TY - JOUR A1 - Schreiner, V. C. A1 - Fernandez, D. A1 - Vermeirssen, E. L. M. A1 - Bandow, Nicole A1 - Munoz, K. A1 - Schäfer, R. B. T1 - Corrigendum to “Calibration and field application of passive sampling for episodic exposure to polar organic pesticides in streams” [Environ. Pollut. 194 (2014) 196-202] N2 - The authors regret that the sampling rates were miscalculated as a result of flaws in the R script. Using a R script algorithm (Schreiner et al., 2020) sampling rates changed up to 45% (Table 1). KW - Passive sampling KW - Pesticides PY - 2020 DO - https://doi.org/10.1016/j.envpol.2020.115335 SN - 0269-7491 VL - 265 IS - Part B SP - 115335 EP - 115335 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-51227 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kalbe, Ute A1 - Piechotta, Christian A1 - Bandow, Nicole T1 - Comparing PFAS analysis in batch leaching and column leaching tests N2 - Laboratory leaching tests are tools to assess the mobility of environmental contaminants released from granular materials. Comparative leaching tests were performed using four PFAS-contaminated soils whose concentration patterns of 10 selected perfluoroalkyl and polyfluoroalkyl substances (PFAS) differed due to the two types of contamination sources. This study aimed to evaluate the equivalence of two usual laboratory-scale leaching test procedures, batch and column percolation tests, at liquid-to-solid ratios (L/S) of 2 l/kg, which is the current practice within the German assessment framework, and 10 l/kg (relevant for some EU regulations such as the landfill directive). The differences between the replicates of leaching tests investigating PFAS were smaller for column percolation tests than for batch tests, probably mainly due to the greater sample size and the better representativeness of the sample portion analyzed. It was observed that batch tests overestimate the release of shorter-chain PFAS, whereby the effect was greater with carboxylic than with sulfonic acids. Currently, the limits of detection of analyses given by the DIN standard with regard to PFCA and PFSA in soils are partly not sufficient to detect very low contents, whereas the detection of selected PFCA and PFSA in eluates is more sensitive, in accordance with the available standards. This results in limitations when calculating mass balances. KW - PFAS KW - Leaching KW - Column percolation test KW - Batch test KW - Soil PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-618187 DO - https://doi.org/10.1007/s11356-024-35510-0 SN - 1614-7499 VL - 31 IS - 57 SP - 65233 EP - 65251 PB - Springer Science and Business Media LLC AN - OPUS4-61818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -