TY - CONF A1 - Wille, Frank A1 - Moutarde, M. A1 - Apel, Andreas A1 - Nehrig, Marko T1 - Revision of IAEA Guidance Material for Package Load Attachment Points N2 - For transport operations according IAEA regulations SSR-6, the package shall be securely stowed and the package shall be capable to withstand specific effects, e.g. accelerations, during routine transport conditions. The supporting IAEA Advisory Material SSG-26 provides information how to do that. General information and detailed load factors for use in safety demonstrations are provided. Up to now package designers in different countries use other load factors for the design of attachment points than those specified in the IAEA guidance material. In particular the acceleration factors vary between different countries and lead to difficulties during the validation of foreign approval certificates. The background of the existing guidance including specified load values was not clear enough. The application of specified values and the boundary conditions, i.e. transport conditions, seemed to be improvable. The IAEA started a discussion process to review the existing guidance text. An international working group was constituted in 2013. Representatives came from different stakeholders, e.g. transport operators, competent authorities and modal organizations. The discussions concluded especially on the transport conditions which has to be considered for stowage design, including on the one hand the relevance of the load factors used for strength and fatigue analysis and, on the other hand the criteria which have to be considered for the attachment points. In addition, complementary questions relative to the operational aspects were discussed. Revised load values for different transport modes were proposed. The values are derived from standards and include safety factors now. As a result of those discussions, the international working group wrote new guidance material for stowage in transport, addressing all the previously quoted topics. T2 - WM2018 Conference CY - Phoenix, Arizona, USA DA - 18.03.2018 KW - Acceleration values KW - IAEA regulations KW - Routine conditions of transport PY - 2018 AN - OPUS4-44866 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rolle, Annette A1 - Ballheimer, Viktor A1 - Neumeyer, Tino A1 - Wille, Frank T1 - Application of leakage rates measured on scaled cask or component models to the package containment safety assessment N2 - The mechanical and thermal loadings associated with the routine, normal and accident conditions of transport can have a significant effect on the leak tightness of the containment system of transport casks for spent fuel and high radioactive waste. The containment systems of such transport casks usually include bolted lids with metallic or elastomeric seals. Scaled cask models are often used for providing the required mechanical and thermal tests series. Leak tests have been conducted on those models. It is common practice to use scaled component tests to investigate the influence of deformations or displacements of the lids and the seals on the standard leakage rate as well as to study the temperature and time depending alteration of the seals. In this paper questions and open points of the transferability of scaled test results to the fullscale design of the containment system will be discussed. T2 - 11th International Conference on the Transport, Storage and Disposal of Radioactive Materials CY - London, UK DA - 15. Mai 2018 KW - Transport packages KW - Radioactve KW - Seals KW - Leakage rate PY - 2018 AN - OPUS4-46734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rolle, Annette A1 - Neumeyer, Tino A1 - Ballheimer, Viktor A1 - Wille, Frank T1 - Investigations of Aged Metal Seals for Transport Package Safety Assessment N2 - Acceptable limits for activity release from transport casks for high-level radioactive material specified in the IAEA regulations must be kept by the integrity of cask body and the cask sealing system. BAM as the German competent authority for mechanical, thermal and containment assessment of packages liable for approval verifies the activity release compliance with the regulatory limits. The specification of conservative package design leakage rates is one of the most important aspects in assessment. Metal seals of the Helicoflex® Type are usually used to ensure the required package tightness for both, storage, and transport of the cask before and after storage. Due to the long-term use the seal behavior is influenced by temperature and time. The mechanical and thermal loadings associated with the routine, normal and accident conditions of transport specified in the regulations can have a significant effect on the leak tightness of the sealing system. Whereas the safety for application of new, non- aged Helicoflex® seals is verified sufficiently, there are still technical data gaps concerning the efficiency of aged Helicoflex® seals. BAM performed experiments to learn more about the sealing efficiency of aged Helicoflex® seals with Aluminum and Silver outer jackets. The seals were compressed in test-flanges and for artificial ageing the complete flange systems were stored in an oven for several month at a high temperature. After this ageing procedure the flanges were opened completely, the seals were moved a little to vary the contact area, and the flanges were compressed again. During the compression and decompression tests after the aging, load-deformation characteristics of the seals, and leakage rates were measured. With these tests a load situation was simulated, which can occur in the regulatory drop test of the cask: Under high impact loads the bolted lid can lift a little for a short moment, allowing a little movement of the seal, so that the contact area can change before compressing again. Details about test conditions and first results will be presented in the poster. T2 - RAMTrans 2024, 12th Internatiopnal Conference on the Transport , Storage and Disposal of Radioactive Materials CY - London, UK DA - 15.05.2024 KW - Seals KW - Ageing KW - Radioaktiv PY - 2024 AN - OPUS4-60112 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rolle, Annette A1 - Neumeyer, Tino A1 - Ballheimer, Viktor A1 - Wille, Frank T1 - Investigations of Aged Metal Seals for Transport Package Safety Assessment N2 - Acceptable limits for activity release from transport casks for high-level radioactive material specified in the IAEA regulations must be kept by the integrity of cask body and the cask sealing system. BAM as the German competent authority for mechanical, thermal and containment assessment of packages liable for approval verifies the activity release compliance with the regulatory limits. One of the fundamental aspects in assessment is the specification of conservative package design leakage rates. To ensure the required package tightness for both, storage, and transport of the cask before and after storage usually metal seals of the Helicoflex® Type are used. Due to the long-term use the seal behavior is influenced by temperature and time. The mechanical and thermal loadings associated with the routine, normal and accident conditions of transport specified in the regulations can have a significant effect on the leak tightness of the sealing system. Whereas the safety for application of new, non- aged Helicoflex® seals is verified sufficiently, there are still technical data gaps concerning the efficiency of aged Helicoflex® seals. BAM performed experiments to learn more about the sealing efficiency of aged Helicoflex® seals with Aluminum and Silver outer jackets. The seals were compressed in test-flanges and for artificial ageing the complete flange systems were stored in an oven for several month at a high temperature. During the compression and decompression tests after the aging, load-deformation characteristics of the seals, and leakage rates were measured. With these tests a load situation was simulated, which can occur in the regulatory drop test of the cask: Under high impact loads the bolted lid can lift a little for a short moment, allowing a little movement of the seal, so that the contact area can change before compressing again. The poster presentation will show details about test conditions and first results. T2 - Interdisciplinary research symposium on the safety of nuclear disposal practices safeND2023 CY - Berlin, Germany DA - 13.09.2023 KW - Radioactive material KW - Sealing KW - Ageing KW - Leaktightnes PY - 2023 AN - OPUS4-58436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -