regard to future AOF/EOF sum parameter development and application. T2 - Eurosoil 2021 CY - Online meeting DA - 23.08.2021 KW - PFAS KW - Sum parameter analyis KW - Combustion ion chromatography PY - 2021 AN - OPUS4-53195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Vogel, Christian A1 - Simon, Franz-Georg T1 - 8. Netzwerktreffen PerFluSan N2 - Vorstellung der Projektarbeit der BAM auf dem 8. Netzwerktreffen PerFluSan in Dresden T2 - 8. Netzwerktreffen PerFluSan CY - Fraunhofer IKTS, Dresden, Germany DA - 09.03.2020 KW - PFC KW - Sanierung KW - Kontamination KW - Boden PY - 2020 AN - OPUS4-50552 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Wittwer, Philipp A1 - Simon, Franz-Georg T1 - Detailed Investigation of Perfluoroalkyl Surfactant Contaminated Soil Samples by Combustion Ion Chromatography - Development of EOF and AOF as Reference Values in Environmental Analysis N2 - Per- and polyfluoralkyl surfactants (PFASs) are industrially produced surface chemicals used in daily applications that have gained public and political attention due their unnaturally high appearance in drinking water, nourishments and soils. Their chemical structures exhibit both lipophilic and hydrophilic properties, leading to a highly inert and persistent character. Various PFASs have shown to be bioaccumulative in plants and animals, and some have been characterized as highly toxic when ingested. When exposed to the environment, PFASs slowly get mobilized by natural water resources, leading to contamination of large areas of soil and natural water sources. While PFASs contamination of drinking water has been investigated intensively, perfluoralkyl contamination of soils has been rarely examined as of yet. At the same time, an increasing amount of PFASs contamination sites are being discovered worldwide, calling for a sophisticated strategy towards analytical characterization. Since the number of known PFASs already exceeds 4700, the established sum parameters like extractable organic fluorine (EOF) and adsorbable organic fluorine (AOF) are key elements to fully survey the impact of exposure. Simultaneously, innovative soil remediation strategies are required to contain environmental destruction and to minimize further spreading of contaminants. Addressing these challenges requires suitable analytical devices that are capable of mobilizing PFASs in the solid as well as in the liquid phase. The use of combustion ion chromatography (CIC) enables analysis of both immobile and volatile PFASs and allows the detection of both total fluorine (TF) and EOF or AOF of a given soil or aqueous sample. Based on preliminary results, the clean-up of a PFAS contaminated solid matrix is monitored via EOF detection over time. Additionally, we demonstrate the pH dependency of hydrogen fluoride absorption on active carbon (AC) and found a simple organic additive to be an effective fluoride scavenger. The presented findings can be contributive with regard to future AOF/EOF sum parameter development and application. T2 - DECHEMA Symposium Strategien zur Boden- und Grundwassersanierung 2020 CY - Online meeting DA - 23.11.2020 KW - PFAS KW - SPE extraction KW - Combustion ion chromatography KW - Organo fluorine analysis KW - Soil extraction KW - Sewage extraction PY - 2020 AN - OPUS4-51978 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Witter, Philipp A1 - Vogel, Christian A1 - Kalbe, Ute A1 - Simon, Franz-Georg T1 - How to investigate potential emission sources of PFAS in consumer product materials? Comparative extraction approaches and sum parameter analysis by combustion ion chromatography (CIC) N2 - Besides classical per- and polyfluorinated alkylated substances (PFAS), side-chain fluorinated polymers (SFPs) are widely applied as efficient anti-wetting and anti-greasing coatings in various daily applicated consumer products such as outdoor apparel, carpetry or paper-based food contact materials. Although the fluorinated sidechains are chemically bound to a base polymer, their release can be triggered by environmental influences or wear-off, thus contribute as significant sources of PFAS in the environment. Since only little knowledge of PFAS and SFP composition in consumer products is available, a comprehensive analytical approach might be beneficial. T2 - SETAC Konferenz 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - PFAS KW - Combustion Ion Chromatography KW - Comsumer good samples PY - 2023 AN - OPUS4-57422 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Vogel, Christian A1 - Wittwer, Philipp A1 - Simon, Franz-Georg T1 - Analysis of PFAS in Environmental Samples and Materials - Different Approaches via Fluorine K-Edge XANES Spectroscopy and Combustion Ion Chromatography N2 - Per- and polyfluoroalkyl substances (PFAS) have emerged over the course of the last twenty years as a global pollution issue. Altogether, there are currently more than 4700 known but only partly characterized fluorinated compounds identified by the Organization for Economic Cooperation and Development (OECD), as shown by a recently published classification proposal. The ongoing production of new, yet unrestricted PFAS alternatives has become a major challenge for environmental routine analytics, since the state-of-the-art method LC-MS/MS relies on structural information and availability of isotope standards of the targeted compound. First reported by Miyake et al., fluorine sum parameters like adsorbable organic fluorine (AOF), extractable organic fluorine (EOF) and total fluorine (TF) can be applied to survey and detect the presence of large amounts of unidentified organofluorine compounds in environmental matrices. Today fluorine sum parameters have been established as a useful supplement to classic target-analytical approaches of PFAS and were implemented for the first time as a sum value “PFAS-total” in the recently revised Drinking Water Directive (2020/2184) by the European Commission. In contrast, X-ray absorption near-edge structure (XANES) spectroscopy has been widely applied to identify low concentration of element-specific contamination without pre-treatment in environmental samples in the past. The XANES approach enables a penetration depth of approx. 1 µm (at fluorine K-edge energy; depending on the matrix) which is significantly deeper than for X-ray photoelectron spectroscopy (XPS; penetration depth approx. 10 nm). Furthermore, the method is fast, non-destructive and only simple preparation of the samples is required. In our work, we combined both F-XANES spectroscopy and combustion ion chromatography (CIC) in order to present a new analytical perspective on the investigation of PFAS in environmental media and material samples. T2 - SETAC Europe 2022 - 32nd Annual Meeting CY - Kopenhagen, Dänemark DA - 15.05.2022 KW - Sum parameter analysis KW - EOF KW - CIC KW - Fluor XANES KW - PFAS analysis PY - 2022 AN - OPUS4-54884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Roesch, Philipp A1 - Schinnen, Andrea A1 - Riedel, Maren A1 - Sommerfeld, Thomas A1 - Sawal, G. A1 - Bandow, N. A1 - Vogel, Christian A1 - Kalbe, Ute A1 - Simon, Franz-Georg T1 - Investigation of pH-dependent extraction methods for PFAS in (fluoropolymer-based) consumer products: A comparative study between targeted and sum parameter analysis N2 - Here, we report a comparative study of different sum parameter analysis methods for the extraction of per- and polyfluoroalkyl substances (PFAS) from manufactured consumer products, which can be measured by combustion ion chromatography (CIC). Therefore, a hydrolysis-based extraction method was further developed, which accounts for the addition of hydrolyzable covalently bound polyfluoroalkylated side-chain polymers (SFPs) to the extractable organic fluorine portion of the mass balance proposed as "hydrolyzable organically bound fluorine" (HOF). To test this hypothesis, the method was applied to 39 different consumer products containing fluoropolymers or monomeric PFAS taken from four different categories: outdoor textiles, paper packaging, carpeting, and permanent baking sheets. We also evaluated the method's efficiency by extracting four synthesized fluorotelomer polyacrylate reference compounds. The total fluorine (TF) and extractable organically bound fluorine (EOF) values were measured through CIC using established protocols. The TF values ranged from sub-ppb to %-levels, depending on the compound class. All samples showed results for hydrolyzed organofluorine (HOF) between 0.03 and 76.3 μg/g, while most EOF values were lower (C8 (e.g. 580 µg/kg dw PFOS for Soil1), whereas the consumer product samples showed a more uniform distribution with regard to chain lengths from C4 to C8. Independent from quantified PFAS amounts via target analysis, µ-XRF mapping combined with µ-XANES spectroscopy was successfully applied to detect both point-specific concentration maxima and evenly distributed surface coatings of fluorinated organic contaminants in the corresponding samples. KW - PFAS KW - XRF KW - LC-MS/MS KW - XANES KW - Fluoride KW - Soil PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-576109 SN - 2050-7887 SP - 1 EP - 12 PB - Royal Society of Chemistry AN - OPUS4-57610 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp A1 - Wittwer, Philipp A1 - Simon, Franz-Georg T1 - CIC & HR-GFMAS: Über Summenparameter in der PFAS-Analytik - Entwicklung von AOF-Parametern anhand Combustion Ion Chromatography N2 - Kurzzsammenfassung der bisherigen Ergebnisse der Vorhaben 4320 und 4390 beim Netzwerktreffen des PerFluSan Netzwerks T2 - Netzwerktreffen PerFluSan CY - Online meeting DA - 19.11.2020 KW - PFAS KW - PFC KW - AOF KW - EOF PY - 2020 AN - OPUS4-51625 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ruyle, B. A1 - Pickard, H. A1 - Schultes, L. A1 - Fredriksson, F. A1 - Heffernan, A. A1 - Knappe, D. A1 - Lord, H. A1 - Meng, P. A1 - Mills, M. A1 - Ndungu, K. A1 - Roesch, Philipp A1 - Rundberget, J.T. A1 - Tettenhorst, D. A1 - Van Buren, J. A1 - Vogel, Christian A1 - Westerman, D. A1 - Yeung, L. A1 - Sunderland, E. T1 - Interlaboratory Comparison of Extractable Organofluorine Measurements in Groundwater and Eel (Anguilla rostrata): Recommendations for Methods Standardization N2 - Research on per- and polyfluoroalkyl substances (PFAS) frequently incorporates organofluorine measurements, particularly because they could support a class-based approach to regulation. However, standardized methods for organofluorine analysis in a broad suite of matrices are currently unavailable, including a method for extractable organofluorine (EOF) measured using combustion ion chromatography (CIC). Here, we report the results of an international interlaboratory comparison. Seven laboratories representing academia, government, and the private sector measured paired EOF and PFAS concentrations in groundwater and eel (Anguilla rostrata) from a site contaminated by aqueous film-forming foam. Among all laboratories, targeted PFAS could not explain all EOF in groundwater but accounted for most EOF in eel. EOF results from all laboratories for at least one replicate extract fell within one standard deviation of the interlaboratory mean for groundwater and five out of seven laboratories for eel. PFAS spike mixture recoveries for EOF measurements in groundwater and eel were close to the criterion (±30%) for standardized targeted PFAS methods. Instrumental operation of the CIC such as replicate sample injections was a major source of measurement uncertainty. Blank contamination and incomplete inorganic fluorine removal may introduce additional uncertainties. To elucidate the presence of unknown organofluorine using paired EOF and PFAS measurements, we recommend that analysts carefully consider confounding methodological uncertainties such as differences in precision between measurements, data processing steps such as blank subtraction and replicate analyses, and the relative recoveries of PFAS and other fluorine compounds. KW - Extractable organic fluorine KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Combustion ion chromatography (CIC) PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-587726 SN - 0013-936X VL - 57 IS - 48 SP - 20159 EP - 20168 PB - American Chemical Society (ACS) AN - OPUS4-58772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Simon, Fabian A1 - Gehrenkemper, Lennart A1 - von der Au, Marcus A1 - Wittwer, Phillip A1 - Roesch, Philipp A1 - Pfeifer, Jens A1 - Cossmer, Antje A1 - Meermann, Björn T1 - A fast and simple PFAS extraction method utilizing HR–CS–GFMAS for soil samples N2 - Here, we describe an optimized fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) in soils utilizing high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS). To omit the bias of the solid phase extraction (SPE) step commonly used during the analysis of extractable organically bound fluorine (EOF) we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol without any additional SPE. Four extraction steps were representative to determine a high proportion of the EOF (>80% of eight extractions). Comparison of the optimized method with and without an additional SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. Differences of up to 94% were observed which were not explainable by coextracted inorganic fluoride. Therefore, not only a more accurate but also a more economic as well as ecologic method (bypassing of unnecessary SPE) was developed. The procedural limit of quantification (LOQ) of the developed method was 10.30 μg/kg which was sufficient for quantifying EOF concentrations in all tested samples. For future PFAS monitoring and potential regulative decisions the herein presented optimized extraction method can offer a valuable contribution. KW - Per- and polyfluorinated alkly substances (PFASs) KW - High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) KW - Soils KW - Solid phase extraction (SPE) KW - Extractable organically bound fluorine (EOF) KW - Solid-liquid extraction PY - 2022 U6 - https://doi.org/10.1016/j.chemosphere.2022.133922 VL - 295 SP - 1 EP - 9 PB - Elsevier Ltd. AN - OPUS4-54359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogel, Christian A1 - Roesch, Philipp A1 - Wittwer, Philipp A1 - Piechotta, Christian A1 - Lisec, Jan A1 - Sommerfeld, Thomas A1 - Kluge, Stephanie A1 - Herzel, Hannes A1 - Huthwelker, T. A1 - Borca, C. A1 - Simon, Franz-Georg T1 - Levels of per- and polyfluoroalkyl substances (PFAS) in various wastewater-derived fertilizers – analytical investigations from different perspectives N2 - Solid wastewater-based fertilizers were screened for per- and polyfluoroalkyl substances (PFAS) by the extractable organic fluorine (EOF) sum parameter method. The EOF values for ten sewage sludges from Germany and Switzerland range from 154 to 7209 mg kg−1. For thermal treated sewage sludge and struvite the EOF were lower with values up to 121 mg kg−1. Moreover, the application of PFAS targeted and suspect screening analysis of selected sewage sludge samples showed that only a small part of the EOF sum parameter values can be explained by the usually screened legacy PFAS. The hitherto unknown part of EOF sum parameter contains also fluorinated pesticides, pharmaceutical and aromatic compounds. Because these partly fluorinated compounds can degrade to (ultra-)short PFAS in wastewater treatment plants they should be considered as significant sources of organic fluorine in the environment. The combined results of sum parameter analysis and suspect screening reveal the need to update current regulations, such as the German fertilizer ordinance, to focus not solely on a few selected PFAS such as perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) but consider an additional sum parameter approach as a more holistic alternative. Moreover, diffusion gradient in thin-films (DGT) passive samplers were utilized as an alternative simplified extraction method for PFAS in solid wastewater-based fertilizers and subsequently quantified via combustion ion chromatography. However, the DGT method was less sensitive and only comparable to the EOF values of the fertilizers in samples with >150 mg kg−1, because of different diffusion properties for various PFAS, but also kinetic exchange limitations. KW - Combustion Ion Chromatography KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Sewage sludge KW - Fertilizer PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-583429 VL - 2 IS - 10 SP - 1436 EP - 1445 PB - Royal Society of Chemistry (RSC) AN - OPUS4-58342 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Vogel, Christian A1 - Roesch, Philipp A1 - Wittwer, Philipp A1 - Simon, Franz-Georg ED - Holm, O. ED - Thomé-Kozmiensky, E. ED - Quicker, P. ED - Kopp-Assenmacher, S. T1 - Per- und polyfluorierte Alkylsubstanzen (PFAS) im Klärschlamm N2 - Per- and polyfluoroalkyl substances (PFAS) are a group of more than 4700 anionic and cationic anthrophonic substances which have been used extensively in a variety of products and industries due to their inert chemical stability and resistance to degradation by heat or acids. As a result of continuous use, mainly in aviation firefighting foams, thousands of industrial and military installations have been found to contain contaminated soil and groundwater resources. However, because of the continuous use of fluorinated consumer products, also effluents and sewage sludge from wastewater treatment plants (WWTPs) have been shown to be an important source of PFAS contamination into the aquatic environment. Resulting from recent stricter regulations and restrictions in the last years on the use of long chain (≥C8) PFAS, there is a significant shift in the chemical industry towards production of short (C4-C7) and ultrashort (C1-C3) chain alternatives. With the amendment of the Sewage Sludge Ordinance in 2017 the German legislation banned sewage sludge application on agricultural land, and by 2029/2032 sewage sludge will be completely prohibited from agricultural application. While environmental exposure of organic pollutants like PFAS, pesticides and pharmaceuticals are no longer desirable, phosphorus (P) from sewage sludge must still be used to produce high-quality P-fertilizers for a circular economy. Currently, plant-available P-fertilizers from sewage sludge/wastewater can be produced using a variety of treatment approaches including precipitation, leaching, and thermal treatment. However, the fate of legacy and emerging PFAS compounds during P leaching, precipitation and treatment from sewage sludge and wastewater is for the most parts still unknown. KW - Combustion Ion Chromatography KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Klärschlamm KW - Düngemittel PY - 2022 SN - 978-3-944310-65-7 SP - 270 EP - 279 PB - Thomé-Kozmiensky Verlag GmbH CY - Neuruppin AN - OPUS4-56290 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zweigle, J. A1 - Capitain, C. A1 - Simon, Fabian Michael A1 - Roesch, Philipp A1 - Bugsel, B. A1 - Zwiener, C. T1 - Non-extractable PFAS in functional textiles − Characterization by complementary methods: oxidation, hydrolysis, and fluorine sum parameters N2 - Per- and polyfluoroalkyl substances (PFAS) are widely used for durable water-repellent finishing of different fabrics and textiles like outdoor clothing, carpets, medical textiles and more. Existing PFAS extraction techniques followed by target analysis are often insufficient in detecting widely used side-chain fluorinated polymers (SFPs) that are barely or non-extractable. SFPs are typically copolymers consisting of a non-fluorinated backbone with perfluoroalkyl side-chains to obtain desired properties. We compared the accessible analytical information and performance of complementary techniques based on oxidation (dTOP assay, PhotoTOP), hydrolysis (THP assay), standard extraction, extractable organic fluorine (EOF), and total fluorine (TF) with five functional textiles and characterized 7 further textiles only by PhotoTOP oxidation. The results show that when applied directly to textile samples, oxidation by dTOP and PhotoTOP and also hydrolysis by the THP are able to capture large fractions of the TF in form of perfluoroalkyl side-chains present in the textiles while methods relying on extracts (EOF, target and non-target analysis) were much lower (e.g., factor ~25-50 lower). The conversion of large fractions of the measured TF into PFCAs or FTOHs from fluorinated side chains is in contrast to previous studies. Concentrations ranged from