TY - CONF A1 - Wilke, Olaf A1 - Poelke, Birte A1 - Klein, Luise A1 - Rohloff, Alexander A1 - Hoffmann, Holger T1 - Initial VOC Emissions from Consumer Products Determined in Micro-Scale Test Chambers: Results of a Round Robin Test N2 - Emissions of volatile organic compounds (VOCs) from consumer products may have a negative impact on indoor air quality, potentially also affecting human wellbeing. Since consumers may be exposed to these VOCs immediately after e.g. unwrapping of newly purchased products, reliable analytical methods are needed to determine air concentration profiles in the early phase of VOC emissions. Concerning typical sample sizes of consumer products, micro-scale test chambers (μ-chambers) were considered suitable for this purpose. In addition, compared to medium- or large-scale test chambers, μ-chambers require lower initial investment and operational costs, and offer options for emissions screenings where higher sample throughput is essential. For these reasons, a μ-chamber-based method to determine initial concentrations of VOCs emitting within the first hours of simulated product use was developed. The chamber air was frequently sampled on desorption tubes loaded with Tenax® TA, followed by quantification of emitted VOCs via thermal desorption gas chromatography mass spectrometry (TD-GC-MS). The method was assessed in a round robin test involving eight participating laboratories from 2 countries. Pieces of a rain poncho (sample area A: 2.01·10-4 m2) emitting cyclohexanone, phenol, 2-ethylhexanol, naphthalene and isophorone in significant concentrations were distributed as sample material. Each laboratory conducted triplicate emission tests over a period of 48 h in μ-chambers with volumes of 44 or 114 mL. The loading factors L of 4.57 m2·m-3 (44 mL) or 1.76 m2·m-3 (114 mL) and air flow rates of 24 mL·min-1 resulted in area-specific air flow rates q of 7.17 m3·m-2·h-1 in both chamber types. The temperature was set to 23°C and, if possible, relative humidity was set to approx. 50%. The chamber air was sampled after 0.5, 1, 2, 4, 24 and 48 hours. In addition, to assess the analytical performance, each participating laboratory received two analyte-spiked Tenax® TA-loaded desorption tubes for quality control (QC). Very low relative standard deviations (11–17%) were obtained for the QC test. The results of the emissions tests in the early phase (0.5–4 h) were also adequate, with acceptable z scores (|z|≤2.00) received by six to seven participating laboratories. All eight laboratories obtained acceptable z scores after the longer sampling periods (24 and 48 h). Hence, the inter-laboratory comparability of the results obtained with the developed μ-chamber method was successfully confirmed. T2 - Healthy Buildings Europe 2025 CY - Reykjavik, Iceland DA - 08.06.2025 KW - VOC Emissions KW - Consumer Product KW - Test Chamber KW - Round Robin Test PY - 2025 AN - OPUS4-63706 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Harmonised test standard EN 16516 - common approach for all building products for interiors N2 - The presentation gives general information about the European Standard EN 16516 “Construction products – Assessment of release of dangerous substances – Determination of emissions into indoor air”. This test standard was developed based on the mandate M/366 of the European commission and is a horizontal reference method for the determination of volatile organic compounds (VOC) from different classes of construction (building) products. Specific test conditions are to be selected by the product TCs (technical committees) in a way that a product is tested under its intended condition of use. The test is based on the use of emission test chambers which are operated at constant air change rate and climate (23°C, 50 % r.h.) over 28 days. The standard defines the conditions and requirements for the measurement including loading factor, air change rate, sampling, analysis and calculation of emission rates of the substances. A 30 m³ reference room is described which is used to calculate air concentrations from the determined emission rates. The standard EN 16516 enables the evaluation of construction products regarding their emissions into indoor air under defined and comparable conditions. The evaluation includes the determination of identified target compounds, non-identified target compounds, volatile carcinogenic compounds and the sum values TVOC, TSVOC and R. T2 - UBA Conference - Limiting health impacts of construction products regarding VOC CY - Online meeting DA - 20.04.2021 KW - Building products KW - EN 16516 KW - Emisson testing KW - Construction products PY - 2021 AN - OPUS4-58079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Contaminants of Emerging Concern from Materials and Products: Measurement and Evaluation N2 - Test chamber measurements are an important tool to improve indoor air quality and occupational safety. Test chamber measurements are possible for a wide range of materials, products and technologies. Determination of concerning contaminants is important to ensure good indoor air quality. The detection of concerning contaminants depends on the approriate sampling and analysis. T2 - Webinar BAM-University of Birmingham CY - Online meeting DA - 24.02.2021 KW - Emerging Contaminants KW - Emission Test Chamber KW - Thermal Extraction KW - Thermal Desorption PY - 2021 AN - OPUS4-52262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -