TY - CONF A1 - Horn, Wolfgang A1 - Müller, Birgit T1 - Low-odour and low-emission indoor products - Nose vers. odour threshold values N2 - To achieve good air quality in buildings, it is necessary to remove, avoid or reduce cleaning loads through ventilation. To reduce the cleaning loads and their effect on the odour perception of the occupants, a sensory test in indoor spaces and on building products is necessary in addition to VOC emission measurements of the contaminants. ISO 16000-28 provides the basis for odour assessment of products using a human olfactory panel. Through many years of experience and testing of these methods, it can now be assumed that reproducible odour ratings are available for many products used indoors. An odour measurement is mandatory for the Blue Angel for carpets and is being tested for environmentally friendly resilient floor coverings. Based on the results of an earlier project and new results of the upcoming study, the ISO should be revised and completed. The project investigates the odour and VOC emissions of building products based on natural raw materials. The data generated is used to address several issues, which are briefly explained below. Floor coverings based on linoleum and rubber are included in the Blue Angel eco-label with an odour assessment. The aim of the project is to clarify whether other assessment methods in addition to intensity can provide better information. Positive hedonics have an influence on the intensity assessment. Typically, building products show high intensity with low hedonic values. Results for wood-based products often show high intensity and positive hedonics. Based on these examples, an appropriate odour assessment of wood-based products for the Blue Angel, supported by research results, should be possible. The concept of the odour guide value which is based on odour threshold values was renewed in 2023. This approach will now be compared with the standardised odour measurement (16000-28). This assessment is based on GC/MS measurements and uses odour thresholds analytically when panel-based odour assessment is not possible. For this procedure well defined odour thresholds are necessary T2 - AIRMON 2025 The 11th International Symposium on Modern Principles of Air Monitoring and Biomonitoring. CY - Loen, Norway DA - 15.06.2025 KW - Emission KW - Indoor air quality KW - Materials emissions test KW - VOC KW - Geruch PY - 2025 UR - https://stami.no/en/wp-content/uploads/sites/2/2025/06/Programhefte-Airmon-2025-Juni-10-YTH.pdf AN - OPUS4-63634 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - VOC-Sampling inside display cases with focus on BEMMA evaluation N2 - Museum display cases aim to protect art and cultural goods not only from theft and vandalism, but also from dirt and dust. An often-heard argument within a call for tender of new display cases is that there should be no emission inside of the display case. This is nearly impossible for new ones especially when they must also fulfill the requirement of an air change rate of less than 0.1 per day. For example, constructions or decorations in exhibition spaces, storage containers in depot rooms, and exhibition display cases release volatile substances that might lead to irreversible changes or, under certain circumstances, damage to the stored or displayed objects. In Germany beneath the well-established Oddy-test also the BEMMA procedure is used to evaluate the construction materials. For larger amounts of display cases control measurements of VOCs at the end of construction or buildup is quite common. However, what is necessary to measure the air inside of display cases. What are the circumstances when the display cases were closed before the test period? Is it possible to organize a clean environment for reliable measurements. How comparable are the resulting VOCs with results from BEMMA test and control measurement at the end. The BEMMA procedure should include a further VOC-test at 60 °C. What are the benefits of this enlargement. Mainly materials that have a high potential to store VOCs inside of the material in combination with a less permeable surface should be evaluated stricter than others. T2 - IAQ 2024 The International Conference on Indoor Air Quality in Heritage and Historic Environments CY - New York, USA DA - 18.11.2024 KW - Emission KW - Air quality KW - Display cases KW - VOC PY - 2024 AN - OPUS4-61967 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Odour testing of building products: Examinations for an on-going development of the test standard ISO 16000-28 N2 - VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Building material KW - Odour KW - Perceived intensity KW - VOC KW - Emission test chamber PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580070 SP - 345 EP - 352 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -