TY - JOUR A1 - Seeger, Stefan A1 - Osan, J. A1 - Czömpöly, O. A1 - Gross, A. A1 - Stosnach, H. A1 - Stabile, L. A1 - Ochsenkuehn-Petropoulou, M. A1 - Tsakanika, L. A1 - Lymperopoulou, T. A1 - Goddard, S. A1 - Fiebig, M. A1 - Gaie-Levrel, F. A1 - Kayser, Y. A1 - Beckhoff, B. T1 - Quantification of Element Mass Concentrations in Ambient Aerosols by Combination of Cascade Impactor Sampling and Mobile Total Reflection X-ray Fluorescence Spectroscopy N2 - Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments, as well as for enforcing EU air quality regulations. Typically, airborne particles are sampled over long time periods on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). During the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling is combined for the first time with on-site total reflection X-ray fluorescence (TXRF) spectroscopy to develop a tool for quantifying particle element compositions within short time intervals and even on-site. This makes variations of aerosol chemistry observable with time resolution only a few hours and with good size resolution in the PM10 range. The study investigates the proof of principles of this methodological approach. Acrylic discs and silicon wafers are shown to be suitable impactor carriers with sufficiently smooth and clean surfaces, and a non-destructive elemental mass concentration measurement with a lower limit of detection around 10 pg/m3 could be achieved. We demonstrate the traceability of field TXRF measurements to a radiometrically calibrated TXRF reference, and the results from both analytical methods correspond satisfactorily. KW - TXRF KW - Reference method KW - Cascade impactor KW - Ambient aerosols KW - Particles KW - Air quality monitoring KW - Element mass concentration KW - Size resolved chemical composition KW - Time resolved chemical composition KW - ICP-MS PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521860 UR - http://www.aerometproject.com/ DO - https://doi.org/10.3390/atmos12030309 SN - 2073-4433 VL - 12 IS - 3 SP - 309 EP - 337 PB - MDPI CY - Basel, Schweiz AN - OPUS4-52186 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Even, Morgane T1 - Formaldehyde Emissions from Wooden Toys: Method Comparison and Exposure Assessment N2 - Formaldehyde is considered as carcinogenic and is emitted from particleboards and plywood used in toy manufacturing. Currently, the flask method is frequently used in Europe for market surveillance purposes to assess formaldehyde release from toys, but its concordance to levels measured in emission test chambers is poor. Surveillance laboratories are unable to afford laborious and expensive emission chamber testing to comply with a new amendment of the European Toy Directive; they need an alternative method that can provide reliable results. Therefore, the application of miniaturised emission test chambers was tested. Comparisons between a 1 m3 emission test chamber and 44 mL microchambers with two particleboards over 28 days and between a 24 L desiccator chamber and the microchambers with three puzzle samples over 10 days resulted in a correlation coefficient r2 of 0.834 for formaldehyde at steady state. The correlation between the results obtained in microchambers vs. flask showed a high variability over 10 samples (r2: 0.145), thereby demonstrating the error-proneness of the flask method in comparison to methods carried out under ambient parameters. An exposure assessment was also performed for three toy puzzles: indoor formaldehyde concentrations caused by puzzles were not negligible (up to 8 μg/m3), especially when more conservative exposure scenarios were considered. T2 - OE conference CY - Online meeting DA - 23.03.2021 KW - Formaldehyde KW - Wooden toys PY - 2021 AN - OPUS4-52330 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Even, Morgane A1 - Juritsch, Elevtheria A1 - Richter, Matthias T1 - Measurement of very volatile organic compounds (VVOCs) in indoor air by sorbent-based active sampling: Identifying the gaps towards standardisation N2 - The ISO 16000-6 standard describes a method for the determination of volatile organic compounds (VOCs) in indoor and test chamber air by sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (GC/MS). It also gives directions to adapt this methodology to very volatile organic compounds (VVOCs). Indeed, toxicologically based guideline values are being implemented for these compounds and it becomes necessary to measure them. But a comprehensive and robust measurement method is lacking. This work highlights the points that still need to be explored towards the standardisation of a suitable procedure: investigations on sorbent combinations, the suitability of chromatography columns and the use of gaseous standards are required. The biggest challenge remains in the fact that strong sorbents adsorb water together with VVOCs. Water may impair the analysis and the optimal approach to eliminate it is still to be found and integrated into the sampling strategy. KW - Solvents KW - Air analysis KW - VOC KW - Thermal desorption KW - Gas chromatography KW - ISO 16000-6 PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-523919 DO - https://doi.org/10.1016/j.trac.2021.116265 VL - 140 SP - 116265 PB - Elsevier B.V. AN - OPUS4-52391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Contaminants of Emerging Concern from Materials and Products: Measurement and Evaluation N2 - Test chamber measurements are an important tool to improve indoor air quality and occupational safety. Test chamber measurements are possible for a wide range of materials, products and technologies. Determination of concerning contaminants is important to ensure good indoor air quality. The detection of concerning contaminants depends on the approriate sampling and analysis. T2 - Webinar BAM-University of Birmingham CY - Online meeting DA - 24.02.2021 KW - Emerging Contaminants KW - Emission Test Chamber KW - Thermal Extraction KW - Thermal Desorption PY - 2021 AN - OPUS4-52262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Even, Morgane T1 - Formaldehydemissionen aus Holzspielzeug: Methodenvergleich und Expositionsabschätzung N2 - Formaldehyd gilt als krebserregend und wird von Spanplatten und Sperrholz emittiert, die bei der Spielzeugherstellung verwendet werden. Die Untersuchungsänter benötigen eine wirtschaftliche und zuverlässige Methode. Die Anwendung miniaturisierter Emissionsprüfkammern wurde getestet und mit größeren Emissionsprüfkammern und die Flaschenmethode verglichen. Eine Expositionsabschätzung wird auch vorgestellt. T2 - 28. WaBoLu-Innenraumtage CY - Online Meeting DA - 10.05.2021 KW - Formaldehyd KW - Emission KW - Spielzeug KW - Methoden PY - 2021 AN - OPUS4-52628 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horender, S. A1 - Auderset, K. A1 - Quincey, P. A1 - Seeger, Stefan A1 - Skov, S. N. A1 - Dierschel, K. A1 - Smith, T. O.M. A1 - Williams, K. A1 - Aegerter, C. C. A1 - Kalbermatter, D. M. A1 - Gaie-Levrel, F. A1 - Vasilatou, K. T1 - Facility for production of ambient-like model aerosols (PALMA) inthe laboratory: application in the intercomparison of automated PMmonitors with the reference gravimetric method N2 - A new facility has been developed which allows for a stable and reproducible production of ambient-like model aerosols (PALMA) in the laboratory. The set-up consists of multiple aerosol generators, a custom-made flow tube homogeniser, isokinetic sampling probes, and a system to control aerosol temperature and humidity. Model aerosols containing elemental carbon, secondary organic matter from the ozonolysis of α-pinene, inorganic salts such as ammonium sulfate and ammonium nitrate, mineral dust particles,and water were generated under different environmental conditions and at different number and mass concentrations. The aerosol physical and chemical properties were characterised with an array of experimental methods, including scanning mobility particle sizing, ion chromatography, total reflection X-ray fluorescence spectroscopy and thermo-optical analysis. The facility is very versatile and can find applications in the calibration and performance characterisation of aerosol instruments monitoring ambient air. In this study, we performed, as proof of concept, an intercomparison of three different commercial PM (particulate matter) monitors (TEOM1405, DustTrak DRX 8533 and Fidas Frog) with the gravimetric reference method under three simulated environmental scenarios. The results are presented and compared to previous field studies. We believe that the laboratory-based method for simulating ambient aerosols presented here could provide in the future a useful alternative to time-consuming and expensive field campaigns, which are often required for instrument certification and calibration. KW - Model aerosols KW - Intercomparison KW - PM monitors KW - Aerosol gravimetry PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521342 DO - https://doi.org/10.5194/amt-14-1225-2021 VL - 14 IS - 2 SP - 1225 EP - 1238 PB - Copernicus Publications AN - OPUS4-52134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Even, Morgane A1 - Hutzler, C. A1 - Wilke, Olaf A1 - Luch, A. T1 - Emissions of volatile organic compounds from polymer-based consumer products: comparison of three emission chamber sizes N2 - The ISO 16000 standard series provide guidelines for emission measurements of volatile organic compounds (VOCs) from building materials. However, polymer-based consumer products such as toys may also release harmful substances into indoor air. In such cases, the existing standard procedures are unsuitable for official control laboratories due to high costs for large emission testing chambers. This paper aims at developing and comparing alternative and more competitive methods for the emission testing of consumer products. The influence of the emission chamber size was investigated as smaller chambers are more suited to the common size of consumer products and may help to reduce the costs of testing. Comparison of the performance of a 203 l emission test chamber with two smaller chambers with the capacity of 24 l and 44 ml, respectively, was carried out by using a polyurethane reference material spiked with 14 VOCs during the course of 28 days. The area-specific emission rates obtained in the small chambers were always similar to those of the 203 l reference chamber after a few hours. This implies that smaller chambers can provide at least useful numbers on the extent of polymer-based consumer product emissions into indoor air, thereby supporting meaningful exposure assessments. KW - Comparison KW - Consumer products KW - Emission chamber KW - Reference material KW - Volatile organic compounds PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-493697 DO - https://doi.org/10.1111/ina.12605 VL - 30 IS - 1 SP - 40 EP - 48 PB - Wiley VCH-Verlag AN - OPUS4-49369 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ahlawat, A. A1 - Seeger, Stefan A1 - Gottschalk, Martin A1 - Tuch, T. A1 - Wiedensohler, A. T1 - Observation of systematic deviations between Faraday cup aerosol electrometers for varying particle sizes and flow rates - results of the AEROMET FCAE workshop N2 - Condensation particle counters (CPCs) are widely used for the measurement of aerosol particle number concentrations in the size range from approximately 3 nm to 3 μm. For an SI-traceable calibration of the size-dependent counting efficiency, which is advisable on a regular basis and required in several applications, Faraday cup aerosol electrometers (FCAEs) are considered to be a suitable SI-traceable reference.While the volumetric aerosol inlet flowrate and the electrical current measurement in FCAEs can be related to respective SI references, inter-comparison exercises for FCAEs are still performed on a regular basis to establish reliable uncertainty budgets and to further investigate the influences of designs and operational parameters on comparability. This is strongly demanded in the international community of metrological institutes and aerosol calibration facilities around the world, which provide CPC calibrations. In the present study, the performance of FCAEs was investigated,using Ag test aerosol particles with a 30 nm particle diameter by varying the inlet flowrates from 0.5 l min−1 to 4 l min−1. From our experimental results, significant deviations were observed in FCAE currents at sample flowrates smaller than 1.5 l min−1. It is recommended that these discrepancies should be quantified before an FCAE is used for CPC calibration at low sample flowrates and small particle sizes in the sub-30 nm size range. KW - Faraday cup aerosol electrometer KW - CPC calibration KW - Inter-comparison KW - Aerosol measurement instruments PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-531315 DO - https://doi.org/10.1088/1681-7575/ac0710 SN - 1681-7575 SN - 0026-1394 VL - 58 IS - 5 SP - 1 EP - 8 PB - Institute of Physics (IOP) CY - Bristol, UK AN - OPUS4-53131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tang, Chi-Long T1 - Chemical characterization of ultrafine particles released from 3D printers N2 - Previous studies have shown that desktop 3D printers (Fused Filament Fabrication) emit high numbers of particulate matter, mainly as ultrafine particles (UFP, particle diameter less than 100 nm). However, the chemical composition of emitted particles has been less extensively investigated. In this study, we therefore focused on the chemical composition of particles emitted from 3D printing. The measurements were conducted in a 1 m³ emission test chamber. Emitted particles were sampled by a 13-stage low-pressure cascade impactor onto aluminum foils and then analyzed by TD-GC/MS to identify their organic compounds. Nine commercial filaments made from basic polymers such as Acrylonitrile Butadiene Styrene (ABS), Acrylonitrile Styrene Acrylate (ASA), Polycarbonate (PC), Poly(methyl methacrylate) (PMMA), Nylon, High Performance Polystyrene (HIPS) and a copper-filled Polylactide (PLA) were investigated. The results show that the organic components of the particles are primarily plastic additives such as plasticizer, antioxidant agents, lubricants, UV-absorbers and UV-stabilizers from the filaments. T2 - Healthy Buildings Europe 2021 CY - Online meeting DA - 21.06.2021 KW - UFP KW - FFF-3D-Printer KW - Chemical characterization PY - 2021 AN - OPUS4-52895 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - James, G. L. A1 - Latif, M. T. A1 - Isa, M. N. M. A1 - Bakar, M. F. A. A1 - Yusuf, N. Y. M. A1 - Broughton, William A1 - Murad, A. M. A1 - Abu Bakar, F. D. T1 - Metagenomic datasets of air samples collected during episodes of severe smoke-haze in Malaysia N2 - Transboundary emissions of smoke-haze from land and forest fires have recurred annually during the dry period (June to October, over the past few decades) in South East Asia. Hazardous air quality has been recorded in Malaysia during these episodes. Agricultural practices such as slash-and-burn of biomass and peat fires particularly in Sumatera and Kalimantan, Indonesia, have been implicated as the major causes of the haze. Past findings have shown that a diversity of microbes can thrive in air including in smoke-haze polluted air. In this study, metagenomic data were generated to reveal the diversity of microorganisms in air during days with and without haze. Air samples were collected during non-haze (2013A01) and two haze (2013A04 and 2013A05) periods in the month of June 2013. DNA was extracted from the samples, subjected to Multiple Displacement Amplification and whole genome sequencing (Next Generation Sequencing) using the HiSeq 2000 Platform. Extensive bio-informatic analyses of the raw sequence data then followed. Raw reads from these six air samples were deposited in the NCBI SRA databases under Bioproject PRJNA662021 with accession numbers SRX9087478, SRX9087479 and SRX9087480. KW - Forest fires KW - Haze Samples KW - NGS KW - Multiple Displacement Amplification PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-528973 DO - https://doi.org/10.1016/j.dib.2021.107124 SN - 2352-3409 VL - 36 SP - 107124 PB - Elsevier Inc. CY - Amsterdam, Netherlands AN - OPUS4-52897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -