TY - CONF A1 - Rurack, Knut T1 - Advanced Onsite Analysis for Point-of-Need Applications: Innovations for Robust, Reliable, and User-Friendly Detection N2 - The advancement of portable analytical assays has transformed onsite analysis in several areas, including food safety, environmental monitoring and forensics. The SARS-CoV-2 pandemic has fueled a need for rapid, onsite solutions that enable immediate decision making without the need for and use of laboratory infrastructure. The integration of mobile devices with advanced cameras and significant computing power improves the accessibility and usability of these tests. However, many current methods are limited to the detection of single parameters. The next challenge is to develop robust multiplexed assays that can analyze multiple parameters simultaneously with high sensitivity. In this lecture, innovative approaches developed at BAM will be presented with a focus on supramolecular chemistry, luminescence detection, nanomaterials and miniaturization of devices. Examples will include mesoporous nanomaterials, gated indicator systems, imprinted polymers, microfluidic devices, test strips and smartphone-based analytical tools, focusing on two use cases, i.e., the detection of contaminants in surface waters and immunoanalytical explosives detection. T2 - International Conference on Emergin Trends in Materials Chemistry CY - Coimbatore, India DA - 03.04.2025 KW - Onsite analysis KW - Rapid tests KW - Mobile devices KW - Supramolecular chemistry KW - Fluorescence PY - 2025 AN - OPUS4-65434 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Prakash, Swayam A1 - Bell, Jérémy A1 - Rurack, Knut T1 - Rapid Onsite Detection of Fecal Contamination in Water Using a Portable Fluorometric Assay N2 - Fecal pollution in water poses significant health risks, especially when contaminated sources are used for drinking and food production. Traditional water quality testing methods are expensive, slow, and require skilled personnel, limiting their accessibility. This work addresses these issues by developing a portable fluorometric assay for the detection of the fecal indicator pigment urobilin (UB). The assay uses silane-functionalized glass fiber strips impregnated with zinc chloride, providing a ‘drop-&-detect’ approach with enhanced fluorescence response mediated by the unique complexation properties of ZnCl2 and UB. This approach allows for the detection of UB at sub-nanomolar concentrations in less than 1 min using a 3D-printed setup with miniaturized optical components powered by a smartphone with its camera as a detector. The results validated with a benchtop fluorometer show the effectiveness of this method. The successful application of this userfriendly, rapid, and sensitive assay to real water samples from three rivers and the influx and efflux of a wastewater treatment plant advances field-based water quality monitoring, meets the WHO’s ASSURED criteria, and supports progress toward the global clean water and sanitation goals. KW - Fecal pigment KW - Fluorescence KW - Signal amplification KW - Surface chemistry KW - Water quality testing PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-655543 DO - https://doi.org/10.1021/acssensors.5c03922 SN - 2379-3694 VL - 11 SP - 1 EP - 9 PB - American Chemical Society CY - Washington, D.C. AN - OPUS4-65554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hernández-García, María Amparo A1 - Rurack, Knut A1 - Bell, Jérémy T1 - Rapid fabrication of optical elements for sensing applications using a standard SLA printer N2 - The demand for compact, high-performance optical components has driven the development of increasingly sophisticated and miniaturized optical elements, often requiring complex and costly fabrication methods. In this study, we propose a cost-effective and accessible methodology for the fabrication of lenses and free-form optics using a commercially available stereolithography (SLA) 3D printer. A systematic characterisation of six transparent photopolymer resins was conducted in terms of their spectroscopic, optical, and morphological properties, i.e., surface and dimensional properties. The evaluation encompassed parameters such as transmittance, autofluorescence, refractive index, and surface roughness. A straightforward yet resilient printing and post-treatment protocol was formulated, facilitating the fabrication of optical components with over 80% transmittance, minimal intrinsic fluorescence, and surface quality that is compatible with exacting optical applications. The fabricated components demonstrated excellent dimensional fidelity to digital designs and high reproducibility. To demonstrate the versatility of this approach, aspherical, miniaturized, and freeform lenses were designed and integrated into three fluorogenic sensing systems, including oil (strip-based) and chlorine (microfluidic-based) detection platforms, as well as a smartphone-based SARS-CoV-2 biosensor. The integration of customized 3D-printed optics has been demonstrated to enhance signal collection and readout performance, thereby highlighting the potential of this approach to democratize the rapid prototyping and deployment of miniaturized optical systems. This work represents a significant advancement in the field of additive manufacturing, particularly in relation to the development of functional photonic devices. Furthermore, it opens new prospects for sensor applications in biosensing, microfluidics, imaging, and integrated optics. KW - 3D-printing KW - Free-form KW - Prototyping KW - Optical resin KW - Surface finishing KW - Fluorescence KW - Sensor PY - 2026 DO - https://doi.org/10.37188/lam.2026.024 VL - 7 SP - 1 EP - 19 PB - Light Publishing Group CY - Changchun AN - OPUS4-65555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Costa, Elena A1 - Climent Terol, Estela A1 - Ast, S. A1 - Weller, Michael G. A1 - Canning, J. A1 - Rurack, Knut T1 - Development of a lateral flow test for rapid pyrethroid detection using antibody-gated indicator-releasing hybrid materials N2 - The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use. Antibody-gated indicator-releasing materials were thus developed and implemented with test strips for lateral-flow assay-based analysis employing a smartphone for readout. Besides a proper matching of pore sizes and gating macromolecules, the functionalization of both the material's outer surface as well as the strips with PEG chains enhanced system performance. This simple assay allowed for the detection of permethrin as a target molecule at concentrations down to the lower ppb level in less than 5 minutes. KW - Lateral flow test KW - Gated hybrid material KW - Fluorescence KW - Smartphone readout device KW - Pyrethroid KW - Pesticide KW - Insecticide KW - SBA-15 KW - Permethrin PY - 2020 DO - https://doi.org/10.1039/d0an00319k SN - 0003-2654 SN - 1364-5528 VL - 145 IS - 10 SP - 3490 EP - 3494 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-50756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hernández García, María Amparo T1 - SAF-based optical biosensor with 3D-printed free-form optics for targeted explosives immuno-detection N2 - Guaranteeing safety and security of citizens requires a significant effort and innovative tools from national and international agencies and governments, especially when it comes to the field of explosives detection. The need to detect Improvised Explosive Devices (IEDs) and Home-made Explosives (HMEs) at a point of suspicion, has grown rapidly due to the ease with which the precursors can be obtained and the reagents synthesised. The limited availability of immunoanalytical tools for HME detection presents an opportunity for the development of new devices, which enable a rapid detection and recognise the target analyte with high specificity and sensitivity. In this work, we introduce an optical biosensor for highly specific and sensitive HME detection. The immunoassay system is placed in a hydrogel environment permeable to the analyte and transparent to light interrogating the fluorescently labelled antibodies. The readout of the immunoanalytical system is realized with Supercritical Angle Fluorescence (SAF), an advanced microscopy technique. To accomplish this, we made use of recent, commercial high resolution (< 22 µm) Liquid Crystal Display 3D printers to fabricate a parabolic optical element with high refractive index (RI>1.5) and transmission values (>90%) from photo-resin. Aiming at a new generation of sensors, which not only can meet the requirements of trace detection, but can also be used for substance identification, the combination of immunoanalytical recognition with SAF detection offers a modularity and versatility that is principally well suitable for the measurements of target analytes at trace levels. T2 - 8th International conference in Biosensing Technology CY - Seville, Spain DA - 12.05.2024 KW - 3D printing KW - Biosensor KW - Fluorescence KW - Explosives PY - 2024 AN - OPUS4-60561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Biyikal, Mustafa A1 - Gröninger, Delia A1 - Weller, Michael G. A1 - Martínez Mánez, R. A1 - Rurack, Knut ED - Climent Terol, Estela T1 - Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles N2 - Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed. KW - Multiplexing KW - Explosives detection KW - Gated materials KW - Fluorescence PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-518424 DO - https://doi.org/10.1002/anie.202009000 SN - 1433-7851 SN - 1521-3773 VL - 59 IS - 52 SP - 23862 EP - 23869 PB - Wiley-VCH CY - Weinheim AN - OPUS4-51842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pérez-Padilla, Víctor A1 - Burnage, Samual C. A1 - Wittwer, Philipp A1 - Valderrey, Virginia A1 - Bell, Jérémy A1 - Gawlitza, Kornelia A1 - Rurack, Knut T1 - Detection of Perfluoroalkylic Acids From Water Using a Guanidine-Based Fluorescent Probe and Microfluidic Droplet Extraction N2 - Perfluoroalkylic acids (PFAAs), a subclass of per- and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet-based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation-mediated hydrogen bond-assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid-liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µm, with a dynamic range up to 200 µm for sample volumes <100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses. KW - PFAS KW - Fluorescence KW - Microfluidics KW - Droplet Extraction PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657330 DO - https://doi.org/10.1002/adsr.70145 VL - 5 IS - 3 SP - 1 EP - 13 PB - Wiley-VCH CY - Weinheim AN - OPUS4-65733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -