TY - THES A1 - Steger, Simon T1 - Non-invasive spectroscopic investigation of cultural artefacts: shedding light on modern reverse glass paintings N2 - This thesis addresses the development of a methodological approach for the non-invasive identification of colourants and for the classification of binding media in reverse glass paintings from the early 20th century. For this purpose, mobile and miniaturized devices were used to measure the paintings in situ. The methodology includes X-ray fluorescence (XRF), VIS spectroscopy (VIS), Raman spectroscopy and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). In a first step the capabilities of DRIFTS for binding media classification and pigment identification were tested. DRIFTS enables, besides Raman spectroscopy, the collection of molecular information of a substance that can be used as characteristic fingerprint spectrum. However, the simultaneous collection of both specular (surface) and diffuse (volume) reflection leads to complicated mixed DRIFT spectra, that can vary strongly for one substance depending on the dominant fraction of reflected light. Specular reflection causes several spectral distortions like inverted bands, band shifts and derivative-like features whereas pure diffuse reflections leads to an intensity enhancement of combination bands and overtones. Both specular and diffuse reflection cannot be optically separated, and their proportion depends on material properties like the absorption coefficient and the refractive index as well as on Parameters like surface roughness, porosity, grain size and angle of incidence and detection. A direct comparison of DRIFT spectra with IR spectra of other methods (e.g. transmission, ATR) is not possible, hence the creation of DRIFTS databases was needed. The next step was the complimentary utilization of Raman spectroscopy and DRIFTS for the dentification of synthetic organic colourants. Such colourants are in the further chapters called synthetic organic pigments (SOP) even when it’s not always entirely clear if they are soluble dyes or pigments that are practically insoluble in the medium in which they are incorporated. Raman spectroscopy is generally the method of choice when dealing with SOP, but fluorescence can hamper the Raman spectrum severely, inhibiting the proper identification of the pigment. DRIFTS was successfully applied and several SOP like synthetic alizarin (PR83), the yellow azo pigments (e.g. PY1) or the red and orange β-naphthol pigments (e.g. PR3) could be identified in the paintings solely by means of DRIFTS. The holistic methodological sequence was defined after the successful establishment of DRIFTS as serious analytical alternative. As the time is always the most limiting factor for in situ measurement campaigns in museums, the 9 sequence needs to be time saving but also efficient. The methodology starts with quick measurements by XRF and VIS to get a first idea of the pigment composition, followed by the validation of the results with the vibrational spectroscopies for selected points. Measurements of reverse glass paintings by Carlo Mense and Wassily Kandinsky were conducted to test the entire procedure. A high number of pigments could be identified, including several rare ones like strontium white (SrSO4), PR60 and PB52. The binding media were classified using the previously recorded references. The results were set in the art historian context and were discussed in a multidisciplinary way. The influence of Asian art, especially of Chinese reverse glass paintings as source of inspiration for artists of the “Blauer Reiter” collective (e.g. Wassily Kandinsky, Gabriele Münter, Franz Marc und Heinrich Campendonk) is shown. Non-invasive measurements of two Chinese reverse glass paintings from the late 19th and early 20th century were conducted, enabling a comparison of the palettes of Chinese and European painters. The Chinese palette includes heavy use of red lead and orpiment, pigments that were hardly sed in Europe anymore. More modern pigments like zinc white, cadmium yellow, viridian, chromates, cobalt blues or SOP were not found at all in the Chinese paintings. KW - Reverse glass painting KW - Raman spectroscopy KW - DRIFTS KW - Non invasive analysis PY - 2020 SP - 12 EP - 104 CY - Hamburg AN - OPUS4-51160 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schuehle, Florian T1 - Quality assured uptake rates for passive sampling of indoor air VOCs N2 - Generation of experimental uptake rates (UR) for > 70 VOCs (7d /100 μg m-3) Application in German Environmental Survey – VOC exposure assessment Assurance of transparency concerning UR generation and uncertainty creates basis for decision making and comparability of measurement results. Exemplarily the uncertainty u(UR) of toluene UR was modelled and determined statistically with own laboratory data (relative standard deviation of actively sampled test gas atmosphere – RSDa and n = 5 exposed passive samplers – RSDp) in line with EN 838 as well as from variation of literature UR – RSD UR,lit. T2 - Airmon 2022, 10th International Symposium on modern principles of air monitoring and biomonitoring CY - Bristol, UK DA - 06.11.2022 KW - IAQ KW - VOC KW - Diffusive sampling KW - Uptake rate PY - 2022 AN - OPUS4-56583 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sathiyamani, S. A1 - Ngiam, S. A1 - Bonnerot, O. A1 - Jaengsawang, S. A1 - Panarut, P. A1 - Helman-Wazny, Agnieszka A1 - Colini, C. T1 - Material Characterisation of 19–20th Century Manuscripts from Northern Thailand N2 - Material analysis was carried out on four manuscripts from Northern Thailand, which included two palm-leaf manuscripts and two paper manuscripts. The two palm-leaf manuscripts MS 6 and MS 7 were found to have been written in the traditional method, wherein text was incised on the surface of the leaves, and then soot applied to the surfaces, confirmed by the identification of carbon ink. MS 7 additionally showed the presence of trace levels of iron in the ink, either from soot paste or from the stylus used for inscribing. The paper manuscript MS 3 was written in iron-gall ink, with sections written using a methyl-violet based ink while MS 4 was written in carbon ink. The paper used in the case of MS 3 was found to be machine made, while khoi fibres (Streblus asper) were used for making the paper used for MS 4. A combination of traditional and modern pigments, like molybdenum orange, was used for decorating the edges and cover. The results improved our understanding of these manuscripts in particular, and also provided us with insights about the rapid adoption of modern materials and their incorporation into the production of written artefacts from Northern Thailand in the late 19th and early 20th centuries. KW - Materials analysis KW - Paper manuscript KW - Palm-leaf manuscript KW - Writing inks PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652586 DO - https://doi.org/10.1515/res-2023-0028 SN - 0034-5806 VL - 45 IS - 2-3 SP - 117 EP - 140 PB - Walter de Gruyter GmbH AN - OPUS4-65258 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Rimon, Hasia A1 - Rabin, Ira ED - Fuller, R.E. ED - Lange, A. T1 - Conservation of the Dead Sea Scrolls N2 - The current state of preservation of the DSS results from the synergetic effect of various factors such as great age, post-discovery treatments, poor storage conditions, environmental influences and exhibitions. With rare exceptions, neither the initial state nor a list of the treatments performed on each DSS fragment is known. Reconstruction of the individual fragment history will have to rely upon advanced analytical techniques to identify the treatments and their effects. Management of the scrolls may be divided roughly into three periods: a) the scholarly archiving period, from 1948 to the mid-1960s; b) first attempts at conservation, from the mid-1960s to late-1980s; c) Israel Antiquities Authority Scrolls Lab, from 1991 onwards. KW - Preservation KW - Dead Sea Scrolls PY - 2023 SN - 2468-3027 VL - 3D SP - 102 EP - 105 PB - Brill CY - Leiden / Boston AN - OPUS4-58910 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Schühle, Florian T1 - Experimental determination of 7-day uptake rates for diffusive sampling of 86 volatile and semi-volatile organic compounds relevant for indoor air monitoring and investigation on their sensitivity to exposure time and indoor climate N2 - This study aimed to experimentally determine uptake rates for 86 indoor relevant volatile and semi-volatile organic compounds (VOC, SVOC) for the passive sampler type Perkin Elmer/Markes™ with Tenax® TA as sorbent, which was used in the German Environmental Survey on Health (GerES VI) carried out by the German Environmental Agency (UBA) in the years 2023-2024. For this purpose, single reference gas atmospheres of 76 pure VOCs (liquid at room temperature) and a group of 10 SVOCs and VOCs (solid at room temperature) were generated using two generation procedures. By exposing the samplers to individual components, it was ruled out that interactions in a mixture have a influence on the uptake rate. Another aspect was to precisely describe the methodology and the resulting uncertainties, as there are gaps in the literature in this regard. The selection of the compounds was based on the findings of the preceding GerES V study for which data was missing or needed to be verified. In each experiment, a number of six passive samplers was exposed to the test gas atmospheres in dynamically operated exposure chambers for seven days. The sensitivity of the uptake rates of a group of 10 selected VOCs to variations in exposure time, ambient temperature, and air humidity in a multi-component reference gas atmosphere was investigated. Here, a decrease in the uptake rate with the exposure time could be observed stabilising from the fifth day of exposure onwards. A significant effect of temperature and humidity on the uptake rate was not apparent. The determined uptake rates exhibit uncertainties of < 20 % for 71 substances, and < 10 % for 51 substances which are also in good agreement with the literature, if already published elsewhere. The quantity of investigated substances, the detailed description of the methodology used to determine the uptake rates complemented by the respective uncertainties, as well as the compilation of comparative data, contribute to a better assessment of the quality and relevance of such data, which had not been published before. KW - Indoor air quality KW - Volatile organic compounds KW - Uptake rates KW - Passive sampling KW - Tenax TA PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-629913 DO - https://doi.org/10.1016/j.indenv.2025.100095 VL - 2 IS - 2 SP - 1 EP - 11 PB - Elsevier AN - OPUS4-62991 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias T1 - Metrological sound reference products for quality assurance and quality control measures in material emissions testing N2 - In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. Different VOC combinations may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use materials proven to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability and metrological traceability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable reference materials. The emission test chamber procedure according to EN 16516 comprises several steps from sample preparation to sampling of test chamber air and chromatographic analysis. Quality assurance and quality control (QA/QC) must therefore be ensured. Currently, there is a lack of suitable reference products containing components relevant for the health-related evaluation of building products. The EU-funded EMPIR project 20NRM04 MetrIAQ (Metrology for the determination of emissions of dangerous substances from building materials into indoor air) aims to develop 1) gaseous primary reference materials (gPRM), which are used for the certification of gaseous (certified) reference materials (gCRM) and 2) emission reference materials (ERM). Most commercial gas standards of indoor-relevant compounds are not certified due to the lack of primary reference materials to which the project aims to contribute. The gPRM under development is a gas-phase standard containing trace levels of VOCs in nitrogen or air from the check standard according to EN 16516 (n-hexane, methyl isobutyl ketone, toluene, butyl acetate, cyclohexanone, o-xylene, phenol, 1,3,5-trimethylbenzene) with a target uncertainty of 5 %. The gPRM can be sampled into sorbent tubes to obtain transfer standards in the form of gCRM. The well characterised ERM represents a sample of a test specimen, e.g. building material, that is loaded into the emission test chamber for a period of several days and is used to evaluate the whole emission test chamber procedure. It shall have a reproducible and temporally constant compound release of less than 10 % variability over 14 days. Different approaches for retarded VOC release, such as the encapsulation of pure compounds and the impregnation of porous materials, are being tested to reach this aim. Furthermore, the design of the ERM is accompanied by the development of a numerical model for the prediction of the emissions for each of the target VOCs. The current progress of the work on both materials will be presented. T2 - CIM 2023 - 21st International Metrology Congress CY - Lyon, France DA - 07.03.2023 KW - Indoor air quality KW - VOC KW - Materials emissions testing KW - Emission reference material KW - Quality assurance/quality control PY - 2023 AN - OPUS4-57142 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias T1 - Emission reference materials for indoor air measurements N2 - In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. VOC in combination may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. Emission concentrations can become further elevated in new or refurbished buildings where the rate of air exchange with fresh ambient air may be limited due to improved energy saving aspects. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use (building) materials proved to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable emission reference materials (ERM). For the emission test chamber procedure according to EN 16516, no artificial ERM is commercially available. The EU-funded EMPIR project MetrIAQ aims to fill this gap by developing new and improved ERMs. The goal is to obtain a material with a reproducible and temporally constant compound release (less than 10 % variability over 14 days). Two approaches were tested: the impregnation of porous materials with VOC, and the encapsulation of VOC in polymer microcapsules. Impregnation is performed with help of an autoclave and supercritical CO2. The encapsulation is done by interfacial polymerisation on VOC droplets. For both approaches, synthesis and/or material parameters were varied to obtain an optimal ERM. Findings about the optimisation of ERM generation, as well as performance of the best emission reference materials, will be presented. T2 - GAS Analysis 2024 CY - Paris, France DA - 30.01.2024 KW - Emission reference materials KW - Materials emissions test KW - VOC KW - Indoor air quality PY - 2024 AN - OPUS4-59506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rabin, Ira A1 - Hahn, Oliver A1 - Kaska, K. ED - Uhlirz, T1 - Why Do We Need to Study Inks? N2 - While studying the socio-geographic history of inks, division 4.5 (Analysis of cultural artefacts and assets) of the BAM (Bundesanstalt für Materialforschung und -prüfung) in Berlin together with the Centre for the Study of Manuscript Cultures in Hamburg has developed a protocol for ink analysis. It consists of a primary screening to determine the type of the ink, and a subsequent in-depth analysis using several spectroscopic techniques. Using this protocol, scientists can assist scholars in addressing a rather broad range of historical questions that cannot be answered unequivocally through scholarly research alone. Among these are investigations on collaboration between scribes and scriptoria, on the usage and annotation of manuscripts and on their path through time and space in general. This research can thus help to reconstruct the circumstances of the production of written heritage as well as their history and transmission. To facilitate the dialogue between the scholars and the scientists a simple optical tool was developed to allow the scholars to perform preliminary ink analysis required for formulation of the question that in turn can be answered by scientific in-depth investigations. In this paper, ink types and their identification method is accompanied by examples of the recent work conducted on parchment manuscripts in the Austrian National Library. T2 - Congress Visual Heritage, CHNT 23 CY - Vienna, Austria DA - 15.12.2018 KW - Ink KW - Parchment PY - 2020 SP - 1.1 EP - 1.9 CY - Wien AN - OPUS4-50242 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Rabin, Ira A1 - Hahn, Oliver ED - Michel, C. ED - Friedrich, M. T1 - Detection of Fakes: The Merits and Limits of Non-Invasive Materials Analysis N2 - This paper addresses the sensitive issue of authenticating unprovenanced manuscripts of high monetary value to certify they are genuine. Over the last decade, the popularity of material studies of manuscripts using non-destructive testing (NDT) has increased enormously. These studies are held in especially high esteem in the case of suspicious writings due to the methodological rigour they are reputed to contribute to debate. We would like to stress that materials analysis alone cannot prove that an object is genuine. Unfortunately, audiences with a humanities background often tend to disregard the technical details and treat any published interpretation of instrumental analysis as an objective finding. Four examples are outlined here to illustrate what questionable contributions the natural sciences can make in describing manuscripts that have actually been forged. KW - Fakes KW - Non-invasive analysis KW - Limitations PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517202 SN - 978-3-11-071422-7 DO - https://doi.org/10.1515/9783110714333 SN - 2365-9696 VL - 20 SP - 281 EP - 290 PB - Walter de Gruyter GmbH CY - Berlin/Boston AN - OPUS4-51720 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rabin, Ira A1 - Gordon, Nehemia A1 - Cohen, Zina T1 - Inks of the Bologna Scroll: A Preliminary Study N2 - Rotolo 2 at the Biblioteca Universitaria di Bologna, also known simply as the “Bologna Scroll,” is currently the oldest known complete Torah scroll without later replacement sheets or significant lacunae. The Bologna Scroll has some unusual scribal features. According to one opinion in the Babylonian Talmud, a Torah scroll must be written with carbon ink to be valid for liturgical use.12 The main inks of the Bologna Scroll are very black, and the inks of the marginal corrections in tiny letters are even blacker. In this study, eh inks were tested by means of XRF-spectroscopy and NIR imaging. Conreary to the expectations, the current tests have definitively determined that the Bologna Scroll was both written and corrected using multiple iron-gall inks. KW - Torah KW - Ink KW - Historic ink PY - 2024 DO - https://doi.org/10.1353/mns.2024.a945374 VL - 9 IS - 2 SP - 222 EP - 242 AN - OPUS4-62264 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -