TY - GEN A1 - Simon, Franz-Georg A1 - Scholz, Philipp A1 - Gleis, Markus ED - Thiel, Stephanie ED - Thome-Kozminesky, Elisabeth ED - Quicker, Pater ED - Gosten, Alexander ED - Stengler, Ella T1 - Einstufung von Aschen und Schlacken aus der Abfallverbrennung im Hinblick auf die weitere Verwertung N2 - There are two mirror entries in the European Waste Catalogue for bottom ash and slag from waste incineration: 19 01 11* and 19 01 12. Entry 19 01 11* describes a waste material containing hazardous substances. It was shown that only the hazardous property HP14 (ecotoxic) is of relevance for the classification. If substances with the hazard statement code (HSC) H400, H410, H411, H412 and H413 are present in incineration bottom ash (IBA) above certain level the waste is classified as hazardous, otherwise it is non-hazardous (in this case 19 01 12). It was further shown that only Cu, Zn and Pb compounds have an impact on the classification using a summation rule: 100xΣ c(H410) + 10xΣ c(H411) + Σ c(H412). Limit value is 25 percent. It is obvious that H410 substances have the highest impact. Therefore, the knowledge of the elemental composition of IBA is not sufficient because the content of distinct chemical compounds (with the respective molecular weight) is needed. When the exact speciation is not known a worst-case approach has to be applied. A practical guideline for the estimation of HP14 was developed based on the definition of 4 substance groups: 1. Metals and alloys, 2. Water-soluble substances, 3. Oxides and carbonates and 4. Substances not soluble in weak acids. In substance group 1 only fine Zn powder has the HSC H410. Water-soluble substances are assumed to be H410 substances. Their concentrations are, however, regularly below the cut-off value of 0.1 %. The amount of substance group 3 is estimated by a selective extraction with maleic acid. According to the worst-case approach it is assumed that CuCO3xCu(OH)2 and ZnO represent the respective Cu and Zn species in IBA because these substances have the highest stochiometric factor. Even with this worst-case approach results from operators of IBA treatment plant showed that the limit value of 25 % is not exceeded. The requirements for utilization of IBA in Germany are defined in the Secondary Building Materials Decree (Ersatzbaustoffverordnung EBV) which was set into force in August 2023. Leaching methods (batch test or column test) with a liquid-to-solid ratio of 2 l/kg are applied. IBA fulfills the requirements for class HMVA-2. Actually, even a classification of IBA as hazardous (i.e 19 01 11*) would not affect utilization but handling and transport. KW - Rostasche KW - Ökotoxizität KW - Ersatzbaustoffverordnung KW - XANES-Spektroskopie PY - 2024 SN - 978-3-944310-90-9 VL - 1 SP - 402 EP - 414 PB - TK-Verlag CY - Neuruppin ET - 1 AN - OPUS4-59465 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Simon, Franz-Georg A1 - Scholz, Philipp A1 - Ling, Ruisi A1 - Koralewska, Ralf A1 - Gleis, Markus T1 - Aschen und Schlacken aus der Abfallverbrennung im Lichte der Ersatzbaustoffverordnung N2 - Aschen und Schlacken aus der thermischen Abfallbehandlung stellen mit rund 25% Massenanteil die größte Reststofffraktion dar. In Deutschland fallen pro Jahr rund 6 Millionen Tonnen an. Während sich die Verwertung der metallischen Anteile problemlos gestaltet, werden an die mineralische Fraktion Anforderungen bezüglich der möglichen Freisetzung von Schwermetallen sowie Chlorid und Sulfat gestellt. In der Ersatzbaustoffverordnung sind für Aschen und Schlacken aus der Abfallverbrennung zwei Materialklassen mit unterschiedlich hohen Anforderungen an die Umweltverträglichkeit definiert. Im Rahmen eines Forschungsprojekts wurde untersucht, ob mit Abtrennung der Feinfraktion von 0–2mm die höhere Materialklasse HMVA-1 erreicht werden kann. Im Ergebnis wurde eine Verbesserung des Auslaugverhaltens erzielt, doch nicht in dem Maß, dass eine Qualität nach HMVA-1 erreicht wird. Rostaschen halten aber die Anforderungen zur Deponierung auf einer DK I-Deponie sowie die Anforderungen zur Verwertung gemäß HMVA-2 sicher ein. KW - Rostasche KW - Auslaugtest KW - Ersatzbaustoff PY - 2024 DO - https://doi.org/10.37307/j.1863-9763.2024.07.08 SN - 1863-9763 VL - 56 IS - 7 SP - 407 EP - 411 PB - Erich Schmidt Verlag GmbH & Co. KG CY - Berlin AN - OPUS4-60601 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GOVDOC A1 - Simon, Franz-Georg A1 - Wöhlecke, Andreas T1 - 8. Nachtrag zum Zulassungsschein 12/BAM IV.3/09/00 für eine Schutzschicht bestehend aus einer sandgefüllten Schutzbahn für Kunststoffdichtungsbahnen in Deponieabdichtungen N2 - 8. Nachtrag zum Zulassungsschein 12/BAM IV.3/09/00 für eine Schutzschicht bestehend aus einer sandgefüllten Schutzbahn für Kunststoffdichtungsbahnen in Deponieabdichtungen der Fa. G quadrat GmbH, Krefeld. KW - Zulassung KW - Deponie KW - Schutzschicht KW - Kunststoffdichtungsbahn PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-604877 SP - 1 EP - 29 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-60487 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Simon, Franz-Georg A1 - Scholz, Philipp T1 - Sequential Extraction of Incineration Bottom Ash: Conclusions Regarding Ecotoxicity N2 - The classification of incineration bottom ash (IBA) as hazardous or non-hazardous according to ecotoxic hazard property HP14 is still under debate. In this context, only the compounds of Zn and Cu with the hazard statement code H410 are of relevance. With an approach based on the grouping of substances, it was shown that such substances are either readily water-soluble or slightly and sparingly soluble. The concentrations of readily soluble Cu and Zn compounds in IBA are far below the cut-off value of 0.1%. Slightly and sparingly soluble Zn and Cu compounds could be quantified in the first fraction of a four-step sequential extraction procedure. With the results from the complete sequence, the dimensionless synthesis toxicity index (STI) was calculated and was in the range of 494 to 1218 for the four investigated IBA samples. It was concluded that IBA can usually be classified as non-hazardous. KW - Incineration bottom ash KW - Hazard properties KW - Ecotoxicity KW - Sequential extraction PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-605070 DO - https://doi.org/10.3390/app14135541 SN - 2076-3417 VL - 14 IS - 13 SP - 1 EP - 12 PB - MDPI AN - OPUS4-60507 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ronen, A. A1 - Vogel, Christian A1 - Leube, Peter A1 - Ben Efraim, R. A1 - Nir, O. A1 - Chaudhary, M. A1 - Futterlieb, M. A1 - Panglisch, S. T1 - DEFEAT-PFAS: Detection, Quantification, and Treatment of Per- and Polyfluoroalkyl Substances (PFAS) in Groundwater N2 - The research project focuses on tackling the detection, measurement, and elimination of per- and polyfluoroalkyl substances (PFAS) from polluted groundwater, with a particular emphasis on addressing short (C4-C7) and ultrashort (C1-C3) chain PFAS. Given the widespread use of PFAS in various products, they are commonly found in groundwater near industrial and military sites in Germany and Israel. Moreover, recent regulations limiting the use of long chain PFAS have led industries to shift towards shorter chain alternatives. Hence, our efforts are geared towards refining detection, quantification, and removal methods for short and ultrashort chain PFAS. In terms of detection, ww are developing passive sampling devices capable of collecting and tracking the temporal distribution of PFAS species in groundwater. This will enable us to analyze contaminations in German and Israeli groundwater using cutting-edge analytical techniques. Additionally, contaminated groundwater will undergo a two-stage treatment process aimed at concentrating the relatively low PFAS concentrations using innovative membrane technologies such as closed-circuit reverse osmosis and mixed matrix composite nanofiltration membrane adsorbers. Subsequently, the streams containing higher PFAS concentrations will be treated through coagulation, with the remaining PFAS being adsorbed onto carbonaceous nanomaterials. The outcome of this research will include the creation of advanced tools for detecting, measuring, and eliminating PFAS from polluted groundwater, while also enhancing our understanding of the scope of these contaminations. T2 - German Israeli Water Technology Status Seminar CY - Koblenz, Germany DA - 18.06.2024 KW - Ground water KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Remediation PY - 2024 UR - https://indico.scc.kit.edu/event/4029/attachments/7552/12045/Proceedings_Ger-Isr-Coop_Status-Seminar-2024.pdf SP - 33 EP - 36 AN - OPUS4-60331 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ronen, A. A1 - Panglisch, S. A1 - Vogel, Christian A1 - Leube, Peter A1 - Ben Efrain, R. A1 - Nir, O. A1 - Chaudhary, M A1 - Futterlieb, M. T1 - Detection, Quantification and Treatment of Per and Polyfluoroalkyl substances (PFAS) in Groundwater N2 - The research project focuses on tackling the detection, measurement, and elimination of per- and polyfluoroalkyl substances (PFAS) from polluted groundwater, with a particular emphasis on addressing short (C4-C7) and ultrashort (C1-C3) chain PFAS. Given the widespread use of PFAS in various products, they are commonly found in groundwater near industrial and military sites in Germany and Israel. Moreover, recent regulations limiting the use of long chain PFAS have led industries to shift towards shorter chain alternatives. Hence, our efforts are geared towards refining detection, quantification, and removal methods for short and ultrashort chain PFAS. In terms of detection, ww are developing passive sampling devices capable of collecting and tracking the temporal distribution of PFAS species in groundwater. This will enable us to analyze contaminations in German and Israeli groundwater using cutting-edge analytical techniques. Additionally, contaminated groundwater will undergo a two-stage treatment process aimed at concentrating the relatively low PFAS concentrations using innovative membrane technologies such as closed-circuit reverse osmosis and mixed matrix composite nanofiltration membrane adsorbers. Subsequently, the streams containing higher PFAS concentrations will be treated through coagulation, with the remaining PFAS being adsorbed onto carbonaceous nanomaterials. The outcome of this research will include the creation of advanced tools for detecting, measuring, and eliminating PFAS from polluted groundwater, while also enhancing our understanding of the scope of these contaminations. T2 - German Israeli Water Technology Status Seminar CY - Koblenz, Germany DA - 18.06.2024 KW - Ground water KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Remediation PY - 2024 AN - OPUS4-60328 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Simon, Franz-Georg A1 - Vogel, Christian A1 - Leube, Peter T1 - Detektion, Quantifizierung und Entfernung von insbesondere ultrakurzkettigen PFAS in Grundwasser N2 - Da PFAS in großem Umfang in einer Vielzahl von Produkten verwendet wurde, sind sie im Grundwasser in der Nähe vieler industrieller und militärischer Anlagen weltweit zu finden. Darüber hinaus führten neue Vorschriften und Beschränkungen für die Verwendung von langkettigen PFAS zu einer vermehrten Produktion kurzkettiger Alternativen. Ultrakurzkettige PFAS (≥C3) können natürliche und anthropogene Barrieren durchdringen und schließlich in Trinkwasserquellen gelangen. Zudem entfernen die meisten gängigen Trinkwasser-aufbereitungsverfahren die ultrakurzkettigen PFAS nicht ausreichend. Im Kooperationsprojekt DEFEAT-PFAS wird daher das Ziel verfolgt, Wissenslücken über Nachweis, Quantifizierung und Entfernung von kurz- (C4-C7) und ultrakurzkettige (C1-C3) PFAS, in kontaminiertem Grundwasser zu schließen. Die israelischen und deutschen Projektpartner entwickeln dafür analytische Methoden and selektive Passivsammler, um das zeitliche Profil von PFAS-Spezies im Grundwasser zu erfassen und überwachen. Darüber hinaus ein zweistufiges Verfahren entwickelt, welches darauf ausgelegt ist, die relativ niedrigen PFAS-Konzentrationen im Grundwasser durch neuartige Membranverfahren, Umkehrosmose im Batchbetrieb mit geschlossenem Kreislauf sowie Verbund-Nanofiltrationsmembranen, zu konzentrieren. Anschließend werden die PFAS angereicherten Konzentrate mittels Koagulation behandelt und das verbleibende PFAS an kohlenstoffhaltigen Nanomaterialien adsorbiert. T2 - Workshop des Netzwerks Perflusan CY - Karlsruhe, Germany DA - 18.06.2024 KW - Grundwasser KW - Per- und Polyfluoroierte Alkylsubstanzen (PFAS) PY - 2024 AN - OPUS4-60334 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Leube, Peter A1 - Vogel, Christian A1 - Simon, Franz-Georg T1 - Quantification of ultrashort per- and polyfluoroalkyl substances (PFAS) in water samples via headspace gas chromatographymass spectrometry (GC-MS) - a method development N2 - Ultrashort PFAS (≤ 3 carbon atoms) were overlooked for a long time in analytical monitoring. Beside through the use of these substances, they contribute to the PFAS background in the environment through (environmental/ bio-) degradation and incomplete destruction3 of PFAS with longer carbon chains or other fluorinated compounds. As part of the German-Israeli Cooperation in Water Technology Research project „Detection, quantification, and treatment of per- and polyfluoroalkyl substances in groundwater“ (DEFEAT-PFAS), we are developing an as simple as possible direct headspace (HS-)GC-MS method to detect trifluoroacetic acid (TFA) and perfluoropropanioc acid (PFPrA), as well as trifluoroethanol (TFEtOH), pentafluoropropanol(PFPrOH) and hexafluoroiospropanol (HFIP) in water samples. Here we present the results of the PFAS mentioned in spiked ultrapure water solutions. T2 - German Israeli Water Technology Status Seminar CY - Koblenz, Germany DA - 18.06.2024 KW - Ground water KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Gas chromatography - mass spectrometry (GC-MS) PY - 2024 AN - OPUS4-60330 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ben Efraim, R. A1 - Vogel, Christian A1 - Leube, Peter A1 - Nir, O. A1 - Chaudhary, M. A1 - Futterlieb, M. A1 - Panglisch, S, A1 - Ronen, A, T1 - Comparison of PFAS Adsorption and Electro-Sorption Using Pristine and Functionalized MWCNTs N2 - Per- and polyfluoroalkyl substances (PFAS) have been extensively utilized in various industrial processes, resulting in elevated concentrations in landfills and drinking water reservoirs. Despite recognizing that shortchained PFAS are harmful, they are often overlooked. Short-chain PFAS are more challenging to remove via adsorption and membrane separation processes, and their detection is complex, thus creating a critical gap in understanding their environmental impact. To improve their environmental monitoring, we aim to improve short-chain PFAS adsorption and electro-sorption on novel carbon-based adsorbers such as pristine and functionalized multi-walled carbon nanotubes (MWCNTs) and assess their adsorption mechanisms. Based on the obtained result, we aim to develop a PFAS passive sampling device. T2 - German Israeli Water Technology Status Seminar CY - Koblenz, Germany DA - 18.06.2024 KW - Ground water KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Sorption PY - 2024 AN - OPUS4-60329 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Leube, Peter A1 - Vogel, Christian A1 - Simon, Franz-Georg T1 - Quantification of ultrashort per- and polyfluoroalkyl substances (PFAS) in water samples via headspace gas chromatography-mass spectrometry (GC-MS) - a method development N2 - Per- and polyfluoroalkyl substances (PFAS) were classified as a group of highly concerning chemicals over the last decades. Because of the high persistence of PFAS, their previous use led to contamination of the environment and human population. Due to ongoing use and incomplete remediation or destruction methods, the PFAS background in the environment is growing continuously. The presence of ultrashort PFAS (with ≤3 carbon atoms) in the environment is often overlooked despite their contributions to PFAS levels. These compounds may directly contaminate the environment and arise from degradation of polyfluorinated compounds as well as incomplete PFAS destruction in certain industrial processes. Nonetheless, few approaches for targeted analysis of ultrashort PFASs have been developed, except for trifluoroacetic acid (TFA). Beside liquid (LC-MS/MS), supercritical fluid (SFC-MS/MS), and ion chromatography (IC-MS)-based systems, gas chromatography coupled with mass spectrometry (GC-MS) is a promising method for detection and quantification of ultrashort PFAS. The goal of this study was to develop a simple headspace GC-MS method for the quantification of ultrashort perfluorocarboxylic acids (PFCAs) and polyfluorinated alcohols (PFOHs) in water samples. In contrast to PFOHs, functionalization of PFCAs was required for quantification. This was done by esterification with methanol at 80 °C, which can be carried out directly in the headspace GC-MS system. Moreover, several parameters were optimized to achieve a low limit of quantification (LOQ) for the analytes used: i) The ratio of the aqueous solution, methanol, and available gas phase within the analysis vessel, ii) the concentration of additional acid in esterification mixtures of PFCAs, iii) shaking frequency and iv) shaking time before analysis. After optimizing the procedure, we were able to quantify ultrashort PFCAs and PFOHs. Thus, our developed headspace GC-MS method has the potential to be used as an alternative target analysis for ultrashort-chain PFCAs and PFOHs in various water samples (groundwater, wastewater). T2 - SETAC Europe 34th Annual Meeting CY - Seville, Spain DA - 05.05.2024 KW - Ultrashort PFAS KW - Headspace GC-MS KW - Perfluorocarboxylic acid (PFCA) KW - Polyfluorinated alcohol (PFOH) PY - 2024 AN - OPUS4-60042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -