TY - CONF A1 - Bonse, Jörn T1 - Impact of laser-induced periodic surface structures on the bactericidal properties of copper and brass N2 - Surfaces of metallic copper and copper alloys effectively inactivate microorganisms and viruses. However, the exact inactivation mode is still under debate. Main factors are assumed to include direct contact with the metallic surface, influx of Cu(I)/Cu(II) ions and the generation of reactive oxygen species (ROS). Laser-induced periodic surface structures (LIPSS) are frequently reported to act antibacterial, mainly by prevention of bacterial adhesion due to a limited number of possible adhesion points or by increasing the overall surface of intrinsically antibacterial materials. In time-kill experiments with E. coli and S. aureus we analyzed the impact of LIPSS on the toxicity of metallic copper and brass. We also conducted ROS accumulation assays and conclude that the application of LIPSS is not generally straight forward to obtain or improve antibacterial surfaces. Thus, the antibacterial effects of LIPPS. T2 - 2023 Spring Meeting CY - Strasbourg, France DA - 29.05.2023 KW - LIPSS KW - Antimicrobial KW - Reactive oxygen species PY - 2023 AN - OPUS4-58465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ulbricht, Alexander T1 - Do Microbes like Additively Manufactured Aluminium? First Details of a Corrosion Test using Sulphate-Reducing Bacteria N2 - Additively manufactured metals become relevant for industrial application. Although many studies on wet corrosion of these metals have been conducted, to the authors knowledge no study seems to contain microbiological corrosion (MIC). In the presented study an experiment was conducted on PBF-LB/AlSi10Mg to test this material's susceptibility for MIC. The tested specimen were analysed using Computed Tomography before and after the MIC experiment to enable a detailed characterisation the damage on the specimens' global and local level. A global reduction of material was observed. In addition, localised damage along process inherent features of the materials microstructure was observed. T2 - Beiratssitzung TF Umwelt CY - Berlin, Germany DA - 17.03.2025 KW - Computed Tomography KW - Additive Manufacturing KW - Biocorrosion KW - Sulphate-reducing Bacteria KW - Microbially influenced corrosion PY - 2025 AN - OPUS4-62772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bonnerot, Olivier T1 - Are X-rays safe for manuscripts’ materials? N2 - In the last decade, applications of X-rays to the study of manuscripts significantly spread in both diversity and extent. They range from writing material analysis, mostly with X-ray fluorescence (XRF), permitting non-invasive characterization of inks and pigments used, to the investigation of the origin of writing supports. In addition, XRF mapping has proved to be an invaluable tool for recovering erased text. Finally, computed-tomography (CT) has shown potential in virtually unrolling rolls, making text readable without using-damaging mechanical methods. Despite their growing use, little attention has been paid to the side effects of such analytical tools. We observed irreversible parchment colour changes during some experiments on dead-sea scrolls with synchrotron radiation sources. Furthermore, partial photo-reduction of iron under high intensity beam during X-ray absorption near edge structure spectroscopy (XANES) measurements of iron-gall ink on paper has been reported several times [5,6]. Such phenomena have mostly been overlooked so far, although there is an increasing awareness of the necessity to study them. We conducted experiments at the Deutsches Elektronen-Synchrotron (DESY) facilities to investigate X-ray induced structural alteration of paper and parchment to see whether the presence of absorption centres (ink and pigments) has an impact. In addition to better understanding degradation processes, we are aiming to define an appropriate methodology of analysis of manuscripts with a tolerable risk of damage. The first results concerning X-ray induced damage of cellulose materials have already been presented at the Synchrotron Radiation and Neutrons in Art and Archaeology (SR2A). We are focusing here on the results on parchment materials. T2 - Cultural and Natural Heritage Workshop CY - Grenoble, France DA - 22.01.2020 KW - X-rays KW - Manuscripts KW - Parchment KW - Synchrotron PY - 2020 AN - OPUS4-50305 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogel, Christian T1 - Per- and polyfluoroalkyl substances (PFAS) in ski waxes and snow from cross-country skiing in Germany - Comparative study of target analysis and sum parameters N2 - Per- and polyfluoroalkyl substances (PFAS) can enter the environment in different ways. Possible sources are PFAS containing consumer products. One common product that makes use of the material properties of PFAS is ski wax. Here, the PFAS ensure less frictional resistance, thus allows for increased speed. However, people who wax their ski with these waxes could absorb PFAS in their body, which can lead to health problems in the long term. Moreover, PFAS applied in ski wax abrade onto snow during use, which contaminates the environment. In our study, we analyzed various currently available ski waxes (2020s) and ski waxes from the 1980s with PFAS target analysis and with the sum parameters extractable organically bound fluorine (EOF), hydrolysable organically bound fluorine (HOF) and total fluorine (TF). Moreover, snow samples from the long-distance cross-country ski trail “Kammloipe” in the Ore mountains in Germany where sampled and analyzed with PFAS target analysis and the adsorbable organically bound fluorine (AOF) sum parameter to document the entry of PFAS from ski waxes into the environment. In opposite to the ski waxes from the 1980s much more ski waxes from the 2020s contain high (total) fluorine values. The highly fluorinated ski waxes contain up to approx. 6% of fluorine. The EOF and HOF sum parameters of the ski waxes are strongly decreased in comparison to the TF values (max. approx. 1000 mg/kg = 0.1%). But even the PFAS-free labeled ski waxes have EOF/HOF values in the low mg/kg range. In the snow samples from different spots of the ski trail, both the AOF sum parameter and the PFAS target analysis identified PFAS. Moreover, on a PFAS hotspot also soil samples were analyzed, which indicate that PFAS from the ski waxes adsorb after snow melting into the soil. Thus, our results show that the use of ski waxes is a possible contribution to the environmental contamination of PFAS, which is hopefully drastically reduced with the ban on fluorinated waxes by the International Ski and Snowboard Federation (FIS). T2 - SETAC Europe CY - Vienna, Austria DA - 11.05.2025 KW - Per- and polyfluoroalkyl substances (PFAS) KW - Contaminated Soil KW - Ski wax PY - 2025 AN - OPUS4-63096 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Röllig, Mathias T1 - Thermografie zur Vergleichbarkeit von Emissionsmessung im 3D-Druck N2 - Die Bedeutung der Extrudertemperatur bei kleinen Desktop 3D Druckern der Fused Filament Fabrication (FFF) Technologie auf die Emission von ultrafeinen Partikeln im Druckbetrieb ist nicht zu unterschätzen. Allerdings zeigen kommerzielle 3D Drucker häufig eine systematische Temperaturabweichung zum Sollwert, d.h. die eingestellte Temperatur weicht von der tatsächlichen Temperatur ab. Da die Partikelemission meist temperaturabhängig ist, ist eine genaue Messung der tatsächlichen Extrudertemperatur für den Vergleich von Emissionsdaten aus unterschiedlichen Druckermodellen relevant. T2 - DGZfP Jahrestagung 2025 CY - Berin, Germany DA - 26.05.2025 KW - Thermografie KW - Fused Filament Fabrication (FFF) KW - Ultrafeine Partikel KW - Extrudertemperatur KW - Temperaturmessung PY - 2025 AN - OPUS4-63328 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogel, Christian T1 - Diffusive Gradients in Thin-films (DGT) technique as screening tool for per- and polyfluoroalkyl substances (PFAS) contamination in wastewater-based fertilizers N2 - Per- and polyfluoroalkyl substances (PFAS) are a large group of organofluorine surfactants used in the formulations of thousands of consumer goods, including aqueous film-forming foams (AFFF) used to suppress aviation fires in training scenarios, non-stick cookware, fast-food wrappers, water-repellent fabrics, medical equipment, and plastic and leather products. As a result of the perpetual use of PFAS containing products, effluents and sewage sludge from wastewater treatment plants (WWTPs) have been observed to be an important pathway for PFAS into the environment. In Germany, phosphorus and other nutrients from sewage sludge and wastewater should be recycled in WWTPs of cities with a large population. However, it is not clear if PFAS contamination from wastewater and sewage sludge end up in novel wastewater-based fertilizers. Normally, PFAS are analyzed using PFAS protocols typically with time-consuming extraction steps and LC-MS-MS quantification. However, for screening of PFAS contaminations in sewage sludge or wastewater-based fertilizers also passive sampler based on the Diffusive Gradients in Thin-films (DGT) technique can be used for the PFAS extraction. Afterwards, combustion ion chromatography (CIC) can be applied to analyse the “total” amount of PFAS on the passive sampler. Here, we show results from the DGT method in comparison to those of the extractable organic fluorine (EOF) method for a variety of wastewater-based fertilizers. Additionally, we analysed the adsorption of PFAS on the weak anion exchanger (WAX) based DGT passive sampler binding layer by infrared and fluorine K-edge X-ray adsorption near-edge structure (XANES) spectroscopy. T2 - SETAC Europe 2022 CY - Copenhagen, Denmark DA - 15.05.2022 KW - Passive sampling KW - Per- and Polyfluoroalkyl substances (PFAS) KW - Sewage sludge KW - Wastewater PY - 2022 AN - OPUS4-54883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp T1 - How to investigate potential emission sources of PFAS in consumer product materials? Comparative extraction approaches and sum parameter analysis by combustion ion chromatography (CIC) N2 - Besides classical per- and polyfluorinated alkylated substances (PFAS), side-chain fluorinated polymers (SFPs) are widely applied as efficient anti-wetting and anti-greasing coatings in various daily applicated consumer products such as outdoor apparel, carpetry or paper-based food contact materials. Although the fluorinated sidechains are chemically bound to a base polymer, their release can be triggered by environmental influences or wear-off, thus contribute as significant sources of PFAS in the environment. Since only little knowledge of PFAS and SFP composition in consumer products is available, a comprehensive analytical approach might be beneficial. T2 - SETAC Konferenz 2023 CY - Dublin, Ireland DA - 30.04.2023 KW - PFAS KW - Combustion Ion Chromatography KW - Comsumer good samples PY - 2023 AN - OPUS4-57422 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Musyanovych, A. A1 - Grimmer, Christoph A1 - Sadak, A. E. A1 - Heßling, L. A1 - Bilsel, M. A1 - Horn, Wolfgang A1 - Richter, Matthias T1 - Polymeric Capsules with VOCs for Controlled Emission N2 - Micro-(nano-)encapsulation technology involves building of a barrier between the core and the environment and offers a number of benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of the payload. Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ [1] was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air. Different capsules in a size range between 5 and 50 μm were synthesized through an interfacial polyaddition/polycondensation reaction in direct (water-in-oil) system. As VOC several types of hydrophobic liquid materials were used. After synthesis, the morphology and physicochemical properties of capsules were characterized by electron microscopy, FTIR and DSC/TGA. An encapsulation efficiency up to 90% could be reached. The emission kinetic of volatile agents was studied in emission test chambers at 23 °C and 50% RH for 14 days. First results indicate that variation of the cross-linking grade of the shell material is one important parameter to adjust the desired emission rate. The overall aim is to achieve a consistent emission profile that decreases by less than 10 % over a target period of at least 14 days. T2 - 36th European Colloid & Interface Society Conference CY - Chania, Crete, Greece DA - 04.09.2022 KW - Capsules KW - Volatile organic compound KW - Polymer KW - Material emissions KW - Reference materials PY - 2022 AN - OPUS4-56039 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Musyanovych, A. T1 - Polymeric Capsules with VOCs for Controlled Emission N2 - Micro-(nano-)encapsulation technology involves building a barrier between the core and the environment and offers several benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of loaded compounds. Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air. T2 - 36th European Colloid & Interface Society Conference CY - Chania, Crete, Greece DA - 04.09.2022 KW - Capsules KW - Volatile organic compounds KW - Material emissions KW - QA/QC KW - Reference materials PY - 2022 AN - OPUS4-55917 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Strzelczyk, Rebecca T1 - Zeolites loaded with VOCs as reference for material emissions testing N2 - Nowadays, people spend most of their time indoors. Thus, a good indoor air quality is important. Emissions of volatile organic compounds (VOCs) from furniture and building materials can cause health complaints1. Quantitative VOC-emission testing is carried out under standardized conditions in emission test chambers. In the presented project an emission reference material (ERM) is developed that emits a defined mixture of VOCs which is required for quality assurance and -control (QA/QC) measures. Porous materials (e.g zeolites, activated carbons, MOFs or aerogels) are used as reservoir materials and impregnated with VOC. The porous materials are selected, among others, by their pore size, pore size distribution, polarity and availability. Due to their regular pore structure zeolites are tested at first. For a prediction of the emission profile, the ERM is supposed to exhibit a constant emission rate over time. The aim is a stability of ≤ 10 % change in the emission rate over a minimum of 14 days. Method For impregnation, the material is placed into an autoclave inside a rotatable basket. The VOC is added and the autoclave is closed. Afterwards, CO2 is inserted. The closed system is then heated to the supercritical point of CO2 (31 °C, 73.75 bar). In this state, the CO2 acts as solvent for the VOC. By rotating the basket, the distribution of the VOC is ensured. After a few minutes, the pressure is decreased slowly and the CO2 is released. For the determination of the emission profile, the impregnated sample is placed into an emission test chamber. These chambers can be operated either with dry or humid air (50 ± 5 % rel. humidity). Every second to third day, air samples are taken and analyzed by gas chromatography. For an ideal impregnation, several different pressures and temperatures as well as impregnation times are tested. Results Two zeolite materials tested in dry air conditions reach emission profiles with a decrease of less than 10 % over 14 days (heptane and toluene, respectively). Further it was discovered that smaller pellets of the same zeolite show better results than bigger particles. When the pore size of a zeolite is too small, e.g. 0.3 nm, the VOC cannot be absorbed sufficiently. The main disadvantage of zeolites is their hygroscopicity because it has a large impact on the release of VOC when they are used in emission test chambers under standardized test conditions (23 °C, 50 % rel. humidity). Activated carbons have emission profiles with a larger change over 14 days. However, the high hydrophobicity allows measurements in humid air conditions which was not possible with the before mentioned hygroscopic zeolites. It is possible to impregnate powdered materials as well, and thus powdered non-hygroscopic (n.h.) zeolites were impregnated. Their emission profiles are comparable to those of the activated carbons. The use of methylated hygroscopic zeolites with a decrease in hygroscopicity did not yield successful emission measurements. The change over 14 days is calculated only for the stable phase (~250–300 h). The desired stability of ≤ 10 % change of the emission rate over 14 days could already be reached under dry testing conditions. Further investigations under humid conditions show that zeolites with high Si/Al-ratios are non-hygroscopic and comparable to activated carbons (20–30 % change). The next step is to reduce the change in the emission rate of these materials to the aimed ≤ 10 % over 14 days. T2 - Deutsche Zeolithtagung CY - Jena, Germany DA - 28.02.2024 KW - VOC KW - Emission KW - Quality assurance KW - Reference material KW - Zeolite PY - 2024 AN - OPUS4-59843 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -