TY - CONF A1 - Amano, K.O.A. A1 - Hahn, S.-K. A1 - Tschirschwitz, Rico A1 - Rappsilber, Tim A1 - Krause, U. T1 - Experimental Investigation on Explosion Pressure Characteristics of Lithium-based (NMC) Pouch Batteries during Thermal Runaway N2 - Lithium ion batteries (LIBs) are prone to spontaneous and subsequent fire or explosion resulting from thermal runaway. The vented gases are not only toxic and flammable, their emission can also raise the surrounding pressure rapidly. In this study, characteristic variations of explosion pressure rise, rate of explosion pressure rise and 𝐾(sT)-value have been evaluated. The characteristic 𝐾(𝑠𝑇)-values were determined to evaluate the explosive behavior of LIBs during thermal runaway. The estimated values were compared to that of other explosive substances. T2 - Batterieforum Deutschland 2021 CY - Online meeting DA - 20.01.2021 KW - Pressure KW - Lithium KW - Thermal Runaway KW - Battery KW - Pouch PY - 2021 AN - OPUS4-52033 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Aris, Stephan T1 - Neue Informationen und Erfahrungsaustausch zu in Feuerlöschern verwendeten ortsbeweglichen Druckgeräten N2 - Im Vortrag werden die aktuellen Anforderungen an die Beförderung von Feuerlöschern UN 1044 und an in tragbaren/fahrbaren Feuerlöschern verwendete Treibgasflaschen vorgestellt. Es wird auf die damit verbundenen praktischen Probleme sowie aktuelle Lösungsansätze eingegangen. T2 - Fortbildung GRIF CY - Prichsenstadt, Germany DA - 07.09.2021 KW - ADR KW - Ortsbewegliche Druckgeräte KW - TPED KW - Tragbare Feuerlöscher KW - Treibgasflaschen PY - 2021 AN - OPUS4-53265 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Xie, Y. A1 - Cui, Y. A1 - Wu, Dejian A1 - Zeng, Y. A1 - Sun, L. T1 - Economic analysis of hydrogen-powered data center N2 - The data center needs more and more electricity due to the explosive growth of IT servers and it could cause electricity power shortage and huge carbon emission. It is an attractive and promising solution to power the data center with hydrogen energy source. The present work aims to conduct an economic analysis on the hydrogen-powered data center. Configurations of hydrogen-powered and traditional data centers are compared and the differences focus on backup power system, converter/inverter, fuel cell subsystem, carbon emission, hydrogen and electricity consumptions. Economic analysis is conducted to evaluate the feasibility to power the data center with hydrogen energy source. Results show that electricity price increasing rate and hydrogen cost are the main factors to influence economic feasibility of hydrogen-powered data center. When the electricity price keeps constant in the coming two decades, the critical hydrogen price is about 2.8 U.S. dollar per kilogram. If the electricity price could increase 5% annually due to explosive growth of electric vehicles and economy, critical hydrogen price will become 6.4 U.S. dollar per kilogram. Hydrogen sources and transportation determine the hydrogen price together. Hydrogen production cost varies greatly with hydrogen sources and production technologies. Hydrogen transport cost is greatly influenced by distances and H2 consumptions to consumers. It could be summarized that the hydrogen-powered data center is economic if hydrogen could be produced from natural gas or H2-rich industrial waste streams in chemical plant and data center could not be built too far away from hydrogen sources. In addition, large-scale hydrogen-powered data center is more likely to be economic. Solar hydrogen powered data center has entered into a critical stage in the economic feasibility. Solar hydrogen production cost has restrained the H2 utilization in data center power systems now, since it could be competitive only when more strict carbon emission regulation is employed, hydrogen production cost reduces greatly and electricity price is increasing greatly in the future. However, it could be expected solar hydrogen-powered system will be adopted as the power source of data centers in the next few years. KW - Hydrogen KW - Date center KW - Economic analysis PY - 2021 DO - https://doi.org/10.1016/j.ijhydene.2021.06.048 SN - 0360-3199 VL - 46 IS - 55 SP - 27841 EP - 27850 PB - Elsevier Ltd. AN - OPUS4-53658 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zang, N. A1 - Qian, X. A1 - Shu, C. A1 - Wu, Dejian T1 - Parametric sensitivity analysis for thermal runaway in semi-batch reactors: Application to cyclohexanone peroxide reactions N2 - The semi-batch reactors (SBRs) system, which is widely used in industrial processes, possesses an intrinsic parametric sensitivity, in which infinitesimal disturbances of input parameters can result in large variations in output variables. In this work, local parametric sensitivity analysis (PSA) was used to understand parameter variations and global PSA was conducted to examine the interaction of input parameters. The effects of these parameters on the output of the system model were analyzed based on the Monte Carlo method with Latin hypercube sampling and the extended Fourier amplitude sensitivity test model. The results showed that the evolution of thermal behaviors in SBRs were observed: marginal ignition; thermal runaway; and the quick onset, fair conversion, and smooth temperature profile. The threshold point of transition from marginal ignition to thermal runaway was at the maximal value of local sensitivity, for which the slope with respect to cooling temperature equaled zero. Moreover, the sequence of the global sensitivity of six common input parameters was computed and evaluated. The reliability of the numerical models was verified by using our previous experimental results of cyclohexanone peroxide reaction. This comprehensive sensitivity analysis could provide valuable operating information to improve chemical process safety. KW - Semi-batch reactor KW - Parametric sensitivity analysis KW - Monte Carlo method KW - Thermal runaway KW - Cyclohexanone peroxide PY - 2021 DO - https://doi.org/10.1016/j.jlp.2021.104436 SN - 0950-4230 VL - 70 SP - 104436 PB - Elsevier Ltd. AN - OPUS4-53659 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wang, D. A1 - Ji, T. A1 - Jing, Q. A1 - He, W. A1 - Fan, Z. A1 - Wu, Dejian A1 - Qian, X. T1 - Experimental study and mechanism model on the ignition sensitivity of typical organic dust clouds in O2/N2, O2/Ar and O2/CO2 atmospheres N2 - To reveal and improve our understanding of the ignition behavior and mechanism, G-G furnace experiments of three typical organic dusts were performed to investigate the minimum ignition temperature (MIT) in O2/N2, O2/ Ar and O2/CO2 atmospheres with oxygen mole fraction from 8.4% to 50%. The experimental results were presented in oxygen-lean and oxy-fuel atmospheres to evaluate the ignition sensitivity of dusts in different atmospheres. It was found that CO2 is the strongest in terms of lowing the ignition sensitivity of the three dusts, and the dust explosion risk increases significantly with increasing O2 mole fraction for the three dusts through a logarithmically and significantly reducing MIT. However, for different dusts, inert gases show different suppression effects. In addition, a modified steady-state homogeneous ignition model was proposed and successfully applied to oxygen-lean atmospheres, and in oxy-fuel atmospheres, this model has also been improved to estimate the ignition mechanism. This ignition mechanism model could be used to successfully predict the minimum ignition temperature of high volatile dust under different inert atmospheres controlled by homogeneous ignition, which will provide a reference for the ignition hazard assessment of dust on hot surfaces. KW - Dust explosions KW - Gas explosions KW - Minimum ignition temperature KW - Hybrid mixtures PY - 2021 DO - https://doi.org/10.1016/j.jhazmat.2021.125108 SN - 0304-3894 VL - 412 SP - 125108 PB - Elsevier B.V. AN - OPUS4-53660 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, Z. A1 - Guo, X. A1 - Xie, G. A1 - Yan, T. A1 - Wu, Dejian A1 - Zhang, F. A1 - Ang, R. T1 - Heat and electric flux coupling of closed-loop thermoelectric generator N2 - Thermoelectric generator (TEG) has been proved as a promising technology for directly converting heat into electricity based on Seebeck effect. On the contrary, this electricity can trigger a solid-state cooling based on conventional Peltier effect. However, these two effects induce a coupling between heat and electric flux, especially for the quantitative relationship still remaining a mystery. Here, we show experimental evidence and theoretical calculation for the coupling by monitoring transient response of fluid temperature and output power. The experimental maximum heat flow in open circuit is 1162 W at cold fluid flow rate = 0.3 m3/h and fluid temperature difference ΔTf = 70 °C, enhanced by 13% owing to heat compensation from intrinsic coupling in closed-loop circuit. Meanwhile, the measured maximum output power of TEG is 18.2 W, and subsequently decreases to 15.4 W due to the objective existence of coupling. This double-edged sword in coupling vigorously inspires the potential applications in heat-dissipation situation such as spacecraft, electronic components, photovoltaic, refrigerator and etc. Present findings open a novel avenue for manipulating heat-electricity conversion in practical engineering. KW - Thermoelectric generator PY - 2021 DO - https://doi.org/10.1016/j.enconman.2021.114529 SN - 0196-8904 VL - 244 SP - 1 EP - 13 PB - Elsevier Ltd. AN - OPUS4-53661 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, W. A1 - Wei, A. A1 - Huang, W. A1 - Zhao, Peng A1 - Schmidt, Martin A1 - Krause, Ulrich A1 - Wu, Dejian T1 - Experimental and theoretical study on the inhibition effect of CO2/N2 blends on the ignition behavior of carbonaceous dust clouds N2 - Gaseous inhibitors are used in many industries for the explosion prevention of combustible dusts, mitigating the potential hazard to humans, properties and environments. This work experimentally and theoretically studied the inerting effect of gaseous inhibitors on the ignition process of dust clouds in O2/N2/CO2 atmospheres, with an emphasis on the role of the CO2/N2 ratio. 10 different combustible carbonaceous dusts were selected, including grain dust, biomass dust and coal dust. Experimental results showed that the inhibition effect of CO2/N2 is closely related to the ignition mechanism of dust clouds. Specifically, a higher ratio of CO2/N2 yields a stronger inhibition effect on the ignition process of dust samples with relatively low volatile matter contents predominated by heterogeneous ignition. In addition, two novel steady-state ignition mechanism models were developed to interpret the experimental observations. Maxwell-Stefan equations were used to describe the diffusivity in the ternary O2/N2/CO2 gas mixtures. The analytical results were in good agreement with the experimental data of the minimum ignition temperature of dust cloud (MITC) in oxygen-lean atmospheres. The mechanism modelling can be used to estimate the critical ignition temperature of all carbonaceous dust clouds with a wide range of volatile matter content under different inert atmospheres, which will provide a reference for the explosion hazard assessment of dust posed by a hot surface in the process industries. KW - CO2/N2 ratio KW - Inerting effect KW - Volatile matter content KW - MITC KW - Mechanism model PY - 2021 DO - https://doi.org/10.1016/j.psep.2021.07.005 SN - 0957-5820 VL - 153 SP - 1 EP - 10 PB - Elsevier B.V. AN - OPUS4-53662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Anja A1 - Krentel, Daniel A1 - Patzelt, Anne-Katrin T1 - InnoBOSK - Neues Netzwerk für besser abgestimmte zivile Sicherheitstechnik N2 - Innovative Lösungen im Bereich der zivilen Sicherheitstechnologie müssen sehr genau auf die Ansprüche der Endanwender*innen abgestimmt werden. Das vom Bundesministerium für Bildung und Forschung (BMBF) geförderte Innovationsforum InnoBOSK der Bundesanstalt für Materialforschung und -prüfung (BAM) ermöglicht erstmalig die Vernetzung von Behörden und Organisationen mit Sicherheitsaufgaben (BOS) mit kleinen und mittleren Unternehmen (KMU). Während verschiedener Workshops, einer zweitägigen Konferenz und auf der digitalen Plattform des Projekts können Anbieter*innen und Endanwender*innen technischer Ausstattung in der zivilen Gefahrenabwehr in Kontakt treten. KW - BOS KW - KMU KW - Netzwerk KW - Security KW - Safety PY - 2021 SN - 0948-7913 VL - 52 IS - 2/2021 SP - 35 EP - 38 PB - Walhalla Fachverlag CY - Regensburg AN - OPUS4-53594 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wiesner, Anja A1 - Neumann, Patrick P. A1 - Krentel, Daniel A1 - Patzelt, Anne-Katrin T1 - Übersicht IFAFRI Capability Gaps N2 - Die zehn Capability Gaps der IFAFRI (International Forum to Advance First Responder Innovation) werden zusammengefasst und übersichtlich dargestellt. KW - BOS KW - KMU KW - IFAFRI KW - Security KW - Safety PY - 2021 SP - 1 EP - 10 CY - Berlin AN - OPUS4-53624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kolbe, Matthias T1 - Untersuchungen zur Explosivbearbeitung von Bauteilen in Schiffsmotoren N2 - Vorstellung des Plattierens von Metallen mit Hilfe von Explosivstoffen. T2 - 42. Informationstagung Sprengtechnik CY - Siegen, Germany DA - 15.10.2021 KW - Explosivstoffe KW - Sprengplattieren KW - TTS PY - 2021 AN - OPUS4-53632 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -