TY - CONF A1 - Strzelczyk, Rebecca T1 - Constant emitting reference material for emissions test procedures N2 - Since nowadays people spend most of their time indoors, a healthy environment is essential. Volatile organic compounds (VOCs) emitted from furniture and building materials are reported to cause health complaints. Therefore, the usage of low emitting materials will improve the indoor air quality. Quantitative VOC emission testing is usually conducted in emission test chambers under specified controlled conditions as described in DIN 16000-9 and DIN EN 16516. For reasons of quality control/quality assurance (QC/QA) and for a better comparability of test results from different laboratories, suitable emission reference materials (ERM) are needed. Here, it is important to have a homogenous material with known emission rates over a specific time. Different approaches can be found in literature, inter alia polymer films loaded with the target compound to be released again, or a lacquer material to which a VOC mixture is added. After curing of the lacquer, the material can be loaded into a test chamber. Drawback of those approaches are their relatively fast decreasing emission profiles. For QC/QA purposes according to the test standards, VOC sources with constant emission profiles are desirable. The EU-funded research project MetrIAQ “Metrology for the determination of emissions of dangerous substances from building materials into indoor air” is working on a multi-component ERM with an envisaged instability of ≤ 10 % in the emission rate over at least 14 days. Within a doctoral thesis porous materials are impregnated with VOCs. Supercritical CO2 is used as solvent. Thus, the impregnated material does not contain any solvent that may show a measurable amount of emission in the emission test chamber. Furthermore, CO2 has the benefits to have a good availability and low costs. For the selection of porous materials several properties like the pore size, the surface, and the interaction with the components in the atmosphere need to be considered. The impregnation method is optimised while the different porous materials are tested. For the selection of porous materials the pores need to be large enough for the VOC molecules, further influence of the pore size is tested. T2 - Healthy Buildings CY - Aachen, Germany DA - 11.06.2023 KW - VOC KW - Emission KW - Quality assurance KW - Reference material PY - 2023 AN - OPUS4-59842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Wilke, Olaf T1 - Volatile organic compounds from building products - Results from seven proficiency tests with emission test chambers conducted between 2008 and 2021 N2 - Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%. T2 - Proficiency Testing in Analytical Chemistry, Microbiology and Laboratory Medicine CY - Windsor, United Kingdom DA - 25.09.2023 KW - Proficiency Test KW - VOC-Emission KW - Chamber-test PY - 2023 AN - OPUS4-59694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Even, Morgane T1 - Towards an efficient procedure for the analysis of VVOC emissions N2 - This poster summarizes the points that need to be addressed towards the standardization of an efficient procedure for the analysis of VVOC emissions: Standard mixture generation and investigations on mutual reactivity, selection of an appropriate sorbent combination, water management and choice of a suited GC column. T2 - Indoor Air 2020: The 16th conference of the international society of indoor air quality and climate CY - Online meeting DA - 01.11.2020 KW - VVOCs KW - Analytical method KW - ISO 16000-6 KW - EN 16516 PY - 2020 AN - OPUS4-52023 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Müller, Birgit T1 - Low-odour and low-emission indoor products - Nose vers. odour threshold values N2 - To achieve good air quality in buildings, it is necessary to remove, avoid or reduce cleaning loads through ventilation. To reduce the cleaning loads and their effect on the odour perception of the occupants, a sensory test in indoor spaces and on building products is necessary in addition to VOC emission measurements of the contaminants. ISO 16000-28 provides the basis for odour assessment of products using a human olfactory panel. Through many years of experience and testing of these methods, it can now be assumed that reproducible odour ratings are available for many products used indoors. An odour measurement is mandatory for the Blue Angel for carpets and is being tested for environmentally friendly resilient floor coverings. Based on the results of an earlier project and new results of the upcoming study, the ISO should be revised and completed. The project investigates the odour and VOC emissions of building products based on natural raw materials. The data generated is used to address several issues, which are briefly explained below. Floor coverings based on linoleum and rubber are included in the Blue Angel eco-label with an odour assessment. The aim of the project is to clarify whether other assessment methods in addition to intensity can provide better information. Positive hedonics have an influence on the intensity assessment. Typically, building products show high intensity with low hedonic values. Results for wood-based products often show high intensity and positive hedonics. Based on these examples, an appropriate odour assessment of wood-based products for the Blue Angel, supported by research results, should be possible. The concept of the odour guide value which is based on odour threshold values was renewed in 2023. This approach will now be compared with the standardised odour measurement (16000-28). This assessment is based on GC/MS measurements and uses odour thresholds analytically when panel-based odour assessment is not possible. For this procedure well defined odour thresholds are necessary T2 - AIRMON 2025 The 11th International Symposium on Modern Principles of Air Monitoring and Biomonitoring. CY - Loen, Norway DA - 15.06.2025 KW - Emission KW - Indoor air quality KW - Materials emissions test KW - VOC KW - Geruch PY - 2025 UR - https://stami.no/en/wp-content/uploads/sites/2/2025/06/Programhefte-Airmon-2025-Juni-10-YTH.pdf AN - OPUS4-63634 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Klein, Luise A1 - Bethke, Robert T1 - Determination of uptake rates of VVOCs and carbonyls in indoor air on passive sampling system N2 - The identity and concentration of volatile contaminants are important factors in ensuring a healthy indoor environment. Volatile organic compounds (VOCs) in indoor air can be determined by using passive samplers that are exposed to the air for a well-defined period of time. This sampling method is often used in environmental surveys, e.g. the German Environmental Survey (GerES). Conclusions about indoor air concentrations can be drawn from substance and adsorption material specific uptake rates. For the assessment of indoor air quality, highly volatile organic compounds may also be substantial, but for many of these substances realistic uptake rates and suitable analytical methods are lacking. A small chamber is used to generate gas atmospheres with constant concentrations of the analytes at 23 °C and 50 % relative humidity. For a large number of compounds, a very small flow of pure liquid VVOCs is introduced into the chamber via a syringe pump and mixed with a constant flow of clean and humidified air. A gas mixture from cylinders is also used for this purpose. Carbograph 5TD has already been proven as a suitable sorption material for active sampling for most of VVOCs. With this procedure up to 55 different VVOCs should be tested in this study. Stable concentrations of gas phase atmospheres of the first group of VVOCs (acetone, 2-butanone, methyl acrylate) were produced for exposure of passive samplers. Comparison of different adsorbent materials showed that Carbograph 5TD was the most suitable for passive sampling of these substances, with higher uptake than Carbopack X and Tenax® TA. Very strong adsorbents are not suitable for this experimental design as it adsorbs larger amounts of water. The effective uptake rates were calculated for the first three VVOCs on Carbograph 5TD tubes and an exposure time of 7 days. The same experiment will be performed for all VVOCs and ideally one material should be the best option for all of them. T2 - AIRMON 2025 The 11th International Symposium on Modern Principles of Air Monitoring and Biomonitoring. CY - Loen, Norway DA - 15.06.2025 KW - VVOC KW - Air quality KW - Passive sampling PY - 2025 UR - https://stami.no/en/wp-content/uploads/sites/2/2025/06/Programhefte-Airmon-2025-Juni-10-YTH.pdf AN - OPUS4-63632 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bonnerot, Olivier T1 - XRF Ink analysis of selected fragments from the Herculaneum collection N2 - Hundreds of papyrus rolls, carbonized during the 79CE eruption of Mount Vesuvius, were discovered in 1754 at Herculaneum. Sophisticated mechanical methods for unrolling the best-preserved scrolls have been applied, with varying success. However, such processes have been abandoned, to prevent risk from irremediable damage or loss and to preserve the integrity of the extremely fragile rolls. Following the development of X-ray based non-invasive techniques, attempts to virtually unroll the scrolls were made. The most common ink in Antiquity was carbon-based, and the main element of carbonized papyrus is carbon, making these investigations difficult. However, some attempts with synchrotron X-ray phase-contrast tomography (XPCT) were successful. Recently, the identification of antique inks containing metals raised hope that if some of the inks contain metal the rolls can be virtually unrolled using conventional CT- technique. We investigated the inks of a selection of partially unrolled fragments stored at the Biblioteca Nazionale di Napoli with X-ray fluorescence in order to select the best candidates for tomography. Despite the many difficulties (analysis of several layers sticking together, letters barely visible, difficulty to separate contribution from the ink and from the papyrus, inhomogeneity of the support, fragility of the fragments…), encouraging results were found, with a number of inks from Greek fragments found to contain additions to the soot (Fe, Pb, Cu P). T2 - International Symposium on Archaeometry CY - Online meeting DA - 16.05.2022 KW - XRF KW - Ink KW - Herculaneum KW - Papyrus PY - 2022 AN - OPUS4-54892 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Abilio, André T1 - Expert System for Screening Microbiologically Influenced Corrosion (MIC) as Internal Failure Cause in Oil and Gas Upstream Pipelines N2 - The analysis of pipeline failures due to Microbiologically Influenced Corrosion (MIC) is challenging due to the complex interaction of many influencing parameters including pipeline operation conditions, fluid chemistry and microbiology, as well as the analysis of corrosion features and products. To help address this challenge, an expert system was developed to assist non-specialists in screening internal pipeline corrosion failures due to MIC related threats. To accomplish this, 15 MIC subject matter experts (with a total of 355 man-years of accumulated MIC based experience) were recruited to evaluate a total of 65 MIC failure cases based on real-life scenarios. These case study parameters and the expert elicited results were input into an Artificial Neural Network (ANN) model to create a model system which can screen whether a given failure scenario is one of three outcomes: a) failure is likely due to MIC, b) failure is likely not due to MIC, or c) the conclusion is inconclusive (analysis needs more data/information). The model system had an overall accuracy of 74.8% and it showcases that knowledge from subject matter experts can be captured in a reasonably effective way to screen for possible MIC failures. Based on that, this presentation will provide details of the model development process and key results to date. Important considerations regarding the level of confidence of the diagnoses and variation between expert opinion will also be discussed alongside with ideas on how to improve the model for field applicability. T2 - ISMOS 9 CY - Edinburgh, United Kingdom DA - 27.06.2023 KW - Expert System KW - Microbiologically Influenced Corrosion (MIC) KW - Oil and Gas Upstream KW - Failure Investigation KW - Artificial neural networks (ANN) PY - 2023 AN - OPUS4-64603 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Piechotta, Christian T1 - Development, Validation and Application of an Accelerated Weathering Protocol for Assessing Bisphenol A Release from Polycarbonate Materials into the environment N2 - Bisphenol A (BPA) is under continuous regulatory scrutiny and listed as substance of very high concern (SVHC). Particular concern is related to its frequent detection in surface waters, despite being readily biodegradable. Several studies have been conducted to investigate sources and pathways of BPA in the environment, concluding that its main use as monomer in polycarbonate (PC) contributes only marginally to environmental BPA releases over its life cycle. To better understand the actual releases of BPA from PC under environmental conditions, a newly developed methodology (Federal Institute for Materials Research and Testing, BAM) was applied, which comprises a novel accelerated weathering protocol for polycarbonate (PC) materials, combined with an advanced analytical setup allowing for improved detection of BPA at trace level concentrations. The weathering protocol achieves a 13.6-fold acceleration compared to Central European outdoor conditions and simulates environmental stressors (global radiation, rain, temperature variations) in a laboratory weathering chamber, with simultaneous BPA release measurements using an organic isotope dilution calibration LC-MS/MS approach. Validation was performed in parallel outdoor exposure tests, by using haze and yellowness index measurements as reference parameters. PC sample types representative of major polycarbonate applications were examined: Samples with different levels of UV-protection as used in transparent sheets used outdoor in construction or housings in Electro- and Electronic applications as well as samples with a protective coating as used in automotive applications (headlamps, glazing and construction). Results demonstrated consistently low total BPA releases of around 0.3 mg m⁻² for samples with exposed PC surfaces, while releases from coated samples were significantly reduced by around two orders of magnitude. In all cases examined, the BPA release ceased to zero after a period of four to six weeks, equivalent to approximately 1 to 1.5 years of outdoor exposure. This suggests that potential BPA releases diminish to virtually zero after that timespan. While the newly developed test method is not suitable for routine laboratory implementation, it provides crucial quantitative data on BPA release from PC materials during accelerated environmental weathering. T2 - Umwelt 2025 CY - Dessau, Germany DA - 22.09.2025 KW - Bisphenol A KW - Polycarbonate KW - Weathering PY - 2025 AN - OPUS4-64665 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braymer, Joseph T1 - Methanobacterium IM1 as a model organism to study MIC N2 - Microbiologically influenced corrosion (MIC), also known as biocorrosion, is a process where microbes corrode metal surfaces causing detrimental damage to manmade infrastructure. Several studies, mainly under anaerobic conditions, have identified sulfate-reducing bacteria and methanogens as key players in biocorrosion. However, an important issue is that most MIC-related microbes at the moment are non-culturable. In addition, improved technologies (i.e., omics, biochemical, and microscopy methods) are needed to study, detect, simulate, and modulate MIC-related cases. Therefore, the selection of strains that can cause MIC, are culturable, and are genetically accessible, are of high importance for establishing new methods to study MIC on the molecular level. For example, the archaeal strain Methanobacterium IM1 has caught great attention due to its involvement in biocorrosion processes. Genes encoding for a novel enzyme (MIC NiFe-hydrogenase) have been proposed in this methanogen to be directly related to the e T2 - International Biodeterioration and Biodegradation Symposium 19 CY - Berlin, Germany DA - 11.09.2024 KW - Biocorrosion KW - Methanogen KW - Iron KW - Hydrogenase KW - Mechanism PY - 2024 AN - OPUS4-61508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Koerdt, Andrea T1 - Simulating Microbiologically Influenced Corrosion (MIC) at Seabed Environment in Monopile N2 - Ensuring the safety of offshore wind structures (OWS) is critical to guaranteeing their long-term performance and supporting reliable green energy supply. Microbiologically influenced corrosion (MIC) presents a significant challenge, particularly for monopiles in seabed environments. This study investigates the behavior of microorganisms and their impact on the corrosion process of carbon steel within monopiles. To simulate MIC at the sediment/water interface, an in-house experimental column was developed and inoculated with sediment and water samples from the North Sea. The system was operated under varying flow rates to replicate seabed movement conditions. Multiple molecular microbiological methods, surface analysis techniques, and other approaches were employed to assess the effects of different treatments. This study provides insights into MIC mechanisms in offshore environments and supports the development of strategies to monitor MIC in OWS infrastructure T2 - ISMOS10 CY - Nashville, TN, USA DA - 11.08.2025 KW - MIC KW - Environmental Simulation KW - Field testing KW - Marine Environment PY - 2025 AN - OPUS4-64298 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -